Vous êtes sur la page 1sur 62

ZTE URTAN Parameters introduction

ZTE University

TD&W&PCS BSS Course Team


Objectives

At the end of this course, you will be able to:


Know the ZTE UTRAN features and functions
Master the key parameters of ZTE UTRAN
Content

ZTE UTRAN HO key parameters


ZTE UTRAN re-selection key
parameters
ZTE UTRAN PC key parameters
ZTE UTRAN other key parameters
ZTE UTRAN HO key parameters

Basic concepts

Active Set:
The set of cells connected with UE;

User information is transmitted from these cells.

Monitor Set:
The set of cells not within the active set but being monitored
by a UE according to the adjacent node list allocated by
UTRAN.

Detect Set:
The set of cells in neither the active set nor the monitor set.
ZTE UTRAN HO key parameters

Soft handover process

Measurement
The RNC sends a measurement control message to UE.
UE should perform measurement as required and report the measurement
result.
Generally, the measured quantity is the common pilot s Ec/No.
Decision
The RNC stores data of different cells according to the measurement
results.
The RNC makes preliminary decision according to the event decision
method.
e.g.
When the event is reported and the target cell is acceptable, send an
active set update command to add/delete the cell into/from the active set.
Execution
The RNC sends an active set update command to UE and UE starts
handover.
ZTE UTRAN HO key parameters

Soft handover event

Event Description

Quality of target cell improves, entering a


1A report range of relatively activating set
quality
Quality of target cell decreases, depart from
1B a report range of relatively activating set
quality
The quality of a non-activated set cell is
1C
better than that of a certain activated set cell

1D Best cell generates change


Quality of target cell improves, better than
1E
an absolute threshold
Quality of target cell decreases, worse than
1F
an absolute threshold
ZTE UTRAN HO key parameters

Example of soft handover


ZTE UTRAN HO key parameters

Key parameters

1.Soft
1. Soft Handover Method

Soft Handover Method


Parameter name
Paticular information of
Soft Handover Method
parameter
The range of value Periodical method
Event method
Default value Event method
The location
UtranCell
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters

Key parameters

1.Reporting Range Constant for Event 1A/1B


1.Reporting
Reporting Range Constant for Event 1A/1B
Parameter name
This parameter controls the triggering of event 1A/1B. 1A is
Paticular information of easier but 1B is harder to trigger when this value increases; and
parameter vice verse.

The range of value (0..14.5)dB step 0.5dB


Multi configuration as follows
[1A 1B]
UTRAN Event Report Parameters For CPICH Ec/No:
[3 5]dB
UE Event Report Parameters For CPICH Ec/No:
[3 5]dB
Inter-Frequence Measearment Parameters For CPICH Ec/No:
Default value [3 5]dB
UTRAN Event Report Parameters For CPICH RSCP:
[6 8]dB
UE Event Report Parameters For CPICH RSCP:
[6 8]dB
Inter-Frequence Measearment Parameters For CPICH RSCP:
[6 8]dB
The location RNC Radio Resource Management
information in OMC-R

Reference information No data


ZTE UTRAN HO key parameters

Key parameters

1.Reporting deactivation threshold for Event 1A


1.Reporting

Parameter name Reporting deactivation threshold for Event 1A

Paticular In event 1a,it indicates the maximum number of


information of cells allowed in the active set in order for event 1a
parameter to occur.
The range of
value 0, 1, 2, 3, 4, 5, 6, 7

Default value 2
The location
information in RNC Radio Resource Management
OMC-R

Reference
information No data
ZTE UTRAN HO key parameters

Key parameters

1.Time
1. Time to Trigger(for 1a/1b/1c/1d/1e/1f/1j)
Parameter name Time to Trigger(for 1a/1b/1c/1e/1f/1j)
It indicates the period of time during which the event
Paticular information
condition has to be satisfied, used for event
of parameter
1a/1b/1c/1e/1f.
(0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320,
The range of value
640, 1280, 2560, 5000)ms
Multi configuration as follows
[1a 1b 1c 1d 1e 1f 1j]
UTRAN Event Report Parameters For CPICH Ec/No:
[320 640 320 320 200 200 320]ms
UE Event Report Parameters For CPICH Ec/No:
Default value
[320 640 320 320 200 200 320]ms
UTRAN Event Report Parameters For CPICH RSCP:
[200 200 200 200 200 200 200]ms
UE Event Report Parameters For CPICH RSCP:
[200 200 200 200 200 200 200]ms
The location
RNC Radio Resource Management
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters

