With the clear understanding capability of its client, Bueco focuses on the air cooled
water chiller and heat pump, water cooled water chiller and heat pump, air handling
unit, fan coil unit, rooftop packaged unit and other HVAC accessories required by
customers.
All Bueco products have different certificates, CE, AHRI, CCC, China National Test Report.
ISO9001:2008 and ISO 14001:2004 certified for the company.
Thanks for the trust and supports of our clients, Bueco has been delivered to Algeria,
Nigeria, Ethopia, Angola, South Africa, Indonesia, Cambodia, Philippines, Thailand,
Malaysia, South Korea, Japan, Pakistan, India, Sri Lanka, Mongolia etc.
With the conception, creation in techology and value, Bueco is growing up with its
clients, workers with quality products and quality life.
Certificate/License
Enterprise Qualification
The group is operated with the conception of Morality first, humanity first and Customer first and in
team work, the quality management system is customer oriented, supplies customers with products of high
technology, high quality and efficient service.
Its one of the companies who got the first lot of license of refrigeration equipment production in
China. We got the national 1st level qualification license on mechanical, electrical equipment installation,
2nd level qualification license on air purification engineering, hygiene license on Sheet Molding Compound
(SMC) product, and took the lead in the award of the license of pressure vessel design and manufacture.
The company is ISO9001, ISO14001, QHSAS18001 certified. Our air conditioning products have the
National Certificate of Refrigeration Equipment Production, 3C China Compulsory Certificate, CRAA China
Refrigeration Industry Performance Certificate, cooling tower product is certified as China Water Saving
Product and air handling unit is AHRI certified.
Contents
1. Nomenclature 04
2. How to tell the water pipe connection direction, right or left? 04
3. About the AHU 05
4. Key components feature 05
5. Performance data 10
6. Dimension 14
7. AHU combination models 16
8. AHU commended projects 18
9. Combination option 20
10. Motor power input 22
11. Parts resistance 22
12. Quick selection guide 23
1. Nomenclature
ZK XX X X P
Pharmaceutical
Left
Right
Air intake
To look at the AHU from the air intake direction, it's right type if the chilled water pipe is at the right
side, and vice versa.
04
3. About the AHU
Its a complete system solution with unique advantage for the clean operation room
air handling unit, including machine and control integration, strong and week electricity
integration, convenient modular combination, positive pressure control, filter solution, bacteria
elimination and energy saving.
05
4.3 Cooling & heating coil
Standard coils are constructed from copper tubes mechanically
bonded to aluminium fins, with threaded copper headers, all
contained in a galvanised steel frame.
Coil options are:
--Anti-corrosion coated coil. Copper & aluminum coil
--Steam distributor heating coils.
--Evaporator coils.
--Copper fins.
--Tinned copper fins adjustment. Base frames are completely isolated
from the unit casing to avoid vibration in cabinet.
All coils are computer selected to achieve the optimum psychrometric Copper & Copper coil
efficiency with low air and water pressure drops.
All coils are leak tested at 28bar with a maximum design pressure of 25
bar.
Condensate pans are a "dry pan" design, manufactured from stainless
steel.
Aluminium droplet eliminators are fitted after cooling coils when the air
velocity exceeds 2.5m/s. Anti freezing device
Antifreezing device can be added to protect the unit when necessary.
The steam heating coil has tube in tube design, liquid is separate from
vapor, no harm to coil due to water hammer effect, with builtin steam
distributor, the steam is distributed equally and efficiency is higher.
Standard steam heating coil is made of copper tube with anti corrosion
hydrophic aluminum fin.
Steam heating coil
4.4 Humidifiers
4.4.1 Steam humidifier
At the heart of the humidifier is an all-in-one steam connection unit
featuring a new rotary disk valve, which is linked to the tried-and-
tested steam distribution system and its patented steam nozzles. The
humidifier has one or more stainless steel distribution pipes.
