Vous êtes sur la page 1sur 4

Designation: C 125 00

Standard Terminology Relating to


Concrete and Concrete Aggregates1
This standard is issued under the fixed designation C 125; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.

This standard has been approved for use by agencies of the Department of Defense.

1. Scope of concrete or mortar and added to the batch immediately


1.1 The following definitions apply to hydraulic cement before or during its mixing.
concrete, although some of them may have wider application.2 accelerating admixture, nadmixture that accelerates the
setting and early strength development of concrete. (C 494/
2. Referenced Documents 494M)
2.1 ASTM Standards: air-entraining admixture, nadmixture that causes the devel-
C 109/C 109M Test Method for Compressive Strength of opment of a system of microscopic air bubbles in concrete or
Hydraulic Cement Mortars (Using 2in. or 50mm Cube mortar during mixing.
Specimens)3 retarding admixture, nadmixture that retards the setting of
C 143/C 143M Test Method for Slump of Hydraulic Ce- concrete. (C 494/ 494M)
ment Concrete4 water-reducing admixture, nadmixture that either increases
C 403/C 403M Test Method for Time of Setting of Concrete the slump of freshly mixed mortar or concrete without
Mixtures by Penetration Resistance4 increasing the water content or that maintains the slump with
C 494/ 494M Specification for Chemical Admixtures for a reduced amount of water due to factors other than air
Concrete4 entrainment.
C 939 Test Method for Flow of Grout for Preplaced- aggregate, ngranular material, such as sand, gravel, crushed
Aggregate Concrete (Flow Cone Method)4 stone, or iron blast-furnace slag, used with a cementing
C 1074 Practice for Estimating Concrete Strength by the medium to form hydraulic-cement concrete or mortar.
Maturity Method4 coarse aggregate, n(1) aggregate predominantly retained on
the 4.75-mm (No. 4) sieve; or (2) that portion of an
3. Terminology aggregate retained on the 4.75-mm (No. 4) sieve.
absorption, nthe process by which a liquid is drawn into and DISCUSSIONThe definitions are alternatives to be applied under
tends to fill permeable pores in a porous solid body; also, the differing circumstances. Definition (1) is applied to an entire aggregate
increase in mass of a porous solid body resulting from the either in a natural condition or after processing. Definition (2) is applied
to a portion of an aggregate. Requirements for properties and grading
penetration of a liquid into its permeable pores.
should be stated in the specification.
DISCUSSIONIn the case of concrete and concrete aggregates, unless
otherwise stated, the liquid involved is water, the increase in mass is fine aggregate, n(1) aggregate passing the 38-in. (9.5-mm)
that which does not include water adhering to the outside surface, the sieve and almost entirely passing the 4.75-mm (No. 4) sieve
increase in mass is expressed as a percentage of the dry mass of the and predominantly retained on the 75-m (No. 200) sieve; or
body and the body is considered to be dry when it has been treated (2) that portion of an aggregate passing the 4.75-mm (No. 4)
by an appropriate process to remove uncombined water, such as drying sieve and retained on the 75-m (No. 200) sieve.
to constant mass at a temperature between 100 and 110C.
DISCUSSIONThe definitions are alternatives to be applied under
admixture, na material other than water, aggregates, hy- differing circumstances. Definition (1) is applied to an entire aggregate
draulic cement, and fiber reinforcement used as an ingredient either in a natural condition or after processing. Definition (2) is applied
to a portion of an aggregate. Requirements for properties and grading
1
should be stated in the specifications.
This terminology is under the jurisdiction of ASTM Committee C-9 on
Concrete and Concrete Aggregates and is the direct responsibility of Subcommittee heavyweight aggregate, naggregate of high density; such as
C09.91 on Editorial and Terminology.
Current edition approved Jan. 10, 2000. Published March 2000. Originally
barite, magnetite, limonite, ilmenite, iron, or steel.
published as C 125 36 T. Last previous edition C 125 99a. lightweight aggregate, naggregate of low density used to
2
C 219, Terminology Relating to Hydraulic Cement contains definitions of a produce lightweight concrete, including: pumice, scoria,
number of items in use in standards under the jurisdiction of Committee C-9. volcanic cinders, tuff, and diatomite; expanded or sintered
Definitions of additional terms may be found in Cement and Concrete Terminology,
116R American Concrete Institute, P.O. Box 19150, Detroit, MI 48219. clay, shale, slate, diatomaceous shale, perlite, vermiculite, or
3
Annual Book of ASTM Standards, Vol 04.01. slag; and end products of coal or coke combustion.
4
Annual Book of ASTM Standards, Vol 04.02.

