11-15. GENERAL. Aircraft batteries may 1.4 and 1.5 volts per cell are generally used. In
be used for many functions, e.g., ground all cases, follow the recommendations of the
power, emergency power, improving DC bus battery manufacturer.
stability, and fault-clearing. Most small pri-
vate aircraft use lead-acid batteries. Most 11-17. BATTERY FREEZING. Discharged
commercial and military aircraft use NiCad lead-acid batteries exposed to cold tempera-
batteries. However, other types are becoming tures are subject to plate damage due to freez-
available such as gel cell and sealed lead-acid ing of the electrolyte. To prevent freezing
batteries. The battery best suited for a par- damage, maintain each cells specific gravity
ticular application will depend on the relative at 1.275, or for sealed lead-acid batteries check
importance of several characteristics, such as open circuit voltage. (See table 11-1.) Ni-
weight, cost, volume, service or shelf life, dis- Cad battery electrolyte is not as susceptible to
charge rate, maintenance, and charging rate. freezing because no appreciable chemical
Any change of battery type may be considered change takes place between the charged and
a major alteration. discharged states. However, the electrolyte
will freeze at approximately minus 75 F.
a. Storage batteries are usually identified
by the material used for the plates. All battery NOTE: Only a load check will deter-
types possess different characteristics and, mine overall battery condition.
therefore, must be maintained in accordance
with the manufacturers recommendations.. TABLE 11-1. Lead-acid battery electrolyte freezing
points.
State of Charge (SOC) for sealed
WARNING: It is extremely danger- Specific Freeze point lead-acid batteries at 70
ous to store or service lead-acid and Gravity C. F. SOC 12 volt 24 volt
1.300 -70 -95 100% 12.9 25.8
NiCad batteries in the same area. In- 1.275 -62 -80 75% 12.7 25.4
troduction of acid electrolytes into al- 1.250 -52 -62 50% 12.4 24.8
1.225 -37 -35 25% 12.0 24.0
kaline electrolyte will destroy the Ni- 1.200 -26 -16
Cad and vice-versa. 1.175 -20 -4
1.150 -15 +5
1.125 -10 +13
11-16. BATTERY CHARGING. Operation 1.100 -8 +19
e. Battery and Charger Characteristics. weakening of a cell. After replacing the bad
The following information is provided to ac- cell with a good cell, the batterys life can be
quaint the user with characteristics of the more extended for five or more years. Full dis-
common aircraft battery and battery charger charge is not harmful to this type of battery.
types. Products may vary from these descrip-
tions due to different applications of available (6) NiCad sealed batteries are similar in
technology. Consult the manufacturer for spe- most respects to NiCad vented batteries, but do
cific performance data. not normally require the addition of water.
Fully discharging the battery (to zero volts)
NOTE: Under no circumstances con- may cause irreversible damage to one or more
nect a lead-acid battery to a charger, cells, leading to eventual battery failure due to
unless properly serviced. low capacity.
(1) Lead-acid vented batteries have a (7) The state of charge of a NiCad bat-
two volt nominal cell voltage. Batteries are tery cannot be determined by measuring the
constructed so that individual cells cannot be specific gravity of the potassium hydroxide
removed. Occasional addition of water is re- electrolyte. The electrolyte specific gravity
quired to replace water loss due to overcharg- does not change with the state of charge. The
ing in normal service. Batteries that become only accurate way to determine the state of
fully discharged may not accept recharge. charge of a NiCad battery is by a measured
discharge with a NiCad battery charger and
(2) Lead-acid sealed batteries are simi- following the manufacturers instructions.
lar in most respects to lead-acid vented batter- After the battery has been fully charged and
ies, but do not require the addition of water. allowed to stand for at least two hours, the
fluid level may be adjusted, if necessary, using
(3) The lead-acid battery is economical distilled or demineralized water. Because the
and has extensive application, but is heavier fluid level varies with the state of charge, wa-
than an equivalent performance battery of an- ter should never be added while the battery is
other type. The battery is capable of a high installed in the aircraft. Overfilling the battery
rate of discharge and low temperature per- will result in electrolyte spewage during
formance. However, maintaining a high rate charging. This will cause corrosive effects on
of discharge for a period of time usually warps the cell links, self-discharge of the battery, di-
the cell plates, shorting out the battery. Its lution of the electrolyte density, possible
electrolyte has a moderate specific gravity, and blockage of the cell vents, and eventual cell
state of charge can be checked with a hy- rupture.
drometer.
(8) Lead-acid batteries are usually
(4) Do not use high amperage automo- charged by regulated DC voltage sources. This
tive battery chargers to charge aircraft allows maximum accumulation of charge in
batteries. the early part of recharging.
having a shorted cell might overheat due to ex- g. Aircraft Battery Inspection.
cessive overcharge and undergo a thermal run-
away, destroying the battery and creating a (1) Inspect battery sump jar and lines
possible safety hazard to the aircraft. for condition and security.
DEFINITION: Thermal runaway can (2) Inspect battery terminals and quick-
result in a chemical fire and/or explo- disconnect plugs and pins for evidence of cor-
sion of the NiCad battery under re- rosion, pitting, arcing, and burns. Clean as re-
charge by a constant-voltage source, quired.
and is due to cyclical, ever-increasing
temperature and charging current. (3) Inspect battery drain and vent lines
One or more shorted cells or an exist- for restriction, deterioration, and security.
ing high temperature and low charge
can produce the cyclical sequence of (4) Routine pre-flight and post-flight
events: (1) excessive current, inspection procedures should include observa-
(2) increased temperature, tion for evidence of physical damage, loose
(3) decreased cell(s) resistance, connections, and electrolyte loss.
(4) further increased current, and
(5) further increased temperature. 11-20. ELECTROLYTE SPILLAGE.
This will not become a self-sustaining Spillage or leakage of electrolyte may result in
thermal-chemical action if the con- serious corrosion of the nearby structure or
stant-voltage charging source is re- control elements as both sulfuric acid and po-
moved before the battery temperature tassium hydroxide are actively corrosive.
is in excess of 160 F. Electrolyte may be spilled during ground
servicing, leaked when cell case rupture oc-
(10) Pulsed-current battery chargers are curs, or sprayed from cell vents due to exces-
sometimes provided for NiCad batteries. sive charging rates. If the battery is not case
enclosed, properly treat structural parts near
CAUTION: It is important to use the the battery that may be affected by acid fumes.
proper charging procedures for bat- Treat all case and drain surfaces, that have
teries under test and maintenance. been affected by electrolyte, with a solution of
These charging regimes for recondi- sodium bicarbonate (for acid electrolyte) or
tioning and charging cycles are de- boric acid, vinegar, or a 3 percent solution of
fined by the aircraft manufacturer acetic acid (for potassium hydroxide
and should be closely followed. electrolyte).
11-30. GENERAL. When installing equip- ode. The best protection against diode destruction
ment which consumes electrical power in an by voltage surges is to make certain that the bat-
aircraft, it should be determined that the total tery is never disconnected from the aircraft's
electrical load can be safely controlled or man- electrical system when the alternator is in op-
aged within the rated limits of the affected eration. The battery acts as a large capacitor
components of the aircrafts electrical power and tends to damp out voltage surges. The
supply system. Addition of most electrical battery must never be connected with reversed
utilization equipment is a major alteration and polarity as this may subject the diodes to a
requires appropriate FAA approval. The elec- forward bias condition, allowing very high cur-
trical load analysis must be prepared in general rent conduction that will generally destroy
accordance with good engineering practices. them instantly.
Additionally, an addendum to the flight man-
ual is generally required. 11-34.
STATIC ELECTRICAL POWER
CONVERTERS. Static power converters em-
11-31. INSTALLATION CLEARANCE ploy solid-state devices to convert the aircrafts
PROVISIONS. All electrical equipment primary electrical source voltage to a different
should be installed so that inspection and voltage or frequency for the operation of radio
maintenance may be performed and that the in- and electronic equipment. They contain no
stallation does not interfere with other systems, moving parts (with the exception of a cooling
such as engine or flight controls. fan on some models) and are relatively main-
tenance free. Various types are available for ac
11-32. WIRES, WIRE BUNDLES, AND to dc or dc to ac conversion.
CIRCUIT PROTECTIVE DEVICES. Be-
fore any aircraft electrical load is increased, the a. Location of static converters should
new total electrical load (previous maximum be carefully chosen to ensure adequate venti-
load plus added load) must be checked to de- lation for cooling purposes. Heat-radiating fins
termine if the design levels are being ex- should be kept clean of dirt and other foreign
ceeded. Where necessary, wires, wire bundles, matter that may impair their cooling proper-
and circuit protective devices having the cor- ties.
rect ratings should be added or replaced.
b. Static power converters often emit un-
11-33. ALTERNATOR DIODES. Alter- acceptable levels of EMI that may disrupt
nators employ diodes for the purpose of con- communication equipment and navigation in-
verting the alternating current to direct current. struments. Properly shielded connectors, ter-
These diodes are solid-state electronic devices minal blocks, and wires may be required, with
and are easily damaged by rough handling, all shields well grounded to the airframe.
abuse, over heating, or reversing the battery
connections. A voltage surge in the line, if it CAUTION: Do not load convert-
exceeds the design value, may destroy the di- ers beyond their rated capacity.
data should provide a true picture of the status c. Wiring. Junction box layouts should
of the electrical system. New or additional take into consideration the necessity for ade-
electrical devices should not be installed in an quate wiring space and possible future addi-
aircraft, nor the capacity changed of any power tions. Electrical wire bundles should be laced
source, until the status of the electrical system or clamped inside the box so that cables do not
in the aircraft has been determined accurately touch other components, prevent ready access,
and found not to adversely affect the integrity or obscure markings or labels. Cables at en-
of the electrical system. trance openings should be protected against
chafing by using grommets or other suitable
11-37. JUNCTION BOX CONSTRUC- means.
TION. Replacement junction boxes should be
fabricated using the same material as the origi- 11-46. [RESERVED.]
11-38.
nal or from a fire-resistant, nonabsorbent mate-
rial, such as aluminum, or an acceptable plastic
material. Where fire-proofing is necessary, a
stainless steel junction box is recommended.
Rigid construction will prevent oil-canning
of the box sides that could result in internal
short circuits. In all cases, drain holes should
be provided in the lowest portion of the box.
Cases of electrical power equipment must be
insulated from metallic structure to avoid
ground fault related fires. (See para-
graph 11-7.)
11-47. GENERAL. All electrical wires TABLE 11-3. DC wire and circuit protector chart.
must be provided with some means of circuit Wire AN gauge
copper Circuit breaker amp. Fuse amp.
protection. Electrical wire should be protected
22 5 5
with circuit breakers or fuses located as close 20 7.5 5
as possible to the electrical power source bus. 18 10 10
Normally, the manufacturer of electrical 16 15 10
14 20 15
equipment will specify the fuse or breaker to 12 30 20
be used when installing the respective equip- 10 40 30
ment, or SAE publication, ARP 1199, may be 8 50 50
6 80 70
referred to for recommended practices.
4 100 70
2 125 100
11-48. DETERMINATION OF CIRCUIT 1 150
BREAKER RATINGS. Circuit protection 0 150
devices must be sized to supply open circuit Basis of chart:
(1) Wire bundles in 135 F. ambient and altitudes up to
capability. A circuit breaker must be rated so 30,000 feet.
that it will open before the current rating of the (2) Wire bundles of 15 or more wires, with wires carrying
no more than 20 percent of the total current carrying
wire attached to it is exceeded, or before the capacity of the bundle as given in Specification
cumulative rating of all loads connected to it MIL-W-5088 (ASG).
(3) Protectors in 75 to 85 F. ambient.
are exceeded, whichever is lowest. A circuit (4) Copper wire Specification MIL-W-5088.
breaker must always open before any compo- (5) Circuit breakers to Specification MIL-C-5809 or
equivalent.
nent downstream can overheat and generate (6) Fuses to Specification MIL-F-15160 or equivalent.
smoke or fire. Wires must be sized to carry
continuous current in excess of the circuit
protective device rating, including its time- 11-50. RESETTABLE CIRCUIT PRO-
current characteristics, and to avoid excessive TECTION DEVICES.
voltage drop. Refer to section 5 for wire rating
methods. a. All resettable type circuit breakers
must open the circuit irrespective of the posi-
11-49. DC CIRCUIT PROTECTOR tion of the operating control when an overload
CHART. Table 11-3 may be used as a guide or circuit fault exists. Such circuit breakers are
for the selection of circuit breaker and fuse referred to as trip free.
rating to protect copper conductor wire. This
chart was prepared for the conditions speci- b. Automatic reset circuit breakers, that
fied. If actual conditions deviate materially automatically reset themselves periodically, are
from those stated, ratings above or below the not recommended as circuit protection devices
values recommended may be justified. For ex- for aircraft.
ample, a wire run individually in the open air
may possibly be protected by the circuit 11-51. CIRCUIT BREAKER USAGE.
breaker of the next higher rating to that shown Circuit breakers are designed as circuit protec-
on the chart. In general, the chart is conserva- tion for the wire (see paragraph 11-48
tive for all ordinary aircraft electri- and 11-49), not for protection of black boxes
cal installations.
armature and field coils is released when the g. Low Energy Loads. Switches rated
control switch is opened. for use at 28 VDC or more, and at 1.0 amp or
more, generally have silver contacts. In gen-
e. Switch Selection. Switches for aircraft eral, silver contacts should not be used to con-
use should be selected with extreme caution. trol devices which have either a voltage less
The contact ratings should be adequate for all than 8 volts or a continuous current less than
load conditions and applicable voltages, at 0.5 amps unless the switch is specifically rated
both sea level and the operational altitude. for use with low-energy loads. Table 11-5
Consideration should be given to the variation provides general guidelines for selecting con-
in the electrical power characteristics, using tact materials for low-energy loads, but is not
MIL-STD-704 as a guide. applicable to hermetically sealed switches.
f. Derating Factors. Table 11-4 provides (1) Typical logic load devices have a
an approximate method for derating nominal voltage of 0.5 volts to 28 volts and a continu-
ratings to obtain reasonable switch efficiency ous current of less than 0.5 amps. A suitable
and service life under reactive load conditions. method of rating switches for use on logic load
devices is specified in ANSI/EIA 5200000.
