Académique Documents
Professionnel Documents
Culture Documents
ii
Reactor Blocks in ProMax ............................................................................................. 50
Gibbs Minimization Reactors .................................................................................. 51
Exercise 27: Incinerator/Fired-Boiler, Gibbs Minimization Reactor ................ 52
Equilibrium Reactor Blocks in ProMax................................................................... 53
Exercise 28: Steam Methane Reforming (SMR), Equilibrium Reactor ............ 54
Exercise 29: COS Hydrolysis in an Equilibrium Reactor .................................. 55
Conversion Reactor Blocks in ProMax.................................................................... 56
Exercise 30: HF Alkylation using a Conversion Reactor .................................. 57
Exercise 31: Defining a Catalytic Reaction Set ................................................. 58
Plug Flow Reactor Blocks in ProMax ..................................................................... 59
Exercise 32: Water Shift Reactors, Plug Flow Reactor ..................................... 60
Stirred Tank Reactor Blocks in ProMax .................................................................. 61
Exercise 33: Allyl Chloride Production in CSTR and PFR Reactors ................ 62
iii
iv
ProMax Level IIAdvanced Simulation Methods Agenda
Day 1 Customizing ProMax
Modifying the Options.xml File
Modifying Column Hardware.xml File
Modifying Pipe Segment Data.xml File
Creating additional personalized stencils
Creating personalized watermarks
Property Stencils and Examples
Adding the Property Stencils to your ProMax project
Recycles/Solvers and Prioritization
Techniques for improved solve time
Troubleshooting
Exchanger Ratings
HEX Rating
v
Customizing ProMax
ProMax offers many different methods to customize it to your particular needs and
usages. Several XML files are available to modify many options of ProMax,
personalized stencils may be created allowing for easy drag-and-drop placement of
complex units, watermarks can be customized, and binary interaction parameters can be
calculated and modified based on any additional information you may have available.
1
Exercise 1: Add New Property to Process Streams
Modify your Options.xml file to include the Normal Volumetric Flow Rate as a default
value shown in the Project Viewer for all PStreams.
Hint: most properties are used at some point in the Options.xml file and can be found
by searching the document. If a property is not available in the XML file, all properties
and their respective enumeration strings are listed in the VBA Object Browser. You
can access this from ProMax by going to the Tools menu, then selective Macros
and Visual Basic Editor from the options listed. Once this opens, you can then find
the object browser under the View menu. In the list of Classes, scroll to
pmxPhasePropEnum to find the list of Phase Property enumeration strings (e.g.,
pmxPhaseMassCp for the Mass Cp value).
2
Modifying Column Hardware.xml File
Similar to the Options.xml file, the Column Hardware.xml file allows further
customization and additions to ProMax. Specifically, the options provided with this file
include:
Customizing structured and random packing materials
Modifying many parameters, including those seen in the sample code below:
<Item
Name="pmxRandomPackingTypesEnum">pmxRandomPackUserDefined</Item>
<Item Name="pmxPackingMaterialTypesEnum">pmxPackingMaterialMetal</Item>
<Item Name="pmxRandomPackingFactor">130.0</Item>
<Item Name="pmxRandomPackingSurfaceArea">101.7060367</Item>
<Item Name="pmxRandomPackingVoidFraction">0.965</Item>
<Item Name="Nominal Diameter">0.0508</Item>
<Item Name="Billet Cfl">1.61</Item>
<Item Name="Billet Cp">0.75</Item>
<Item Name="Billet Ch">0.784</Item>
<Item Name="Billet CL">1.218</Item>
<Item Name="Billet Cv">0.362</Item>
<Item
Name="pmxStructuredPackingTypesEnum">pmxStructPackUserDefined</Item>
<Item Name="pmxPackingMaterialTypesEnum">pmxPackingMaterialMetal</Item>
<Item Name="pmxStructuredPackingFloodModelEnum">
pmxStructuredPackFloodModelBilletSchultes</Item>
<Item Name="pmxStructuredPackingSurfaceArea">250</Item>
<Item Name="pmxStructuredPackingVoidFraction">0.988</Item>
<Item Name="Billet Cfl">2.464</Item>
<Item Name="Billet Cp">0.292</Item>
<Item Name="Billet Ch">0.554</Item>
<Item Name="Billet CL">1.068</Item>
<Item Name="Billet Cv">0.406</Item>
3
Modifying Pipe Segment Data.xml File
Similar to the Options.xml and Column Hardware.xml files, the Pipe Segment
Data.xml file allows further customization and additions to ProMax. Specifically, the
options provided with this file include:
New fittings and their resistance coefficients
New ground type and their diffusivity
New insulation types and their thermal conductivity
Note: the ID number points ProMax to specific information in its database. When
modifying any item, the ID must be deleted.
- <Type Name="pmxPSFittingType">
- <Type Name="pmxPSGroundType">
- <Type Name="pmxPSInsulationType">
4
Creating Additional Personalized Stencils
Creating a Custom Stencil
1. From the file menu, choose Shapes and select New Stencil to have it added to
your current ProMax file.
2. Select the icons you wish to store in the new stencil and drag the grouping to the
new stencil.
3. Right click on the stencil heading and select Save As and choose the location
and name for the custom stencil.
4. Close the ProMax file.
5. Open Visio and select the Stencil1.vss file just created.
6. From the Visio menu, select save again to ensure a disconnect from ProMax and
close Visio.
7. You can now add this new stencil to any ProMax file and use the drawing
objects as needed. From the file menu, select Shapes, Open Stencil and browse
to the stored location of the stencil.
8. Simply drag your new objects to the drawing page and redefine.
9. Only the objects, streams, and number of stages inside columns will be retained.
10. All numbering will be original and automatic as determined by ProMax. No
previous labels will be used.
5
Creating Personalized Watermarks
ProMax allows for customization of the watermark. You can remove the Bryan
Research & Engineering watermark and have no remaining background picture, or you
may add your own picture instead.
1. Go to the Background page of the project, typically the last sheet tab at the
bottom of the Visio page.
2. Right click anywhere on the Background page and choose View, then Layer
Properties
3. De-selecting Visible and Print will disable the watermark, but allow it to later
be re-enabled through the same process.
4. If you wish to permanently delete the Bryan Research & Engineering watermark
from this project, select the Watermark layer, and click on the Remove button.
5. If you would like to add your own watermark to the page, any picture placed on the
page will be shown on all other pages. To add a picture, click on the Insert menu
item, then insert, picture, and from file, then browse to the picture you would
like inserted.
6. To change the transparency of the newly added picture, right click on the object,
select Format, then Picture. On the Image Control tab is an effect
Transparency.
