Académique Documents
Professionnel Documents
Culture Documents
Quick Selection
UK Special Edition
Contents
Quick Selection
UK Special Edition
1
Contents
This Quick Selection Guide has been designed to help you select the
products you require quickly and easily. It provides an overview of the
various product designs and dimensions for selected TROX products.
Full product details can be found in technical leaflets or the Easy Product
Finder software on our website - www.troxuk.co.uk
Components Systems
2
Contents
Introduction
Air velocity
The air velocity depends on variables such as
flow rate in combination with type and size of the diffuser
arrangement of the diffusers within the room
the height of the room
Drafts are caused by excessive air velocity in the occupied zone. The
configuration tables in this Quick Selection Guide have been chosen to
meet the most critical comfort criteria at a level exceeding that required
by European Standards.
The Quick Selection Guide contains the necessary data for calculating
the sound power levels. The Guide also allows selection of the
necessary attenuators.
3
Contents
Application
Room height up to 4 m
Flow
Air change Slot Swirl Blade Perforated
rate Grille
rates/h diffuser diffuser diffuser diffuser
control
KVS ++ ++ ++ ++ ++
10
VVS + + ++ + +
KVS ++* ++ ++ ++
10 20
VVS ++* ++ + +
KVS ++
20 30
VVS ++
Legend
++ very suitable
+ suitable
unsuitable
* flow discharge alternating horizontal!
Typical applications
Velocity / m.s-1
Typical noise
rating (NR)* Main ducts Branch Runouts
4
Contents
Table of Contents
5
Contents
Grilles
Type AH WAP AF
AH...-0 AH...-15
18 18
12.5
H + 41(21)/L + 41(21)
12,5
'H' - 4 / 'L' - 4
5,5
H/L
5,5
WAP...-0 WAP...-15
18 18
3,0
3,0
Type AF
Type AF-0 AF...-0 AF...-15
H+30/L+30 18 18
12.5
5,5
5,5
H/L
Rear Assembly
75
75
32
107
107
64
Order Code
Type L x H (mm)
AF Powder coat finish
AH
AHR (20mm border) Rear Assemblies Subframe Fixing
WAP A = Grille Face only 0 = No subframe 0 = Without (screwfix)
WAPR (20mm border) AG = Rear opposed B30 = 75mm subframe S11 = With (secret fix)
blade damper (30mm borders) for finite grille X = Without flange drilling
Blade deflection D = Rear adjustable B20 = as above but for 20mm
15 blades border grille
0 DG = Rear adjustable L30 = 1800mm subframe (30mm
blades and damper borders) for linear grille**
L20 = as above but for 20mm border grille
Note: ** = Also for use when S11 fix plenum box supplied
Order Code - Plaster In
Type L x H (mm)
- Linear Construction Powder coat finish
F Finite Construction
E End Section AHP-0
M Middle Section AHP-15
WAPP-0
WAPP-15
7
Contents
Grilles
Type AH WAP AF
75 78 111 136
100 113 160 195
Throw length correction
150 182 257 315
(for setting of blade divergence)
200 251 355 435
250 320 453 554
45 90
lS x 1.4 x 2.8
8
Contents
Grilles
Type AH WAP AF
lS x 1.4 x 2.8
9
Contents
Grilles
Type AT VAT
H + 22/L + 22
H + 45/L + 45
16,7
H/L
Type VAT 75 32 75
107 64 107
Nomenclature
Flow rate and throw distance
in l/s/m based on
V (l/s/m) 125 150 175 200 225 250 275 300 325 350 375 400 450 500 1000mm nominal grille
H (mm) ls(m) length.
100 5.1 6.1 7.2 8.2 9.2 H Nominal grille height.
150 5.6 6.4 7.1 7.9 8.7 9.5 10.3 11.1 11.9 ls in m = Throw distance
200 6.7 7.4 8.1 8.7 9.4 10.1 10.7 12.1 13.4 to a maximum time
250 7.7 8.3 8.9 9.5 10.7 11.8 averaged air velocity
300 8.6 9.7 10.7 of 0.7m/s
350 9.9
Volume flow rates apply to
a nominal grille length [L] of
Flow rate and throw distance 1000mm, maximum sound
V (l/s/m) 550 600 650 700 750 800 850 900 950 1000 1100 1200 1300 1400 power level of the air
H (mm) ls(m) regenerated noise of 40 dB(A)
250 13.0 14.2 15.4 with an open damper unit
300 11.8 12.8 13.9 15.0 16.1 17.2 (unrestricted airflow) and
350 10.8 11.8 12.8 13.8 14.8 15.8 16.8 17.8 18.7 maximum 15Pa pressure drop.
400 10.1 11.0 11.9 12.9 13.8 14.7 15.6 16.5 17.4 19.0
450 10.4 11.2 12.1 12.9 13.8 14.7 15.5 16.4 17.3 19.0
500 11.4 12.2 13.1 13.9 14.7 15.5 16.3 17.9 19.6
550 11.7 12.4 13.2 14.0 14.8 15.5 17.1 18.6 20.2
600 11.9 12.6 13.4 14.1 14.8 16.3 17.8 19.3 20.8
Order Code AT - AG / 800 x 200 / B30 / S11 / P3 / RAL 9010 / 20% Gloss
Grilles
Type AGS
3 1
Performance Data
Neck Pressure Drop (Pa) 3 7 12.5 19.5 28
Size (l/s) (LWA) (l/s) (LWA) (l/s) (LWA) (l/s) (LWA) (l/s) (LWA)
Order Code
11
Contents
Grilles
Type AR
Type AR Type AR
Rear Assembly
H + 22/L + 22
H + 45/L + 45
75
107
16,7
H/L
...-AG
Opposed blade action volume
control damper, adjustable from the
front face.
Aerodynamic data
Length (mm)
H(mm) Data
200 300 400 500 600 700 800 900 1000 1100 1200
min max 15 - 28 21 - 39 30 - 56 39 - 73 48 - 90 57 - 106 66 - 123 72 - 134 84 - 263 93 - 174 102 - 190
100 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 7 - 19 8 - 20 10 - 22 11 - 23 12 - 24 13 - 25 13 - 25 14 - 26 14 - 26 15 - 27 15 - 27
min max 24 - 45 39 - 73 54 - 101 69 - 129 84 - 157 99 - 185 114 - 213 129 - 241 141 - 263 156 - 291 171 - 319
150 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 9 - 21 11 - 23 12 - 24 13 - 25 14 - 26 15 - 27 16 - 28 16 - 28 16 - 29 17 - 29 17 - 29
min max 33 - 62 57 - 106 78 - 146 99 - 185 120 - 224 138 - 258 159 - 297 177 - 330 198 - 370 219 - 409 246 - 459
200 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 10 - 22 13 - 25 14 - 26 15 - 27 16 - 28 16 - 28 17 - 29 17 - 30 18 - 30 18 - 30 19 - 31
min max 72 - 134 96 - 179 123 - 230 150 - 280 174 - 325 198 - 370 222 - 414 249 - 465 273 - 510 306 - 571
250 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 14 - 26 15 - 27 16 - 28 17 - 29 17 - 29 18 - 30 18 - 31 19 - 31 19 - 31 20 - 32
min max 93 - 174 123 - 230 159 - 297 189 - 353 222 - 414 252 - 470 291 - 543 324 - 605 357 - 666 390 - 728
300 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 15 - 27 16 - 28 17 - 29 18 - 30 18 - 31 19 - 31 20 - 32 20 - 32 20 - 33 21 - 33
min max 150 - 280 189 - 353 228 - 426 264 - 493 303 - 566 339 - 633 378 - 706 417 - 778 465 - 868
350 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 17 - 29 18 - 30 19 - 31 19 - 31 20 - 32 20 - 32 21 - 33 21 - 33 22 - 34
min max 174 - 325 216 - 403 258 - 482 303 - 566 345 - 644 390 - 728 444 - 829 489 - 913 534 - 997
400 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 17 - 29 18 - 30 19 - 31 20 - 32 20 - 32 21 - 33 21 - 34 22 - 34 22 - 34
min max 258 - 482 309 - 577 360 - 672 411 - 767 462 - 862 528 - 986 579 - 1081 633 - 1182
450 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 19 - 31 20 - 32 21 - 33 21 - 33 22 - 34 22 - 34 23 - 35 23 - 35
min max 279 - 521 339 - 633 393 - 734 450 - 840 507 - 946 564 - 1053 618 - 1154 675 - 1260
500 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 19 - 32 20 - 32 21 - 33 21 - 34 22 - 34 22 - 35 23 - 35 23 - 35
min max 390 - 728 465 - 868 534 - 997 600 - 1120 666 - 1243 732 - 1366 1392 - 2598
600 Pa 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15 4 - 15
LWA 21 - 33 22 - 34 22 - 34 23 - 35 23 - 35 24 - 36 26 - 38
Nomenclature Note
min in l/s = Minimum flow rate In all cases, the max. pressure drop Pt = 15 Pa.