WARNING: Do not use AC derated (General specification for special use electro-
switches in DC circuits. AC switches mechanical switches of certified quality.)
will not carry the same amperage as a
DC switch. TABLE 11-5. Selection of contact material.
28 VDC Lamp 8
28 VDC Motor 3
12 VDC Lamp 5
12 VDC Motor 2
NOTES:
NOTES: 1. If sulfide, moisture, or any form of contamination is
present, a sealed switch should be used. The degree
1. To find the nominal rating of a switch required to operate of sealing required (environmental or hermetic) is de-
a given device, multiply the continuous current rating pendent upon the environment in which the switch is
of the device by the derating factor corresponding intended to be operated.
to the voltage and type of load.
2. If particle contamination in any form is likely to reach
2. To find the continuous rating that a switch of a the contacts, bifurcated contacts should be used.
given nominal rating will handle efficiently,
divide the switch nominal rating by the derating 3. Low-voltage high-current loads are difficult to predict
factor corresponding to the voltage and type of load. and may result in a combined tendency of noncontact,
sticking, and material transfer.
(2) Typical low-level load devices have (2) The arcing of electromechanical
a voltage of less than 0.5 volts and a continu- switch contacts generates short duration
ous current of less than 0.5 amps. A suitable EMI/RFI when controlling highly inductive
method of rating switches for use on logic load electrical loads. Twisting lead wires, metal
devices is specified in ANSI/EIA 5200000. overbraids, and lead wire routing can reduce or
eliminate generation problems when dealing
h. Shock and Vibration. with arcing loads. Proximity sensors generally
use a relatively low-energy electromagnetic
(1) Electromechanical switches (toggle field to sense the target. Adequate spacing is
switches) are most susceptible to shock and required to prevent interference between adja-
vibration in the plane that is parallel to contact cent proximity sensors or other devices sus-
motion. Under these conditions the switch ceptible to EMI/RFI. Refer to manufacturers
contacts may momentarily separate. instructions.
ANSI/EIA 5200000 specifies that contact
separations greater than 10 microseconds and b. Temperature.
that closing of open contacts in excess of
1 microsecond are failures. Repeated contact (1) Electromechanical switches can
separations during high levels of vibration or withstand wide temperature ranges and rapid
shock may cause excessive electrical degrada- gradient shifts without damage. Most aircraft
tion of the contacts. These separations can switches operate between -55 C and 85 C
also cause false signals to be registered by with designs available from -185 C to 260 C
electronic data processors without proper buff- or more. Higher temperatures require more
ering. exotic materials, which can increase costs and
limit life. It should be noted that o-ring seals
(2) Although proximity switches do not and elastomer boot seals tend to stiffen in ex-
have moving parts, the reliability of the inter- treme cold. This can increase operating forces
nal electronic parts of the switch may be re- and reduce release forces or stop the switch
duced. Reliability and mean time between- from releasing.
failure (MTBF) calculations should reflect the
applicable environment. Note that the mount- (2) Proximity sensors are normally de-
ing of both the proximity sensor and its target signed for environments from -55 C to
must be rigid enough to withstand shock or vi- 125 C. During temperature excursions, the
bration to avoid creating false responses. operating and release points may shift from
5 percent to 10 percent. Reliability of the
i. Electromagnetic/Radio Frequency In- proximity sensor will typically be highest at
terference (EMI/RFI). room temperature. The reliability and MTBF
estimates should be reduced for use under high
(1) DC operated electromechanical temperatures or high thermal gradients.
switches are usually not susceptible to
EMI/RFI. Proximity switches are susceptible c. Sealing.
to an EMI/RFI environment and must be
evaluated in the application. Twisting lead NOTE: The materials used for sealing
wires, metal overbraids, lead wire routing, and (o-rings, potting materials, etc.)
the design of the proximity switch can mini- should be compatible with any air-
mize susceptibility. craft fluids to which the switch may be
exposed.
(1) Electromechanical switches range in a. Use of Relays. Most relays are used as
sealing from partially sealed to hermetically a switching device where a weight reduction
sealed. Use a sealed switch when the switch can be achieved, or to simplify electrical con-
will be exposed to a dirty environment during trols. It should be remembered that the relay is
storage, assembly, or operation. Use a higher an electrically operated switch, and therefore
level of sealing when the switch will not have subject to dropout under low system voltage
an arcing load to self-clean the contacts. Low- conditions.
energy loads tend to be more susceptible to
contamination. b. Types of Connections. Relays are
manufactured with various connective means
(2) Proximity switches for aircraft ap- from mechanical to plug-in devices. Installa-
plications typically have a metal face and pot- tion procedures vary by the type of connection
ting material surrounding any electronics and and should be followed to ensure proper op-
lead wire exits. The potting material should be eration of the relay.
compatible with the fluids the switch will be
exposed to in the environment. The plastic c. Repair. Relays are complicated elec-
sensing face of some proximity switches may tromechanical assemblies and most are not re-
be subject to absorption of water that may pairable.
cause the operating point to shift should be
protected. d. Relay Selection.
11-65. [RESERVED.]
11-57.
11-66. GENERAL. Wires must be sized so TABLE 11-6. Tabulation chart (allowable voltage drop
that they: have sufficient mechanical strength between bus and utilization equipment ground).
to allow for service conditions; do not exceed Nominal Allowable voltage
system drop continuous Intermittent
allowable voltage drop levels; are protected by voltage operation operation
system circuit protection devices; and meet
circuit current carrying requirements.
14 0.5 1
28 1 2
a. Mechanical Strength of Wires. If it is 115 4 8
200 7 14
desirable to use wire sizes smaller than #20,
particular attention should be given to the me-
chanical strength and installation handling of bonding to the structure or a special electric
these wires, e.g., vibration, flexing, and termi- current return path has been provided that is
nation. Wire containing less than 19 strands capable of carrying the required electric cur-
must not be used. Consideration should be rent with a negligible voltage drop. To deter-
given to the use of high-strength alloy con- mine circuit resistance check the voltage drop
ductors in small gauge wires to increase me- across the circuit. If the voltage drop does not
chanical strength. As a general practice, wires exceed the limit established by the aircraft or
smaller than size #20 should be provided with product manufacturer, the resistance value for
additional clamps and be grouped with at least the circuit may be considered satisfactory.
three other wires. They should also have ad- When checking a circuit, the input voltage
ditional support at terminations, such as con- should be maintained at a constant value. Ta-
nector grommets, strain relief clamps, shrink- bles 11-7 and 11-8 show formulas that may be
able sleeving, or telescoping bushings. They used to determine electrical resistance in wires
should not be used in applications where they and some typical examples.
will be subjected to excessive vibration, re-
peated bending, or frequent disconnection d. Resistance Calculation Methods.
from screw termination. Figures 11-2 and 11-3 provide a convenient
means of calculating maximum wire length for
b. Voltage Drop in Wires. The voltage the given circuit current.
drop in the main power wires from the genera-
tion source or the battery to the bus should not (1) Values in tables 11-7 and 11-8 are
exceed 2 percent of the regulated voltage when for tin-plated copper conductor wires. Be-
the generator is carrying rated current or the cause the resistance of tin-plated wire is
battery is being discharged at the 5-minute slightly higher than that of nickel or silver-
rate. The tabulation shown in table 11-6 de- plated wire, maximum run lengths determined
fines the maximum acceptable voltage drop in from these charts will be slightly less than the
the load circuits between the bus and the utili- allowable limits for nickel or silver-plated
zation equipment ground. copper wire and are therefore safe to use. Fig-
ures 11-2 and 11-3 can be used to derive
c. Resistance. The resistance of the cur- slightly longer maximum run lengths for silver
rent return path through the aircraft structure is or nickel-plated wires by multiplying the
generally considered negligible. However, this maximum run length by the ratio of resistance
is based on the assumption that adequate of tin-plated wire, divided by the resistance of
silver or nickel-plated wire.
TABLE 11-7. Examples of determining required tin- (3) Voltage drop calculations for alumi-
plated copper wire size and checking voltage drop using num wires can be accomplished by multiplying
figure 11-2
the resistance for a given wire size, defined in
Check-
calculated volt-
table 11-10, by the wire run length and circuit
Wire Size age drop (VD)= current.
Run Circuit From (Resistance/Ft)
Voltage Lengths Current Chart (Length) (Cur-
drop (Feet) (Amps) rent) (4) When the estimated or measured
1 107 20 No. 6 VD= (.00044
ohms/ft)
conductor temperature (T2) exceeds 20 C,
(107)(20)= such as in areas having elevated ambient tem-
0.942
0.5 VD= (.00028
peratures or in fully loaded power-feed wires,
90 20 No. 4
ohms/ft) the maximum allowable run length (L2), must
(90)(20)=
0.504 be shortened from L1 (the 20 C value) using
4 88 20 No. 12 VD= (.00202 the following formula for copper conductor
ohms/ft)
(88)(20)= wire:
3.60
7 100 20 No. 14 VD= (.00306
(254.5 C )( L1)
ohms/ft) L2 =
(100)(20)= (234.5 C )+ )(T 2)
6.12
TABLE 11-8. Examples of determining maximum tin- For aluminum conductor wire, the formula is:
plated copper wire length and checking voltage drop
using figure 11-2. (258.1 C )( L1)
L2 =
Check-calculated (238.1 C ) + (T 2)
voltage drop
Maximum (VD)= (Resis-
Maximum Circuit Wire Run tance/Ft) (Length) These formulas use the reciprocal of each ma-
Voltage Wire Current Length (Current) terials resistively temperature coefficient to
drop Size (Amps) (Feet)
VD= (.00126 take into account increased conductor resis-
1 No. 10 20 39
ohms/ft) tance resulting from operation at elevated tem-
(39)(20)= .98
0.5 VD= (.00126 peratures.
---- 19.5
ohms/ft)
(19.5)(20)= (5) To determine T2 for wires carrying a
.366
4 ---- 156 VD= (.00126 high percentage of their current carrying capa-
ohms/ft) bility at elevated temperatures, laboratory
(156)(20)=
3.93 testing using a load bank and a high-
7 ---- 273 VD= (.00126 temperature chamber is recommended. Such
ohms/ft)
(273)(20)= tests should be run at anticipated worse case
6.88 ambient temperature and maximum current-
loading combinations.
(2) As an alternative method or a means
of checking results from figure 11-2, continu- (6) Approximate T2 can be estimated
ous flow resistance for a given wire size can be using the following formula:
read from table 11-9 and multiplied by the wire
run length and the circuit current. For inter- T2 = T1 + (TR T1 )( I 2 / I max )
mittent flow, use figure 11-3.
(1) The wire size should be sufficient to (4) The circuit has continuous opera-
prevent an excessive voltage drop while car- tion.
rying the required current over the required
distance. (See table 11-6, Tabulation Chart, for (5) Estimated conductor temperature is
allowable voltage drops.) 20 C or less.
(2) The size should be sufficient to pre- The scale on the left of the chart represents
vent overheating of the wire carrying the re- maximum wire length in feet to prevent an ex-
quired current. (See paragraph 11-69 for al- cessive voltage drop for a specified voltage
lowable current carrying calculation methods.) source system (e.g., 14V, 28V, 115V, 200V).
This voltage is identified at the top of scale
b. Two Requirements. To meet the two and the corresponding voltage drop limit for
requirements (see paragraph 11-66b) in se- continuous operation at the bottom. The scale
lecting the correct wire size using figure 11-2 (slant lines) on top of the chart represents am-
or figure 11-3, the following must be known: peres. The scale at the bottom of the chart rep-
resents wire gauge.
(1) The wire length in feet.
STEP 1: From the left scale find the wire
(2) The number of amperes of current to length, 50 feet under the 28V source column.
be carried.
STEP 2: Follow the corresponding horizontal
(3) The allowable voltage drop line to the right until it intersects the slanted
permitted. line for the 20-amp load.
(4) The required continuous or inter- STEP 3: At this point, drop vertically to the
mittent current. bottom of the chart. The value falls between
No. 8 and No. 10. Select the next larger size
(5) The estimated or measured con- wire to the right, in this case No. 8. This is the
ductor temperature. smallest size wire that can be used without ex-
ceeding the voltage drop limit expressed at the
(6) Is the wire to be installed in conduit bottom of the left scale. This example is plot-
and/or bundle? ted on the wire chart, figure 11-2. Use figure
11-2 for continuous flow and figure 11-3 for
(7) Is the wire to be installed as a single intermittent flow.
wire in free air?
d. Procedures in Example No. 1 para-
c. Example No. 1. Find the wire size in graph 11-68c, can be used to find the wire size
figure 11-2 using the following known infor- for any continuous or intermittent operation
mation: (maximum two minutes). Voltage (e.g.
