Labko Oil Separator Systems Labko Oil Separator Systems

Wavin-Labko in brief
Wavin-Labko Ltd is a Finnish company with over 40 years'
experience in developing, manufacturing and marketing of
measurement devices and various plastic products. In the field
of measurement devices we are specialized in level instruments
and alarm devices, automation and identification, and in web-
based solutions of data transfer. In the field of plastic products
we have focused our know-how on wastewater and stormwater
treatment by using various separator systems. These systems
cover the separator solutions in business and services
construction, the wastewater treatment in rural area settlements,
as well as the wastewater treatment of private houses and
summer cottages.

Wavin-Labko Ltd is a part of international Wavin Group, which


is the leader in the European market for plastic pipe systems.
Wavin Group has a presence in 27 European countries.

Wavin-Labko Ltd reserves the rights to alterations without prior notice. Due to policy of continuous
improvement in R&D, technical specifications may change. Installation shall always be made as
documented in manufacturer's instructions.
FOR STORMWATER TREATMENT
Pictorino Oy/Kirjapaino Hermes 1/2006 2.000

IN INDUSTRIAL, STORAGE AND


TRAFFIC AREAS

www.wavin-labko.fi
Wavin-Labko Ltd
Labkotie 1
FI-36240 Kangasala
FINLAND
Tel. int. +358 20 1285 200
Fax int. +358 20 1285 280
E-mail tanks@wavin-labko.fi

Reliable solutions Separators and tanks


Labko Oil Separator Systems Labko Oil Separator Systems
Labko Bypass System

Labko Bypass System

At this point the flow rate has not reached In environmentally sensitive areas or in

Labko Many hazardous substances, such as oil


and heavy metals, are carried from surfaced
areas into the environment. Up to 80 % of
Operation and structure of the
Labko Bypass System
Within the Labko Bypass System the peak
its maximum yet, letting the separators in
the Labko Bypass System process all the
Direct areas, which for some other reason require
100 % cleaning of the rainwater, it is

Bypass heavy metals are combined with solid matter,


such as sand and silt, which are carried
flow of the stormwater is directed through the
Labko FRW Flow Regulation Well to pass the
rainwater. The following peak flow that
contains fewer pollutants is directed past system reasonable to use the traditional, so called
direct system. This system is dimensioned

System for along with the rainwater. separator system consisting of the EuroHEK the separator system. Thus, the washout to treat the entire downpour, thus requiring
sand and sludge trap and the EuroPEK oil of the separator is prevented, and oil will larger separators and causing more
To save nature from harmful emissions the separator. Following the separator system not be carried from the separator to the substantial building costs than the Labko

stormwater rainwater flowing from surfaced areas should


be cleaned. In general, the areas from which
there is the EuroNOK FRW sampling shaft,
in which the bypass line is reconnected with
sewer system, which normally leads the
rainwater to the ground.
Bypass System.

treatment the rainwater is collected are relatively large,


for example car parks, industrial areas, traffic
areas, terminals, or airfields. Environmentally
the rainwater line. In spite of the bypass flow,
a well dimensioned Labko Bypass System
treats approximately 95 % of the annual
Considerable savings are obtained by using
Labko Bypass System, in comparison with
most delicate areas should be equipped downfall. Thanks to the Labko Bypass cleaning systems, which are sized to treat
prevents the washout of
with a system processing all the downfall. System, stormwater treatment is not only the whole nominal flow. Smaller and more
the separator system
In normal conditions it is possible to reduce effective, but cost-effective, too. economical separators can be used in a
during heavy downpour
the investment costs by using Labko Bypass Labko Bypass System than in a direct
economical solution for System. Efficient and cost-effective system.
stormwater treatment in stormwater treatment
EuroHEK sand
It is a research observation that most of the and sludge trap
large areas
oils and heavy metals carried with the rainwater
treats 95 % of the annual from surfaced areas are mainly washed away EuroPEK
EuroNOK FRW
rainfall sampling shaft with
at the beginning of the downpour. oil separator
a shut-off valve

TEGRA 600
inspection well Wavin
HEK 400 TEL

Wavin
HEK 400 TEL Wavin SandSET-1000 Labcom 200
TEGRA 600 Labko FRW HEK 400 TEL sand sludge alarm communication unit
inspection well Flow Regulation and sludge trap
Well

Wavin OilSET-1000
HEK 400 TEL oil alarm
sand and
sludge trap

Designed for use in


parking lots
industrial yards and storage areas
traffic areas EuroHEK sand
terminals and sludge trap
airfields
EuroNOK FRW
sampling shaft with
EuroPEK a shut-off valve
Labko Bypass System oil separator

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
2 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 3
Labko Oil Separator Systems Labko Oil Separator Systems
Labko Bypass System

Labko Bypass System

At this point the flow rate has not reached In environmentally sensitive areas or in

Labko Many hazardous substances, such as oil


and heavy metals, are carried from surfaced
areas into the environment. Up to 80 % of
Operation and structure of the
Labko Bypass System
Within the Labko Bypass System the peak
its maximum yet, letting the separators in
the Labko Bypass System process all the
Direct areas, which for some other reason require
100 % cleaning of the rainwater, it is

Bypass heavy metals are combined with solid matter,


such as sand and silt, which are carried
flow of the stormwater is directed through the
Labko FRW Flow Regulation Well to pass the
rainwater. The following peak flow that
contains fewer pollutants is directed past system reasonable to use the traditional, so called
direct system. This system is dimensioned