7. This must be done for each project you wish to change the watermark on.
8. To apply a change for all newly created ProMax projects, a template file must be
changed in a similar manner. This template file is found by default in the folder
C:\Program Files\Bryan Research & Engineering Inc\ProMax2\Templates
o The template file is Project-A.vst for US customers.
o The template file is Project-A4.vst for those customers using the A4 size
paper.
o Once you have created the file you would like to use, save it as a .vst file and
replace the Project-A.vst or Project-A4.vst file in the Templates folder.
o Note: new upgrades and releases of ProMax will override these changes.
Please keep an additional copy of your modification for future use in a
separate location.
6
Property Stencils and Examples
The following property stencils are included with your installation of ProMax, however
are not loaded by default. These provide some extended capabilities of ProMax, and
can be loaded by following these steps:
Note: in the same folder is also an MHT file. This file is a help file associated with the
property stencil.
There are several Property Calculator examples shipped within the ProMax Property
Stencil. In this collection, most of the objects function as is while the Solver/Specifier
Example requires the addition of a small amount of VBScript code. These examples are
as follows:
Property Input
Allows input (when shape is selected) of editable ProMax properties
directly from PFD
Property Connector
The Property Connector shape is a visual representation of data
sharing between shapes. It displays no data itself, but transfers its
moniker to another shape. There is no VBScript required for the
Connector shape. It adds its property to a connected Property
Calculator grid, or the one allowed property for the other basic shape
types. The Connector property contains a partial moniker, called an
offset, selectable via the Object Tree. The remainder of the moniker
comes from the attached block or stream. A moved or copied
connector retains its offset moniker and when attached to a similar
ProMax object will retrieve the same property from the attached
object with no additional user interaction.
7
Property Calculator
This shape displays properties that are calculated from other ProMax
Objects. Unlike the other basic shapes, the user may add multiple
ProMax properties and local variables. Using VBScript, custom
calculations are made, displayed, and even returned to ProMax during
Solve (via ProMax Calculators). All example shapes (below) are
Property Calculators to which BR&E added VBScript and dropped
back to the Stencil for later use. These example shapes perform
calculations that are mostly unavailable in ProMax and serve as
VBScript examples. Refer to these example shapes and the project
file Property Stencil Demonstration - Simple Gas Plant.pmx when
customizing this basic Property Calculator shape.
8
Data Exchange
This Property Calculator example exchanges a ProMax property
between ProMax and an embedded Excel workbook in a bidirectional
manner. A new Data Exchange connected to a Property Connector
that has a defined moniker offset and is connected to a block or stream
preselects the property moniker in the Edit Variable dialog. The
OK button is still required to display the Select ProMax Excel
Workbook Range dialog. Selecting cells with the mouse updates the
input box on this dialog.
Solver/Specifier Example
This Property Calculator example is a shell that with appropriate
VBScript edits supplies a value to a script based ProMax Calculator
(Solver or Specifier).
1. Create a new ProMax calculator for the input variable you
want to control. You will enter the Measured Variables in the
Stencil dialog rather than on the calculator dialog.
2. In the Property Calculator Edit dialog, modify the moniker of
CalcSource to reference the target ProMax Calculator
Source.
3. Add Measured Variables to the grid that reference the required
properties; then press Edit Script Function.
4. Use the added measured variables to design the Specifier value
function, or the Solver residual error function and place this
formula in the VBScript in place of the number 1 next to the
comment Assign value to calculator.
Cn+ Flow/Frac
This Property Calculator example displays the flow or fraction sum of
Cn+ compounds in a process stream. This has a similar behavior to
the Cn+GPM calculation but has a user selectable composition basis
accessible through the Edit dialog.
9
Flow Duplicator Example
This Property Calculator transfers a process streams composition and
sets the flow from one connected stream to the other. The Property
connector with the double arrow connects to the stream from which
the composition is desired. The other Property connector designates
the stream to be set. Solver priority, flow basis and flow specification
are set via the Edit dialog. Only when a valid destination stream is
connected can the flow specification be set (via the Edit dialog or
direct entry in the shape). Disconnection of the destination stream
resets the flow rate.
UA Wizard
This Property Calculator example offers the user the capability to
control heat exchanger performance. UA, minimum approach, LMTD
and %OD may be targeted by controlling outlet stream conditions or
unit duty. The tool queries the user for key decisions and
automatically sets up a Simple ProMax Calculator when connected to
a heat-integrated exchanger or separator.
[Cn+] Solver
This example sums the flow or fraction of compounds containing n
or more carbon atoms in a process stream to drive a script based
ProMax Solver. The Property Connector defines the process stream to
use in the calculation. The predefined Simple solver is linked to the
shape via the dialog that appears on drop or double clicks.
10
Pipeline Mach Example
Connect this example to a pipeline to display the maximum fluid
Mach number. If a user set flow exists on the inlet or outlet process
streams, a script based ProMax Solver is automatically setup to drive
the maximum fluid Mach number to the value defined in
TargetMach. Alternatively, a predefined script based ProMax
solver may be linked to this property solver using the menu that
appears after double clicking on the shape.
Orifice Plate
Hybrid of a Property calculator and a JT Valve
Membrane
The membrane tool in the ProMax Property Stencil is a block that
simulates an asynchronous vapor phase separation. This simplified
model operates irrespective of equipment geometry. The tool
provides the ability to perform a separation based on fixed total area,
or to solve for the area given desired separation constraints.
Permeability data (selectivity) is dependent on the polymer employed
and its thickness. Consult patent, literature or vendor references for
the most appropriate values.
11
Recycles/Solvers and Prioritization
Both recycles and solvers used in ProMax have an associated priority value. This value
determines the order in which ProMax attempts to solve any nested or dependent
recycles and solvers.
Recycles
o Each ProMax recycle, whether material or energy, is defined as a solver
based on its function.
o By default, each recycle is assigned a priority of 1 when placed on the
drawing page.
o The user must then take control of the proper prioritization for each
recycle to solve most efficiently.
User-defined Solvers
o Each solver defined by the user also has a priority.
o By default each user defined solver is assigned a value of 0 upon
creation.
o The user also has the ability to define the priority of these solvers to help
obtain the most efficient solution.
Troubleshooting
o The priority is determined by the highest value assigned; the higher the
numerical value, the higher the priority.
o ProMax looks only at relative values, therefore numbers can be skipped.
For example, all priorities on the first flowsheet can be numbered in the
400s, the second flowsheet in the 300s, etc
o It is usually best to solve the inner loop dependent solvers first and then
work your way out. This may not always be the case.
o A Grouping function is available to have a group of solvers evaluated
simultaneously since several solvers may have shared dependencies.
