Abstract
This study deals with the reduction of the stiffness in precast concrete structural elements of multi-storey buildings to analyze global stability.
Having reviewed the technical literature, this paper present indications of stiffness reduction in different codes, standards, and recommendations
and compare these to the values found in the present study. The structural model analyzed in this study was constructed with finite elements using
ANSYS software. Physical Non-Linearity (PNL) was considered in relation to the diagrams M x N x 1/r, and Geometric Non-Linearity (GNL) was
calculated following the Newton-Raphson method. Using a typical precast concrete structure with multiple floors and a semi-rigid beam-to-column
connection, expressions for a stiffness reduction coefficient are presented. The main conclusions of the study are as follows: the reduction coef-
ficients obtained from the diagram M x N x 1/r differ from standards that use a simplified consideration of PNL; the stiffness reduction coefficient
for columns in the arrangements analyzed were approximately 0.5 to 0.6; and the variation of values found for stiffness reduction coefficient in
concrete beams, which were subjected to the effects of creep with linear coefficients from 0 to 3, ranged from 0.45 to 0.2 for positive bending mo-
ments and 0.3 to 0.2 for negative bending moments.
Resumo
No presente trabalho investiga-se a reduo da rigidez de elementos estruturais de concreto pr-moldado de edifcios de mltiplos pavimentos
para a anlise da estabilidade global. Apresentam-se as indicaes da reduo de rigidez de diferentes cdigos, normas e recomendaes de
associaes encontradas na literatura tcnica, para servir de comparao com os valores encontrados no estudo. O modelo estrutural analisa-
do foi construdo em elementos finitos com o auxlio do software ANSYS. A no-linearidade fsica (NLF) foi considerada com as relaes dos
diagramas M x N x 1/r e a no-linearidade geomtrica (NLG) segundo o mtodo de Newton-Raphson. Tomando como base uma estrutura tpica
de concreto pr-moldado de mltiplos pavimentos com ligao viga x pilar de comportamento semi-rgido, so apresentadas expresses para o
coeficiente redutor de rigidez. As principais concluses do estudo desenvolvido so: os coeficientes redutores obtidos segundo o diagrama M x
N x 1/r divergem das indicaes normativas para considerao simplificada da NLF; o coeficiente redutor de rigidez para os pilares dos arranjos
analisados foi da ordem de 0,5 a 0,6; a variao dos valores encontrados para os coeficientes redutores de rigidez nas vigas em concreto armado
submetidos aos efeitos da fluncia pelo coeficiente linear de 0 a 3 foi de 0,45 a 0,2 para momento positivo e de 0,3 a 0,2 para momento negativo.
a
Department of Structural Engineering, So Carlos School of Engineering, University of So Paulo, cuadradomarin@yahoo.com.br, CEP 13566-590,
So Carlos, Brazil;
b
Department of Structural Engineering, So Carlos School of Engineering, University of So Paulo, mkdebs@sc.usp.br, CEP 13566-590,
So Carlos, Brazil.
Received: 23 Oct 2011 Accepted: 08 Mar 2012 Available Online: 26 Jun 2012
2012 IBRACON
Contribution to assessing the stiffness reduction of structural elements in the global stability analysis of
precast concrete multi-storey buildings
Onde:
0.2Ec I g + Es I s fcd resistncia compresso de projeto do concreto (MPa);
EI sec = (7) ndice de esbeltez;
1 + bd coeficiente de fluncia;
As ,tot rea de ao longitudinal total da seo.
Em que:
lm = qh 3.0 (17)
P0
h = 2 .5 + 1 .6 6 h 70 (18)
P anlise estrutural em elementos finitos. A considerao no simplifi-
cada da NLF implica em conhecer o diagrama M x N x 1/r, ou seja,
a rigidez, para cada seo em que houver mudana de esforo so-
licitante, seo transversal, armadura, cobrimento e fck. Isto significa
que quanto maior for a discretizao da estrutura em elementos
27
=
kL/r
- 0.05 (19) finitos maior a representatividade da soluo. O software ANSYS
[9] permite que a relao constitutiva de vigas e pilares seja repre-
sentada pelo diagrama M x N x 1/r no elemento finito BEAM188.
A discretizao adotada para modelagem da estrutura via mtodo
Onde: dos elementos finitos para os pilares foi de 8 elementos finitos por
P representa a carga axial no pilar em uma anlise de primeira trecho de pilar, onde cada trecho corresponde a regio entre pavi-
ordem; mentos. Nas vigas foram adotados 16 elementos finitos por trecho
P
representa a carga mxima centrada admissvel no pilar; de viga, onde cada trecho fica definido pela regio entre consolos.