Key parameters

1.Hysteresis
1.Hysteresis

Hysteresis
Parameter name
It indicates the offset when the event condition has
Paticular information of been satisfied, used for event 1a/1b/1c/1d/1e/1f.
parameter When this value increases, it harder to process those
events; and vice verce.
The range of value (0..7.5)dB step 0.5dB
Multi configuration as follows
[1a 1b 1c 1d 1e 1f 1j]
UTRAN Event Report Parameters For CPICH Ec/No:
[0 0 4 4 2 2 4]dB
UE Event Report Parameters For CPICH Ec/No:
Default value [0 0 4 4 2 2 4]dB
UTRAN Event Report Parameters For CPICH RSCP:
[4 4 6 6 4 4 6]dB
UE Event Report Parameters For CPICH RSCP:
[4 4 6 6 4 4 6] dB
The location RNC Radio Resource Management
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters

Hard handover event

Event Description

2A Change of best frequency


The estimated quality of a non-used frequency is
above a certain threshold & the estimated quality of
2B
the currently used frequency is below a certain
threshold
The estimated quality of a non-used frequency is
2C
above a certain threshold
The estimated quality of the currently used
2D
frequency is below a certain threshold
The estimated quality of a non-used frequency is
2E
below a certain threshold
The estimated quality of the currently used
2F
frequency is above a certain threshold
ZTE UTRAN HO key parameters

Key parameters

1.Inter- frequence Handover Tactic


1.Inter-

Parameter name Inter- frequence Handover Tactic


Paticular
information of Inter- frequence Handover Tactic
parameter
Algorithm Deciding
The range of 2A Event Trigger
value 2B Event Trigger
2C Event Trigger
Default value 2A
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN HO key parameters

Key parameters
1. Absolute Threshold for 2b/2d/2f with Carrier Frequency Threshold
1.Absolute
used frequency
Parameter Absolute Threshold for 2b/2d/2f with Carrier FrequencyThreshold used frequency
name
Paticular
information of It indicates the absolute threshold of event 2b/2d/2f for used frequency.
parameter
The range of CPICH RSCP: (-115..-25 )dBm
value CPICH Ec/No: (-24..0) dB
Mutli configuration as follows:
[2b 2d 2f]
UTRAN Inter-Freq Event Measurement Cofiguration Number For CPICH EcN0: [-13
-6 -5 ]dB
UE Intra-Freq Event Measurement Cofiguration Number For CPICH EcN0:
[-13 -13 -5]dB
UE Inter-Freq Event Measurement Cofiguration Number For CPICH EcN0:
Default value [-13 -13 -5]dB
UTRAN Inter-Freq Event Measurement Cofiguration Number For RSCP UE:
[-95 -95 -70]dBm
Intra-Freq Event Measurement Cofiguration Number For RSCP:
[-95 -95 -70]dBm
UE Inter-Freq Event Measurement Cofiguration Number For RSCP:
[-95 -95 -70]dBm
The location
information in RNC Radio Resource Management
OMC-R
Reference No data
information
ZTE UTRAN HO key parameters