12
Exercise 7: Simple Example Demonstrating Prioritization
Concept
Open the project named Recycle and Solver Priority Example from the solved folder
to illustrate these principles.
13
Exercise 8: Prioritization of a Large Multi-Flowsheet Plant
Open Exercise 8 Prioritization of a Large Multi-Flowsheet Plant from the training
session files. Find a sensible order for the simulation to solve its calculators and
recycles. This plant contains a DEA Amine Unit, two Claus Trains, an MDEA tail gas
clean up unit and an incinerator. Depending on the priorities of the recycles and the
calculators included in this simulation, the solve time can range from many hours to
only a few minutes.
14
User Value Sets
A user value is typically a property defined by the user which is not available in
ProMax, but can also be a reference value, composition or property
A user value set can contain a single user value or multiple user values.
User values can be assigned a short moniker, and can be used in calculators or
displayed in property tables, and can be included in a ProMax Report.
The user value is defined using a simple specifier to relate properties or to set a
reference value.
15
Displaying a User Value in a Property Table
User values can be displayed in a property table. Although it is not necessary to
specify a short moniker for the user value, it is much more convenient to use a
short descriptive name rather than the very long full moniker for the property.
To generate a short moniker, open the user value set dialog in the Project
Viewer and right-click the blue parameter field for the user value of interest.
Select "Add to Short Moniker List" from the pop-up menu.
In the short moniker dialog, type a short moniker in the field at the bottom and
click the Add/Reset Short Moniker button.
Drag a property table from the ProMax Streams stencils and place on the flow
sheet.
Double-click the property table to open the dialog, and in the lower left corner
of the dialog, click the Moniker radio button and leave the short moniker
check box selected. Available selections will include all short monikers for the
project. Select the short moniker you want displayed in the property table by
clicking on it and clicking the arrow button to transfer to the displayed
selections. Click OK to exit the property table dialog.
16
User Value Set Problems:
The following three exercises all reference the previously solved Exercise 8:
Prioritization of Large Multi-Flowsheet Plant
1. Select the Amine Unit simulation with the reboiler being heated by utility steam.
2. To create a user value set, open the Project Viewer and right click on the User
Value Sets item in the navigation tree on the left side, and click "Add..."
3. In the User Value Set dialog, click the Add... button at the bottom to open the
User Value Selection dialog.
a. Click on User Defined Units and type "kg/l" in the units field.
b. Type "Steam Rate" in the name field at the bottom.
c. Be sure the "Associate with a New Specifier" checkbox is selected if
desired.
d. Click the OK button to exit the dialog.
4. Rename the user value set to Steam Rate be more descriptive
5. Right click on the blue parameter field and select "Show Calculator" to open the
simple specifier dialog associated with the Steam Rate user value set.
a. Add independent variables for the steam mass flow rate and the amine
standard liquid volumetric flow rate. Double-check that the amine flow
rate and the steam flow rate are on the same basis (i.e. both are a rate
per minute), then click OK to exit the property moniker dialog.
b. Type in the equation "SteamFlow/AmineFlow" for the specified value,
assuming your variables are named SteamFlow and AmineFlow.
c. Close the simple specifier dialog.
6. Open the Steam Rate user value set dialog again, right-click on the blue
parameter field and select "Add to Short Moniker List" to open the moniker
builder dialog.
7. Type "Steam_Rate" as the short moniker and click the Add/Reset Short
Moniker button.
8. Drag a property table from the ProMax Streams stencil and place on the flow
sheet.
9. Double-click the property table to open the dialog, and in the lower left corner
of the dialog, click the Moniker radio button and leave the short moniker
check box selected. Available selections will include all short monikers for the
project. Select the Steam_Rate moniker by clicking on it, then click the arrow
button to transfer to the Displayed Selections. Click OK to exit the property
table dialog.
17
Exercise 10: Tail Gas Ratio User Value
A parameter often used in a Claus Sulfur Recovery unit is the Tail-gas H2S to SO2
molar ratio, which is typically controlled to be as close to 2 as possible. Create this
Tail-gas H2S to SO2 Ratio User Value for both Claus trains and display the
parameter in a Property Table for the flowsheet from Exercise 8: Prioritization of a
Large Multi-Flowsheet Plant.
18
Heat Exchanger Rating
Exercise 12: Crude Oil Shell & Tube Exchanger
The first objective is to define two hypothetical oil components and use the heat
exchanger rating utility within ProMax. Use the following information to create the
lube and crude oil components and define the feed streams. A drawn version of this
may be found in the training session files saved as Exercise 12 Crude Oil Shell &
Tube Exchanger.
Mixer
3 Splitter 2
6 7
19
20
Exercise 13: Rating a Multi-Sided Compact Heat Exchanger
A natural gas stream with the conditions and composition listed below is to be cooled to
-75C before being throttled to a lower pressure. Set up a complex exchanger which
uses the flashed vapor and liquid to cool the natural gas. Determine whether or not the
exchanger will perform based on the following ALPEMA datasheet. You must draw
this flowsheet.
5 Flash Vapor
7 Flash Liquids
XCHG-100
21
22
ProMax Calculator Methods
ProMax offers many options to help you arrive at your desired solution. These solvers
and specifiers range from very simple concepts to very complex and elaborate solution
methods. The primary options available are:
Simple solvers and specifiers
Using JScript in simple solvers to arrive at slightly more difficult specifications
Using JScript or VBScript in advanced solvers and advanced specifiers allowing
for much more complex equations and methods to solutions
Grouping simple solvers together.
Using the Excel calculator in advanced calculators
Simple Solvers created in ProMax utilize a simple JScript code. Typically these
calculators are set up as a single function to solve for a single specification.
However, there is additional functionality available in the simple solver than is typically
used. The following examples take advantage of both the simplicity of the simple
solver and the added functionality of this JScript coding.
If-Then-Else statements can be used; however these occasionally will not work as
expected due to the tolerances that ProMax allows in its solutions. A better approach is
the Math.max function available if attempting to have a solution that meets two
different specifications.
Please refer to our Help menu regarding the full functionality of JScript.
23
Exercise 14: DEPG Acid Gas Removal with JScript Simple
Solver
Simulate an AGR Contactor used to remove both CO2 and H2S from the feed stream.
Create a single simple solver, using JScript functionality, to find the necessary DEPG
flow rate to assure always meeting both 5% CO2 and 40ppmv H2S in the sweet gas.