06
4.4.3 Evaporative humidifier
A viscose-coated evaporating pack is moistened with water, used tap
water or circulated by an internally mounted pump from a stainless
steel tank.
07
4.6. 2 Thermal wheel recovery
Available with a hygroscopic or non-hygroscopic rotor for recovering
and transferring heat energy from the exhaust to the supply air
streams.
4.7 Filters
The following forms of filter can be supplied:
4.7.1 Prefilters
Synthetic or glass-fibre media panel filters, class G2 to G4 arranged in
H
galvanised steel frames or sliding rails.
4.7.2 Main filters
Synthetic or glass-fibre media bag filters, class F5 to F9 arranged in
galvanised steel and luminium alloy frames with gaskets to avoid air
bypass.
08
4.8 Ultraviolet lamp
Ultraviolet lamp only effective on the bacteria on object surface, it
can be used to eliminate the bacteria on the surface of filter, coil and
drain pan. C wave band 265nm ultraviolet lamp with quartz glass
lamp tube of long lifetime. There is one protection switch on the
access door of ultraviolet lamp, the lamp will be switched off when
the door is open for safety.
4.9 Dampers
Damper shall have high strength extruded aluminium blade, ABS
drive-gear, and shall be mounted internally / externally. The blades
shall be fitted with "O"-type sealing gasket.
Shafts and control rods shall be of steel or copper and shall be
purpose designed to suit the actuators. The damper shall be
controlled by means of manual or motorized.
Final dimension to be specified by customer.
B. Adopts VFD motor to control the air flow rate, saves energy.
C. Set the operation condition with the VFD system
Control system customization is available. User's PC
09
5. Performance Data
5.1 Cooling coil specification return air condition
Air volume 4 Rows 6 Rows 8 Rows
ZK Flow- Flow- Flow- DP
TH SH DP TH SH DP TH SH
m3/h m3/s rate rate rate kPa
kW kW kPa kW kW kPa kW kW
l/s l/s l/s
02 2000 0.56 12.2 8.2 0.58 7.8 15.6 10.1 0.74 10.6 17.0 10.9 0.81 11.8
03 3000 0.83 18.3 12.3 0.87 7.8 23.4 15.2 1.12 10.6 25.5 16.3 1.22 11.8
04 4000 1.11 24.4 16.3 1.16 12.9 31.2 20.3 1.49 17.4 34.0 21.8 1.62 19.4
05 5000 1.39 30.5 20.4 1.46 20.0 39.0 25.4 1.86 27.0 42.5 27.2 2.03 30.0
06 6000 1.67 36.6 24.5 1.75 18.3 46.8 30.4 2.23 24.8 51.0 32.6 2.43 27.6
07 7000 1.94 42.7 28.6 2.04 19.5 54.6 35.5 2.61 26.4 59.5 38.1 2.84 29.3
08 8000 2.22 48.8 32.7 2.33 20.4 62.4 40.6 2.98 27.6 68.0 43.5 3.25 30.7
