GSM Smart Switch USER GUIDE

GSM Smart Switch allows switching almost any appliance ON and OFF remotely via
mobile network. It is designed to receive start/stop commands from specially coded
messages or via direct call from a master number. It is capable to store up to 5 master
numbers giving you and your colleagues an opportunity to control a burglar alarm, light
in the office, auto start enabled generator, heaters, water pumps, video and audio
equipment, motorized gates, electric motors and other industrial or household
appliances.
MAKE SURE YOUR GSM SWITCH IS NOT CONNECTED TO ANY POWER SUPPLY!
Now you can Insert SIM card into a corresponded slot as it is shown below:

Plug the GSM Smart Switch into a wall socket or/and connect the corresponded
terminals to a battery power supply (12Vdc).

If your premises dont have mains available please


use 12V car battery or any other 12Vdc power
source.

You may need a wall


socket adapter which
can be purchased at a
local electrical store.
A short initialization time is required (approx. 60 sec) to get the
GSM Switch into network.

Dont try to press any buttons or perform other tasks during this
time.

During initialization time the SIG light is flashing every second until
the GSM Switch is successfully connected to network.
Ones the connection is established the SIG light starts flashing
every 4 sec.

Press the SET button. The STA light starts flashing. Now you have 90 sec to make a call
from your desired master number to a SIM card inserted into GSM Switch. You wont be
charged for this call because the GSM Switch will hang up after recognizing your phone
number which will be safely stored into its memory. Repeat this step if more than one
master number is required to set up. By making a call from a master number to a SIM
card inserted into GSM switch you can switch ON and OFF the GSM Switch internal
relay. Each following call changes the state of internal relay to opposite. The GSM
internal relay has 2 normally open contacts which can be used to connect and
disconnect your load or start and stop a generator for instance. If you have more than
one master number (up to 5 master numbers can be stored), each following call from
ANY master number will change the relay state to opposite.

To be able to use SMS control you would have to set up a user password.
The GSM Switch comes with factory pre-set password 0000 which has to be changed
to your own password which is not easy to guess.
Make sure the GSM Switch is powered on and connected to mobile network:
SIG light is indicating a successful network connection by performing flashing every 4
sec.
Create and send to GSM Switch the following text message:

Where XXXX is your old password and 1234 is your new password.
If successful, you should receive the following confirmation:
Create and send the following message to your GSM Switch:

where 1234 is your current password and 13788889999


is a master number.
If successful, you should receive the following confirmation:

Repeat STEP 6 to create and store another 4 master numbers if required.

Create and send the following text message to your GSM Switch:

To turn ON: where 1234 is your current user password.

If successful, you should receive the following confirmation:

To turn OFF: where 1234 is your current user password.

If successful, you should receive the following confirmation:

There is another useful SMS command available which can tell the GSM switch to
change the current state to opposite: where 1234 is your current
user password.
You can store this message in your mobile phone or your partners mobile phone and
use it every time you need to turn something on or off. Each following message will
change the state of GSM Switch to opposite.
You would only need one message instead of two which is perfect for some people.

Create and send the following SMS to your GSM Switch:

where 1234 is your current user password.


If successful, you should receive one of the following confirmations:

or
The type of confirmation message depends on state your GSM Switch currently at.
Should you require to turn the GSM Switch ON or OFF manually, press and release SW
button. The current state of GSM Switch will be changed to opposite.

Should you require to restore the system back to factory settings press and release
SW and SET buttons at the same time. STA light will flash 2 times indicating a
successful operation. All master numbers will be erased and user password changed
back to 0000.

IMPORTANT!
3G or SDMA card is not supported.
The front mains socket doesnt work as a switch. It only replaces a wall socket the GSM
Switch is plugged in.
This device is designed for Indoor use only!

Specification
Power supply: 110-240Vac and/or 12Vdc
Stand-by current: 15 mA
Working current (relay is ON): 60 mA
Max. switching current: 10A
Max. switching voltage: 277Vac
GSM: 900/1800 MHz
Weight: 145g
Dimensions: L=100mm, W=65mm, H=33mm (exc. mains plug and aux. terminals)