1 2 3 4 5 6 7 8 9

-QF1.4
A

Un [V] 400
LLLN / TN-S
Ik LLL [kA] 42.3
Ik LN [kA] 25.4

Ik LPE [kA] 25.4
B P [kW] 977.5
Q [kvar] 605.8


-QF1.2 -QF1.7


M M

E Descripcion
Carga

Voltaje [V] dV % 400 0.81 400 0.77

(!) Important notice about coordination to be verified in Discrimination report


Potencia Activa [kW] UF % 505.00 100 405.00 100
Ir [A] Cosphi 912.3 0.86 747.5 0.86
Fabricante ABB ABB ABB

(*) El interruptor automtico es selectivo con otro insterruptores.


Circuit breaker/Disconnector T7S 1000 PR231-LS/I 1000A T8L 2000 PR332-LI 2000A T7S 800 PR231-LS/I 800A
ComandO / proteccin

(**) El interruptor tiene back-up con otros interruptores.


Polos In [A] 4P 1000 4P 2000 4P 800
Ith [A] Idn [A] 920.0 1660.0 768.0
Im [A] Icu/Icn [kA] 4500.0 50.0 8000.0 85.0 3600.0 50.0
F Fusible Tamao [A]
Contactor In [A]
Contactor In [A]
Rel de sobrecarga Configuracin [A]
Tipo de cable Cu-PVC Cu-PVC Cu-PVC
Lnea de Distribucin

Seccin 3x 5G300/150 9x(1x630)+3x(1x400)+3G400 3x 5G240/120


Longitud (m) [m] Iz [A] 50 1222.6 10 2226.3 50 1057.8
Ib L1 [A] Nm. instalacin 912.3 13 1659.8 13 747.5 13
Ib L2 [A] dV % 912.3 0.64 1659.8 0.17 747.5 0.60
Ib L3 [A] Ik mn [kA] 912.3 8.70 1659.8 18.50 747.5 7.91
Ib N [A] Ik mx [kA] 0.0 44.98 0.0 42.34 0.0 46.07
G
Rev. n1 Fecha: Descripcion Cliente: Numero de Dibujo:
Rev. n2 Dibujante: Proyecto: ejercicio 4
Rev. n3 Diseador: Archivo: Pgina: Siguiente pgina: Pginas:
REVISIONES Fecha: Firmas Aprobador: Serie: 1 1
1 2 3 4 5 6 7 8 9