14 volts, 28 volts, 115 volts, 200 volts) as in-
(1) The wire run is 50 feet long, in- dicated on the left scale of the wire chart in
cluding the ground wire. figure 11-2 and 11-3.
(2) Current load is 20 amps. e. Example No. 2. Using figure 11-2, find
(3) The voltage source is 28 volts from the wire size required to meet the allowable
bus to equipment. voltage drop in table 11-6 for a wire carrying
(3) The voltage source is 28 volts. (5) Use figure 11-6, find the derate
factor for 8 wires in a bundle at 60 percent.
(4) The wire type used has a 200 C First find the number of wires in the bundle (8)
conductor rating and it is intended to use this at bottom of graph and intersect with the
thermal rating to minimize the wire gauge. 60 percent curve meet. Read derating factor,
Assume that the method described in para- (left side of graph) which is 0.6. Multiply
graph 11-66d(6) was used and the minimum 0.6 x 42.77 Amps = 26 Amps.
wire size to carry the required current is #14.
Imax = 26 amps (this is the maximum
(5) Ambient temperature is 50 C under current the #14 gauge wire could carry at 50C
hottest operating conditions. ambient
f. Procedures in example No. 2. L1=15.5 feet maximum run length for size
#14 wire carrying 20 amps from figure 11-2
STEP 1: Assuming that the recommended
load bank testing described in para- STEP 2: From paragraph 11-66d (5) and (6),
graph 11-66d(5) is unable to be conducted, determine the T2 and the resultant maximum
then the estimated calculation methods out- wire length when the increased resistance of
lined in paragraph 11-66d(6) may be used to the higher temperature conductor is taken into
determine the estimated maximum current account.
(Imax). The #14 gauge wire mentioned above
can carry the required current at 50 C ambient
(allowing for altitude and bundle derating).
(
T2 = T1 + ( TR T1 ) I 2 / I max )
(1) Use figure 11-4a to calculate the T2 = 50 C + (200 C 50 C )( 20 A / 26 A
Imax a #14 gauge wire can carry. = 50 C+(150 C)(.877)
Where: T2 = 182 C
The size #14 wire selected using the methods (7/35 = 20 percent) will be carrying power cur-
outlined in paragraph 11-66d is too small to rents nearly at or up to capacity.
meet the voltage drop limits from figure 11-2
for a 15.5 feet long wire run. STEP 1: Refer to the single wire in free air
curves in figure 11-4a. Determine the change
STEP 3: Select the next larger wire (size #12) of temperature of the wire to determine free air
and repeat the calculations as follows: ratings. Since the wire will be in an ambient
of 60 C and rated at 200 C, the change of to
L1=24 feet maximum run length for temperature is 200 C - 60 C = 140 C. Fol-
12 gauge wire carrying 20 amps from fig- low the 140 C temperature difference hori-
ure 11-2. zontally until it intersects with wire size line
on figure 11-4a. The free air rating for
Imax = 37 amps (this is the maximum current size #20 is 21.5 amps, and the free air rating
the size #12 wire can carry at 50 C ambient. for size #22 is 16.2 amps.
Use calculation methods outlined in para-
graph 11-69 and figure 11-4a. STEP 2: Refer to the bundle derating curves
in figure 11-5, the 20 percent curve is selected
T2 = 50 o C + (200 o C - 50 o C) ( 20 A / 37 A = since circuit analysis indicate that 20 percent
50 o C + (150 o C)(-540) = 131 o C or less of the wire in the harness would be car-
rying power currents and less than 20 percent
254.5 o C(L1 )
L2 = of the bundle capacity would be used. Find
234.5 o C + (T2 ) 35 (on the abscissa) since there are 35 wires in
(254.5 o C)(24ft) 6108 the bundle and determine a derating factor of
L2 = o o
= 0.52 (on the ordinate) from the 20 percent
(234.5 C) + (131 C) 366
curve.
(254.5 o C)(24ft)
L2 = = 16.7 ft
366 STEP 3: Derate the size #22 free air rating by
The resultant maximum wire length, after ad- multiplying 16.2 by 0.52 to get 8.4 amps in-
justing downward for the added resistance as- harness rating. Derate the size #20 free air-
sociated with running the wire at a higher tem- rating by multiplying 21.5 by 0.52 to get
perature, is 15.4 feet, which will meet the 11.2 amps in-harness rating.
original 15.5 foot wire run length requirement
without exceeding the voltage drop limit ex- STEP 4: Refer to the altitude derating curve
pressed in figure 11-2. of figure 11-6, look for 60,000 feet (on the ab-
scissa) since that is the altitude at which the
11-69. COMPUTING CURRENT CARRY- vehicle will be operating. Note that the wire
ING CAPACITY. must be derated by a factor of 0.79 (found on
the ordinate). Derate the size
a. Example 1. Assume a harness (open or #22 harness rating by multiplying
braided), consisting of 10 wires, size #20, 8.4 amps by 0.79 to get 6.6 amps. Derate the
200 C rated copper and 25 wires, size #22, size #20 harness rating by multiplying
200 C rated copper, will be installed in an 11.2 amps by 0.79 to get 8.8 amps.
area where the ambient temperature is 60 C
and the vehicle is capable of operating at a STEP 5: To find the total harness capacity,
60,000-foot altitude. Circuit analysis reveals multiply the total number of size #22 wires by
that 7 of the 35 wires in the bundle the derated capacity (25 x 6.6 = 165.0 amps)
and add to that the number of size #20 wires
multiplied by the derated capacity selected because we know all 12 wires will be
(10 x 8.8 = 88 amps) and multiply the sum by carrying full load. Find 12 (on the abscissa)
the 20 percent harness capacity factor. Thus, since there are 12 wires in the bundle and de-
the total harness capacity is termine a derating factor of 0.43 (on the ordi-
(165.0 + 88.0) x 0.20 = 50.6 amps. It has been nate) from the 100 percent curve.
determined that the total harness current
should not exceed 50.6 A, size #22 wire should STEP 3: Derate the size #12 free air ratings by
not carry more than 6.6 amps and size multiplying 68 amps and 61 amps by 0.43 to
#20 wire should not carry more than 8.8 amps. get 29.2 amps and 26.2 amps, respectively.
STEP 6: Determine the actual circuit current STEP 4: Refer to the altitude derating curve
for each wire in the bundle and for the whole of figure 11-6, look for sea level and
bundle. If the values calculated in step #5 are 20,000 feet (on the abscissa) since these are
exceeded, select the next larger size wire and the conditions at which the load will be car-
repeat the calculations. ried. The wire must be derated by a factor of
1.0 and 0.91, respectively.
b. Example 2. Assume a harness (open or
braided), consisting of 12, size #12, 200 C STEP 5: Derate the size #12 in a bundle rat-
rated copper wires, will be operated in an am- ings by multiplying 29.2 amps at sea level and
bient of 25 C at sea level and 60 C at a 26.6 amps at 20,000 feet by 1.0 and 0.91, re-
20,000-foot altitude. All 12 wires will be op- spectively, to obtained 29.2 amps and
erated at or near their maximum capacity. 23.8 amps. The total bundle capacity at sea
level and 25 C ambient is
STEP 1: Refer to the single wire in free air 29.2x12=350.4 amps. At 20,000 feet and
curve in figure 11-4a, determine the tempera- 60 C ambient the bundle capacity is
ture difference of the wire to determine free air 23.8x12=285.6 amps. Each size #12 wire can
ratings. Since the wire will be in ambient of carry 29.2 amps at sea level, 25 C ambient or
25 C and 60 C and is rated at 200 C, the 23.8 amps at 20,000 feet, and 60 C ambient.
temperature differences are 200 C-25 C =
175 C and 200 C-60 C = 140 C respec- STEP 6: Determine the actual circuit current
tively. Follow the 175 C and the 140 C tem- for each wire in the bundle and for the bundle.
perature difference lines on figure 11-4a until If the values calculated in Step #5 are ex-
each intersects wire size line, the free air rat- ceeded, select the next larger size wire and re-
ings of size #12 are 68 amps and 61 amps, re- peat the calculations.
spectively.
11-76. GENERAL. Aircraft service im- manufacturer. Existing installed wire that
poses severe environmental condition on elec- needs replacement can thereby be identified as
trical wire. To ensure satisfactory service, in- to its performance capabilities, and the inad-
spect wire annually for abrasions, defective in- vertent use of a lower performance and unsuit-
sulation, condition of terminations, and poten- able replacement wire avoided.
tial corrosion. Grounding connections for
power, distribution equipment, and electro- (1) In addition to the type identification
magnetic shielding must be given particular imprinted by the original wire manufacturer,
attention to ensure that electrical bonding re- aircraft wire also contains its unique circuit
sistance has not been significantly increased by identification coding that is put on at the time
the loosening of connections or corrosion. of harness assembly. The traditional Hot
Stamp method has not been totally satisfac-
a. Wire Size. Wires must have sufficient tory in recent years when used on modern, ul-
mechanical strength to allow for service con- tra-thin-walled installations. Fracture of the
ditions. Do not exceed allowable voltage drop insulation wall and penetration to the conduc-
levels. Ensure that the wires are protected by tor of these materials by the stamping dies
system circuit protection devices, and that they have occurred. Later in service, when these
meet circuit current carrying requirements. If openings have been wetted by various fluids,
it is desirable to use wire sizes smaller serious arcing and surface tracking have dam-
than #20, particular attention should be given aged wire bundles.
to the mechanical strength and installation
handling of these wires, e.g. vibration, flexing, (2) Extreme care must be taken during
and termination. When used in interconnect- circuit identification by a hot stamp machine
ing airframe application, #24 gauge wire must on wire with a 10 mil wall or thinner. Alter-
be made of high strength alloy. native identification methods, such as Laser
Printing and Ink Jet, are coming into in-
b. Installation Precautions for Small creasing use by the industry. When such mod-
Wires. As a general practice, wires smaller ern equipment is not available, the use of
than size #20 must be provided with additional stamped identification sleeving should be con-
clamps, grouped with at least three other wires, sidered on thin-walled wire, especially when
and have additional support at terminations, insulation wall thickness falls below 10 mils.
such as connector grommets, strain-relief
clamps, shrinkable sleeving, or telescoping 11-77. AIRCRAFT WIRE MATERIALS.
bushings. They should not be used in applica- Only wire, specifically designed for airborne
tions where they will be subjected to excessive use, must be installed in aircraft.
vibration, repeated bending, or frequent dis-
connection from screw terminations. a. Authentic Aircraft Wire. Most air-
craft wire designs are to specifications that re-
c. Identification. All wire used on air- quire manufacturers to pass rigorous testing of
craft must have its type identification im- wires before being added to a Qualified Prod-
printed along its length. It is common practice ucts List (QPL) and being permitted to produce
to follow this part number with the five the wire. Aircraft manufacturers who maintain
digit/letter Commercial and Government En- their own wire specifications invariably exer-
tity (C.A.G.E). code identifying the wire cise close control on their approved
sources. Such military or original equipment ronment. Wire construction that is suitable for
manufacturer (OEM) wire used on aircraft the most severe environmental condition to be
should only have originated from these defined encountered should be selected. Wires are
wire mills. Aircraft wire from other unau- typically categorized as being suitable for ei-
thorized firms, and fraudulently marked with ther open wiring or protected wiring ap-
the specified identification, must be regarded plications. MIL-W-5088L, replaced by
as unapproved wire, and usually will be of AS50881A, wiring aerospace vehicle, Appen-
inferior quality with little or no process control dix A table A-I lists wires considered to have
testing. Efforts must be taken to ensure ob- sufficient abrasion and cut-through resistance
taining authentic, fully tested aircraft wire. to be suitable for open-harness construction.