max in l/s = Maximum flow rate
Order Code
Fixing Variant
Rear Assemblies
0 = Without (screw fix)
A = Grille face only
X = Without flange drilling or secret fix
AG = Rear opposed blade damper
12
Contents
Grilles
Type AE AP
H+5/L+5
H/L
13
H + 41 / L + 41
H/L
100 TYP
Type AP
Type AE/AEL
Aerodynamic data
Length (mm)
H(mm) Data
200 300 400 500 600 700 800 900 1000 1100 1200
min max 27 - 59 42 - 91 57 - 124 72 - 156 87 - 189 102 - 221 117 - 254 132 - 286 147 - 540 162 - 351 177 - 384
100 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 12 - 28 14 - 30 15 - 31 16 - 32 17 - 33 18 - 34 18 - 35 19 - 35 19 - 36 20 - 36 20 - 36
min max 45 - 98 69 - 150 96 - 208 120 - 260 147 - 319 171 - 371 198 - 429 222 - 481 249 - 540 276 - 598 300 - 650
150 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 14 - 30 16 - 32 17 - 34 18 - 35 19 - 36 20 - 36 20 - 37 21 - 37 21 - 38 22 - 38 22 - 39
min max 63 - 137 99 - 215 135 - 293 171 - 371 207 - 449 243 - 527 279 - 605 315 - 683 351 - 761 387 - 839 423 - 917
200 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 16 - 32 17 - 34 19 - 35 20 - 36 21 - 37 21 - 38 22 - 38 23 - 39 23 - 39 23 - 40 24 - 40
min max 126 - 273 171 - 371 219 - 475 264 - 572 312 - 676 360 - 780 405 - 878 450 - 975 498 - 1079 543 - 1177
250 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 19 - 35 20 - 36 21 - 37 22 - 38 22 - 39 23 - 39 24 - 40 24 - 40 24 - 41 25 - 41
min max 156 - 338 213 - 462 267 - 579 324 - 702 384 - 832 426 - 923 495 - 1073 552 - 1196 609 - 1320 666 - 1443
300 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 19 - 36 21 - 37 22 - 38 23 - 39 23 - 40 24 - 40 24 - 41 25 - 41 25 - 42 26 - 42
min max 252 - 546 318 - 689 384 - 832 453 - 982 519 - 1125 585 - 1268 651 - 1411 720 - 1560 786 - 1703
350 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 22 - 38 23 - 39 23 - 40 24 - 40 25 - 41 25 - 42 26 - 42 26 - 42 26 - 43
min max 288 - 624 366 - 793 444 - 962 522 - 1131 600 - 1300 675 - 1463 753 - 1632 831 - 1801 909 - 1970
400 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 22 - 38 23 - 40 24 - 40 25 - 41 25 - 42 26 - 42 26 - 43 27 - 43 27 - 43
min max 426 - 923 504 - 1092 591 - 1281 678 - 1469 768 - 1664 855 - 1853 942 - 2041 1029 - 2230
450 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 24 - 40 25 - 41 25 - 42 26 - 42 26 - 43 27 - 43 27 - 44 28 - 44
min max 465 - 1008 564 - 1222 687 - 1489 759 - 1645 858 - 1859 957 - 2074 1053 - 2282 1155 - 2503
500 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 24 - 41 25 - 41 26 - 42 26 - 43 27 - 43 27 - 44 28 - 44 28 - 45
min max 681 - 1476 801 - 1736 918 - 1989 1038 - 2249 1158 - 2509 1275 - 2763 1392 - 3016
600 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 26 - 42 27 - 43 27 - 44 28 - 44 28 - 45 29 - 45 29 - 45
Nomenclature Note
min in l/s = Minimum flow rate In all cases, the max. pressure drop Pt = 15 Pa.
max in l/s = Maximum flow rate
13
Contents
Grilles
Type AE AP
Type AP/APL
Aerodynamic data
Length (mm)
H(mm) Data
200 300 400 500 600 700 800 900 1000 1100 1200
min max 15 - 33 21 - 46 30 - 65 39 - 85 48 - 104 57 - 124 66 - 143 72 - 156 84 - 306 93 - 202 102 - 221
100 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 9 - 26 11 - 27 12 - 29 13 - 30 14 - 31 15 - 31 16 - 32 16 - 32 17 - 33 17 - 34 18 - 34
min max 24 - 52 39 - 85 54 - 117 69 - 150 84 - 182 99 - 215 114 - 247 129 - 280 141 - 306 156 - 338 171 - 371
150 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 11 - 28 13 - 30 15 - 31 16 - 32 17 - 33 17 - 34 18 - 34 19 - 35 19 - 35 19 - 36 20 - 36
min max 33 - 72 57 - 124 78 - 169 99 - 215 120 - 260 138 - 299 159 - 345 177 - 384 198 - 429 219 - 475 246 - 533
200 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 13 - 29 15 - 31 16 - 33 17 - 34 18 - 35 19 - 35 20 - 36 20 - 36 20 - 37 21 - 37 21 - 38
min max 72 - 156 96 - 208 123 - 267 150 - 325 174 - 377 198 - 429 222 - 481 249 - 540 273 - 592 306 - 663
250 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 16 - 32 17 - 34 18 - 35 19 - 36 20 - 36 20 - 37 21 - 37 21 - 38 22 - 38 22 - 39
min max 93 - 202 123 - 267 159 - 345 189 - 410 222 - 481 252 - 546 291 - 631 324 - 702 357 - 774 390 - 845
300 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 17 - 34 18 - 35 20 - 36 20 - 37 21 - 37 22 - 38 22 - 39 23 - 39 23 - 39 23 - 40
min max 150 - 325 189 - 410 228 - 494 264 - 572 303 - 657 339 - 735 378 - 819 417 - 904 465 - 1008
350 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 19 - 36 20 - 37 21 - 37 22 - 38 22 - 39 23 - 39 23 - 40 24 - 40 24 - 41
min max 174 - 377 216 - 468 258 - 559 303 - 657 345 - 748 390 - 845 444 - 962 489 - 1060 534 - 1157
400 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 20 - 36 21 - 37 22 - 38 22 - 39 23 - 39 23 - 40 24 - 40 24 - 41 25 - 41
min max 258 - 559 309 - 670 360 - 780 411 - 891 462 - 1001 528 - 1144 579 - 1255 633 - 1372
450 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 22 - 38 22 - 39 23 - 39 24 - 40 24 - 41 25 - 41 25 - 42 26 - 42
min max 279 - 605 339 - 735 393 - 852 450 - 975 507 - 1099 564 - 1222 618 - 1339 675 - 1463
500 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 22 - 38 23 - 39 23 - 40 24 - 40 25 - 41 25 - 41 25 - 42 26 - 42
min max 390 - 845 465 - 1008 534 - 1157 600 - 1300 666 - 1443 732 - 1586 822 - 1781
600 Pa 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15 3 - 15
LWA 23 - 40 24 - 41 25 - 41 25 - 42 26 - 42 26 - 43 27 - 43
Nomenclature Note
min in l/s = Minimum flow rate In all cases, the max. pressure drop Pt = 15 Pa.
max in l/s = Maximum flow rate
Order Code
14
Contents
Grilles
Type LCG
Intumescent
mastic by others
LVV40 intumescent
fireblock
Order Code
Type L x H (mm)
LVV 40
LVH 44
Note: For use with LCG Grilles
15
Contents
Disc Valves
Type LVS Z-LVS
xE * xE *
xC xC
50
50
B
B
8
8
xD
xD
Order Code
Standard finish RAL 9010
LVS / 125 / G1
IEE
EE
Type Size
OE 100 TEE
Supply air Z-LVS EEE 125 EZ 0 without subframe
Extract air LVS P EEE G1 subframe (Standard) 1)
160
200
U
1) Unless otherwise specified on order,
equipment is delivered with subframe (G1).
16
Contents
Jet Nozzles
Type DUK
L1
9
D5
D3
D4
D1
D5
L2
DUK DUK-F DUK-V
Occupied zone
Nomenclature
X in m = Throw distance
Pt in Pa = Total pressure drop
Dimension of recess = D4 + 15 mm
Note
The combinations of flow rate and size as shown in the table
produce a sound power level:
LWA = 35 dB(A) for axial connection
LWA = 43 dB(A) for lateral connection
Order Code These codes need not be completed for standard products
K EE I EE P0 Powder coating
Duct connection element EE
A EEO
to RAL 9010 (GE 50 %)4)
Spigot
EE EZE P1
Duct connection element
E EE Powder coating
for circular ducting R3) EP EE to RAL 9006 (GE 30 %)4)
EE Other colours
IE U
External EE to RAL... (GE 70 %)4)
rotary actuator E1...E3 EEO
EE 1) For attachment without counterpunched holes: Supplementary text necessary for order
EE
Internal 2) For sizes 100 and 125, construction with actuator not available
linear actuator E4...E6 EP 3)
4)
Please indicate onsite duct diameter (R) as supplementary text
GE = Gloss level
17
Contents
Jet Nozzles
Type TJN
Nomenclature
X in m = Throw distance
pt in Pa = Total pressure drop
Note Occupied zone
The combinations of flow rate and size as shown in the table
produce a sound power level:
LWA = 35 dB(A) for axial connection
LWA = 43 dB(A) for lateral connection
Order Code
18
Contents
Jet Nozzles
Type DJ
DJ DJ DJ-OB
Nomenclature
Drum Jet Dimensions (mm)
X in m = Throw distance
Weight pt in Pa = Total pressure drop
Size A B W H C D E F J K
(Kg)
906 300 217 261 170 36 87 85 146 1.5 Note
1206 376 217 337 170 36 87 85 146 1.7 The combinations of flow rate and size as shown in the table
1806 529 217 490 170 36 87 85 146 2 produce a sound power level:
2406 681 217 642 170 36 87 85 146 2.5 LPNR = 40
2010 579 319 540 271 63 138 150 207 5.5
2510 706 319 667 271 63 138 150 207 6.5
3010 833 319 794 271 63 138 150 207 7.0
3510 960 319 921 271 63 138 150 207 7.5
Order Code
DJ - OB / DM / 906 / PC / RAL 9010 / 20% Gloss
IE
Type EE
DJ OE
EE Size Finish/colour
DJD DJ C/W Adjustable Blades EP 906
1206
Ancillaries 1806
OB Diffuser Mounted Opposed Blade Damper 2406
2010 Finish
OB/DM Duct Mounted OBD (Supplied loose)
2510 PC Powder Coated to RAL.... BS....
VED Diffuser Mounted Volume Equalising Deflector 3010
VED/DM Duct Mounted VC (Supplied loose) 3510
OB/VED Diffuser Mounted Volume Equalising Deflector with
opposed blade damper (add 50mm to required stub duct length)
OB/VED/DM Duct Mounted Volume Equalising Deflector with
opposed blade damper (add 50mm to required stub duct length)
(Supplied loose).
No entry - No ancillaries
19
Contents
Floor Diffusers
Type FB
D1
1 Diffuser core, ring spacing 6 mm
2 Trim ring with spring clips
D2
4.5
3 Height adjustable dirt trap 1
4 Swirl element
2
2
70
4
163
47
3
FB D3
Max noise level LWNC 40. Data for FBA diffusers and dirt trap, damper fully open no plenum box. Horizontal discharge is throw
distance to terminal velocity of 0.15m/s (min vol) and 0.25m/s (max vol). A 600mm clear zone (from centre of diffuser) is
recommmended with vertical discharge.
