DIN Rail Mounting Power Supply


Operation Manual P.1
Industrial Power Supply 20W - 48W (Plastic Housing, Single Output) P.2
40W - 60W (Metal Housing, Single and Dual Output) P.3
72W - 100W (Metal Housing, Single and Dual Output) P.4
120W - 150W (Metal Housing, Single and Dual Output) P.5
240W - 360W (Metal Housing, Single and Dual Output) P.6
240W (Metal Housing, Single and Dual Output, Active PFC) P.7
360W (Metal Housing, Single and Dual Output, Active PFC) P.8
500W (Metal Housing, Single and Dual Output) P.9
DC Motor Power Supply 100W (Metal Housing, Single and Dual Output) P.10
150W (Metal Housing, Single and Dual Output) P.11
240W (Metal Housing, Single and Dual Output) P.12
500W (Metal Housing, Single Output) P.13
Battery Charger 72W (Metal Housing, Single Output) P.14
120W (Metal Housing, Single Output) P.15
72W (Metal Housing, Single Output with Alarm Signal) P.16
120W (Metal Housing, Single Output with Alarm Signal) P.17
Lead - Acid Battery Charger
60W (Plastic Housing, 3-Stage Charging Control) P.18
90W (Plastic Housing, Built-in MCU) P.19
150W (Metal Housing, 3-Stage Charging Control) P.20
150W (Plastic Housing, Built-in MCU) P.21
150W (Anodized Aluminum Housing, Built-in MCU) P.22
240W (Anodized Aluminum Housing, Built-in MCU) P.23
360W - 500W (Metal Housing, Built-in MCU) P.24
Company Profile
To be a satisfactory partner of the field of electronic industry is the vision of Acro Engineering Inc. We integrated an
excellent factory area, talented R&D and experienced QC engineer to establish Acro in 2005. The cadre members
have been dedicated in switching mode power supply for more than 20 years, and experienced diverse application
of switching mode power supply. Via their excellent expertise and sincerity service, the perfect team is dedicated
to provide best service to the international customers with quality products that are reliable, cost effective and on
time delivery. Based on the strong organization, Acro has built hundreds standard model and cooperated to many
customers' design project, and get extreme satisfation from our customers.
Developed standard products - DIN rail power supplies. Implemented RoHS compliance and CE declaration.
2005 Conduct green mode concept and announced quasi-resonent product.
Cooperated with EPS to develop smart battery charger for electric vehicle that proceed charging procedure by
2006 MCU. And supply lead-acid battery charger to Australia army.
Acquired CE and CB report for DIN rail power supply, and TUV certificate for specific models.
Developed power supply for LED pedestrian traffic count down system.
Developed constant current control LED power supply for office and street lighting.
2007 Built distribution network that include Taiwan, Spain, Italy, Israel, Iran, Turkey, South Africa, Germany, Peru,
India and UK.
Successfully develop and production back-up power device for Bosch Security System.
Launched new DIN rail power supplies for DC motor with high peak current and CEMF damper.
2008 Partner with AccuTherm to develop smart battery charger for electric tool that charging NiCD, NiMH and LI-ion
Battery automatically.
Develop power supply for elevator which with wide input range 170 - 528VAC.
60 DIN rail models Acquired UL508 approval..
2009 Successfully design and manufacture IP 67 power supply for LED contour lighting of Taipei building.
Developed constant current power supply with single stage active PFC.
Distribution network extend to Russia, Thailand, Malaysia, South Korea and China..
2010 Develop and manufacture power supply for LED traffic lamp and count down system.
Successfully design IP54 power supply for electric tool, and having UL certificate.
Developed power supply with battery backup & charging function for security system ranged from 60W to 150W.
2011 Develop battery charger for LiFePO4 ranged from 150W to 500W.
DIN Rail Mounting Power Supply
Operation Manual
Product description
The DIN rail power supplies are designed to snap-on TS-35 DIN rail and wall bracket mounting. They are ideal for use in
control system, factory automation, industrial control, instrumentation, electromagnetic drivers and other DC load. The models
are designed according to the latest requirement and standard that CE marking and RoHS compliance. Build-in dry contact
relay and O-ring diode to offer Rdy signal (Alarm) and redundant application. Complete protection include over voltage,
overload and short circuit to avoid damage at wrong operation.
Terminal allocation Rdy & Redundant connection
24VDC 3A Designation Description +
AD1072-24FR
I/P:100~240VAC +
47~63Hz 1.5A Max.

DC OK
DC OK Green LED Indicator PSU -
Rdy
V Adj. V Adj. O/P Voltage adjustment
input of device

+ + Output Positive
-
- Output Negative
Rdy
Rdy DC OK signal (Short)
+
-
-
PSU
Earth Rdy
N input of device

L N Input Neutral
P.S. Please adjust output voltage of each unit
L Input Line as close as possible to balance the loading.

Model No. Description AD 1 072 - 24 F R


Family ..................................................................AD (DIN rail)
Number of Output.................................................1 (single)
Rated Output Wattage..........................................072 (72W)
Rated Output Voltage........................................24 (24VDC)
Input Voltage Range................................F (100~240VAC)
S (115/230VAC selectable)
Redundant & Rdy function....................................................R

Installation Instruction
1. Making sure wire connection of the designations and input selector are correct before turn on AC source. AC input selector is
located at left (Fig. 1) of front panel of AD1vvv-xyS models. The connector can withstand 8 lb-in torque Maximum and use
o o
copper connectors only, 60/75 C and installation in Pollution Degree 2 environment. Max. surrounding air temperature 40 C .
2. Snap power unit on TS35 DIN rail, please operate as Fig. 2. Using a "-" screw driver to pull down underside mounting bracket
to release power unit from TS35 DIN rail.
3. The left housing of power unit is design as heatsink, please keep 15mm Min. for dissipating heating. (Fig. 1)
4. For mounting power unit by mounting bracket, please loosen screws on mounting bracket
and pull both brackets outer. And then re-screw the mounting brackets to get easier operation
of mounting on wall/plate. (Fig. 3)
5. Output voltage adjustable range is +/-10% of rated voltage, over +10% might cause
over voltage protection, under - 10% might cause output flicking at lower loading.
15mm

72W 72W

DC OK DC OK

V.Adj. V.Adj.

