5/14/2014 Summary

FRAMEWORKAGREEMENT:SCHEDULEOFRATES

Project: ConstructionofTriqitTalja,Swieqi
FileNo: RD156/14
ContractNo:

ContractSummarySheet
Item Description Amount()
inclusiveofVAT,EcoContribution
andallother/taxesasmaybe
applicable
0.000 Preliminaries
1.000 GeneralSiteClearance&DemolitionWorks
2.000 Earthworks&RoadFormation
3.000 TrenchExcavation&BackfillingWorks
4.000 InstallationofBuriedInfrastructure(Electrical)
5.000 InstallationofBuriedInfrastructure(PotableWater/WasteWater)
6.000 ServiceUtilities
7.000 StormWaterNetwork
8.000 Kerbs & Paving
Kerbs&Paving
9.000 WallConstructionWorks
10.000 AsphaltWorks
11.000 TrafficLights/PelicanCrossings&BelishaPoles
12.000 StructuralConcreteWorks
13.000 MiscellaneousWorks
14.000 DayWorks
15.000 StructuralRepairWorks
16.000 EmergencyWorks
SUBTOTAL:

17.000 WSC
18.000 WSCD
TOTAL:

Page1of7
Printdate: TrafficManagement+
5/14/2014 SiteSafety

FRAMEWORKAGREEMENT:SCHEDULEOFRATES

ITEM DESCRIPTION

ExpectedLevelofTrafficManagementanditscompensation,shallbeasindicatedintheContractAllocationandsubsequentWorkOrders.
Payments shall be carried out as per cl. 4.2.1 Volume 4. The below list indicates Traffic Management and Site Safety equipment which the contractor is expected
tohaveathisavailabilitytoaccomodatetheTrafficManagementandSiteSafetyrequirmentsrequestedbytheContractingAuthority.
0.000 TrafficManagement&SiteSafety
A VerticalSignage:
The rate shall include for the graphical design and related submissions to the requirements as described herein. The graphical design details shall comply
1 Note: with the equivalent diagram number of the UK TSRGD / TSM (or to an equivalent reputable national traffic sign regulation of an EU member state. This
equivalentregulationmustbedeclaredandsubmittedtoTransportMaltaforapprovalpriortothefabricationofthesigns).
Retroreflective triangular, round or octagonal traffic signs, Class RA3 (microprismatic DIN 675204, Table 3 or equivalent). Rate shall include for the
2 0.001
temporarysupportingposts(heightasrequired)weightedtobalanceasnecessary.RateapplicabletoSignsasperitem(a.)to(n.)below:
3 0.001a. "MenatWork"TriangularSignSize900mm;
4 0.001b. "NoEntry"RoundSignSize600mm;
5 0.001c. "NoEntry"RoundSignSize900mm;
6 0.001d. "NoLeftTurning"/"NoRightTurning"RoundSize600mm;
7 0.001e. "NoLeftTurning"/"NoRightTurning"RoundSize900mm;
8 0.001f. "WhiteonBlueArrow"RoundSignSize900mm;
9 0.001g. "LooseChippings"TriangularSignSize900mm;
10 0.001h. "LaneNarrows"TriangularSignSize900mm;
11 0.001i. "STOP"OctagonalSignSize900mm;
12 0.001j. "SLOW"RoundSignSize900mm;
13 0.001k. "SpeedLimit"RoundSignSize900mm;
14 0.001l. "NoUTurn"CircularSign900mm;
15 0.001m. "HeightLimit"RoundSign900mm;
16 0.001n. "NoParking"CircularSign900mm.
Retroreflective rectangular / square, Class RA3 (microprismatic DIN 675204, Table 3 or equivalent). Rate shall include for the temporary supporting posts
17 0.002
(heightasrequired)weightedtobalanceasnecessary.RateapplicabletoSignsasperitem(a.)to(p.)below.
18 0.002a. "25m","50m","100m","200m"(supplementaryplate)distancesign0.27mx0.80m
19 0.002b. "NoEntryExceptforResidents&toRenderService"Size0.60mx0.9m(minimumdimensions)
20 0.002c. "NoEntryExceptforPublicTransport"Size0.60mx0.9m(minimumdimensions)
21 0.002d. "RoadWorksAhead,ReduceSpeedNow"SignSize0.6mx0.9m(minimumdimensions)
22 0.002e. "ConstructionSiteKeepOut"Sign0.6mx0.9m(minimumdimension),drawingrefFM19
23 0.002f. "SiteSafety"Sign0.6mx0.9m(minimumdimension),drawingrefFM19
24 0.002g. "RAMP"Sign,drawingrefFM19
25 0.002h. "STOPRoadClosed"Sign0.6mx0.9m(minimumdimension),drawingrefFM19
26 0.002i. "TrafficControlAhead"RedSign0.6mx0.9m(minimumdimensions)
27 0.002j. "Diversion"(includingleft/rightarrow)YellowSign
28 0.002k. "Pedestrians"(includingleft/rightarrow)BlueSign
29 0.002l. "RoadWorksAhead"YellowSign0.6mx0.9m(minimumdimensions)
30 0.002m. "TemporaryTrafficLightsAhead"YellowSign0.6mx0.9m(minimumdimensions)
31 0.002n. "RoadConstructionAhead"RedSign0.6mx0.9m(minimumdimensions)
32 0.002o. "FindAlternativeRoute"YellowSign0.6mx0.9m(minimumdimensions)
33 0.002p. "PedestrianCrossings"whiteonblueSign
34 B TRANSPORTMALTASIGNS
2.00m x 1.25m "This Road was Resurfaced by Transport Malta" Sign, inclusive of supporting posts (height as required) weighted to balance as necessary,
35 0.003
drawingrefFM17.
2.00m x 1.25m "This is a Transport Malta Project" Sign, inclusive of supporting posts (height as required) weighted to balance as necessary, drawing ref FM
36 0.004
17.
2.00mx1.25m"Binita'ToroqResidenzjali"Sign,inclusiveofsupportingposts(heightasrequired)weightedtobalanceasnecessary,drawingrefFM18.
37 0.005