System for along with the rainwater. separator system consisting of the EuroHEK the separator system. Thus, the washout to treat the entire downpour, thus requiring
sand and sludge trap and the EuroPEK oil of the separator is prevented, and oil will larger separators and causing more
To save nature from harmful emissions the separator. Following the separator system not be carried from the separator to the substantial building costs than the Labko

stormwater rainwater flowing from surfaced areas should


be cleaned. In general, the areas from which
there is the EuroNOK FRW sampling shaft,
in which the bypass line is reconnected with
sewer system, which normally leads the
rainwater to the ground.
Bypass System.

treatment the rainwater is collected are relatively large,


for example car parks, industrial areas, traffic
areas, terminals, or airfields. Environmentally
the rainwater line. In spite of the bypass flow,
a well dimensioned Labko Bypass System
treats approximately 95 % of the annual
Considerable savings are obtained by using
Labko Bypass System, in comparison with
most delicate areas should be equipped downfall. Thanks to the Labko Bypass cleaning systems, which are sized to treat
prevents the washout of
with a system processing all the downfall. System, stormwater treatment is not only the whole nominal flow. Smaller and more
the separator system
In normal conditions it is possible to reduce effective, but cost-effective, too. economical separators can be used in a
during heavy downpour
the investment costs by using Labko Bypass Labko Bypass System than in a direct
economical solution for System. Efficient and cost-effective system.
stormwater treatment in stormwater treatment
EuroHEK sand
It is a research observation that most of the and sludge trap
large areas
oils and heavy metals carried with the rainwater
treats 95 % of the annual from surfaced areas are mainly washed away EuroPEK
EuroNOK FRW
rainfall sampling shaft with
at the beginning of the downpour. oil separator
a shut-off valve

TEGRA 600
inspection well Wavin
HEK 400 TEL

Wavin
HEK 400 TEL Wavin SandSET-1000 Labcom 200
TEGRA 600 Labko FRW HEK 400 TEL sand sludge alarm communication unit
inspection well Flow Regulation and sludge trap
Well

Wavin OilSET-1000
HEK 400 TEL oil alarm
sand and
sludge trap

Designed for use in


parking lots
industrial yards and storage areas
traffic areas EuroHEK sand
terminals and sludge trap
airfields
EuroNOK FRW
sampling shaft with
EuroPEK a shut-off valve
Labko Bypass System oil separator

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
2 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 3
Labko Oil Separator Systems Labko Oil Separator Systems

Labko FRW Flow Regulation Well EuroHEK sand and sludge trap EuroHEK Omega sand and sludge trap


Labko EuroHEK
During a heavy downpour, the Labko FRW In EuroHEK sand and sludge trap the sand The larger EuroHEK Omega 20005000
Flow Regulation Well adjusts and restricts carried by the rainwater is separated. Thus, and EuroHEK 650050000 are the sand
the incoming flow to the separator system. the sand and sludge trap contributes to the and sludge traps for e.g. parking lots.

FRW Flow The Labko FRW Flow Regulation Well


contains a mechanical flow regulator, which and smooth operation of the oil separator and
to lower maintenance costs. The rainwater SandSET-1000 sludge alarm controls the

Regulation provides an even flow into the separators,


even if the incoming flow should exceed
the dimensioned flow of the separator EuroHEK
to be treated flows into the sand and sludge
trap, which separates sand, sludge and
further solids from the water. The solid-free
filling of the sludge storage space and
indicates an alarm when the sand and sludge
trap must be emptied (some 1/3 of the water

Well system. The excess flow is directed via


the bypass pipe to pass the separator During normal downfall all the rainwater is
directed through the separator. The figure
Omega rainwater flows from the sand and sludge
trap into the oil separator. According to the
capacity is filled with sand). The timely
emptying of the sand and sludge trap
system. This prevents the washout of the EN 858 standard, a sand and sludge trap ensures the proper functioning of the oil
gathered sands and oils in the separator
system. Labko FRW Flow Regulation Well
presents the early phase of a heavy downpour,
during which the FRW flow regulation
mechanism starts to function. The flow
Sand and is always a part of the oil separator system. separator. SandSET-1000 is provided as a
standard in EuroHEK 10000 and larger sand

Sludge
is dimensioned to process approximately regulator only allows the maximal rainwater EuroHEK 6001500 sand and sludge traps and sludge traps. For smaller sand and
95% of the annual downpour. amount corresponding to the dimensioned are designed for stormwater treatment in sludge traps the SandSET-1000 is available
flow into the separator system. The excess parking areas, petrol station filling areas and as an accessory.
flow is shortly dammed, until let flow via
bypass pipe past the separator system. Traps in yard areas.

The rainwater from surfaced areas carries


sand and finer-grained sludge. Most of the
heavy metals occurring in traffic areas are
bound to these solid particles.

Flow rate

Concentration of
oil and solids
Also during the peak flow of the heavy
downpour the separator system functions
Time normally. The Labko FRW Flow Regulation
Well leads the excess flow exceeding the
First Flush phenomenon: Most of the oils and heavy metals carried by the rainwater are dimensioned flow of the oil separator via the
flushed from surfaced areas during the first phase of the downpour. At this point, the bypass pipe to pass the separator system.
rainwater flow has not reached its maximum yet, allowing all the rainwater flow though Thus the washout of the separators is
the separators of the Labko Bypass System. prevented.