+ +
_ _
Rdy Rdy

N N
L L
220

AC Input selector Fig. 3 Fig. 2


Fig. 1

P.1
DIN Rail Mounting Power Supply
3.5
61
8

29

DC OK

V.Adj.

INPUT
Input voltage ..............100~240VAC/120~370VDC
+
_
Input frequency........................................47~63Hz 90
Inrush current ...................................22A/115VAC
(Cold start) 44A/230VAC N
L
OUTPUT
Hold-up time (Full load@230VAC) .....20mS Min.
Over voltage protection ...................Autorecovery
Overload protection ........................Power limited
Short circuit protection ....................Autorecovery
3
Dimensions:75(D)x96(H)x45(W)mm
AD1024F Series Single output
O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

AD1020-05F _10%
+5VDC + 0A 4.0A 4.0A 50mVp-p _ 1%
+ _ 1%
+ 78% 7VDC Max. None None Yes Yes Yes
_10%
AD1024-12F +12VDC + 0A 2.0A 2.0A 100mVp-p _ 1%
+ _ 1%
+ 80% 20VDC Max. None None Yes Yes Yes

AD1024-24F _10%
+24VDC + 0A 1.0A 1.0A 150mVp-p _ 1%
+ _ 1%
+ 83% 40VDC Max. None None Yes Yes Yes

AD1048FS Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

_ 10%
AD1048-12FS +12VDC+ 0A 4.0A 4.0A 100mVp-p _ 1%
+ _ 1%
+ 80% 20VDC Max. None None Yes Yes Yes
_ 10%
AD1048-15FS +15VDC+ 0A 3.0A 3.0A 150mVp-p _ 1%
+ _ 1%
+ 80% 20VDC Max. None 300pcs Yes Yes Yes
_10%
AD1048-24FS +24VDC+ 0A 2.0A 2.0A 150mVp-p _ 1%
+ _ 1%
+ 83% 40VDC Max. None None Yes Yes Yes
_10%
AD1048-48FS +48VDC+ 0A 1.0A 1.0A 250mVp-p _ 1%
+ _ 1%
+ 83% 60VDC Max. None 300pcs None None None

NOTE: 1. Each output is designed to supply up to Max. current, but total loading must be limited within rated output wattage.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 230VAC input.
4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic
capacitor parallel on the test point, at rated load and 230VAC input.
5. Efficiency is measured at rated load and 230VAC input.

P.2
DIN Rail Mounting Power Supply

111

40

48W

DC OK

V.Adj.

+
_
INPUT 110
Input voltage ..............100~240VAC/120~370VDC Rdy
Input frequency........................................47~63Hz
Inrush current ....................................22A/115VAC
(Cold start) 44A/230VAC N
L
OUTPUT
Hold-up time (Full load@230VAC) ......20mS Min.
Over voltage protection ....................Autorecovery 11 110
Overload protection .........................Power limited
Short circuit protection .....................Autorecovery
Dimensions:121(D)x110(H)x40(W)mm
AD1048F Series Single output
O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

AD1040-05F +5VDC +_ 10% 0A 8.0A 8.0A 50mVp-p +_ 1% +_ 1% 78% 7VDC Max. Option None Yes None None
AD1048-12F +12VDC +_ 10% 0A 4.0A 4.0A 100mVp-p +_ 1% +_ 1% 80% 17VDC Max. Option None Yes Yes None
AD1048-24F +24VDC +_ 10% 0A 2.0A 2.0A 150mVp-p +_ 1% +_ 1% 83% 30VDC Max. Option None Yes Yes None

AD1060F Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

AD1060-24F +24VDC +_ 10% 0A 2.5A 2.5A 150mVp-p +_ 1% +_ 1% 83% 30VDC Max. Option None None None None

AD2060F Series Dual output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

+5VDC +_10% 0A 4.0A 5.0A 60mVp-p +_ 2% +_ 2% 7VDC Max.


AD20601F 77% None 200pcs None None None
+12VDC ------ 0A 3.0A 3.0A 150mVp-p +_ 6% +_ 6% --------
+5VDC +_10% 0A 2.0A 5.0A 60mVp-p +_ 2% +_ 2% 7VDC Max.
AD20602F +_ 6% 80% None None None None None
+24VDC ------ 0A 2.0A 2.0A 150mVp-p +_ 6% --------
+12VDC +_10% 0A 2.0A 4.0A 100mVp-p +_ 2% +_ 2% 17VDC Max.
AD20603F 81% None 200pcs None None None
+24VDC ------ 0A 1.5A 2.0A 150mVp-p +_ 6% +_ 6% --------

P.3
DIN Rail Mounting Power Supply

111

56

72W

DC OK

V.Adj.

