RZR-0916-C

www.daikin.com.my

Authorized dealer:
Head Office: Tel: 03-7953 8388 Fax: 03-7956 4371
Branches: Kedah Tel: 04-730 5670 Johor Tel: 07-557 7788
Penang Tel: 04-331 1670 Pahang Tel: 09-567 6778
Perak Tel: 05-548 2307 Kelantan Tel: 09-747 4578
Negeri Sembilan Tel: 06-768 8969 Sabah Tel: 088-722 194
Melaka Tel: 06-288 1133 Sarawak Tel: 082-333 299
Catalogue No. PCSMY1546 R410A
01 Energy saving COMPACT 02

Throughout the cooling season, CSPF values by capacity for New outdoor units save even more space
Daikins new inverter models cassette models

reduce energy consumption


CSPF 7
Value 97kg
6 6.47
6.19
5.99 Height
Height

15%
Compared with previous non-inverter series, 65kg
15%
5
5.13 5.00 4.85
the new RZR-M series uses about 50% less 4
Down
Down
power consumption. Get quick and effective 3 More
cooling, and cut electricity bills.
2.77 2.79 2.79
compact,
2.69 2.73
2
2.63
1,170
990
mm
1
much higher
mm
0
CSPF!
RZR50 RZR60 RZR71 RZR100 RZR125 RZR140 Weight
Inverter MVM MVM MVM

32kg
MVM MVM MVM
MYM MYM MYM
Non R18 R21 R26 R36 R42 R48
Inverter NUV1 NUV1 NUV1 NUY1 NUY1 NUY1
320 Down
* CSPF (cooling seasonal performance factor) is a new international 900 320 940 mm
mm mm
mm
energy-efficiency criterion calculated by methods stipulated in ISO 16358-1.
RZR140LVVM RZR140MVM
(In case of 14.0kW class)

Comparison of cooling seasonal Compared to the previous mainstream inverter series, outdoor units are much more compact. Easy installation in
places with limited space.
power consumption based on
average CSPF values

100
Cooling seasonal power consumption

50%
reduction!

50

Previous New inverter


non-inverter series RZR-M series
(average) (average)
(cassette type) (cassette type)

New inverter RZR-M series - R410A (cassette type)

Previous non-inverter series - R22 (cassette type)

Note: Value 100 represents the amount of electricity used by a non-inverter model
during a similar annual cooling period.

What is CSPF?
CSPF is the value for the annual total cooling load divided by the annual total power consumption at outdoor air
condition specified by ISO standard.
03 Comfort Benefits of Inverter 04

Faster cooling and dehumidification:

unit price + cost of electricity


New inverter control technology brings quick comfort Non inverter Inverter
Why is inverter technology

Total cost =
economical?
Inverters save more Inverter system consumes less electricity,
Quick cooling start function energy over time and soon recovers the difference in initial
Quickly and easily make space comfortable before the cost. This results in lower total cost.
arrival of office workers or shop customers. As well as Recovery point
Time

quick cooling at max. capacity, new inverter control


rapidly removes indoor humidity. More than simple
temperature reduction, this twin reduction provides
greater comfort (within 30 minutes max.). Inverter air conditioner can adjust its cooling capacity Inverters operate without repeated On/Off operation.
New Inverter (RZR-M series)
according to the cooling load. This results in less
power consumption. Inverter Highway driving
Usual Inverter (RZR-L series) Rated condition
Non inverter BRC1E62 wired remote controller
is used for Quick cooling start.
Non inverter cooling capacity

Capacity ratio
Capacity

Load ratio
1.0 On/Off operation

INV Max Worse efficiency Inverter cooling capacity Continuous driving without stopping and starting is more
fuel efficient.
Non Max
Cooling load Partial load area
Non inverter City driving
Better performance than 0
non-inverter models! Reaches 35
max. capacity faster than Outdoor ambient temperature (C) Stop, go, stop ...
usual inverter models.
In response to fluctuating cooling load , non-inverter air conditioners
repeatedly perform On (full-power)/Off (zero-power) operation. Inverter
Start Time air conditioners, however, operate at optimal cooling capacity
according to the cooling load. Since inverter air conditioners provide
required minimum cooling capacity with minimum electrical power, Constantly stopping and starting consumes energy and is
Indoor total power consumption can be reduced during cooling period. less fuel efficient.
temp.
Reaches the setting
temperature faster.

Start
Why is inverter technology more Inverter
comfortable?
When temperature does not fluctuate much, the set
Setting
temperature is maintained.
temp.
Start Time
Non inverter

Indoor Room Too hot


temperature
humidity
Removes humidity Large
faster. temperature
fluctuation
Start
Set
temperature
Non inverter
Comfortable
Small
temperature
fluctuation
Inverter
Non inverter
Too cold Too cold
Start Time
Time

Inverter control responds to load changes and causes minor temperature adjustments. Non-inverter control frequently turns ON and OFF in
response to load fluctuations or load mismatch and causes large temperature swings.
Durability
05 (RZR-M SERIES) 06

Automatic protection against low Coated printed


voltage circuit boards
More economy or comfort in special situations
In AM and PM peak electricity consumption periods, Coated circuit boards prevent High sensible cooling enables even High dehumidification cooling
supply may fluctuate. Built-in low-voltage protection will problems caused by humidity
automatically cut operations. When normal voltage is and airborne dust. greater power savings provides even greater comfort
restored, operation will resume as before.
Self-diagnosis functions enable
Outdoor unit installation is possible prompt maintenance response
even with limited space An error message appears on the LCD of the remote
controller and an LED lights up on the unit. When the
BRC1E62 is installed, the error code appears showing
contact information and model name. Contact your
Daikin dealer and provide the error code and model
name.

10
0m
mo m o
or In locations such as simple server rooms, In restaurants and other spaces where many people
mmre
re r 0
10 mo dehumidification is not required and greater power gather, High dehumidification cooling mode reduces
10
0m ore
mo m o m
or
m savings are possible with 'High sensible cooling' mode. humidity and creates greater comfort.
re r m
500 *Field setting with remote controller. *Available with RZR100140M models. Field setting on outdoor unit.
07 Convenient functions DESIGN FLEXIBILITY 08

And more... Advanced Daikin inverter technology brings Possible to force OnOff operation using external command
various benefits to owners and installers. (Available in ceiling concealed type and wall mounted type)
*Field setting with remote controller

Demand Control Function * Field setting Off-operation never overlooked if linked to use of hotel keycard:
By setting limits that restrict power * Required for KRP58M51 (Option)
enables overall power savings.
Limitation
consumption, you can cut electricity bills.

consumption
Power
Ceiling Concealed Type Wall Mounted Type
Power consumption is given first priority, and limits FAQ-C series
FBQ-E series
maximum power consumption of unit.
Lighting
8:00 12:00 16:00 20:00 Time
Maximum power consumption can be set at 40, 60, 70,
Interlock
80, or 100%. * RZR100-140 only

Navigation remote controller BRC1E62 includes various convenient functions


Interlock
Automatic return to temperature Owner can preset upper and
preset by owner lower temperatures
Setpoint auto reset Setpoint range set
- Even if the set temperature is - Saves energy by limiting the min.
changed, after a preset period and max. set temperature.
new set temperature returns to - Avoids excessive heating or cooling. * Other type of indoor unit is available by using optional adapter.
preset value. - This function is convenient if the
- Period selectable from 30, 60, 90, remote controller is installed where
or 120 minutes. anyone can change the settings.

Restaurant Example All indoor units comply with D -Net standards (connected to RZR series units)
27C 24C Returns to Previous indoor unit New indoor unit
27C
automatically

Adaptor not
required
Optional
Restaurant opened Full tables at lunchtime After 30 minutes* FHQ-BV interface adaptor
Temperature is set to 27C Then is lowered to 24C Automatically returns to is required FHQ-DA
for crowded room preset temperature (27C)
* Preset-return time can be set at 30, 60, 90, or 120 min

VRV
VRV
Night quiet operation mode
Consideration for people living nearby
Outdoor unit operating sound can be reduced.
Peak outdoor temperature
Capacity (%)

100

8 hours
50 10 hours
Load (%)

0
48
Rated
Sound (dB(A))
Operating

Quiet mode
44 Quiet mode

8:00 12:00 16:00 20:00 0:00 4:00 8:00


Note: Daikin data for RZR71MVM

Operating sound about 4 dB quieter Thanks to easy connection to DIII-NET and long piping length, suitable for projects that include VRV and SkyAir.
09 SMART AIRFLOW CONTROL 10

All indoor units can provide 3-step fine control of air volume
(connected to RZR series units)

Comfort ensured by Auto airflow rate that matches load level


(Available in wall mounted type and ceiling concealed type)

Airflow pattern is selectable to match room shape and installation location


Convenient energy-efficiency for stores with peak and quiet periods. Typical flow patterns There are a total of 23 flow patterns.

Low Medium High Auto L-shaped 2-way flow Opposite 2-way flow You can freely set air discharge
setting by remote controller.

(1) Standard setting

Cassette Cassette
(Round Flow)
(E.g., installed in (E.g., installed in
a corner) a long room)

All-round flow 3-way flow


(2) Ceiling soiling prevention setting

Also convenient for high ceilings and


spaces with long blow distances
(E.g., installed in (E.g., installed
Cassette type <Round Flow>: Ceiling exposed: middle of ceiling) near a wall)
max. 4.2m max. 4.3m 4-way flow also possible.