Discharge situation
Minimum distance Minimum distance
comfort zone
Mindestabstand comfort zone
Mindestabstand
600 mm 600 mm
tZ max = -6K
tZ max = -10K
horizontal vertical
(displacement flow) (mixed flow)
IEE
Dirt trap including
EE
for discharge control
TESM
EE
OE
adjustable flow rate Dirt trap including
EU
vertical V
EE
P
Adjustable swirl element2) control at face horizontal H adjustable flow rate
EE
IEE
for discharge control vertical fixed (3 control at rear
ZE
OE EESV
vertical V KF1) Trim ring Dirt trap including
P EE
horizontal H adjustable flow rate
vertical fixed (3 VF EU control at front
1) For orders without trim ring, a spacing ring is provided for technical
performance reasons and to ensure correct height
2) For orders without adjustable swirl element, the discharge direction is vertical KF1) Trim ring
3) Only available for size 200
20
Contents
Floor Grille
Type AFG
90mm Maximum
Pedestal
'A' u +0.5/-1mm Detail
13mm Nominal Pitch 6mm A
Min
25
AFG AFG-A AFG-AG
Sound power level and pressure drop Detail A (variable pedestal height)
.
V (l/s) 100 150 200 250 300 350 400 450 500
X
Damper Pt (Pa) Pt (Pa) Pt (Pa) Pt (Pa) Pt (Pa) Pt (Pa) Pt (Pa) Pt (Pa) Pt (Pa)
B
Position LWA LWA LWA LWA LWA LWA LWA LWA LWA
Shims to
suit height
C
1.1 2.4 4.3 6.6 9.4 12.6 16.4 20.6 25.3
100% required
<15 <15 18 24 31 36 41 44 47 (factory fitted)
1.4 3.0 5.3 8.2 11.7 15.8 20.6 25.9 32
50%
<15 <15 22 28 35 40 44 48 51
Impact load test: 13.5 kN load through 25mm Did not collapse
square indentor
40 kg Sand Bag from 1m Did not collapse
height
Type PEE
P2 Polyester powder coat silver grey
Size (mm) Not used
EE
OEE RAL 9006 25% Gloss (Standard)
EE P4 Polyester powder coat black
IE RAL 9005 20% Gloss
EE
Rear Assemblies
I
Face only A EOE
EE
PEE
Rear opposed blade damper AG EP EO
EE
Frame Depth (mm) between face of
grille and face of pedestal 25 standard
EI
Optionally 26 - 50 in 1mm steps
21
Contents
Slot Diffusers
Type VSD35
Diffuser layout Face Dimensions 'P' (mm)
flow discharge flow discharge
horizontal, one direction alternating horizontal No. of
NF FL TZ PL
slots
X A X
1 44 64 - -
2 71 91 - -
L H1 L 3 98 118 133 -
m
1.80m
1,80 m
4 124.5 144.5 - 299
1,80
1.80
VSD35 Tolerance Length L1 +/- 1
Width P +/- 1
Order Code
VSD35-V3-BF-4-FL- A02 / 1200 / 0 / P3 / RAL 9010 / 20% / HH2
Type
VSD35 Blade Setting
HH1 = All blades in one direction
Style
UE HH2 = Alternating blades every 300mm
Black White
EE End Cap HA2 = 45o Alternating blades every 150mm
BF WF EE 0 = No end plate/angle HH3 = Alternating blade 33%/66%.
BL WL E P0X1 = Plate 150mm then 300mm
BN WN A0X1 = Angle
TE TE Finish/colour
EZ
EE Fixings
BE WE EE L0X1 = Offset angle
EZE 0 = Without EE P3 = powder coated to RAL 9010 20%1
F=Finite EE PL0X1 = Plank EE EE P2 = powder coated to RAL 9006 25%
L=Linear 1) where X = 1 or 2 U FK = Fixing kit
ZE P4 = powder coated to RAL 9005 20%
E P6 = other colours to RAL
N=Non active
EE
E=Mitre* T Flange EE
NF= Not flanged U 1) standard finish
No. of Slots FL = Flanged
1 to 4 PL = Plank ceiling1
TE
TZ = Techzone2 EE Length L1 mm length of diffuser
1) 4 slot only EZ or angle* of mitre in degrees
2) VSD35 3 slot only EE *Only in 90o or 135o with 200mm
EU inside leg
22
Contents
Slot Diffusers
Type VSD35
Nomenclature Note
in l/s = Flow rate Room height = 2.8 m Sound power level is LWA 40 dB(A)
X in m = Throw distance H1 = <0.25 m/s Pressure drop Pt 15 Pa
L1 in mm = Length of plenum box
L = <0.5 m/s Alternating Blow based on 'X' = 1.0
A in m = Distance between 2 diffusers
'A' = 3.0
H1 in m/s = Time average air velocity between
2 diffusers
1) 1650, 1800 & 1950 long plenums c/w 2x 198 spigots
L in m/s = Time average upstream velocity at the wall
23
Contents
Slot Diffusers
Type VSD50
2 101.5 121.5 -
m
1.80m
1,80 m
4 185.5 205.5 299
1,80
1.80
VSD50 Tolerance Length L1 +/- 1
Width P +/- 1
Order Code
VSD50-V3-BF-4-FL- A02 / 1200 / 0 / P3 / RAL 9010 / 20% / HH2
Type
VSD50 Blade Setting
HH1 = All blades in one direction
Style UE HH2 = Alternating blades every 300mm
Black White E End Cap HA2 = 45o Alternating blades every 150mm
BF WF E 0 = No end plate/angle HH3 = Alternating blade 33%/66%.
BL WL EE P0X1 = Plate 150mm then 300mm
BN WN A0X1 = Angle
EZ TE
EE Fixings TE Finish/colour
BE WE L0X1 = Offset angle
EE P3 = powder coated to RAL 9010 20%1
EE EZE 0 = Without
F=Finite EE PL0X1 = Plank EE EE P2 = powder coated to RAL 9006 25%
L=Linear EE 1) where X = 1 or 2 U FK = Fixing kit
ZE P4 = powder coated to RAL 9005 20%
N=Non active ET EE P6 = other colours to RAL
E=Mitre* Flange
NF= Not flanged
EU 1) standard finish
No. of Slots FL = Flanged
1 to 4 PL = Plank ceiling1
TE
EE Length L1 mm length of diffuser
1) 3 & 4 slot only EZE or angle* of mitre in degrees
EE *Only in 90o or 135o with 200mm
U inside leg
24
Contents
Slot Diffusers
Type VSD50
Nomenclature Note
in l/s = Flow rate Room height = 2.8 m Sound power level is LWA 40 dB(A)
X in m = Throw distance H1 = <0.25 m/s Pressure drop Pt 15 Pa
L1 in mm = Length of plenum box
L = <0.5 m/s Alternating Blow based on 'X' = 1.0
A in m = Distance between 2 diffusers
'A' = 3.0
H1 in m/s = Time average air velocity between
2 diffusers
1) 1650, 1800 & 1950 long plenums c/w 2x 198 spigots
L in m/s = Time average upstream velocity at the wall
25
Contents
Slot Diffusers
Type AKV-VSD
W1 'X'
'W' 'X'
EXTENSION
45 A
AKV-VSD AKV-VSD
Plenum Length L - 300mm to 1500mm (150mm Increments) Plenum Length L - 1650mm, 1800mm , 1950mm (2 Spigots)
(2 Spigots available on request)
Order Code
AKV - VSD50 - V3 - 0 - 4 - D12 - M / 1200 x 1 x 198 x 0 / 279
IEE
OE
Type Assembled height
P
VSD35
VSD50
EPO Extended neck
EIE A = dimension mm
0 = without extended neck
IE
Plenum Type
EE
0 = Standard plenum EOE Spigot diameter
EH = Extended height EE
RA = Light baffle return air EP No. of Spigots
IEE PE
No. of Slots
OE Length
P
1 to 4
OE 450mm to 1800mm
IEE EPE
EI 150mm increments
OE
Lining EE Spigot Damper
P
- None OE 0= Standard spigot
D12 = 12mm E M = Spigot damper
EI MC = Cord operated
spigot damper
26
Contents
Slot Diffusers
Type ALS20
Diffuser layout
flow discharge flow discharge horizontal
horizontal, one direction two directions
Dimensions (mm)
No of A P
X A X Slots
1 41 769
2 80.5 115.5
3 120 155
L H1 L
4 159.5 194.5
m
1.80m
1,80 m
Tolerance
1,80
1.80
Length L1 +/- 1
ALS20 Width P +/- 1
DIM 'A' mm
DIM 'A'mm
2
76
75
75
28 2
28 20 28 28 20 19.5 20 28
SLOT SLOT SLOT
DIM 'P' mm DIM 'P'mm
Slot Diffusers
Type ALS20
Nomenclature Note
in l/s = Flow rate Room height = 2.8 m Sound power level is LWA 40 dB(A)
X in m = Throw distance H1 = <0.25 m/s Pressure drop Pt 15 Pa
L1 in mm = Length of plenum box
L = <0.5 m/s
A in m = Distance between 2 diffusers
H1 in m/s = Time average air velocity between 2 diffusers
L in m/s = Time average upstream velocity at the wall
28
Contents
Slot Diffusers
Type ALS25
Diffuser layout
flow discharge flow discharge horizontal
horizontal, one direction two directions
Dimensions (mm)
No of A P
X A X
Slots
1 46 81
2 90.5 125.5
L H1 L 3 135 170
4 179.5 214.5
m
1.80m
1,80 m
1,80
1.80
Tolerance
Length L1 +/- 1
ALS25 Width P +/- 1
DIM 'A' mm
DIM 'A'mm
2
76
75
75
28 2
28 25 28 28 25 19.5 25 28
SLOT SLOT SLOT
DIM 'P' mm DIM 'P'mm
Slot Diffusers
Type ALS25
Nomenclature Note
in l/s = Flow rate Room height = 2.8 m Sound power level is LWA 40 dB(A)
X in m = Throw distance H1 = <0.25 m/s Pressure drop Pt 15 Pa
L1 in mm = Length of plenum box
L = <0.5 m/s
A in m = Distance between 2 diffusers
H1 in m/s = Time average air velocity between 2 diffusers
L in m/s = Time average upstream velocity at the wall
30
Contents
Slot Diffusers
Type AKV-ALS
W X W X
Ec O/A HEIGHT
Eb O/A HEIGHT
(D+22)
(D+22)
D
D
Bb
Bc
TYPICAL SLOT
(VSD TYPE SHOWN)
D
Bb
2 176 92.5 110.5 (D+122) 298 (D+98)
AKV-ALS25
3 238 137 155 (D+122) 353 (D+98)
4 310 181.5 199.5 (D+122) 448 (D+98)
EXTENSION (*)
Extension Y Min. = 25mm All Types Max. = 700mm All Types Y
AKV-ALS
Spigot Lengths
Spigot Order Spigot Length Dimension X
Damper Suffix Up to 178 198 to 398
Order Code
AKV - ALS20 - 3 - BF - D - M / 1200 x 248 x 2 x 430 / 0 / 0
IEE
Variable OE Length Overall Height (mm)
Plenum P (mm)
IEE
Spigot
OEE
Diffuser Type (mm)
P
ALS20 Number of spigots
ALS25
Number of slots
IE
Fixing
EE M = Spigot Damper or no entry
CF = Clip fix EOE
BF = Bridge fix EE D = Lining or no entry
BX = Bridge fix for extended height plenum EP
31
Contents
Swirl Diffusers
Type SDW
8
598
8
8
no location pip
16
16
599 15 26 573
584 face size
1) Face section without central fixing hole, for use on lay in ceilings QL, QS15, QS26, QM15 & QM26 without rear plenum
32
Contents
Swirl Diffusers
Type SDW
Diffuser face
Cross bar
Suspension hole
Spigot
Lip seal
Damper blade for volume flow rate balancing
Pressure tap
Cord for closing the damper blade
Cord for opening the damper blade
SDW-Q Measuring tube
SDW-Q-...-H
W1 'X'
D
H1
33
Contents
Swirl Diffusers
Type SDW
SDW-Q
Nomenclature
Flow rate (l/s) Arrangement single-row
in l/s = Flow rate
A (m)
Size min in l/s = Minimum flow rate
0 1.2 1.8 2.4 3.0 3.6 4.2
A, B in m = Distance between two diffusers
300 x 8 60 60 60 60 60 60 60
400 x 16 104 102 100 104 104 104 104
500 x 24 133 133 122 124 133 133 133
Note
600 x 24 188 150 146 160 188 188 188 In all cases, the sound power level is LWA 40 dB(A) per
600 x 48 226 180 170 180 226 226 226 diffuser and the pressure drop Pt 40 Pa.