Key parameters

Hysteresis
1.Hysteresis
1.
Parameter name Hysteresis
Paticular information It indicates the offset when the event condition has been satisfied,
of parameter used for event 2a/2b/ 2c/2d/ 2e/2f.
The range of value (0, 0.5..14.5)dB step 0.5dB
Mutli configuration as follows
[2a 2b 2c 2d 2e 2f]
UTRAN Inter-Freq Event Measurement Cofiguration Number For
CPICH EcN0: [6 4 4 1 4 1]dB
UE Intra-Freq Event Measurement Cofiguration Number For
CPICH EcN0:
[4 4 4 4 4 4 ]dB
UE Inter-Freq Event Measurement Cofiguration Number For
CPICH EcN0:
Default value [4 4 4 4 4 4 ]dB
UTRAN Inter-Freq Event Measurement Cofiguration Number For
RSCP UE:
[4 4 4 4 4 4 ]dB
Intra-Freq Event Measurement Cofiguration Number For RSCP:
[4 4 4 4 4 4 ]dB
UE Inter-Freq Event Measurement Cofiguration Number For
RSCP:
[4 4 4 4 4 4 ]dB
The location RNC Radio Resource Management
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters

Key parameters
1.Time to Trigger
1.Time

Parameter name Time to Trigger


Paticular It indicates the period of time during which the event condition has to be
information of satisfied.
parameter
The range of (0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,
value 5000)ms
Mutli configuration as follows
[2a 2b 2c 2d 2e 2f]
UTRAN Inter-Freq Event Measurement Cofiguration Number For CPICH
EcN0: [100 100 100 640 100 640]ms
UE Intra-Freq Event Measurement Cofiguration Number For CPICH EcN0:
[100 100 100 640 100 640]ms
UE Inter-Freq Event Measurement Cofiguration Number For CPICH EcN0:
Default value [100 100 100 640 100 640]ms
UTRAN Inter-Freq Event Measurement Cofiguration Number For RSCP
UE:
[100 100 100 640 100 640]ms
Intra-Freq Event Measurement Cofiguration Number For RSCP:
[100 100 100 640 100 640]ms
UE Inter-Freq Event Measurement Cofiguration Number For RSCP:
[100 100 100 640 100 640]ms
The location
information in RNC Radio Resource Management
OMC-R
Reference No data
information
ZTE UTRAN HO key parameters

Inter-RAT HO

Event Description

the quality of the UTRAN carrier currently


in use is lower than while the assessed
3A
quality of other systems is higher than the
predefined threshold
The estimated quality of other system is
3B
below a certain threshold

The estimated quality of other system is


3C
above a certain threshold

3D The best cell of other system update


ZTE UTRAN HO key parameters

Key parameters

1.Inter-Rat Handover Tactic


1.Inter-Rat

Inter-Rat Handover Tactic


Parameter name
Paticular
information of Inter-Rat Handover Tactic
parameter
The range of Algorithm Deciding
value 3A Event Trigger
3C Event Trigger
Default value 3A Event Trigger
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN HO key parameters

Key parameters

1.UTRAN Absolute Threshold for 3a


1.UTRAN
Parameter name UTRAN Absolute Threshold for 3a
Paticular information In event 3a, it indicates the absolute threshold for
of parameter UTRAN own system.
The range of value CPICH RSCP: (-115..-25 )dBm
CPICH Ec/No: (-24..0) dB
Default value Mutli configureation as follows
UTRAN Event Report Parameters For Own System
CPICH Ec/No: -6dB
UE Event Report Parameters For Own System
CPICH Ec/No:-6dB
UTRAN Event Report Parameters For Own System
CPICH RSCP:-95dBm
UE Event Report Parameters For Own System
CPICH RSCP:-95dBm
The location
RNC Radio Resource Management
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters

Key parameters

1.Other
1. Other RAT Absolute Threshold for 3a/3b/3c
Parameter name Other RAT Absolute Threshold for 3a/3b/3c
Paticular
In event 3a/3b/3c, it indicates the absolute threshold for other
information of
system
parameter
The range of CPICH RSCP: (-115..-25 )dBm
value CPICH Ec/No: (-24..0) dB
Mutli configureation as follows
[3a 3b 3c]
UTRAN Event Report Parameters For Own System CPICH
Ec/No:
[-90 -95 -95]dBm
UE Event Report Parameters For Own System CPICH Ec/No:
Default value
[-90 -95 -95]dBm
UTRAN Event Report Parameters For Own System CPICH
RSCP:
[-90 -95 -95]dBm
UE Event Report Parameters For Own System CPICH RSCP:
[-90 -95 -95]dBm
The location
information in RNC Radio Resource Management
OMC-R
Reference
No data
information
ZTE UTRAN HO key parameters

Key parameters

Hysteresis
1.Hysteresis
1.