Long or wide airflow


4.3m
4.2m
Ceiling Exposed

*Field setting with remote controller


11 PRODUCT LINEUP 12

hp*1 1.0 1.5 2.0 2.5 3.0 4.0 5.0 6.0


Capacity
kW *1
25 35 50 60 71 100 125 140

Wall Mounted

FAQ100CVEA

Ceiling Cassette
(4 Way Flow/Round Flow)
Indoor Unit

FFR10CV1 FFR15CV1 FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA

Ceiling Exposed

FLR15EV1L FHQ50DAVMA FHQ60DAVMA FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA


FLR15EV1M

*2 *2 *2 *2 *2 *2

Ceiling Concealed

FDMR10CV1M FDMR15CV1M FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE


Outdoor Unit

RR10DV1 RR15DV1 RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR125MVM RZR140MVM


RZR100MYM RZR125MYM RZR140MYM

Power Source Indoor Indoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor

*1 Capacity (hp) and (kW) are for ease of reference only.


*2 For FBQ-E Series, additional power source at indoor side, please refer to specifications.
13 WALL MOUNTED TYPE 14
Compact & Sophisticated design Design and installation flexibility
Flaps neatly close when not in use 6-direction refrigerant piping
Left pipe
Fresh white colour offers greater installation
flexibility

Back-left pipe
Bottom-left pipe
FAQ100C Right pipe
Back-right pipe
Bottom-right pipe

Maintenance possible from the front of the unit


All maintenance tasks can be carried out via front
access. During servicing, attachment and detachment
of parts is easier.
Comfortable
Auto swing (up and down) and wide-angle Drain pump kit is available as option
louvers (left and right by hand) facilitate even Installs onto side of unit.
Height of drain up
room temperature
Refrigerant
piping
Wide-angle louvers (by hand)
Soft material louver bends airflow over a wider area 1,000 mm

Indoor unit
Drain pump kit

Drain pump kit can be installed on either


left and right side of the indoor unit.

Interlock control
As an energy saving feature, the room air conditioning
unit can be interlocked with the key card system.

An air discharge modes ensure comfortable air Using a 3rd-party building management system,
distribution across the entire room air conditioning and lighting can be interlocked.
Auto-swing 5-level air direction setting
* Field setting with remote controller
Lighting

Interlock

Gettable to 5

Compact design and easy installation


different levels

Comfort even on the far side of the room


DIII-NET communication standard
To carry air to the far side of
long rooms, extra-high Connection to a centralised control system is available
airflow adds 10% more fan without option.
Navigation Wired LCD Wireless LCD speed the "high" setting. Air
Remote Controller Remote Controller Remote Controller discharge strength is
(Wired Remote Controller) A signal receiver must be added selected from the remote Easy cleaning
to the indoor unit. controller by field setting. Removable and washable grille

Switchable fan speed: High/Middle/Low

Auto airflow rate (When BRC1E62 is used)


Signal receiver unit
BRC1E62 BRC1C61 (Installed type)
Wireless remote controller is
Programme "Dry"
supplied in a set with a signal Dehumidification is microprocessor controlled to Flat panel, easy to wipe dust off
Note: Note: receiver.
Remote controller cable is not included and Remote controller cable is not included and BRC7EB519 prevent abrupt and uncomfortable changes in air Condensation does not easily form on and dirt does
must be procured locally. must be procured locally.
temperature. not cling to non-flocking flaps. It is easy to clean.
CEILING CASSETTE TYPE
15 (4-Way Flow) 16

FFR10/15C

Exclusive 4-Way Air Flow And Auto Forced On/Off Operation


Air Swing This feature enables you to operate the unit even if the
This feature is complemented by the powerful Turbo Mixed remote controller is misplaced or the remotes battery is
Flow Fan, cools remarkably fast and evenly to deliver weak. Preset at 24C cool mode, just press the forced on
extraordinary cooling efficiency. button for instant cooling comfort.

Elegantly Designed Panel Dry Mode Operation (Dehumidifying


The slim panel can be blended into any decoration and
design.
Operation)
Start with cooling to dehumidify and keeps the room dry
Wireless Remote Controller Wired Remote Controller
without much change in temperature.

Built-In High Head Drain Pump


The unit comes with a built-in high head drain pump up to
20mm (FFR-C) 700mm. A safety float is incorporated in the drain pump to
monitor its water level.
DGS01 DSLM8

Auto Random Restart


Compact and easy to use controller Prominent temperature display.
Prominent temperature display Real time clock display. 700mm
Real time clock display Easily accessible buttons. In the event of a sudden power failure during operation, unit
Easily accessible buttons for on/off, Key lock function can be automatically restart (subject to certain protection
Temperature setting, fan speed Real-time timer: 7 days option,
and mode control. 2 events daily
conditions) from last setting condition. This eliminates the
need to restart manually after each power failure.
CEILING CASSETTE TYPE
17 (ROUND Flow) 18
Avoids uneven temperature and discomfort caused by drafts:
Comfort enhanced by Round Flow!
360 airflow Air movement is gentle with Round Flow
With uniform temperature distribution Enhanced Comfort

FCQ50/60/71/ Airflow distribution 360 airflow can


100/125/140KA creates uniform maintain comfort
comfort throughout even if air discharge
the space. speed is lower.

Room remains Velocity decreases by


comfortable even when 25% when set
set temperature is temperature is raised
raised 1. 1 to 1.5.
Greater comfort

Adapts easily to the installation space


Because air flows out from corner outlets, comfort spreads more widely

Typical flow patterns: There are a total of 23 flow patterns.

All-round flow 3-way flow L-shaped 2-way flow Opposite 2-way flow

(E.g., installed in (E.g., installed (E.g., installed in (E.g., installed in


middle of ceiling) near a wall) a corner) a long room)
4-way flow also possible.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used
to close each unused outlet.
Operation sound increases when using 2-way or 3-way flow.

Grime prevention and antibacterial coating: Make cleaning easier:


Cassette air conditioner with 360 External panels are treated with a coating that repels dirt
uniform airflow sets the standard Treated surface Untreated surface

To prevent dirt sticking to the Resists


external panels, they have been soiling
Condition after exposure
Navigation Wired LCD Wireless LCD coated with a surface treatment Grimy to the smoke of 600
Remote Controller Remote Controller Remote Controller surface cigarettes in 1m3
(Wired Remote Controller) A signal receiver must be enclosed space.
added to the indoor unit.

Silver ion anti-bacterial Non-flocking flaps Filter has anti-mould


drain pan Condensation does not easily and antibacterial treatment
A built-in antibacterial treatment form on and dirt does not cling Prevents mould and
that uses silver ion in the drain to non-flocking flaps. It is easy microorganisms growing out of
BRC1E62 BRC1C61
Signal receiver unit
(Installed type)
pan prevents the growth of to clean. the dust and moisture that
Wireless remote controller is slime, bacteria, and mould that adheres to the filters.
supplied in a set with a signal
Note: Note:
BRC7F635F
receiver. cause smells and clogging.
Remote controller cable is not included and Remote controller cable is not included and
must be procured locally. must be procured locally.
19 20

Unified square panels Compact body and quiet operation Easier to maintain
Panel size is the same for all models, FCQ50-140KA. This feature is complemented by the powerful Turbo Mixed The condition of the drain pan With Ultra long-life filters (option), maintenance is not
It is easy to maintain a neat appearance when multiple Flow Fan, cools remarkably fast and evenly to deliver and drain water can be Drain plug
required in normal shops or offices for up to four years
units are installed in the same room. extraordinary cooling efficiency. checked by removing the drain
dB(A)
Sound pressure level plug and suction grille. Just open the
suction grille!
mm 95 Indoor unit
950 0m
m Same for
High Middle Low
50KA 35 31.5 28
all models 60KA 35 31.5 28 Options required for specific operating environments
71KA 35 31.5 28
100KA 43 37.5 32 Ultra long-life filter unit Branch duct (direct-connection round duct)
125KA 44 39 34
Optimal comfort and convenience 140KA 44 40 36
Even in dusty environments where the air conditioning is on A round duct can be attached without the need for a chamber.
A flanged port for direct connection of a round duct is
most of the time, the ultra long-life filter only has to be cleaned
assured by 2 air discharge modes Quick and easy to install once a year. provided. An existing branch duct chamber can also be fitted
Filter chamber (square slit hole).
Panel size is the same for all models, FCQ50-140KA.
Just 256 mm high. Installable in tight ceiling spaces (Can be used with high-efficiency filter)
It is easy to maintain a neat appearance when multiple
(5071KA) Fresh air intake kit
units are installed in the same room.
Setting to prevent soiling * 1 298 mm high Using this kit, a duct can be connected to take outdoor
Ultra long-life filter
Air direction Standard setting1 of ceiling2 (field setting) 256 mm *1 266 mm *2 with 100140KA air in.There are two Note 1.2
* 2 308 mm high
Recommended for shops with Dusty area: annual filter change chamber types that have Outside
Desired Standard setting to with 100140KA
situation prevent draft. light coloured ceilings that
must be kept spotless.
*For dust concentration of 0.3 mg/m3 (Requires separately sold Air purifier.) intake in two places: with
1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year
T-duct joint and without
Auto-swing Auto-swing between
15 and 60
Auto-swing between
25 and 60
Easy height adjustment Ordinary store or office: filter change every 4 years
*For dust concentration of 0.15 mg/m3
T-duct joint.
Each corner of the unit has 4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 12 month/years
5-levels
an Adjuster Pocket that lets
x 4 years
The units can be installed in the following
air direction
setting
Settable to 5 different
levels between 15 and 60
Settable to 5 different
levels between 25 and 60 you easily adjust the unit's different ways.
Auto air
The air direction is set automatically to the suspended height. High-efficiency filter unit Chamber type (without T-duct joint) Note 3.4
direction
control
memorised position of the previous air direction. aAvailable in two types: 65% and 90% colorimetry. KDDP55B160
Note: Filter chamber
Note: Flexible duct
If the wireless remote controller is (Can be used with ultra long-life filter)
(procured locally)
1
Air direction is set to the standard position when the unit is shipped from the factory.
The position can be changed from the remote controller.
installed, a signal receiver unit is housed
2
Closing of the corner discharge outlets is recommended. in one of the adjuster pockets. T-duct joint
(procured locally)
Suction
High-efficiency filter
Suitable for high ceilings All models can be installed without chamber Intake duct
(procured locally)
Connection (duct length: 4 m max.)
Even in spaces with high ceilings, a comfortable airflow using lifter because of the light weight chamber
is carried down to the floor level. Insulation kit for high humidity Chamber type (with T-duct joint) Note 3.4
Installed in any direction Please use if you think the temperature and humidity inside
the ceiling exceeds 30C and RH 80%, respectively.
KDDP55B160K
3.6 4.2 Since the orientation of the
3.2 m Flexible duct
m m suction grille can be adjusted Top panel insulation(1)
Top panel insulation(2)
after installing, the direction of the T-duct joint
Top panel insulation(3)
suction grille lines can be unified Insulation for decoration panel
Suction
Intake duct
Standard Setting Setting chamber
when multiple units are installed. Side panel insulation
(procured locally)
When all round flow is selected, ceilings up to 4.2 m in height Suspension bracket insulation
Connection
chamber
(duct length: 4 m max.)