625 x 24 188 150 146 160 188 188 188
Selection valid for ceiling height = 2.7...3 m.
625 x 54 232 196 180 190 232 232 232
300 x 8 60 60 60 60 60 60
625 x 54 145
400 x 16 88 86 94 102 104 104
500 x 24 110 100 104 108 130 130
600 x 24 3.6 128 126 138 154 180 186
600 x 48 150 140 152 160 180 226
625 x 24 128 126 138 154 180 186
625 x 54 164 150 166 178 200 232
300 x 8 60 60 60 60 60 60
400 x 16 102 100 104 104 104 104
500 x 24 130 122 124 122 130 130
600 x 24 4.2 150 146 160 180 186 186
600 x 48 180 170 180 190 226 226
625 x 24 150 146 160 180 186 186
625 x 54 194 180 190 210 232 232
34
Contents
Swirl Diffusers
Type XARTO
Diffuser face
Central fixing screw
Swirl unit (for supply air only)
Damper blade for volume flow rate balancing
Spigot
Double lip seal
Suspension lug
Equalising element (for supply air only)
Cross bar
XARTO-Q1
Nominal Size Q1 H1 D3 H3 D A C
Nominal Size Q1 H1 D3 H3 D A C
35
Contents
Swirl Diffusers
Type XARTO
Nominal Size Q1 H1 D3 H3 D A C
Nomenclature
in l/s = Flow rate
min in l/s = Minimum flow rate Diffuser layout
A, B in m = Distance between two diffusers
1/2 A
A A
Note
In all cases, the sound power level is LWA 40 dB(A) per
diffuser and the pressure drop Pt 45 Pa.
B
36
Contents
Swirl Diffusers
Type XARTO
Quick sizing tables provide a good overview of the volume flow rates and corresponding sound power levels and differential
pressures.
The minimum volume flow rates apply to a supply air to room air temperature difference of 6 K.
The maximum volume flow rates apply to a sound power level of approx. 50 dB (A) with damper blade position 0.
Order Code
XARTO - Q4 - Z / 600 / P1 - RAL ...
TE
EE
Type No entry: powder-coated RAL 9010,
IE pure white
EE
Size
Circular (R1...R4) R* EE 600 Q, D
EOE
Square (Q1...Q6)
Circular (C1...C6)
Q*
C*
EE
EP
625 Q only
EEZ P1 Powder-coated,
EE
specify RAL CLASSIC colour
IE
EEO EE Gloss level
EE
Supply Z RAL 9010 50 %
EE
Extract A EP RAL 9006 30 %
U All other RAL colours 70 %
37
Contents
Swirl Diffusers
Type RFD
wK
40
H2
A
U4
U2
R2 R2
Q2 Q2
R2
w Q2
200 33 33 39 45 53 58 250 30
2.4 315 55
250 33 33 43 56 64 70
315 64 80 93 103 400 75
1/2B
IEE Size TE 0
Square Q OE EE Standard finish
Circular R P EE powder coated
EEZ to RAL 9010 (GE 50 %)1)
EE P1
Nozzle D
EE Powder coating
IE EE to RAL 9006 (GE 30 %)1)
Collar K EE U Other colours
Top entry plenum US EOE to RAL... (GE 70 %)1)
EE
Plenum box A EP 1) GE = Gloss level
38
Contents
Swirl Diffusers
Type RFD
RFD-R-D
Schematic illustration of the RFD-R-D, with plenum box for horizontal duct connection
Diffuser face
Central fixing screw
Plenum box
Cross bar
Suspension hole
Spigot
39
Contents
11 w 11
K
xD
H1
xD
xA
H3
H2
H2
8
8
w 593 (w 598, w 623) w 593 (w 598, w 623) w 593 (w 598, w 623)
200 56 56 50 46 54 60 250 30
2.4 315 55
250 54 54 54 56 66 75
315 80 80 80 80 92 104 400 75
1/2B
40
Contents
DCS-P
Diffuser face
Discharge nozzle
Blade
Plenum box
Suspension lug
Spigot
41
Contents
Swirl Diffusers
Type VDL
mK
D1
D5
H7
D1
H5
H4
D4
H3(M)
H2(X)
H8
65
H6
H1
A
A
D3 D3
D2 D2
D3
D2
Dimensions (mm)
Size A D1 D2 D3 D4 D5 H1 H2 H3 H4 H5 H6 H7 H8 K
315 42 313 464 381 317 248 145 92 80 215 474 150 282 290 435
400 45 398 567 468 402 313 157 101 89 236 581 168 368 351 500
630 51 628 871 700 628 398 204 117 105 367 812 293 468 526 750
800 55 798 1077 871 798 498 229 123 111 538 1081 458 568 741 1000
Nomenclature Note
in l/s = Flow rate B = >5m
min in l/s = Minimum flow rate H1 = < 0.2 m/s
H in m = Room height L = 0.4 m/s
H1 in m = Distance between discharge level and occupied zone Xmin = 2m
H1 in m = jet penetration distance, vertical discharge,
in heating operation
Amin, B in m = Distance between 2 diffusers Selection valid for ceiling height 3.8 m to 6.8 m
Xmin in m = Distance from wall
H1 in m/s = time average air velocity between 2 diffusers
L in m/s = time average air velocity at the wall
LWA in dB(A) = Sound power level
pt in Pa = Pressure drop
Order code These codes need not be completed for standard products
Specify colour
Size Not used
EPE
IEE 0 Standard finish
OE
EE
Discharge ring without flange A powder coated
P
EE
Discharge ring with flange B EE to RAL 9010 (GE 50 %)3)
IE OEE
Side entry spigot H EEO EE P1 Powder coating
Top entry spigot V EE EPE to RAL 9006 (GE 30 %)3)
EP M manually adjustable
EE
Diffuser face only F EE EE Other colours
EOE E1 electric actuator, 230 V, 50 Hz I to RAL... (GE 70 %)3)
With lip seal L1) EE E2 electric actuator, 24 V, 50 Hz
IEE E3 electric actuator, 24 V, 50 Hz, 2...10 V
OE
Diffuser face not removable N1)
EE
P X fixed blades (for horizontal flow discharge only)
I
Diffuser face removable D1)
IEE 1) only in combination with constructions H and V
With square collar K2) OE 2) only in combination with discharge ring B
With protection grid S2) P 3) GE = Gloss level
42
Contents
Ceiling Diffusers
Type ADT
ADTF l l l l l l l
ADTA l l l l l l
ADTB l l l l l l
ADTT l l l l l l l
ADTM l l
ADTS l l
ADT
53
53
53
Z
15
To fit ceiling opening size (L / H +100) To lay-on ceiling T supports. To suit threadline support bar ceiling
.
ADTM : 'Z' = 16mm / ADTS : 'Z' = 8mm
ADTA / ADTB
Detail LxH
X&Y Detail X ADTA PIP heights Detail Y ADTB PIP heights
25
15
7
43
Contents
Ceiling Diffusers
Type ADT
Dimensions (mm)
Size D K E X
150 148/1231 148 322 40 / 752
225 198 223 372 40 / 1002
300 248 298 422 40 / 1002
375 348 373 522 40 / 1002
450 398 448 572 40 / 1002
525 398 523 572 40 / 1002
600 398 598 572 40 / 1002
K X K
25
D
40
Option
type M1)
D
'E' O/A height
Option Option
242
type AGP type AGP
Variable Diffuser
Plenum Size (mm) Overall Height (mm)
(including diffuser)1)
Spigot Dia (mm)
0 No lining
D Lining
44
Contents
Ceiling Diffusers
Type ADT
Nomenclature
in l/s = Volume flow per diffuser
L in m = Distance from the outlet where the
maximum time average air velocity is 0.5 m/s
Pt in Pa = Total pressure drop
LWA = Sound power level in dB(A)
ADT
Type ADT performance data (without damper, if fitted, 100% open) based on diffuser & side entry
plenum box
Supply Extract
. .