SandSET-1000 SET-2000
sludge alarm oil alarm

Labko FRW
Flow Regulation EuroHEK Omega EuroPEK EuroNOK FRW
Well sand and sludge Omega Filter sampling shaft with
separator oil separator a shut-off valve

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
6 +358 20 1285 200 -358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 7
Labko Oil Separator Systems Labko Oil Separator Systems

Labko FRW Flow Regulation Well EuroHEK sand and sludge trap EuroHEK Omega sand and sludge trap


Labko EuroHEK
During a heavy downpour, the Labko FRW In EuroHEK sand and sludge trap the sand The larger EuroHEK Omega 20005000
Flow Regulation Well adjusts and restricts carried by the rainwater is separated. Thus, and EuroHEK 650050000 are the sand
the incoming flow to the separator system. the sand and sludge trap contributes to the and sludge traps for e.g. parking lots.

FRW Flow The Labko FRW Flow Regulation Well


contains a mechanical flow regulator, which and smooth operation of the oil separator and
to lower maintenance costs. The rainwater SandSET-1000 sludge alarm controls the

Regulation provides an even flow into the separators,


even if the incoming flow should exceed
the dimensioned flow of the separator EuroHEK
to be treated flows into the sand and sludge
trap, which separates sand, sludge and
further solids from the water. The solid-free
filling of the sludge storage space and
indicates an alarm when the sand and sludge
trap must be emptied (some 1/3 of the water

Well system. The excess flow is directed via


the bypass pipe to pass the separator During normal downfall all the rainwater is
directed through the separator. The figure
Omega rainwater flows from the sand and sludge
trap into the oil separator. According to the
capacity is filled with sand). The timely
emptying of the sand and sludge trap
system. This prevents the washout of the EN 858 standard, a sand and sludge trap ensures the proper functioning of the oil
gathered sands and oils in the separator
system. Labko FRW Flow Regulation Well
presents the early phase of a heavy downpour,
during which the FRW flow regulation
mechanism starts to function. The flow
Sand and is always a part of the oil separator system. separator. SandSET-1000 is provided as a
standard in EuroHEK 10000 and larger sand

Sludge
is dimensioned to process approximately regulator only allows the maximal rainwater EuroHEK 6001500 sand and sludge traps and sludge traps. For smaller sand and
95% of the annual downpour. amount corresponding to the dimensioned are designed for stormwater treatment in sludge traps the SandSET-1000 is available
flow into the separator system. The excess parking areas, petrol station filling areas and as an accessory.
flow is shortly dammed, until let flow via
bypass pipe past the separator system. Traps in yard areas.

The rainwater from surfaced areas carries


sand and finer-grained sludge. Most of the
heavy metals occurring in traffic areas are
bound to these solid particles.

Flow rate

Concentration of
oil and solids
Also during the peak flow of the heavy
downpour the separator system functions
Time normally. The Labko FRW Flow Regulation
Well leads the excess flow exceeding the
First Flush phenomenon: Most of the oils and heavy metals carried by the rainwater are dimensioned flow of the oil separator via the
flushed from surfaced areas during the first phase of the downpour. At this point, the bypass pipe to pass the separator system.
rainwater flow has not reached its maximum yet, allowing all the rainwater flow though Thus the washout of the separators is
the separators of the Labko Bypass System. prevented.

SandSET-1000 SET-2000
sludge alarm oil alarm

Labko FRW
Flow Regulation EuroHEK Omega EuroPEK EuroNOK FRW
Well sand and sludge Omega Filter sampling shaft with
separator oil separator a shut-off valve

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
6 +358 20 1285 200 -358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 7
Labko Oil Separator Systems Labko Oil Separator Systems

EuroPEK oil separator EuroPEK Omega Filter oil separator


EuroPEK EuroPEK
The coalescing plates of the EuroPEK solids in the rainwater, meaning e.g. waste
separators can be cleaned with pressure treatment plants or collecting sites, scrap
washer, after which they reach their proper yards, service and storage sites for earth-

Oil Separator functioning again. The possibility to clean


the plates significantly reduces the main-
movers, and areas with peat processing.
Omega

EuroPEK oil separator is a class I oil


separator. It is designed and tested
tenance and service costs of the separator,
for there are no filters, which are classified
as hazardous waste, to be disposed of.
EuroPEK oil separators include the OilSET-
1000 oil alarm with ATEX compliance as
a standard. It indicates an alarm if the oil
Filter
according to the requirements of the
EN 858 standard, and it can be used to
treat all kinds of oily waste and rainwaters.
EuroPEK separators present an extensive
storage space is full. Further information
on the alarm device and data transfer can Oil Separator
range of applicability. They are best applied be found on page 12.
EuroPEK Omega Filter oil separators are class
in areas, in which there is a high content of
EuroPEK oil separators are equipped with I separators. They are designed and tested
coalescing plates, which separate oil from in accordance with the EN 858 standard,
the water. The process is based on the fact and they are suitable for treating oily rainwater.
that oil drops coalesce when they run onto EuroPEK Omega Filter separators are
the oleophilic (oil attracting) plates. When available in size classes NS3-NS15. Their
the size of the oil drop grows, its upward high cleaning capacity is based on a
velocity grows (Stokes' law) and the oil coalescent 3-D filter.
drops rise along the angled plates surfaces
and through the holes in the coalescing The EuroPEK Omega Filter oil separators are
plates. The separated oil is stored as a made of strong and recyclable PE-plastic.
homogenous layer on the surface of the The separators are light to transport and easy
water in the separator. to install. The spherical bottom of the sludge
storage space allows complete emptying.