0
representa o coeficiente de comprimento efetivo no pilar consi- Os consolos foram discretizados em um elemento finito, a rigidez
derando as condies de contorno; dos consolos foi definida pelo produto EciIc. Os elementos de liga-
L representa o comprimento no pilar; o foram modelados com o auxlio do elemento COMBIN39, este
r representa o raio de girao da seo. elemento permite que a relao momento x rotao seja represen-
Pode se notar neste caso que a expresso leva em conta as ca- tada de forma no-linear e assimtrica.
ractersticas geomtricas e de vinculao do elemento estrutural. A NLG foi analisada segundo o mtodo de Newton-Raphson com-
A Tabela 1 apresenta um quadro comparativo dos fatores conside- pleto, o critrio de parada do processo iterativo foi o de controle
rados nas recomendaes apresentadas, onde pode se constatar dos deslocamentos. A tolerncia definida foi de 0,5%, ou seja, o
que: a) existe uma grande diferena entre os fatores levados em processo iterativo era interrompido quando no houvesse acrs-
conta; b) a NBR 6118:2003 [1] a nica que tem valores fixos. Os cimo de mais de 0,5% de deslocamentos em relao iterao
fatores considerados se aplicam apenas a pilares. anterior. A anlise no-linear foi feita dividindo-se o carregamento
em 10 passos de carga.
3. Modelos de anlise Segundo a NBR 6118:2003 [1], a no-linearidade pode, em geral,
ser considerada atravs das relaes momento fletor x fora nor-
A estrutura em concreto pr-moldado considerada neste estudo foi mal x curvatura (diagramas M x N x 1/r ) para cada seo, com
modelada como prtico plano, utilizando o software ANSYS [9] de armadura supostamente conhecida e fora normal atuante. A NBR
FORA
VALOR NORMAL FLUNCIA ARMADURA ESBELTEZ
Ao do vento - Direo Y
Mdulo 7,5m 6 PAV 5 PAV 4 PAV
h(m) S2 Vk (m/s) q (kN/m2) H/L1 Ca Fa (kN) H/L1 Ca Fa (kN) H/L1 Ca Fa (kN)
4 0,76 34,20 0,717 0,80 1,24 28,11 0,67 1,21 27,43 0,53 1,18 26,75
8 0,80 36,00 0,794 0,80 1,24 31,46 0,67 1,21 30,70 0,53 1,18 29,94
12 0,85 38,25 0,897 0,80 1,24 34,97 0,67 1,21 34,12 0,53 1,18 33,28
16 0,89 40,05 0,983 0,80 1,24 37,41 0,67 1,21 36,50 0,53 1,18 17,40
20 0,91 40,95 1,028 0,80 1,24 39,09 0,67 1,21 18,66
24 0,93 41,85 1,074 0,80 1,24 19,97
h.: cota do pavimento; H: altura da estrutura; Vk:Velocidade caracterstica; S2: Fator que compe Vk; q: presso dinmica;
L1: maior dimenso da edificao em planta; Ca: Coeficiente de arrasto; Fa: Fora de arrasto.
Tabela 7 Coeficientes redutores de rigidez para pilar segundo as diversas prescries normativas
n M x N x 1/r NBR
l NBR 6118:2003 ACI 318-08 FIB PCI
9062:1985
0,58 27,71 0,625 0,800 0,471 0,429 0,758 0,162
0,58 63,74 0,625 0,800 0,471 0,498 0,758 0,038
0,03 27,71 0,333 0,500 0,471 0,280 0,758 0,015
0,03 63,74 0,333 0,500 0,471 0,283 0,758 0,038
n: Fora normal adimensional; l: ndice de esbeltez.
pr-moldado
adimensional nula igual a 0,319.
Para o pilar com seo de 40 x 40 cm foi constatada uma reduo
4.5
5 16mm
na rigidez a partir do valor da fora normal adimensional de 0,9. Nas
outras sees de pilares este comportamento no foi observado, pois
5 20mm o nvel de esforo normal era menor. A Figura 10 ilustra o diagrama
4.5
5
Mneg (a) 0,211 0,150 0,116 0,095
15
pr-moldado pavimentos com fck=35 MPa em seo composta por capa molda-
da in loco com fck=20 MPa. A armadura passiva constituda de
ao CA-50.