09 9000 2.50 54.9 36.8 2.62 21.2 70.2 45.6 3.35 28.7 76.5 49.0 3.65 31.9
10 10000 2.78 61.0 40.9 2.91 20.0 78.0 50.7 3.72 27.0 85.0 54.4 4.06 12.8
12 12000 3.33 73.2 49.0 3.49 21.2 93.6 60.8 4.47 28.7 102.0 65.3 4.87 13.6
14 14000 3.89 85.4 57.2 4.08 27.8 109.2 71.0 5.21 16.0 119.0 76.2 5.68 17.8
16 16000 4.44 97.6 65.4 4.66 30.2 124.8 81.1 5.96 17.4 136.0 87.0 6.49 19.4
18 18000 5.00 109.8 73.6 5.24 14.9 140.4 91.3 6.70 20.1 153.0 97.9 7.30 22.4
20 20000 5.56 122.0 81.7 5.82 16.9 156.0 101.4 7.45 22.9 170.0 108.8 8.11 25.5
25 25000 6.94 152.5 102.2 7.28 16.9 195.0 126.8 9.31 22.9 212.5 136.0 10.14 25.5
30 30000 8.33 183.0 122.6 8.73 16.9 234.0 152.1 11.17 22.9 255.0 163.2 12.17 25.5
35 35000 9.72 213.5 143.0 10.19 18.6 273.0 177.5 13.03 25.1 297.5 190.4 14.20 27.9
40 40000 11.11 244.0 163.5 11.65 23.0 312.0 202.8 14.89 31.1 340.0 217.6 16.23 14.7
45 45000 12.50 274.5 183.9 13.10 23.1 351.0 228.2 16.75 19.0 382.5 244.8 18.26 14.8
50 50000 13.89 305.0 204.4 14.56 25.2 390.0 253.5 18.61 20.7 425.0 272.0 20.29 16.1
60 60000 16.67 366.0 245.2 17.47 31.5 468.0 304.2 22.34 25.9 510.0 326.4 24.34 20.2
70 70000 19.44 427.0 286.1 20.38 14.4 546.0 354.9 26.06 27.7 595.0 380.8 28.40 21.6
80 80000 22.22 488.0 327.0 23.29 16.9 624.0 405.6 29.78 32.7 680.0 435.2 32.46 25.5
90 90000 25.00 549.0 367.8 26.20 19.6 702.0 456.3 33.51 37.8 765.0 489.6 36.51 29.5
100 100000 27.78 610.0 408.7 29.12 20.7 780.0 507.0 37.23 39.9 850.0 544.0 40.57 31.1
120 120000 33.33 732.0 490.4 34.94 25.9 936.0 608.4 44.68 35.0 1020.0 652.8 48.68 38.9
140 140000 38.89 854.0 572.2 40.76 27.3 1092.0 709.8 52.12 36.9 1190.0 761.6 56.80 41.1
160 160000 44.44 976.0 653.9 46.58 32.2 1248.0 811.2 59.57 43.5 1360.0 870.4 64.91 20.6
180 180000 50.00 1098.0 735.7 52.41 28.6 1404.0 912.6 67.01 38.7 1530.0 979.2 73.03 18.4
200 200000 55.56 1220.0 817.4 58.23 32.6 1560.0 1014.0 74.46 44.4 1700.0 1088.0 81.14 20.9
Notes:
1. TH Total heat capacity;
2. SH Sensible heat capacity;
3. DP Water pressure drop;
4. Entering air dry bulb temp. 27, entering air wet bulb tem. 19.5;
5. Entering/leaving water temperature 7/12;
6. Coil face velocity 2.5m/s.
10
5.2 Cooling coil specification fresh air condition
Air volume 4 Rows 6 Rows 8 Rows
ZK Flow- Flow- Flow- DP
TH SH DP TH SH DP TH SH
m3/h m3/s rate rate rate kPa
kW kW kPa kW kW kPa kW kW
l/s l/s l/s
02 2000 0.56 25.0 10.3 1.19 18.9 32.0 13.1 1.53 25.6 34.9 14.3 1.66 28.4