38 0.006 2.00mx1.25mTM/ContractorSign,inclusiveofsupportingposts(heightasrequired)weightedtobalanceasnecessary,drawingrefFM18.
39 0.007 Supply,transport,installandremoveSiteSpecificSign toamaximumsizeof2.00mx1.25m.WordingonsignasdirectedbyOfficerinCharge.
40 C TrafficSafety&ControlEquipment
41 0.008 ReflectiveConewithbase,minimumheight18".
42 0.009 OrangeSafetyFenceBarrierwithposts,1.20mhighminimum.
43 0.010 Cautionredandwhitetape(LDPE),3"6"wide,fixedtopostsasnecessary.
44 0.011 ParadeBarricade(plasticormetal).
45 0.012 DCellFlasherwithBattery(Amber).
46 0.013 Temporarymetalhoardingfence(minimumheight2.10m).Includingsupportingposts.
47 0.014 Coveringtohoardingwithgreennetting.Rateistoincluderemovalatcompletionandmaintenanceasnecessary.
48 0.015 Red/White(alternate)Plasticbarriers.
49 0.016 Delineatorstripswithreflectors.
50 0.017 ConcreteJerseyBarriers.
TemporaryMobileTrafficLightSet(Red/Amber/Green)inworkingorderincludingelectricalsupply/powersourceandmountingarrangement.
51 0.018

Page2of7
Printdate: TrafficManagement+
5/14/2014 SiteSafety

FRAMEWORKAGREEMENT:SCHEDULEOFRATES

52 D HorizontalSignage
53 Note: Measure,temporarilymark,setout,supplyandlayretroreflectiveroadmarkingsfortemporarypurpose.
54 0.019 100mmwidewhite/yellowlinemarkingtemporaryroadtape.
55 0.020 100mmwidedoubleyellowlinemarking.
56 0.021 100mmwideyellow/whitelinemarking.
Apply roadmarkings for temporary Pedestrian Crossing to the UK Zebra, Pelican and Puffin Pedestrian Crossings Regulations and General Directions (inc.
57 0.022
Amendments)andTransportMaltaspecificationSeries1200tothetypicallayoutasshownintheUKTSM5Figure151.
58 0.023 Diag.1002.1(Stopline),400mmwide.
59 0.024 "STOP",1600mmasperUKTSRGD,Schedule13.VI.
60 0.025 Diag.1022,"SLOW",1600mmasperUKTSRGD,Schedule13.VI.
61 E Miscellenous
62 0.026 Temporarypedestrianbridgewithrailing,atleast1.0mwide.
63 0.027 Temporarymetalplatetotaketrafficloading,maximumdimension2.0mx2.0m.
64 0.028 LightScarifyoverexistingsurfacetoremovehorizontalsignage
65 0.029 Paintinblackoverexistingsurface
Supply and apply hazard marker paint (yellow / black) on structures (tunnel portals, columns, arches) TSRGD Diagram 530.2 in yellow (retroreflective >
66 0.030 100mcd) and black bands to the dimensions indicated. Rate to include for the surface preparation, minor edge repairs (infilling with proprietary high
strengthconcreterepairmortar)primingofsurfaceandlifting/hoisting/workingplatform.
Portable LED VMS Sign Outdoor Usage inclusive of Electrical Supply / Power Source in either character / line and or full matrix (pictorial message) at one time
67 0.031
toEN12966asbelow,includingmountingarrangements
69 i Singlecolourlineorcharactermatrix
70 ii. FixedLEDpictogramandtext
0.032 FLOODLIGHTSincludingnecessaryhaulingandliftingequipment.
77 0.033 Crossoverexistingsignwithredadhesivetapeandremoveasnecessary.
78 0.034 SafetyCoverexistingsignwithleatherbag(anysize)andremoveasnecessary.
78 SUBTOTAL0(CARRIEDTOSUMMARYSHEET) 0 0.00 0