Hysteresis
Parameter name
Paticular information
It indicates the offset when the event condition has been satisfied.
of parameter
The range of value (0, 0.5..14.5)dB step 0.5dB
Default value Mutli configureation as follows
[3a 3b 3c 3d]
UTRAN Event Report Parameters For Own System CPICH Ec/No:
[4 4 2 4]dB
UE Event Report Parameters For Own System CPICH Ec/No:
[4 4 2 4]dB
UTRAN Event Report Parameters For Own System CPICH
RSCP:
[4 4 4 4]dB
UE Event Report Parameters For Own System CPICH RSCP:
[4 4 4 4]dB
The location
RNC Radio Resource Management
information in OMC-R
Reference information No data
ZTE UTRAN HO key parameters

Key parameters

1.Time to Trigger
1.Time

Parameter name Time to Trigger


Paticular information It indicates the period of time during which the event condition has to
of parameter be satisfied.
The range of value (0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,
5000)ms
Default value Mutli configureation as follows
[3a 3b 3c 3d]
UTRAN Event Report Parameters For Own System CPICH Ec/No:
[100 100 100 100]ms
UE Event Report Parameters For Own System CPICH Ec/No:
[100 100 100 100]ms
UTRAN Event Report Parameters For Own System CPICH RSCP:
[100 100 100 100]ms
UE Event Report Parameters For Own System CPICH RSCP:
[100 100 100 100]ms
The location
RNC Radio Resource Management
information in OMC-R
Reference information No data
Content

ZTE UTRAN HO key parameters


ZTE UTRAN re-selection key
parameters
ZTE UTRAN PC key parameters
ZTE UTRAN other key parameters
ZTE UTRAN re-selection key parameters

Cell-reselection

for FDD cells: Srxlev > 0 AND Squal > 0

for TDD cells: Srxlev > 0

Squal = Qqualmeas Qqualmin

Srxlev = Qrxlevmeas - Qrxlevmin - Pcompensation

Pcompensation = max(UE_TXPWR_MAX_RACH P_MAX, 0)


ZTE UTRAN re-selection key parameters

Cell-reselection

Rs = Qmeas,s + Qhysts

Rn = Qmeas,n - Qoffsets,n - TOn * (1 Ln)

TOn = TEMP_OFFSETn * W(PENALTY_TIMEn Tn)

Ln = 0 if HCS_PRIOn = HCS_PRIOs
Ln = 1 if HCS_PRIOn <> HCS_PRIOs

W(x) = 0 for x < 0


W(x) = 1 for x >= 0
ZTE UTRAN re-selection key parameters

Key parameters

1.Cell selection and reselection quality measure


1.Cell

Parameter name Cell selection and reselection quality measure


Paticular
The measurement quantity for cell selection
information of
and reselection.
parameter
The range of CPICH Ec/N0
value CPICH RSCP
Default value CPICH Ec/N0
The location
information in Cell Selection and Reselection
OMC-R
Reference
No data
information
ZTE UTRAN re-selection key parameters

Key parameters

1.Qqualmin
1.Qqualmin

Parameter name Qqualmin


Paticular information This parameter indicates minimum
of parameter required quality level in the cell.
The range of value (-24..0)dB
Default value -18dB
The location
Cell Selection and Reselection
information in OMC-R
Reference
No data
information
ZTE UTRAN re-selection key parameters

Key parameters

Qrxlevmin
1.Qrxlevmin
1.