INPUT
+
Input voltage ..............100~240VAC/120~370VDC _
Input frequency........................................47~63Hz 110
Inrush current ....................................22A/115VAC Rdy
(Cold start) 44A/230VAC

OUTPUT N
L
Hold-up time (Full load@230VAC) ......20mS Min.
Over voltage protection ....................Autorecovery
Overload protection .........................Power limited
Short circuit protection .....................Autorecovery 11 110

Dimensions:121(D)x110(H)x56(W)mm

AD1072F Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

AD1072-12F _ 10%
+12VDC+ 0A 6.0A 6.0A 100mVp-p +_ 1% +_ 1% 78% 17VDC Max. Option None Yes Yes None
AD1072-24F _ 10%
+24VDC+ 0A 3.0A 3.0A 150mVp-p +_ 1% +_ 1% 81% 30VDC Max. Option None Yes Yes None
AD1072-48F _ 10%
+48VDC+ 0A 1.5A 1.5A 250mVp-p +_ 1% +_ 1% 82% 56VDC Max. Option None Yes None None

AD1100F Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

AD1100-12F _ 10%
+12VDC+ 0A 8.0A 8.0A 100mVp-p +_ 1% +_ 1% 78% 17VDC Max. Option None Yes Yes None
AD1100-24F _ 10%
+24VDC+ 0A 4.0A 4.0A 150mVp-p +_ 1% +_ 1% 81% 30VDC Max. Option None Yes Yes None
AD1100-48F _ 10%
+48VDC+ 0A 2.0A 2.0A 250mVp-p +_ 1% +_ 1% 82% 56VDC Max. Option None Yes None None

AD2100F Series Dual output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

AD21001F
+12VDC 10% 0A 7.0A 7.0A 100mVp-p +_ 1% +_ 2% 77%
17VDC Max.
None 200pcs None None None
+5VDC ------ 0A 3.0A 3.0A 60mVp-p +_ 2% +_ 2% -------
+24VDC 10% 0A 3.5A 3.5A 150mVp-p +_ 1% +_ 2% 30VDC Max.
AD21002F 80% None None None None None
+5VDC ------- 0A 3.0A 3.0A 60mVp-p +_ 2% +_ 2% -------

P.4
DIN Rail Mounting Power Supply

111

75

120W

DC OK

INPUT V.Adj.

Input voltage ..............100~240VAC/120~370VDC +


Input frequency........................................47~63Hz _
Inrush current ....................................22A/115VAC 110
Rdy
(Cold start) 44A/230VAC

N
OUTPUT
L
Hold-up time (Full load@230VAC) ......20mS Min.
Over voltage protection ....................Autorecovery
Overload protection .........................Power limited
Short circuit protection .....................Autorecovery 11 110

Dimensions:121(D)x110(H)x75(W)mm

AD1120F Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function
AD1120-12F +12VDC10% 0A 10A 10A 100mVp-p 1% 1% 81% 17VDC Max. Option None Yes Yes None
AD1120-24F +24VDC10% 0A 5A 5A 150mVp-p 1% 1% 83% 30VDC Max. Option None Yes Yes None
AD1120-48F +48VDC10% 0A 2.5A 2.5A 250mVp-p 1% 1% 84% 56VDC Max. Option None Yes Yes None

AD1150F Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function
AD1150-12F +12VDC10% 0A 12.5A 12.5A 100mVp-p 1% 1% 80% 17VDC Max. Option None Yes Yes None
AD1150-24F +24VDC10% 0A 6.3A 6.3A 150mVp-p 1% 1% 82% 30VDC Max. Option None Yes Yes None
AD1150-48F +48VDC10% 0A 3.2A 3.2A 250mVp-p 1% 1% 83% 56VDC Max. Option None Yes Yes None

AD2150F Series Dual output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

+12VDC10% 0A 11A 11A 100mVp-p 1% 2% 17VDC Max.


AD21501F 80% None 200pcs None None None
+5VDC ------ 0A 3A 5A 60mVp-p 2% 2% -------
+24VDC10% 0A 5.5A 5.5A 150mVp-p 1% 2% 30VDC Max.
AD21502F 82% None None None None None
+5VDC ------ 0A 3A 5A 60mVp-p 2% 2% -------

P.5
DIN Rail Mounting Power Supply

111

75

240W

DC OK

V.Adj.
INPUT
Input voltage ....................115/230VAC selectable +
_
Input frequency........................................47~63Hz 110
Inrush current ...................................22A/115VAC Rdy

(Cold start) 44A/230VAC


N
OUTPUT 230
L
Hold-up time (Full load@230VAC) .....20mS Min.
Over voltage protection ...................Autorecovery
Overload protection ........................Power limited 11 110
Short circuit protection ....................Autorecovery
Dimensions:121(D)x110(H)x75(W)mm
AD1240S Series Single output
O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

AD1240-12S +12VDC10% 0A 20A 20A 100mVp-p 1% 1% 80% 17VDC Max. Option None Yes Yes None
AD1240-24S +24VDC10% 0A 10A 10A 150mVp-p 1% 1% 82% 30VDC Max. Option None Yes Yes None
AD1240-48S +48VDC10% 0A 5A 5A 250mVp-p 1% 1% 82% 56VDC Max. Option None Yes Yes None

AD1360S Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

AD1360-24S +24VDC10% 0A 15A 15A 150mVp-p 1% 1% 82% 30VDC Max. Option None None Yes None
AD1360-48S +48VDC10% 0A 7.5A 7.5A 250mVp-p 1% 1% 82% 56VDC Max. Option None None None None

AD2240S Series Dual output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Function

+24VDC10% 0A 9A 9A 150mVp-p 1% 2% 30VDC Max.


AD22402S 82% None 200pcs None None None
+5VDC ------ 0A 3A 3A 60mVp-p 2% 2% -------
+48VDC10% 0A 4.5A 4.5A 250mVp-p 1% 2% 56VDC Max.
AD22403S 82% None 200pcs None None None
+5VDC ------ 0A 3A 3A 60mVp-p 2% 2% -------

P.6
DIN Rail Mounting Power Supply
111

100

240W

INPUT L DC OK

Input voltage ..............100~240VAC/120~370VDC N V Adj.

