Clean Room Air Handling Unit

Bueco Co., Ltd.


About us
Bueco Co., Ltd. is established by an excellent engineers' team who is in the HVAC
business for more than a decade. Different companies has different strength, Bueco's
aim is to combines the various advantage of the HVAC players in Shandong and other
provinces, China.

With the clear understanding capability of its client, Bueco focuses on the air cooled
water chiller and heat pump, water cooled water chiller and heat pump, air handling
unit, fan coil unit, rooftop packaged unit and other HVAC accessories required by
customers.

All Bueco products have different certificates, CE, AHRI, CCC, China National Test Report.
ISO9001:2008 and ISO 14001:2004 certified for the company.

Thanks for the trust and supports of our clients, Bueco has been delivered to Algeria,
Nigeria, Ethopia, Angola, South Africa, Indonesia, Cambodia, Philippines, Thailand,
Malaysia, South Korea, Japan, Pakistan, India, Sri Lanka, Mongolia etc.

With the conception, creation in techology and value, Bueco is growing up with its
clients, workers with quality products and quality life.
Certificate/License
Enterprise Qualification

The group is operated with the conception of Morality first, humanity first and Customer first and in
team work, the quality management system is customer oriented, supplies customers with products of high
technology, high quality and efficient service.

Its one of the companies who got the first lot of license of refrigeration equipment production in
China. We got the national 1st level qualification license on mechanical, electrical equipment installation,
2nd level qualification license on air purification engineering, hygiene license on Sheet Molding Compound
(SMC) product, and took the lead in the award of the license of pressure vessel design and manufacture.
The company is ISO9001, ISO14001, QHSAS18001 certified. Our air conditioning products have the
National Certificate of Refrigeration Equipment Production, 3C China Compulsory Certificate, CRAA China
Refrigeration Industry Performance Certificate, cooling tower product is certified as China Water Saving
Product and air handling unit is AHRI certified.
Contents

Pharmaceutical Air Handling Unit

1. Nomenclature 04
2. How to tell the water pipe connection direction, right or left? 04
3. About the AHU 05
4. Key components feature 05
5. Performance data 10
6. Dimension 14
7. AHU combination models 16
8. AHU commended projects 18
9. Combination option 20
10. Motor power input 22
11. Parts resistance 22
12. Quick selection guide 23
1. Nomenclature
ZK XX X X P

Pharmaceutical

Nos. of heating coil row

Nos. of cooling coil row

Air flow rate (x103m3/h)

Air handling unit

2. How to tell the difference of right or left connection?

Left

Right

Air intake

To look at the AHU from the air intake direction, it's right type if the chilled water pipe is at the right
side, and vice versa.

04
3. About the AHU
Its a complete system solution with unique advantage for the clean operation room
air handling unit, including machine and control integration, strong and week electricity
integration, convenient modular combination, positive pressure control, filter solution, bacteria
elimination and energy saving.

4. Key components feature


4.1 The frame & Panels
The frame , extruded aluminium alloy or plastic-steel, gives high
strength and stability, corrosion resistant coated, excellent insulation
values. Long life high quanlity gaskets are also used to ensure perfect
sealing. The special profile designs also give a great flexibility in
building different purpose modules. Double skin insulated panels
constructed with pre-painted steel was used in the Pharmaceutical
series AHU. High density rigid CFC was pressure injected between two
sheets to give high strength insulated double skin panels. Panels are
simply screwed or spring locked to frame. Standard panel thickness
are 50~90mm with insulation density of 45kg/m3, the interior
sheet can be colored steel or stainless steel according to client's

4.2 Fan & motor


This Pharmaceutical series AHUs are supplied with double inlet, double
width forward or backward curved centrifugal fans. All wheels are
statically and dynamically balanced to ISO1940 and AMCA 204-G2.5
Standards. All fans after assembly are trim-balanced to ISO1940 and
AMCA 204-G2.5 Standards. All bearings are either deep groove ball
type with an adaptor sleeve or spherical roller bearings type sealed
at both sides. Motors are totally enclosed fan cooled type with class F
insulation to IP55 protection, standard motor is Siemens, ABB or any
other appointed brand is optional.
The special design motor and fan base frame provide a very simple
and flexible installation and servicing method for fan and motor
adjustment. Base frames are completely isolated from the unit casing
to avoid vibration in cabinet.

05
4.3 Cooling & heating coil
Standard coils are constructed from copper tubes mechanically
bonded to aluminium fins, with threaded copper headers, all
contained in a galvanised steel frame.
Coil options are:
--Anti-corrosion coated coil. Copper & aluminum coil
--Steam distributor heating coils.
--Evaporator coils.
--Copper fins.
--Tinned copper fins adjustment. Base frames are completely isolated
from the unit casing to avoid vibration in cabinet.