MIL-W-5088L, replaced by AS50881A, wiring
b. Plating. Bare copper develops a sur- aerospace vehicle, Appendix A table A-II lists
face oxide coating at a rate dependent on tem- wires for protected applications. These wires
perature. This oxide film is a poor conductor are not recommended for aircraft interconnec-
of electricity and inhibits determination of tion wiring unless the subject harness is cov-
wire. Therefore, all aircraft wiring has a coat- ered throughout its length by a protective
ing of tin, silver, or nickel, that have far slower jacket. The wire temperature rating is typically
oxidation rates. a measure of the insulations ability to with-
stand the combination of ambient temperature
(1) Tin coated copper is a very common and current related conductor temperature rise.
plating material. Its ability to be successfully
soldered without highly active fluxes dimin- e. Insulation. There are many insulation
ishes rapidly with time after manufacture. It materials and combinations used on aircraft
can be used up to the limiting temperature of electrical wire. Characteristics should be cho-
150 C. sen based on environment; such as abrasion re-
sistance, arc resistance, corrosion resistance,
(2) Silver-coated wire is used where cut-through strength, dielectric strength, flame
temperatures do not exceed 200 C (392 F). resistant, mechanical strength, smoke emis-
sion, fluid resistance, and heat distortion. An
(3) Nickel coated wire retains its prop- explanation of many of the abbreviations is
erties beyond 260 C, but most aircraft wire identified in the glossary.
using such coated strands have insulation sys-
tems that cannot exceed that temperature on 11-78. SUBSTITUTIONS. In the repair
long-term exposure. Soldered terminations of and modification of existing aircraft, when a
nickel-plated conductor require the use of dif- replacement wire is required, the maintenance
ferent solder sleeves or flux than those used manual for that aircraft must first be reviewed
with tin or silver-plated conductor. to determine if the original aircraft manufac-
turer (OAM) has approved any substitution. If
c. Conductor Stranding. Because of not, then the OAM must be contacted for an
flight vibration and flexing, conductor round acceptable replacement.
wire should be stranded to minimize fatigue
breakage. a. MIL-W-5088L, replaced by AS50881A,
wiring aerospace vehicle, Appendix A lists wire
d. Wire Construction Versus Applica- types that have been approved for military
tion. The most important consideration in the
selection of aircraft wire is properly matching
the wires construction to the application envi-
aerospace applications in open and protected c. The use of current military specifica-
wiring applications. These wires could poten- tion, multi-conductor cables in place of OEM
tially be used for substitution when approved installed constructions may create
by the OAM. problems such as color sequence. Some civil-
ian aircraft are wired with the older color se-
b. Areas designated as severe wind and quence employing Red-Blue-Yellow as the
moisture problem (SWAMP) areas differ first three colors. Current military specifica-
from aircraft to aircraft but generally are con- tion, multi-conductor cables, in accordance
sidered to be areas such as wheel wells, near with MIL-C-27500, use White-Blue-Orange
wing flaps, wing folds, pylons, and other exte- for the initial three colors. Use of an alterna-
rior areas that may have a harsh environment. tive color code during modification without
Wires for these applications often have design adequate notation on wiring diagrams could
features incorporated into their construction severely complicate subsequent servicing of
that may make the wire unique; therefore an the aircraft. At the time of this writing,
acceptable substitution may be difficult, if not MIL-C-27500 is being revised to include the
impossible, to find. It is very important to use older color sequence and could eliminate this
the wire type recommended in the aircraft problem in the future.
manufacturers maintenance handbook.
11-84. [RESERVED.]
11-79.
11-85. AIRCRAFT WIRE TABLE. Ta- jacket, conduit, tray, or other covering is
bles 11-11 and 11-12 list wires used for the known as protected wire. (See table 11-12.)
transmission of signal and power currents in
aircraft. It does not include special purpose 11-88. SEVERE WIND AND MOISTURE
wires such as thermocouple, engine vibration PROBLEMS (SWAMP). Areas such as
monitor wire, fiber optics, data bus, and other wheel wells, wing fold and pylons, flap areas,
such wire designs. Fire resistant wire is in- and those areas exposed to extended weather
cluded because it is experiencing a wider ap- shall dictate selection and will require special
plication in aircraft circuits beyond that of the consideration. Insulation or jacketing will vary
fire detection systems. according to the environment. Suitable wire
types selected from MIL-W-22759 shall be
a. All wires in tables 11-11 and 11-12 used in these applications. (See table 11-11.)
have been determined to meet the flammability
requirements of Title 14 of the Code of Federal Suitable wire types selected from
Regulation (14 CFR) part 25, section MIL-W-22759 are preferred for areas that re-
25.869(a)(4) and the applicable portion of quire repeated bending and flexing of the wire.
part 1 of Appendix F of part 25. Consideration should be made to areas that re-
quire frequent component removal or repair.
b. The absence of any wire from ta- (See table 11-11.)
bles 11-11 and 11-12 are not to be construed as
being unacceptable for use in aircraft. How- 11-89. SHIELDED WIRE. With the in-
ever, the listed wires have all been reviewed crease in number of highly sensitive electronic
for such use and have been found suitable, or devices found on modern aircraft, it has be-
have a successful history of such usage. come very important to ensure proper shield-
ing for many electric circuits. Shielding is the
c. Explanations of the various insulation process of applying a metallic covering to
materials mentioned in table 11-11, by abbre- wiring and equipment to eliminate interference
viations, can be found in the glossary. caused by stray electromagnetic energy.
Shielded wire or cable is typically connected to
11-86. OPEN AIRFRAME INTERCON- the aircrafts ground at both ends of the wire,
NECTING WIRE. Interconnecting wire is or at connectors in the cable. Electromagnetic
used in point to point open harnesses, normally Interference (EMI) is caused when electro-
in the interior or pressurized fuselage, with magnetic fields (radio waves) induce high-
each wire providing enough insulation to resist frequency (HF) voltages in a wire or compo-
damage from handling and service exposure. nent. The induced voltage can cause system
(See table 11-11.) Electrical wiring is often in- inaccuracies or even failure, therefore putting
stalled in aircraft without special enclosing the aircraft and passengers at risk. Shielding
means. This practice is known as open wiring helps to eliminate EMI by protecting the pri-
and offers the advantages of ease of mainte- mary conductor with an outer conductor. Re-
nance and reduced weight. fer to MIL-DTL-27500, Cable, Power, Electri-
cal and Cable Special Purpose, Electrical
11-87. PROTECTED WIRE. Airborne Shielded and Unshielded General Specifica-
wire that is used within equipment boxes, or tions.
has additional protection, such as an exterior
MIL-W-22759/1 600 200 Fluoropolymer insulated TFE and TFE Silver coated copper
coated glass
MIL-W-22759/2 600 260 Fluoropolymer insulated TFE and TFE Nickel coated copper
coated glass
MIL-W-22759/3 600 260 Fluoropolymer insulated TFE -glass- Nickel coated copper
TFE
MIL-W-22759/4 600 200 Fluoropolymer insulated TFE -glass- Silver coated copper
FEP
MIL-W-22759/5 600 200 Fluoropolymer insulated extruded TFE Silver coated copper
MIL-W-22759/6 600 260 Fluoropolymer insulated extruded TFE Nickel coated copper
MIL-W-22759/7 600 200 Fluoropolymer insulated extruded TFE Silver coated copper
MIL-W-22759/8 600 260 Fluoropolymer insulated extruded TFE Nickel coated copper
MIL-W-22759/9 1000 200 Fluoropolymer insulated extruded TFE Silver coated copper
MIL-W-22759/10 1000 260 Fluoropolymer insulated extruded TFE Nickel coated copper
MIL-W-22759/13 600 135 Fluoropolymer insulated FEP PVF2 Tin coated copper,
MIL-W-22759/16 600 150 Fluoropolymer insulated extruded Tin coated copper,
ETFE
MIL-W-22759/17 600 150 Fluoropolymer insulated extruded Silver coated high strength cop-
ETFE per alloy
MIL-W-22759/20 1000 200 Fluoropolymer insulated extruded TFE Silver coated high strength cop-
per alloy
MIL-W-22759/21 1000 260 Fluoropolymer insulated extruded TFE Nickel coated high strength
copper alloy
MIL-W-22759/34 600 150 Fluoropolymer insulated crosslinked Tin coated copper
modified ETFE
MIL-W-22759/35 600 200 Fluoropolymer insulated crosslinked Silver coated high strength cop-
modified ETFE per alloy
MIL-W-22759/41 600 200 Fluoropolymer insulated crosslinked Nickel coated copper
modified ETFE
MIL-W-22759/42 600 200 Fluoropolymer insulated crosslinked Nickel coated high strength
modified ETFE copper alloy
MIL-W-22759/43 600 200 Fluoropolymer insulated crosslinked Silver coated copper
modified ETFE
MIL-W-25038/3/2/ 600 260 See specification sheet * See specification sheet
MIL-W-81044/6 600 150 Crosslinked polyalkene Tin coated copper
MIL-W-81044/7 600 150 Crosslinked polyalkene Silver coated high strength cop-
per alloy
MIL-W-81044/9 600 150 Crosslinked polyalkene Tin coated copper
MIL-W-81044/10 600 150 Crosslinked polyalkene Silver coated high strength cop-
per alloy
* Inorganic Fibers - Glass - TFE
MIL-W-22759/11 600 200 Fluoropolymer insulated extruded TFE Silver coated copper
MIL-W-22759/12 600 260 Fluoropolymer insulated extruded TFE Nickel coated copper
MIL-W-22759/14 600 135 Fluoropolymer insulated FEP-PVF2 Tin coated copper
MIL-W-22759/15 600 135 Fluoropolymer insulated FEP-PVF2 Silver plated high strength copper
alloy
MIL-W-22759/18 600 150 Fluoropolymer insulated extruded ETFE Tin coated copper
MIL-W-22759/19 600 150 Fluoropolymer insulated extruded ETFE Silver coated high strength cop-
per alloy
MIL-W-22759/22 600 200 Fluoropolymer insulated extruded TFE Silver coated high strength cop-
per alloy
MIL-W-22759/23 600 260 Fluoropolymer insulated extruded TFE Nickel coated high strength cop-
per alloy
MIL-W-22759/32 600 150 Fluoropolymer insulated crosslinked Tin coated copper
modified ETFE
MIL-W-22759/33 600 200 Fluoropolymer insulated crosslinked Silver coated high strength cop-
modified ETFE per alloy
MIL-W-22759/44 600 200 Fluoropolymer insulated crosslinked Silver coated copper
modified ETFE
MIL-W-22759/45 600 200 Fluoropolymer insulated crosslinked Nickel coated copper
modified ETFE
MIL-W-22759/46 600 200 Fluoropolymer insulated crosslinked Nickel coated high strength cop-
modified ETFE per alloy
MIL-W-81044/12 600 150 Crosslinked polyalkene - PVF2 Tin coated copper
MIL-W-81044/13 600 150 Crosslinked polyalkene - PVF2 Silver coated high strength cop-
per alloy
MIL-W-81381/17 600 200 Fluorocarbon polyimide Silver coated copper
MIL-W-81381/18 600 200 Fluorocarbon polyimide Nickel coated copper
MIL-W-81381/19 600 200 Fluorocarbon polyimide Silver coated high strength cop-
per alloy
MIL-W-81381/20 600 200 Fluorocarbon polyimide Nickel coated high strength cop-
per alloy
MIL-W-81381/21 600 150 Fluorocarbon polyimide Tin coated copper
11-95. [RESERVED.]
11-90.
11-96. GENERAL. Wires and cables e. Clamp retaining screws are properly
should be inspected for adequacy of support, secured so that the movement of wires and ca-
protection, and general condition throughout. bles is restricted to the span between the points
The desirable and undesirable features in air- of support and not on soldered or mechanical
craft wiring installations are listed below and connections at terminal posts or connectors.
indicate conditions that may or may not exist.
Accordingly, aircraft wiring must be visually f. Wire and cables are properly supported
inspected for the following requirements: and bound so that there is no interference with
other wires, cables, and equipment.
CAUTION: For personal safety, and
to avoid the possibility of fire, turn off g. Wires and cables are adequately sup-
all electrical power prior to starting ported to prevent excessive movement in areas
an inspection of the aircraft electrical of high vibration.
system or performing maintenance.
h. Insulating tubing is secured by tying,
a. Wires and cables are supported by tie straps or with clamps.
suitable clamps, grommets, or other devices at
intervals of not more than 24 inches, except i. Continuous lacing (spaced 6 inches
when contained in troughs, ducts, or conduits. apart) is not used, except in panels and junc-
The supporting devices should be of a suitable tion boxes where this practice is optional.
size and type, with the wires and cables held When lacing is installed in this manner, out-
securely in place without damage to the insu- side junction boxes should be removed and re-
lation. placed with individual loops.
n. Ensure cable supports do not restrict fuel, or oxygen line, fuel tank wall, or other
the wires or cables in such a manner as to in- low voltage wiring that enters a fuel tank and
terfere with operation of equipment shock requires electrical isolation to prevent an igni-
mounts. tion hazard. Where 6 inch spacing cannot
practically be provided, a minimum of 2 inches
o. Do not use tape, tie straps, or cord for must be maintained between wiring and such
primary support. lines, related equipment, fuel tank walls and
low voltage wiring that enters a fuel tank.
p. Make sure that drain holes are pres- Such wiring should be closely clamped and
ent in drip loops or in the lowest portion of rigidly supported and tied at intervals such that
tubing placed over the wiring. contact betwe4en such lines, related equip-
ment, fuel tank walls or other wires, would not
q. Ensure that wires and cables are occur, assuming a broken wire and a missing
routed in such a manner that chafing will not wire tie or clamp.
occur against the airframe or other compo-
nents. x. Ensure that a trap or drip loop is
provided to prevent fluids or condensed mois-
r. Ensure that wires and cables are po- ture from running into wires and cables
sitioned in such a manner that they are not dressed downward to a connector, terminal
likely to be used as handholds or as support for block, panel, or junction box.
personal belongings and equipment.
y. Wires and cables installed in bilges
s. Ensure that wires and cables are and other locations where fluids may be
routed, insofar as practicable, so that they are trapped are routed as far from the lowest point
not exposed to damage by personnel moving as possible or otherwise provided with a
within the aircraft. moisture-proof covering.
t. Ensure that wires and cables are lo- z. Separate wires from high-temperature
cated so as not to be susceptible to damage by equipment, such as resistors, exhaust stacks,
the storage or shifting of cargo. heating ducts, etc., to prevent insulation break-
down. Insulate wires that must run through
u. Ensure that wires and cables are hot areas with a high-temperature insulation
routed so that there is not a possibility of dam- material such as fiberglass or PTFE. Avoid
age from battery electrolytes or other corrosive high-temperature areas when using cables
fluids. having soft plastic insulation such as polyeth-
ylene, because these materials are subject to
v. Ensure that wires and cables are ade- deterioration and deformation at elevated tem-
quately protected in wheel wells and other ar- peratures. Many coaxial cables have this type
eas where they may be exposed to damage of insulation.
from impact of rocks, ice, mud, etc. (If re-
routing of wires or cables is not practical, pro- aa. The minimum radius of bends in
tective jacketing may be installed). This type wire groups or bundles must not be less than
of installation must be held to a minimum. 10 times the outside diameter of the largest
wire or cable, except that at the terminal strips
w. Where practical, route electrical wires where wires break out at terminations or re-
and cables above fluid lines and provide a 6
inch separation from any flammable liquid,
verse direction in a bundle. Where the wire is (4) Allow shifting of equipment, as
suitably supported, the radius may be 3 times necessary, to perform alignment, servicing,
the diameter of the wire or cable. Where it is tuning, removal of dust covers, and changing
not practical to install wiring or cables within of internal components while installed in air-
the radius requirements, the bend should be craft.
enclosed in insulating tubing. The radius for
thermocouple wire should be done in accor- ff. Ensure that unused wires are indi-
dance with the manufacturers recommenda- vidually dead-ended, tied into a bundle, and
tion and shall be sufficient to avoid excess secured to a permanent structure. Each wire
losses or damage to the cable. should have strands cut even with the insula-
tion and a pre-insulated closed end connector
bb. Ensure that RF cables, e.g., coaxial or a 1-inch piece of insulating tubing placed
and triaxial are bent at a radius of no less than over the wire with its end folded back and tied.