EuroPEK Omega Filter includes the SET-2000


oil alarm with ATEX compliance as a standard. The superb cleaning
It indicates an alarm if the oil storage space efficiency of the EuroPEK
Omega Filter oil separators
is full or in case of a high water level. Further
is verified by flow tests run
information on the alarm device and data in compliance with the
transfer can be found on page 12. EN 858 standard.

Operating
principle of the SandSET-1000 OilSET-1000
coalescer. sludge alarm oil alarm

Labko FRW
Flow Regulation EuroHEK sand EuroPEK EuroNOK FRW
Well and sludge trap oil separator sampling shaft with
a shut-off valve

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
8 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 9
Labko Oil Separator Systems Labko Oil Separator Systems

EuroPEK oil separator EuroPEK Omega Filter oil separator


EuroPEK EuroPEK
The coalescing plates of the EuroPEK solids in the rainwater, meaning e.g. waste
separators can be cleaned with pressure treatment plants or collecting sites, scrap
washer, after which they reach their proper yards, service and storage sites for earth-

Oil Separator functioning again. The possibility to clean


the plates significantly reduces the main-
movers, and areas with peat processing.
Omega

EuroPEK oil separator is a class I oil


separator. It is designed and tested
tenance and service costs of the separator,
for there are no filters, which are classified
as hazardous waste, to be disposed of.
EuroPEK oil separators include the OilSET-
1000 oil alarm with ATEX compliance as
a standard. It indicates an alarm if the oil
Filter
according to the requirements of the
EN 858 standard, and it can be used to
treat all kinds of oily waste and rainwaters.
EuroPEK separators present an extensive
storage space is full. Further information
on the alarm device and data transfer can Oil Separator
range of applicability. They are best applied be found on page 12.
EuroPEK Omega Filter oil separators are class
in areas, in which there is a high content of
EuroPEK oil separators are equipped with I separators. They are designed and tested
coalescing plates, which separate oil from in accordance with the EN 858 standard,
the water. The process is based on the fact and they are suitable for treating oily rainwater.
that oil drops coalesce when they run onto EuroPEK Omega Filter separators are
the oleophilic (oil attracting) plates. When available in size classes NS3-NS15. Their
the size of the oil drop grows, its upward high cleaning capacity is based on a
velocity grows (Stokes' law) and the oil coalescent 3-D filter.
drops rise along the angled plates surfaces
and through the holes in the coalescing The EuroPEK Omega Filter oil separators are
plates. The separated oil is stored as a made of strong and recyclable PE-plastic.
homogenous layer on the surface of the The separators are light to transport and easy
water in the separator. to install. The spherical bottom of the sludge
storage space allows complete emptying.

EuroPEK Omega Filter includes the SET-2000


oil alarm with ATEX compliance as a standard. The superb cleaning
It indicates an alarm if the oil storage space efficiency of the EuroPEK
Omega Filter oil separators
is full or in case of a high water level. Further
is verified by flow tests run
information on the alarm device and data in compliance with the
transfer can be found on page 12. EN 858 standard.

Operating
principle of the SandSET-1000 OilSET-1000
coalescer. sludge alarm oil alarm

Labko FRW
Flow Regulation EuroHEK sand EuroPEK EuroNOK FRW
Well and sludge trap oil separator sampling shaft with
a shut-off valve

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
8 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 9
Labko Oil Separator Systems Labko Oil Separator Systems

EuroPEK Filter oil separator EuroNOK FRW sampling shaft with a shut-off valve EuroHUK maintenance shaft PP-HUK 600 maintenance shaft


EuroPEK EuroPEK Filter is a class I oil separator.
It is designed and tested according to the
requirements of the EN 858 standard. The
EuroPEK Filter separators are designed for
areas with only a low quantity of solids and
oils in the rainwater.
EuroNOK EuroHUK and
Filter Oil cleaning capacity of the EuroPEK Filter is
based on a coalescent 3-D filter. There are
As a standard, an ATEX-approved SET-
2000 oil alarm is included in the EuroPEK
FRW PP-HUK 600
Separator 1-4 filters in each separator, depending on
the model. EuroPEK Filter separators are
made of reinforced plastic and they are
Filter oil separator. The oil alarm signals,
not only when emptying is needed, but in
Sampling Maintenance
available in size classes NS20-NS150.
case of blocking, too. Further information
on the alarm device and data transfer can
be found on page 12.
Shaft with Shaft
a shut-off The EuroHUK maintenance shaft is a water-
proof solution in compliance with the oil
EuroNOK FRW sampling shaft with a
shut-off valve.

valve separator standard to go with the separators.


The EuroHUK maintenance shaft is selected
according to the installation depth of the
According to the EN 858 standard, a separator.
sampling shaft always builds a part of the
Since the maintenance shaft is light in its
oil separator system. The EuroNOK
weight, the installation goes fast. Except for
sampling shafts make it possible to monitor
the smallest model, all the shafts have steps
the quality of the wastewater or rainwater
inside to ease the maintenance. A special-
that is led into the sewer system.
shaped gasket, which is delivered with the
In a direct system the EuroNOK sampling maintenance shaft, guarantees that the sep-
shaft is installed to follow the oil separator. arator and the shaft are compatible and that
In the Labko Bypass System, the EuroNOK their junction is tight.
FRW is used. The difference in the EuroHUK maintenance shafts installed.
PP-HUK 600 maintenance shafts are used
EuroNOK FRW is that the bypass-pipe is
with EuroPEK Filter oil separators to ease the
connected back to the rainwater sewer. A special-shaped
maintenance of their filters. PP-HUK 600 is
Both the EuroNOK and the EuroNOK FRW gasket guarantees
a waterproof solution in compliance with the the standard-
The superb cleaning efficiency of the contain a shut-off valve that makes it
oil separator standard to go with the separa- compliant
EuroPEK Filter oil separators is verified possible to close the sewer line, should an
by flow tests run in compliance with the tors. tightness
accident occur in the area. of the main-
EN 858 standard.
Cast iron covers and frames are available as tenance
SET-2000 accessories for the maintenance shafts. They shaft.
oil alarm are chosen according to the traffic load on
SandSET-1000
sludge alarm the site.

