Vous êtes sur la page 1sur 77

CHAPTER-5

SYNCHRONOUS MACHINES
The synchronous electrical generator (also called
alternator) belongs to the family of electric rotating
machines.
Other members of the family are the direct current(dc)
motor or generator, the induction motor or generator,
and a number of derivatives of all these three.
What is common to all the members of this family is
that the basic physical process involved in their
operation is the conversion of electromagnetic energy to
mechanical energy, and vice versa.
1
Cont
A.C generators or alternators(as they are called)
operate on the same fundamental principle of
electromagnetic induction as d.c generators.
They also consists of armature winding and
magnetic field winding.
In their case standard construction consists of
armature winding mounted on stationary element
called stator and field windings on rotating
element called rotor.

2
Advantage of stationary armature(AC generator)
The out put current can be led to directly from fixed
terminals on the stator(or armature winding)to the
load circuit with out having to pass it through brush
contact.
It is easer to insulate stationary armature winding for
high a.c voltage which may have a high a value as
30kv or more.
Saving space and weight.
Because the output windings are now stationary
they are no longer subject to high centrifugal
forces and can therefore be larger.

3
Cont
By having the output windings on the outside of the
machine there is more room for good insulation and
higher voltages can be used.
With the output windings on the outside of
the machine they are more easily cooled and
can therefore carry larger currents.
These advantages mean a larger
output can be obtained from a
smaller machine.

4
Description of AC Generators
A generator which produces alternating
current is called an ac generator.
Currently the term ALTERNATOR is
widely used in place of ac generator.
The term alternator is obtained by
combining parts of the two words
alternating and generator.
Usually the word alternator is used for
small ac generators.

5
Similarities Between an Alternator & a DC Generator
Both, alternators and dc generators, have rotating
parts and stationary parts.
Both convert mechanical energy into electrical energy
Difference Between an Alternator & a DC Generator
Alternator DC generator
Has rotating field and Has rotating armature and
stationary armature. stationary field.
Output is taken from the Output is taken from the
stationary part(armature). rotating part (armature).
Brushes and commutators Brushes and commutators
are not required. are used to collect the output

6
Principle of Operation
The operation of a synchronous generator is based on
Faraday's law of electromagnetic induction, and in an
ac synchronous generator the generation of emf's is
by relative motion of conductors and magnetic flux.
These machines can be used as either motors or
generators but their predominant use is in generation.
There are a number of sources of energy used to turn
the turbines:-
(a) Gas (b) Steam
(c) Combined cycle (d) Nuclear
(e) Hydro (f) Wind
(g) Wave (h) Photovoltaic
7
Principle of Operation
In constructing a synchronous machine a point to note is that the stator
is fixed and the poles rotate.
There are two categories of Synchronous machines:
(1) Those with cylindrical rotors
(2)Those with salient or projecting poles

8
Principle of Operation

9
Principle of Operation
Its characteristic feature is
that the armature rotates
through a stationary magnetic
field, and the generated AC is
brought to the load by means
of slip rings and brushes.
The revolving-armature
alternator is found only in
alternators of small power
rating and is not generally
used. This is because a
rotating armature requires slip
rings and brushes to conduct
the current from the armature
to the load.

10
Principle of Operation
The revolving-field type
alternator has a stationary
armature and a rotating
magnetic field.
The generated voltage can be
connected directly to the load
without having to pass across
the slip rings and brushes.
The voltage applied to
generate the rotating field is a
small DC voltage (called a
field excitation voltage)

11
TYPES OF ALTERNATORS
Alternators may be classified according to their field
excitation as:-
- Direct connected direct current generator
- Transformation and rectification from the ac system.
- Integrated brushless type.
Another type of classification is based on the type of rotor
and stator used.
1. The revolving armature
- Is similar to the dc generator.
- It uses brushes and slip rings.
2. The revolving field
- Output is taken from the stator
- No slip rings and brushes are
required.

12
Still another type of classification is based on the
number of phases
Single phase alternator
Two phase alternator
Three phase alternator
Single Phase Alternators
Based on the number of poles, two or more
windings are connected in series.
The coils are connected in series in such a manner
that the voltages add up.
This type of alternator doesnt have wide practical
application.

13
Single Phase Alternators

A single-phase alternator has all the


armature conductors connected in series

The stator is two pole. The winding is


wound in two distinct pole groups, both
poles being wound in the same direction
around the stator frame

The rotor also consists of two


pole groups, adjacent poles being
of opposite polarity

14
Single Phase Alternators

The two poles of the stator winding


are connected to each other so that the
AC voltages are in phase, so they add.