Copyright ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.

1
C 125
air-cooled blast-furnace slag, nthe material resulting from DISCUSSIONThis characteristic of fresh cementitious mixtures is
solidification of molten blast-furnace slag under atmospheric difficult to quantify and empirical test methods have been adopted to
conditions; subsequent cooling may be accelerated by appli- provide indicators of consistency. For example, the slump test de-
scribed in Test Method C 143/C 143M is used for concrete, the flow
cation of water to the solidified surface. table method described in Test Method C 109/C 109M is used for
air content, nthe volume of air voids in cement paste, mortar, and the flow cone method described in Test Method C 939 is
mortar, or concrete, exclusive of pore space in aggregate used for grout.
particles, usually expressed as a percentage of total volume
of the paste, mortar, or concrete. crushed gravel, nthe product resulting from the artificial
air void, na space in cement paste, mortar, or concrete filled crushing of gravel with substantially all fragments having at
with air; an entrapped air void is characteristically 1 mm or least one face resulting from fracture.
more in width and irregular in shape; an entrained air void is crushed stone, nthe product resulting from the artificial
typically between 10 and 1000 m in diameter and spherical crushing of rocks, boulders, or large cobblestones, substan-
or nearly so. tially all faces of which have resulted from the crushing
operation.
DISCUSSIONThe content of the voids may include atmospheric air curing, naction taken to maintain moisture and temperature
incorporated into the concrete during mixing of air or other gases conditions in a freshly-placed cementitious mixture to allow
released by chemical or other processes within the fresh concrete.
hydraulic cement hydration and (if applicable) pozzolanic
blast-furnace slag, nthe nonmetallic product, consisting reactions to occur so that the potential properties of the
essentially of silicates and aluminosilicates of calcium and mixture may develop (see ACI 308).
other bases, that is developed in a molten condition simul- curing compound, na liquid that, when applied as a coating
taneously with iron in a blast furnace. to the surface of newly-placed concrete, forms a membrane
bleeding, nthe autogenous flow of mixing water within, or that retards the evaporation of water and, in the case of white
its emergence from, newly placed concrete or mortar caused pigmented compounds, reflects heat (see also curing).
by the settlement of the solid materials within the mass, also D-cracking, nin concrete, a series of cracks near to and
called water gain. roughly parallel to features such as joints, edges, and
bulk density, nof aggregate, the mass of a unit volume of structural cracks.
bulk aggregate material (the unit volume includes the density, nmass per unit volume (preferred over deprecated
volume of the individual particles and the volume of the term unit weight).
voids between the particles). elongated piece (of aggregate), na particle of aggregate for
which the ratio of the length to width of its circumscribing
DISCUSSIONThis term replaces the deprecated term unit weightof
aggregate. rectangular prism is greater than a specified value (see also
flat piece (of aggregate)).
bulk specific gravity, nthe ratio of the mass of a volume of entrained airsee air void.
a material (including the permeable and impermeable voids entrapped airsee air void.
in the material, but excluding the voids between particles of expanded blast-furnace slag, nthe lightweight cellular
the material) at a stated temperature to the mass of an equal material obtained by controlled processing of molten blast-
volume of distilled water at a stated temperature. furnace slag with water or water and other agents, such as
bulk specific gravity (saturated surface dry), nthe ratio of steam or compressed air or both.
the mass of a volume of a material including the mass of fineness modulus, na factor obtained by adding the percent-
water within the pores in the material (but excluding the ages of material in the sample that is coarser than each of the
voids between particles) at a stated temperature, to the mass following sieves (cumulative percentages retained), and
of an equal volume of distilled water at a stated temperature. dividing the sum by 100: 150-m (No. 100), 300-m (No.
cellular concrete, na lightweight hydraulic-cement concrete 50), 600-m (No. 30), 1.18-mm (No. 16), 2.36-mm (No. 8),
having a homogeneous void or cell structure attained using 4.75-mm (No. 4), 9.5-mm (38-in.), 19.0-mm (34-in.),
gas-forming chemicals or foaming agents. 37.5-mm (112-in.), 75-mm (3-in.), 150-mm (6-in.).
cementitious material (hydraulic), nan inorganic material flat piece (of aggregate), na particle of aggregate for which
or a mixture of inorganic materials that sets and develops the ratio of the width to thickness of its circumscribing
strength by chemical reaction with water by formation of rectangular prism is greater than a specified value (see also
hydrates and is capable of doing so under water. elongated piece (of aggregate)).
cementitious mixture, na mixture (mortar, concrete, or fly ash, nthe finely divided residue that results from the
grout) containing hydraulic cement. combustion of ground or powdered coal and that is trans-
concrete, na composite material that consists essentially of ported by flue gases from the combustion zone to the particle
a binding medium within which are embedded particles or removal system.
fragments of aggregate; in hydraulic-cement concrete, the fresh concrete, nconcrete which possesses enough of its
binder is formed from a mixture of hydraulic cement and original workability so that it can be placed and consolidated
water. by the intended methods.
consistency, nof fresh concrete, mortar, or grout, the relative
mobility or ability to flow.