Nominal Vmin pt LWA VL0.5 Nominal Vmin pt LWA
Size l/s m/h Pa dB(A) m Size l/s m/h Pa dB(A)
25 90 16 22 0.8 25 90 10 20
30 108 23 27 0.9 30 108 14 25
150 150
35 126 31 32 1.0 35 126 19 30
40 144 40 36 1.2 40 144 25 33
35 126 6 <15 1.0 35 126 4 <15
55 198 14 22 1.2 55 198 10 21
225 225
75 270 25 31 1.4 75 270 18 30
95 342 41 38 1.8 95 342 28 38
60 216 6 <15 0.8 60 216 4 16
95 342 14 23 1.5 95 342 10 28
300 300
130 468 26 33 2.1 130 468 20 37
160 576 40 39 2.6 160 576 30 42
90 324 4 <15 1.0 90 324 6 19
160 576 14 28 2.0 160 576 17 34
375 375
220 792 27 37 2.7 220 792 32 43
270 972 40 42 3.5 270 972 49 49
135 486 5 15 1.0 135 486 4 17
235 846 15 30 2.5 235 846 12 34
450 450
310 1116 26 37 3.4 310 1116 21 42
380 1368 39 43 4.1 380 1368 31 48
180 648 6 15 1.6 180 648 4 19
275 990 14 26 2.6 275 990 10 31
525 525
370 1332 26 35 3.4 370 1332 18 39
455 1638 40 40 4.1 455 1638 28 45
230 828 7 15 2.1 230 828 5 19
340 1224 15 26 2.9 340 1224 10 31
600 600
445 1602 26 34 3.7 445 1602 18 39
550 1980 40 41 4.3 550 1980 27 45
Note
The throw distance L should be between 75% and 100% of If selecting using blanking plates the selected diffuser
the distance to the nearest wall or 50% of the diffuser nominal size should be based on the following:
spacing dimension, based on a ceiling height of 2.7 - 2.9m. 3-way selection - 133% of design volume.
2-way corner selection - 200% of design volume.
Use the volume based on the 4-way discharge
performance data shown in the table below
45
Contents
Ceiling Diffusers
Type DLQ/ADLQ
K 50
D
H
DLQ/ADLQ DLQ-AK DLQ-AG
Note
A/2
In all cases, the sound power level is LWA 40 dB(A) per diffuser
Selection valid for ceiling height = 2.7...3 m.
Order Code These codes need not be completed for standard products
46
Contents
Ceiling Diffusers
Type ADLR
B
D
K
D
H2
H1
35
6
/ /
Order Code These codes need not be completed for standard products
47
Contents
Ceiling Diffuser
Type ADM
A section AG section
70
45
50
7
12.5
12.5 Overall size
Blade Pitch
Blade Pitch
30 'H'-22 / 'L'-22 30 ADMR 'H' - 2 / 'L' - 2
Overall size 'H' + 38 / 'L' + 38 ADML 'H' - 5 / 'L' - 5
Fixing Arrangements
Supply Aerodynamic Data ADM-1
H Pressure Drop (Pa)
in mm Type X - Standard Supply Type S11
<10 <10 12 20 28 38
Volume (l/s/m) 80 120 160 200 240 280 Opening Opening size
150 size ('H' / 'L') ('H'+6 / 'L'+6)
Throw (m) 3.3 5.0 6.7 8.4 10.0 11.7
Volume (l/s/m) 120 180 240 300 360
200 Border drilled for fixing to
Throw (m) 4.1 6.1 8.2 10.2 12.3 duct / ceiling (by others)
Volume (l/s/m) 160 240 320 400
250
Throw (m) 4.7 7.1 9.5 11.8
Volume (l/s/m) 200 300 400
35
300
Throw (m) 5.3 7.9 10.6
Volume (l/s/m) 240 360 480
350
Throw (m) 5.8 8.7 11.6
Volume (l/s/m) 280 420
400
Throw (m) 6.2 9.4
Type N1 - Support bar for duct mounting
Volume (l/s/m) 320 480
450 Support bar supplied loose
Throw (m) 6.7 10.0 Opening size 'H' x 'L' for screw fixing into duct
(by others)
Type ...- AG
Duct
Type ...-A
Supply Aerodynamic Data ADM-2
140
70
H Pressure Drop (Pa)
in mm <10 <10 12 20 28 38
Volume (l/s/m) 60 90 120 150 180 210
150
Throw (m) 2.0 3.0 4.1 5.1 6.1 7.2
Volume (l/s/m) 100 150 200 250 300 350
200 Type N2 - Support bar for plenum mounting
Throw (m) 2.6 3.9 5.3 6.6 7.9 9.2
Volume (l/s/m) 140 210 280 350 420 490 Plenum I/S size 'H'-9 x 'L'-9 Support bar supplied loose
250 for screw fixing into duct
Throw (m) 3.1 4.7 6.2 7.8 9.4 11.0
(by others)
Volume (l/s/m) 180 270 360 450 540
300 Plenum
Throw (m) 3.5 5.3 7.1 8.9 10.6
Volume (l/s/m) 220 330 440 550 660
350
Throw (m) 3.9 5.9 7.8 9.8 11.8
Volume (l/s/m) 260 390 520 650
400
Throw (m) 4.2 6.4 8.5 10.7
Volume (l/s/m) 300 450 600 750
450
Throw (m) 4.6 6.9 9.2 11.5
The above selections meet noise levels up to and including NC35 assuming 8dB room attenuation. ADM linear diffuser with ceiling effect (horizontal throw).
Throw is the distance from diffuser to a velocity of 0.5 m/s. For ADMR/ADML effective height for performance = 'H' - 50mm.
Order Code
ADM- 2 - A G / LxH / L30 / S11 / P3 / RAL 9010 / 20% Gloss
IEE
OE
Type ADM Sizes available Powder coat finish
P
ADMR PEE
ADML EEE X Without
S11 Secret fastener
IEE Without installation subframe 0
EEE
Directions 1
OE N1 Support bar for duct mounting
P
of discharge 2 With installation subframe L30
OE N2 Support bar for plenum mounting
(Only for S11 fixing option)
EEE
Q Alignment & support angle(2
IEE EEE
OE
(Not suitable for plenum mounting) QN2 Alignment & support angle c/w
Basic construction A EI
Ancillaries AG(1 P support bar for plenum mounting(2
Note
(1 AG damper not used in conjunction with N1 fixing.
(1 ADM units supplied with TROX AK plenums - AG damper must be included within plenum
(2 Q, QN2 fixing options only available for type ADMR.
48
Contents
Ceiling Diffusers
Type VDR
mK
B2
D
45
D
H2
H8
H6
H1
H3
H5
R R
Note
B = >5m
H1 = < 0.2 m/s
L = 0.4 m/s
Xmin = 3m
Selection valid for ceiling height 3.8 m to 6.8 m
Order Code These codes need not be completed for standard products
IEE
Top entry spigot V OEE Not used Specify colour
Side entry spigot H P Size
IE
230 V, 50 Hz,
E1 EE
Open-Closed control EE EPEE 0 Standard finish
EE EEE
24 V, 50 Hz,
E2 EOE EEE powder coated
Open-Closed control EE EOE to RAL 9010 (GE 50 %)1)
EE EE P1 Powder coating
24 V, 2...10 V-,
EE EEEE to RAL 9006 (GE 30 %)1)
Constant modulating E3 EP EEE Other colours
control EIE to RAL... (GE 70 %)1)
1) GE = Gloss level
49
Contents
D2
4
A
C
DLQL DLQL ...-H DLQL ...-V
Dimensions (mm)
DLQL-P DLQL-T
Nominal Size D1 D2 H1 Q3 H2 H4 A C
Q1
DLQL-T: Q1 = 618 is available for T-bar ceilings with grid size 625
DLQL-P : Q1 to 623 mm available
Nomenclature
in l/s = Flow rate
min in l/s = Minimum flow rate
A in m = Minimum distance between two diffusers
Note
In all cases, the sound power level is LWA 40 dB(A) per
diffuser.
Selection valid for ceiling height = 2.7...3 m.
Diffuser layout
Minimum distance between two diffusers (A)
.
Flow rate V (l/s)
Size A/2
40 50 60 70 80 90 100 110 120 140 160 180 200 A
250 1.6 1.8
300 1.7 2.0
400 1.7 1.8 2.1 2.3
A
50
Contents
Note the noise levels quoted are the dBA rating of sound power level LWA.
To obtain typical room levels LPA LWA 5 dB.
Order Code
TE
Type
Nominal
T-bar ceiling
I
T EE
EO
Diffuser EE No entry: powder-coated RAL 9010,
EE P1
pure white
Grid or plasterboard EE Size
P EEP
Powder-coated,
ceiling (mm)
EEZ specify RAL CLASSIC colour
IEE EE
Supply Air Z
OE
P EE Gloss level
EE
Extract Air A RAL 9010 50 %
RAL 9006 30 %
Horizontal duct connection H IEE
OE
Size of diffuser
face plate (mm)
U All other RAL colours 70 %
Vertical duct connection V P DLQL-P
No entry: size of diffuser
IEE
No entry: None -
OE face plate = nominal size 2 mm
Adjustable flow rate control M P 598
623
For grid size 600
For grid size 625
(only for connection type H)
... Other dimensions, 623 mm max.