Page3of7
Printdate: FrameworkAgreement2013
5/14/2014

FRAMEWORKAGREEMENT:SCHEDULEOFRATES

ITEM DESCRIPTION QTY UNIT RATE Amountincl.VAT

0.000 Preliminaries
0.000 Implementingandoperatingtrafficmanagementprovisions:
for works classified as per TM B defined in second schedule of LN 29 of
a. 1.00 No.
2010
for works classified as per TM C defined in second schedule of LN 29 of
b. 2.00 No.
2010perworkdayuptoamaximumof1400.00.
0.080 Takeupexistingwallandcartaway 20.00 sq.m
TotalBill0.000toSummarySheet: Euro
1.000 GeneralSiteClearance&DemolitionWorks
Breaking up of existing concrete kerbs including concrete footing and
1.013 100.00 mrun
backing.
Breakingupofexistingconcretepaving/blocks/slabsinfootways.
1.015 120.00 sqm
Clearing of road surface from debris and other overlying material as
1.023 20.00 cum
instructed.
TotalBill1.000toSummarySheet: Euro
2.000 Earthworks&RoadFormation
A ExcavationWorks
Oversite excavation in any type of ground using planar equipment to
2.001 300.00 cum
reducelevels.
Oversite excavation in any type of ground using mechanical equipment to
2.002 50.00 cum
reducelevels.
B FillingWorks
Type 1 Subbase material as per series 800, cl. 803; Nominal grain size
37.5mm, hardstone (>50KN on 10% fines value in wet condition), in filling
2.003 120.00 cum
to make up levels, leveling and compacting in layers (max. thickness
300mm)asrequired.Materialistobecompactedatomc.
C MiscellaneousWorks
Modifying &/or Raising/Lowering the level of Gratings and Manhole
2.010 5.00 no.
Coversandtherespectiveframes.
TotalBill2.000toSummarySheet: Euro
3.000 TrenchExcavation&BackfillingWorks
A TrenchExcavationWorks
Excavate by hand tools or compressor in any type of material, to any
3.006 5.00 cum
depth,includingworkingaroundexistingburiedinfastructure.
TotalBill3.000toSummarySheet: Euro
InstallationofBuriedInfrastructure(PotableWater/
5.000
WasteWater)
B PotableWaterHouseServices
POLYETHYLENEPIPESANDFITTINGSPROVIDEDBYOTHERS.
Excavation around pipe perpendicular to the trench for installation of
5.003 9.00 no.
tapping.Installationoftappingtobecarriedoutbyothers.

Page 4 of 7
Printdate: FrameworkAgreement2013
5/14/2014

FRAMEWORKAGREEMENT:SCHEDULEOFRATES

ITEM DESCRIPTION QTY UNIT RATE Amountincl.VAT

Excavate trench by pneumatic hammer for house service between water


main and house frontage. If applicable works are also to include for the
cutting of bituminous road surface to its full depth, (on both sides of
trench) with straight edges parallel to line of trench and for edge sealants
for any extra length of cut. Collect pipes, fittings and stop cock covers
from store, load, transport to site and unload and lay PE (polyethylene)
5.005 60.00 mrun
pipes for house service inclusive of fittings. Rate also includes for the
construction of stopcock chamber complere including the fixing of cover
and frame. Chase in wall along consumer's premises and plaster after
installation of service pipe. Supply, ram and compact lean concrete (as
per Series 2600, Clause 2603) around water main up to support pipe and
toroadformationlevelovertrench/pitsforhouseservice.
5.006 ShiftOnlywatermeters,excludingpipework. 9.00 no.
Extra Over the installation of house services to allow for additional work
5.008 45.00 mrun
invlovedinpipesleevingofhouseservices,inclusiveofductingsleeve.
C TemporaryPotableWaterSupply
POLYETHYLENEPIPESANDFITTINGSPROVIDEDBYOTHERS.
Sluice Valve chamber, complete including 5" diameter uPVC pipe over
sluice valve, concrete surround and cover, all as directed by engineer.
5.012 10.00 no.
(Cast iron covers to be supplied by others and collected from stores by
contractor).
F WasteWaterManholes&Covers
Modify existing house intercepting trap chamber by lowering or raising
the Reinforced concrete slab to the required site levels, including all
5.025 necessary works and the provision of new precast reinforced concrete 10.00 no.
cover slabs size approximate 300mm x 600mm x 75mm thick when
required.
TotalBill5.000toSummarySheet: Euro
6.000 ServiceUtilities
A DuctsandCulverts
6.011 1x50mmdiameterupvcpipelightgaugecastinfootpaths. 75.00 mrun
6.012 1x110mmdiameterupvclightgaugecastinfootpaths. 30.00 mrun
B Drawpits&Covers
Steel B125 junction boxes including cover and frame, size 300mm x
300mm and not exceeding 750mm deep cast in footways, including all
6.015 4.00 no.
necessary excavtion in any type of ground, 150mm thick C20 concrete
surround,formworkandbackfilling.
TotalBill6.000toSummarySheet: Euro
7.000 StormWaterNetwork
A uPVCpipesandfittings
uPVC pipes and fittings to BS EN 1401:1998 Type UNI 303/2 and with