Labko FRW
Flow Regulation EuroHEK sand PP-HUK 600 EuroPEK Filter EuroHUK EuroNOK FRW
Well and sludge trap maintenance oil separator maintenance sampling shaft with
shaft shaft a shut-off valve

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
10 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 11
Labko Oil Separator Systems Labko Oil Separator Systems

EuroPEK Filter oil separator EuroNOK FRW sampling shaft with a shut-off valve EuroHUK maintenance shaft PP-HUK 600 maintenance shaft


EuroPEK EuroPEK Filter is a class I oil separator.
It is designed and tested according to the
requirements of the EN 858 standard. The
EuroPEK Filter separators are designed for
areas with only a low quantity of solids and
oils in the rainwater.
EuroNOK EuroHUK and
Filter Oil cleaning capacity of the EuroPEK Filter is
based on a coalescent 3-D filter. There are
As a standard, an ATEX-approved SET-
2000 oil alarm is included in the EuroPEK
FRW PP-HUK 600
Separator 1-4 filters in each separator, depending on
the model. EuroPEK Filter separators are
made of reinforced plastic and they are
Filter oil separator. The oil alarm signals,
not only when emptying is needed, but in
Sampling Maintenance
available in size classes NS20-NS150.
case of blocking, too. Further information
on the alarm device and data transfer can
be found on page 12.
Shaft with Shaft
a shut-off The EuroHUK maintenance shaft is a water-
proof solution in compliance with the oil
EuroNOK FRW sampling shaft with a
shut-off valve.

valve separator standard to go with the separators.


The EuroHUK maintenance shaft is selected
according to the installation depth of the
According to the EN 858 standard, a separator.
sampling shaft always builds a part of the
Since the maintenance shaft is light in its
oil separator system. The EuroNOK
weight, the installation goes fast. Except for
sampling shafts make it possible to monitor
the smallest model, all the shafts have steps
the quality of the wastewater or rainwater
inside to ease the maintenance. A special-
that is led into the sewer system.
shaped gasket, which is delivered with the
In a direct system the EuroNOK sampling maintenance shaft, guarantees that the sep-
shaft is installed to follow the oil separator. arator and the shaft are compatible and that
In the Labko Bypass System, the EuroNOK their junction is tight.
FRW is used. The difference in the EuroHUK maintenance shafts installed.
PP-HUK 600 maintenance shafts are used
EuroNOK FRW is that the bypass-pipe is
with EuroPEK Filter oil separators to ease the
connected back to the rainwater sewer. A special-shaped
maintenance of their filters. PP-HUK 600 is
Both the EuroNOK and the EuroNOK FRW gasket guarantees
a waterproof solution in compliance with the the standard-
The superb cleaning efficiency of the contain a shut-off valve that makes it
oil separator standard to go with the separa- compliant
EuroPEK Filter oil separators is verified possible to close the sewer line, should an
by flow tests run in compliance with the tors. tightness
accident occur in the area. of the main-
EN 858 standard.
Cast iron covers and frames are available as tenance
SET-2000 accessories for the maintenance shafts. They shaft.
oil alarm are chosen according to the traffic load on
SandSET-1000
sludge alarm the site.

Labko FRW
Flow Regulation EuroHEK sand PP-HUK 600 EuroPEK Filter EuroHUK EuroNOK FRW
Well and sludge trap maintenance oil separator maintenance sampling shaft with
shaft shaft a shut-off valve

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
10 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 11
Labko Oil Separator Systems Labko Oil Separator Systems

Alarm devices Data transfer LabkoNet Labko FRW Flow Regulation Wells EuroHEK sand and sludge traps

Legend
A = area of the yard (0.015 l/(s*m2)) L = length
Du = outer diameter h = installation depth
Du1/Du2 = inner diameter V = effective volume

Alarm devices and Data transfer


Dy
Dy1/Dy2
H1/H2/H3/H4
= outer diameter of the ventilation pipe (accessory)
= outer diameter of the connection pipe
= height
Vo
Vs
Lkm
= oil storage volume
= sludge storage volume
= number of the coalescent 3-D filters

remote monitoring and LabkoNet Labko FRW Flow Regulation Wells Labko
FRW
Nominal Total flow
flow into the of the
A Du Du1 Dy Dy1 Dy2 H1 H2 H3 H4 h* Weight

