3.2.2. 2 Mbit/s (120 ohm) connections.

Insert the module into the slot assigned to it.

Wire the 2 Mbit/s signals onto module using the SUB.D 37 P male connector (1AB 00311024).

Close the connector into the relevant SUB.D 37 Shell connector (1AB 006030065)

The SUB.D 37 P connector and shell are inside the 120 ohm new Connector Kit (3AL80834AAAA)

SUB.D 37P male connector


1AB 0031024

Tx Rx
white
37 19
blue white
1 quad turquoise blue
violet turquoise 1 quad
1 quad
white violet
orange white
cable 2 quad turquoise orange
cable
shielded violet turquoise 2 2quad
quad
white violet shielded
4 symmetrical
green white 4 symmetrical
quads turquoise
3 quad green quads
violet turquoise 3 quad
white violet
brown white
4 quad turquoise brown
violet turquoise 4 quad
violet

20 1

Connection side wiew

N.B. This figure can change if a different cable is used.

N.B.1 If the correct colours are used, its possible to avoid the label for each wire. Its enough to label the
cable.
Figure 10. 7x2 Mbit/s (120 ohm) physical connection (T1-T3)

ED 01it02

3AL98061AAAA 20/69
Figure 11. 21x2 Mbit/s (120 ohm ) Module connections

ED 01it02

3AL98061AAAA 21/69