6 times the outside diameter of the cable.
gg. Ensure that all wires and cables are
cc. Ensure that wires and cables, that identified properly at intervals of not more
are attached to assemblies where relative than 15 inches. Coaxial cables are identified at
movement occurs (such as at hinges and ro- both equipment ends.
tating pieces; particularly doors, control sticks,
control wheels, columns, and flight control 11-97. WIRING REPLACEMENT. Wir-
surfaces), are installed or protected in such a ing must be replaced with equivalent wire (see
manner as to prevent deterioration of the wires paragraph 11-78) when found to have any of
and cables caused by the relative movement of the following defects:
the assembled parts.
a. Wiring that has been subjected to
dd. Ensure that wires and electrical ca- chafing or fraying, that has been severely dam-
bles are separated from mechanical control ca- aged, or that primary insulation is suspected of
bles. In no instance should wire be able to being penetrated.
come closer than 1/2 inch to such controls
when light hand pressure is applied to wires or b. Wiring on which the outer insulation is
controls. In cases where clearance is less than brittle to the point that slight flexing causes it
this, adequate support must be provided to to crack.
prevent chafing.
c. Wiring having weather-cracked outer
ee. Ensure that wires and cables are insulation.
provided with enough slack to meet the fol-
lowing requirements: d. Wiring that is known to have been ex-
posed to electrolyte or on which the insulation
(1) Permit ease of maintenance. appears to be, or is suspected of being, in an
initial stage of deterioration due to the effects
(2) Prevent mechanical strain on the of electrolyte.
wires, cables, junctions, and supports.
e. Check wiring that shows evidence of specific for the degradation mode of the insu-
overheating (even if only to a minor degree) lation. If the samples fail either the electrical
for the cause of the overheating. or chemical integrity tests, then the wiring in
the area surrounding the sampling area is a
f. Wiring on which the insulation has be- candidate for replacement.
come saturated with engine oil, hydraulic fluid,
or another lubricant. 11-98. TERMINALS AND TERMINAL
BLOCKS. Inspect to ensure that the follow-
g. Wiring that bears evidence of having ing installation requirements are met:
been crushed or severely kinked.
a. Insulating tubing is placed over termi-
h. Shielded wiring on which the metallic nals (except pre-insulated types) to provide
shield is frayed and/or corroded. Cleaning electrical protection and mechanical support
agents or preservatives should not be used to and is secured to prevent slippage of the tubing
minimize the effects of corrosion or deteriora- from the terminal.
tion of wire shields.
b. Terminal module blocks are securely
i. Wiring showing evidence of breaks, mounted and provided with adequate electrical
cracks, dirt, or moisture in the plastic sleeves clearances or insulation strips between
placed over wire splices or terminal lugs. mounting hardware and conductive parts, ex-
cept when the terminal block is used for
j. Sections of wire in which splices occur grounding purposes.
at less than 10-foot intervals, unless specifi-
cally authorized, due to parallel connections, c. Terminal connections to terminal
locations, or inaccessibility. module block studs and nuts on unused studs
are tight.
k. When replacing wiring or coaxial ca-
bles, identify them properly at both equipment d. Evidence of overheating and corro-
and power source ends. sion is not present on connections to terminal
module block studs.
l. Wire substitution-In the repair and
modification of existing aircraft, when a re- e. Physical damage to studs, stud threads,
placement wire is required, the maintenance and terminal module blocks is not evident.
manual for that aircraft should first be re- Replace cracked terminal strips and those
viewed to determine if the original aircraft studs with stripped threads.
manufacturer (OAM) has approved any sub-
stitution. If not, then the OAM should be f. The number of terminal connections
contacted for an acceptable replacement. to a terminal block stud does not exceed four,
unless specifically authorized.
m. Testing of the electrical and chemi-
cal integrity of the insulation of sample wires g. Shielding should be dead-ended with
taken from areas of the aircraft that have expe- suitable insulated terminals.
rienced wiring problems in the past, can be
used to supplement visual examination of the h. All wires, terminal blocks, and indi-
wire. The test for chemical integrity should be vidual studs are clearly identified to corre-
spond to aircraft wiring manuals.
i. Terminations should be made using so that tightening of the cable clamp adapter
terminals of the proper size and the appropriate cap provides sufficient grip on the wires to
terminal crimping tools. keep tension from being applied to the con-
nector pins.
11-99. FUSES AND FUSE HOLDERS.
Inspect as follows: d. Make sure unused plugs and recep-
tacles are covered to prevent inclusion of dust
a. Check security of connections to fuse and moisture. Receptacles should have metal
holders. or composite dust caps attached by their nor-
mal mating method. Plugs may have a dust
b. Inspect for the presence of corrosion cap similar to above or have a piece of
and evidence of overheating on fuses and fuse polyolefin shrink sleeving shrunk over the
holders. Replace corroded fuses and clean connector, starting from the backshell threads,
fuse holders. If evidence of overheating is with a tail sufficiently long enough to double-
found, check for correct rating of fuse. back over the connector and be tied with poly-
ester lacing tape behind the coupling nut. The
c. Check mounting security of fuse cable identification label should be visible be-
holder. hind the connector or a tag should be attached
identifying the associated circuit or attaching
d. Inspect for replenishment of spare equipment. The connector should be attached
fuses used in flight. Replace with fuses of ap- to structure by its normal mounting means or
propriate current rating only. by the use of appropriate clamps.
e. Inspect for exposed fuses susceptible e. Ensure that connectors are fully mated
to shorting. Install cover of nonconducting by checking position and tightness of coupling
material if required. ring or its alignment with fully mated indicator
line on receptacle, if applicable.
11-100. CONNECTORS. Ensure reliability
of connectors by verifying that the following f. Ensure that the coupling nut of MS
conditions are met or that repairs are effected connectors is safetied, by wire or other me-
as required. chanical locking means, as required by appli-
cable aircraft instructional manuals.
a. Inspect connectors for security and
evidence of overheating (cause of over-heating g. Ensure that moisture-absorbent ma-
must be corrected), and exteriors for corrosion terial is not used as fill for MS3057 clamps
and cracks. Also, wires leading to connectors or adapters.
must be inspected for deterioration due to
overheating. Replace corroded connections h. Ensure that there is no evidence of
and overheated connectors. deterioration such as cracking, missing, or
disintegration of the potting material.
b. Ensure installation of cable clamp
(reference MIL-C-85049) adapters on applica- i. Identical connectors in adjacent loca-
ble MS connectors, except those that are tions can lead to incorrect connections. When
moisture-proof. such installations are unavoidable, the attached
wiring must be clearly identified and must be FLEXIBLE METALLIC AND RIGID
routed and clamped so that it cannot be mis- NONMETALLIC. Inspection of conduit as-
matched. semblies should ascertain that:
11-101. JUNCTION BOXES, PANELS, c. Conduits will not trap fluids or con-
SHIELDS, AND MICROSWITCH HOUS- densed moisture. Suitable drain holes should
INGS. Examine housing assemblies to ascer- be provided at the low points.
tain the following:
d. Bonding clamps do not cause damage
a. Verify that one or more suitable to the conduit.
holes, about 3/8-inch diameter, but not less
than 1/8-inch diameter, are provided at the e. Weatherproof shields on flexible con-
lowest point of the box, except vapor-tight duits of the nose and main landing gear and in
boxes, to allow for drainage with the aircraft wheel wells are not broken; that metallic braid
on the ground or in level flight. of weatherproof conduit is not exposed; and
that conduit nuts, ferrules, and conduit fittings
b. Verify that vapor tight or explosion are installed securely.
proof boxes are externally labeled VAPOR-
TIGHT or EXPLOSION PROOF. f. Ends of open conduits are flared or
routed to avoid sharp edges that could chafe
c. Verify that boxes are securely wires exiting from the conduit.
mounted.
11-103. JUNCTIONS. Ensure that only air-
d. Verify that boxes are clean internally craft manufacturer approved devices, such as
and free of foreign objects. solderless type terminals, terminal blocks,
connectors, disconnect splices, permanent
e. Verify that safety wiring is installed splices, and feed-through bushings are used for
on all lid fasteners on J-boxes, panels, shields, cable junctions. Inspect for the provisions
or microswitch housings which are installed in outlined below:
areas not accessible for inspection in flight,
unless the fasteners incorporate self-locking a. Electrical junctions should be pro-
devices. tected from short circuits resulting from
movement of personnel, cargo, cases, and
f. Verify that box wiring is properly other loose or stored materials. Protection
aligned. should be provided by covering the junction,
installing them in junction boxes, or by locat-
g. Verify that there are no unplugged, un- ing them in such a manner that additional pro-
used holes (except drainage holes) in boxes. tection is not required, etc.
11-116. GROUP AND BUNDLE TIES. A ensure all edges are rounded to protect the wire
wire bundle consists of a quantity of wires insulation.
fastened or secured together and all traveling
in the same direction. Wire bundles may con- 11-117. MINIMUM WIRE BEND RADII.
sist of two or more groups of wires. It is often The minimum radii for bends in wire groups or
advantageous to have a number of wire groups bundles must not be less than 10 times the out-
individually tied within the wire bundle for side diameter of their largest wire. They may
ease of identification at a later date. (See fig- be bent at six times their outside diameters at
ure 11-7.) Comb the wire groups and bundles breakouts or six times the diameter where they
so that the wires will lie parallel to each other must reverse direction in a bundle, provided
and minimize the possibility of insulation that they are suitably supported.
abrasion. A combing tool, similar to that
shown in figure 11-8, may be made from any a. RF cables should not bend on a radius
suitable insulating material, taking care to of less than six times the outside diameter of
the cable.
11-122. MOISTURE PROTECTION, sunlight when aircraft are parked for extended
WHEEL WELLS, AND LANDING GEAR periods should also be taken into account.
AREAS. Wires such as in fire detection, fire extin-
guishing, fuel shutoff, and fly-by-wire flight
a. Wires located on landing gear and in control systems that must operate during and
the wheel well area can be exposed to many after a fire, must be selected from types that
hazardous conditions if not suitably protected. are qualified to provide circuit integrity after
Where wire bundles pass flex points, there exposure to fire for a specified period. Wire
must not be any strain on attachments or ex- insulation deteriorates rapidly when subjected
cessive slack when parts are fully extended or to high temperatures. Do not use wire with
retracted. The wiring and protective tubing soft polyethylene insulation in areas subject to
must be inspected frequently and replaced at high temperatures. Use only wires or cables
the first sign of wear. with heat resistance shielding or insulation.
11-134. [RESERVED.]
11-127.
11-145. [RESERVED.]
11-140.