Assume a saturated inlet gas with the following composition:
1 Lean DEPG
2 AGR Tower
Saturator
Water Saturant
Rich DEPG
24
Exercise 15: MDEA Sweetening with JScript Simple Solver
Simulate an MDEA sweetening tower to sweeten the water-saturated sour gas to 12
ppmv H2S. However, also ensure that the rich loading does not exceed 0.45 mol total
acid gas/mol amine.
Create a simple solver, using JScript functionality, to ensure that both specifications are
met, starting with the unsolved Exercise 15 Simple MDEA for Scripting Simple
Solver file in the training session files. This file is executed, but not at the optimized
conditions.
Conditions: Composition Mole %
Temperature 34 C H2S 0.5
Pressure 70 barg CO2 3
Flow 11000 Nm3/h C1 90
C2 5
C3 1
C4 0.5
Additional Process Information
The regenerator has a condenser temperature of 48C, and a reboiler steam rate
of 0.12 kg/l amine.
The rich flash operates at 5 barg, and the lean/rich exchanger heats the rich
amine entering the regenerator to 100C.
The amine is a 40 wt% solution
Questions
What flow rate is required to meet the specifications above?
What flow rate is required to meet these specifications if the MDEA mixture is
diluted over time to 36 wt%? Which constraint is controlling this flow rate?
25
Use of Advanced Calculators
advanced calculators are specifiers or solvers with multiple calculated and
measured variables
They offer extreme flexibility but are more complicated to create
Like their simple counterparts, calculations in advanced specifiers are
specification calculations and calculations in advanced solvers are objective
function calculations
Mathematically discontinuous functions are prone to convergence failure in the
solver
Two types of advanced calculators are availableScript- and Excel-based
Applications of advanced calculators
o Grouping functionality of multiple simple calculators into a single
calculators
o Consolidation of calculator codecan view all code at a single time
o More complicated mathematical expressionsnot limited to single line
expressions
o Can obtain additional ProMax data not available in simple calculators
(e.g., pure component properties)
o Used in solvers when there is a multivariable relationship rather than a
single variable relationship
Script type calculators allow both Jscript (used in simple calculators) and
VBScript by user selection
o Requires writing a subroutine in the selected language to specify
parameters or to evaluate solver objective functions
o Jscript is a case sensitive language while VBScript is case insensitive
o VBScript has similar syntax to VBA (Visual Basic for Applications)
used to write macros in Microsoft Office applications
o Complete documentation for both languages is available in the Help-
>ProMax Help->Scripting Reference menu item
Excel based advanced calculators
o Used when calculations are more naturally available in Excel
o Like exporting and importing, require an OLE embedded Excel
Workbook in the ProMax project
o Involves extra overhead relative to script calculators including OLE
Workbook and data transfer between two processes
o Should restrict use to cases where calculations need to be made in Excel
26
Creating an Advanced Calculator
1. Open the Project Viewer and right-click on calculator node in the navigation
tree.
2. Click on "Add..." in the pop-up menu to open the Calculator Specification
dialog.
3. Select Specifier or Solver from the Calculator Specification dialog.
4. Select Script or Excel from the Calculator Specification dialog.
5. Click OK to save your choices.
To open the Advanced Specifier dialog or the Advanced Solver dialog, locate
the Specifier or Solver in the Project Viewer navigation tree and double-click on
the item, or right click on the item and select "Show" from the pop-up menu.
After accessing the Advanced Calculator, select variables from the Advanced
Solver or Advanced Specifier dialogs by clicking on the "Add..." buttons.
Click on the "Code Source..." button to open the Scripting Development
Environment dialog.
Select JScript or VBScript as the scripting language by clicking on your
selection at the top of the dialog.
Write the Advanced Solver or Specifier script:
27
Advanced Specifiers
Complex Mixed Refrigerant Plant Example
The following three exercises will show how to use advanced specifiers to control
various properties of a project. In this example, calculators are used to set the
temperature out of selected sides of the complex exchangers and the pressure for the
first two stages of compression in a 3 stage compressor.
This file can be found in your training session files as Exercise 16, 17, 18 Complex
Heat Exchangers with Mixed Refrigerant. The unsolved version is executed, however
does not include any of the Advanced Specifiers covered in the next several pages.
28
Exercise 16: XCHG-100 Hot End Approach Advanced Specifier
Create an Advanced Specifier to set the temperature of Stream 54 to 4C below the feed
stream 1-Feed Gas, and Stream 11 and Stream 4 both 2C below the feed stream,
which has a known temperature. The use of an Advanced Specifier allows for a single
calculator instead of 3 different Simple Specifiers. Please refer to page 28 for the
flowsheet diagram.
To view the Advanced Specifier dialog, open the Project Viewer and click on
the Calculators node in the Navigation Tree to the left. Then double-click on
"XCHG-100 Hot End Approach Advanced Specifier".
This Specifier uses the following Variables:
Variables can be added using the Moniker Tree or from pre-defined Short
Moniker variables.
For this example, the temperatures of streams 54, 11 and 4 should all be added
as Calculated Variables.
Each of these Calculated Variables should then have an Associated Measured
Variable assigned as the temperature of the inlet stream (1-Feed Gas).
In the Advanced Specifier dialog, click the "Code Source..." button to view the
Scripting Development Environment dialog. This code sets the temperatures of
the three streams relative to the 1-Feed Gas temperature.
29
Exercise 17: XCHG-101 Advanced Specifier
Referring to the Complex Mixed Refrigerant Plant Example on page 28, create an
Advanced Specifier to
Referring to the Complex Mixed Refrigerant Plant Example on page 28, create an
Advanced Specifier to
Set the outlet pressures for the 1st and 2nd stages of compression such that
the compression ratios for each stage are approximately equal.
Use the equations
o 1st Stage Outlet Pressure = Inlet Pressure * (Discharge Pressure /
Inlet Pressure) ^ (1/3)
o 2nd Stage Outlet Pressure = Inlet Pressure * (Discharge Pressure /
Inlet Pressure) ^ (2/3)
Inlet Pressure = Stream 54
Discharge Pressure = Stream 46
1st Stage Outlet = Stream 42
2nd Stage Outlet = Stream 44
30
Advanced Solvers
Exercise 19: Sulfur Hydrogenation Reactor Advanced Solver
The Simple Sulfur Hydrogenation Reactor example illustrates how to model a
Hydrogenation or "TGCU" Reactor and the associated Reducing Gas Generator or
"RGG" Reactor. An unsolved version can be found in the training session files as
Exercise 19 Sulfur Hydrogenation Reactor.
Air Feed
Bone Dry Air
Fuel 5 3
MIX-101
MIX-100 Reducing Gas Burner
Simulation Discussion
The Bone Dry Air stream is saturated to 70% in block Saturator then mixed
with the Fuel gas before being fed to the Reducing Gas Burner. Use 100%
Methane as the Fuel gas in this example.