Input frequency........................................47~63Hz
Inrush current ....................................22A/115VAC Rdy

(Cold start) 44A/230VAC NC 110


Active PFC ...............................................PF>0.94 _
_
OUTPUT +
+
Hold-up time (Full load@230VAC) ......20mS Min.
Over voltage protection ....................Autorecovery
Overload protection .........................Power limited 11 110
Short circuit protection .....................Autorecovery
Dimensions:121(D)x110(H)x100(W)mm

AD1240C Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant MOQ
Model Eff. O.V.P. CB UL TUV
Adjustment Min. Rated Max. Noise Reg. Reg. Function

AD1240-12C +12VDC10% 0A 20A 20A 100mVp-p 1% 1% 80% 17VDC Max. Option None Yes Yes None
AD1240-24C +24VDC10% 0A 10A 10A 150mVp-p 1% 1% 81% 30VDC Max. Option None Yes Yes None
AD1240-48C +48VDC10% 0A 5A 5A 250mVp-p 1% 1% 83% 56VDC Max. Option None Yes Yes None

AD2240C Series Dual output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Reg. Reg. Function

+12VDC10% 0A 18A 18A 100mVp-p 1% 1% 16VDC Max.


AD22401C 77% None 200pcs None None None
+5VDC ------ 0A 3A 3A 60mVp-p 1% 1% -------
+24VDC10% 0A 9A 9A 150mVp-p 1% 1% 30VDC Max.
AD22402C 80% None 200pcs None Yes None
+5VDC ------ 0A 3A 3A 60mVp-p 1% 1% -------
+48VDC10% 0A 4.5A 4.5A 250mVp-p 1% 1% 56VDC Max.
AD22403C 82% None 200pcs None None None
+5VDC ------ 0A 3A 3A 60mVp-p 1% 1% -------

NOTE: 1. Each output is designed to supply up to Max. current, but total loading must be limited within rated output wattage.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 230VAC input.
4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic
capacitor parallel on the test point, at rated load and 230VAC input.
5. Efficiency is measured at rated load and 230VAC input.

P.7
DIN Rail Mounting Power Supply
111

100

240W

INPUT L DC OK

Input voltage ..............100~240VAC/120~370VDC N V Adj.

Input frequency........................................47~63Hz
Inrush current ....................................22A/115VAC Rdy

(Cold start) 44A/230VAC NC 110


Active PFC ...............................................PF>0.94 _
_
+
OUTPUT +
Hold-up time (Full load@230VAC) ......20mS Min.
Over voltage protection ....................Autorecovery
Overload protection .........................Power limited 11 110
Short circuit protection .....................Autorecovery

AD1360C Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant MOQ
Model Eff. O.V.P. CB UL TUV
Adjustment Min. Rated Max. Noise Reg. Reg. Function

AD1360-12C +12VDC10% 0A 30A 30A 100mVp-p 1% 1% 80% 17VDC Max. Option None Yes Yes None
AD1360-24C +24VDC10% 0A 15A 15A 150mVp-p 1% 1% 81% 30VDC Max. Option None Yes Yes None
AD1360-48C +48VDC10% 0A 7.5A 7.5A 250mVp-p 1% 1% 83% 56VDC Max. Option None Yes Yes None

AD2360C Series Dual output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Max. Noise Reg. Reg. Function

+12VDC10% 0A 28A 28A 100mVp-p 1% 1% 16VDC Max.


AD23601C 77% None 200pcs None None None
+5VDC ------ 0A 3A 3A 60mVp-p 1% 1% -------
+24VDC10% 0A 14A 14A 150mVp-p 1% 1% 30VDC Max.
AD23602C 80% None 200pcs None Yes None
+5VDC ------ 0A 3A 3A 60mVp-p 1% 1% -------
+48VDC10% 0A 7A 7A 250mVp-p 1% 1% 56VDC Max.
AD23603C 82% None 200pcs None None None
+5VDC ------ 0A 3A 3A 60mVp-p 1% 1% -------

NOTE: 1. Each output is designed to supply up to Max. current, but total loading must be limited within rated output wattage.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 230VAC input.
4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic
capacitor parallel on the test point, at rated load and 230VAC input.
5. Efficiency is measured at rated load and 230VAC input.

P.8
DIN Rail Mounting Power Supply
111

100

500W

L DC OK

INPUT N V Adj.

Input voltage ....................115/230VAC selectable +


Input frequency.......................................47~63Hz +
Inrush current ...................................22A/115VAC + 110
_
(Cold start) 44A/230VAC _
_
OUTPUT 220
NC

Hold-up time (Full load@230VAC) .....20mS Min.


Over voltage protection ...................Autorecovery
Overload protection ........................Power limited 11 110
Short circuit protection ....................Autorecovery
Dimensions:121(D)x110(H)x100(W)mm

AD1500S Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant MOQ
Model Eff. O.V.P. CB UL TUV
Adjustment Min. Rated Max. Noise Reg. Reg. Function

AD1500-24S +24VDC10% 0A 21A 21A 150mVp-p 1% 2% 86% 30VDC Max. Option None Yes Yes None
AD1500-48S +48VDC10% 0A 10.5A 10.5A 250mVp-p 1% 2% 86% 56VDC Max. Option None Yes Yes None

AD2500S Series Dual output


O/P voltage Ripple Line Load Redundant
Model Eff. O.V.P. MOQ CB UL TUV
Adjustment Noise Reg. Reg. Function

+24VDC10% 0A 20A 20A 150mVp-p 1% 2% 30VDC Max.


AD25002S 84% None 200pcs None None None
+5VDC ------ 0A 3A 3A 60mVp-p 1% 2% -------
+48VDC10% 0A 14A 14A 250mVp-p 1% 1% 56VDC Max.
AD25003S 84% None 200pcs None None None
+5VDC ------ 0A 3A 3A 60mVp-p 1% 2% -------

NOTE: 1. Each output is designed to supply up to Max. current, but total loading must be limited within rated output wattage.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 230VAC input.
4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic
capacitor parallel on the test point, at rated load and 230VAC input.
5. Efficiency is measured at rated load and 230VAC input.

P.9
DC Motor Power Supply

111

56

100W

DC OK

V.Adj.