11-146. GENERAL. Wires and wire bun- b. Clamps lined with nonmetallic mate-
dles must be supported by using clamps meet- rial should be used to support the wire bundle
ing Specification MS-21919, or plastic cable along the run. Tying may be used between
straps in accessible areas if correctly applied clamps, but should not be considered as a sub-
within the restrictions of paragraph 11-158. stitute for adequate clamping. Adhesive tapes
Clamps and other primary support devices are subject to age deterioration and, therefore,
must be constructed of materials that are com- are not acceptable as a clamping means.
patible with their installation and environment,
in terms of temperature, fluid resistance, expo- c. The back of the clamp, whenever
sure to ultraviolet (UV) light, and wire bundle practical, should be rested against a structural
mechanical loads. They should be spaced at member. Stand-offs should be used to main-
intervals not exceeding 24 inches. Clamps on tain clearance between the wires and the
wire bundles should be selected so that they structure. Clamps must be installed in such a
have a snug fit without pinching wires, as manner that the electrical wires do not come in
shown in figure 11-11 through figure 11-13. contact with other parts of the aircraft when
subjected to vibration. Sufficient slack should
CAUTION: The use of metal clamps be left between the last clamp and the electri-
on coaxial RF cables may cause prob- cal equipment to prevent strain at the terminal
lems if clamp fit is such that RF ca- and to minimize adverse effects on shock-
bles original cross-section is distorted. mounted equipment. Where wires or wire
bundles pass through bulkheads or other
a. Clamps on wire bundles should not structural members, a grommet or suitable
allow the bundle to move through the clamp clamp should be provided to prevent abrasion.
when a slight axial pull is applied. Clamps on
RF cables must fit without crushing and must d. When wire bundle is clamped into
be snug enough to prevent the cable from position, if there is less than 3/8-inch clearance
moving freely through the clamp, but may al- between the bulkhead cutout and the wire bun-
low the cable to slide through the clamp when dle, a suitable grommet should be installed as
a light axial pull is applied. The cable or wire indicated in figure 11-14. The grommet may
bundle may be wrapped with one or more turns be cut at a 45 degree angle to facilitate instal-
of electrical tape when required to achieve this lation, provided it is cemented in place and the
fit. Plastic clamps or cable ties must not be slot is located at the top of the cutout.
used where their failure could result in inter-
ference with movable controls, wire bundle 11-147. WIRE AND CABLE CLAMPS
contact with movable equipment, or chafing INSPECTION. Inspect wire and cable
damage to essential or unprotected wiring. clamps for proper tightness. Where cables
They must not be used on vertical runs where pass through structure or bulkheads, inspect
inadvertent slack migration could result in for proper clamping and grommets. Inspect
chafing or other damage. Clamps must be in- for sufficient slack between the last clamp and
stalled with their attachment hardware posi- the electronic equipment to prevent strain at
tioned above them, wherever practicable, so the cable terminals and to minimize adverse
that they are unlikely to rotate as the result of effects on shock-mounted equipment.
wire bundle weight or wire bundle chafing.
(See figure 11-11.).
11-154. [RESERVED.]
11-148.
Wire Size Conductor material Number of strands per Total allowable nicked and
conductor broken strands
of the strap would permit wiring to move 12 inches apart. A tie consists of a clove hitch,
against parts which could damage the insula- around the wire group or bundle, secured by a
tion and foul mechanical linkages or other square knot as shown in figure 11-17.
moving mechanical parts. They also may not
be used where they could be exposed to UV c. Plastic Ties. Refer to Para-
light, unless the straps are resistant to such ex- graph 11-220 and table 11-21.
posure.
11-159. INSULATION TAPE. Insulation
a. Lacing. Lace wire groups or bundles tape should be of a type suitable for the appli-
inside junction boxes or other enclosures. cation, or as specified for that particular use.
Single cord-lacing method, shown in fig- Insulation tape should be used primarily as a
ure 11-15, and tying tape, meeting specifica- filler under clamps and as secondary support.
tion MIL-T-43435, may be used for wire Nonadhesive tape may be used to wrap around
groups of bundles 1-inch in diameter or less. wiring for additional protection, such as in
The recommended knot for starting the single wheel wells. All tape should have the ends
cord-lacing method is a clove hitch secured by tied or otherwise suitably secured to prevent
a double-looped overhand knot as shown in unwinding. Tape used for protection should be
figure 11-15, step a. Use the double cord- applied so that overlapping layers shed liquids.
lacing method on wire bundles 1-inch in di- Drainage holes should be provided at all trap
ameter or larger as shown in figure 11-16. points and at each low point between clamps.
When using the double cord-lacing method, Plastic tapes, that absorb moisture or have
employ a bowline on a bight as the starting volatile plasticizers that produce chemical re-
knot. actions with other wiring, should not be used.
(Reference MIL-W-5088.)
b. Tying. Use wire group or bundle ties
where the supports for the wire are more than
11-166. [RESERVED.]
11-160.
11-167. GENERAL. Splicing is permitted c. There should not be more than one
on wiring as long as it does not affect the reli- splice in any one wire segment between any
ability and the electromechanical characteris- two connectors or other disconnect points, ex-
tics of the wiring. Splicing of power wires, cept; when attaching to the spare pigtail lead of
coaxial cables, multiplex bus, and large gauge a potted connector, to splice multiple wires to
wire must have approved data. a single wire, to adjust wire size to fit connec-
tor contact crimp barrel size, and to make an
a. Splicing of electrical wire should be approved repair. (Reference MIL-W-5088,
kept to a minimum and avoided entirely in now AS50881A, and NAVAIR 01-1A-505.)
locations subject to extreme vibrations.
Splicing of individual wires in a group or bun- d. Splices in bundles must be staggered
dle should have engineering approval and the so as to minimize any increase in the size of
splice(s) should be located to allow periodic the bundle, preventing the bundle from fitting
inspection. into its designated space, or cause congestion
that will adversely affect maintenance. (See
b. Many types of aircraft splice connec- figure 11-18.)
tors are available for use when splicing indi-
vidual wires. Use of a self-insulated splice e. Splices should not be used within
connector is preferred; however, a noninsu- 12 inches of a termination device, except for
lated splice connector may be used provided paragraph f below.
the splice is covered with plastic sleeving that
is secured at both ends. Environmentally f. Splices may be used within 12 inches
sealed splices, that conform to MIL-T-7928, of a termination device when attaching to the
provide a reliable means of splicing in pigtail spare lead of a potted termination de-
SWAMP areas. However, a noninsulated vice, or to splice multiple wires to a single
splice connector may be used, provided the wire, or to adjust the wire sizes so that they are
splice is covered with dual wall shrink compatible with the contact crimp barrel sizes.
sleeving of a suitable material.
g. Selection of proper crimping tool, re-
fer to paragraph 11-178.
11-173. [RESERVED.]
11-168.
11-174. GENERAL. Terminals are attached b. Terminal Strips. Wires are usually
to the ends of electrical wires to facilitate con- joined at terminal strips. A terminal strip fit-
nection of the wires to terminal strips or items ted with barriers should be used to prevent the
of equipment. The tensile strength of the wire- terminals on adjacent studs from contacting
to-terminal joint should be at least equivalent each other. Studs should be anchored against
to the tensile strength of the wire itself, and its rotation. When more than four terminals are to
resistance negligible relative to the normal re- be connected together, a small metal bus
sistance of the wire. should be mounted across two or more adja-
cent studs. In all cases, the current should be
a. Selection of Wire Terminals. The carried by the terminal contact surfaces and not
following should be considered in the selection by the stud itself. Defective studs should be
of wire terminals. replaced with studs of the same size and mate-
rial since terminal strip studs of the smaller
(1) Current rating. sizes may shear due to overtightening the nut.
The replacement stud should be securely
(2) Wire size (gauge) and insulation mounted in the terminal strip and the terminal
diameter. securing nut should be tight. Terminal strips
should be mounted in such a manner that loose
(3) Conductor material compatibility. metallic objects cannot fall across the termi-
nals or studs. It is good practice to provide at
(4) Stud size. least one spare stud for future circuit expan-
sion or in case a stud is broken. Terminal strips
(5) Insulation material compatibility. that provide connection of radio and electronic
systems to the aircraft electrical system should
(6) Application environment. be inspected for loose connections, metallic
objects that may have fallen across the termi-
(7) Solder/solderless. nal strip, dirt and grease accumulation, etc.
These type conditions can cause arcing which
Pre-insulated crimp-type ring-tongue terminals may result in a fire, or system failures.
are preferred. The strength, size, and support-
ing means of studs and binding posts, as well c. Terminal Lugs. Wire terminal lugs
as the wire size, should be considered when should be used to connect wiring to terminal
determining the number of terminals to be at- block studs or equipment terminal studs. No
tached to any one post. In high-temperature more than four terminal lugs or three terminal
applications, the terminal temperature rating lugs and a bus bar should be connected to any
must be greater than the ambient temperature one stud. Total number of terminal lugs per
plus current related temperature rise. Use of stud includes a common bus bar joining adja-
nickel-plated terminals and of uninsulated ter- cent studs. Four terminal lugs plus a common
minals with high-temperature insulating bus bar thus are not permitted on one stud.
sleeves should be considered. Terminal blocks Terminal lugs should be selected with a stud
should be provided with adequate electrical hole diameter that matches the diameter of the
clearance or insulation strips between mount- stud. However, when the terminal lugs at-
ing hardware and conductive parts. tached to a stud vary in diameter, the greatest
diameter should be placed on the bottom and Class 1 terminal lugs to be used for service re-
the smallest diameter on top. Tightening ter- placement of any Class 2 terminal lugs in-
minal connections should not deform the ter- stalled.
minal lugs or the studs. Terminal lugs should
be so positioned that bending of the terminal g. Termination of Shielded Wire. For
lug is not required to remove the fastening termination of shielded wire refer to
screw or nut, and movement of the terminal MIL-DTL-27500.
lugs will tend to tighten the connection.
11-175. ATTACHMENT OF TERMI-
d. Copper Terminal Lugs. Solderless NALS TO STUDS. Connectors and terminals
crimp style, copper wire, terminal lugs should in aircraft require special attention to ensure a
be used and conform to MIL-T-7928. Spacers safe and satisfactory installation. Every possi-
or washers should not be used between the bility of short circuits, due to misinstallation,
tongues of terminal lugs. poor maintenance, and service life, should be
addressed in the design. Electrical equipment
e. Aluminum Terminal Lugs. The alu- malfunction has frequently been traced to poor
minum terminal lugs conforming to terminal connections at terminal boards.
MIL-T-7099 (MS-25435, MS-25436, Loose, dirty, or corroded contact surfaces can
MS-25437, and MS-25438) should be crimped produce localized heating that may ignite
to aluminum wire only. The tongue of the nearby combustible materials or overheat adja-
aluminum terminal lugs or the total number of cent wire insulation. (See paragraph 11-178)
tongues of aluminum terminal lugs when
stacked, should be sandwiched between two 11-176. STUDS AND INSULATORS. The
MS-25440 flat washers when terminated on following recommendations concerning studs
terminal studs. Spacers or washers should not also apply to other feed-through conductors.
be used between the tongues of terminal lugs.
Special attention should be given to aluminum a. Current Carrying Stud Resistance.
wire and cable installations to guard against Due to heat loss arising from wire-to-lug and
conditions that would result in excessive volt- lug-to-stud voltage drop, the resistance per unit
age drop and high resistance at junctions that length of a current carrying stud should not be
may ultimately lead to failure of the junction. greater than that of the wire.
Examples of such conditions are improper in-
stallation of terminals and washers, improper b. Size of Studs. In designing the stud for
torsion (torquing of nuts), and inadequate a feed-through connection, attention should be
terminal contact areas. given to the higher resistance of brass, as com-
pared to copper. A suggested method of de-
f. Class 2 Terminal Lugs. The Class 2 termining the size is to use a current density in
terminal lugs conforming to MIL-T-7928 may the stud equivalent to that of the wire, com-
be used for installation, provided that in such pensating for the difference of resistance of the
installations, Class 1 terminal lugs are ade- metals. Consideration should also be given to
quate for replacement without rework of in- mechanical strength.
stallation or terminal lugs. Class 2 terminal
lugs should be the insulated type, unless the c. Support for Studs. The main stud
conductor temperature exceeds 105 C. In that support in the feed-through insulation should
case uninsulated terminal lugs should be used. be independent of the attachment of the lugs to
Parts lists should indicate the appropriate the stud. Therefore, loosening of the insula-
tion support of the stud will not affect the
electric contact efficiency. In other words, the 11-178. CRIMP ON TERMINAL LUGS
contact pressure on the wire lugs should not in AND SPLICES (pre-insulated crimp type).
any way be affected by the loosening of the The crimp on terminal lugs and splices must
stud in the insulator. be installed using a high quality ratchet-type,
crimping tool. We recommend the use of the
d. Support of Wire at Studs. Unless proper calibrated tool. Aircraft quality crimp
some other positive locking action is provided, tools are manufactured to standards. Such
the lug or wire should be supported next to the tools are provided with positioners for the wire
stud to prevent loosening the connection with a size and are adjusted for each wire size. It is
side pull on the wire. Torque recommenda- essential that the crimp depth be appropriate
tions for attaching electrical wiring devices to for each wire size. If the crimp is too deep or
terminal boards or blocks, studs, posts, etc., not deep enough, it may break or cut individ-
are normally found in the manufacturers ual strands, or it may not be tight enough to
maintenance instruction manual. retain the wire in the terminal or connector.
Crimps that are not tight enough are also sus-
e. Feed-Through Insulator and Stud ceptible to high resistance due to corrosion
Design. Feed-through insulator design should build-up between the crimped terminal and the
be such as to prevent a loose insulator from wire. MIL-C22520/2 or MIL-T-DTl2250G
failing to provide circuit isolation. It should specification covers in detail the general re-
not be able to move from between the stud and quirement for crimp tools, inspection gages
the structure, thus allowing the two to come and tool kits.
into contact. The assembly should be so de-
signed that it is impossible to inadvertently a. Hand, portable, and stationary
misassemble the parts so that faults will result. power tools are available for crimping termi-
Also, it is desirable to provide means to pre- nal lugs. These tools crimp the barrel to the
vent the feed-through stud from turning while conductor, and simultaneously from the insu-
tightening the connection. lation support to the wire insulation.