The Reducing Gas Burner effluent is mixed with the tail gas "From Claus Beds"
before being fed to the Hydrogenation Reactor.
The Hydrogenation Reactor converts all sulfur species to H2S before being fed
to the Tail Gas Cleanup Unit (TGCU). This is an adiabatic reactor Type "Gibbs
Minimization" with Gibbs Set Sulfur Hydrogenation.
Reducing gas is required to convert all sulfur species to H2S. This reducing gas
can be "pure" hydrogen or can be provided by a Reducing Gas Generator
(RGG). The RGG provides H2 and CO by burning fuel gas, and is modeled as an
adiabatic reactor Type "Gibbs Minimization" with Gibbs Set "Burner.
Excess H2 should be present in the Hydrogenation Reactor effluent (about 1%)
to assure that all sulfur species have been converted to H2S.
The Hydrogenation Reactor outlet temperature should be maintained at 260C -
370C by adjusting the amount of Fuel gas fed to the RGG.
The Advanced Solver "Hydrolyzing Bed Solver" simultaneously feeds enough
air to the RGG to achieve 1% H in the Hydrogenation Reactor effluent and
2
31
Following is the Advanced Solver dialog:
Click the "Code Source..." button to view the VBscript for the Solver.
32
Exercise 20: Crude Oil Exchanger Advanced Solver
Using the previously solved Exercise 12, define an advanced calculator that will
automatically determine the exchanger performance such that you have an excess of 5%
surface area at the converged conditions.
The exchanger percent over design will be your measured variable within the
solver.
You will have four calculated variables that represent the four lube oil outlet
temperatures from each exchanger.
The code source should be written to calculate the lube oil outlet temperature
from each exchanger that results in an exchanger with 5% over design.
33
Advanced Calculator Using Excel
Requires OLE embedding an Excel workbook in the ProMax projectability to
add an Excel calculator is disabled without the workbook
Pertinent worksheets in separate workbooks must be copied to a ProMax OLE
embedded workbook
Variables are selected in ProMax just like with script based calculators
Must map all variables to ranges in Excel for exporting and importing
Calculations are performed by the Excel engine
All data must be transferred across process boundary which can be relatively
slow
34
Exercise 21: Example Problem with Excel Calculator
Use an advanced calculator to adjust either the duty or temperature change across the
exchanger so that the UA ProMax calculates matches the UA calculations from an
existing Excel worksheet.
An unsolved version of both the ProMax and Excel files are available as Exercise 21
Double Pipe Exchanger using Advanced Solver in Excel. The Excel sheet performs
heat transfer calculations based on the Sieder-Tate equation. This equation estimates
the Nusselt number as:
0.14
1 b
N Nu = 0.023N 0. 8
N 3
w
Re Pr
Cp Dv hD
N Pr = ; N Re = ; N Nu =
k k
The Excel workbook will calculate the clean and service overall heat transfer
coefficients based on tube outside area and also calculate the UA product.
The purpose of the advanced solver in ProMax is to drive the UA product
calculated by ProMax equal to that calculated in the Excel workbook from the
heat transfer coefficient calculation.
All properties of the inlet and outlets that are required to evaluate the heat
transfer coefficients must be made measured variables and exported to Excel.
These include the temperatures, mass heat capacities, mass densities, viscosities,
and thermal conductivities.
Additionally the mass flow rates of each fluid must also be selected as measured
variables for export to Excel. The calculations in the Excel workbook require
the viscosities in kg/(ms).
A double pipe heat exchanger is available to heat 4455 kg/hr of cold benzene at 27C.
A stream of 2870 kg/hr of toluene at 70C is available for this purpose. The heat
exchanger has the following characteristics:
Property Value
Inside pipe ID 3.5 cm
Inside pipe OD 4.25 cm
Outside pipe ID 5.25 cm
Tube length 33.5 m
Tube thermal conductivity 59 W/(mC)
Benzene will be placed in the tube and toluene in the annulus. Use a fouling resistance
of 0.00018 Cm2/W on both sides.
If the above heat exchanger is selected for this service, what will be the discharge
temperatures for both the benzene and the toluene?
35
Advanced Column Configurations
Column Set-up
ProMax allows almost any column configuration to be created. Some of the primary
options available are:
Multiple Tower Types
o Columns can be configured as liquid-liquid, vapor-liquid or vapor-light
liquid-heavy liquid
o Equilibrium, TSweet Kinetics, TSweet Alternate Stripper, Polar Liquid
and Non-Polar Liquid tower types are available to accurately solve the
column
Connected Condensers and Reboilers
o For ProMax to recognize a condenser or reboiler as part of the column,
these must be associated in the Project Viewer, Process Data tab at
the bottom
o Associated condensers and reboilers do not require a recycle block for
the returning streams. These blocks, once associated, are actually
considered an additional stage to the tower. Thus any stream exiting the
tower and entering either the condenser or reboiler is treated as a pump-
around stream.
o These associated blocks will solve simultaneously with the column, and
any specifications for the additions can be made inside the main column.
Reboiler Options
o There are many variations of reboilers that can be simulated in ProMax.
These include both bottoms reboilers and side reboilers
o Thermosyphons, forced flow and kettle reboilers are available
o Side reboilers can include same stage returns, thermosyphon types,
forced flow types and even direct energy injection to the stage
Connected Side Strippers
o The specifications for these side columns can be made in the main
column
o All connected columns are executed simultaneously, and no recycles are
necessary for streams returning to the main column from an attachment.
Vapor and Liquid Draws
o By default, the draw off the tray is a light liquid
o Right-click on the tray in the Project Viewer, Connections tab to
change this default to either vapor, or heavy liquid (available only in a
VLLE tower).
Pump-around Loops
o Can include pumps and heat exchangers. Splitters can also be used, but
will require an additional pump-around estimate as a specification in the
tower.
o Specification can be made in the main tower, or in the heat exchangers
36
Column Execution and Convergence
While ProMax will allow almost any column configuration, occasionally these
configurations or the specifications set can be difficult to converge. Below are some
hints and steps to take to help these towers converge.
37
Column Fails to Converge
Check all Inlet Streams
First and foremost check each of your column feed streams. If these are not at
the expected conditions, then the column is more likely to fail.
Check Specifications
Confirm that the specifications do not imply an impossible separation.
Delete Specification Tolerances
If a tolerance is set, delete the value. In general, setting the specification
tolerance is discouraged, as the program will automatically choose an optimal
tolerance.