+
INPUT _
_ 110
Input voltage ..............100~240VAC/120~370VDC
Input frequency........................................47~63Hz +
Inrush current ....................................22A/115VAC
(Cold start) 44A/230VAC N
L
OUTPUT
Hold-up time (Full load@230VAC) ......20mS Min.
11 110
Over voltage protection ....................Autorecovery
Overload protection .........................Power limited
Short circuit protection .....................Autorecovery
Dimensions:121(D)x110(H)x56(W)mm

AD1100MF Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Adjustment Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Min. Rated Peak Noise Function

AD1100M-24F +24VDC10% 0A 4A 8A 150mVp-p 1% 2% 80% 30VDC Max. Yes 300pcs None None None
AD1100M-48F +48VDC10% 0A 2A 4A 250mVp-p 1% 2% 81% 56VDC Max. Yes 300pcs None None None
AD1100M-72F +72VDC10% 0A 1.4A 2.8A 500mVp-p 1% 2% 81% 95VDC Max. Yes 300pcs None None None

AD2100MF Series Dual output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Peak Noise Function

+24VDC10% 0A 3.5A 7A 150mVp-p 1% 2% 30VDC Max.


AD2100M2F 79% None 300pcs None None None
+5VDC10% 0A 3A 3A 60mVp-p 1% 2% ------
+48VDC10% 0A 1.7A 3.5A 250mVp-p 1% 2% 56VDC Max.
AD2100M3F 80% None 300pcs None None None
+5VDC10% 0A 3A 3A 60mVp-p 1% 2% ------

NOTE: 1. Each output is designed to supply up to peak current within 3 minutes but total loading must be limited within
rated output wattage.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 230VAC input.
4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic
capacitor parallel on the test point, at rated load and 230VAC input.
5. Efficiency is measured at rated load and 230VAC input.

P.10
DC Motor Power Supply

111

75

150W

DC OK

V.Adj.

+
INPUT _
_ 110
Input voltage ..............100~240VAC/120~370VDC
Input frequency........................................47~63Hz +
Inrush current ....................................22A/115VAC
N
(Cold start) 44A/230VAC
L

OUTPUT
Hold-up time (Full load@230VAC) ......20mS Min.
Over voltage protection ....................Autorecovery
11 110
Overload protection .........................Power limited
Short circuit protection .....................Autorecovery Dimensions:121(D)x110(H)x75(W)mm

AD1150MF Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Adjustment Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Min. Rated Peak. Noise Function

AD1150M-24F +24VDC10% 0A 6.3A 10A 150mVp-p 1% 2% 80% 30VDC Max. Yes 300pcs None None None
AD1150M-48F +48VDC10% 0A 3.2A 5A 250mVp-p 1% 2% 81% 56VDC Max. Yes 300pcs None None None
AD1150M-72F +72VDC10% 0A 2A 3.5A 500mVp-p 1% 2% 81% 95VDC Max. Yes 300pcs None None None

AD2150MF Series Dual output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Peak. Noise Function

+24VDC10% 0A 5.5A 9A 150mVp-p 1% 2% 30VDC Max.


AD2150M2F 79% None 300pcs None None None
+5VDC10% 0A 3A 3A 60mVp-p 1% 2% ------
+48VDC10% 0A 3A 5A 250mVp-p 1% 2% 56VDC Max.
AD2150M3F 80% None 300pcs None None None
+5VDC10% 0A 3A 3A 60mVp-p 1% 2% ------

NOTE: 1. Each output is designed to supply up to peak current within 3 minutes but total loading must be limited within
rated output wattage.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 230VAC input.
4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic
capacitor parallel on the test point, at rated load and 230VAC input.
5. Efficiency is measured at rated load and 230VAC input.

P.11
DC Motor Power Supply

111

75

240W

DC OK

V.Adj.

INPUT +
_
Input voltage ....................115/230VAC selectable _ 110
Input frequency.......................................47~63Hz +
Inrush current ...................................22A/115VAC
(Cold start) 44A/230VAC N
230
L
OUTPUT
Hold-up time (Full load@230VAC) .....20mS Min.
Over voltage protection ...................Autorecovery 11 110
Overload protection ........................Power limited
Short circuit protection ....................Autorecovery
Dimensions:121(D)x110(H)x75(W)mm

AD1240MS Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Adjustment Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Min. Rated Peak Noise Function

AD1240M-24S +24VDC10% 0A 10A 15A 150mVp-p 1% 2% 80% 30VDC Max. Yes 300pcs None None None
AD1240M-48S +48VDC10% 0A 5A 7.5A 250mVp-p 1% 2% 81% 56VDC Max. Yes 300pcs None None None
AD1240M-72S +72VDC10% 0A 3.5A 5.5A 500mVp-p 1% 2% 81% 95VDC Max. Yes 300pcs None None None

AD2240MS Series Dual output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Adjustment Min. Rated Peak Noise Function

+24VDC10% 0A 9A 14A 150mVp-p 1% 2% 30VDC Max.


AD2240M2S 79% None 300pcs None None None
+5VDC10% 0A 3A 3A 60mVp-p 1% 2% ------
+48VDC10% 0A 4.5A 7A 250mVp-p 1% 2% 56VDC Max.
AD2240M3S 80% None 300pcs None None None
+5VDC10% 0A 3A 3A 60mVp-p 1% 2% ------

NOTE: 1. Each output is designed to supply up to peak current within 3 minutes but total loading must be limited within
rated output wattage.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 230VAC input.
4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic
capacitor parallel on the test point, at rated load and 230VAC input.
5. Efficiency is measured at rated load and 230VAC input.

P.12
DC Motor Power Supply

111

100

500W

L DC OK
INPUT N V Adj.

Input voltage ....................115/230VAC selectable +


Input frequency.......................................47~63Hz +
Inrush current ...................................22A/115VAC +
110
_
(Cold start) 44A/230VAC _
_
OUTPUT NC
230

Hold-up time (Full load@230VAC) .....20mS Min.