IEE DLQL-T
No entry: None -
OE 593 For T-bar ceilings, grid size 600
Spigot c/w lip seal L P 618 For T-bar ceilings, grid size 625
51
Contents
x 8.5
20 20
x
x
x 8.5
150 150
90 165
90 165
38
180
38
180
Description
JZ-P JZ-LL-A2 (airtight to DIN 1946)*
Casing and blades made from galvanised rolled steel sheet, Same as Type JZ-LL, except:
casing flanges with holes in the corners on both sides Casing, blades and external linkage made from stainless steel,
Blade spindles and external linkage made from galvanised steel type No. 1.4301, casing flanges with holes in the corners on
Plain bearings made from special plastic both sides
Parallel blade operation Blade spindles made from stainless steel, type No. 1.4305
Drive arm may be located on any blade
Temperature resistant to 100 C
JZ-P-A2 Standard sizes
Casing, blades and external linkage made from stainless steel,
type No. 1.4301, casing flanges with holes in the corners on B H
both sides (mm) (mm)
Blade spindles made from stainless steel, type No. 1.4305 400 345
Plain bearings made from special plastic
600 510
H
Parallel blade operation
Drive arm may be located on any blade 800 675
Temperature resistant to 100 C
1000 840
JZ-S
Same as Type JZ-P, except: Opposed blade operation 1200 1005
JZ-S-A2 1400 1170
Same as Type JZ-P-A2, except: Opposed blade operation 1600 1335
JZ-HL 1800 1500 B
Same as Type JZ-S, except:
Additional seals on long blade sides 2000 1665
Temperature resistant to 90 C 1830
JZ-LL (airtight to DIN 1946)* 1995
Same as Type JZ-S, except:
Seals on long blade sides made from special plastic, side seals All combinations of B and H dimensions can be supplied.
made from foam plastic Within the standard dimension range, all intermediate dimensions
Drive arm may be located on every 2nd blade (B dimension and/or H dimension) available.
Temperature resistant to 90 C Multileaf damper variants outside the standard dimension range are
* Leakage < 10 m3/h / m2 blades closed at pressure differential of 100 Pa supplied subdivided on B or H dimension.
52
Contents
Multileaf Dampers
JZ-AL JZ-LL-AL
20
x
H/B
x 8.5
100
50 150
38
120
JZ-AL . JZ-LL-AL
Order Code
JZ AL / 1100950 / ER / Z64 / NC / P1 RAL ...
53
Contents
50
50
(Types A and B) (Types C and D)
H + 100
H
82.5
82.5
A C
H
B
H
B
B D
B
83 ~ 15 95 ~ 15
B + 100
WG WG WG-A2 WG-AL
The sound power levels LWA apply to external weather louvres with a flow cross section of 1m2
Description
WG WG-AL WG-A2
Frames and blades of formed, galvanised Frames and blades of extruded Frames, blades and bird screen
steel sheet aluminium sections (mesh size 20 x 20 mm) in stainless steel,
Bird screen using 20 x 20 mm galvanised type No. 1.4301(Opt. insect screen -
wire mesh (Opt. insect screen - Bird screen using 20 x 20 mm galvanised
wire mesh (Opt. insect screen - 1.25 x 1.25)
1.25 x 1.25)
Flange drilled as standard 1.25 x 1.25) Flange drilled as standard
Free cross section approx. 60 % rel. Flange drilled as standard Free cross section approx. 60 % rel.
to B x (H 0.085 m) to B x (H 0.085 m)
Free cross section approx. 60 % rel.
to B x (H 0.085 m)
54
Contents
28
(Types A and B) (Types C and D)
H + 56
H
25
A C
H
B
H
B
B D
B
B + 56
34 ~8
WGK WGK
Description
WGK
Frames and blades of extruded aluminium sections, natural Flange drilled as standard
anodised (E6-C-0) Free cross section approx. 60 % rel. to B x (H 0.028 m)
Bird screen using 6 x 6 mm galvanised wire mesh
(Opt. insect screen - 1.25 x 1.25)
Order Code
WG - AL - 2 - U / 600 x 1155 / ER / P1 - RAL ...
IE
EE
TE Surface
Type
EOE
WG
EE
EP EE
EE
WGK (... -AL only) No entry: standard construction
Material IE
EE Nominal size (mm) EE (WGK-AL standard construction
55
Contents
35
H
35
L = 375 resp. 500
FK-EU with fusible link FK-EU with spring return actuator
Class of performance to EN 13501-3, DoP/FK-EU/DE/2013/001
up to EI 120 (8 h0 i - 0) S
250 35 250 319 389 458 528 597 653 722 778 847 903 958 1028 778 875 958 1056 1153 1236 1333
45 361 458 556 639 736 833 917 1000 1097 1181 1264 1347 1431 1111 1236 1375 1500 1625 1764 1889
300 35 319 403 486 569 653 736 819 889 972 1042 1125 1194 1264 1014 1139 1250 1375 1486 1611 1722
45 444 569 694 806 917 1028 1139 1250 1347 1458 1569 1667 1778 1444 1611 1778 1958 2125 2292 2458
350 35 389 486 583 681 778 875 972 1056 1153 1236 1333 1417 1500 1250 1403 1542 1681 1833 1972 2125
45 542 681 819 958 1097 1222 1347 1486 1611 1736 1861 1986 2097 1778 1986 2194 2403 2611 2806 3014
400 35 444 569 681 792 903 1014 1125 1222 1333 1431 1528 1639 1736 1486 1653 1819 2000 2167 2347 2514
45 625 792 958 1111 1264 1417 1569 1708 1861 2000 2139 2292 2431 2111 2347 2597 2833 3083 3333 3569
450 35 347 458 514 611 708 819 917 1014 1111 1208 1306 1417 1514 1708 1903 2111 2306 2500 2694 2903
45 500 667 722 875 1014 1153 1292 1444 1583 1722 1861 2000 2153 2431 2708 3000 3278 3556 3833 4125
500 35 431 583 583 694 806 917 1028 1153 1264 1375 1486 1597 1708 1931 2167 2389 2611 2833 3056 3278
45 611 819 819 986 1153 1306 1472 1625 1792 1958 2111 2278 2431 2750 3069 3389 3708 4028 4347 4667
550 35 653 778 903 1028 1153 1278 1403 1528 1653 1792 1917 2167 2417 2667 2917 3167 3417 3653
45 917 1097 1278 1458 1639 1819 2000 2181 2361 2542 2722 3069 3431 3778 4139 4500 4847 5208
600 35 722 861 1000 1139 1278 1417 1556 1694 1833 1972 2111 2389 2667 2931 3208 3486 3764 4042
45 1014 1222 1417 1611 1819 2014 2208 2403 2611 2806 3000 3389 3778 4181 4569 4958 5347 5736
650 35 792 944 1097 1250 1403 1556 1708 1847 2000 2153 2306 2611 2917 3208 3514 3819 4111 4417
45 1111 1333 1556 1764 1986 2208 2417 2639 2847 3069 3278 3708 4139 4569 4986 5417 5847 6278
700 35 847 1014 1181 1347 1514 1681 1847 2014 2181 2347 2500 2833 3153 3486 3806 4139 4458 4792
45 1208 1444 1681 1917 2153 2389 2625 2861 3097 3333 3556 4028 4486 4958 5417 5875 6347 6806
750 35 917 1097 1278 1458 1639 1819 2000 2167 2347 2528 2694 3056 3403 3764 4111 4458 4806 5167
45 1306 1569 1819 2069 2333 2583 2833 3083 3333 3583 3833 4347 4847 5347 5847 6333 6833 7333
800 35 986 1181 1375 1569 1764 1944 2139 2333 2514 2708 2903 3278 3653 4028 4403 4778 5153 5528
45 1403 1681 1958 2222 2500 2764 3042 3306 3583 3847 4125 4653 5194 5722 6264 6792 7333 7861
Nomenclature
in l/s = Flow rate
Pt in Pa = Total pressure drop
LWA in dB(A) = Sound power level
Order Code
185 30 B 30
30
H
30
approx.
ca. 70
L = 300
70
Order Code
57
Contents
420
370
50 50 150
70
D
Class of performance to EN 13501-3,
FKR-EU with fusible link up to EI 120 (8 h0 i - 0) S DoP/FK-EU/DE/2013/001
ZEE TQ
See leaflet T 224 None, no entry required
250
EE Dry motarless installation kit
IE 280
U See leaflet
Construction variants EE 315
Standard, no entry required EE
Powder-coated casing -1 EE Nominal size
Stainless steel casing -2 EE Accessories 1
EOE None, no entry required
EE
Coated damper blade -7 SO - AS
Powder-coated casing and EE See leaflet
Coated damper blade -1-7 EE
Stainless steel casing and EE
Coated damper blade -2-7 EP
58
Contents
L = 400
270
220
50 50 approx.
80
NW
FKRS-EU with fusible link DoP/FK-EU/DE/2013/002
59
Contents
Fire Dampers
Attachments
1) Code for attachments only for galvanised fire dampers (e. g. -EU).
The attachments (exception: flexible connectors) are supplied in galvanised construction
Flexible connectors are identical for all construction variants.
2) Code for attachments only for fire dampers with powder coating RAL 7001 (e. g. ...-EU-1).
The attachments are supplied with powder coating RAL 7001. Flexible connectors are identical for all construction variants.
3) Code for attachments only for stainless steel fire dampers (e. g. ...-EU-2).
The attachments are supplied with powder coating RAL 7001, exception: extension pieces for Type FKS-EU are supplied in stainless steel construction.
Flexible connectors are identical for all construction variants.
4) and the corresponding extension piece (if required, depending on height and size).
5) and the corresponding extension pieces (if required, depending on height and size).
6) Only for casing length L = 375 mm.
7) Only for casing length L = 500 mm.
8) The flexible connectors are supplied loose.
9) The fire dampers are supplied with pre-mounted extension piece and/or with pre-mounted cover grille.
10) Only for casing lengths L = 500 mm (FKR-01-K90) and. L = 600 mm (FKR-02-K90).
