Vous êtes sur la page 1sur 2

O4CV

'AL' LED red: Module hardware alarm


This LED is on, if a hardware alarm on the module is detected.
'RDY' LED green: Module ready
On as long as the module is in normal operation mode.
Flashes slowly during hardware alarm.
' ' LED yellow: Module warning
On as long as the module is not in normal operation mode and no module
alarm is present.

SERVICE-PHONE:

'RDY' LED green: Service phone ready


On if the speech channel is available for the service phone.

'ENA' LED green: Service phone enabled


On if the service phone is enabled on the module.
Flashes if the service phone is ringing.

P4LX
LEDs:

'RDY' LED green: System ready


Lights if the ETL600 system is in normal operation.

'P4LX' LED red: Module hardware alarm


Lights if a hardware alarm on P4LX is detected.

'SYS' LED red: Cabinet alarm / System alarm


Lights if a system alarm is present.

'HW' LED red: Hardware alarm


Lights if a hardware alarm on one or more of the
ETL600 modules is detected.

'LNK' LED red: Link Alarm


Lights if the link for either channel is disturbed or for low
receive level.
' ' LED yellow: System warning
Lights if the system is not in normal operation mode
and no system alarm is present.

Data port sockets:

LAN 4 Socket for LAN port 4 (requires SFP)


LAN 3 Socket for LAN port 3
LAN 2 Socket for LAN port 2
LAN 1 Socket for LAN port 1
Digital transit 2 Sockets for Digital transit ports
'HMI' Socket for HMI communication port
(9 pole RS-232 configured as DCE)
'IRIG-B' Socket for IRIG-B input for RTC synchronization
'V.24 PORT 1' Socket for V.24 data port 1
'V.24 PORT 2' Socket for V.24 data port 2
'V.24 PORT 3' Socket for V.24 data port 3
'V.24 PORT 4' Socket for V.24 data port 4
'V.11 PORT 1' Socket for V.11 data port 1
'V.11 PORT 2' Socket for V.11 data port 2

G4AI
'AL' LED red: Module hardware alarm ,

On if a hardware alarm on the module is detected.

'RDY' LED green: Module ready

On as long as the module is in normal operation mode.

' ' LED yellow: Module warning

On as long as the module is not in normal operation

mode and no module alarm is present.

'IN1 ... IN4' LEDs green: Input 1, 2, 3, or 4

On as long as input 1, 2, 3 or 4 is active.

'OUT1 ... OUT4' LEDs green: Output 1, 2, 3 or 4

On as long as solid state output 1, 2, 3 or 4 is active.

'REL1, REL2' LEDs green: Relay 1, Relay 2

On as long as relay output 1 or 2 is active.

'RESET' Push button: Reset

When pressed, the module resets and fetches configuration data from
flash EPROM.