Job No
PROJECT ARTESIA MID RISE BUILDING (G+28) ON PLOT NO.676-5408(E006)
Date 7/26/2017

SUBJECT WIND LOAD Reference BS5399


Wind load Calculation
Wind load is calculated as per BS 6399-Part 2 code of practice for wind loads
Building type Factor Kb = 1 (Ref: Table 1)
Maximum Height of the structure ~ 120 m
Dynamic augmentation factor < 0.1 (Ref:Fig 3)
Building is not dynamic,BS6399-part2 is applicable for this structure and Standard method
is used to calculate wind pressure

Basic wind speed = 45 m/sec


(3-Sec gust wind speed 10m above ground level)
Equivalent hourly mean speed @ open level ground
Appropriate to the geographical conditions Vb = 30 m/sec
Pages from Dubai Wind code is attached for reference
Altitude factor Sa = 1 (Ref: Cl 2.2.2.2)
Direction factor Sd = 1 (Ref: Cl 2.2.2.3)
Seasonal factor Ss = 1 (Ref: Cl 2.2.2.4)
Probability factor Sd = 1 (Ref: Cl 2.2.2.5)
Hence
Site Wind speed Vs = Vb*Sa*Sd*Ss (Ref: Cl 2.2.2)
Site wind Speed Vs = 30 m/sec
Effective height of the structure He = 100 m
Closest distance to sea = 10 kM
Terrain and building factor Sb = 2.12 (Ref: Table 4)

Effective wind Speed Ve = Vs*Sb


= 30*2.12
= 63.6 m/sec
Dynamic wind pressure q = 0.613Ve2 (Ref: Cl 2.1.2)
= 0.613*63.6^2/1000
= 2.5 kN/m2
Sheet

Job No
PROJECT ARTESIA MID RISE BUILDING (G+28) ON PLOT NO.676-5408(E006)
Date 7/26/2017

SUBJECT WIND LOAD Reference BS5399


Wind load Calculation
(I) For Roof X-DIRECTION

B= 22 m A= -2.00
A= b/4 = 5.5 m (B/4) B= -1.40
LENGTH = 2.2 m (B/10) C= -0.70
D= -0.20
UPWARD (Pressure):
ZONE - A = (-2-0.2)*2.5 = 5.50 kN/m2
ZONE - B = (-1.4-0.2)*2.5 = 4.00 kN/m2 COEFFICIENT = +0.2
ZONE - C = (-0.7-0.2)*2.5 = 2.25 kN/m2
ZONE - D = (-0.2-0.2)*2.5 = 1.00 kN/m2
DOWNWARD (Suction):

FOR DOWNWARD, THE ZONE-D IS CONSERVATIVELY


COEFFICIENT = 0.3
CONSIDERED FOR THE WHOLE AREA.
ZONE - D = (-0.2-(0.3))*2.5 = 1.25 kN/m2

(I) For Roof Z-DIRECTION

B= 35 m A= -2.00
A= b/4 = 8.75 m (B/4) B= -1.40
LENGTH = 3.5 m (B/10) C= -0.70
D= -0.20
UPWARD [PRESSURE]:
ZONE - A = (-2-0.2)*2.5 = 5.50 kN/m2
ZONE - B = (-1.4-0.2)*2.5 = 4.00 kN/m2 COEFFICIENT = +0.2
ZONE - C = (-0.7-0.2)*2.5 = 2.25 kN/m2
ZONE - D = (-0.2-0.2)*2.5 = 1.00 kN/m2
DOWNWARD [SUCTION]:

FOR DOWNWARD, THE ZONE-D IS CONSERVATIVELY


COEFFICIENT =0.3
CONSIDERED FOR THE WHOLE AREA.
ZONE - C = (-0.2-(0.3))*2.5 = 1.25 kN/m2
356 28.2011 67
434 24.0311 73.077
435 18.2811 73.077
436 12.5311 73.077
437 1.9811 73.077
488 0.2561 67.35
490 0.2561 67.35
498 0.2561 67.35
895 4.2811 67.15
896 12.3811 67.15
897 27.4761 67.15
898 0.6561 67.15
911 8.3311 67.15
940 16.3811 67.15
941 20.3811 67.15
942 24.3811 67.15
967 27.4761 67.15
968 27.4761 67.15
969 27.4761 67.15
970 0.2561 67.15
972 27.4761 67.15

356 434 435


356 434 435 436 437 488 490 498 895 896 897
11.754
3.651
3.651
3.651
3.651
11.2292
15.7502
23.7502
19.754
19.754
19.754
19.7506
19.754
19.754
19.754
19.754
15.754
7.654
11.654
19.7502
3.602

436 437 488 490 498 895 896 897 898 911
488 490 498 895 896 897 898 911 940 941 942 967 968 969 970 972
940 941 942 967 968 969 970 972