Parameter name Qrxlevmin


Paticular
This parameter indicates minimum
information of
required RX level in the cell.
parameter
The range of
(-115..-25)dBm Step2dBm
value
Default value -111dBm
The location
information in Cell Selection and Reselection
OMC-R
Reference
No data
information
ZTE UTRAN re-selection key parameters

Key parameters

1.Qhyst1s
1.Qhyst1
Parameter name Qhyst1s
Paticular This parameter specifies the hysteresis
information of value (Qhyst). It is used for FDD cells in
parameter case the quality measure for cell
selection and re-selection is set to
CPICH RSCP.
The range of value (0..40)dB Step2dB
Default value 2dB
The location
information in OMC- Cell Selection and Reselection
R
Reference
No data
information
ZTE UTRAN re-selection key parameters

Key parameters

1.Qhyst2s
1.Qhyst2

Parameter name Qhyst2s


Paticular information This parameter specifies the hysteresis
of parameter value (Qhyst). It is used for FDD cells if
the quality measure for cell selection
and re-selection is set to CPICH Ec/No.
The range of value (0..40)dB Step2dB
Default value 2dB
The location
information in OMC- Cell Selection and Reselection
R
Reference
No data
information
ZTE UTRAN re-selection key parameters

Key parameters

1.Cell individual offset


1.Cell

Parameter name Cell individual offset


Paticular information Cell individual offset used to calculate
of parameter the cell quality
UtranCell:(-10..10)dB step 0.5 dB;
The range of value
GsmCell: (-50..50) dB step 1 dB
Default value 0dB
The location UtranCell; External Utran Cell; External
information in OMC-R Gsm Cell
Reference information No data
ZTE UTRAN re-selection key parameters

Key parameters

1.penalty time in SIB11


1.penalty

penalty time in SIB11


Parameter name
This specifies the time duration for
Paticular information of
which the TEMPORARY_OFFSETn is
parameter
applied for a neighbouring cell.
The range of value (Not Used,10, 20, 30, 40, 50, 60 )s
Default value 10s
The location Neighbouring Cell, Gsm Neighbouring
information in OMC-R Cell
Reference information No data
ZTE UTRAN re-selection key parameters

Key parameters

1.Temporary_offset1 in SIB11
1.Temporary_offset1

Parameter
Temporary_offset1 in SIB11
name
This specifies the offset applied to the H and R
Paticular criteria for a neighbouring cell for the duration of
information of PENALTY_TIMEn. It is used for TDD and GSM cells
parameter and for FDD cells in case the quality measure for cell
selection and re-selection is set to CPICH RSCP.
The range of
(3, 6, 9, 12, 15, 18, 21, inf) dB
value
Default value 9dB
The location
information in Neighbouring Cell
OMC-R
Reference
No data
information
ZTE UTRAN re-selection key parameters

Key parameters

1.Temporary_offset2
1. Temporary_offset2 in SIB11

Parameter name Temporary_offset2 in SIB11


This specifies the offset applied to the H and R criteria
for a neighbouring cell for the duration of
Paticular information
PENALTY_TIMEn. It is used for FDD cells in case the
of parameter
quality measure for cell selection and re-selection is set
to CPICH Ec/No.
The range of value (2, 3, 4, 6, 8, 10, 12, inf)dB
Default value 10 dB
The location
Neighbouring Cell
information in OMC-R
Reference
No data
information
ZTE UTRAN re-selection key parameters

Key parameters

1.penalty time in SIB12


1.penalty

Parameter name penalty time in SIB12


This specifies the time duration for which
Paticular information of
the TEMPORARY_OFFSET n is applied for
parameter
a neighbouring cell.
The range of value (Not Used,10, 20, 30, 40, 50, 60 )s
Default value 10s
The location Neighbouring Cell, Gsm Neighbouring
information in OMC-R Cell
Reference information No data
ZTE UTRAN re-selection key parameters