11-177. WIRE TERMINALS AND BIND- b. Crimp tools must be carefully in-
ING POSTS. All wire terminals in or on spected:
electrical equipment, except case ground, must
be firmly held together with two nuts or suit- (1) Insure that the full cycle ratchet
able locking provisions, or should be secured mechanism is tamper-proof so that it cannot be
in a positive manner to equipment in such a disengaged prior to or during the crimp cycle.
way that no insulation material is involved in
maintaining physical pressure between the (2) If the tool does not function or faults
various current carrying members of an electri- are found, reject the tool and send the tool to
cal connection. Terminal studs or binding be repaired.
posts should be of a size that is entirely ade-
quate for the current requirements of the (3) The tool calibration and adjustments
equipment and have sufficient mechanical are make only by the manufacturer or an ap-
strength to withstand the torque required to proved calibration laboratory.
attach the cable to the equipment. All termi-
nals on equipment should have barriers and (4) Suitable gages of the Go/No Go
covers provided by equipment manufacturers. type are available and shall be used prior to
11-184. [RESERVED.]
11-180.
11-185. GENERAL. One of the more im- ground return should be labeled ac Right.
portant factors in the design and maintenance The return currents for the left generator
of aircraft electrical systems is proper bonding should be connected to a ground point labeled
and grounding. Inadequate bonding or ac Left
grounding can lead to unreliable operation of
systems, e.g., EMI, electrostatic discharge b. Current Return Paths. The design of
damage to sensitive electronics, personnel the ground return circuit should be given as
shock hazard, or damage from lightning strike. much attention as the other leads of a circuit.
This section provides an overview of the prin- A requirement for proper ground connections
ciples involved in the design and maintenance is that they maintain an impedance that is es-
of electrical bonding and grounding. sentially constant. Ground return circuits
SAE ARP-1870 provides for more complete should have a current rating and voltage drop
detailed information on grounding and bond- adequate for satisfactory operation of the con-
ing, and the application of related hardware. nected electrical and electronic equipment.
EMI problems, that can be caused by a sys-
11-186. GROUNDING. Grounding is the tems power wire, can be reduced substantially
process of electrically connecting conductive by locating the associated ground return near
objects to either a conductive structure or some the origin of the power wiring (e.g. circuit
other conductive return path for the purpose of breaker panel) and routing the power wire and
safely completing either a normal or fault cir- its ground return in a twisted pair. Special care
cuit. should be exercised to ensure replacement on
ground return leads. The use of numbered in-
a. Types of Grounding. If wires carrying sulated wire leads instead of bare grounding
return currents from different types of sources, jumpers may aid in this respect. In general,
such as signals of DC and AC generators, are equipment items should have an external
connected to the same ground point or have a ground connection, even when internally
common connection in the return paths, an in- grounded. Direct connections to a magnesium
teraction of the currents will occur. Mixing (which may create a fire hazard) structure must
return currents from various sources should be not be used for ground return.
avoided because noise will be coupled from
one source to another and can be a major c. Heavy-Current Grounds. Power
problem for digital systems. To minimize the ground connections, for generators, trans-
interaction between various return currents, former rectifiers, batteries, external power re-
different types of grounds should be identified ceptacles, and other heavy-current, loads must
and used. As a minimum, the design should be attached to individual grounding brackets
use three ground types: (1) ac returns, (2) dc that are attached to aircraft structure with a
returns, and (3) all others. For distributed proper metal-to-metal bonding attachment.
power systems, the power return point for an This attachment and the surrounding structure
alternative power source would be separated. must provide adequate conductivity to ac-
For example, in a two-ac generator (one on the commodate normal and fault currents of the
right side and the other on the left side) sys- system without creating excessive voltage drop
tem, if the right ac generator were supplying or damage to the structure. At least three fas-
backup power to equipment located in the left teners, located in a triangular or rectangular
side, (left equipment rack) the backup ac pattern, must be used to secure such brackets
f. Grounds for Sensitive Circuits. Spe- be necessary for some objects such as antenna
cial consideration should be given to grounds elements, whose function requires them to be
for sensitive circuits. For example: electrically isolated from the airframe. Such
items should be provided with an alternative
(1) Grounding of a signal circuit means to conduct static charges and/or light-
through a power current lead introduces power ning currents, as appropriate.
current return voltage drop into the signal cir-
cuit. c. Static Bonds. All isolated conducting
parts inside and outside the aircraft, having an
(2) Running power wires too close will area greater than 3 in2 and a linear dimension
cause signal interference. over 3 inches, that are subjected to appreciable
electrostatic charging due to precipitation,
(3) Separately grounding two compo- fluid, or air in motion, should have a mechani-
nents of a transducer system may introduce cally secure electrical connection to the aircraft
ground plane voltage variations into the sys- structure of sufficient conductivity to dissipate
tem. possible static charges. A resistance of less
than 1 ohm when clean and dry will generally
(4) Single point grounds for signal cir- ensure such dissipation on larger objects.
cuits, with such grounds being at the signal Higher resistances are permissible in connect-
source, are often a good way to minimize the ing smaller objects to airframe structure.
effects of EMI, lightning, and other sources of
interference. 11-188. BONDING INSPECTION. In-
spect for the following:
11-187. BONDING. The following bonding
requirements must be considered: a. If there is evidence of electrical arc-
ing, check for intermittent electrical contact
a. Equipment Bonding. Low-impedance between conducting surfaces, that may become
paths to aircraft structure are normally required a part of a ground plane or a current path.
for electronic equipment to provide radio fre- Arcing can be prevented either by bonding, or
quency return circuits and for most electrical by insulation if bonding is not necessary.
equipment to facilitate reduction in EMI. The
cases of components which produce electro- b. The metallic conduit should be
magnetic energy should be grounded to struc- bonded to the aircraft structure at each termi-
ture. To ensure proper operation of electronic nating and break point. The conduit bonding
equipment, it is particularly important to con- strap should be located ahead of the piece of
form the systems installation specification equipment that is connected to the cable wire
when interconnections, bonding, and ground- inside the conduit.
ing are being accomplished.
c. Bond connections should be secure and
b. Metallic Surface Bonding. All con- free from corrosion.
ducting objects on the exterior of the airframe
must be electrically connected to the airframe d. Bonding jumpers should be installed
through mechanical joints, conductive hinges, in such a manner as not to interfere in any way
or bond straps capable of conducting static with the operation of movable components of
charges and lightning strikes. Exceptions may the aircraft.
e. Self-tapping screws should not be used ensure proper operation and suppression of ra-
for bonding purposes. Only standard threaded dio interference from hazards, electrical
screws or bolts of appropriate size should be bonding of equipment must conform to the
used. manufacturers specifications.
h. Bonds must be installed to ensure that k. Use appropriate washers when bond-
the structure and equipment are electrically ing aluminum or copper to dissimilar metallic
stable and free from the hazards of lightning, structures so that any corrosion that may occur
static discharge, electrical shock, etc. To will be on the washer.
Steel, Corrosion Corrosion Re- Cadmium None None Cadmium Corrosion Cadmium
Resisting sisting Steel Plated Steel Plated Steel or Resist Steel Plated Steel
Aluminum
Tinned Copper Terminal and Jumper
Aluminum Cadmium Cadmium Aluminum Aluminum Cadmium Cadmium Cadmium
Alloys Plated Steel Plated Steel Alloy Alloy Plated Steel Plated Steel Plated Steel
or Aluminum
Magnesium
Alloys1
Steel, Corrosion Corrosion Re- Corrosion None None Cadmium Corrosion Corrosion
Resisting sisting Steel Resisting Steel Plated Steel Resisting Resisting
Steel Steel
1
Avoid connecting copper to magnesium.
Magnesium Alloys Cadmium Plated Aluminum Alloy Cadmium Plated Cadmium Plated None or Mag-
Steel Steel Steel or nesium Alloy
Aluminum
Steel, Cadmium Cadmium Plated Corrosion Cadmium Plated Cadmium Plated None
Plated Steel Resisting Steel Steel Steel or
Aluminum
Steel, Corrosion Re- Corrosion Resisting Corrosion Cadmium Plated Cadmium Plated Cadmium
sisting Steel or Cadmium Resisting Steel Steel Steel or Plated Steel
Plated Steel Aluminum
Tinned Copper Terminal and Jumper
Aluminum Alloys Cadmium Plated Aluminum Alloy Cadmium Plated Cadmium Plated Aluminum2
Steel Steel Steel Alloy
Magnesium Alloys1
Steel, Cadmium Cadmium Plated Corrosion Cadmium Plated Cadmium Plated None
Plated Steel Resisting Steel Steel Steel
Steel, Corrosion Corrosion Resisting Corrosion Cadmium Plated Cadmium Plated None
Resisting Steel Resisting Steel Steel Steel
1
Avoid connecting copper to magnesium.
2.
Use washers having a conductive finished treated to prevent corrosion, suggest AN960JD10L
Magnesium Alloys Cadmium Plated Cadmium Plated Magnesium Alloy None or Cadmium Plated
Steel Steel Magnesium alloy Steel or
Aluminum
Steel, Cadmium Cadmium Plated Cadmium Plated Cadmium Plated Cadmium Cadmium Plated
Plated Steel Steel Steel Plated Steel Steel or
Aluminum
Steel, Corrosion Re- Corrosion Resisting Cadmium Plated Corrosion Cadmium Cadmium Plated
sisting Steel or Cadmium Steel Resisting Steel Plated Steel Steel or
Plated Steel Aluminum
Tinned Copper Terminal and Jumper
Aluminum Alloy Cadmium Plated Cadmium Plated Cadmium Plated Aluminum2 Cadmium
Steel Steel Steel Alloy Plated Steel
Magnesium Alloy1
Steel, Cadmium Cadmium Plated Cadmium Plated Cadmium Plated None Cadmium
Plated Steel Steel Steel Plated Steel
Steel, Corrosion Re- Corrosion Resisting Cadmium Plated Corrosion Resisting None Cadmium
sisting Steel or Cadmium Steel Steel Plated Steel
Plated Steel
1
Avoid connecting copper to magnesium.
2.
Use washers having a conductive finished treated to prevent corrosion, suggest AN960JD10L
across each hinge. In any case, not less than ground personnel coming in contact with an
two 6500 circular mil jumpers should be used aircraft after landing. Normally, there is ade-
on each control surface. The installation loca- quate conductivity in the tires for this, but if
tion of these jumpers should be carefully cho- not, a static ground should be applied before
sen to provide a low-impedance shunt for personnel come into contact with the aircraft.
lightning current across the hinge to the struc- Fuel nozzle grounding receptacles should be
ture. When jumpers may be subjected to arc- installed in accordance with the manufac-
ing, substantially larger wire sizes of turers specifications. Grounding receptacles
40,000 circular mils or a larger cross section should provide a means to eliminate the static-
are required to provide protection against mul- induced voltage that might otherwise cause a
tiple strikes. Sharp bends and loops in such spark between a fuel nozzle and fuel tank ac-
jumpers can create susceptibility to breakage cess covers and inlets. In addition, static dis-
when subjected to the inductive forces created charging wicks are installed on wings and tail
by lightning current, and should be avoided. surfaces to discharge static changes while in
flight.
b. Control Cable Lightning Protection
Bonding. To prevent damage to the control 11-196. CLEANING. In order to ensure
system or injury to flight personnel due to proper ground connection conductivity, all
lightning strike, cables and levers coming from paint, primer, anodize coating, grease, and
each control surface should be protected by other foreign material must be carefully re-
one or more bonding jumpers located as close moved from areas that conduct electricity. On
to the control surface as possible. Metal pul- aluminum surfaces, apply chemical surface
leys are considered a satisfactory ground for treatment to the cleaned bare metal surface in
control cables. accordance with the manufacturers instruc-
tions within 4-8 hours, depending on ambient
11-194. LIGHTNING PROTECTION moisture/contaminate content.
FOR ANTENNAS AND AIR DATA
PROBES. Antenna and air data probes that 11-197. HARDWARE ASSEMBLY. De-
are mounted on exterior surfaces within light- tails of bonding connections must be de-
ning strike zones should be provided with a scribed in maintenance manuals and adhered to
means to safely transfer lightning currents to carefully when connections are removed or re-
the airframe, and to prevent hazardous surges placed during maintenance operations. In or-
from being conducted into the airframe via der to avoid corrosion problems and ensure
antenna cables or wire harnesses. Usually, the long-term integrity of the electrical connection,
antenna mounting bolts provide adequate hardware used for this purpose must be as de-
lightning current paths. Surge protectors built fined in these documents or at least be
into antennas or installed in coaxial antenna equivalent in material and surface. Installation
cables or probe wire harnesses will fulfill these of fasteners used in bonded or grounded con-
requirements. Candidate designs should be nections should be made in accordance with
verified by simulated lightning tests in accor- SAE ARP-1870. Threaded fasteners must be
dance with RTCA DO-160C, Section 23. torqued to the level required by SAE
ARP-1928.
11-195. STATIC-DISCHARGE DEVICE.
Means should be provided to bleed accumu- 11-204. [RESERVED.]
11-198.
lated static charges from aircraft prior to
the color should contrast with the wire insula- tion or sleeve.
3 15 15 3
H215A20 H215A20 H215A20
contour of the wire, are heated to the desired pending on equipment configuration, dot ma-
temperature. Wire is pulled through a channel trix can mark wire from 0.037 to 0.5-inch out-
directly underneath the characters. The heat of side diameter. Multi-conductor cable can also
the type set characters transfers the ink from be marked.
the marking foil onto the wire.