60
Contents
Fire Dampers
Accessories
FKS-EU FKRS-EU
61
Contents
70 L 70
10,5
10.5
20
Da
B
50
max.120
max. 600 Maximum space required for H
actuator/control components
TVZ
Nomenclature
Dimensions (mm)
Pst in Pa = Static pressure differential
in l/s = Volume flow rate TVZ TVA TVZD TVAD*
Size
LpA in dB(A) = A-weighted sound pressure level of air-regenerated B H L B H L
noise, system attenuation taken into account 125 300 236 1035 380 316 1075
LpA1 in dB(A) = A-weighted sound pressure level of air-regenerated 160 410 236 1035 490 316 1075
noise with TX silencer, system attenuation taken
200 560 281 1320 640 361 1360
into account
LpA2 in dB(A) = A-weighted sound pressure level of case-radiated 250 700 311 1440 780 391 1480
noise, system attenuation taken into account 315 900 361 1440 980 441 1480
LpA3 in dB(A) = A-weighted sound pressure level of case-radiated 400 1000 446 1820 1080 526 1860
noise with additional acoustic cladding, system
attenuation taken into account * with acoustic cladding
62
Contents
20 B 20
M8
H
M238FG1
L B
B
~ 80
TZ-Silenzio
Nomenclature
Dimensions (mm)
Pst in Pa = Static pressure differential
in l/s = Volume flow rate TZ-Silenzio TZ-Silenzio-D
Size 3 3 3
LpA in dB(A) = A-weighted sound pressure level of air-regenerated B H L B H3 L
noise, system attenuation taken into account 125 300 236 1035 380 316 1075
LpA1 in dB(A) = A-weighted sound pressure level of air-regenerated 160 410 236 1035 490 316 1075
noise with TX silencer, system attenuation taken
200 560 281 1250 640 361 1250
into account
LpA2 in dB(A) = A-weighted sound pressure level of case-radiated 250 700 311 1250 780 391 1250
noise, system attenuation taken into account 315 900 361 1250 980 441 1250
LpA3 in dB(A) = A-weighted sound pressure level of case-radiated * with acoustic cladding
noise with additional acoustic cladding, system
attenuation taken into account
System attenuation: See leaflet K5-1.5-1
63
Contents
20 B 20
M8
H
L B
B
~ 80
TA-Silenzio
Nomenclature
Dimensions (mm)
Pst in Pa = Static pressure differential
in l/s = Volume flow rate TA-Silenzio TA-Silenzio-D
Size 3 3 3
LpA in dB(A) = A-weighted sound pressure level of air-regenerated B H L B H3 L
noise, system attenuation taken into account 125 300 236 1035 380 316 1075
LpA1 in dB(A) = A-weighted sound pressure level of air-regenerated 160 410 236 1035 490 316 1075
noise with TX silencer, system attenuation taken
200 560 281 1250 640 361 1250
into account
LpA2 in dB(A) = A-weighted sound pressure level of case-radiated 250 700 311 1250 780 391 1250
noise, system attenuation taken into account 315 900 361 1250 980 441 1250
LpA3 in dB(A) = A-weighted sound pressure level of case-radiated * with acoustic cladding
noise with additional acoustic cladding, system
attenuation taken into account
System attenuation: See leaflet K5-1.5-1
64
Contents
TVR
(mm) (l/s) (l/s) LpA LpA1 LpA2 LpA3 LpA LpA1 LpA2 LpA3
100 99 10 95 40 42 27 21 15 48 29 28 21
125 124 15 150 60 42 28 22 15 47 32 28 20
160 159 25 250 100 44 32 24 16 51 37 31 23
200 199 40 405 155 45 31 26 15 49 36 31 17
250 249 60 615 245 45 32 34 16 48 36 36 20
315 314 105 1030 390 44 32 35 17 49 37 40 22
400 399 170 1680 625 40 28 32 18 47 35 40 23
Nomenclature
Pg in Pa = Total pressure differential
in l/s = Volume flow rate
LpA in dB(A) = A-weighted sound pressure level of air-regenerated
noise, system attenuation taken into account
LpA1 in dB(A) = A-weighted sound pressure level of air-regenerated
noise with CS silencer, system attenuation taken
into account
LpA2 in dB(A) = A-weighted sound pressure level of case-radiated
noise, system attenuation taken into account
LpA3 in dB(A) = A-weighted sound pressure level of case-radiated
noise with additional acoustic cladding, system
attenuation taken into account
System attenuation: See leaflet K5-1.5-1
65
Contents
TVR-Easy
(mm) (l/s) (l/s) LpA LpA1 LpA2 LpA3 LpA LpA1 LpA2 LpA3
100 99 10 95 40 42 27 21 15 48 29 28 21
125 124 15 150 60 42 28 22 15 47 32 28 20
160 159 25 250 100 44 32 24 16 51 37 31 23
200 199 40 405 155 45 31 26 15 49 36 31 17
250 249 60 615 245 45 32 34 16 48 36 36 20
315 314 105 1030 390 44 32 35 17 49 37 40 22
400 399 170 1680 625 40 28 32 18 47 35 40 23
Nomenclature
Dimensions (mm)
Pg in Pa = Total pressure differential
Size Da L
in l/s = Volume flow rate
100 99 310
LpA in dB(A) = A-weighted sound pressure level of air-regenerated
noise, system attenuation taken into account 125 124 310
LpA1 in dB(A) = A-weighted sound pressure level of air-regenerated 160 159 400
noise with CS silencer, system attenuation taken 200 199 400
into account
250 249 400
LpA2 in dB(A) = A-weighted sound pressure level of case-radiated
noise, system attenuation taken into account 315 314 500
LpA3 in dB(A) = A-weighted sound pressure level of case-radiated 400 399 500
noise with additional acoustic cladding, system
attenuation taken into account
System attenuation: See leaflet K5-1.5-1
IE TE Accessories
Type EEO EE
VAV Controller TVR-Easy EE Size ZE 00 without
with acoustic cladding TVRD-Easy EP 100 EU D2 lip seal
125
160
200
250
315
400
66
Contents
38
H
approx. 70
Slot 20 x 13
approx. 70
TVJ TVT-Easy
OE
LpA2 in dB(A) = A-weighted sound pressure level of case-radiated noise, system attenuation
with acoustic cladding TVJD-Easy
EE
taken into account
LpA3 in dB(A) = A-weighted sound pressure level of case-radiated noise with additional
VAV Controller, airtight TVT-Easy
EE acoustic cladding, system attenuation taken into account
with acoustic cladding TVTD-Easy P System attenuation: See leaflet K5-1.5-1
67
Contents
VARYCONTROL
Type VAV-EasySet
60 45 45
VAV-EasySet
Measuring location
>>0,5
0.5 D
D
>> 1,5
1.5 D
D >2D >2D
Maximum
tube length of 3 m
per measuring line
Order Code
VAV-EasySet
Type
68
Contents
TVR
69
Contents
KSFS KSF
ED
TFM TFW
70
Contents
50 Dimensions (mm)
D Da L
80 79 310
100 99 310
Da
174 2)
125 124 310
160 159 310
200 199 310
approx. 250 249 400
L 1) 70
315 314 400
Lip seal optional 1) RNS: L = 250
2) RNS: 110 400 399 400
RN
(mm) (l/s) (l/s) LpA LpA1 LpA2 LpA3 LpA LpA1 LpA2 LpA3
80 79 11 45 25 39 16 22 < 43 20 26 <
100 99 22 90 40 39 19 19 < 43 23 23 <
125 124 35 140 60 41 25 17 < 45 29 21 <
160 159 60 240 100 44 30 31 < 48 34 35 <
200 199 90 360 155 42 26 30 < 46 30 34 <
250 249 145 580 245 41 27 31 < 45 31 35 <
315 314 230 920 390 40 27 32 < 44 31 36 15
400 399 350 1400 625 46 34 46 16 50 38 50 20
IE
Type
EEO Size Actuators
Volume flow controller RN EE See leaflet
with acoustic cladding RND EP
IE
Material EE
Basic construction, steel, galv. 00 EOE
Surface powder-coated P1 EE
Colour RAL 7001 EP
Type TE Accessories
Size EE
Volume flow controller RNS
ZE 00 without
80
100
EU D2 lip seal on both ends1)
IE
Material EE 125
Basic construction, steel, galv. 00 EOE
Surface powder-coated P1 EE 1) Nominal size 80 on RNS and RN-P1 with adapter
Colour RAL 7001 EP
71
Contents
H
38
Longitudinal 400
B
hole 20 x 13
38
EN
Actuators
IE
Type EEO BxH See leaflet
Volume flow controller EN EE
with acoustic cladding END EP
72
Contents
Circular Silencers
Type CA CF CS
xda
xD
100 0.008 99 100 160 211
125 0.012 124 125 191 235
160 0.020 159 160 221 271
75 75 200 0.031 199 200 261 311
L
250 0.050 249 250 311 366
315 0.079 314 315 376 476
400 0.126 399 400 461 511
CA CF
Insertion loss (dB) for L = 1500 mm Insertion loss (dB) for L = 1500 mm
fm, oct. (Hz) fm, oct. (Hz)
D D
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
250 4 11 21 37 41 27 15 12 80 11 14 33 48 50 50 47 37
315 3 9 18 34 35 21 10 9 100 10 11 27 44 50 50 37 30
400 3 7 16 32 31 16 7 7 125 7 9 21 41 50 46 33 27
450 2 6 15 31 29 14 6 6 160 5 7 17 37 48 42 24 19
500 2 6 14 30 27 13 5 6 200 4 6 14 37 48 34 18 15
560 2 5 13 29 25 11 4 5 250 3 5 11 35 45 25 14 11
630 2 5 12 28 23 10 4 4 315 2 4 10 26 35 19 12 10
710 2 5 11 27 22 9 3 4 400 2 4 9 20 26 17 11 8
800 2 4 11 26 20 8 2 3
Nomenclature
fm, oct. in Hz = Octave band centre frequency
NW = Size
L = Length
Insulation thickness in mm 1)
Size
Length in mm
Not required
Connection variations
000 = Plug type spigots
VD2 = Lip seal on both ends
1) Insulation thickness 25 and 50 mm available. (If the insulation thickness is not specified on the order, thickness 50 mm is delivered as standard.)