All coils are computer selected to achieve the optimum psychrometric Copper & Copper coil
efficiency with low air and water pressure drops.
All coils are leak tested at 28bar with a maximum design pressure of 25
bar.
Condensate pans are a "dry pan" design, manufactured from stainless
steel.
Aluminium droplet eliminators are fitted after cooling coils when the air
velocity exceeds 2.5m/s. Anti freezing device
Antifreezing device can be added to protect the unit when necessary.
The steam heating coil has tube in tube design, liquid is separate from
vapor, no harm to coil due to water hammer effect, with builtin steam
distributor, the steam is distributed equally and efficiency is higher.
Standard steam heating coil is made of copper tube with anti corrosion
hydrophic aluminum fin.
Steam heating coil

4.4 Humidifiers
4.4.1 Steam humidifier
At the heart of the humidifier is an all-in-one steam connection unit
featuring a new rotary disk valve, which is linked to the tried-and-
tested steam distribution system and its patented steam nozzles. The
humidifier has one or more stainless steel distribution pipes.

4.4.2 Electrode humidifier


Consists of electrodes, steam cylinder, stainless steel distribution pipe
and electronic controls for water regulation and automatic flushing

06
4.4.3 Evaporative humidifier
A viscose-coated evaporating pack is moistened with water, used tap
water or circulated by an internally mounted pump from a stainless
steel tank.

4.4.4 Air washer


A externally mounted pump, draws water from a stainless steel tank, which has
a liquid level regulator, overflow, drain and flushing device. Spray distribution is
via a stainless steel pipes and nozzles. Sprays may be single or double row. The
inner panels in air washer is constructed from stainless steel sheets.
An air tight access hatch, with porthole, an internal light, a air equalizer plate or
a droplet eliminator are incorporated.

4.4. 5 Other humidifier


Electric steam humidifier
High-pressure atomizing humidifier
Air-water humidifier

4.5 Dehumidifcation and reheating device


Its has dehumidification and reheating function in one unit, lower dew
point control is realized with the support of chilled water coil and intelligent
control system.
Adopts Hitachi hermetic scroll compressor, all refrigeration components are
international famous brand.
Evaporator and condenser is made of copper tube with anticorrosion
hydrophilic aluminum fin.
Its completely assembled with its own control panel, no additional piping
required.
Its suitable for air conditioning system with low dew point range from
10~12, or the chilled water supply is not stable in summer and the indoor
humidity requirement is strict.

4.6 Heat recovery


The following forms of heat recovery equipment can be supplied:

4.6. 1 Plate heat exchanger


Manufactured from aluminium or hygroscopic paper plates and
turbulation channels to permit heat transfer from warm to colder air
systems without mixing the two air streams.

07
4.6. 2 Thermal wheel recovery
Available with a hygroscopic or non-hygroscopic rotor for recovering
and transferring heat energy from the exhaust to the supply air
streams.

4.6. 3 Heat pipe recovery


Two coils, charged with refrigerant, exchange heat by the evaporation
of warm air stream and re-condensation in the cold air stream.

4.6. 4 Coil heat recovery


Two coils, charged with water, circulated between the two coils by a
pump, exchange heat from warm to colder air systems.

4.7 Filters
The following forms of filter can be supplied:
4.7.1 Prefilters
Synthetic or glass-fibre media panel filters, class G2 to G4 arranged in

H
galvanised steel frames or sliding rails.
4.7.2 Main filters
Synthetic or glass-fibre media bag filters, class F5 to F9 arranged in
galvanised steel and luminium alloy frames with gaskets to avoid air
bypass.

4.7.3 Final filters


High efficiency compact cell filters, class H10 to H13 ,fixed with
brackets, nuts and bolts or clamps to a heavy galvanised steel
gasketted structure.

4.7.4 Filter option


Carbon & glass-fibre combined bag filter Camcard, chemical filter
cylinders ambient filter.

08
4.8 Ultraviolet lamp
Ultraviolet lamp only effective on the bacteria on object surface, it
can be used to eliminate the bacteria on the surface of filter, coil and
drain pan. C wave band 265nm ultraviolet lamp with quartz glass
lamp tube of long lifetime. There is one protection switch on the
access door of ultraviolet lamp, the lamp will be switched off when
the door is open for safety.

4.9 Dampers
Damper shall have high strength extruded aluminium blade, ABS
drive-gear, and shall be mounted internally / externally. The blades
shall be fitted with "O"-type sealing gasket.
Shafts and control rods shall be of steel or copper and shall be
purpose designed to suit the actuators. The damper shall be
controlled by means of manual or motorized.
Final dimension to be specified by customer.

