Académique Documents
Professionnel Documents
Culture Documents
1/4
Infosheet BUILD STAGE
Incremental angle
Is the orientation of the new consecutive printed layers. Default
value is 67.
Saving databases
Click on the icon and browse for a directory to save the material
database.
The inherent strain values depend on the machine type and the
manufacturing parameters. To achieve accurate results, it is
recommended to perform a calibration. The product library can
be used to save and retrieve reference values.
2/4
Infosheet BUILD STAGE
3/4
Infosheet BUILD STAGE
Measuring distortion Use the check marks to indicate if a sample (e.g. 45) should be
included or not in the calibration. By clicking on the unit tab,
Measure the maximum z-distortion or height after cutting each
you can indicate the input units desired for the experimental values
printed cantilever beam. To achieve optimal results, measure each (e.g. in).
sample at the center of the cantilever.
Acceptable deviation
Is correlated with the certainty of the calibration. A large value is
correlated with less CPU time at the expense of a more
uncertainty. A small value will lead to accurate results, but more
simulations will be required. The default value is 3%.
Calibrate ez
If this option is enabled, the inherent strain values in the z direction
will be considered in the calibration. By default it is not taken into
account, as the influence on the distortion and stress of the part is
low.
4/4