Nominal size separator system


Alarm systems monitoring Labcom 200 communication unit transfers 10/30...100/300 l/s l/s m2 mm mm mm mm mm mm mm mm mm kg
the functioning of the separators the alarm directly to the recipient FRW 10/30 10 30 2000 1780 800 110 200 160 750 700 900 1660 187
FRW 15/45 15 45 3000 1780 800 110 250 200 750 700 900 1660 188
All the separators of Wavin-Labko can be equipped with alarm Labcom 200 sends alarms and measurement data as GSM short
FRW 20/60 20 60 4000 1780 800 110 250 200 750 700 900 1660 191
units that control the functioning of the separator. Most separators messages either directly to the user's own mobile phone or via FRW 30/90 30 90 6000 1780 800 110 315 250 750 700 940 1660 211
include the alarm devices as a standard. The alarm can be LabkoNet system. The LabkoNet system makes sure the information FRW 40/120 40 120 8000 1780 800 110 315 315 650 600 850 1660 225
transmitted directly to the user's house automation system or with is delivered to the user, for the server also controls the functioning FRW 50/150 50 150 10000 1780 800 110 400 315 650 600 810 1660 232
FRW 65/195 65 195 13000 2170 800 110 400 315 950 900 1090 2100 321
the Labcom communication unit to a GSM phone. Furthermore, of the communication unit. FRW 80/240 80 240 16000 2170 800 110 500 315 950 900 1150 2100 391
the alarm can be transmitted via LabkoNet server to those who FRW 100/300 100 300 20000 2250 800 110 500 315 950 900 1150 2200 407
LabkoNet system is an easy and reliable way Nominal size
find the information is essential. When the separators are remotely FRW 125/375 125 375 25000 2200 800 110 500 400 475 500 475 1785
of transferring and controlling the alarm data 125/375...150/450
FRW 150/450 150 450 30000 2200 800 110 *** 400 475 500 475 1785
monitored, timely emptying is made possible, and thus the Introducing and using the LabkoNet system is easy; no separate *** according to the delivery Dy1 500 or Dy1 600.
environmental risks are minimized and costs are lowered. software is needed. Only an Internet connection, Labcom 200 EuroHUK 800 FRW 10/30 - 50/150 FRW 65/195 - 100/300 FRW 125/375 - 150/450
for FRW h* (mm) h* (mm) h* (mm)
communication unit, gauges and alarm devices are needed. In
9-13 1300-1700 1700-2100 2100-2500
addition to the separator alarms, e.g. storage tank level gauging 13-17 1700-2100 2100-2500 2500-2900
can be connected with the LabkoNet. 17-21 2100-2500 2500-2900 2900-3400
21-25 2500-2900 2900-3400 3400-3900

For further information on LabkoNet and its possibilities,


visit www.labkonet.com
EuroHEK 600...1500 sand and EuroHEK Du Du1 Dy Dy1 H1 H2 H3 h V Weight
SandSET-1000 sludge alarm device sludge traps mm mm mm mm mm mm mm mm l kg
Indicates an alarm when the sludge storage space is full. GSM short messages 600 h 9-13 1000 600 110 110...250 870 850 2070 900...1300 600 91
The timely desludging reduces unnecessary emptying and The alarm can be transmitted to the h 13-17 2470 1300...1700 106
guarantees the smooth operation of the oil separator. user's GSM either directly with h 17-21 2870 1700...2100 122
Labcom 200 communication unit or h 21-25 3270 2100...2500 137
via LabkoNet server. 1000 h 9-13 1400 600 110 110...250 870 850 2070 900...1300 1000 151
h 13-17 2470 1300...1700 175
h 17-21 2870 1700...2100 199
h 21-25 3270 2100...2500 223
1500 h 9-13 1400 600 110 110...250 1410 1340 2610 900...1300 1500 183
h 13-17 3010 1300...1700 207
h 17-21 3410 1700...2100 231
h 21-25 3810 2100...2500 255
SandSET-1000 sludge alarm as an accessory.

OilSET-1000 oil alarm


Indicates an alarm if the oil storage EuroHEK Omega sand and EuroHEK Omega Du Du1 Dy Dy1 H1 H2 H3 h* V Weight
space is full and it is time for sludge traps mm mm mm mm mm mm mm l kg
emptying. This prevents leakages 2000 1750 600 110 110...200 1280 1200 1650 2000 170
E-mail
into the sewer system. 4000 2170 600 110 110...200 1730 1650 2100 4000 230
LabkoNet can also send Dy 5000 2200 600 110 110...200 1820 1730 2250 5000 280
the alarm as an e-mail
* For further information on EuroHUK 600: table on page 15.
message. SandSET-1000 sludge alarm as an accessory.
Labcom 200 LabkoNet server
communication unit Collects the alarms and adapts
A data transfer unit their information to be sent further Look
designed for transmitting either as a short message or as at live
demo
measurement and an e-mail. The data is displayed
alarm data. on user's own web page, too. EuroHEK Du1 Du2 Dy Dy1 H1 H2 H3 L h* V Weight
EuroHEK 6500...8000 sand and
SET-2000 sludge traps mm mm mm mm mm mm mm mm l kg
oil alarm 6500 600 1600 110 110...400 1410 1360 1860 4000 6500 396
8000 600 1600 110 110...400 1410 1360 1860 4900 8000 513
Gives an alarm if LabkoNet service www.labkonet.com
* For further information on PP-HUK 600: table on page 15.
the oil storage space LabkoNet server collects and logs data in the Internet and it is SandSET-1000 sludge alarm as an accessory.
is full or if the water applicable with different user names and passwords to meet
surface level rises different needs. Among other things, the service provides reports
indicating the need as printouts.
for filter maintenance.
L

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
12 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 13
Labko Oil Separator Systems Labko Oil Separator Systems

Alarm devices Data transfer LabkoNet Labko FRW Flow Regulation Wells EuroHEK sand and sludge traps

Legend
A = area of the yard (0.015 l/(s*m2)) L = length
Du = outer diameter h = installation depth
Du1/Du2 = inner diameter V = effective volume

