Académique Documents
Professionnel Documents
Culture Documents
Humidity Sensors
2 www.honeywell.com/sensing
Humidity Sensors
FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment.)
Relative Humidity
100%
90%
80%
70%
Relative Humidity
60%
50%
40%
30%
20%
10%
0%
-40 -20 0 20 40 60 80 100 120 140
Recommended storage zone
Temperature C
3.5
3
Output Voltage (Vdc)
2.5
Sensor Response
Sensor Response
Best Linear Fit
2
1.5
0.5
0 20 40 60 80 100
Relative Humidity (%RH)
FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 C, 70 C and 5 V.)
4.5
3.5
3
Output Voltage (Vdc)
2.5
0C
70 C
2
1.5
0.5
0
0 10 20 30 40 50 60 70 80 90 100
Relative Humidity (%)
4 www.honeywell.com/sensing
Humidity Sensors
FIGURE 5. HIH-4000 SERIES MOUNTING DIMENSIONS (For reference only. mm/[in])
HIH-4000-002 HIH-4000-001
HIH-4000-004 HIH-4000-003
HIH-4000-005
4,17 2,03
4,17 [0.080]
[0.164] [0.164]
8,59 8,59
[0.338] [0.338]
1,91
[0.075]
12,2 MIN.
12,70 MIN. [0.48]
[0.50]
OUT OUT
3X 0,38 3X 0,38
[0.015] [0.015]
1,27
[0.050] 2,54 0,72 2,54 0,72
2,54 [0.10 0.03]
[0.100] 5,08 REF. [0.10 0.03]
[0.20]
ORDER GUIDE
Catalog Listing Description
HIH-4000-001 Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP
HIH-4000-002 Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP
HIH-4000-003 Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP, calibration and data printout
HIH-4000-004 Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP, calibration and data printout
HIH-4000-005 Equivalent to HIH-4000-001
6 www.honeywell.com/sensing
Humidity Sensors
THIS PAGE INTENTIONALLY LEFT BLANK.