Académique Documents
Professionnel Documents
Culture Documents
1
Second Floor Plan Third Floor Plan
2
2.0 Sectional Perspective
Space A Space B
3
3.0 Daylight Factor Analysis ( Space A - Kids Zone )
Daylight Contour
Total Area of Internal surface (m2) (15.4 + 28.8 + 28.8 + 25.4 + 31.8 + 31.8)
=162
4
Lumen Method :
Calculation:
5
Number of fitting required, N
N = E x A / F x UF x MF
= 400 x 31.8 / (4000 x 0.43 x 0.8)
= 12720/1376
= 9 lamps
Fitting Layout
6
Artificial Lighting Analysis ( Space B - Theatre )
Lumen Method :
Calculation:
Theatre
Total Floor Area (m2) 36
Height of Ceiling (m) 5.65
Type of light fixture LED track light
Lumious flux, (lm) 2000
Height of luminaires, (m) 5.65
Height of working plane (m) 0.8
Mounting Height , Hm (m) 5.65-0.8
=4.85
Standard Illumination required according 200 ( Reading area)
to MS1525
7
Reflectance factor Ceiling (White plastering) : 0.7
Wall (Black painted wall) : 0.1
Working plane (Hardwood) : 0.1
N = E x A / F x UF x MF
= 200 x 36 / (2000 x 0.3 x 0.8)
= 7200/480
= 15 lamps
Fitting Layout