Alarm devices and Data transfer


Dy
Dy1/Dy2
H1/H2/H3/H4
= outer diameter of the ventilation pipe (accessory)
= outer diameter of the connection pipe
= height
Vo
Vs
Lkm
= oil storage volume
= sludge storage volume
= number of the coalescent 3-D filters

remote monitoring and LabkoNet Labko FRW Flow Regulation Wells Labko
FRW
Nominal Total flow
flow into the of the
A Du Du1 Dy Dy1 Dy2 H1 H2 H3 H4 h* Weight

Nominal size separator system


Alarm systems monitoring Labcom 200 communication unit transfers 10/30...100/300 l/s l/s m2 mm mm mm mm mm mm mm mm mm kg
the functioning of the separators the alarm directly to the recipient FRW 10/30 10 30 2000 1780 800 110 200 160 750 700 900 1660 187
FRW 15/45 15 45 3000 1780 800 110 250 200 750 700 900 1660 188
All the separators of Wavin-Labko can be equipped with alarm Labcom 200 sends alarms and measurement data as GSM short
FRW 20/60 20 60 4000 1780 800 110 250 200 750 700 900 1660 191
units that control the functioning of the separator. Most separators messages either directly to the user's own mobile phone or via FRW 30/90 30 90 6000 1780 800 110 315 250 750 700 940 1660 211
include the alarm devices as a standard. The alarm can be LabkoNet system. The LabkoNet system makes sure the information FRW 40/120 40 120 8000 1780 800 110 315 315 650 600 850 1660 225
transmitted directly to the user's house automation system or with is delivered to the user, for the server also controls the functioning FRW 50/150 50 150 10000 1780 800 110 400 315 650 600 810 1660 232
FRW 65/195 65 195 13000 2170 800 110 400 315 950 900 1090 2100 321
the Labcom communication unit to a GSM phone. Furthermore, of the communication unit. FRW 80/240 80 240 16000 2170 800 110 500 315 950 900 1150 2100 391
the alarm can be transmitted via LabkoNet server to those who FRW 100/300 100 300 20000 2250 800 110 500 315 950 900 1150 2200 407
LabkoNet system is an easy and reliable way Nominal size
find the information is essential. When the separators are remotely FRW 125/375 125 375 25000 2200 800 110 500 400 475 500 475 1785
of transferring and controlling the alarm data 125/375...150/450
FRW 150/450 150 450 30000 2200 800 110 *** 400 475 500 475 1785
monitored, timely emptying is made possible, and thus the Introducing and using the LabkoNet system is easy; no separate * For further information on EuroHUK 800: table below. *** According to the delivery Dy1 500 or Dy1 600.
environmental risks are minimized and costs are lowered. software is needed. Only an Internet connection, Labcom 200 EuroHUK 800 FRW 10/30 - 50/150 FRW 65/195 - 100/300 FRW 125/375 - 150/450
for FRW h (mm) h (mm) h (mm)
communication unit, gauges and alarm devices are needed. In
9-13 1300-1700 1700-2100 2100-2500
addition to the separator alarms, e.g. storage tank level gauging 13-17 1700-2100 2100-2500 2500-2900
can be connected with the LabkoNet. 17-21 2100-2500 2500-2900 2900-3400
21-25 2500-2900 2900-3400 3400-3900

For further information on LabkoNet and its possibilities,


visit www.labkonet.com
EuroHEK 600...1500 sand and EuroHEK Du Du1 Dy Dy1 H1 H2 H3 h V Weight
SandSET-1000 sludge alarm device sludge traps mm mm mm mm mm mm mm mm l kg
Indicates an alarm when the sludge storage space is full. GSM short messages 600 h 9-13 1000 600 110 110...250 870 850 2070 900...1300 600 91
The timely desludging reduces unnecessary emptying and The alarm can be transmitted to the h 13-17 2470 1300...1700 106
guarantees the smooth operation of the oil separator. user's GSM either directly with h 17-21 2870 1700...2100 122
Labcom 200 communication unit or h 21-25 3270 2100...2500 137
via LabkoNet server. 1000 h 9-13 1400 600 110 110...250 870 850 2070 900...1300 1000 151
h 13-17 2470 1300...1700 175
h 17-21 2870 1700...2100 199
h 21-25 3270 2100...2500 223
1500 h 9-13 1400 600 110 110...250 1410 1340 2610 900...1300 1500 183
h 13-17 3010 1300...1700 207
h 17-21 3410 1700...2100 231
h 21-25 3810 2100...2500 255
SandSET-1000 sludge alarm as an accessory.

OilSET-1000 oil alarm


Indicates an alarm if the oil storage EuroHEK Omega sand and EuroHEK Omega Du Du1 Dy Dy1 H1 H2 H3 h* V Weight
space is full and it is time for sludge traps mm mm mm mm mm mm mm l kg
emptying. This prevents leakages 2000 1750 600 110 110...200 1280 1200 1650 2000 170
E-mail
into the sewer system. 4000 2170 600 110 110...200 1730 1650 2100 4000 230
LabkoNet can also send Dy 5000 2200 600 110 110...200 1820 1730 2250 5000 280
the alarm as an e-mail
* For further information on EuroHUK 600: table on page 15.
message. SandSET-1000 sludge alarm as an accessory.
Labcom 200 LabkoNet server
communication unit Collects the alarms and adapts
A data transfer unit their information to be sent further Look
designed for transmitting either as a short message or as at live
demo
measurement and an e-mail. The data is displayed
alarm data. on user's own web page, too. EuroHEK Du1 Du2 Dy Dy1 H1 H2 H3 L h* V Weight
EuroHEK 6500...8000 sand and
SET-2000 sludge traps mm mm mm mm mm mm mm mm l kg
oil alarm 6500 600 1600 110 110...400 1410 1360 1860 4000 6500 396
8000 600 1600 110 110...400 1410 1360 1860 4900 8000 513
Gives an alarm if LabkoNet service www.labkonet.com
* For further information on PP-HUK 600: table on page 15.
the oil storage space LabkoNet server collects and logs data in the Internet and it is SandSET-1000 sludge alarm as an accessory.
is full or if the water applicable with different user names and passwords to meet
surface level rises different needs. Among other things, the service provides reports
indicating the need as printouts.
for filter maintenance.
L