4 cabos
5
Medidas em cm
30 do coeficiente linear de fluncia igual a 0 e 2. Em virtude da dife-
rena de resistncia do concreto da seo da viga de concreto
pr-moldado e da capa moldada in loco, para efeito de construo
Na Tabela 9 so apresentadas propostas de funes de reduo do diagrama M x N x 1/r, o trecho referente ao momento positivo
de rigidez segundo os respectivos subdomnios para os pilares foi construdo com fck=20 MPa e o trecho referente ao momento
com seo de 40 x 40 cm, 50 x 50 cm e 60 x 60 cm. Alm disto, negativo foi construdo com fck=35 MPa.
proposta uma funo de reduo de rigidez mdia para cada A Tabela 11 mostra o coeficiente redutor de rigidez versus o co-
trecho estudado. eficiente de fluncia para o momento positivo e para o momento
Os exemplos numricos foram concebidos com diferentes sees negativo. Nota-se a diminuio significativa do coeficiente redutor
de pilares, de acordo com o nmero de pavimentos e a modulao de rigidez frente evoluo da fluncia.
utilizada. Na Tabela 10 podem ser observados os intervalos de co- O coeficiente redutor indicado pela NBR 6118:2003 [1] para vigas
eficientes redutores de rigidez obtidos para os pilares nos modelos com armadura assimtrica de 0,4. Valor semelhante ao encon-
analisados. Os valores mais baixos correspondem aos pavimen- trado para a rigidez secante ao momento positivo com coeficiente
tos superiores e os valores mais altos aos pavimentos inferiores. linear de fluncia igual a 0.
Considerando-se os valores mdios, o coeficiente redutor corres- Foi avaliado o efeito da adoo de armadura ativa na seo trans-
ponde a faixa de 0,5 a 0,6. Estes coeficientes so menores que versal da viga em concreto pr-moldado em seo composta, con-
os valores recomendados pela NBR 6118:2003 [1], de 0,7 e 0,8. forme ilustrada a Figura 13. O concreto pr-moldado da viga apre-
senta fck = 40 MPa, o concreto da capa moldada in loco apresenta
fck = 20 MPa. A armadura ativa presente na seo constituda de
cordoalhas CP 190 RB 12,7, a armadura passiva especificada
Figura 14 Diagrama M x N x 1/r em ao CA-50.
A Figura 14 mostra o diagrama M x N x 1/r modificado pela adoo
sob efeito da protenso com 9 cabos
de armadura ativa e a Tabela 12 apresenta os coeficientes reduto-
res de rigidez obtidos utilizando armadura ativa na face inferior e
armadura passiva na face superior da viga.
nos abrangentes que as formulaes apresentadas em nor- Proc. of 2nd Workshop Semi-rigid Behaviour of Civil
mas internacionais. Engineering Structural Connections, Prague, p. 21-30.
b) Os coeficientes redutores obtidos segundo o diagrama M x N [04] ELLIOTT, K. S.; DAVIES, G.; MAHDI, A.; GORGUN,
x 1/r divergem das indicaes normativas para considerao H.; VIRDI, K. & RAGUPATHY P. (1998). Precast
simplificada de NLF, principalmente sob efeito da fluncia, for- concrete semi-rigid beam-to-column connections in
a normal e armadura ativa. Os coeficientes redutores sofrem skeletal frames. COST C1 Proc. of The International
influncia do nvel de esforo normal, conseqentemente va- Conference, Control of Semi-rigid Behaviour of Civil
riam de acordo com a combinao de aes utilizada. Engineering Structural Connections, Lige, p. 45-54.
c) A taxa de crescimento da rigidez sofre uma variao quando o [05] KERONEN A. & HIETALA J. (1998). Tests and
valor da fora normal se aproxima de 0,25. analysis of the connections in precast concrete
d) Segundo os estudos realizados, o aumento do nvel de esforo portal frame. COST C1 Proc. of The International
normal incrementa a rigidez das sees, no entanto, a partir de Conference, Control of Semi-rigid Behaviour of Civil
um certo nvel de esforo normal existe uma diminuio da rigi- Engineering Structural Connections, Lige, p. 25-34.
dez da seo. No exemplo numrico avaliado, obteve-se o valor [06] CHEFDEBIEN, A. de (1998). Precast concrete beam
de fora normal adimensional de aproximadamente 0,9, onde to column head connections. COST C1 Proc. of The
ocorreu uma inverso da tendncia de incremento da rigidez. International Conference, Control of Semi-rigid
J as seguintes concluses so limitadas aos arranjos estruturais, Behaviour of Civil Engineering Structural Connections,
aes e, principalmente, ao tipo de ligao utilizada que viabilizou Lige, p. 35-43.
o sistema estrutural estudado e servem de base de comparao [07] ELLIOTT, K.S.; DAVIES, G.; FERREIRA, M..