03 3000 0.83 37.5 15.4 1.79 18.9 48.0 19.7 2.29 25.6 52.3 21.4 2.50 28.4
04 4000 1.11 50.0 20.5 2.39 31.1 64.0 26.2 3.05 18.0 69.7 28.6 3.33 20.0
05 5000 1.39 62.5 25.6 2.98 20.6 80.0 32.8 3.82 27.9 87.1 35.7 4.16 31.0
06 6000 1.67 75.0 30.8 3.58 18.9 95.9 39.3 4.58 25.6 104.6 42.9 4.99 28.4
07 7000 1.94 87.5 35.9 4.18 20.1 111.9 45.9 5.34 27.2 122.0 50.0 5.82 30.2
08 8000 2.22 100.0 41.0 4.77 21.0 127.9 52.4 6.11 28.5 139.4 57.2 6.65 31.7
09 9000 2.50 112.5 46.1 5.37 21.9 143.9 59.0 6.87 29.6 156.8 64.3 7.49 14.0
10 10000 2.78 125.1 51.3 5.97 20.6 159.9 65.6 7.63 27.9 174.3 71.4 8.32 13.2
12 12000 3.33 150.1 61.5 7.16 21.9 191.9 78.7 9.16 29.6 209.1 85.7 9.98 14.0
14 14000 3.89 175.1 71.8 8.36 28.6 223.9 91.8 10.68 23.5 244.0 100.0 11.64 18.3
16 16000 4.44 200.1 82.0 9.55 31.1 255.8 104.9 12.21 25.6 278.8 114.3 13.31 20.0
18 18000 5.00 225.1 92.3 10.74 15.3 287.8 118.0 13.76 29.6 313.7 128.6 14.97 23.1
20 20000 5.56 250.1 102.5 11.94 17.5 319.8 131.1 15.26 33.7 348.5 142.9 16.63 26.3
25 25000 6.94 312.6 128.2 14.92 17.5 399.8 163.9 19.08 33.7 435.6 178.6 20.79 26.3
30 30000 8.33 375.2 153.8 17.91 17.5 479.7 196.7 22.90 33.7 522.8 214.3 24.95 26.3
35 35000 9.72 437.7 179.4 20.89 19.1 559.8 229.5 26.71 36.9 609.9 250.0 29.11 28.8
40 40000 11.11 500.2 205.1 23.87 23.7 639.6 262.2 30.53 45.6 697.0 285.8 33.27 35.6
45 45000 12.50 562.7 230.7 26.86 23.8 719.6 295.0 34.34 45.9 784.1 321.5 37.43 35.8
50 50000 13.89 625.3 256.4 29.84 25.9 799.5 327.8 38.16 21.3 871.3 357.2 41.58 39.0
60 60000 16.67 750.3 307.6 35.81 32.5 959.4 393.4 45.79 26.7 1045.5 428.7 49.90 20.8
70 70000 19.44 875.4 358.9 41.78 34.8 1119.3 458.9 53.42 28.6 1219.8 500.1 58.22 22.3
80 80000 22.22 1000.4 410.2 47.75 41.0 1279.2 524.5 61.06 33.7 1394.0 571.5 66.54 26.3
90 90000 25.00 1125.5 461.4 53.72 47.4 1439.1 590.0 68.69 38.9 1568.3 643.0 74.85 30.4
100 100000 27.78 1250.5 512.7 59.69 50.0 1599.0 655.6 76.32 41.1 1742.5 714.4 83.17 32.1
120 120000 33.33 1500.6 615.2 71.62 26.7 1918.8 786.7 91.58 21.9 2091.0 857.3 99.80 17.1
140 140000 38.89 1750.7 717.8 83.56 28.1 2238.6 917.8 106.85 23.1 2439.5 1000.2 116.44 18.0
160 160000 44.44 2000.8 820.3 95.50 33.2 2558.4 1048.9 122.11 27.3 2788.0 1143.1 133.07 21.3
180 180000 50.00 2250.9 922.9 107.44 29.5 2878.2 1180.1 137.38 24.3 3136.5 1286.0 149.71 18.9
200 200000 55.56 2501.0 1025.4 119.37 33.6 3198.0 1311.2 152.64 27.6 3485.0 1428.9 166.34 21.5
Notes:
1. TH Total heat capacity;
2. SH Sensible heat capacity;
3. DP Water pressure drop;
4. Entering air dry bulb temp. 34, entering air wet bulb tem. 28;
5. Entering/leaving water temperature 7/12;
6. Coil face velocity 2.5m/s.
11
5. 3 Cooling coil performance curve
12
5. 4 Heating coil specification
70 15.2 14.2 13.3 12.3 11.5 10.4 9.58 9.19 8.8 8.45 8.02 7.69
40 14.5 13.2 11.7 10.2 8.72 7.25 6.30 5.56 4.93 4.30 3.67 3.15
50 17.6 16.1 14.8 13.2 11.8 10.2 8.92 8.40 7.87 7.35 6.82 6.30
4rows
60 20.6 19.1 17.6 16.1 14.8 13.1 12.3 11.7 11.1 10.5 9.87 9.24
70 23.5 22.0 20.6 19.1 17.7 16.1 15.3 14.8 10.4 10.3 12.9 12.3
40 17.2 15.3 13.5 11.8 10.1 8.42 7.20 6.36 5.64 4.92 4.21 3.61
50 24.3 18.7 17.2 15.3 13.7 11.8 10.2 9.60 9.02 8.40 7.80 7.22
6rows
60 23.9 22.2 20.5 18.8 17.2 15.3 14.0 13.4 12.7 12.0 11.2 10.5
70 27.3 25.6 23.9 22.1 20.6 18.7 17.5 16.9 16.2 15.5 14.7 14.2
heating coil
0.2MPa 12.8 12.4 12.1 11.7 11.3 10.9 10.5 10.3 10.2 10.0 9.87 9.72
1row
Steam
0.3MPa 13.7 13.3 13.0 12.6 12.2 11.8 11.4 11.3 11.1 10.9 10.8 10.6
0.2MPa 23.9 23.2 22.4 21.7 20.9 20.2 19.4 19.1 18.8 18.5 18.2 17.8
2rows
0.3MPa 25.6 24.8 24.1 23.3 22.6 21.8 21.0 20.8 20.5 20.1 19.8 19.5
.
gtemp mp
.
te
erin ing
Ent er
Ent
13
6. Dimension
6.1 Unit dimension
14
6.2 Section dimension
15
7. AHU combination models
7.1 Model A
Characteristic :
The fan postposition, that all of the handling equipment are in the negative pressure section. The unit's length is
short, and convenient for installation.This scheme is applicable for the general systems which have no cleanliness
request or the clean systems that the unit's length is limited.
As the figure shown, it is the basic model of the A combination scheme , basic function section include: mixing box,
pre-filter , main filter, cooling coil, heater, humidifier , fan and motor, etc. On this basis , users can also increase or
decrease other function sections according to need.
7.2 Model B
Characteristic :
The fan preposition, that the main filter and other main parts are in the positive pressure section , this is
advantageous to shelter the coil and drain off the condensed water . This scheme is broadly applicable for the clean
air conditioning system.
As the figure shown, it is the basic model of the B combination scheme , basic function section include: mixing box,
fan and motor , diffuser, pre-filter , main filter, cooling coil, heater, humidifier, etc. On this basis , users can also
increase or decrease other function sections according to need.
16
7.3 Model C
Characteristic :
The fan placed in middle position, that the main filter is in the positive pressure section and other parts are in the
negative pressure section. This scheme is extensively applicable for the clean air conditioning system.
As the figure shown, it is the basic model of the C combination scheme , basic function section include: mixing box,
pre-filter, cooling coil, heater, humidifier, fan and motor, diffuser, main filter and outlet section, etc. On this basis ,
users can also increase or decrease other function sections according to need.
7.4 Model D
Characteristic :
Having supply fan and return fan, the system can realize variable fresh air flow running. This scheme is applicable for
the general systems which have no cleanliness request or comfort air conditioning system .
As the figure shown, it is the basic model of the D combination scheme , basic function section include: return fan,
combined mixing box, pre-filter, main filter, cooling coil, heater , humidifier, supply fan ,etc. On this basis , users can
also increase or decrease other function sections according to need.
17
8. AHU commended projects
8.1 Model CP-01
Characteristic :
Adopt secondary return air, can save the cooling capacity and reheat capacity effectively. It is used broadly by the
air conditioning system which have temperature and humidity control requirement and whose design delivery air
temperature are notably higher than design dewpoint temperature.
This scheme is also suitable for the C combination scheme.
