Académique Documents
Professionnel Documents
Culture Documents
NovelSats Modulator NS1000 More information can be found at: Gigabit Ethernet, E1/T1, ASI interfaces
NovelSats Demodulator NS2000 www.novelsat.com 24V/48V integrated BUC feeder
NovelSats Redundancy Switch NSR1000 Or contact: sales@novelsat.com Supports N+1 redundancy
Baseband
DVB-S2 NS3 Interfaces
Inner code BCH Inner code BCH Maximum rate: bidirectional 730Mbps (365 Mbps)
Outer code LDPC Outer code LDPC Physical Interfaces:
QPSK 1/4, 1/3, 2/5, 1/2, 3/5, 2/3, QPSK 1/4, 1/3, 2/5, 13/30, 7/15, 1/2, 8/15, 17/30, GbE 10/100/1000 Base-T, E1/T1, 2 x ASI, SFP
3/4, 4/5, 5/6, 8/9, 9/10 3/5, 19/30, 2/3, 32/45, 3/4, 4/5, 5/6, 8/9, Supported encapsulation:
9/10
- NovelSat Proprietary Encapsulation (NSPE),
8PSK 3/5, 2/3, 3/4, 5/6, 8/9, 9/10 8PSK 2/5, 13/30, 7/15, 1/2, 8/15, 17/30, 3/5, NovelSats highly efficient encapsulation protocol
19/30, 2/3, 32/45 ,3/4 ,4/5 ,5/6 , 8/9 ,9/10 - Ultra Lightweight Encapsulation (ULE)
16APSK 2/3, 3/4, 4/5, 5/6, 8/9, 9/10 16APSK 2/5, 13/30, 7/15, 1/2, 8/15, 17/30, 3/5, - Generic Stream Encapsulation (GSE)
19/30, 2/3, 32/45, 3/4, 4/5, 5/6, 8/9, 9/10 Routing and filtering capabilities:
32APSK 3/4, 4/5, 5/6, 8/9, 9/10 32APSK 2/5, 13/30, 7/15, 1/2, 8/15, 17/30, 3/5, - Unlimited VLAN filters
19/30, 2/3, 32/45, 3/4, 4/5, 5/6, 8/9, 9/10 - Unlimited remotes per carrier
64APSK N/A 64APSK 19/30, 2/3, 32/45, 3/4, 4/5, 5/6, 8/9, 9/10 - One NPA/MAC per remote
Frame length 16200, 64800 Frame length 16200, 64800 Bridge mode (Layer 2)/Router mode (Layer 3)
ROF SRRC 20%, 25% ,35% ROF SRRC Like 5%, 10%, 15%, 20%, 25%, 35% Advanced encryption
IF-Band IF-Band
Connector BNC (F) 75 Ohm Connector BNC (F) 75 Ohm
Freq. range 70MHz20MHz, 140MHz40MHz in 10Hz steps Freq. range 70MHz20MHz, 140MHz40MHz in 10Hz steps
Power level -30 to 0dBm Signal level -106+10log(F) (F in MSPS) Max: -20dBm
Power setting 0.1dB Composite power <-20 dBm
resolution Return loss > 10dB
Power accuracy / 0.5dB/0.5dB
temp. stability
Return loss > 12dB
Spurious -55dBc in band and out of band at max power
Additional Information
Monitor and Control Interfaces Physical Environmental
SW interfaces Command line interface Weight 4Kg (8.8 lbs) Prime power 100-240VAC,50-60Hz
Web based graphic user interface Size 19W x 18 D x 1.75 H -48VDC (Option)
SNMP V3 48.3 x 45.7 x 4.45 cm Operating temp. 0 to 50C
Front panel
10MHz Clock Operating humidity Up to 85% Non-Condensing
Serial RS232 Female 9-Pin D-sub connector
Stability 1.0 ppm over 0degC to 50degC (standard) Storage temp. -40C to 70C
Ethernet 10/100 BaseT interface to monitor and 0.03ppm over 0degC to 50degC (option)
control the modem Storage humidity Up to 95% Non-Condensing
Aging 1.0 ppm/year (standard)
Alarm interface Female 9-Pin D-sub connector 0.075 ppm/year (option)