7.001 Class Rigidity SN4 SDR 51 in trenches, laid to the proper gradient and

alignmentwithsuitableapprovedjoints;withthefollowingdiameters:
a. 110mmdiameter 30.00 mrun

Page 5 of 7
Printdate: FrameworkAgreement2013
5/14/2014

FRAMEWORKAGREEMENT:SCHEDULEOFRATES

ITEM DESCRIPTION QTY UNIT RATE Amountincl.VAT

8.000 FootpathWorks
A Kerbs&Paving
Precast concrete kerb 255mm high x 1000mm long, laid straight or
curved on plan to a radius exceeding 12m, including all necessary saw
8.001 cutting and excavation or trenching as necessary in existing ground, 120.00 mrun
bedding and backing with insitu unreinforced concrete grade C15,
pointingofjoints,completeallasperdetailRCD1100/1.
Cast insitu C20 concrete in gutter 200mm wide x 150mm deep, straight
8.003 or curved to any radius including all necessary formwork and ancillary 145.00 mrun
works,finishedsmooth.
Cast insitu C20 concrete in footpaths, 100mm thick; laid to levels, falls
and/or cross falls, including expansion joints at 5m centres brush surface
8.005 140.00 sqm
finish and including making up levels with infill material and compacted,
allasperRCD1100/5.
C MiscellaneousWorks
Galvanised steel grating class B125, 120mm wide in footpaths, including
8.020 15.00 mrun
pvcUchannel,castinconcreteandC20concretesurroundasnecessary.
TotalBill8.000toSummarySheet: Euro
9.000 WallConstructionWorks
C StandardSizedBlockWalls
SoftstoneWalls
230mm thick softstone walls fairfaced both sides, bedded, jointed and
9.012 25.00 sqm
pointedincement:xahxmortar;aboveDPC.
MiscellaneousWorks
9.025 DPCmembrane,horizontaland/orverticaltowalls. 40.00 sqm
TotalBill9.000toSummarySheet: Euro
10.000 AsphaltWorks
Note:AllRoadPavementshallcomplytoseries700and900;ingeneral,unlessotherwisespecified.Surfacetolerancesshallbeaccording
A Asphaltroadpavingworksandtrenchreinstatement
Cutexistingroadsurfaceusingrotarysaw,depthnotexceeding100mm.
10.001 18.00 mrun
Hot dense bituminous paving mixture in accordance to ASTM D3515 and
approved mix designs, including for the necessary bitumen required as
10.003
per ASTM D3515 and approved mix design, and the painting of the
verticaledgesofanyjointswithhotbitumen:
0/19 mm for Binder Course 60mm thick in carriage way, hard shoulder
b. and hardstrip, compaction degree: 97%; laid to comply to 660.00 sqm
requirementsincl.901and904.
0/12.5 mm for Wearing Course 40mm thick in carriage way, hard
d. shoulder and hardstrip, compaction degree: 97%, EN 126976, Proc. B;
laidtocomplytorequirementsincl.901and906.
ii. usingaggregatewithaLosAngelesvalue20andPSV53 660.00 sqm
10.004 Workingaroundprojections. 5.00 no.
10.005 Tackcoattosurfacestoreceivebituminouspavingmixture. 660.00 sqm

Page 6 of 7
Printdate: FrameworkAgreement2013
5/14/2014

FRAMEWORKAGREEMENT:SCHEDULEOFRATES

ITEM DESCRIPTION QTY UNIT RATE Amountincl.VAT

Penetration grade bitumen as joint sealant to open joints as directed by


10.006
theengineerorotherapprovedequivalent:
a. upto25mmwide 150.00 mrun
TotalBill10.000toSummarySheet: Euro
12.000 StructuralConcreteWorks
A Castinsituconcrete
Cast insitu concrete, generally, including laying, compacting and finishing
12.001
offforthefollowinggrades:
c. C20 15.00 cu.m
TotalBill12.000toSummarySheet: Euro

Page 7 of 7