4.10 Control system


The control system offers suitable controller as per the operation
requirement with friendly operation interface, famous control
components. AHU
4.10.1 Positive pressure Control
A. Centralized fresh air system, with air flow rate fixing device Control panel

B. Distributed fresh air system, with inverter measurement, the


air pressure is constant and air flow rate is fixed.
C. Exhaust air control, interlock with the door of surgery room.
4.10.2 Energy saving operation
A. Adopts secondary return air system, saves energy. Indoor control

B. Adopts VFD motor to control the air flow rate, saves energy.
C. Set the operation condition with the VFD system
Control system customization is available. User's PC

All panels can be easily removed on site by unscrewing or


unlocking outside of the unit. Access door shall be provided,
where necessary to allow inspection and service.
Inspection window and water proof lamp are recommended for
fan section and any other sections as required

09
5. Performance Data
5.1 Cooling coil specification return air condition
Air volume 4 Rows 6 Rows 8 Rows
ZK Flow- Flow- Flow- DP
TH SH DP TH SH DP TH SH
m3/h m3/s rate rate rate kPa
kW kW kPa kW kW kPa kW kW
l/s l/s l/s
02 2000 0.56 12.2 8.2 0.58 7.8 15.6 10.1 0.74 10.6 17.0 10.9 0.81 11.8
03 3000 0.83 18.3 12.3 0.87 7.8 23.4 15.2 1.12 10.6 25.5 16.3 1.22 11.8
04 4000 1.11 24.4 16.3 1.16 12.9 31.2 20.3 1.49 17.4 34.0 21.8 1.62 19.4
05 5000 1.39 30.5 20.4 1.46 20.0 39.0 25.4 1.86 27.0 42.5 27.2 2.03 30.0
06 6000 1.67 36.6 24.5 1.75 18.3 46.8 30.4 2.23 24.8 51.0 32.6 2.43 27.6
07 7000 1.94 42.7 28.6 2.04 19.5 54.6 35.5 2.61 26.4 59.5 38.1 2.84 29.3
08 8000 2.22 48.8 32.7 2.33 20.4 62.4 40.6 2.98 27.6 68.0 43.5 3.25 30.7
09 9000 2.50 54.9 36.8 2.62 21.2 70.2 45.6 3.35 28.7 76.5 49.0 3.65 31.9
10 10000 2.78 61.0 40.9 2.91 20.0 78.0 50.7 3.72 27.0 85.0 54.4 4.06 12.8
12 12000 3.33 73.2 49.0 3.49 21.2 93.6 60.8 4.47 28.7 102.0 65.3 4.87 13.6
14 14000 3.89 85.4 57.2 4.08 27.8 109.2 71.0 5.21 16.0 119.0 76.2 5.68 17.8
16 16000 4.44 97.6 65.4 4.66 30.2 124.8 81.1 5.96 17.4 136.0 87.0 6.49 19.4
18 18000 5.00 109.8 73.6 5.24 14.9 140.4 91.3 6.70 20.1 153.0 97.9 7.30 22.4
20 20000 5.56 122.0 81.7 5.82 16.9 156.0 101.4 7.45 22.9 170.0 108.8 8.11 25.5
25 25000 6.94 152.5 102.2 7.28 16.9 195.0 126.8 9.31 22.9 212.5 136.0 10.14 25.5
30 30000 8.33 183.0 122.6 8.73 16.9 234.0 152.1 11.17 22.9 255.0 163.2 12.17 25.5
35 35000 9.72 213.5 143.0 10.19 18.6 273.0 177.5 13.03 25.1 297.5 190.4 14.20 27.9
40 40000 11.11 244.0 163.5 11.65 23.0 312.0 202.8 14.89 31.1 340.0 217.6 16.23 14.7
45 45000 12.50 274.5 183.9 13.10 23.1 351.0 228.2 16.75 19.0 382.5 244.8 18.26 14.8
50 50000 13.89 305.0 204.4 14.56 25.2 390.0 253.5 18.61 20.7 425.0 272.0 20.29 16.1
60 60000 16.67 366.0 245.2 17.47 31.5 468.0 304.2 22.34 25.9 510.0 326.4 24.34 20.2
70 70000 19.44 427.0 286.1 20.38 14.4 546.0 354.9 26.06 27.7 595.0 380.8 28.40 21.6
80 80000 22.22 488.0 327.0 23.29 16.9 624.0 405.6 29.78 32.7 680.0 435.2 32.46 25.5
90 90000 25.00 549.0 367.8 26.20 19.6 702.0 456.3 33.51 37.8 765.0 489.6 36.51 29.5
100 100000 27.78 610.0 408.7 29.12 20.7 780.0 507.0 37.23 39.9 850.0 544.0 40.57 31.1
120 120000 33.33 732.0 490.4 34.94 25.9 936.0 608.4 44.68 35.0 1020.0 652.8 48.68 38.9
140 140000 38.89 854.0 572.2 40.76 27.3 1092.0 709.8 52.12 36.9 1190.0 761.6 56.80 41.1
160 160000 44.44 976.0 653.9 46.58 32.2 1248.0 811.2 59.57 43.5 1360.0 870.4 64.91 20.6
180 180000 50.00 1098.0 735.7 52.41 28.6 1404.0 912.6 67.01 38.7 1530.0 979.2 73.03 18.4
200 200000 55.56 1220.0 817.4 58.23 32.6 1560.0 1014.0 74.46 44.4 1700.0 1088.0 81.14 20.9

Notes:
1. TH Total heat capacity;
2. SH Sensible heat capacity;
3. DP Water pressure drop;
4. Entering air dry bulb temp. 27, entering air wet bulb tem. 19.5;
5. Entering/leaving water temperature 7/12;
6. Coil face velocity 2.5m/s.

