[Operation procedure]
4. Specify "1" to "#0 INIT. SET" for the axis for which zero-point
initialization is to be performed.
5. Specify data for "#2 ZERO".
ORIGIN SET
6. Move the axis to the machine basic position and align it with
the basic point.
7. Specify "1" to "#1 ORIGIN".
8. The machine will move in the direction specified with [ABS.
ORIG-RTN
POSI PARAM] "#2050 absdir".
9. The axis automatically stops at the first grid point.
The basic machine coordinate system is automatically
set.
This sets up the absolute position. OK
10. This completes zero-point initialization.
After completion of zero-point initialization for all axes, turn
power OFF and ON again.
11. Output parameter tape.
To change just the basic machine coordinate zero point, perform steps 4 and 5 above, and then turn the power
OFF and ON.
Start point 6)
9) 8) 7)
Zero point of basic Machine basic
machine coordinate point
Reference point
Grid point
Zero-return parameter
"#2037 G53ofs" (Electrical basic position)
"TO END"
"#2 ZERO" (#2059 zerbas=1)
"#2 ZERO" (#2059 zerbas=0)