Key parameters

1.Temporary_offset2 in SIB12
1.Temporary_offset2

Temporary_offset2 in SIB12
Parameter name
This specifies the offset applied to the H and R criteria for
Paticular information a neighbouring cell for the duration of PENALTY_TIME n.
of parameter It is used for FDD cells in case the quality measure for cell
selection and re-selection is set to CPICH Ec/No.
The range of value (2, 3, 4, 6, 8, 10, 12, inf)dB
Default value 10 dB
The location
Neighbouring Cell
information in OMC-R
Reference information No data
Content

ZTE UTRAN HO key parameters


ZTE UTRAN re-selection key
parameters
ZTE UTRAN PC key parameters
ZTE UTRAN other key parameters
ZTE UTRAN PC key parameters

Key parameters

1.Primary CPICH Power


1.Primary

P-CPICH Power
Parameter name
Paticular
information of The power of primary CPICH channel
parameter
The range of
(-10.0..50.0)dBm,step 0.1dBm
value
Default value 33dBm
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters

Key parameters

1.Primary SCH Power


1.Primary

Primary SCH Power


Parameter name
Paticular
information of The power of primary SCH channel
parameter
The range of
(-35..+15) dB step 0.1dB
value
Default value -3dB
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters

Key parameters

1.Secondary SCH Power


1.Secondary

Parameter name Secondary SCH Power


Paticular information
The power of second SCH channel
of parameter
The range of value (-35..+15) dB Step0.1dB
Default value -4dB
The location
UtranCell
information in OMC-R
Reference information No data
ZTE UTRAN PC key parameters

Key parameters

1.Max FACH Power


1.Max

Parameter name Max FACH Power


Paticular
The max FACH power,which beared on
information of
sccpch.
parameter
The range of value (-35..15)dB step 0.1 dB
Default value -1dB
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters

Key parameters

1.PICH Power
1.PICH

PICH Power
Parameter name
Paticular information
The power of PICH channel
of parameter
The range of value (-10..+5) dB,step 1 dB
Default value -7dB
The location
UtranCell
information in OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters

Key parameters

1.AICH Power
1.AICH

Parameter name AICH Power


Paticular
information of The power of AICH channel
parameter
The range of
(-22..5)dB,step 1
value
Default value 7dB
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters

Key parameters

1.Maximum allowed UL Power


1.Maximum

Parameter name The maximum uplink power of the DPCH


Paticular
information of The maximum uplink power of the DPCH
parameter
The range of value (-50..33)dBm step 1
Default value 33dBm
The location
information in RNC Radio Resource Management
OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters

Key parameters

1.TPC uplink step size


1.TPC

Parameter name TPC step size


Paticular
information of TPC step size for the uplink
parameter
The range of value (1,2)dB
Default value 1dB
The location
information in RNC Radio Resource Management
OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters

Key parameters

1.TPC DL Step Size


1.TPC

Parameter name TPC DL Step Size


Paticular
information of TPC step size for the downlink
parameter
The range of value (0.5, 1, 1.5, 2)dB
Default value 1dB
The location
information in RNC Radio Resource Management
OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters

Key parameters

1.Uplink SIRtarget Up Step


1.Uplink

Parameter name UL SIRtarget Up Step


Paticular
information of The step of the SIR target up for uplink
parameter
The range of value (0.1..0.5) dB step 0.1dB
Default value 0.3dB
The location
information in RNC Radio Resource Management
OMC-R
Reference
No data
information
ZTE UTRAN PC key parameters

Key parameters

1.Uplink SIRtarget Down Step


1.Uplink

UL SIRtarget Down Step


Parameter name
Paticular
The step of the SIR target down for
information of
uplink
parameter
The range of
(0.1..0.5) dB step 0.1dB
value
Default value 0.1dB
The location
information in RNC Radio Resource Management
OMC-R
Reference
No data
information
Content

ZTE UTRAN HO key parameters


ZTE UTRAN re-selection key
parameters
ZTE UTRAN PC key parameters
ZTE UTRAN other key parameters
ZTE UTRAN other key parameters