Try Easier Specifications
The ratio specifications automatically created by ProMax are natural variables
for the solver. These specifications will be easiest for ProMax to solve, and may
help obtain an initial column profile, allowing you to then enable a more
difficult specification (such as component compositions, TVP, or temperatures).
Confirm Vapor and Liquid on All Stages
Vapor and liquid must be present on each stage of the distillation column. If the
column does not have a condenser or reboiler, confirm that a feed containing
some liquid or vapor, respectively, exists on the top or bottom stage.
Change Enthalpy Model
This option is found in the column Convergence tab; choices are Boston-Britt or
Composition-Dependent. The default Boston-Britt should be used when there
are no convergence problems.
o Composition-Dependent is a unique enthalpy model and is useful for
unstable or difficult-to-converge columns (e.g. ionic columns, especially
amine strippers, or columns with extremely wide or narrow boiling point
differences between the components).
o The Composition-Dependent enthalpy model can be prohibitively slow
for a large number of components in a non-electrolytic environment. If
the column does not converge and oscillates within the first 50 iterations,
stop execution and check the validity of input data, especially
specifications.
Change Inner Loop Model
This option is also found in the column convergence tab; choices are Boston-
Sullivan or Boston-Sullivan Non-ideal. Boston-Sullivan is the default and
should be used when there are no convergence problems.
o Boston-Sullivan Non-ideal is useful for unstable or difficult-to-converge
columns (e.g. highly-loaded amine absorbers, absorbers where the amine
becomes the limiting reagent and strippers operating near minimum
reflux).
o The Non-ideal model should be used in combination with the
Composition-Dependent enthalpy model. This model can be
prohibitively slow for a large number of components in a non-
electrolytic environment.
38
Add Initial Estimates
Add initial estimates, especially for more "difficult" specifications such as
component flows or draw temperatures. Reflux ratio and boil-up ratio estimates
are often helpful, as are flow rate estimates for side draws.
Change Column Type
The polar liquid column type can aid convergence in columns which have a non-
polar vapor phase in contact with a polar liquid phase (e.g. methanol-protected
cold process).
Use K Damping
Try changing the K damping parameter in the column convergence tab.
o Although some damping is performed internally in the column
calculations, specifying a K damping parameter can be beneficial. The
value for the K damping should be non-negative integers up to about 10
(using too high of a value can lead to erroneous convergence).
o Increasing the K damping can be useful if the outer loop error oscillates
or when the error For staged column X the inner loop calculation failed
due to an invalid stage temperature calculation.
Enable/Disable Boston-Sullivan Kb
Try using Boston-Sullivan Kb found in the convergence tab; or, if Boston-
Sullivan Kb is enabled, clear the checkbox to disable. This parameter can aid
convergence for very wide or very narrow boiling mixtures.
Increase Maximum Iterations
If the column appears to be converging, but exceeds the maximum iterations,
this value can be increased in the solver grouping of the convergence tab.
Monitor Specifications and Variables
Monitor the specifications and variables in the tables on the specifications tab,
and compare the calculated value to the specified target value. For example, if
the reflux ratio is set to 1, the column fails, and the calculated value is 0.1, there
is likely not enough liquid flow at the top of the column.
Modify Variable Estimates and Bounds
The column provides an estimate for variables if an estimate is not provided by
the user. The Target values for these variables can be changed on either the
specifications tab or convergence tab, variables grouping. Lower and upper
bounds can also be specified.
Add a Recycle to the Pump-around Loop
If the column has a pump-around loop and fails to converge due to errors in the
pump-around blocks or the loop itself, or if the column calculations are
exceedingly slow, consider adding a recycle block to the pump-around loop.
When the recycle is added to the loop, the pump-around effectively becomes a
"draw". The draw rate is still specified in the column Specifications tab, but no
pump-around estimates are required for exchangers or pumps in the loop.
39
Exercise 22: Demonstration of Reboiler Options, Advanced
Column
ProMax offers many options to model various reboiler types. The flexibility of ProMax
allows for many different choices of both bottom reboilers, including Kettle and
Thermosyphon types, and side reboilers. These options will allow your simulation to
best match your operating conditions. Some of the possible configurations are
demonstrated below.
Boiling Shell Kettle: In this case, a selection has been made to calculate the
heat transfer details based on pool boiling for the shell
side of the default kettle reboiler options.
Thermosyphon with Recycle: A thermosyphon reboiler can be modeled with a
specified flow rate through the exchanger if a recycle
is included.
Thermosyphon without Recycle: No recycle is needed if the split to the reboiler is done
through a fractional basis.
Induced Flow: This models a full flow reboiler with partial liquid
return to the column.
40
Side Reboiler Options:
41
Exercise 23: Sour Water Stripper with Pump-around and
Thermosyphon Reboiler, Advanced Column
Simulate a sour water stripper used to clean the ammonia and hydrogen sulfide from the
feed stream. An unsolved version may be found in the training session files as
Exercise 23 Advanced Column Example - Sour Water Stripper. Assume the
following feed composition:
42
Exercise 24: Glycol Unit with Attached Stahl Column,
Advanced Column
Add an attached column to the regenerator of the following glycol unit to enhance the
stripping of water from the glycol. This file is saved in the training session files as
Exercise 24 Advanced Column Example Stahl Column; the exercise file is a
solved, working glycol unit, but with a less effective regenerator design than the
following.
Questions:
1. How does the new dry gas water content compare with the original case?
2. How does the lean glycol composition compare with the original case?
3. How do your BTEX emissions in the water gas compare with the original case?
43
Exercise 25: Stabilizer with Heavy Liquid Draw and Side
Reboiler, Advanced Column
Simulate the following stabilizer column based on the information provided. The
simulation can be found in the training session files saved as Exercise 25 Advanced
Column Example Stabilizer with Heavy Liquid Draw.
Feed Conditions: Composition (mol%):
Temperature: 50C Methane 3 Heptane 4
Pressure: 15 bar Ethane 7 Octane 4
Flow rate: 12,500 lpm Propane 20 Nonane 4
i-Butane 6 Decane 3
n-Butane 7 C11 3
i-Pentane 4 C12 3
n-Pentane 3 C13 2
Cyclohexane 5 C14 2
H2O 6 C15 10
Hexane 4
2 9
8
3
4 Stabilizer
6 7
3 8
XCHG-100 9
10 1
K-100
Q-1
2
5
44
Reactors
General Review of Chemical Reactions
In the above convention, the stoichiometric numbers vi are negative for reactants
and positive for products
For reversible reaction in the liquid phase
2A
R + S
45
For gas phase reactions with a rate expression in terms of partial pressures:
rA = k cf p A2 k cr p R p S
v i i =0
v G i i
o
+ RT ln a ivi = 0
or
vi Gio
= exp G
o
K = a = exp
vi
RT
i RT
The above equation relates the equilibrium constant K and activities of
components in the reacting mixture to the G io for each pure component and
defines the term G o known as the standard Gibbs free energy change of the
reaction. For a given standard state (which can be different for each component
in the system), the Gibbs free energy change and consequently the equilibrium
constant K are solely a function of temperature.
