Vous êtes sur la page 1sur 4

extending the boundaries of technology

evolution of proven technology


Base Unit

FEATURES

• IEC 61850
• IEC 61131-3 logic
• Expandable I/O A Callistonx Base Unit provides
• 16 DI, 6 DO on base unit the foundation level standalone
• 1 Ethernet, 2 serial ports as standard solution for small point count RTU’s,
• Multi-protocol support
• Powerful 32bit RISC processor
with modular expansion facilities
• Embedded Linux OS satisfying the largest configurations
• Complete suite of diagnostic and of substation automation.
configuration tools
Base Unit Features

SD Flash:
Callistonx Base Unit provides • For data logging and storage
six expansion slots for
Terminations:
instrumentation class AC, DC • Screwless terminals
analogues, digital I/O and • Screw terminal block
• Barrier block type
comprehensive IED support
using a standalone library of
plug-in modules.
General:
• Cost effective compact design
• Solutions for switchgear manufacturers and system integrators
• Open architecture which is IEC 61850 ready supporting both
station and process bus
• 20,000 point database capacity.
• High reliability

Technology & Performance:


• State of the art technology utilising NS9750 (Arm 9)
processor working in tandem with Blackfin DSP
• In service upgradeable FLASH based boot system for
Base I/O:
upgrades on the fly • 16 digital inputs
• 6 command output

Monitoring & Watchdog : Miscellaneous:


• Comprehensive power failure detection and intelligent • Dummy control
mechanisms to safely store critical data without the use of • High stability voltage reference
onboard battery technology
• External PSU hold up facilities, are also available to increase Integrated Communications Ports:
the holdup period if necessary • 1 Ethernet port (10/100 BaseTX)
• A comprehensive watchdog subsystem covers internal voltage • Integral managed Ethernet switch for flexible station and
rails, Blackfin DSP, NS9750 processor, memory and other process bus implementation
important components • 2 Isolated serial ports

Temperature Sensor:
• Onboard temperature sensor monitors the ambient
temperature to dynamically compensate temperature
sensitive electronics
Networked configurations using
a comprehensive library of
Control Output Enable:
• The Callistonx supports a hard-wired control output standalone modules.
enable/disable facility
Integrated Web based browser
Time Synchronisation:
• An integrated GPS receiver (option) provides time to ensure and programmable logic facility
Ims time accuracy for SOE data
• Better than 5ms/hour when not synchronised (GPS/master/LAN)
for maximum applications facility.
• Time source prioritisation

2
Dimensions:
• Base Unit • Base Unit
(no PSU) (with PSU/cover)

286mm

286mm
1 USB Port (V 2.0):
• Data rates up to 480Mbits/sec
• Hotswapping of devices 255mm 63 m m
m 9m
• Future expansion 255mm 14

1 CANbus/I2C For General expansion:


• Mini DIN connector Power Supply Features
• 1Mbit/s CANbus
• 100kbit/s I2C bus
• Connection to Remsdaq’s Actuator Interface Board • Options to cover all standard substation voltages
and future expansion devices • High contrast LCD for monitoring and diagnostics
• 2 0-20mA analogue inputs
• 12 bit ADC
• Accuracy 0.2% @ 25°C

Real Time Software: • Integral intelligent charger (option)


• Embedded Linux • Onboard temperature sensor
• Viewnx, an embedded web server which provides access • Optimised charger characteristics to maximise battery lifetime
to configuration, commissioning tools and diagnostics. • Nominal input voltage: 48VDC (45-56V)
nx
• PC configuration using the Callisto Software Environment CaSE • Maximum charge current 2.4A
• Integral wetting supply (option)
Memory: • Back-up DC supply mode
• FLASH 16MB or 32MB (IEC 61850) • Mains fail detection
• SDRAM 40MB (8MB of which is dedicated to the DSP)
• SD FLASH slot

Integral Power Supply:


• Integrated non isolated power supply 24V (18-40V)
• Power consumption 32W (Max)

3
Ordering Information

Base Unit:
Product Product Type Opt 1 Opt2 Opt 3
Range Code Options
CX BU xxx xxx xxx x
S Screwless Terminals
T Screw Terminals
B Barrier-Block Terminals

S No GPS
GPS GPS

012 12V* DC (nominal) Digital Inputs (Max 18V, On 8V, Off 5V)*
024 24V* DC (nominal) Digital Inputs (Max 36V, On 16V, Off 12V)*
048 48V* DC (nominal) Digital Inputs (Max 72V, On 30V, Off 24V)*
110 110V* DC (nominal) Digital Inputs (Max 170V, On 75V, Off 50V)*
220 220V* DC (nominal) Digital Inputs (Max 300V, On 150V, Off 85V)*

S Standard
NAC No AC Analogs
850 IEC 61850 (includes AC Analogs)

BU Base Processing Node

*Guaranteed on/off voltages

Power Supply:
Product Product Type Opt 1 Opt2 Opt 3
Range Code Options
CX PS xxx xxx xxx x
S Screwless Terminals
T Screw Terminals
B Barrier-Block Terminals

110 110V AC Mains Fail Detection


BC
240 240V AC Mains Fail Detection
Other X Option Not Applicable

S Standard (None)
012 12V DC Isolated Wetting Output
BC
024 24V DC Isolated Wetting Output
048 48V DC Isolated Wetting Output
012 10-20V DC Isolated Supply (-20 to +70 degrees C)
024 18-36V DC Isolated Supply (-20 to +70 degrees C)
048 36-76V DC Isolated Supply (-20 to +70 degrees C)
I
110 66-160V DC Isolated Supply (-20 to +70 degrees C)
125 82-185V DC Isolated Supply (-20 to +70 degrees C))
220 100-375V DC Isolated Supply (-20 to +70 degrees C)
012 10-20V DC Isolated Supply (-40 to +70 degrees C)
024 18-36V DC Isolated Supply (-40 to +70 degrees C)
048 36-76V DC Isolated Supply (-40 to +70 degrees C)
ILT 66-160V DC Isolated Supply (-40 to +70 degrees C)
110
125 82-185V DC Isolated Supply (-40 to +70 degrees C))
220 100-375V DC Isolated Supply (-40 to +70 degrees C)
NI 024 20-40V DC Non-Isolated Supply

BC Battery Charger/Backup DC
I Isolated DC (Standard -25 to +70 degrees C)
ILT Isolated DC (Low Temp -40 to +70 degrees C)
NI Non-Isolated DC

PS Power Supply Unit

Remsdaq Limited, Parkway, Deeside Industrial Park, Deeside, Flintshire, CH5 2NL, United Kingdom.
tel: +44 (0) 1244 286495 fax: +44 (0) 1244 286496 web: www.remsdaq.com mail: sales@remsdaq.com Registered in England No. 3417251.

Remsdaq has a policy of continuous product development and improvement.


Whilst all information is correct at the time of going to press, we reserve the right to make changes without notice. All trademarks are duly acknowledged.

Vous aimerez peut-être aussi