can be accommodated. (100-140KA)


Drain pump is equipped as Direct installation type
Criteria for ceiling height and number of air discharge outlets
(Ceiling height is reference value) standard accessory with
850 mm Panel spacer KDDP55X160
Use when only minimal space is available between drop
Number of air discharge outlets used 850 mm lift ceilings and ceiling slabs.
175 mm
5071KA 100140KA
All round 4-way 3-way 2-way All round 4-way 3-way 2-way
flow flow flow flow flow flow flow flow
Standard 2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m Duct flange
Ceiling
height
High ceiling
High ceiling
3.0 m
3.5 m
3.4 m
4.0 m
3.3 m
3.5 m
3.8 m
-
3.6 m
4.2 m
3.9 m
4.5 m
4.0 m
4.2 m
4.2 m
-
Transparent drain socket 40mm
(with insulation material)
Intake duct
(procured locally)
Note: Factory settings are for standard ceiling height and all-round flow. Panel spacer
High ceiling settings (1) and (2) are set with the remote controller by field setting.
Note:
Note: Some ceiling constructions may hinder installation. Contact your Daikin 1 Use of options will increase operating sound.

Two selectable temperature-sensors DIII-NET communication standard Dealer before installing your unit. 2 Connecting ducts, fan, insect nets, fire dampers, air filters, and other parts should,
as required, be procured locally.
Connection to a centralised control system is available 3 When a local-procured fan is used, an interlock with air conditioner is necessary.
Optional PCB(KRP1C63) is required for interlocking.
without option. Sealing material of air discharge outlet
Switchable fan speed: High/Middle/Low
4 It is recommended that the volume of outdoor air introduced through the kit is
limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher
Sealing material block air discharge openings not used in quantities will increase the operating sound and may also influence temperature
Control of airflow rate has been improved from 2-step to
3-step.
Low gas pressure detection 2-way or 3-way blow. sending.
21 CEILING EXPOSED TYPE 22
Automatic Up and Down Air Swing Excellent Air Distribution
The motorized louver enables the air flow to be evenly The front vanes can be adjusted in four different directions
distributed. giving you the control over the units air to suit your
preferences.
Ceiling and Wall Installation Option
The FLR-E model is uniquely designed with the option to
install either below the ceiling or mounted at low wall
position to suit any interior design requirement.
FLR15E

* Wall bracket supplied


as optional item

Quiet Operation Auto Random Restart


Indoor noise level is kept at minimal by high efficient indoor It enables the units to restart automatically at different
fan. intervals when power resumes after a blackout.

Last Memory Strong and Robust


The unit restarts with the last restored setting when power The unit is built of rust resistant materials and robust parts
resumes. to ensure a long-lasting reliable service.

Wireless Remote Controller Wired Remote Controller

DGS01 DSLM8
Compact and easy to use controller Prominent temperature display.
Prominent temperature display Real time clock display.
Real time clock display Easily accessible buttons.
Easily accessible buttons for on/off, Key lock function
Temperature setting, fan speed Real-time timer: 7 days option,
and mode control. 2 events daily
23 CEILING EXPOSED TYPE 24
The latest Installation flexibility for
stylish model freedom of design
Sophisticated design
Flexible installation
Flap neatly closes The unit fits more snugly into tight spaces.
when not in use.

FHQ50/60/71/ White colour


100/125/140DA 30 mm 30 mm
or more or more

Comfortable *Water used in the test-run can be drained from the air discharge opening rather than from the
side as was formerly the case.
The technology of the DC fan motor, wide sirocco
fan, and large heat exchanger combine for greater Drain pump kit (option) can
airflow and quiet operation be easily incorporated 600
mm
Drain pipe connection can be
Auto swing (up and down) and louvers (left and right done inside the unit.
by hand) bring comfort to the room Refrigerant and drain pipe
Drain pump kit
outlets are at the same (built inside
Louver manually adjusts for straight or wide angle opening. the unit)
airflow

DIII-NET communication standard


Connection to a centralised control system is available
without option.

All wiring and internal servicing can be done from


under the unit

Suitable for high ceilings Easier piping work for rear side
by removable frame

4.3
3.5 m
m
Easy maintenance
Drain pump kit (option) includes a silver ion
50-71DA 100-140DA
antibacterial agent that assists in preventing the
50-71DA 100DA 125/140DA growth of slime, bacteria, and mould that cause
Standard 2.7m or less 3.8m or less 4.3m or less smells and clogging

Comfortable airflow travels


High ceiling 2.7m~3.5m 3.8m~4.3m -
Note: Factory settings is standard.
Non-flocking flap

throughout the room


High ceiling are set with remote controller by field setting.
Condensation does not easily
form on and dirt does not cling
Two selectable temperature-sensors
to non-flocking flap.
It is easy to clean.
Switchable fan speed: High/Middle/Low Non-flocking flap
Navigation Wired LCD Wireless LCD
Remote Controller Remote Controller Remote Controller Programme "Dry" Easy-clean, flat surfaces
(Wired Remote Controller) A signal receiver must be It is easy to wipe dirt off the flat side and lower surfaces
added to the indoor unit.
of the unit.
Quiet operation
Sound pressure level dB(A)
Indoor unit
High Middle Low Oil resistant grille
50/60DA 37 35 32 Oil-resistant plastic is used for the air suction grille.
Signal receiver unit This satisfies durability in restaurants and other
BRC1E62 BRC1C61 (Installed type) 71DA 38 36 34
Wireless remote controller is
100DA 42 38 34 similar environments.
supplied in a set with a signal
Note: Note: receiver. Note: Intended for use in salons, dining rooms, and ordinary sales
Remote controller cable is not included and Remote controller cable is not included and BRC7GA56 125DA 44 41 37
floors, this specification is not suitable for kitchens or other harsh
must be procured locally. must be procured locally. 140DA 46 42 38 environments.
25 CEILING CONCEALED TYPE 26
Hidden Comfort
The application of the FDMR series are installed conveniently above the ceiling, making it an ideal cooling choice for both
commercial and residential segments. Highly recommended for restaurants, offices and houses with enough ceiling
height.

Evergreen Prestige
Unlike other indoor units split air-conditioning, FDMR series wont tarnish along with time. With its unique concealed
FDMR 10/15C application, FDMR series stays evergreen forever.

Even Air Distribution


The ducting system distributes air flow remarkably even to all corners of the room, delivering option cooling efficiency and
comfort.

Power Failure Power Resume

Auto Random Restart Operation Stop Restart

Once power resumes after a blackout,


the unit will restart automatically at its last setting condition.
This eliminate the need to restart manually
after each power failure. E2 PROM Setting stored before power failure.

Built-In Starter
Protect air conditioner from overcurrent condition that may cause system failure. This will prolong the units lifespan as the
unit will be protected from overcurrent.

Wired Remote Controller

DSLM8
Prominent temperature display
Real time clock display
Easily accessible buttons
Key lock function
Real-time timer: 7 days option,
2 events daily
27 CEILING CONCEALED TYPE 28
Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
Door-installed Wall-installed
When air conditioning two rooms simultaneously, ventilation grille ventilation grille Under-door cutout
the air discharged into each room must be
circulated back to the air conditioner. To achieve
this, a ventilation duct should be installed for Ventilates air through
Partitioning wall
each room or one of the indicated ventilation the partitioning wall.
grilles should be installed on the partitioning wall (See right)

or under the door between the rooms. Ventilation grille Ventilation grille Under-door cutout

FBQ50/60/71/ Note: The under-door cutout method should be used only when there is a small volume of airflow.