10
5.2 Cooling coil specification fresh air condition
Air volume 4 Rows 6 Rows 8 Rows
ZK Flow- Flow- Flow- DP
TH SH DP TH SH DP TH SH
m3/h m3/s rate rate rate kPa
kW kW kPa kW kW kPa kW kW
l/s l/s l/s
02 2000 0.56 25.0 10.3 1.19 18.9 32.0 13.1 1.53 25.6 34.9 14.3 1.66 28.4
03 3000 0.83 37.5 15.4 1.79 18.9 48.0 19.7 2.29 25.6 52.3 21.4 2.50 28.4
04 4000 1.11 50.0 20.5 2.39 31.1 64.0 26.2 3.05 18.0 69.7 28.6 3.33 20.0
05 5000 1.39 62.5 25.6 2.98 20.6 80.0 32.8 3.82 27.9 87.1 35.7 4.16 31.0
06 6000 1.67 75.0 30.8 3.58 18.9 95.9 39.3 4.58 25.6 104.6 42.9 4.99 28.4
07 7000 1.94 87.5 35.9 4.18 20.1 111.9 45.9 5.34 27.2 122.0 50.0 5.82 30.2
08 8000 2.22 100.0 41.0 4.77 21.0 127.9 52.4 6.11 28.5 139.4 57.2 6.65 31.7
09 9000 2.50 112.5 46.1 5.37 21.9 143.9 59.0 6.87 29.6 156.8 64.3 7.49 14.0
10 10000 2.78 125.1 51.3 5.97 20.6 159.9 65.6 7.63 27.9 174.3 71.4 8.32 13.2
12 12000 3.33 150.1 61.5 7.16 21.9 191.9 78.7 9.16 29.6 209.1 85.7 9.98 14.0
14 14000 3.89 175.1 71.8 8.36 28.6 223.9 91.8 10.68 23.5 244.0 100.0 11.64 18.3
16 16000 4.44 200.1 82.0 9.55 31.1 255.8 104.9 12.21 25.6 278.8 114.3 13.31 20.0
18 18000 5.00 225.1 92.3 10.74 15.3 287.8 118.0 13.76 29.6 313.7 128.6 14.97 23.1
20 20000 5.56 250.1 102.5 11.94 17.5 319.8 131.1 15.26 33.7 348.5 142.9 16.63 26.3
25 25000 6.94 312.6 128.2 14.92 17.5 399.8 163.9 19.08 33.7 435.6 178.6 20.79 26.3
30 30000 8.33 375.2 153.8 17.91 17.5 479.7 196.7 22.90 33.7 522.8 214.3 24.95 26.3
35 35000 9.72 437.7 179.4 20.89 19.1 559.8 229.5 26.71 36.9 609.9 250.0 29.11 28.8
40 40000 11.11 500.2 205.1 23.87 23.7 639.6 262.2 30.53 45.6 697.0 285.8 33.27 35.6
45 45000 12.50 562.7 230.7 26.86 23.8 719.6 295.0 34.34 45.9 784.1 321.5 37.43 35.8
50 50000 13.89 625.3 256.4 29.84 25.9 799.5 327.8 38.16 21.3 871.3 357.2 41.58 39.0
60 60000 16.67 750.3 307.6 35.81 32.5 959.4 393.4 45.79 26.7 1045.5 428.7 49.90 20.8
70 70000 19.44 875.4 358.9 41.78 34.8 1119.3 458.9 53.42 28.6 1219.8 500.1 58.22 22.3
80 80000 22.22 1000.4 410.2 47.75 41.0 1279.2 524.5 61.06 33.7 1394.0 571.5 66.54 26.3
90 90000 25.00 1125.5 461.4 53.72 47.4 1439.1 590.0 68.69 38.9 1568.3 643.0 74.85 30.4
100 100000 27.78 1250.5 512.7 59.69 50.0 1599.0 655.6 76.32 41.1 1742.5 714.4 83.17 32.1
120 120000 33.33 1500.6 615.2 71.62 26.7 1918.8 786.7 91.58 21.9 2091.0 857.3 99.80 17.1
140 140000 38.89 1750.7 717.8 83.56 28.1 2238.6 917.8 106.85 23.1 2439.5 1000.2 116.44 18.0
160 160000 44.44 2000.8 820.3 95.50 33.2 2558.4 1048.9 122.11 27.3 2788.0 1143.1 133.07 21.3
180 180000 50.00 2250.9 922.9 107.44 29.5 2878.2 1180.1 137.38 24.3 3136.5 1286.0 149.71 18.9
200 200000 55.56 2501.0 1025.4 119.37 33.6 3198.0 1311.2 152.64 27.6 3485.0 1428.9 166.34 21.5

Notes:
1. TH Total heat capacity;
2. SH Sensible heat capacity;
3. DP Water pressure drop;
4. Entering air dry bulb temp. 34, entering air wet bulb tem. 28;
5. Entering/leaving water temperature 7/12;
6. Coil face velocity 2.5m/s.