For gas phase reactions, the standard state is usually the ideal gas state at unit
pressure (1 atm, 1 bar, 1 psia, 1 Pa, etc.) so f i o = 1 (atm, bar, psia, Pa, etc.) and
the equilibrium constant is expressed:
K = fi vi
This requires the fugacities fi to be in the same pressure units as the unit
pressure basis. Further, the G io used to calculate the equilibrium constant must
also be at the same unit pressure. If the reacting system is assumed to be an
ideal gas,
K = p ivi
Liquid phase reactions usually use a different reference state so the general
relationship using activities must generally be employed
46
Reaction Sets
Provides a grouping of reactions that will be used in a non-Gibbs free energy
minimization reactor
Contains one or more consistent reactions
Reactors with simultaneous or consecutive reactions will use reaction sets with
more than one reaction
Reactions in a reaction set must be consistent with respect to type of reaction
and thermodynamics
Sets are created at the project level and are available for use in any environment
Reaction sets must be added to an environment
An individual reaction may be shared among multiple reaction sets
Reactions within a set may be made active or inactive
A reaction set is selected at the reactor level and may be customized in each
reactor
Reaction sets are created by right clicking the Reaction Sets node in the ProMax
Project Viewer and selecting the Add menu item
Equilibrium Reactions
Used with reactions that occur quickly or attain thermodynamic equilibrium
Unlike Gibbs Minimization reactions, equilibrium reactions are restricted to
stoichiometry defined by the reaction set
User supplied thermodynamic equilibrium expression of the form:
B
ln K = A + + C ln T + DT + ET 2
T
Alternatively, equilibrium constant can be calculated internally from reaction
standard Gibbs free energy change:
G o
K = a ivi = exp
RT
47
where vi are the stoichiometric numbers of each respective species. The
standard Gibbs free energy change for a reaction is calculated by:
G o = v i Gio
Conversion Reactions
Allows modeling where the conversion of a base component is stated as a user
supplied quadratic function of temperature
Base component must be selected
The Priority is used with multiple conversion reactions in a setestablishes
rank of reaction calculation
Kinetic Reactions
Require user specification of reaction rate constant equations through Arrhenius
type expressions:
E
k = koT n exp a
RT
For bidirectional reactions, rates in both forward and reverse directions can be
specified or only a single direction can be specified with the other direction
calculated from equilibrium requirement:
kf
K=
kr
Overall reaction rate is determined from the reaction orders of the individual
components, the forward and reverse reaction rates, and the adsorption term
using one of the following equations:
N N
k f C j f , j kr C j r , j
j =1 j =1
r=
AR
N 1 N
k f C j f , j C j r , j
K j =1
=
j =1
AR
N N
kr K C j f , j C j r , j
=
j =1 j =1
AR
where C j is the concentration of the jth component in the user selected basis,
f , j and r , j are the order for the jth component in the forward and reverse
48
directions, respectively, and AR is the adsorption resistance which models the
diffusion in and out of the pores of the catalyst. The k f and k r are calculated
from the Arrhenius expression provided by the user. The adsorption resistance
given by the general expression:
n
N
AR = 1 + K m C j m , j
m j =1
where m, j is the order for the jth component in the mth adsorption term, and K m
is the adsorption constant given also by an Arrhenius expression:
E
K m = ko exp a
RT
The adsorption resistance is normally unity for non-heterogeneous catalysis
reactions.
Flexibility in concentration units for rate expressions and reaction orders
Reactions occurring on a heterogeneous catalytic surface are usually based on
mass of catalyst and require specification of catalyst particle density. Particle
density and bulk density of the catalyst are related by:
b
p =
1
with representing the void fraction of the catalyst bed
As with equilibrium reactions, the equilibrium constant expression can be
obtained from user specification as a function of temperature or from its
thermodynamic definition using the standard Gibbs free energy change of the
reaction
Additional Information:
49
Reactor Blocks in ProMax
Types of reactors available in ProMax
o Gibbs minimization
o Equilibrium
o Conversion
o Stirred Tank
o Plug flow
All allow adiabatic and non-adiabatic calculation
Tight integration into heat exchanger rating package
Reaction usually occurs in a single phase but multi-phase reactions can be
modeled
All except Gibbs minimization require a single reaction set to be selected
Reaction set must be placed in environment before available in reactor
Use single sided reactor for adiabatic or duty specified units
Use cross reactor when both a reactor and heat exchanger calculation is required
to model coolant or heating mediumperformance of coolant or heating
medium in exchanger can be modeled by specification of overall heat transfer
coefficient
Use program help to obtain more information and see examples distributed with
program
50
Gibbs Minimization Reactors
Solves for thermodynamic equilibrium by minimizing the Gibbs free energy of
the system
Adiabatic, duty specified, or temperature specified calculation
Usually does not utilize reaction setssimply place a reactor on the PFD and
select the type to be Gibbs Minimization
Only considers consumption and production of components selected by the user
Environment must contain all desired reactants and productsthose missing
will not be considered
Several Gibbs sets are available in ProMax which preselect the reactants and
products as well as constraints
The General Gibbs set allows all components in the environment to reactlist
usually must be limited to desired reactants and products
Allows for constraints to be applied to the minimization calculation
Number of constrains is limited by the number of reactants and products
Several predefined constraints are available in ProMax which are used in burner
and sulfur plant modeling
Linear constraints are most general and allow the amount of a specified
component in the effluent to be a linear function of the inlet
51
Exercise 27: Incinerator/Fired-Boiler, Gibbs Minimization Reactor
In this example, fuel gas and air are mixed, preheated, and fed to a burner to generate
9,000 kg/hr of 4.4 bar saturated steam. This file can be found in the training session
files as Exercise 27 Combustor in Gibbs Minimization Reactor.
Air Q-1
REAC-100
BFW 50 # Steam
2 4 XCHG-100
MIX-101 XCHG-101
5
Fuel
Questions:
1. What is the Fuel Gas rate in Nm3/h required to generate the required amount of
steam?
2. How many moles/hr of oxygen are required to combust the fuel gas?
3. What is the temperature of exhaust gas leaving the preheater?
4. Basing off of the Gross Ideal Gas Heating Value, what is the steam cost per day
to generate this steam? Assume energy costs are 3 pence/kWh or 5 Euro cents /
kWh.