100/125/140E Design and installation flexibility Airflow rate auto adjustment function
With a height of only 245 mm, installation Controls the airflow rate using a remote controller
is possible even in buildings during test run.
with narrow It is automatically adjusted to approximately 10% of
ceiling spaces 245mm the rated H tap airflow.

One of the industrys most compact bodies in the mid-static pressure range. Interlock control
Indoor unit 50/60/71E 100/125/140E As an energy saving feature, the room air conditioning
Height (mm) 245 unit can be interlocked with the hotel key card system.
Width (mm) 1,000 1,400
Depth (mm) 800 Using a 3rd-party building management system, air
conditioning and lighting can be interlocked.
Higher lift is realized by utilising built-in DC drain
* Field setting with remote controller
pump with standard accessory
Middle & High static
850mm pressure type
(FBQ-D series)

700mm Interlock

Bottom suction is available


Wiring and servicing
DIII-NET communication standard
can be done from unit joist
Easier communication and connection with the
the underside of the
centralised control system.
unit (an option part Air suction

required). ceiling
Comfort
Rear suction Bottom suction Switchable fan speed:High/Middle/Low and Auto
Air suction flange Sield plate for side plate(option) (Auto is applicable when BRC1E62 is used.)

Clean
Silver ion anti-bacterial drain pan
A built-in antibacterial treatment that uses silver ion in
the drain pan prevents the growth of slime, bacteria,

Thinner design allows greater installation flexibility


Control box
cover Bottom
Switch bottom plate
with air suction flange. Air suction and mould that cause smells and clogging.
plate Make the control box flange
Bottom plate
Easy maintenance
face inward.

Position of drain pan inspection opening has


been modified for easier inspection work

Navigation Wired LCD Wireless LCD Control box cover


Drain pan maintenance check window
Remote Controller Remote Controller Remote Controller Control box faces outward. Control box faces inward. This makes it possible
(Wired Remote Controller) A signal receiver must be added to inspect for drain pan
Inspection
to the indoor unit. Using a DC fan motor, the external static dirt and to confirm opening for
drainage during drain pan
pressure can be controlled to within a range installation without the Drain pan
of 50 Pa to 150 Pa use of tools. maintenance
check window
Adjustable external static pressure
Easy maintenance because the drain pan can be
50 Pa 150 Pa
Signal receiver unit removed
BRC1E62 BRC1C61 (Separate type) Set to low static Set to high static pressure for

Note: Note:
Wireless remote controller is
supplied in a set with a signal
receiver.
pressure when ducts
are short.
advanced needs such as when
using dampers and long ducts. High efficiency
Remote controller cable is not included and Remote controller cable is not included and BRC4C66
Comfort airflow is achieved in accordance with conditions such as DC fan motor and DC drain pump are utilised to
must be procured locally. must be procured locally.
duct length. improve energy efficiency
Technology for
29 Compact Outdoor unit energy efficiency 30

The high efficiency compressor to achieve


RZR100MVM
a high COP
RZR125MVM
Compressor equiped with
RZR140MVM 1
RZR50MVM RZR100MYM Reluctance DC motor
RZR60MVM RZR125MYM Daikin DC Inverter models are equipped with the 3
RZR71MVM RZR140MYM Reluctance DC motor for compressor.

The Reluctance DC motor uses 2 different types of


Easy installation and maintenance Durability torque, neodymium magnet*1 and reluctance 2
Pre charged for up to 30 metres As the bottom frame is subject to corrosion,
torque*2.
If the refrigerant piping length does not exceed 30m, a corrosion-proof galvarium steel plate is
there is no need for on-site gas charging. adopted to enhance the durability 1
This motor can save energy because it generates
Heat exchange fins are provided with
Long piping length more power with a smaller electric power than an AC
anti-corrosion treatment (RZR50-71M)
Allowed refrigerant piping length and level difference or previous DC motor.
Construction
ALL model
Non-treated fin Aluminium
Pre charged1 30 m
Hydrophilic treatment
Anti corrosion Aluminium
50 m
Max. length (Equivalent length 70m) treated fin Corrosion resistant resin Reluctance DC Motor Reluctance Swing compressor
DC motor
Max. level Energy savings is realised, eliminating

Motor efficiency
30 m
difference
1
Night quiet operation mode the friction and the leakage of
Note : Additional refrigerant charging is required if the refrigerant pipe is longer
The Automatic night quiet mode will initiate DC motor refrigerant gas.
than the length.
8 hours after the peak temperature is reached in More than 20% Swing bushing
4-direction piping offers greater layout freedom the daytime, and normal operation will resume Refrigerant gas
(RZR100-140 only) AC motor

The outer panel for the piping connection part of the 10 hours after that
Reducing noise will reduce capacity slightly.
front, right side and backside can be removed and is
easier for post-installation piping work.
1 Rotational speed
Sound pressure level (dB(A)) Note :
1
Anechoic chamber conversion Small load Large load
Rated2 Night Quiet Mode value, measured according to Low capacity High capacity

Removable part of bottom RZR50/60/71MVM 48 44


JIS parameters and criteria.
During operation these values Note:
*1. A neodymium magnet is approximately 10 times
stronger than a standard ferrite magnet.
frame makes the piping RZR100MVM/MYM 49 45
are somewhat higher owing to
ambient conditions.
Data are based on studies conducted under *2. The torque created by the change in power Piston by incorporated blade and roller.
controlled conditions at a Daikin laboratory. between the iron and magnet parts.
work easier Separation
RZR125MVM/MYM 52 45 2
Value when cooling. Value will
differ when heating.
available RZR140MVM/MYM 54 45

2 Fan
Peak outdoor temperature
Facilitates pump down (Refrigerant recovery function)
A pump-down switch is provided to make it easier to
Capacity (%)

100
collect refrigerant if the unit is to be moved or layout V-cut Propeller Fan (RZR50-71M) Aero Spiral Fan (RZR100-140M)
modified. 8 hours
10 hours
Through use of a V-cut propeller fan that imitates the The Aero Spiral Fan features fan blades with the
50
* Pump-down function is available for pre-charged refrigerant amount. efficiency of the swan, a migratory bird, airflow bent blade edges, further reducing turbulence.
Load (%)

becomes smooth and loss is reduced.


Low gas pressure detection function 0
48
With the bent
blade edge
Without the bent
blade edge
Effective gas monitoring reduces the labor required
Sound (dB(A))

Rated
Operation

for operation, maintenance, and repairs. 44 Quiet mode


Quiet mode

8:00 12:00 16:00 20:00 0:00 4:00 8:00


Compact and lightweight Note : Daikin date for RZR71MVM Operating sound about 4 dB quieter

Reduced installation work thanks to light, compact


outdoor unit. Demand Control Function Escaping eddies are sucked in by the
bent blade edges, reducing overall
Comparison of outdoor units By setting limits that restrict power 550 turbulence.
Imitating the performance
LVVM NEW MVM
consumption, you can cut electricity bills V-cut propeller fan of the swan
Maximum power use is maintained within a set level of system
Height 1,170 mm 990 mm capacity. This enables effective demand control while DC fan motor structure
Weight 97 kg 65 kg maintaining comfort. Maximum power consumption can be set at
40, 60, 70, 80, or 100%.
Reduced by
* Field setting
* Required for KRP58M51 (Option) 3 DC fan motor
180 mm Limitation
990
consumption

mm Reduced by Efficiency improved in all areas compared to AC


Power

(RZR100-140 only)
32 kg motors, especially at low speeds.

RZR140LVVM RZR140MVM 8:00 12:00 16:00 20:00Time


REMOTE CONTROLLER
31 Optional accessory 32

Easy-to-read LCD remote controller allows various system Wired LCD Remote Controller Wireless LCD Remote Controller

control configurations and can control multiple indoor units.


Remote controller options are shown on the page introducing each indoor unit model.

Navigation Remote Controller BRC1C61 Wireless Remote Signal Receiver Unit


(Wired LCD Remote Controller) Controller (For Ceiling Cassette
This simple, modern designed remote controller with fresh white colour [Round Flow Type])

matches your interior design. Operation is much easier and smoother, Easy to read because of large LCD screen. The wireless remote controller is supplied in a set with
just follow the indications on the navigation remote controller. The rubber switch and the oil-resistant plastic casing a signal receiver.
are adopted for durability. Signal receiver unit is contained inside decoration
Only 17 mm thick. Can be installed either recessed panel or indoor unit.
BRC1E62 or exposed. Shape of signal receiver unit differs according to the
indoor unit.
Backlight display Note: The signal receiver unit shown in the photograph is for mounting inside
the decoration panel of the ceiling cassette (round flow type).