com os coeficientes de rigidez da NBR 6118:2003 [1]: GORGUM, H.; MAHADI, A.A. (2003a). Can precast
Os coeficientes redutores de rigidez obtidos para os pilares dos concrete structures be designed as semi-rigid frames?
arranjos analisados apresentaram valores em mdia de 0,5 a 0,6. Part 1: The experimental evidence. The structural
A variao dos valores encontrados para os coeficientes redutores engineer. v.81, n.16 p. 14-27.
de rigidez nas vigas em concreto armado submetidos aos efei- [08] ELLIOTT, K.S.; DAVIES, G.; FERREIRA, M..
tos da fluncia pelo coeficiente linear de 0 a 3 foi de 0,45 a 0,2 GORGUM, H.; MAHADI, A.A. (2003b). Can precast
para momento positivo e de 0,3 a 0,2 para momento negativo. Nos concrete structures be designed as semi-rigid frames?
elementos com armadura ativa os coeficientes redutores obtidos Part 2: Analytical equations & column effective length
pertencem ao intervalo de 0,55 a 0,25 no combate ao momento factores. The structural engineer. v.81, n.16 p. 28-37
positivo e ao momento negativo os valores encontrados perten- [09] ANSYS RELEASE 10.0 (2005). Documentation for
cem ao intervalo de 0,25 a 0,1. Ansys. 1st ed. Chicago, USA.
Vale a pena destacar que o estudo realizado teve o objetivo de [10] AMERICAN CONCRETE INSTITUTE (2008).
avaliar a reduo de rigidez para um estudo de caso tpico de ACI 318-08: Building Code Requirements for
estrutura de concreto pr-moldado de mltiplos pavimentos, com Structural Concrete and Commentary. Farmington Hills.
um tipo particular de ligao semi-rgida. Assim, as concluses [11] FDRATION INTERNACIONALE DU BETON
so limitadas e servem para mostrar a diferena em relao aos (2002). Design examples for FIP recommendations
valores da NBR 6118:2003 [1]. practical design of structural concrete, Bulletin FIB,
Lausanne, v.16.
6. Agradecimentos [12] ASSOCIAO BRASILEIRA DE NORMAS TCNICAS.
NBR 9062 (1985). NBR 9062: Projeto e execuo de
A empresa LEONARDI Construo Industrializada pelo apoio ao estruturas de concreto pr-moldado. Rio de Janeiro.
desenvolvimento do projeto de pesquisa que gerou este artigo e [13] ASSOCIAO BRASILEIRA DE NORMAS TCNICAS.
FAPESP Fundao de Amparo a Pesquisa do Estado de So NBR 9062 (2006). NBR 9062: Projeto e execuo de
Paulo pelo apoio ao projeto temtico de pesquisa que englobou estruturas de concreto pr-moldado. Rio de Janeiro.
esse projeto de pesquisa. [14] Recommended practice for the design of prestressed
concrete columns and walls (1988). Journal of
7. Referncias bibliogrficas Presstressed Concrete Institute, Chicago, v.33, n. 4,
p. 56-95.
[01] ASSOCIAO BRASILEIRA DE NORMAS TCNICAS. [15] CARVALHO, R. C.; FIGUEIREDO, J. R. (2004).
NBR 6118 (2003). NBR 6118: Projeto de estruturas de Clculo e detalhamento de estruturas usuais de
concreto - Procedimento. Rio de Janeiro. concreto armado. So Carlos. EdUFSCar.
[02] HOGESLAG, A. J. (1990). Stability of precast concrete [16] FRANA, R.L.S. (1991). Contribuio ao estudo dos
structures. In: HOGESLAG, A. J.; VAMBERSKY, J. N. efeitos de segunda ordem em pilares de concreto
J. A.; WALRAVEN, J. C. Prefabrication of concrete armado. 232f. Tese (Doutorado) - Escola Politcnica,
structures (Proc. Int. Seminar Delft, The Netherlands, Universidade de So Paulo, So Paulo, 1991.
October, 25-26, 1990). Delft: Delft University Press, [17] ASSOCIAO BRASILEIRA DE NORMAS TCNICAS.
1990. p.29-40. NBR 8681 (2003). NBR 8681: Aes e segurana nas
[03] CHEFDEBIEN A. de & DALDARE J. (1994). estruturas - Procedimento. Rio de Janeiro.
Experimental investigations on current connections [18] FDRATION INTERNACIONALE DU BETON
between precast concrete components. COST C1 (1999). Structural concrete: textbook on behavior on