52
Equilibrium Reactor Blocks in ProMax
Uses reaction sets with equilibrium reactions enabled and optionally specified
temperature dependent equilibrium constants
Equilibrium constants calculated from Gibbs free energy change if not specified
Adiabatic, duty specified, or temperature specified modeling
Use single sided type reactor for adiabatic or duty specified units
Use cross reactor when both a reactor and heat exchanger calculation is required
to model coolant or heating medium
Can provide same results as Gibbs minimization reactor depending on how
reaction set is specified
53
Exercise 28: Steam Methane Reforming (SMR), Equilibrium Reactor
SMR is the predominant procedure for producing hydrogen. In this exercise we will
finish defining the reaction set for this important reaction, and then model a pair of
equilibrium reactors based on this reaction set.
Expanding on Exercise 26 from page 49, create a reaction set in ProMax that can be
used to model the following steam-methane reforming reactions.
For Reaction 1: Use methane as the conversion base, and use Keq from Gibbs.
For Reaction 2: Use carbon monoxide as the conversion base, and use Keq from
Gibbs
Assume a 0C approach for both reactors.
Model an equilibrium reactor in which the reactions occurs as the reaction set was
defined above, and an identical unit in which the approach for the steam-methane
reaction has a 25 C approach temperature.
The outlet of the reactor has a temperature of 800 C and pressure of 12.3 bar.
Q-1
Approach
SPLT-100 Q-2
4 No Approach
54
Exercise 29: COS Hydrolysis in an Equilibrium Reactor
Carbonyl sulfide (COS) is a naturally occurring component of natural gas and liquefied
petroleum gas (LPG). COS will hydrolyze (react with water) to form carbon dioxide
and hydrogen sulfide according to the reaction
Kohl and Riesenseld in their book Gas Purification report Terres and
Wesemann have measured the following equilibrium constants at 20 C:
ln K1 = 13.49
ln K2 = 22.69
The COS hydrolysis reaction is kinetically limited and does not go to complete
equilibrium. A mole fraction of 0.01% COS is measured in the product. Use the
bypass option in the equilibrium reactor to match the measured composition.
55
Conversion Reactor Blocks in ProMax
56
Exercise 30: HF Alkylation using a Conversion Reactor
In HF alkylation C3, C4 and C5 olefins are combined in the presence of the acid
catalyst to produce alkylate gasoline. Gerald Kaes in his book Refinery Process
Modeling lists the following alkylate composition produced by reacting one mole of
butene-1 with one mole of isobutane:
Part I
Assuming a 6:1 isobutane to olefin ratio calculate the product composition using a
conversion reactor. The feed conditions are 38C, 12 bar and a rate of 1000 lpm. The
reactor is operated isothermally using 450,000 kg/hr of cooling water at 21C. What is
the cooling water duty?
Part II
Using a cross reactor, determine the overall heat transfer coefficient that is required to
maintain isothermal operation using the following parameters:
Assume the water conditions are unchanged from Part I. Does enough heat transfer
area exist in this unit assuming a 1.7x10-4 Cm2/W fouling resistance on both sides?
57
Exercise 31: Defining a Catalytic Reaction Set
The heterogeneous catalytic synthesis of methanol was studied by Cappelli et al. (Ind.
Eng. Chem. Process Des. Develop., Vol. 11, No. 2, 1972) in a FauserMontecatini
reactor over ZnO and Cr2O3 based catalysts. The synthesis reaction is:
CO + 2H2 <==> CH3OH
In addition to the methanol synthesis reaction, an additional reaction occurs that cannot
be neglected due to the fact that significant CO2 levels may be present in the feed:
CO2 + H2 <==> CO + H2O
At the temperatures of the reactor, the second reaction can be assumed to reach
equilibrium and its equilibrium constant can be assumed to be of the form:
fCO fH 2O
K=
f f
CO 2 H2
where the f i are the fugacities of the indicated species in atm. The rate of methanol
synthesis in kmol/hr-kg catalyst for the first reaction is given by:
fCO fH22 fCH 3OH / K eq
rCH 3OH =
A 3 (1 + BfCO + CfH 2 + DfCH 3OH + EfCO 2 ) 3
58
Plug Flow Reactor Blocks in ProMax
59
Exercise 32: Water Shift Reactors, Plug Flow Reactor
This system is used to convert carbon monoxide from the gas of an ammonia plant and
water to hydrogen and carbon dioxide. Inlet stream conditions are:
The process stream is cooled to 213C before entering the Copper-Zinc Oxide
Catalyst Reactor
The iron oxide reactor is a 36 BWG single tube 5.9 m long with a 3.8 m outer
diameter. Calculate the void fraction.
The Copper-Zinc Oxide reactor is a 12 BWG single tube 4.27 m long with a 3.8
m outer diameter. Calculate the void fraction.
Q-1
Inlet 1st Reactor Outlet 1st Reactor Inlet 2nd Reactor Outlet 2nd Reactor
Iron Oxide Catalyst Reactor XCHG-100 Copper-Zinc Oxide Catalyst Reactor
60
Stirred Tank Reactor Blocks in ProMax
Outlet is the same as all points internal to reactorreacting system is perfectly
mixed
Requires a reaction set containing at least one kinetic reaction
Additional equilibrium reactions possible in reaction set
Calculations require solving material and energy balances simultaneously with
reaction rates and equilibrium relationships defined in the reaction set
Adiabatic, duty specified, or temperature specified modeling
Use single sided reactor for adiabatic or duty specified units
Use cross reactor when both a reactor and heat exchanger calculation is required
to model coolant or heating medium
Key variable is usually reactor volume which is established through the reactor
length and diameternon-cylindrical forms must be specified as if cylindrical
61
Exercise 33: Allyl Chloride Production in CSTR and PFR Reactors
A pilot plant reactor is planned to study the production of allyl chloride (CASN 107-05-1)
from propylene and chlorine according to the reaction
63,267
r1 = 0.9166 exp pC3 H 6 pCl 2 , with T in K
RT
15,956
r2 = 15.21x10 5 exp pC3 H 6 pCl 2 , with T in K
RT
The reactor will be a 6100 mm long vertical tube of 55.54 mm ID. Calculate the
composition and exit temperature from the adiabatic PFR reactor.
Compare the results to those for a CSTR reactor of equal volume (11979 cm3).
Instead of adiabatic, both the PFR and CSTR will be jacketed with boiling
ethylene glycol which will hold the wall temperature constant at 200C. The
inside heat-transfer coefficient may be taken as 28.4 W/(m2C). Compare the
results to an adiabatic PFR and CSTR of the same dimension.
62
63