Académique Documents
Professionnel Documents
Culture Documents
ZTE University
Basic concepts
Active Set:
The set of cells connected with UE;
Monitor Set:
The set of cells not within the active set but being monitored
by a UE according to the adjacent node list allocated by
UTRAN.
Detect Set:
The set of cells in neither the active set nor the monitor set.
ZTE UTRAN HO key parameters
Measurement
The RNC sends a measurement control message to UE.
UE should perform measurement as required and report the measurement
result.
Generally, the measured quantity is the common pilot s Ec/No.
Decision
The RNC stores data of different cells according to the measurement
results.
The RNC makes preliminary decision according to the event decision
method.
e.g.
When the event is reported and the target cell is acceptable, send an
active set update command to add/delete the cell into/from the active set.
Execution
The RNC sends an active set update command to UE and UE starts
handover.
ZTE UTRAN HO key parameters
Event Description
Key parameters
1.Soft
1. Soft Handover Method
Key parameters
Key parameters
Default value 2
The location
information in RNC Radio Resource Management
OMC-R
Reference
information No data
ZTE UTRAN HO key parameters
Key parameters
1.Time
1. Time to Trigger(for 1a/1b/1c/1d/1e/1f/1j)
Parameter name Time to Trigger(for 1a/1b/1c/1e/1f/1j)
It indicates the period of time during which the event
Paticular information
condition has to be satisfied, used for event
of parameter
1a/1b/1c/1e/1f.
(0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320,
The range of value
640, 1280, 2560, 5000)ms
Multi configuration as follows
[1a 1b 1c 1d 1e 1f 1j]
UTRAN Event Report Parameters For CPICH Ec/No:
[320 640 320 320 200 200 320]ms
UE Event Report Parameters For CPICH Ec/No:
Default value
[320 640 320 320 200 200 320]ms
UTRAN Event Report Parameters For CPICH RSCP:
[200 200 200 200 200 200 200]ms
UE Event Report Parameters For CPICH RSCP:
[200 200 200 200 200 200 200]ms
The location
RNC Radio Resource Management
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters
Key parameters
1.Hysteresis
1.Hysteresis
Hysteresis
Parameter name
It indicates the offset when the event condition has
Paticular information of been satisfied, used for event 1a/1b/1c/1d/1e/1f.
parameter When this value increases, it harder to process those
events; and vice verce.
The range of value (0..7.5)dB step 0.5dB
Multi configuration as follows
[1a 1b 1c 1d 1e 1f 1j]
UTRAN Event Report Parameters For CPICH Ec/No:
[0 0 4 4 2 2 4]dB
UE Event Report Parameters For CPICH Ec/No:
Default value [0 0 4 4 2 2 4]dB
UTRAN Event Report Parameters For CPICH RSCP:
[4 4 6 6 4 4 6]dB
UE Event Report Parameters For CPICH RSCP:
[4 4 6 6 4 4 6] dB
The location RNC Radio Resource Management
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters
Event Description
Key parameters
Key parameters
1. Absolute Threshold for 2b/2d/2f with Carrier Frequency Threshold
1.Absolute
used frequency
Parameter Absolute Threshold for 2b/2d/2f with Carrier FrequencyThreshold used frequency
name
Paticular
information of It indicates the absolute threshold of event 2b/2d/2f for used frequency.
parameter
The range of CPICH RSCP: (-115..-25 )dBm
value CPICH Ec/No: (-24..0) dB
Mutli configuration as follows:
[2b 2d 2f]
UTRAN Inter-Freq Event Measurement Cofiguration Number For CPICH EcN0: [-13
-6 -5 ]dB
UE Intra-Freq Event Measurement Cofiguration Number For CPICH EcN0:
[-13 -13 -5]dB
UE Inter-Freq Event Measurement Cofiguration Number For CPICH EcN0:
Default value [-13 -13 -5]dB
UTRAN Inter-Freq Event Measurement Cofiguration Number For RSCP UE:
[-95 -95 -70]dBm
Intra-Freq Event Measurement Cofiguration Number For RSCP:
[-95 -95 -70]dBm
UE Inter-Freq Event Measurement Cofiguration Number For RSCP:
[-95 -95 -70]dBm
The location
information in RNC Radio Resource Management
OMC-R
Reference No data
information
ZTE UTRAN HO key parameters
Key parameters
Hysteresis
1.Hysteresis
1.
