Basic Functions: Additional Functions: Test:


XS Balance
Switching on Zero Tare Weighing- Levelling, Internal
and off
I
Display Display Applications Adjustment
XP Balance
Display D (Factory setting)
1. Switch on display: Zeroing: Press the Taring: If you work with Choose the applica- 1. Level indicator is built-
Press the On/Off G to set a new a Tare container, first tion: If you want to in in the device.
key briefly. The display zero point. zero the balance. Then change the application,
performs a test and is put the Tare container then press the applica-
then ready to weigh. on the balance and tion menu button and
G press H, to tare choose another ap-
the balance. plication. 2. Level indicator is not
On centered.*
Off
Always use the G
before you start the H
weighing procedure.
2. Switch off Display; 3. Release the clamps.*
Press and hold the
On/Off key until the
message OFF ap- Weighing Setup: For more precision / shorter stability time
pears in the display. Weighing filters: Weighing filters: Weighing filters:
The display then fades
and the balance is
Weighing mode Environment Value Release
switched off.
1. Choose System-Set- 1. Choose System-Set- 1. Choose System-Set- 4. Levelling.After this pro-
up up up cess, lock the clamps
On again.*

Off C C C
2. Define Weighing pa- 2. Define Weighing pa- 2. Define Weighing pa-
rameters rameters rameters
User Profile: *only XP
Choose
5. Internal Adjustment
User Profile
B 3. Define the Weighing 3. Define Environment 3. Define Value Release
This key can be used to mode
Pressing this function
call up the desired user
key triggers a balance
profile.Different settings
adjustment using the
can be stored in a user
built-in calibration
profile.
weight. This can be
implemented at any
time.
Advise: Advise: Advise:
Solids: Fume cupboard un- Highest Precision:
Example
Universal stable weighing table: Very reliable
Unstable,
Powder, Liquid: Very unstable Fast Value Release:
Dosing Very fast,
Stable Weighing table, but less precision
no drafts
Standard, Stable
* depending on balance
METTLER TOLEDO Excellence Plus and Excellence Balances
Overview of the Terminal XP Analytical- and Precision balances:
XP Display Ter-
minal One touch
- change the time
1
1. Button SmartSens: 1
Each of these two
contact-free sensors
6
can be assigned a key 2
or menu function.
7
3 On touch
2. Button Home: 4 - e.g. start the internal adjustment 4
This key can be used 5 8

EXCELLENCE PLUS
to return to theHome
user profile from any
menu level in any
application.

3. Button User profile: 4. Status bar: 5. System-Setup: 7. Button Applications- 8. Printer:


This key can be used If the left or right Define the basic Setup: Pressing this key
to call up the desired SmartSens is as- settings. Each application transmits data via
user profile. Different signed a key func- can be optimized the interface.
settings can be stored tion, then the cor- 6. Select the applica- to the current task
in a user profile. responding symbol tion. using a number of
is highlighted. settings.

Overview of the Terminal XS Analytical- and Precision balances:


XS Display Ter-
minal

1. Button Home:
This key can be used
to return to theHome
user profile from any
On touch
menu level in any 1 - e.g. start the internal adjustment 3
application.

2 4
2. Weighing application:
By pressing this symbol
you can choose the
desired application.

3. Button Applications-
Setup:
Each application can 4. Printer:
be ideally adapted to Pressing this key
the current task using transmits data via
a number of settings. the interface.

Mettler-Toledo AG 2008 11781027 Printed in Switzerland 0807/7.12 *11781027*