2
C 125
granulated blast-furnace slag, nthe glassy, granular mate- pozzolan, na siliceous or siliceous and aluminous material,
rial formed when molten blast-furnace slag is rapidly chilled, which in itself possesses little or no cementitious value but
as by immersion in water. will, in finely divided form and in the presence of moisture,
gravel, ncoarse aggregate resulting from natural disintegra- chemically react with calcium hydroxide at ordinary tem-
tion and abrasion of rock or processing of weakly bound peratures to form compounds possessing cementitious prop-
conglomerate. erties.
grout, na cementitious mixture, with or without admixtures, relative density, nsee specific gravity
that is used primarily to fill voids. roller-compacted concrete (RCC), nconcrete compacted
grout, hydrauliccement, na grout made with hydraulic while fresh by a roller, often a vibratory roller.
cement. sand, nfine aggregate resulting from natural disintegration
grout (nonshrink), hydraulic-cement, na hydraulic-cement and abrasion of rock or processing of completely friable
grout that produces a volume that, when hardened under sandstone.
stipulated test conditions, is greater than or equal to the segregation, nthe unintentional separation of the constitu-
original installed volume, often used as a transfer medium ents of concrete or particles of an aggregate, causing a lack
between load-bearing members. of uniformity in their distribution.
hydraulic cement, na cement that sets and hardens by setting, nthe process, due to chemical reactions, occurring
chemical reaction with water and is capable of doing so after the addition of mixing water, that results in a gradual
under water. development of rigidity of a cementitious mixture.
laitance, na layer of weak material derived from cementi- shotcrete, na mortar or concrete that is projected pneumati-
tious material and aggregate fines either: 1) carried by cally at high velocity onto a surface.
bleeding to the surface or to internal cavities of freshly drymixture shotcrete, nshotcrete in which most of the
placed concrete, or 2) separated from the concrete and mixing water is added at the nozzle.
deposited on the concrete surface or in internal cavities wetmix shotcrete, nshotcrete in which most of the ingredi-
during placement of concrete under water. ents, including water, are mixed prior to introduction into the
manufactured sand, nfine aggregate produced by crushing delivery hose.
rock, gravel, iron blast-furnace slag, or hydraulic-cement specific gravity, nthe ratio of mass of a volume of a material
concrete. at a stated temperature to the mass of the same volume of
maturity, nthe extent of the development of a property of a distilled water at a stated temperature.
cementitious mixture. time of setting, nthe elapsed time from the addition of
DISCUSSIONThis term is usually used to describe the extent of
mixing water to a cementitious mixture until the mixture
relative strength development of concrete. However, the term can also reaches a specified degree of rigidity as measured by a
be applied to the evolution of other properties which are dependent on specific procedure.
the chemical reactions which occur in the cementitious materials. At
DISCUSSIONDevelopment of rigidity during setting is a gradual and
any age, maturity is dependent on the curing history.
continuous process, and the time of setting is defined arbitrarily in
maturity function, na mathematical expression which uses terms of a given test method. For cementitious mixtures, time of setting
the measured temperature history of a cementitious mixture is usually defined as the elapsed time to attain a specified level of
resistance to penetration by a probe. For example, the time of initial