As the rotor (field) turns, its poles will induce AC


voltages in the stator (armature) windings. Since one
rotor pole is in the same position relative to a stator pole
as any other rotor pole, both the stator poles are cut by
equal amounts of magnetic lines of force at any time. As
a result, the voltages induced in the two poles of the
stator winding have the same amplitude or value at any
given instant. 15
Cont

16
Two Phase Alternators
It has two single phase windings which are
insulated from each other.
The windings are physically displaced 900 apart.
When one winding cuts maximum flux, the other
cuts no flux.
Thus, the output voltage will have 900 phase
difference

17
Three Phase Alternators
This is the most widely used VB

type of a/c alternators.


120O VA
It has three single phase 120O
120O
windings which are physically
displaced 1200. VC

The voltage waveforms A B C


V
generated across each phase O
are drawn on a graph phase- L
displaced 120 degrees from T
each other. A
G
E

18
Three Phase Alternators
Generation of ac is based on the principles of
electromagnetic induction.
A conductor is placed in varying magnetic field.
The magnetic field can be obtained either from a
permanent magnet or an electromagnet.
The output voltage is of sinusoidal waveform
The a/c alternator is a three phase unit.
It has three single windings on the stator.
The field (rotating part) is called the rotor.
Ac generators can have two or more number of poles.

19
Three Phase Alternators with three phase load

In both cases the output waveform and frequency remain the same

20
Three Phase Alternators
The three phases are independent of each other.
One point from each winding can be connected to form
a neutral and thus make a wye connection.
The voltage from this point to any one of the line leads
will be the phase voltage. The line voltage across any
two line leads is the vector sum of the individual phase
voltages. The line voltage is 1.73, (3 ), times the phase
voltage.
Since the windings form only one path for current flow
between phases, the line and phase currents are equal.
The wye connection supplies increased line voltage at a
value of line current equal to phase current.

21
Three Phase Alternators
A three-phase stator can also be connected so that the
phases form a delta connection.
In the delta connection the line voltages are equal to
the phase voltages, but the line currents will be equal
to the vector sum of the phase currents.
Since the phases are 120 degrees out of phase, the
line current will be 1.73, (3 ), times the phase
current. Both "wye" and the "delta" connections are
used in alternators.
For equal output power, the delta connection supplies
increased line current at a value of line voltage equal
to phase voltage. 22
THREE PHASE ALTERNATORS
The stator winding can be connected either in WYE or
DELTA
A
WYE CONNECTION
B
VL = 1.73VPH C

I L = IPH
Three Phase STAR
DELTA CONNECTION Connected

VL = VPH
IL = 1.73IPH A

PH = PHASE VALUE
C B
L = LINE VALUE
Three Phase
DELTA Connected

23
Three Phase Alternators
The frequency of the AC generated by an alternator depends
upon the number of poles and the speed of the rotor.
When a rotor has rotated through an angle so that two
adjacent rotor poles (a north and a south) have passed one
winding, the voltage induced in that one winding will have
varied through a complete cycle of 360 electrical degrees.
A two pole machine must rotate at twice the speed of a four-
pole machine to generate the same frequency.
The magnitude of the voltage generated by an alternator can
be varied by adjusting the current on the rotor which
changes the strength of the magnetic field

24
Three Phase Alternators
A two pole alternator produces one electrical cycle for
each complete mechanical rotation.
A four pole alternator will produce two electrical cycles
for each mechanical rotation because two north and two
south poles move by each winding on the stator for one
complete revolution of the rotor.
f = (nRotor)(p/2)/60 = (nRotorp)/120
where nRotor is the speed of the rotor in revolutions per
minute, p- is the number of poles, f -is the electrical line
frequency produced by the alternator.

25
Three Phase Alternators
The speed of the rotor must be divided by 60 to change
from revolutions per minute to revolutions per second

26
Three Phase Alternators
In an alternator the output voltage varies with the load.
There are two voltage drops.{ IR & IXL }.
The IXL drop is due to the inductive reactance of the
armature windings.
Both the IR drop and the IXL drop decrease the output
voltage as the load increases.
The change in voltage from no-load to full-load is called
the voltage regulation of an alternator.
A constant voltage output from an alternator is
maintained by varying the field strength as required by
changes in load.
27
AC Generators Construction

Parts of AC Generators
Main Generator
Pilot Exciter
Exciter Generator

28
Generally a synchronous generator must have at least 2
components:
a) Rotor Windings or Field Windings
- Salient Pole
- Non Salient Pole
b) Stator Windings or Armature Windings
The rotor of a synchronous generator is a large
electromagnet and the magnetic poles on the rotor can
either be salient or non salient construction.
Non-salient pole rotors are normally used for rotors with
2 or 4 poles rotor, while salient pole rotors are used for 4
or more poles rotor.