11
5. 3 Cooling coil performance curve

12
5. 4 Heating coil specification

Medium Air inlet temperature


Type Rows
data
-15 -10 -5 0 5 10 15 17 19 21 23 25
40 9.47 8.52 7.58 6.64 5.69 4.75 3.80 3.43 3.06 2.68 2.31 1.90
50 11.4 10.4 9.52 8.57 7.63 6.60 5.73 5.21 4.89 4.61 4.24 3.85
2rows
60 13.3 12.3 11.3 10.4 9.56 8.50 7.66 7.30 6.91 6.52 6.13 5.77
Hot water heating coil

70 15.2 14.2 13.3 12.3 11.5 10.4 9.58 9.19 8.8 8.45 8.02 7.69
40 14.5 13.2 11.7 10.2 8.72 7.25 6.30 5.56 4.93 4.30 3.67 3.15
50 17.6 16.1 14.8 13.2 11.8 10.2 8.92 8.40 7.87 7.35 6.82 6.30
4rows
60 20.6 19.1 17.6 16.1 14.8 13.1 12.3 11.7 11.1 10.5 9.87 9.24
70 23.5 22.0 20.6 19.1 17.7 16.1 15.3 14.8 10.4 10.3 12.9 12.3
40 17.2 15.3 13.5 11.8 10.1 8.42 7.20 6.36 5.64 4.92 4.21 3.61
50 24.3 18.7 17.2 15.3 13.7 11.8 10.2 9.60 9.02 8.40 7.80 7.22
6rows
60 23.9 22.2 20.5 18.8 17.2 15.3 14.0 13.4 12.7 12.0 11.2 10.5
70 27.3 25.6 23.9 22.1 20.6 18.7 17.5 16.9 16.2 15.5 14.7 14.2
heating coil

0.2MPa 12.8 12.4 12.1 11.7 11.3 10.9 10.5 10.3 10.2 10.0 9.87 9.72
1row
Steam

0.3MPa 13.7 13.3 13.0 12.6 12.2 11.8 11.4 11.3 11.1 10.9 10.8 10.6
0.2MPa 23.9 23.2 22.4 21.7 20.9 20.2 19.4 19.1 18.8 18.5 18.2 17.8
2rows
0.3MPa 25.6 24.8 24.1 23.3 22.6 21.8 21.0 20.8 20.5 20.1 19.8 19.5

5. 4 Heating coil performance curve

.
gtemp mp
.
te
erin ing
Ent er
Ent

13
6. Dimension
6.1 Unit dimension

Air volume Cross dimension (mm) Standard Unit Length (mm)


ZK
m3/h m3/s W H h La0 Lb0 Lc0 Ld0 Lcp1 Lcp2 Lcp3 Lcp4
02 2000 0.56 880 980 100 4290 4510 5500 5940 4290 6270 5720 3740
03 3000 0.83 880 980 100 4290 4510 5500 5940 4290 6270 5720 3740
04 4000 1.11 1100 980 100 4290 4510 5500 5940 4290 6270 5720 3740
05 5000 1.39 1430 980 100 4290 4510 5500 5940 4290 6270 5720 3740
06 6000 1.67 1430 980 100 4510 4730 5720 6380 4510 6490 5940 3960
07 7000 1.94 1430 1200 100 4510 4730 5720 6380 4510 6490 5940 3960
08 8000 2.22 1430 1200 100 4510 4730 5720 6380 4510 6490 5940 3960
09 9000 2.50 1430 1200 100 4620 4840 5830 6600 4620 6600 6050 4070
10 10000 2.78 1430 1530 100 4620 5060 6160 6820 4620 6820 6380 4290
12 12000 3.33 1430 1530 100 4620 5060 6160 6820 4620 6820 6380 4290
14 14000 3.89 1760 1530 100 4840 5170 6270 7040 4840 6930 6490 4400
16 16000 4.44 1870 1530 100 4840 5170 6270 7040 4840 6930 6490 4400
18 18000 5.00 1980 1530 100 4840 5170 6270 7040 4840 6930 6490 4400
20 20000 5.56 1980 1640 100 5060 5280 6490 7260 5060 7150 6710 4510
25 25000 6.94 2200 1860 100 5060 5280 6490 7260 5060 7150 6710 4510
30 30000 8.33 2200 2300 100 5280 5720 6930 7920 5280 7590 6930 4950
35 35000 9.72 2420 2300 100 5280 5720 6930 7920 5280 7590 6930 4950
40 40000 11.11 2750 2300 100 5280 5720 6930 7920 5280 7590 6930 4950
45 45000 12.50 2750 2520 100 5280 5720 6930 7920 5280 7590 7150 4950
50 50000 13.89 2970 2520 100 5830 6270 7810 8580 5940 8470 8030 5500
60 60000 16.67 3410 2520 100 5830 6270 7810 8580 5940 8470 8030 5500
70 70000 19.44 3410 2870 120 5940 6380 7920 8800 6060 8580 8140 5610
80 80000 22.22 3960 2870 120 5940 6380 7920 8800 6050 8580 8140 5610
90 90000 25.00 4620 2870 120 5940 6380 7920 8800 6050 8580 8140 5610
100 100000 27.78 4620 3090 120 6160 6710 8470 9020 6270 9130 8580 5940
120 120000 33.33 5720 3130 160 6380 6930 8690 9460 6490 9350 8800 6160
140 140000 38.89 5940 3460 160 6380 6930 8690 9460 6490 9350 8800 6160
160 160000 44.44 6710 3460 160 6380 6930 8690 9460 6490 9350 8800 6160
180 180000 50.00 6160 4120 160 6710 7480 9130 9680 6820 9790 9240 6380
200 200000 55.56 6820 4120 160 6930 7700 9350 10120 6820 10010 9460 6600