Characteristic :
Adopt fresh air pretreatment, the function of the precooling coil is dehumidification, the recooling coil is used
to adjust the temperature of delivery air, which can save cooling and reheat capacity effectively. This scheme is
applicable to clean air conditioning system whose design temperature difference of delivery air is much small.
This scheme is suitable for A, C combination scheme too.
18
8.3 Model CP-03
Characteristic :
Adopt fresh air pre-filter, can prolong the life-span of the pre-filter effectively. This scheme is widely applicable to
clean air conditioning system without central fresh air handling unit.
This scheme is also suitable for A, C combination scheme.
Characteristic :
Locate the heater in the air outlet ,can save the heater expenses and compress unit's length effectively.
This scheme is widely applicable to the clean air conditioning system with small fresh air proportion or central fresh
air handling unit.
This scheme is suitable for the C combination scheme too .
19
9. Combination options
MB OB FM1
Mixing Outlet Fan& Motor
Box Box Section
FM2 ES MF
Fan& Motor Empty Main
Section Section Filter
PMF FF AF
Pre-filter & Final Ambient
Main filter Filter Filter
20
CC HCH SA
Cooling Heating Coil Sound
Coil & Humidifier Attenuator
AW CM
Air Combined
Washer Mixing box
RD HW PE
Rotary Heat Plate heat
Dehumidifier Wheel Exchanger
21
10. Motor power input
Unit: kW
Air flow rate Fan total ressure (Pa)
ZK
m3/h m3/s 600 800 1000 1200 1400 1600
02 2000 0.56 1.1 1.1 1.5 1.5 2.2 3.0
03 3000 0.83 1.5 1.5 2.2 2.2 2.2 3.0
04 4000 1.11 1.5 2.2 3.0 3.0 3.0 4.0
05 5000 1.39 2.2 3.0 3.0 3.0 4.0 4.0
06 6000 1.67 2.2 3.0 4.0 4.0 4.0 5.5
07 7000 1.94 3.0 4.0 4.0 4.0 5.5 5.5
08 8000 2.22 3.0 4.0 4.0 5.5 5.5 5.5
09 9000 2.50 4.0 4.0 5.5 5.5 5.5 7.5
10 10000 2.78 4.0 5.5 5.5 5.5 7.5 7.5
12 12000 3.33 4.0 5.5 7.5 7.5 7.5 11
14 14000 3.89 5.5 7.5 7.5 7.5 11 11
16 16000 4.44 7.5 7.5 11 11 11 15
18 18000 5.00 7.5 11 11 11 11 15
20 20000 5.56 7.5 11 11 11 15 15
25 25000 6.94 11 11 15 15 15 18.5
30 30000 8.33 11 11 15 18.5 18.5 22
35 35000 9.72 11 15 15 18.5 22 22
40 40000 11.11 15 18.5 22 22 30 30
45 45000 12.50 15 18.5 22 30 30 30
50 50000 13.89 15 18.5 22 30 30 30
60 60000 16.67 22 22 30 30 37 37
70 70000 19.44 22 30 30 37 37 45
80 80000 22.22 30 30 37 45 45 55
90 90000 25.00 30 30 37 45 55 55
100 100000 27.78 37 37 45 55 55 75
120 120000 33.33 37 37 45 55 75 75
140 140000 38.89 45 55 55 75 75 90
160 160000 44.44 55 75 75 90 90 110
180 180000 50.00 75 75 90 90 110 160
200 200000 55.56 75 90 90 110 160 160
22
12. Quick selection guide
Steps Selection basis Selection principle
The different unit scheme is suitable for the different system. User can select the
Confirm
Customer request scheme suited for the project.
combination
project charactor According to the needs, on the basis of all kinds of basic schemes ,User can increase
scheme
or decrease corresponding function section.
According to the unit's rating air flow the design air flow, select suitable unit ;
Unit's type is according to tabulating , namely ZK02- 200 is expressed; The same
Confirm unit
Design air flow type of unit be used for lower air flow rate, not recommended for higher air flow.
specification
The unit can be used for higher air flow rate (10% higher) in actual operation, and
the cooling capacity needs to make corresponding revision.
