MODELS & CAPACITY

The bypass gas measurement loops are available in different standard sizes, any of which is added to a standard
MPFM-300 Series unit to complete a MPFM-400 Series unit. The size of the MPFM-300 used in the 400 model Process Measurement & Control
is based on the required liquid measurement capacity.

The following chart outlines which MPFM-400 Series meter would be used to handle flow rates for varying flow MPFM 400 Series
line sizes and gas to liquid ratios.
Multiphase Flow Meter (Oil/Water/Gas)

A g a r s M P F M S e r i e s
400 extends the dynamic
range and gas handling
capabilities of the
Multiphase Flow Meter.

ACCURACY
Accuracies are not affected by changes in salinity, viscosity, density, temperature, pressure or pH. Since the
MPFM-400 Series uses the MPFM-300 Series for core multiphase measurements, its accuracy is dictated by the
accuracy of the MPFM-300 as shown in the following table:

Oil Flow Rate 2% of full scale, plus 5% of reading

Water Flow Rate 2% of full scale , plus 5% of reading FEATURES: APPLICATIONS:

Gas Flow Rate 5% of full scale*, plus 5% of reading The ability to be used in all flow patterns High void fractions
Requires little maintenance High gas to liquid ratio
*Full scale depends on the size of the MPFM-400 Series bypass loop. Compact, portable, and easy to transport and Surging flow conditions
install
USA CAYMAN ISLANDS VENEZUELA MALAYSIA ABU DHABI INDONESIA Not affected by changes in fluid properties
Agar Corporation Agar Corporation Ltd. Agarcorp de Venezuela C.A. AgarCorp SDN. BHD. Agar Corporation (ACAD) PT AgarCorp Indonesia
5150 Tacoma Drive P.O. Box 10206 77 Edif. 5 de Julio, Piso 4, Ofiicina 168-1st Fl Main Rd Salak So 1505, Three Sails Tower Jalan Teratai CB-17 Measures in both oil- and water-continuous
Houston, TX 77041 Grand Cayman, BWI D-4, Sector Tierron Negra, Zona 57100 Kuala Lumpur Corniche, Khalidiya Ciputat Baru, Ciputat phases
Tel: (832) 476-5100 KY1-1002 Postal 4002, Maracaibo, Edo. Zulia Tel: 603-7980-7069 Abu Dhabi, UAE Tangerang 15413
Fax: (832) 476-5299 Tel: (345) 945-5242 Tel: +58 261 324 5789 Fax: 603-7980-5369 Tel/Fax: 971-2681-1779 Tel: 62 21 7409206 Gas void fraction 0-97%
ACI@agarcorp.com ACL@agarcorp.com ADV@agarcorp.com ACSB@agarcorp.com ACAD@agarcorp.com PTAI@agarcorp.com

www.agarcorp.com
www.agarcorp.com All Agar Corporation Instruments are covered by one or more of the following U.S. Patents: 4,503,383; 4,774,680; 5,099,697; 5,101,163; 5,101,367;
5,263,363; 5,503,004; 5,551,305; 5,589,642; 5,741,977, RE 36,597. Other patents pending in the USA and other countries.
ER No. 4967: SL0003 Rev -
MPFM 400 Series Description MPFM 400 General Specifications

PROCESS CONDITIONS
The AGAR MPFM-400 Series Meters (patents pending) are Instantaneous Void Fraction 0 to 99.6%
designed to handle a wide range of flow rates and gas-to-liquid
Watercut 0 to 100%
ratios in all flow patterns.
Flow Patterns All: (e.g. Bubbly, Wavy, Slug, Annular flows, etc.)
The meters are designed to extend the dynamic range of the Pressure Up to ANSI 1500#. Contact factory for higher ratings
gas and required rates of the patented AGAR MPFM-300 Series Ambient Temperature -4F to 158F (-20C to 70C)
multiphase flow meters (see MPFM-300 Series specification) by Optional Low Temp -40F to 158F (-40C to 70C)
adding a Fluidic Flow Diverter (FFD) Device and gas bypass Process Temperature Standard Model 32F to 212F (0C to 100C)
loop. High Temperature Model 32F to 450F (0C to 232C)
Viscosity .5 to 5000 Centipoise (Calibrated in two ranges: 1 - 100Cp and 100 - 5000 cP)
The FFD Device uses the difference in flow momentum of the Salinity Up to 0 to 20% by weight (up to saturation)
gas and the liquid to divert most of the free gas in the stream into
Sand/Particulate Up to 5% by volume and less than 1mm partical size
a secondary measurement loop around the core MPFM-300.
The remaining fluids flow through the core MPFM-300 Series Max. Pressure Drop Less than 15 PSI (1 bar)
system. The gas in the bypass loop is metered and added to the Wetted Parts Stainless Steel; Teflon; Ceramic; Elastomer; PEEK
oil, water and gas discharged from the MPFM-300 core unit. Contact factory for low flow options, extended range specifications

By reducing the amount of gas flowing through the MPFM300 TYPICAL DIMENSIONS: (ANSI 300*)
Series core unit, the MPFM-400 Series often allows the use
Weight Dimensions (F/FXWXH)
of smaller MPFM-300 units. This arrangement can reduce Model
the cost of measuring flow streams where gas is the dominant (Lbs.) (Kg.) Inches Centimeters
component of the flow. 401-20-20 1900 863 120x35.5x110 304x90x279
401-30-30 2600 1182 120x35.5x125 304x90x317
The extended dynamic range of gas measurement in the
MPFM-400 Series meters makes them 401-40-40 3800 1727 126x52x135 320x132x343
suitable for multiphase well testing in 401-60-60 5000 2270 126x62x200 320x157x508
wells with very high GOR or wells with *Weights and dimensions will vary for different gas loop options.
moderate GOR that are tested at low
pressure. Electrical:
Power Supply: 110, 220 VAC, 24 VDC (optional)
In addition, the FFD,assisted by a Power Requirements: 36 Watts with pneumatic actuator
valve, can be used as a batch separator.
This allows the measurement of very Safety Certifications:
ATEX- EEx ia IIC T6
low liquid flow rates, and increases the UL/C-UL - Class 1, Division 1, Group C & D, T4
liquid turn down ratio to approximately The MPFM is designed to meet NACE MR-0175 requirements.
100.
Data Communication (Standard and Optional):
Standard: LCD Screen
Standard: Text (Screen, FIle, Printer) indicating temperature, pressure, volumetric flow rate of
MPFM-400 Installation on an gas, oil, water, and total flow.
Offshore Platform. Application Standard: Graphics (Screen) indicating time trending and bar graphs of gas, oil and water flow
- Well Testing in a Gas-Lift rates, temperature, and pressure.
Operation; 99% GVF Standard: One RS232 and one RS485 outputs, MODBUS and ASCII protocol. Other types optional.
Standard: Hard Disk, Floppy Drive.
Standard: Analog Output Card to handle up to 6 outputs: 4-20 mA / 1-5V / Relay / Pulse Outputs / 0-5 VDC / 0-10
VDC or a combination of the above
Standard: MPFMWin software to be installed on the designated PC
Optional: Analog Input Card