Over voltage protection ...................Autorecovery
Overload protection ........................Power limited 11 110
Short circuit protection ....................Autorecovery
Dimensions:121(D)x110(H)x100(W)mm

AD1500MS Series Single output


O/P voltage Loading (A) Ripple Line Load Redundant
Model Adjustment Reg. Reg. Eff. O.V.P. MOQ CB UL TUV
Min. Rated Peak Noise Function

AD1500M-24S +24VDC10% 0A 21A 30A 150mVp-p 1% 2% 80% 30VDC Max. Yes 300pcs None None None
AD1500M-48S +48VDC10% 0A 10.5A 15A 250mVp-p 1% 2% 81% 56VDC Max. Yes 300pcs None None None
AD1500M-72S +72VDC10% 0A 7A 10.5A 500mVp-p 1% 2% 81% 95VDC Max. Yes 300pcs None None None

NOTE: 1. Each output is designed to supply up to peak current within 3 minutes but total loading must be limited within
rated output wattage.
2. Line regulation is measured from low line to high line at rated load.
3. Load regulation is measured from 20% to 100% of rated load at 230VAC input.
4. Ripple & Noise is measured by using a 0.1uF/630V metalized capacitor & a 47uF electrolytic
capacitor parallel on the test point, at rated load and 230VAC input.
5. Efficiency is measured at rated load and 230VAC input.

P.13
Lead-Acid Battery Charger

111

56

72W

Floating

Boosting

INPUT
Bat+
Input voltage ..............100~240VAC/120~370VDC Bat+
Input frequency........................................47~63Hz Bat - 110
Inrush current ....................................22A/115VAC Bat -
(Cold start) 44A/230VAC
N
OUTPUT L
Hold-up time (Full load@230VAC) .. ....20mS Min.
Over voltage protection ................ ....Autorecovery
Overload protection .................. .......Power limited
11
Short circuit protection ............... ......Autorecovery
Reverse polarity protection ...... ........Autorecovery
Dimensions:121(D)x110(H)x56(W)mm

AD1072CF Series 3-Stage Charging Control


Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

AD1072C-12F +14.7VDC +13.8VDC 6A Max. 1% 1% 80% 22VDC Max. 200pcs None None None
AD1072C-24F +29.4VDC +27.6VDC 3A Max. 1% 1% 82% 37VDC Max. 200pcs None None None

Charging curve

VDC A
Type 12V 24V
Code 1
2
a (A) 6.0 3.0 a
b (A) 0.6 0.6

1 (VDC) 14.7 29.4


b
2 (VDC) 13.8 27.6

Charg ing time

P.14
Lead-Acid Battery Charger
111

56

72W

Charging
Indication
V.Adj.

INPUT
Bat.+
Input voltage ..............100~240VAC/120~370VDC Bat.- 110
Input frequency........................................47~63Hz
Rdy
Inrush current ....................................22A/115VAC
(Cold start) 44A/230VAC
N
OUTPUT
L
Hold-up time (Full load@230VAC) .. ....20mS Min.
Over voltage protection .....................Autorecovery
Overload protection ..........................Power limited
11 110
Short circuit protection ......................Autorecovery
Reverse polarity protection ...............Autorecovery
Dry contact alarm signal ...........................1A relay
Dimensions:121(D)x110(H)x56(W)mm

AD1072CFR Series 3-Stage Charging Control


Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

AD1072C-12FR +14.7VDC +13.8VDC 6A Max. 1% 1% 80% 22VDC Max. 200pcs None None None
AD1072C-24FR +29.4VDC +27.6VDC 3A Max. 1% 1% 82% 37VDC Max. 200pcs None None None

Charging curve

VDC A
Type 12V 24V
Code 1
2
a (A) 6.0 3.0 a
b (A) 0.6 0.6

1 (VDC) 14.7 29.4


b
2 (VDC) 13.8 27.6

Charg ing time

P.15
Lead-Acid Battery Charger

111

75

120W

INPUT Floating

Boosting
Input voltage ..............100~240VAC/120~370VDC
Input frequency........................................47~63Hz Bat+
Inrush current ....................................22A/115VAC Bat+
(Cold start) 44A/230VAC Bat - 110

Bat -
OUTPUT
N
Hold-up time (Full load@230VAC) .. ....20mS Min.
Over voltage protection ................ ....Autorecovery L
Overload protection .................. .......Power limited
Short circuit protection ............... ......Autorecovery
Reverse polarity protection ...... ........Autorecovery 11 110

Dimensions:121(L)x110(W)x75(H)mm

AD1120CF Series 3-Stage Charging Control


Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

AD1120C-12F +14.7VDC +13.8VDC 10A Max. 1% 1% 81% 22VDC Max. 200pcs None None None

AD1120C-24F +29.4VDC +27.6VDC 5A Max. 1% 1% 82% 37VDC Max. 200pcs None None None
AD1120C-48F +58.8VDC +55.2VDC 2.5A Max. 1% 1% 84% 51VDC Max. 200pcs None None None

Charging curve
VDC A

Type 1
Code 12V 24V 48V
2 a
a (A) 10 5 2.5
b (B) 0.6 0.6 0.6
2 (VDC) 14.7 29.4 58.8
b
3 (VDC) 13.8 27.6 55.2

Charg ing time

P.16
Lead-Acid Battery Charger

111

75

No.:AD120
Dimensions:121x110x75mm

120W

INPUT Charging
Indication

Input voltage ..............100~240VAC/120~370VDC V. adj.