Parameter name Hysteresis
Paticular information It indicates the offset when the event condition has been satisfied,
of parameter used for event 2a/2b/ 2c/2d/ 2e/2f.
The range of value (0, 0.5..14.5)dB step 0.5dB
Mutli configuration as follows
[2a 2b 2c 2d 2e 2f]
UTRAN Inter-Freq Event Measurement Cofiguration Number For
CPICH EcN0: [6 4 4 1 4 1]dB
UE Intra-Freq Event Measurement Cofiguration Number For
CPICH EcN0:
[4 4 4 4 4 4 ]dB
UE Inter-Freq Event Measurement Cofiguration Number For
CPICH EcN0:
Default value [4 4 4 4 4 4 ]dB
UTRAN Inter-Freq Event Measurement Cofiguration Number For
RSCP UE:
[4 4 4 4 4 4 ]dB
Intra-Freq Event Measurement Cofiguration Number For RSCP:
[4 4 4 4 4 4 ]dB
UE Inter-Freq Event Measurement Cofiguration Number For
RSCP:
[4 4 4 4 4 4 ]dB
The location RNC Radio Resource Management
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters
Key parameters
1.Time to Trigger
1.Time
Inter-RAT HO
Event Description
Key parameters
Key parameters
Key parameters
1.Other
1. Other RAT Absolute Threshold for 3a/3b/3c
Parameter name Other RAT Absolute Threshold for 3a/3b/3c
Paticular
In event 3a/3b/3c, it indicates the absolute threshold for other
information of
system
parameter
The range of CPICH RSCP: (-115..-25 )dBm
value CPICH Ec/No: (-24..0) dB
Mutli configureation as follows
[3a 3b 3c]
UTRAN Event Report Parameters For Own System CPICH
Ec/No:
[-90 -95 -95]dBm
UE Event Report Parameters For Own System CPICH Ec/No:
Default value
[-90 -95 -95]dBm
UTRAN Event Report Parameters For Own System CPICH
RSCP:
[-90 -95 -95]dBm
UE Event Report Parameters For Own System CPICH RSCP:
[-90 -95 -95]dBm
The location
information in RNC Radio Resource Management
OMC-R
Reference
No data
information
ZTE UTRAN HO key parameters
Key parameters
Hysteresis
1.Hysteresis
1.
Hysteresis
Parameter name
Paticular information
It indicates the offset when the event condition has been satisfied.
of parameter
The range of value (0, 0.5..14.5)dB step 0.5dB
Default value Mutli configureation as follows
[3a 3b 3c 3d]
UTRAN Event Report Parameters For Own System CPICH Ec/No:
[4 4 2 4]dB
UE Event Report Parameters For Own System CPICH Ec/No:
[4 4 2 4]dB
UTRAN Event Report Parameters For Own System CPICH
RSCP:
[4 4 4 4]dB
UE Event Report Parameters For Own System CPICH RSCP:
[4 4 4 4]dB
The location
RNC Radio Resource Management
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters
Key parameters
1.Time to Trigger
1.Time
Cell-reselection
Cell-reselection
Rs = Qmeas,s + Qhysts
Ln = 0 if HCS_PRIOn = HCS_PRIOs
Ln = 1 if HCS_PRIOn <> HCS_PRIOs
Key parameters
Key parameters
1.Qqualmin
1.Qqualmin
Key parameters
Qrxlevmin
1.Qrxlevmin
1.
Key parameters
1.Qhyst1s
1.Qhyst1
Parameter name Qhyst1s
Paticular This parameter specifies the hysteresis
information of value (Qhyst). It is used for FDD cells in
parameter case the quality measure for cell
selection and re-selection is set to
CPICH RSCP.
The range of value (0..40)dB Step2dB
Default value 2dB
The location
information in OMC- Cell Selection and Reselection
R
Reference
No data
information
ZTE UTRAN re-selection key parameters
Key parameters
1.Qhyst2s
1.Qhyst2
Key parameters
Key parameters
Key parameters
1.Temporary_offset1 in SIB11
1.Temporary_offset1
Parameter
Temporary_offset1 in SIB11
name
This specifies the offset applied to the H and R
Paticular criteria for a neighbouring cell for the duration of
information of PENALTY_TIMEn. It is used for TDD and GSM cells
parameter and for FDD cells in case the quality measure for cell
selection and re-selection is set to CPICH RSCP.