Clear Display
Dot matrix display Wired remote controller Facilitates maintenance SkyAir shares common
A combination of fine dots enables various icons. has built-in temperature- and repair control with Heat
Large text display is easy to see. All initial settings can be set from
sensor Reclaim Ventilator and
the remote controller. After
(Applies to wired remote controllers (BRC1C61/1E62)

Enables temperature sensing interior construction is complete, the other Daikin


closer to target area for improved ceiling cassette (round flow air-conditioning units,
Energy Saving
Setpoint auto reset Setpoint range set
comfort. (When using remote type) can be remotely set thus simplifying
control from another room, without having to use stepladder
access for manual setting.
interlocking operations.
- Even if the set temperature is changed, after a preset period new set - Saves energy by limiting the temperature-sensor in indoor unit's Easily adaptable to large-scale,
temperature returns to preset value. min. and max. set air inlet must be selected.) Setting contents: High ceiling use, air direction, filter
type, address for centralised control (group control high-function, centralised remote
- Period selectable from 30, 60, 90, or 120 min. temperature. address is set automatically).
control systems.
- Avoids excessive heating or
Restaurant example Remote controller is equipped
cooling. Installing and connecting control
Restaurant opened Full tables at lunchtime After 30 minutes* with model name and failure
- This function is convenient if wiring between SkyAir and other
Temperature is set to 27C Then is lowered to 24C for Automatically returns to preset display functions. This facilitates
crowded room temperature (27C) the remote controller is Daikin air-conditioning equipment
Returns to service in the unlikely event of a
27C 27C installed where anyone can is easy.
24C malfunction.
automatically change the settings. (Model name display function applies to BRC1E62 only.)

*Preset-return time can be set


Wireless remote controller for each indoor unit type
at 30, 60, 90, or 120 min
CEILING CASSETTE (ROUND FLOW TYPE) BRC7F635F
Off timer (programmed) CEILING EXPOSED TYPE BRC7GA56
- Sets and saves setting for an increment of time that automatically turns off WALL MOUNTED TYPE BRC7EB519
air conditioner after a preset period of time for each time operation starts. CEILING CONCEALED TYPE BRC4C66
- Period can be preset from 30 to 180 minutes in10-minute increments.

LCD panel shows operating status in letters, numbers, and motion.


Convenience Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.
Weekly schedule Multilingual display
- 5 actions per day can be scheduled for each day Display is available in 11 Preset temperature /
Displays preset room temperature and operating status (fan, dry, cool).
of the week. languages. operation mode display
- The holiday function will disable schedule timer (English, German, French, Spanish, Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows when
Italian, Portuguese, Greek, Dutch, Programming time display
for the days that have been set as holiday. Russian, Turkish, and Polish).
it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.
- 3 independent schedules can be set. Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.

(e.g. summer, winter, mid-season)


REMOTE CONTROLLER
33 Optional accessory FUNCTIONS 34

System variation to control multiple indoor units


Control pattern Wired remote controller Wireless remote controller
Functions CEILING CASSETTE TYPE CEILING EXPOSED TYPE CEILING CONCEALED TYPE

Control By 1 (Basic system)


Overview INDOOR UNIT FFR10/15CV1 FLR15EV1L/M FDMR10/15CV1M
Remote Controller
Non-polar, double-core Signal receiver unit installed OUTDOOR UNIT RR10/15DV1 RR15DV1 RR10/15DV1
(max. wiring length 500 m) on indoor unit
Auto swing
Control by 1 wireless remote
For control from 2 controller and 1 wired remote
Swing pattern selection
Control By 2 locations such as in controller (See note 2, 3) DC fan motor (Indoor unit)
Remote Controllers room and control room, Signal receiver unit installed Comfort
exits, etc. Connects 2 wired remote
on indoor unit
Switchable fan speed
controllers (See note 1)
Auto airflow rate
Programme Dry
For simultaneous
Group Control control of up to 16 Remote Real time timer, 7 days option, 2 events daily *1 *1 *1
indoor units. Controller
Automatic address setting function Automatic address setting function On/Off timer
Signal receiver unit installed
on 1 indoor unit Saranet filter *2
Cleanliness
Drain pan
Operation and monitoring
Control By is carried out using the (Command from outside) (Command from outside)
Drain pump mechanism
contact signal from the
External Command operation control box in Work &
Pre-charged for up to 7.5m
the monitoring room. Optional wiring adaptor for Optional wiring adaptor for servicing
electrical appendices is necessary electrical appendices is necessary Self-diagnosis function
Central remote controller (option)
Central remote controller (option)
Control features Auto-restart
Centralised control of
Centralised up to 64 indoor groups High efficiency hydrophilic indoor fin
Remote Control from remote location Others
Anti corrosion treated heat exchangers *2 *2 *2
up to 1 km away.
Note: *1 : Applicable when DSLM8 is used
*2 : Option

Heat Reclaim Heat Reclaim


Ventilator Ventilator
Link by remote
controller group control.
Can be operated simultaneously Can be operated simultaneously
or independently by remote controller by remote controller
Interlock Control (set by ventilation mode) (set by ventilation mode)

With Heat Reclaim Central remote controller (option) Central remote controller (option)

Ventilator
Zone link control by
centralised control. Heat Reclaim Heat Reclaim
Ventilator Ventilator

Heat Reclaim Ventilator for indoor units within a zone are operated by Heat Reclaim Ventilator for indoor units within a
interlocking Can also be operated independently by remote controller. zone are operated by interlocking

Note: 1BRC1E62 can connect to BRC1E62 only. 2It is not possible to use two wireless remote controllers. 3BRC1E62 cannot connect to wireless remote controller.

Easily adaptable to large-scale, high-function, centralised remote control system.


Central remote controller Unified on/off controller Schedule timer
DCS302CA61 (Option) DCS301BA61 (Option) DST301BA61 (Option) DCS601C51 (Option)

Centralised control, with setting as Centralised control of on/off by group Unified control of weekly schedule for With its high functionality, the full
simple as it is with a standard remote or all at once for up to 256 indoor up to 1,024 indoor units. colour all-in-one graphic controller
controller, of up to 64 groups (1,024 units. Schedule timer sets on/off time in 1 minute units facilitates management of SkyAir
indoor units) is possible. to be executed twice a day for a week at a time. System in a variety of ways.
35 Functions 36

Functions Abundance of functions that provide comfortable


WALL MOUNTED CEILING CASSETTE CEILING EXPOSED CEILING CONCEALED
TYPE TYPE TYPE TYPE

air-conditioning in stores and offices.


Overview INDOOR UNIT FAQ100CVEA FCQ50-140KAVEA FHQ50-140DAVMA FBQ50-140EVE
Note: Some features only available on selected models. See overview pages for full list of features applicable to each unit.

RZR100MVM RZR50-140MVM RZR50-140MVM RZR50-140MVM


Comfort
OUTDOOR UNIT
RZR100MYM RZR100-140MYM RZR100-140MYM RZR100-140MYM Auto-swing Programme "Dry"
Auto swing Delivers comfortable air-conditioning to all areas, near to and far from Dehumidification is microprocessor controlled to prevent abrupt and
the air-conditioner. uncomfortable changes in air temperature. Useful for reducing
Swing pattern selection The air flow direction can be fixed at your desired angle by the remote uncomfortable humidity without uncomfortable cooling of the room.
DC fan motor (Indoor unit) controller.
Switchable fan speed 3 step 3 step 3 step 3 step
High-ceiling application
*3
Swing pattern selection Delivers air-conditioning
Auto airflow rate *3 You can freely set air discharge settings by remote controller. comfort all the way
Comfort down to the floor in
High fan speed mode (1) Standard (2) Draft prevention (3) Ceiling soiling
setting setting prevention setting air-conditioning zones
Programme Dry
with high ceilings.
High ceiling application *5
Note:
Two selectable temperature-sensors *1 When units are installed on high ceilings, depending on the model, various restrictions
concerning maximum height, air discharge direction, and choice of options may apply.
Night quiet operation *2

Setpoint auto reset *3 Independent up-and-down airflow Two selectable temperature-sensors


Temperature-sensors are included in the indoor unit and optional
Independently adjust (manually) the eight horizontal blade louvers in
Setpoint range set *3 wired remote controller. Temperature sensing closer to target area is
both up and down directions to achieve an airflow that reduces
Remote Weekly schedule timer *3 uneven room temperature.
possible to further increase the comfort level.
Controller
Off timer (programmed) *3 Use the temperature-sensor in the
On/Off timer *4 DC fan motor (indoor unit) indoor unit when controlling air
DC fan motor improves efficiency. conditioning from another room.
Anti-bacterial air filter *6
Switchable fan speed Note: Wireless remote controllers have no
Cleanliness Mould-proof air filter High setting provides maximum reach while low setting minimises
temperature-sensor.

Silver ion anti-bacterial drain pan drafts.