Design air According to the unit's total rated cooling capacity (TH) the design total cooling
flow entering capacity, confirm the rows of the cooling coil . In this manual, rated cooling capacity
Cooling coil
air condition, is obtained by taking the standard entering air condition and the standard inlet-
selection
chilled water outlet water condition. When the design condition is different from the standard
temperature condition, should adopt essential revision. Consult the coefficient parameter list.
According to heater heating capacity the biggest design heating capacity, confirm
the rows of the hot water or the steam heating coil. When the heater is not only used
Design heating as mainly heating in winter but also used as reheating in summer, should regard
capacity, entering the bigger one of the two as the selection basis .
Heater air condition, In the same way, the capacity of heating coil is obtained by taking the standard
selection hot water condition, when the actual used condition is different from the standard condition,
temperature or should adopt essential revision. Consult the coefficient parameter list.
steam pressure The hot water heater should be first selection, the steam heater ( 0.3MPa )is
secondly. The electrical heater should be used as the auxiliary heating, or the main
heater in some small unit.
ZK series air handling unit can supply humidifier of different type. Users need to
confirm the type of humidifier and humidity capacity.
Design humidity
Humidifier While there are steam source, should have priority to adopt the steam humidifier,
caacity, actual
selection secondly it is electrode humidifier or electric heat type humidifier. When there
condition
is no steam and system situation allow , can adopt evaporative humidifier(wet-
membrane, air washer etc.).
General air handling units(not cleaning units) can adopt panel pre-filter (G4 ) or
bag pre-filter (G4 ) or panel pre-filter (G4 ) + bag filter (F7 ) . Cleaning air handling
units can adopt pre-filter (G4, panel or bag) + main filter (F8, bag ), and the main
Confirm the customer's
filters should be located behind the fan (namely B , C scheme). Generally make up air
scheme of needs or process
units(MAU) adopt third class filters, namely panel pre-filter (G4 ) + bag main filters
filter conditions
(F8 ) + box final filter (H11), and the main filter and the final filter should be located
behind the fan. As to dust content high situation, it is recommended to adopt
ambient filter.
According to the duct loss, confirm external static pressure Pj . According to
Confirm the the "Parts Resistance Data" , check main parts resistance P1, P2, P3. External
External static
power of static pressure and section resistance summation, namely fan total pressure Pt:
pressure
motor Pt=Py+P1+P2+P3; According to design air flow and Pt, consult the "motor power
list" , can have the power of motor.
After confirming the combination scheme, can check unit's transect size(W*H) ,
then check the basis unit's length (such as Lb0). According to the concrete function
Confirm the Combination requirement, increase and decrease the functional section on the basis of basic
unit overal scheme, unit type , and revise the length. According to the condition of engine room, check
dimension dimension unit's overall dimension whether meets the demands. If it is not allowed by the spot
condition and have to adjust the overall dimension of unit on a large scale, please
contact our representative, we can offer the nonstandard design plan further.
Fresh air damper and return air damper are the unit's standard configuration.
According to the spot condition ,the air inlet's position and size can be adjusted
reasonably. The position of pipe connection and the position of the access door can
be adjusted reasonably according to the spot condition before producing.
Customer's
Others Unit's noisel have very great relation with fan total pressure , so it isn't definite. If
request
users need, we can offer noise value at the inlet and outlet that the units make in the
concrete design condition, for users to calculate eliminating noise value .
If users need to adopt sound absorber, should be priority to adopt the duct sound
absorber, sound attenuator section in the units should be secondly.
23
BUECO CO., LTD.
Office: Room No. 1-2276-6, Jinqiao International Building, Erhuandong Road,
Licheng District, Jinan, Shandong, China
Factory: Tianqu Industrial Park, Dezhou, Shandong, China
Tel: 0086 531 86955489
Mob: 0086 13708931818
Email: Buecoltd@126.com
www.bueco.com.cn