73
Contents
Circular Silencers
Type CB
xD
xd
(m2) (mm) (mm) (mm) holes
100 0.008 99 132 25 x 3 4
125 0.012 124 157 25 x 3 4
160 0.020 159 192 25 x 4 6
L
200 0.031 199 233 25 x 4 6
Insulation thickness 50 mm: D = d + 100 mm 250 0.050 249 283 25 x 4 6
Insulation thickness 100 mm: D = d + 200 mm
1) Low-leakage performance to DIN V 24194 Part 2, Class II without
315 0.079 314 352 30 x 4 8
additional on-site seals. Available up to and including size 400 400 0.126 399 438 30 x 4 8
450 0.158 448 488 30 x 4 8
CB CB 500 0.198 498 538 30 x 4 8
560 0.251 558 600 35 x 4 12
CB 100; Insulation thickness = 100 mm 630 0.316 628 670 35 x 4 12
710 0.397 708 750 35 x 4 12
Insertion loss (dB) for L = 1000 mm 800 0.499 798 840 35 x 4 16
900 0.628 898 940 35 x 4 16
fm, oct. (Hz)
D 1000 0.785 998 1041 35 x 4 16
63 125 250 500 1k 2k 4k 8k
250 5 10 17 30 47 50 50 36
315 4 9 15 27 44 45 39 27
400 3 7 13 25 40 38 29 21
Selection table
450 3 7 12 24 39 35 26 18
. Upstream Airway-
500 2 6 12 23 38 33 24 17 D Flow rate V velocity velocity pt L WA
560 2 6 11 22 36 31 21 15
l/s m3/h m/s m/s Pa dB(A)
630 2 5 11 21 34 29 19 13
250 287 1035 6 9.9 41 44
710 2 5 10 20 33 27 17 12
315 459 1651 6 9.9 37 45
800 2 5 9 19 31 25 14 10
400 743 2674 6 9.9 33 45
900 2 4 9 18 30 23 13 9
450 942 3390 6 9.9 32 46
1000 2 4 8 17 29 22 12 8
500 1164 4190 6 9.9 31 46
560 1462 5263 6 9.9 30 46
Insertion loss (dB) for L = 1500 mm 630 1853 6669 6 9.9 29 47
fm, oct. (Hz) 710 2355 8480 6 9.9 28 47
D 800 2993 10776 6 9.9 27 47
63 125 250 500 1k 2k 4k 8k
900 3792 13650 6 9.9 27 48
250 7 14 22 41 50 50 50 44
1000 4684 16863 6 9.9 26 48
315 7 12 20 37 50 50 50 34
400 6 10 17 33 50 50 40 26 Pt in Pa = Total pressure loss for L = 1000 mm
450 5 9 16 31 50 50 36 23
500 5 9 16 30 50 50 33 21
560 4 8 15 30 50 48 29 19
630 4 8 14 29 50 44 26 16
710 4 7 13 28 50 41 23 14
800 3 6 13 26 49 37 20 12
900 3 6 12 24 47 34 17 11
1000 3 6 11 23 45 33 16 10
Nomenclature
fm, oct. in Hz = Octave band centre frequency
NW = Size
L = Length
Order Code
Example: CB 100 / 315 x 1000 / GZ / VF2
TE
Type 1) EE Connection variations
EZE 000 = Plug-type spigots
Insulation thickness in mm 2) EE VF2 = Flange on both ends 3)
EU VD2 = Lip seal both ends 4)
Size TE
EE Matching flange(s)
Length in mm ZE 00 = none
EE
1) On Type CB: Coned end = air inlet end
U GZ = both ends
2) Insulation thickness 50 mm possible up to size 400 (if no insulation thickness is specified on order, thickness 100 mm is delivered as standard)
3) Flange on both ends: L-20 mm
4) Lip seal on both ends available for size 100...400
74
Contents
Splitter Attenuator
Type MSA 200
H
L B
Combination (Width/Height) at Pt approx. 50 Pa; Air-regenerated noise max. 46 dB(A) per m2 at L = 1500 mm
(l /s)
16,000
0 ,n8
240
B=
14,000 7
0, n
210
B=
12,000 ,n6
1800
B=
n5
10,000 500 ,
B=1
8,000 0 0, n4
B = 12
,n3
6,000 B = 900
2
4,000 B = 600, n
2,000 B = 300, n 1
0
300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800
n = number of splitters H (mm)
Nomenclature
fm in Hz = Octave band centre frequency
Pt in Pa = Total pressure drop
Order Code Splitter Attenuator in m3/h = Flow rate
X-CUBE
With the TROX X-CUBE, an air handling unit with unlimited configuration options, TROX sets a new standard in the AHU market
and defines considerably higher levels of quality, performance, flexibility, reliability, energy efficiency, and hygiene. Compelling all
down the line. TROX now offers everything from a single source: air handling units and components ideally complementary to
each other.
For even more energy efficiency and better quality with less coordination effort.
Key Features:
Eurovent certified; ErP ready
For the ventilation of rooms and entire buildings, for filtering,
heating, and cooling the air, for heat recovery as well as for
humidification and dehumidification, and for volume flow
rates of up to 86,000 m/h
Flexible frame construction, completely covered externally
by thermally insulated panels or doors
Easy installation, maintenance and cleaning
Integrated digital controls (Modbus or Bacnet) providing
factory configure plug and play easy to install solutions
with reduced cabling.
Special hygiene construction variant for use in hospitals
and laboratories
Weatherproof construction variant for outdoor installation
76
Contents
L1
12
D
H
A
B
DID614 DID614
Active chilled beam with four-way air discharge and horizontal heat exchanger, suitable for grid ceilings with grid size 600 or 625.
Active chilled beam for heating and cooling, with 2-pipe or 4-pipe heat exchanger, for integration with various ceiling systems.
Preferably for room heights up to 4.20 m
High heating and cooling capacity with a low conditioned primary air volume flow rate and low sound power level
High comfort levels due to low airflow velocity in the occupied zone
Five nozzle variants, including a variant with adjustable twin nozzles to optimise induction based on demand
Removable induced air grille, fixed with magnets, with decreasing apertures towards the edges
Order Code
584
Y
H
HS
B
8
LN 62
L
Dimensions (mm)
LN L
DID642 DID642
900 893 - 1500
1200 1193 - 1800
Dimensions (mm) 1500 1493 - 2100
D H HS 1800 1793 - 2400
Active chilled beam with two-way air discharge and horizontal heat exchanger, suitable for grid ceilings with grid size 600 or 625.
Active chilled beam for heating and cooling, with 2-pipe or 4-pipe heat exchanger, for integration with various ceiling systems.
Preferably for room heights up to 4.0 m
High heating and cooling capacity with a low conditioned primary air volume flow rate and low sound power level
High comfort levels due to low airflow velocity in the occupied zone
Five nozzle variants, including a variant with adjustable twin nozzles to optimise induction based on demand
Hinge down or removable induced air grille, with decreasing apertures towards the edges
Order Code
78
Contents
A LH A
Dimensions (mm)
60
L 1000, 1500, 2000, 2500, 3000
B 295, 455, 575
H
Passive chilled beam in nominal lengths of up to 3000 mm and with a horizontal heat exchanger.
Passive chilled beam with 2-pipe heat exchanger for ceiling installation, either freely suspended or above an open cell ceiling.
Preferably for room heights from 2.6m
Comfortable room cooling
Water connection from the side or top
3 standard widths and heights for optimum dissipation of heat loads
Order Code
79
Contents
The latest advance in chilled beam technology combines aesthetic flexibility with economical functionality to produce the next
generation in building services systems. Designed around one of TROXs active or passive chilled beam units, beam casings
incorporate high grade architectural extrusion and the opportunity for the inclusion of integrated mechanical services to meet a
clients bespoke needs.
Key advantages:
Shorter construction period
Earlier amortisation of the investment for the owner
Easy installation (plug and play)
Significant reduction of interfaces on site
Good quality of the system due to factory assembly
of the components
TROX UK has comprehensive testing facilities which allows for the manufacture and testing of a full size sample in a mock-up
setting. Key criteria are confirmed by the in-house laboratory including: thermal, photometric, aerodynamic and acoustic
requirements.
80
Contents
Fancoil
TROX Controls
The fancoils can be supplied with standard factory fitted, and fully tested controls package that is suitable for BacNet
compatibility.
Testing
TROX have an in house, BSRIA approved test laboratory where all the PWH units are rigorously tested to the latest standards.
The fancoils for a particular project can be witness tested to prove the given duties.
There are many variables, please enquire with TROX UK office for full computer selections.
81
Contents
Headquarters Germany
TROX GmbH Phone +49(0)28 45 / 2 02-0
Heinrich-TROX-Platz Fax +49(0)28 45 / 2 02-2 65
E-Mail trox@trox.de
D-47504 Neukirchen-Vluyn www.troxtechnik.com
UK Subsidiary
TROX UK Ltd Phone +44 (0)1842 754545
Caxton Way Fax +44 (0) 1842 763051
Thetford E-Mail sales@troxuk.co.uk
IP24 3SQ www.troxuk.co.uk
Subsidiaries
Argentina France Russia
TROX Argentina S.A. TROX France Sarl OOO TROX RUS
Australia Great Britain Serbia
TROX Australia Pty Ltd TROX UK Ltd. TROX Austria GmbH
Austria Hong Kong South Africa
TROX Austria GmbH TROX Hong Kong Ltd. TROX South Africa (Pty) Ltd
Belgium Hungary Spain
S.A. TROX Belgium N.V. TROX Austria GmbH TROX Espaa, S.A.
Brazil India Sweden
TROX do Brasil Ltda. TROX INDIA PRIVATE LIMITED TROX Sverige AB
Bulgaria Italy Switzerland
TROX Austria GmbH TROX Italia S.p.A. TROX HESCO Schweiz AG
China Malaysia Turkey
TROX Air Conditioning Components TROX Malaysia Sdn. Bhd. TROX TURKEY TEKNIK
(Suzhou) Co., Ltd. Norway KLIMA SAN. Ve TIC. LTD. STI
Croatia TROX Auranor Norge AS United Arab Emirates
TROX Austria GmbH Poland TROX Middle East (LLC)
Design changes reserved: All rights reserved TROX UK (2016 r2)
International Representatives
Abu Dhabi Indonesia Lithuania Portugal Uruguay
Bosnia-Herzegovina Iran Mexico Saudi Arabia Venezuela
Chile Ireland Morocco Slovak Republic Vietnam
Cyprus Israel Netherlands Slovenia Zimbabwe
Egypt Jordan New Zealand Sweden
Finland Korea Oman Taiwan
Greece Latvia Pakistan Thailand
Iceland Lebanon Philippines Ukraine