Year-round cooling applicable
Efficient cooling even in winter when the indoor temperatures are
Drain pump mechanism *6 *6 Auto airflow rate higher than those outside, such as in underground public spaces or
Airflow rate is automatically controlled in accordance with the offices with many computers.
Pre-charged for up to 30 m *2 difference between room temperature and set temperature.
Long-life filter *6 Night quiet operation
Work & Filter sign High fan speed mode The Automatic night quiet mode will initiate 8 hours after the peak
servicing You can increase fan speed approximately 10% higher than the "high" temperature is reached in the daytime, and normal operation will
Ceiling soiling prevention setting. resume 10 hours after that.
Low gas pressure detection *2
Emergency operation
Remote Controller
Self-diagnosis function
Setpoint auto reset Off timer (programmed)
Auto-restart Even if the set temperature is changed, after a preset period Sets and saves setting for an increment of time that automatically
new set temperature returns to preset value. turns off air conditioner after a preset period of time for each time
Control by 2 remote controllers operation starts.
Group control by 1 remote controller Setpoint range set
Control External command control *6 *6 *6 *6 Saves energy by limiting the minimum and maximum set On/Off timer
features temperatures. Avoids excessive heating and cooling. Operation starts when the preset time of the ON timer elapses and
Central remote control stops when the preset time of the OFF timer elapses.
Interlock control with Heat Reclaim Ventilator Weekly schedule timer
DIII-NET communication standard Up to five operation ON/OFF settings can be programmed per day for
each day of the week. Not only can the time be set for the operation
ON setting, but also the temperature.
High-efficiency filter
Options Ultra long-life filter
Fresh air intake kit Cleanliness
Anti-bacterial air filter Silver ion anti-bacterial drain pan
Others Anti corrosion treated heat exchangers *2 *7 *7 *7 The air filter has an anti-bacterial treatment to help prevent the growth A built-in antibacterial treatment that uses silver ion in the drain pan
of bacteria and mould on it. prevents the growth of slime, bacteria, and mould that cause smells
Note: *1 : Applicable when wired remote controller is used *5 : Installable on max. 3.5 m(50-71) and 4.3 m (100-140) high ceiling
and clogging.
*2 : For outdoor units *6 : Option
*3 : Applicable when BRC1E62 is used *7 : RZR50-71 only Mould-proof air filter
*4 : Applicable when BRC1C61 is used Sanitary filter has mould-resistant treatment.
37 FUNCTIONS SPECIFICATIONS 38

WALL MOUNTED
Work and Servicing Capacity
hp4 4.0 4.0

kW4 100 100


Drain pump mechanism Ceiling soiling prevention Indoor FAQ100CVEA FAQ100CVEA
Steeper gradient realises more Daikin's innovative air discharge mechanism keeps airflow away from Model
Outdoor RZR100MVM RZR100MYM
efficient condensate drainage. the ceiling. Ceiling cleaning is less frequently required.
Btu/hr 34,100 (17,100-38,200)
High-lift is especially useful for long Rated Cooling Capacity (Min-Max)
lengths of drain piping. Low gas pressure detection kW 10.0 (5.0-11.2)

Insufficient gas charging is normally hard to detect. During test run Power Consumption kW 3.37

Pre charged for up to 30 m after installation and regular inspection, the refrigerant level is Running Current, 1[3] A 16.28 [5.40]

If refrigerant piping length does not exceed 30m, there is no need monitored by a microprocessor to maintain proper gas pressure. COP W/W 2.97

for on-site gas charging. Reliability is assured and maintenance and inspection can be carried CSPF Wh/Wh 4.01

*Applicable to RZR series. RKS/RXS series: 10m


out more quickly. Refrigerant Type R410A
Air Flow Rate (H/M/L) CFM 918/812/671
Emergency operation Power Source Outdoor V/Ph/Hz 220-240/1/50 380-415/3/50
Long-life filter Even if there is a malfunction elsewhere in the system, the fan or Indoor (H/M/L) dBA 49/45/41
Maintenance is not required for one year*. compressor can still be operated. (depending on the malfunction) Sound Pressure Level
Outdoor dBA 49
The filter is washable and can be reused.
Dimension Indoor mm 340x1,200x240
* For dust concentration of 0.15mg/m3 Self-diagnosis function (H X W X D) Outdoor mm 990x940x320
The operating parameters of indoor and outdoor units, and sensor
Indoor kg 17
Filter sign data at critical locations throughout the system, are constantly Unit Weight
Outdoor kg 65 73
The filter sign warns you when it is time to clean the filter. monitored using a microcomputer. To facilitate quick response in the
Outdoor Coil Type Micro Channel
* When using a wired remote controller the sign is displayed in the LCD. When using a event of a malfunction, a message appears on the LCD of the remote
Liquid mm/in 9.52 / 3/8
wireless remote controller the filter sign lamp illuminates on the signal receiver unit. controller and an LED on the unit illuminates. Copper Pipe Size
Gas mm/in 15.88 / 5/8
Max. Interunit Piping Length m 50 (Equivalent length 70)
Max. Installation Level Difference m 30
Control features Heat Insulation Both liquid and gas piping
NOTE :
Auto-restart Central remote control 1. DUE TO PRODUCT INNOVATION, ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW:
If there is a power outage while the equipment is operating, Optional central remote controller enables centralised control of up to COOLING 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR.
operations will restart in the same mode as before the power cut 1024 indoor units (64 groups) from up to 1 km away. 3. SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION,
when electricity is restored. THE SOUND PRESSURE LEVEL WILL BE HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION.
Interlock control with Heat Reclaim Ventilator 4. CAPACITY (hp) AND (kW) ARE FOR EASE OF REFERENCE ONLY.
Control by 2 remote controllers Enables interlocking control with external equipment such as Heat
Using 2 remote controllers you can operate the equipment locally or Reclaim Ventilator.
from a remote location.
Note: When a wireless remote controller is used, remote control by two remote controllers
is not possible.
DIII-NET communication standard
Standardly equipped interface enables connection to centralised
Group control by 1 remote controller control system without need of an adaptor.
You can turn up to 16 indoor units on/off with a single remote
controller. (When using connected indoor units, the settings must all
be the same and on/off will be simultaneous.)

External command control


Operation and monitoring is carried out using the contact signal from
the operation control box in the building monitoring room.
*An option is required.

Options
High-efficiency filter Fresh-air intake kit
Two types are available: 65% and 90% colorimetry. You can provide air-conditioning with fresh air from outside.
Convenient for places where a ventilation fan cannot be installed.
Ultra long-life filter
Requires no maintenance for about 4 years* (10,000h) in stores and
offices.
*For dust concentration of 0.15 mg/m3

Others
Anti corrosion treated heat exchangers
To achieve increased durability by improved resistance to salt
corrosion and atmospheric pollution, Anti corrosion treated fin for heat
exchangers (with special coating) are used for the heat exchanger of
the outdoor unit. In high corrosive areas, regular maintenance needs
to be carried out.
39 SPECIFICATIONS SPECIFICATIONS 40

CEILING CASSETTE (4 way flow) CEILING EXPOSED


hp 5 1.0 1.5 hp5 1.5
Capacity Capacity
kW 5 25 35 kW5 35
Indoor FFR10CV1 FFR15CV1 Wireless FLR15EV1L
Model Indoor
Outdoor RR10DV1 RR15DV1 Model Wired FLR15EV1M
Btu/hr 9,500 (3,650-12,000) 12,500 (4,800-14,000) Outdoor RR15DV1
Rated Cooling Capacity (Min-Max)
W 2,780 (1,070-3520) 3,660 (1,410-4,100) Btu/hr 12,500 (5,400-14,000)
Rated Cooling Capacity (Min-Max)
Power Consumption (Min-Max) W 770 (300-1,202) 940 (343-1,230) W 3,660 (1,580-4,100)
Running Current (Min-Max) A 4.08 (1.66-5.53) 4.45 (2.01-5.63) Total Power (Min-Max) W 910 (374-1,252)
COP W/W 3.61 3.89 Total Current (Min-Max) A 4.32 (2.03-5.72)
Refrigerant Type R410A COP W/W 4.02
Air Flow Rate (H/M/L) CFM 400/390/370 410/390/360 Refrigerant Type R410A
Power Source Indoor V/Ph/Hz 220-240/1/50 Air Flow Rate (H/M/L) CFM 508/386/350
Indoor (H/M/L) dBA 44/41/38 45/42/38 Power Source Indoor V/Ph/Hz 220-240/1/50
Sound Pressure Level
Outdoor dBA 48 Indoor (H/M/L) dBA 46/38/35
Sound Pressure Level
Dimension Outdoor dBA 48
Indoor mm 250x570x570 (295x640x640)
(With Panel) Dimension Indoor mm 218x1,080x630
(H X W X D) Outdoor mm 550x765x285 (H X W X D) Outdoor mm 550x765x285
Indoor+Panel kg 16+2
Unit Weight Indoor kg 24
Outdoor kg 31 33 Unit Weight
Outdoor kg 33
Outdoor Coil Type Cross Fin Coil
Outdoor Coil Type Cross Fin Coil
Liquid mm/in 6.35 / 1/4
Copper Pipe Size Liquid mm/in 6.35 / 1/4
Gas mm/in 9.52 / 3/8 12.7 / 1/2 Copper Pipe Size
Gas mm/in 12.7 /1/2
Max. Interunit Piping Length m 15
Max. Interunit Piping Length m 15
Max. Installation Level Difference m 10
Max. Installation Level Difference m 10
Heat Insulation Both liquid and gas piping
Heat Insulation Both liquid and gas piping
NOTE :
1. DUE TO PRODUCT INNOVATION, ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 1. DUE TO PRODUCT INNOVATION, ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2. ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARD ISO5151. 2. ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARD ISO5151.
3. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW: 3. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW:
COOLING 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR. COOLING 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR.
4. SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, 4. SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION,
THE SOUND PRESSURE LEVEL WILL BE HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION. THE SOUND PRESSURE LEVEL WILL BE HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION.
5. CAPACITY (hp) AND (kW) ARE FOR EASE OF REFERENCE ONLY. 5. CAPACITY (hp) AND (kW) ARE FOR EASE OF REFERENCE ONLY.