11-212. INK JET MARKING. This is a
a. Good marking is obtained only by the non-impact marking method wherein ink
proper combination of temperature, pressure, droplets are electrically charged and then di-
and dwelling. Hot stamp will mark wire with rected onto the moving wire to form the char-
an outside diameter of 0.038 to 0.25-inch. acters. Two basic ink types are available:
thermal cure and UV cure.
b. Before producing hot stamp wire, it
must be assured that the marking machine is a. Thermal cure inks must generally be
properly adjusted to provide the best wire heated in an oven for a length of time after
marking with the least wire insulation deterio- marking to obtain their durability. UV cure
ration. The marking should never create an inks are cured in line much like dot matrix.
indent greater than 10 percent of the insulation
wall. b. Ink jet marks the wire on the fly and
makes a reasonably durable and legible mark
CAUTION: The traditional Hot without damaging the insulation. Ink jets
Stamp method is not recommended normally mark wire from 0.030 to 0.25-inch
for use on wire with outside diameters outside diameter. Multiconductor cable can
of less than 0.035. (REF. SAE also be marked.
ARP5369). Stamping dies may cause
fracture of the insulation wall and 11-213. LASER MARKING. Of the variety
penetration to the conductor of these of laser marking machines, UV lasers are
materials. When various fluids wet proving to be the best. This method marks
these opening in service, arcing and into the surface of the wires insulation without
surface tracking damage wire bun- degradation to its performance. One common
dles. Later in service, when various type of UV laser is referred to as an excimer
fluids have wet these openings, serious laser marker. UV laser produces the most du-
arcing and surface tracking will have rable marks because it marks into the insula-
damaged wire bundles. tion instead of on the surface. However, exci-
mer laser will only mark insulation that con-
11-211. DOT MATRIX MARKING. The tain appropriate percentages of titanium diox-
dot matrix marking is imprinted onto the wire ide (TiO2). The wire can be marked on the fly.
or cable very similar to that of a dot matrix UV can mark from 0.030 to 0.25-inch outside
computer printer. The wire must go through a diameter. The UV laser makes only gray
cleaning process to make sure it is clean and marks and they appear more legible on white
dry for the ink to adhere. Wires marked with or pastel-colored insulation.
dot matrix equipment require a cure consisting
of an UV curing process, which is normally 11-214. IDENTIFICATION SLEEVES.
applied by the marking equipment. This cure Flexible sleeving, either clear or opaque, is
should normally be complete 16 to 24 hours satisfactory for general use. When color-coded
after marking. Dot matrix makes a legible or striped component wire is used as part of a
mark without damaging the insulation. De cable, the identification sleeve should
specify which color is associated with each 11-216. OPERATING CONDITIONS. For
wire identification code. Identification sleeves sleeving exposed to high temperatures (over
are normally used for identifying the following 400 F), materials such as silicone fiberglass
types of wire or cable: should be used.
a. Wires for which identifications are FIGURE 11-26. Standard sleeves (135 C).
reassigned after installation, may be remarked
on sleeves at the termination of each wire
segment. It may be necessary to reidentify
such wires throughout their lengths to facili-
tate ease of maintenance.
FIGURE 11-31. Completed installation. f. Secure each end of clear sleeve with
lacing tape spot tie to prevent loosening of
sleeve.
11-229. [RESERVED.]
11-223.
MS CONNECTOR
N Series Connectors
C Series Connectors
SC Series Connectors
When used as grounding modules, they save 11-233. VOLTAGE AND CURRENT
and reduce hardware installation on the air- RATING. Selected connectors must be rated
craft. Standardized modules are available with for continuous operation under the maximum
wire end grommet seals for environmental ap- combination of ambient temperature and cir-
plications and are track-mounted. Function cuit current load. Hermetic connectors and
module blocks are used to provide an easily connectors used in circuit applications involv-
wired package for environment-resistant ing high-inrush currents should be derated. It
mounting of small resistors, diodes, filters, and is good engineering practice to conduct pre-
suppression networks. In-line terminal junc- liminary testing in any situation where the
tions are sometimes used in lieu of a connector connector is to operate with most or all of its
when only a few wires are terminated and contacts at maximum rated current load. When
when the ability to disconnect the wires is de- wiring is operating with a high conductor tem-
sired. The in-line terminal junction is envi- perature near its rated temperature, connector
ronment-resistant. The terminal junction contact sizes should be suitably rated for the
splice is small and may be tied to the surface circuit load. This may require an increase in
of a wire bundle when approved by the OAM. wire size also. Voltage derating is required
when connectors are used at high altitude in
separate strain relief accessory. Strain relief compound. Preparation and storage of potting
clamps should not impart tension on wires materials should receive special attention.
between the clamp and contact. Careful inspection and handling during all
stages of the connector fabrication until the
f. Slack. Sufficient wire length must be potting compound has fully cured is recom-
provided at connectors to ensure a proper drip mended. Potting compounds selected must not
loop and that there is no strain on termination revert to liquid or become gummy or sticky
after a complete replacement of the connector due to high humidity or contact with chemical
and its contacts. fluids.
moisture in the connectors. A secondary bene- the wire bundle. Clean the areas to be potted
fit of potting is the reduced possibility of with dry solvent and complete the potting op-
breakage between the contact and wire due to eration within 2 hours after this cleaning. Al-
vibration. low the potting compound to cure for 24 hours
at a room temperature of 70 F to 75 F or
a. Connectors specifically designed for carefully placed in a drying oven at 100 F for
potting compounds should be potted to pro- 3 to 4 hours. In all cases follow manufac-
vide environment resistance. An o-ring or turers instructions.
sealed gasket should be included to seal the
interface area of the mated connector. A plas- 11-240. THROUGH BOLTS. Through
tic potting mold, that remains on the connector bolts are sometimes used to make feeder con-
after the potting compounds have cured, nections through bulkheads, fuselage skin, or
should also be considered. To facilitate circuit firewalls. Mounting plates for through bolts
changes, spare wires may be installed to all must be a material that provides the necessary
unused contacts prior to filling the connector fire barrier, insulation, and thermal properties
with potting compound. for the application. Sufficient cross section
should be provided to ensure adequate con-
b. Connect wires to all contacts of the ductivity against overheating. Secure through
connector prior to the application of the pot- bolts mechanically and independently of the
ting compound. Wires that are not to be used terminal mounting nuts, taking particular care
should be long enough to permit splicing at a to avoid dissimilar metals among the terminal
later date. Unused wires should be as shown hardware. During inspection, pay particular
in figure 11-38 and the cut ends capped with attention to the condition of the insulator plate
heat-shrinkable caps or crimped insulated end or spacer and the insulating boot that covers
caps such as the MS 25274 prior to securing to the completed terminal assembly.
11-247. [RESERVED.]
11-241.
11-253. FLEXIBLE CONDUIT. Flexible cutting through the tape. After cutting the
aluminum conduit conforming to Specifica- flexible conduit, the transparent tape should
tion MIL-C-6136 is available in two types: be removed, the frayed braid ends trimmed,
Type I, Bare Flexible Conduit, and Type II, burrs removed from inside the conduit, and
Rubber Covered Flexible Conduit. Flexible coupling nut and ferrule installed. Minimum
brass conduit conforming to Specification acceptable bending radii for flexible conduit
MIL-C-7931 is available and normally used are shown in table 11-24.
instead of flexible aluminum where necessary
to minimize radio interference. Also avail- TABLE 11-24. Minimum bending radii for flexible alu-
able is a plastic flexible tubing. (Reference minum or brass conduit.
MIL-T-8191A.) Flexible conduit may be used Nominal I.D. of conduit Minimum bending radius
(inches) inside (inches)
where it is impractical to use rigid conduit,
3/16 2 1/4
such as areas that have motion between con- 1/4 2 3/4
duit ends or where complex bends are neces- 3/8 3 3/4
1/2 3 3/4
sary. The use of transparent adhesive tape is 5/8 3 3/4
recommended when cutting flexible tubing 3/4 4 1/4
1 5 3/4
with a hacksaw to minimize fraying of the 1 1/4 8
braid. The tape should be centered over the 1 1/2 8 1/4
1 3/4 9
cutting reference mark with the saw 2 9 3/4
2 1/2 10
11-259. [RESERVED.]
11-254.
11-260. GENERAL. Connectors may have perature (greater than 250 C) lacing cord.
one or more contact cavities that are not used. Nylon cable ties are not allowed for this in-
Depending on the connector installation, un- stallation.
used connector contact cavities may need to be
properly sealed to avoid damage to the con- NOTE: Both connectors mating
nector, or have string wire installed. Unused through the engine fire-seal are con-
wires can be secured by tying into a bundle or sidered firewall connectors. Connec-
secured to a permanent structure; individually tors mounted on or near, but not
cut with strands even with insulation; or pre- through, the engine fire-seal are not
insulated closed end connector or 1 inch piece considered firewall connectors.
of insulating tubing folded and tied back. b. Non-firewall Connector Installations.
11-261. QUICK REFERENCE CHART. In this type of installation all unused connector
A quick reference chart of unused connector cavities must also be filled with spare contacts.
contact cavity requirements is given in ta- It is not required, however, to crimp stub wires
ble 11-25. These requirements apply to har- on filling contacts.
ness manufacturing or connector replacement Fill unused contact cavities with spare contacts
only. and Teflon sealing plugs or rods. (See fig-
11-262. UNPRESSURIZED AREA CON- ure 11-40.) Rods shall be cut so that they ex-
NECTORS. Connectors may be installed in tend 1/8 to 1/4 inch beyond the surface of the
unpressurized areas of the aircraft. Unused grommet when bottomed against the end of the
connector contact cavities installed in unpres- spare contact. (See table 11-26 for dimen-
surized areas should be properly sealed as fol- sions.)
lows: 11-263. PRESSURIZED AREAS. Con-
a. Firewall Connectors Installations. nectors installed in pressurized areas of the
Firewall unused connector contact cavities aircraft may be divided into two main installa-
should be filled with spare contacts and stub tion categories, sealed and unsealed.
wires. (See figure 11-39.) a. Sealed connector installations. Sealed
(1) Construct stub wires using high connectors installed in pressurized areas must
temperature wire (260 C). Ensure that stub have their unused contact cavities filled with
wires are of the same type of wires in the bun- Teflon sealing plugs or rods. (See fig-
dle. ure 11-40.) Installation of spare contacts is
optional, except for future wiring addition re-
(2) Crimp the proper contact, for the quirements. (See paragraph 11-234). No stub
connector and cavity being used, onto the wire. wires are required.
Install the crimped contact into the unused
cavity. b. Unsealed Connector Installations. It
is not required to fill unused contact cavities of
(3) Extend stub wires beyond the back unsealed connectors installed in pressurized
of the connector clamp from 1.5 to 6 inches. areas with Teflon sealing plugs or rods. In-
Feather trim stub wires to taper wire bundle. stallation of spare contacts is optional, except
for future wiring addition requirements. (See
(4) Secure wire ends with high tem paragraph 11-234.)
NOTE 2: Stub wires must be of the same type as the other wires of the bundle.
11-270. [RESERVED.]
11-264.
11-271. GENERAL. The electrical and 11-272. SYMBOLS. Only those symbols
electronic symbols shown here are those that associated with aircraft electrical and elec-
are likely to be encountered by the aviation tronic wiring have been listed in general. Re-
maintenance technician. They are in accor- fer to ANSI-Y32.2-1975 for more specific
dance with ANSI-Y32.2-1975. detail on each symbol.
Symbol Meaning
Adjustability Variability
Radiation Indicators
Test-Point Recognition
Polarity Markings
Kind of Current
Envelope Enclosure
Shield Shielding
Symbol Meaning
Resistor
Capacitor
Antenna
Battery
Thermocouple
Ignitor Plug
Symbol Meaning
Transmission Patch
Conductor
Cable
Wiring
Distribution Lines
Transmission Lines
Associated or Future
Symbol Meaning
Waveguide
Termination
Circuit Return
Switching Function
Electrical Contact
Symbol Meaning
Operating Coil
Relay Coil
Switch
Symbol Meaning
Locking Switch
Key-Type Switch
Lever Switch
Symbol Meaning
Safety Interlock
Limit Switch
Sensitive Switch
Flow-Actuated Switch
Symbol Meaning
Temperature-Actuated Switch
Thermostat
Flasher
Self-Interrupting Switch
Foot-Operated Switch
Foot Switch
Symbol Meaning
Governor
Speed Regulator
Relay
Inertia Switch
Mercur Switch
Terminals
Symbol Meaning
Cable Termination
Connector
Disconnecting Device
Test Blocks
Coaxial Connector
Waveguide Flanges
Waveguide Junction
Symbol Meaning
Fuse
Lightning Arrester
Arrester
Gap
Circuit Breaker
Protective Relay
Audible-Signaling Device
Microphone
Symbol Meaning
Handset
Operators Set
Lamp
Visual-Signaling Device
Mechanical Connection
Mechanical Interlock
Mechanical Motion
Clutch Brake
Symbol Meaning
Manual Control
Gyro
Gyroscope
Gyrocompass
Position Indicator
Position Transmitter
Radio Station
Space Station
Integrated Circuit
Amplifiers
Logic Gates
Diode
Transistor Symbols
11-283. [RESERVED.]
11-273.