during the curing period to calculate an index that is setting of concrete is determined by Test Method C 403/C 403M and is
indicative of the maturity at the end of that period. defined as the elapsed time, after initial contact of cement and water, for
maturity index, nan indicator of maturity which is calcu- the mortar sieved from the concrete to reach a penetration resistance of
lated from the temperature history of the cementitious 500 psi (3.5 MPa).
mixture by using a maturity function.
time of final setting (of concrete), nthe elapsed time, after
DISCUSSIONThe calculated index is indicative of maturity provided initial contact of cement and water, required for the mortar
there has been a sufficient supply of water for hydration or pozzolanic sieved from the concrete to reach a penetration resistance of
reaction of the cementitious materials during the time interval used in 4000 psi (27.6 MPa). (C 403/C 403M).
the calculation. Two widely used maturity indexes are the temperature-
time factor and the equivalent age. See Practice C 1074.
time of initial setting (of concrete), nthe elapsed time, after
initial contact of cement and water, required for the mortar
minimum size (of aggregate), nin specifications for, or sieved from the concrete to reach a penetration resistance of
description of aggregate, the smallest sieve opening through 500 psi (3.5 MPa). (C 403/C 403M)
which the entire amount of aggregate is required to pass. unit weight, nof aggregate, mass per unit volume. (Depre-
nominal maximum size (of aggregate), nin specifications cated termuse preferred term bulk density).
for, or description of aggregate, the smallest sieve opening water-cement ratio, nthe ratio of the mass of water,
through which the entire amount of the aggregate is permit- exclusive only of that absorbed by the aggregates, to the
ted to pass. mass of portland cement in concrete, mortar, or grout, stated
DISCUSSIONSpecifications on aggregates usually stipulate a sieve as a decimal.
opening through which all of the aggregate may, but need not, pass so DISCUSSIONThis term, abbreviated as w/c, is applicable only to
that a stated maximum proportion of the aggregate may be retained on cementitious mixtures in which the only cementitious material is
that sieve. A sieve opening so designated is the nominal maximum size
of the aggregate.

3
C 125
portland cement. For cementitious mixtures containing blended hydrau- cementitious mixtures which contain cementitious material other than
lic cement, or a combination of portland cement and separate addition just portland cement, such as a blended hydraulic cement, or a
of another cementitious material (such as a pozzolan), use the term combination of portland cement and separate addition of another
water-cementitious material ratio. cementitious material (such as a pozzolan). When portland cement is
the only cementitious material contained in the cementitious mixture,
water-cementitious material ratio, nthe ratio of the mass use the term water-cement ratio.
of water, exclusive only of that absorbed by the aggregates,
to the mass of cementitious material (hydraulic) in concrete, workability of concrete, nthat property determining the
mortar, or grout, stated as a decimal (see also water-cement effort required to manipulate a freshly mixed quantity of
ratio). concrete with minimum loss of homogeneity.
DISCUSSIONThis term, abbreviated as w/cm, is applicable only to

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible
technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your
views known to the ASTM Committee on Standards, at the address shown below.

This standard is copyrighted by ASTM, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at
610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (www.astm.org).

Vous aimerez peut-être aussi