CEILING CASSETTE (round flow) CEILING EXPOSED


hp4 2.0 2.5 3.0 4.0 5.0 6.0 4.0 5.0 6.0 hp4 2.0 2.5 3.0 4.0 5.0 6.0 4.0 5.0 6.0
Capacity Capacity
kW4 50 60 71 100 125 140 100 125 140 kW4 50 60 71 100 125 140 100 125 140
Indoor FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA Indoor FHQ50DAVMA FHQ60DAVMA FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA
Model Model
Outdoor RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR125MVM RZR140MVM RZR100MYM RZR125MYM RZR140MYM Outdoor RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR125MVM RZR140MVM RZR100MYM RZR125MYM RZR140MYM
17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800 17,100 20,500 24,200 34,100 42,700 47,800 34,100 42,700 47,800
Btu/hr (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600) Btu/hr
Rated Cooling Capacity (Min-Max) Rated Cooling Capacity (Min-Max) (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600)
kW 5.0 (2.3-5.6) 6.0 (2.6-6.3) 7.1 (3.2-8.0) 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4) 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4) kW 5.0 (2.3-5.6) 6.0 (2.6-6.3) 7.1 (3.2-8.0) 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4) 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4)
Power Consumption kW 1.24 1.58 1.99 2.78 4.31 5.62 2.78 4.31 5.62 Power Consumption kW 1.24 1.58 2.37 3.03 4.42 5.55 3.03 4.42 5.55
Running Current, 1[3] A 5.99 7.63 9.61 13.43 20.82 27.15 [4.46] [6.91] [9.01]
Running Current, 1[3] A 5.99 7.63 11.45 14.64 21.35 26.81 [4.86] [7.09] [8.90]
COP W/W 4.03 3.80 3.57 3.60 2.90 2.49 3.60 2.90 2.49
COP W/W 4.03 3.80 3.00 3.30 2.83 2.52 3.30 2.83 2.52
CSPF Wh/Wh 6.47 6.19 5.99 5.13 5.00 4.85 5.13 5.00 4.85
CSPF Wh/Wh 6.18 5.99 5.74 5.01 4.99 4.69 5.01 4.99 4.69
Refrigerant Type R410A
Refrigerant Type R410A
Air Flow Rate (H/M/L) CFM 741/618/477 1,130/918/706 1,165/988/794 1,130/918/706 1,165/988/794
Air Flow Rate (H/M/L) CFM 530/424/353 724/600/494 988/847/706 1,094/953/812 1,200/1,024/847 988/847/706 1,094/953/812 1,200/1,024/847
Power Source Outdoor V/Ph/Hz 220-240/1/50 380-415/3/50
Power Source Outdoor V/Ph/Hz 220-240/1/50 380-415/3/50
Indoor (H/M/L) dBA 35/31.5/28 43/37.5/32 44/39/34 44/40/36 43/37.5/32 44/39/34 44/40/36
Sound Pressure Level Indoor (H/M/L) dBA 37/35/32 38/36/34 42/38/34 44/41/37 46/42/38 42/38/34 44/41/37 46/42/38
Outdoor dBA 48 49 52 54 49 52 54 Sound Pressure Level
Outdoor dBA 48 49 52 54 49 52 54
Dimension Indoor mm 256x840x840 (296x950x950) 298x840x840 (338x950x950) Dimension Indoor mm 235x960x690 235x1,270x690 235x1,590x690
(With Panel)
(H X W X D) Outdoor mm 595x845x300 990x940x320
(H X W X D) Outdoor mm 595x845x300 990x940x320
Indoor kg 25 32 38
Indoor+Panel kg 21+5.5 24+5.5 Unit Weight
Unit Weight Outdoor kg 43 65 73
Outdoor kg 43 65 73
Outdoor Coil Type Hydrophilic Cross Fin Coil Micro Channel Outdoor Coil Type Hydrophilic Cross Fin Coil Micro Channel
Liquid mm/in 9.52 / 3/8 Liquid mm/in 9.52 / 3/8
Copper Pipe Size Copper Pipe Size
Gas mm/in 15.88 / 5/8 Gas mm/in 15.88 / 5/8
Max. Interunit Piping Length m 50 (Equivalent length 70) Max. Interunit Piping Length m 50 (Equivalent length 70)
Max. Installation Level Difference m 30 Max. Installation Level Difference m 30
Heat Insulation Both liquid and gas piping Heat Insulation Both liquid and gas piping

NOTE : 1. DUE TO PRODUCT INNOVATION, ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
1. DUE TO PRODUCT INNOVATION, ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW:
2. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW: COOLING 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR.
COOLING 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR. 3. SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION,
3. SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE SOUND PRESSURE LEVEL WILL BE HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION.
4. CAPACITY (hp) AND (kW) ARE FOR EASE OF REFERENCE ONLY.
THE SOUND PRESSURE LEVEL WILL BE HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION.
4. CAPACITY (hp) AND (kW) ARE FOR EASE OF REFERENCE ONLY.
41 OPTIONS OPTIONS 42

CEILING CONCEALED
1.0 1.5
INDOOR UNIT
hp5
Capacity
kW5 25 35

Model
Indoor FDMR10CV1M FDMR15CV1M WALL MOUNTED
Outdoor RR10DV1 RR15DV1 KIT NAME
Name of option Remark
Btu/hr 9,200 (4,100-10,500) 12,500 (4,600-14,000) FAQ100CVEA
Rated Cooling Capacity (Min-Max) Drain-Up Kit K-KDU572EVE
W 2,700 (1,200-3,080) 3,660 (1,350-4,100)
Wireless Type Cooling Only BRC7EB519
Total Power (Min-Max) W 794 (338-1,230) 1,109 (432-1,270) Remote Controller
Wired Type1 BRC1C61
Total Current (Min-Max) A 4.22 (1.86-5.74) 4.69 (2.27-5.84) Navigation Remote Controller Wired Type1 BRC1E62
COP W/W 3.40 3.30 Remote Sensor (For Indoor Temperature) KRCS01-4B
Central Remote Controller2 DCS302CA61
Refrigerant Type R410A
Unified ON/OFF Controller2 DCS301BA61
Air Flow Rate (H/M/L) CFM 340/327/290 410/360/320
Schedule Timer2 DST301BA61
Power Source Indoor V/Ph/Hz 220-240/1/50 Intelligent Touch Controller2 DCS601C51
Indoor (H/M/L) dBA 35/32/26 37/34/29 Wiring Adaptor For Electrical Appendices3 KRP4AA51
Sound Pressure Level Installation Box For Adaptor PCB KRP4AA93
Outdoor dBA 48
Electrical Box With Earth Terminal (3 Blocks) KJB311AA
Dimension Indoor mm 261x905x411
Electrical Box With Earth Terminal (2 Blocks) KJB212AA
(H X W X D)
Outdoor mm 550x765x285 Noise Filter (For Electromagnetic Interface Use Only) KEK26-1A
Indoor kg 21 Note: 1Wiring for wired remote controller to be procured locally.
Unit Weight 2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
Outdoor kg 31 33 3
Installation box for adaptor PCB (KRP4AA93) is necessary.
Outdoor Coil Type Cross Fin Coil
Liquid mm/in 6.35 / 1/4
Copper Pipe Size
Gas mm/in 9.52 / 3/8 12.7 / 1/2
Max. Interunit Piping Length m 15
Max. Installation Level Difference m 10
CEILING CASSETTE
KIT NAME
Heat Insulation Both liquid and gas piping Name Of Option Remark
FCQ50KAVEA FCQ60KAVEA FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEA
1. DUE TO PRODUCT INNOVATION, ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. Decoration Panel BYCP125K-W1
2. ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARD ISO13253. Sealing Material Of Air Discharge Outlet KDBH55K160F
3. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW:
Panel Spacer KDBP55H160FA
COOLING 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR.
4. SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, Chamber Without T-Duct Joint KDDP55B160
Fresh Air
THE SOUND PRESSURE LEVEL WILL BE HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION. Type With T-Duct Joint KDDP55B160K
Intake Kit1
5. CAPACITY (hp) AND (kW) ARE FOR EASE OF REFERENCE ONLY. Direct Installation Type KDDP55X160
High-efficiency Filter Unit (Colorimetric Method 65%) KAFP556B80 KAFP556B160
(Including Filter Chamber) (Colorimetric Method 90%) KAFP557B80 KAFP557B160
Replacement (Colorimetric Method 65%) KAFP552B80 KAFP552B160
High-Efficiency Filter (Colorimetric Method 90%) KAFP553B80 KAFP553B160
Filter Chamber KDDFP55B160

