Vous êtes sur la page 1sur 1

4th floor

column calculation
column number grade of concrete M20 and HYSD 415
axial load
P= 69.95 KN
Ma(Hor.)= 12.79 Mb(Ver.)= 5.33 KN.m
Length of column= 3.3 m effective length of column= 2.145 m
Column dim.= 0.4 0.25
b(m) d(m)
le/D= 8.58 < 12 short column (cl.-25.1.2) check

ea= 182.844889 mm eb= 76.19728 mm check


Minimum eccentricities(Cl.-25.4)
ea min= 19.9333333 mm eb min.= 14.93333 mm
eccentricity classification:-
100 <ea,eb< 600 check
combined compression and bending-case3
Mpa(table
cbc= 7 21)
cc= 5 Mpa
m(modular ratio)= 13.33333333
Taking the minimum reinforcement(code value 0.8% Gross area)(Cl.26.5.3.1)
take reinforcement= 2 %
Asc= 2000 mm2
effective cover= 0.04 m
Ae= 124666.667 mm2
Iea= 526013333 mm2 Ieb= 1342213333 mm2

direct stress,cc'=P/Ae= 0.561096257 N/mm2
Bending stress due to Ma is (cbc)'a=(Ma*D/2Ia)= 3.03937163 N/mm2
Bending stress due to Mb is (cbc)'b=(Mb*D/2Ia)= 1.26660287 N/mm2
total bending stress= ((cbc)'a+(cbc)'b)= 4.305975 Mpa
design based on un cracked section:-
(cc'/cc)+(cbc'/cbc)= 0.727358 <=1

hence ok

Vous aimerez peut-être aussi