14
6.2 Section dimension

Air volume Section Length (mm)


ZK
m3/h m3/s MB OB Fm1 Fm2 ES MF PMF FF AF CC HCH SA AW CM RD HW PE
02 2000 0.56 770 660 1100 1100 660 550 660 880 2860 880 770 1210 3300 1540 1760 1430 2200
03 3000 0.83 770 660 1100 1100 660 550 660 880 2860 880 770 1210 3300 1540 1760 1430 2200
04 4000 1.11 770 660 1100 1100 660 550 660 880 2860 880 770 1210 3300 1540 1760 1430 2200
05 5000 1.39 770 660 1100 1100 660 550 660 880 2860 880 770 1210 3300 1540 1760 1430 2200
06 6000 1.67 770 660 1320 1320 660 550 660 880 2860 880 770 1210 3300 1540 1760 1430 2200
07 7000 1.94 770 660 1320 1320 660 550 660 880 2860 880 770 1210 3300 1540 1760 1430 2200
08 8000 2.22 770 660 1320 1320 660 550 660 880 2860 880 770 1210 3300 1540 1760 1430 2200
09 9000 2.50 770 660 1430 1430 660 550 660 880 2860 880 770 1210 3300 1540 1760 1430 2200
10 10000 2.78 880 770 1430 1430 660 550 660 880 2860 880 770 1210 3300 1650 1760 1430 2200
12 12000 3.33 880 770 1430 1430 660 550 660 880 2860 880 770 1210 3300 1650 1760 1430 2200
14 14000 3.89 880 770 1540 1540 660 550 660 880 2860 880 770 1210 3300 1650 1760 1430 2200
16 16000 4.44 880 770 1540 1540 660 550 660 880 2860 880 770 1210 3300 1650 1760 1430 2200
18 18000 5.00 880 770 1540 1540 660 550 660 880 2860 880 770 1210 3300 1650 1760 1430 2200
20 20000 5.56 990 770 1650 1650 660 550 660 880 2860 880 770 1210 3300 1760 1760 1430 2200
25 25000 6.94 990 770 1650 1650 660 550 660 880 2860 880 770 1210 3300 1760 1760 1430 2200
30 30000 8.33 990 880 1870 1870 660 550 660 880 2860 880 770 1210 3300 1760 1760 1430 2200
35 35000 9.72 990 880 1870 1870 660 550 660 880 2860 880 770 1210 3300 1760 1760 1430 2200
40 40000 11.11 990 880 1870 1870 660 550 660 880 2860 880 770 1210 3300 1760 - 1430 2200
45 45000 12.50 990 880 1870 1870 660 550 660 880 2860 880 770 1210 3300 1760 - 1430 2200
50 50000 13.89 1320 1100 2090 2090 660 550 660 880 2860 880 770 1210 3300 1980 - 1430 2200
60 60000 16.67 1320 1100 2090 2090 660 550 660 880 2860 880 770 1210 3300 1980 - 1430 2200
70 70000 19.44 1320 1100 2200 2200 660 550 660 880 2860 880 770 1210 3300 1980 - 1430 2200
80 80000 22.22 1320 1100 2200 2200 660 550 660 880 2860 880 770 1210 3300 1980 - 1430 2200
90 90000 25.00 1320 1100 2200 2200 660 550 660 880 2860 880 770 1210 3300 1980 - 1430 2200
100 100000 27.78 1540 1320 2200 2200 660 550 660 880 2860 880 770 1210 3300 2200 - 1430 2200
120 120000 33.33 1540 1320 2420 2420 660 550 660 880 2860 880 770 1210 3300 2200 - 1430 2200
140 140000 38.89 1540 1320 2420 2420 660 550 660 880 2860 880 770 1210 3300 2200 - 1430 2200
160 160000 44.44 1540 1320 2420 2420 660 550 660 880 2860 880 770 1210 3300 2200 - 1430 2200
180 180000 50.00 1760 1430 2530 2530 660 550 660 880 2860 880 770 1210 3300 2200 - 1430 2200
200 200000 55.56 1760 1430 2750 2750 660 550 660 880 2860 880 770 1210 3300 2200 - 1430 2200

15
7. AHU combination models
7.1 Model A

Characteristic :
The fan postposition, that all of the handling equipment are in the negative pressure section. The unit's length is
short, and convenient for installation.This scheme is applicable for the general systems which have no cleanliness
request or the clean systems that the unit's length is limited.
As the figure shown, it is the basic model of the A combination scheme , basic function section include: mixing box,
pre-filter , main filter, cooling coil, heater, humidifier , fan and motor, etc. On this basis , users can also increase or
decrease other function sections according to need.