CEILING CONCEALED Replacement Long-Life Filter


Ultra Long-Life Filter Unit (Including Filter Chamber)
KAFP551K160
KAFP55B160
hp4 2.0 2.5 3.0 4.0 5.0 6.0 4.0 5.0 6.0 Replacement Ultra Long-Life Filter KAFP55H160H
Capacity
kW4 50 60 71 100 125 140 100 125 140 Branch Duct Chamber KDJP55B80 KDJP55B160
Indoor FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE FBQ100EVE FBQ125EVE FBQ140EVE Chamber Connection Kit2 KKSJ55KA160
Model
Outdoor RZR50MVM RZR60MVM RZR71MVM RZR100MVM RZR125MVM RZR140MVM RZR100MYM RZR125MYM RZR140MYM Insulation Kit For High Humidity KDTP55K80 KDTP55K160
17,100 20,5000 24,200 34,100 42,700 47,800 34,100 42,700 47,800 Wireless Type Cooling Only BRC7F635F
Btu/hr Remote Controller
Rated Cooling Capacity (Min-Max) (7,900-19,100) (8,900-21,500) (10,900-27,300) (17,100-38,200) (19,500-47,800) (21,200-52,600) (17,100-38,200) (19,500-47,800) (21,200-52,600) Wired Type3 BRC1C61
kW 5.0 (2.3-5.6) 6.0 (2.6-6.3) 7.1 (3.2-8.0) 10.0 (5.0-11.2)
12.5 (5.7-14.0) 14.0 (6.2-15.4) 10.0 (5.0-11.2) 12.5 (5.7-14.0) 14.0 (6.2-15.4) Navigation Remote Controller Wired Type3 BRC1E62
Power Consumption kW 1.39 1.69 2.22 2.82 4.58 5.85 2.82 4.58 5.85 Central Remote Controller4 DCS302CA61
Unified ON/OFF Controller4 DCS301BA61
Running Current, 1[3] A 6.71 8.16 10.72 13.62 22.13 28.26 [4.52] [7.35] [9.38]
Schedule Timer4 DST301BA61
COP W/W 3.60 3.56 3.20 3.55 2.73 2.39 3.55 2.73 2.39
intelligent Touch Controller4 DCS601C51
CSPF Wh/Wh 5.40 5.20 5.04 4.73 4.61 4.38 4.73 4.61 4.38
Adaptor For Wiring5 KRP1C63
Refrigerant Type R410A
Wiring Adaptor For Electrical Appendices(2)5 KRP4AA53
Air Flow Rate (H/M/L) CFM 635/530/441 812/688/565 1,130/953/794 1,271/1,077/883 1,130/953/794 1,271/1,077/883
Installation Box For Adaptor PCB KRP1H98
External Static Pressure Pa Rated 50 (50-150) Remote Sensor (For Indoor Temperature) KRCS01-4B
Indooor V/Ph/Hz 220-240/1/50
Power Source Note: 1Refer to page 20 for the details.
Outdoor V/Ph/Hz 220-240/1/50 380-415/3/50 2
Required for installing high-efficiency filter unit and ultra long-life filter unit.
Indoor (H/M/L) dBA 35/33/31 38/35/33 38/35.5/33 40/37.5/35 38/35.5/33 40/37.5/35 3
Wiring for wired remote controller to be procured locally.
Sound Pressure Level 4
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
Outdoor dBA 48 49 52 54 49 52 54 5
Installation box for adaptor PCB (KRP1H98) is necessary.
Dimension Indoor mm 245x1,000x800 245x1,400x800
(H X W X D) Outdoor mm 595x845x300 990x940x320
Indoor kg 37 47
Unit Weight
Outdoor kg 43 65 73
Outdoor Coil Type Hydrophilic Cross Fin Coil Micro Channel
Liquid mm/in 9.52 / 3/8
Copper Pipe Size
Gas mm/in 15.88 / 5/8
Max. Interunit Piping Length m 50 (Equivalent length 70)
Max. Installation Level Difference m 30
Heat Insulation Both liquid and gas piping
1. DUE TO PRODUCT INNOVATION, ALL SPECIFICATION ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2. NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW:
COOLING 27C DB / 19C WB INDOOR AND 35C DB / 24C WB OUTDOOR.
3. SOUND PRESSURE LEVELS ARE MEASURED IN SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION,
THE SOUND PRESSURE LEVEL WILL BE HIGHER AS A RESULT OF ROOM SPECIFICATION CONDITION.
4. CAPACITY (hp) AND (kW) ARE FOR EASE OF REFERENCE ONLY.
43 OPTIONS OPTIONS 44

Round Flow Type: List Of Optional Parts Required To Achieve Different Flow Patterns CEILING CONCEALED
For each flow pattern all round, 4-way, 3-way, 2-way, branch duct connection the compatibility of each independently installed option KIT NAME
Name of option Remark
(shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect. FBQ50EVE FBQ60EVE FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVE
A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation. 65% KAFP632B80 KAFP632B160
High-efficiency Filter 1
90% KAFP633B80 KAFP633B160
ALL ROUND FLOW 4-WAY FLOW Filter Chamber(For Rear Suction)1 KDDFP63B80 KDDFP63B160
Optional accessory parts Wireless Fresh Air Intake Kit Fresh Air Intake Kit Insulation Kit High-efficiency Ultra-long-life Long-life Filter1 KAFP631B80 KAFP631B160
Panel Spacer1 White KTBJ25K80W KTBJ25K160W
Independently installable optional parts Remote Controller (Chamber Type)1,2 (Direct Installation Type) For High Humidity Filter Unit2 Filter Unit2
Panel/grille Related Panel Spacer1 o o o x o o Service Panel Fresh White KTBJ25K80F KTBJ25K160F
Brown KTBJ25K80T KTBJ25K160T
Operation Control Related Wireless Remote Controller o o o o o o Air Discharge Adaptor KDAP25A71A KDAP25A140A
Fresh Air Intake Kit (Chamber Type)1,2 o o x x o o Shield Plate For Side Plate KDBD63A160
Auxillary Function Related Fresh Air Intake Kit (Direct Installation Type) o o x o o o Remote Controller Wireless Type Cooling Only BRC4C66
Insulation Kit For High Humidity x o x o x x Wired Type2 BRC1C61
High-efficiency Filter Unit2 o o o o x x Navigation Remote Controller Wired Type2 BRC1E62
Filter Related
Ultra-long-life Filter Unit2 o o o o x x Adaptor For Wiring KRP1C64
Wiring Adaptor For Electrical Appendices(2) KRP4AA51
Remote Sensor KRCS01-4B
3-WAY FLOW 2-WAY FLOW Mounting Plate For Adaptor PCB.3,4,5 KRP4A98
Optional Accessory Parts Wireless Fresh Air Intake Kit Fresh Air Intake Kit Insulation Kit High-efficiency Ultra-long-life Central Remote Controller6 DCS302CA61
Panel Spacer1
Independently Installable Optional Parts Remote Controller (Chamber Type)1,2 (Direct Installation Type) For High Humidity Filter Unit2 Filter Unit2 Unified ON/OFF Controller6 DCS301BA61
Panel/grille Related Panel Spacer1 o3 o3 o3 x x o3 Schedule Timer6 DST301BA61
Operation Control Related Wireless Remote Controller o3 o o o x o Intelligent Touch Controller6 DCS601C51
Fresh Air Intake Kit (Chamber Type)1,2 o3 o x x x o Note: 1If installing high efficiency filter and long-life filter to the unit, filter chamber is required. Up to 2 adaptors can be fixed for each mounting plate.
4

Auxillary Function Related Fresh Air Intake Kit (Direct Installation Type) o3 o x o x o 2
Wiring for wired remote controller to be procured locally. Only one mounting plate can be installed for each indoor unit.
5
3
Mounting plate is necessary for each adaptor marked . The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.
6

Insulation Kit For High Humidity x o x o x x


Filter Related Ultra-long-life Filter Unit2 o3 o o o x x
BRANCH DUCT CONNECTION
Optional Accessory Parts
Independently Installable Optional Parts
Panel Spacer1
Wireless Fresh Air Intake Kit Fresh Air Intake Kit Insulation Kit
Remote Controller (Chamber Type)1,2 (Direct Installation Type) For High Humidity
High-efficiency Ultra-long-life
Filter Unit2 Filter Unit2 OUTDOOR UNIT
Branch Duct Chamber 1
1-way Branch / Unit 3-way Flow o o o o 4 x x o
(Round Duct Type) 2-way Branch / Unit 2-way Flow x o o o 4 x x o
1-way Branch / Unit 2-way Flow x o o o 4 x x o KIT NAME
Note: 1In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. RZR50MVM RZR100MVM RZR100MYM
Name Of Option
Before starting installation work make sure to check whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable. RZR60MVM RZR125MVM RZR125MYM
2
Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position. RZR71MVM RZR140MVM RZR140MYM
3
It is not possible to use panel spacers in a 2-way flow installation.
4
It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed. Central Drain Plug KKP014A4 KKPJ5G280
Fixture For Preventing Overturning ---------- KKTP5B112
Wire Fixture For Preventing Overturning ----------
Demand Adaptor ---------- KRP58M51+EKMKSA1 KRP58M51

CEILING EXPOSED
KIT NAME
Name Of Option Remark
FHQ50DAVMA FHQ60DAVMA FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA
Replacement Long-life Filter Resin Net KAFP501A56 KAFP501A80 KAFP501A160
Fresh Air Intake Kit KDDQ50A140
Drain Pump Kit KDU50P140VE
L-type Piping Kit (For Upward Direction) KHFP5N160
Wireless Type Cooling Only BRC7GA56
Remote Controller
Wired Type1 BRC1C61
Navigation Remote Controller Wired Type1 BRC1E62
Central Remote Controller DCS302CA61
Unified ON/OFF Controller DCS301BA61
Schedule Timer DST301BA61
Intelligent Touch Controller2 DCS601C51
Wiring Adaptor For Electrical Appendices KRP1BA54
Wiring Adaptor For Electrical Appendices3 KRP4AA52
Installation Box For Adaptor Pcb KRP1D93A
Adaptor Box Mounting Plate KKSAP50A56 ----------
Remote Sensor (For Indoor Temperature) KRCS01-4B
Electrical Box With Earth Terminal (3 Blocks) KJB311AA
Electrical Box With Earth Terminal (2 Blocks) KJB212AA
Note: 1Wiring for wired remote controller to be procured locally.
2
The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.