Key parameters

1.T3212
1.T3212

T3212
Parameter name
Paticular The T3212 is representation of the timeout
information of value for periodic location area updating in
parameter decihours.
The range of (0,0.1..25.5)hours Step0.1hour
value 0: No Periodic Updating
Default value 3hour
The location
information in RNC Radio Resource Management
OMC-R
Reference
No data
information
ZTE UTRAN other key parameters

Key parameters

1.IMSI Attach and Detach Indicator


1.IMSI

Parameter name IMSI Attach and Detach Indicator


This parameter indicates whether the
Paticular information
attach and detach procedures are
of parameter
required to be used or not.
MSs shall not apply IMSI attach and
detach procedure;
The range of value
MSs shall apply IMSI attach and detach
procedure
MSs shall apply IMSI attach and detach
Default value
procedure
The location
RNC Radio Resource Management
information in OMC-R
Reference
No data
information
ZTE UTRAN other key parameters

RACH procedure

UE decodes BCH to find out the available RACH sub-channels and their
scrambling codes and signatures
It selects randomly one of the available sub-channels and signatures
The downlink power is measured and the initial RACH power level is set with a
proper margin due to open loop inaccuracy
UE transmits 1 ms long preamble with the selected signature
Node B replies by repeating the preamble using Acquisition Indication Channel
(AICH)
UE decodes AICH message to see whether the NodeB has detected the
preamble
If AICH is not detected, the preamble is resend with 1 dB higher transmit power
If AICH is detected, a 10 or 20 ms long message part is transmitted with the same
power as the last preamble
ZTE UTRAN other key parameters

RACH procedure
ZTE UTRAN other key parameters

Key parameters

1.PRACH Initiation Tx Power Correction value


1.PRACH

PRACH Initiation Tx Power correction


Parameter name
value
Paticular
This parameter is used to calculate the
information of
PRACH preamble initial TX power.
parameter
The range of value (-35..-10)dB
Default value -21dB
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN other key parameters

Key parameters

1.PRACH
1. PRACH Preamble Power Ramp Step

Parameter name PRACH Preamble Power Ramp Step


This parameter specifies the power step
Paticular information
add on PRACH preamble TX power
of parameter
when no ack is received on AICH.
The range of value (1..8)dB
Default value 2dB
The location
UtranCell
information in OMC-R
Reference
No data
information
ZTE UTRAN other key parameters

Key parameters

1.Max number of Preamble Transmitt


1.Max

Parameter name Max number of Preamble Transmitt


Paticular This parameter specifies the max number
information of of preamble retrans before any ACK or
parameter NACK is received.
The range of
1..64
value
Default value 20
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN other key parameters

Paging
ZTE UTRAN other key parameters

Paging
ZTE UTRAN other key parameters

Key parameters

1.Number of Paging Indicators per PICH frame


1.Number

Parameter Number of Paging Indicators per PICH


name frame
Paticular
The number of paging indicators in one
information of
PICH frame.
parameter
The range of
18,36,72,144
value
Default value 18
The location
information in UtranCell
OMC-R
Reference
No data
information
ZTE UTRAN other key parameters

Key parameters
1.UTRAN DRX cycle length coefficient
1.UTRAN
Parameter name UTRAN DRX cycle length coefficient
In order to reduce power loss, UE in the Idle, Cell_Pch, Ura_Pch
state will use discontinuous receiving method, the parameter is a
constant used to calculate the paging occasion. Discontinuous
receiving cycle 2k frame.
If UE is in the Idle state and has carried out Attach process in the
CS domain and PS domain, will select Min(CS domain DRX cycle
Paticular information of length coefficient, PS domain DRX cycle length coefficient) to
parameter calculate the paging occasion . If UE only has carried out Attach
process in one domain ,it will choice the attached CN domain
specific DRX cycle length coefficient to calculate the paging
occasion
If UE in the Connected mode, the UE will choose Min(UTRAN DRX
cycle length coefficient ,the attached CN domain specific DRX
cycle length coefficient) to calculate the paging occasion.
The range of value 3...9
Default value 6
The location
UtranCell
information in OMC-R
Reference information No data

Vous aimerez peut-être aussi