7.2 Model B

Characteristic :
The fan preposition, that the main filter and other main parts are in the positive pressure section , this is
advantageous to shelter the coil and drain off the condensed water . This scheme is broadly applicable for the clean
air conditioning system.
As the figure shown, it is the basic model of the B combination scheme , basic function section include: mixing box,
fan and motor , diffuser, pre-filter , main filter, cooling coil, heater, humidifier, etc. On this basis , users can also
increase or decrease other function sections according to need.

16
7.3 Model C

Characteristic :
The fan placed in middle position, that the main filter is in the positive pressure section and other parts are in the
negative pressure section. This scheme is extensively applicable for the clean air conditioning system.
As the figure shown, it is the basic model of the C combination scheme , basic function section include: mixing box,
pre-filter, cooling coil, heater, humidifier, fan and motor, diffuser, main filter and outlet section, etc. On this basis ,
users can also increase or decrease other function sections according to need.

7.4 Model D

Characteristic :
Having supply fan and return fan, the system can realize variable fresh air flow running. This scheme is applicable for
the general systems which have no cleanliness request or comfort air conditioning system .
As the figure shown, it is the basic model of the D combination scheme , basic function section include: return fan,
combined mixing box, pre-filter, main filter, cooling coil, heater , humidifier, supply fan ,etc. On this basis , users can
also increase or decrease other function sections according to need.

17
8. AHU commended projects
8.1 Model CP-01

Characteristic :
Adopt secondary return air, can save the cooling capacity and reheat capacity effectively. It is used broadly by the
air conditioning system which have temperature and humidity control requirement and whose design delivery air
temperature are notably higher than design dewpoint temperature.
This scheme is also suitable for the C combination scheme.

8.2 Model CP-02

Characteristic :
Adopt fresh air pretreatment, the function of the precooling coil is dehumidification, the recooling coil is used
to adjust the temperature of delivery air, which can save cooling and reheat capacity effectively. This scheme is
applicable to clean air conditioning system whose design temperature difference of delivery air is much small.
This scheme is suitable for A, C combination scheme too.

18
8.3 Model CP-03

Characteristic :
Adopt fresh air pre-filter, can prolong the life-span of the pre-filter effectively. This scheme is widely applicable to
clean air conditioning system without central fresh air handling unit.
This scheme is also suitable for A, C combination scheme.

8.4 Model CP-04

Characteristic :
Locate the heater in the air outlet ,can save the heater expenses and compress unit's length effectively.
This scheme is widely applicable to the clean air conditioning system with small fresh air proportion or central fresh
air handling unit.
This scheme is suitable for the C combination scheme too .

19
9. Combination options

MB OB FM1
Mixing Outlet Fan& Motor
Box Box Section

FM2 ES MF
Fan& Motor Empty Main
Section Section Filter

PMF FF AF
Pre-filter & Final Ambient
Main filter Filter Filter

20
CC HCH SA
Cooling Heating Coil Sound
Coil & Humidifier Attenuator

AW CM
Air Combined
Washer Mixing box

RD HW PE
Rotary Heat Plate heat
Dehumidifier Wheel Exchanger

21
10. Motor power input
Unit: kW
Air flow rate Fan total ressure (Pa)
ZK
m3/h m3/s 600 800 1000 1200 1400 1600
02 2000 0.56 1.1 1.1 1.5 1.5 2.2 3.0
03 3000 0.83 1.5 1.5 2.2 2.2 2.2 3.0
04 4000 1.11 1.5 2.2 3.0 3.0 3.0 4.0
05 5000 1.39 2.2 3.0 3.0 3.0 4.0 4.0
06 6000 1.67 2.2 3.0 4.0 4.0 4.0 5.5
07 7000 1.94 3.0 4.0 4.0 4.0 5.5 5.5
08 8000 2.22 3.0 4.0 4.0 5.5 5.5 5.5
09 9000 2.50 4.0 4.0 5.5 5.5 5.5 7.5
10 10000 2.78 4.0 5.5 5.5 5.5 7.5 7.5
12 12000 3.33 4.0 5.5 7.5 7.5 7.5 11
14 14000 3.89 5.5 7.5 7.5 7.5 11 11
16 16000 4.44 7.5 7.5 11 11 11 15
18 18000 5.00 7.5 11 11 11 11 15
20 20000 5.56 7.5 11 11 11 15 15
25 25000 6.94 11 11 15 15 15 18.5
30 30000 8.33 11 11 15 18.5 18.5 22
35 35000 9.72 11 15 15 18.5 22 22
40 40000 11.11 15 18.5 22 22 30 30
45 45000 12.50 15 18.5 22 30 30 30
50 50000 13.89 15 18.5 22 30 30 30
60 60000 16.67 22 22 30 30 37 37
70 70000 19.44 22 30 30 37 37 45
80 80000 22.22 30 30 37 45 45 55
90 90000 25.00 30 30 37 45 55 55
100 100000 27.78 37 37 45 55 55 75
120 120000 33.33 37 37 45 55 75 75
140 140000 38.89 45 55 55 75 75 90
160 160000 44.44 55 75 75 90 90 110
180 180000 50.00 75 75 90 90 110 160
200 200000 55.56 75 90 90 110 160 160