29
Cont

30
Cont
A dc current must be supplied to the field circuit on the
rotor. Since the rotor is rotating, a special arrangement
is required to get the dc power to its field windings.
The common ways are:
a) supply the dc power from an external dc source to
the rotor by means of slip rings and brushes.
b) Supply the dc power from a special dc power
source mounted directly on the shaft of the
synchronous generator.

31
Cont
Some problems with slip rings and brushes:
- They increase the amount of maintenance required
on the machine, since the brushes must be checked
for wear regularly.
- Brush voltage drop can be the cause of significant
power losses on machines with larger field currents.
Small synchronous machines use slip rings and
brushes.
Larger machines brushless exciters are used to
supply the dc field current

32
A brushless exciter
Is a small ac generator with its field circuit mounted on
the stator and its armature circuit mounted on the rotor
shaft.
The 3-phase output of the exciter generator is rectified
to direct current by a 3-phase rectifier circuit also
mounted on the shaft of the generator, and is then fed to
the main dc field circuit.
By controlling the small dc field current of the exciter
generator (located on the stator), we can adjust the field
current on the main machine without slip rings and
brushes.
Since no mechanical contacts occur between the rotor
and stator, a brushless exciter requires less maintenance.
33
A brushless exciter

34
A brushless exciter
A brushless exciter circuit : A small 3-phase current is
rectified and used to supply the field circuit of the
exciter, which is located on the stator. The output of
the armature circuit of the exciter (on the rotor) is
then rectified and used to supply the field current of
the main machine.
To make the excitation of a generator completely
independent of any external power sources, a small
pilot exciter can be used.

35
Pilot exciter
A pilot exciter is a small ac generator with permanent
magnets mounted on the rotor shaft and a 3-phase
winding on the stator.
It produces the power for the field circuit of the
exciter, which in turn controls the field circuit of the
main machine.
If a pilot exciter is included on the generator shaft,
then no external electric power is required.

36
Pilot exciter

37
The Speed of Rotation of a Synchronous Generator
Synchronous generators are by definition
synchronous, meaning that the electrical frequency
produced is locked in or synchronized with the
mechanical rate of rotation of the generator.
A synchronous generators rotor consists of an
electromagnet to which direct current is supplied.
The rotors magnetic field points in the direction the
rotor is turned.
Hence, the rate of rotation of the magnetic field in the
machine is related to the stator electrical frequency
by:
fe=Nm P
120 38
39
40
41
Armature Reaction
effect of armature (stator) flux on the flux produced by the rotor field poles is called
armature reaction.
It has two undesirable effects, either it distorts the main field or it reduces the main
field flux or both.

When the field gets distorted, it is known as cross magnetizing effect. and when the field
flux gets reduced, it is known as demagnetizing effect.

In an alternator like all other synchronous machines, the effect of armature reaction
depends on the power factor

the phase relationship between the terminal voltage and armature current.
Reactive power (lagging) is the magnetic field energy, so if the generator
supplies a lagging load, this implies that it is supplying magnetic energy to
the load. Since this power comes from excitation of synchronous machine,
the net reactive power gets reduced in the generator. Hence, the armature
reaction is demagnetizing in nature.

Similarly, the armature reaction has magnetizing effect when the generator supplies
a leading load (as leading load takes the leading VAR ) and in return gives lagging
VAR (magnetic energy) to the generator.
In case of purely resistive load, the armature reaction is cross magnetizing only. 42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
Power and Torque in Synchronous Generators
A generator converts mechanical energy
into electrical energy, hence the input
power will be a mechanical prime mover,
e.g. diesel engine, steam turbine, water
turbine or anything similar.
Regardless of the type of prime mover,
the rotor velocity must remain constant
to maintain a stable system frequency.

60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
When ac generators operate in parallel:-
The phase sequence of the generators must be the
same.
The output voltage of each generator must be equal.
The output frequency of the generators must be equal.
Reasons for operating in parallel:
a) Handling larger loads.
b) Maintenance can be done without power disruption.
c) Increasing system reliability.
d) Increased efficiency.

76
THANK YOU !!

77

Vous aimerez peut-être aussi