Input frequency........................................47~63Hz
Bat+
Inrush current ....................................22A/115VAC
Bat -
(Cold start) 44A/230VAC 110
Rdy
OUTPUT
Hold-up time (Full load@230VAC) .......20mS Min. N
Over voltage protection .....................Autorecovery L
Overload protection ..........................Power limited
Short circuit protection ......................Autorecovery
Reverse polarity protection ...............Autorecovery 11 110
Dray contact alarm signal .........................1A relay

Dimensions:121(L)x110(W)x75(H)mm

AD1120CFR Series 3-Stage Charging Control


Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

AD1120C-12FR +14.7VDC +13.8VDC 10A Max. 1% 1% 81% 22VDC Max. 200pcs None None None

AD1120C-24FR +29.4VDC +27.6VDC 5A Max . 1% 1% 82% 37VDC Max. 200pcs None None None
AD1120C-48FR +58.8VDC +55.2VDC 2.5A Max. 1% 1% 84% 51VDC Max. 200pcs None None None

Charging curve
VDC A

Type 1
Code 12V 24V 48V
2 a
a (A) 10 5 2.5
b (B) 0.6 0.6 0.6
2 (VDC) 14.7 29.4 58.8
b
3 (VDC) 13.8 27.6 55.2

Charg ing time

P.17
Enclosed Power Supply

73

147

INPUT
Input voltage ..............100~240VAC/120~370VDC
Input frequency........................................47~63Hz
Inrush current ....................................22A/115VAC
(Cold start) 44A/230VAC

OUTPUT
Hold-up time (Full load@230VAC) .. ....20mS Min. 45
Over voltage protection .............. ......Autorecovery
Overload protection ................ .........Power limited
Short circuit protection ............ .........Autorecovery
Reverse polarity protection ...... ........Autorecovery

Dimensions:147(L)x73(W)x45(H)mm

AE1060CF Series 3-Stage Charging Control


Charging voltage Charging current
Model Boost Float (A) Line Reg. Load Reg. Efficiency O.V.P. MOQ CB UL TUV

AE1060C-12F +14.7VDC +13.8VDC 5A Max. 1% 1% 80% 17VDC Max. 200pcs None None None

AE1060C-24F +29.4VDC +27.6VDC 2.5A Max. 1% 1% 83% 35VDC Max. 200pcs None None None

Charging curve

VDC A
Type 12V 24V
Code 1
2
a (A) 5 2.5 a
b (A) 0.6 0.6

1 (VDC) 14.7 29.4


b
2 (VDC) 13.8 27.6

Input : IEC320 C14 socket Charg ing time


DC output : 1.2m, 18AWG x2 + alligator clip

P.18
Lead-Acid Battery Charger

175

INPUT
Input voltage ..............100~240VAC/120~370VDC
Input frequency........................................47~63Hz
Inrush current ....................................22A/115VAC
(Cold start) 44A/230VAC

OUTPUT 88
50.5

5
Hold-up time (Full load@230VAC) .. ....20mS Min.
Over voltage protection ................ ....Autorecovery
Overload protection .................. .......Power limited
Short circuit protection ............... ......Autorecovery
Reverse polarity protection ...... ........Autorecovery
Over temperature protection ............Power limited

Dimensions:175(L)x88(W)x55.5(H)mm

AE1090CF Series Built-in MCU


Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

AE1090C-24F +29.4VDC +27.6VDC 3.5A Max. 1% 1% 84% 37VDC Max. 200pcs None None None
AE1090C-36F +44.1VDC +41.4VDC 2.5A Max. 1% 1% 84% 51VDC Max. 200pcs None None None
AE1090C-48F +58.8VDC +55.2VDC 1.8A Max. 1% 1% 85% 67VDC Max. 200pcs None None None

Charging curve
VDC Rescue Floating
Charge
Constant
Current
Constant Voltage
Charge
A
1
Type 2 a
Code 24V 36V 48V

a (A) 3.6 2.5 1.8


1 (VDC) 29.4 44.1 58.8 3
2 (VDC) 27.6 41.4 55.2
3 (VDC) 16 24 32
30Mins.
Input connection: IEC320 C14 socket Cha rging time
DC output: 1.2m, 16AWG x2 + alligator clip

P.19
Lead-acid Battery Charger

INPUT
Input voltage ..............100~240VAC/120~370VDC
Input frequency........................................47~63Hz
Inrush current ....................................22A/115VAC
(Cold start) 44A/230VAC

OUTPUT
Hold-up time (Full load@230VAC) .. ....20mS Min.
Over voltage protection ................ ....Autorecovery
Overload protection .................. .......Power limited
Short circuit protection ............... ......Autorecovery
Reverse polarity protection ...... ........Autorecovery
Over temperature protection ............Power limited
Dimensions:188(L)x97(W)x52(H)mm

AE1150CFA Series 3-Stage Charging Control


Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

AE1150C-12FA +14.7VDC +13.8VDC 12.5A Max. 1% 1% 82% 17VDC Max. 200pcs None None None
AE1150C-24FA +29.4VDC +27.6VDC 6.5A Max. 1% 1% 83% 35VDC Max. 200pcs None None None
AE1150C-48FA +58.8VDC +55.2VDC 4A Max. 1% 1% 84% 52VDC Max. 200pcs None None None

Charging curve

VDC A
Type 48V
Code 12V 24V
1
a (A) 12.5 6.5 4 2 a
b (A) 0.6 0.6 0.6

1 (VDC) 14.7 29.4 58.8


b
2 (VDC) 13.8 27.6 55.2

Input connection: IEC320 C14 socket


DC output: 1.2m, 16AWG x2 + alligator clip Charg ing time

P.20
Lead-acid Battery Charger

175

INPUT
Input voltage ..............100~240VAC/120~370VDC
Input frequency........................................47~63Hz
Inrush current ....................................22A/115VAC
(Cold start) 44A/230VAC

OUTPUT 88
50.5 5
Hold-up time (Full load@230VAC) .. ....20mS Min.
Over voltage protection ................ ....Autorecovery
Overload protection .................. .......Power limited
Short circuit protection ............... ......Autorecovery
Reverse polarity protection ...... ........Autorecovery
Over temperature protection ............Power limited

Dimensions:175(L)x88(W)x55.5(H)mm
AE1150CFC Series Built-in MCU
Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