11. Parts resistance


Description Resistance (Pa) Description Resistance (Pa)
Damper 20 Cooling coil (4rows) 130
Pre-filter 50~100 Cooling coil (6rows) 190
Main filter 100~250 Cooling coil (8rows) 260
Ambient filter 150~350 Cooling coil (10rows) 320
Eliminator 120 Steam heating coil (1row) 25
Sound attenuator 40 Hot water coil (2rows) 50

22
12. Quick selection guide
Steps Selection basis Selection principle
The different unit scheme is suitable for the different system. User can select the
Confirm
Customer request scheme suited for the project.
combination
project charactor According to the needs, on the basis of all kinds of basic schemes ,User can increase
scheme
or decrease corresponding function section.
According to the unit's rating air flow the design air flow, select suitable unit ;
Unit's type is according to tabulating , namely ZK02- 200 is expressed; The same
Confirm unit
Design air flow type of unit be used for lower air flow rate, not recommended for higher air flow.
specification
The unit can be used for higher air flow rate (10% higher) in actual operation, and
the cooling capacity needs to make corresponding revision.
Design air According to the unit's total rated cooling capacity (TH) the design total cooling
flow entering capacity, confirm the rows of the cooling coil . In this manual, rated cooling capacity
Cooling coil
air condition, is obtained by taking the standard entering air condition and the standard inlet-
selection
chilled water outlet water condition. When the design condition is different from the standard
temperature condition, should adopt essential revision. Consult the coefficient parameter list.
According to heater heating capacity the biggest design heating capacity, confirm
the rows of the hot water or the steam heating coil. When the heater is not only used
Design heating as mainly heating in winter but also used as reheating in summer, should regard
capacity, entering the bigger one of the two as the selection basis .
Heater air condition, In the same way, the capacity of heating coil is obtained by taking the standard
selection hot water condition, when the actual used condition is different from the standard condition,
temperature or should adopt essential revision. Consult the coefficient parameter list.
steam pressure The hot water heater should be first selection, the steam heater ( 0.3MPa )is
secondly. The electrical heater should be used as the auxiliary heating, or the main
heater in some small unit.
ZK series air handling unit can supply humidifier of different type. Users need to
confirm the type of humidifier and humidity capacity.
Design humidity
Humidifier While there are steam source, should have priority to adopt the steam humidifier,
caacity, actual
selection secondly it is electrode humidifier or electric heat type humidifier. When there
condition
is no steam and system situation allow , can adopt evaporative humidifier(wet-
membrane, air washer etc.).
General air handling units(not cleaning units) can adopt panel pre-filter (G4 ) or
bag pre-filter (G4 ) or panel pre-filter (G4 ) + bag filter (F7 ) . Cleaning air handling
units can adopt pre-filter (G4, panel or bag) + main filter (F8, bag ), and the main
Confirm the customer's
filters should be located behind the fan (namely B , C scheme). Generally make up air
scheme of needs or process
units(MAU) adopt third class filters, namely panel pre-filter (G4 ) + bag main filters
filter conditions
(F8 ) + box final filter (H11), and the main filter and the final filter should be located
behind the fan. As to dust content high situation, it is recommended to adopt
ambient filter.
According to the duct loss, confirm external static pressure Pj . According to
Confirm the the "Parts Resistance Data" , check main parts resistance P1, P2, P3. External
External static
power of static pressure and section resistance summation, namely fan total pressure Pt:
pressure
motor Pt=Py+P1+P2+P3; According to design air flow and Pt, consult the "motor power
list" , can have the power of motor.
After confirming the combination scheme, can check unit's transect size(W*H) ,
then check the basis unit's length (such as Lb0). According to the concrete function
Confirm the Combination requirement, increase and decrease the functional section on the basis of basic
unit overal scheme, unit type , and revise the length. According to the condition of engine room, check
dimension dimension unit's overall dimension whether meets the demands. If it is not allowed by the spot
condition and have to adjust the overall dimension of unit on a large scale, please
contact our representative, we can offer the nonstandard design plan further.
Fresh air damper and return air damper are the unit's standard configuration.
According to the spot condition ,the air inlet's position and size can be adjusted
reasonably. The position of pipe connection and the position of the access door can
be adjusted reasonably according to the spot condition before producing.
Customer's
Others Unit's noisel have very great relation with fan total pressure , so it isn't definite. If
request
users need, we can offer noise value at the inlet and outlet that the units make in the
concrete design condition, for users to calculate eliminating noise value .
If users need to adopt sound absorber, should be priority to adopt the duct sound
absorber, sound attenuator section in the units should be secondly.