The range of
(3, 6, 9, 12, 15, 18, 21, inf) dB
value
Default value 9dB
The location
information in Neighbouring Cell
OMC-R
Reference
No data
information
ZTE UTRAN re-selection key parameters
Key parameters
1.Temporary_offset2
1. Temporary_offset2 in SIB11
Key parameters
Key parameters
1.Temporary_offset2 in SIB12
1.Temporary_offset2
Temporary_offset2 in SIB12
Parameter name
This specifies the offset applied to the H and R criteria for
Paticular information a neighbouring cell for the duration of PENALTY_TIME n.
of parameter It is used for FDD cells in case the quality measure for cell
selection and re-selection is set to CPICH Ec/No.
The range of value (2, 3, 4, 6, 8, 10, 12, inf)dB
Default value 10 dB
The location
Neighbouring Cell
information in OMC-R
Reference information No data
Content
Key parameters
P-CPICH Power
Parameter name
Paticular
information of The power of primary CPICH channel
parameter
The range of
(-10.0..50.0)dBm,step 0.1dBm
value
Default value 33dBm
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters
Key parameters
Key parameters
Key parameters
Key parameters
1.PICH Power
1.PICH
PICH Power
Parameter name
Paticular information
The power of PICH channel
of parameter
The range of value (-10..+5) dB,step 1 dB
Default value -7dB
The location
UtranCell
information in OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters
Key parameters
1.AICH Power
1.AICH
Key parameters
Key parameters
Key parameters
Key parameters
Key parameters
Key parameters
1.T3212
1.T3212
T3212
Parameter name
Paticular The T3212 is representation of the timeout
information of value for periodic location area updating in
parameter decihours.
The range of (0,0.1..25.5)hours Step0.1hour
value 0: No Periodic Updating
Default value 3hour
The location
information in RNC Radio Resource Management
OMC-R
Reference
No data
information
ZTE UTRAN other key parameters
Key parameters
RACH procedure
UE decodes BCH to find out the available RACH sub-channels and their
scrambling codes and signatures
It selects randomly one of the available sub-channels and signatures
The downlink power is measured and the initial RACH power level is set with a
proper margin due to open loop inaccuracy
UE transmits 1 ms long preamble with the selected signature
Node B replies by repeating the preamble using Acquisition Indication Channel
(AICH)
UE decodes AICH message to see whether the NodeB has detected the
preamble
If AICH is not detected, the preamble is resend with 1 dB higher transmit power
If AICH is detected, a 10 or 20 ms long message part is transmitted with the same
power as the last preamble
ZTE UTRAN other key parameters
RACH procedure
ZTE UTRAN other key parameters
Key parameters
Key parameters
1.PRACH
1. PRACH Preamble Power Ramp Step
Key parameters
Paging
ZTE UTRAN other key parameters
Paging
ZTE UTRAN other key parameters
Key parameters
Key parameters
1.UTRAN DRX cycle length coefficient
1.UTRAN
Parameter name UTRAN DRX cycle length coefficient
In order to reduce power loss, UE in the Idle, Cell_Pch, Ura_Pch
state will use discontinuous receiving method, the parameter is a
constant used to calculate the paging occasion. Discontinuous
receiving cycle 2k frame.
If UE is in the Idle state and has carried out Attach process in the
CS domain and PS domain, will select Min(CS domain DRX cycle
Paticular information of length coefficient, PS domain DRX cycle length coefficient) to
parameter calculate the paging occasion . If UE only has carried out Attach
process in one domain ,it will choice the attached CN domain
specific DRX cycle length coefficient to calculate the paging
occasion
If UE in the Connected mode, the UE will choose Min(UTRAN DRX
cycle length coefficient ,the attached CN domain specific DRX
cycle length coefficient) to calculate the paging occasion.
The range of value 3...9
Default value 6
The location
UtranCell
information in OMC-R
Reference information No data