AE1150C-12FC +14.7VDC +13.6VDC 12.5A Max. 1% 2% 83% 17VDC Max. 200pcs None None None
AE1150C-24FC +29.4VDC +27.2VDC 6.5A Max. 1% 2% 84% 35VDC Max. 200pcs None None None
AE1150C-36FC +44.1VDC +40.8VDC 4.1A Max. 1% 2% 84% 50VDC Max. 200pcs None None None
AE1150C-48FC +58.8VDC +54.4VDC 3.2A Max. 1% 2% 84% 67VDC Max. 200pcs None None None

Charging curve
VDC Rescue Floatin g
Charge
Constant
Current
Constant Volta ge
Charge
A
Type
Code 12V 24V 36V 48V 1
2 a
a (A) 12.5 6.5 4.1 3.2
1 (VDC) 14.7 29.4 44.1 58.8
2 (VDC) 13.6 3
27.2 40.8 54.4
3 (VDC) 8 16 24 32

2hrs t 2.5t (5hrs Max.)


Input connection: IEC320 C14 socket Charging time
DC output: 1.2m, 16AWG x2 + alligator clip

P.21
Lead-acid Battery Charger
1.5

20

99

INPUT
4
Input voltage ..............100~240VAC/120~370VDC
Input frequency........................................47~63Hz
Inrush current ....................................22A/115VAC 20
(Cold start) 44A/230VAC
1.5
OUTPUT
Hold-up time (Full load@230VAC) .. ....20mS Min.
Over voltage protection ................ ....Autorecovery
Overload protection .................. .......Power limited 59
Short circuit protection ............... ......Autorecovery
Reverse polarity protection ...... ........Autorecovery
Over temperature protection ............Power limited
153
Dimensions:150(L)x153(W)x59(H)mm

EPS 150W Series Built-in MCU


Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

EPS 1210 +14.7VDC +13.8VDC 10.0A Max. 1% 2% 83% 17VDC Max. 200pcs None None None
EPS 2405 +29.4VDC +27.6VDC 5.0A Max. 1% 2% 84% 35VDC Max. 200pcs None None None

Charging curve

VDC Rescue Floating


Charge
Constant
Current
Constant Voltage
Charge
A
Type 12V 24V 1
Code 2 a
a (A) 10.0 5.0

1 (VDC) 14.7 29.4

2 (VDC) 3
13.8 27.6

3 (VDC) 8.0 16.0

30Mins.
Cha rging time
Input connection: IEC320 C14 socket
DC output: 1.2m, 16AWG x2 + alligator clip

P.22
Lead-acid Battery Charger
1.5

25
4

139

INPUT
Input voltage .....................115/230VAC selectable
Input frequency........................................47~63Hz
4
Inrush current ....................................22A/115VAC
(Cold start) 44A/230VAC 25

OUTPUT 1.5
Hold-up time (Full load@230VAC) .. ....20mS Min.
Over voltage protection ................ ....Autorecovery I
Overload protection .................. .......Power limited 115V

59 230V O
Short circuit protection ............... ......Autorecovery
Reverse polarity protection ...... ........Autorecovery
Over temperature protection ............Power limited
153

Dimensions:200(L)x153(W)x59(H)mm
EPS 240W Series Built-in MCU
Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

EPS 1220 +14.7VDC +13.8VDC 20A Max. 1% 2% 84% 17VDC Max. 200pcs None None None
EPS 2410 +29.4VDC +27.6VDC 10A Max. 1% 2% 86% 35VDC Max. 200pcs None None None

Charging curve
VDC Rescue Floating
Charge
Constant
Current
Constant Voltage
Charge
A
Type 12V 24V
1
Code 2 a
a (A) 20.0 10.0

1 (VDC) 14.7 29.4


3
2 (VDC) 13.8 27.6
3 (VDC) 8.0 16.0

30Mins.
Cha rging time
Input connection: IEC320 C14 socket
DC output: 1.2m, 14AWG x2 + alligator clip

P.23
Lead-acid Battery Charger
102

115V
60

O
I

60
INPUT
Input voltage .....................115/230VAC selectable
Input frequency........................................47~63Hz 230
Inrush current ....................................22A/115VAC
(Cold start) 44A/230VAC

OUTPUT
Hold-up time (Full load@230VAC) .. ....20mS Min.
Over voltage protection ................ ....Autorecovery
Overload protection .................. .......Power limited
Short circuit protection ............... ......Autorecovery
Reverse polarity protection ...... ........Autorecovery
Over temperature protection ............Power limited
Dimensions:200(L)x153(W)x59(H)mm
AE1360CS Series Built-in MCU
Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

AE1360C-24S +29.4VDC +27.6VDC 15A Max. 1% 1% 84% 35VDC Max. 200pcs None None None
AE1360C-48S +58.8VDC +55.2VDC 7.5A Max. 1% 1% 84% 70VDC Max. 200pcs None None None

AE1500CS Series Built-in MCU


Charging voltage Charging current Efficiency
Model Boost Float Line Reg. Load Reg. O.V.P. MOQ CB UL TUV
(A)

AE1500C-24S +29.4VDC +27.6VDC 20A Max. 1% 1% 84% 35VDC Max. 200pcs None None None
AE1500C-48S +58.8VDC +55.2VDC 10A Max. 1% 1% 84% 70VDC Max. 200pcs None None None

Charging curve
VDC Rescue Floating
Series AE1360CS AE1500CS Charge
Constant
Current
Constant Voltage
Charge
A
Type 24V 48V 24V 48V 1
Code 2 a
a (A) 15 7.5 20 10
1 (VDC) 14.7 29.4 14.7 29.4
3
2 (VDC) 13.8 27.6 13.8 27.6

3 (VDC) 16 32 16 32

Input : IEC320 C14 socket 30Mins.


Cha rging time
DC output : 1.2m, 14AWG x2 + alligator clip

P.24
Custom - Made Products

LED Application

Back-up Power Ssupply

LCD Application

Battery Charger