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
12 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 13
Labko Oil Separator Systems Labko Oil Separator Systems

EuroHEK sand and sludge traps EuroPEK oil separators EuroNOK FRW sampling shafts with a shut-off valve EuroHUK maintenance shafts PP-HUK 600 maintenance shafts

EuroHEK 10000...50000 sand and EuroHEK Du1 Du2 Dy Dy1 H1 H2 H3 L h* V Weight EuroNOK FRW sampling shafts EuroNOK FRW Du Du1 Dy Dy1 Dy2 H1 H2 H3 H4 h* Weight
sludge traps mm mm mm mm mm mm mm mm l kg with a shut-off valve mm mm 110 mm mm mm mm mm mm kg
10000 600 1600 110 110...400 1410 1360 1950 6100 10000 620 10/30 1300 600 110 200 160 440 410 950 540
13000 600 2200 110 110...400 1930 1880 2550 4400 13000 703 15/45 1300 600 110 250 200 440 410 950 540
15000 600 2200 110 110...400 1930 1880 2550 4900 15000 774 Nominal size 20/60 1300 600 110 250 200 440 410 950 540
Dy
16000 600 2200 110 110...400 1930 1880 2550 5200 16000 817 10/30...100/300 30/90 1300 600 110 315 250 440 410 950 540
20000 600 2200 110 110...400 1930 1880 2550 6400 20000 997 40/120** 1400 600 110 315 315 440 410 1390 540
30000 600 3000 110 110...400 2650 2600 3360 5400 30000 2000 50/150** 1400 600 110 400 315 440 410 1390 540
40000 600 3000 110 110...400 2650 2600 3360 7000 40000 2340 65/195** 1400 600 110 400 315 440 410 1390 540
50000 600 3000 110 110...400 2650 2600 3360 8500 50000 80/240** 1400 800 110 500 315 440 410 1390 540
* For further information on EuroHUK 600: table on page 15. 100/300** 1400 800 110 500 315 440 410 1390 540
SandSET-1000 sludge alarm as a standard. 125/375** 1400 800 110 500 400 440 410 1390 540
L
150/450** 1400 800 110 *** 400 440 410 1390 540
* For further information on EuroHUK 600 and EuroHUK 800: table on page 15.
** minimum installation depth h=1300 mm.
EuroPEK oil separators EuroPEK Maximum Du1 Du2 Dy Dy1 H1 H2 H3 L h* V Vo Weight *** according to the delivery Dy1 500 or Dy1 600.
flow Nominal size
l/s mm mm mm mm mm mm mm mm l l kg 125/375...150/450
NS3 3 800 1000 110 110 860 790 1380 1950 860 250 180
NS6 6 800 1000 110 160 860 790 1380 2200 1000 290 235
NS10 10 800/600 1000 110 160 860 790 1380 4100 1950 550 355
NS15 15 800 1400 110 200 1300 1230 1750 2800 2940 610 450
NS20 20 800 1600 110 200 1410 1340 1950 3000 3930 770 600
NS30 30 800/600 1600 110 250 1410 1340 1950 4000 5500 900 810
NS40 40 800 2200 110 315 1940 1870 2550 3600 10000 1000 1100
NS50 50 800/600 2200 110 315 1940 1870 2550 4600 13500 1500 1705
NS65 65 800/600 3000 110 315 2740 2670 3360 5500 32200 1500 2500
NS80 80 800/600 3000 110 315 2740 2670 3360 7300 41000 2000 2900
EuroNOK sampling shafts
NS100 100 800/600 3000 110 315 2740 2670 3360 7500 42000 2000 EuroNOK Du Du1 Dy Dy1 H1 H2 H3 h* Weight
with a shut-off valve
NS125 125 800/600 3000 110 400 2740 2670 3360 8800 52500 2200 mm mm mm mm mm mm mm kg
NS150 150 800/600 3000 110 400 2740 2670 3360 10000 DN110 1300 600 110 110 440 410 950 80
* For further information on EuroHUK 600 and EuroHUK 800: table on page 15. DN160 1300 600 110 160 440 410 950 84
OilSET-1000 oil alarm as a standard. DN200 1300 600 110 200 440 410 950 101
DN250 1300 600 110 250 440 410 950 124
DN315 1300 600 110 315 440 410 950 155
DN400** 1560 600 110 400 440 410 1310
* For further information on EuroHUK 600: table on page 15.
EuroPEK Omega Filter EuroPEK Maximum Du Du1 Dy Dy1 H1 H2 H3 h* V Vo Vs Weight ** minimum installation depth h=1300 mm.
oil separators Omega Filter flow
l/s mm mm mm mm mm mm mm l l l kg
NS3/L 3 1780 600 110 110 1300 1220 1650 2100 280 950 170
NS6/S 6 1780 600 110 160 1300 1220 1650 2100 280 650 170
Dy NS10 10 1780 600 110 160 1300 1220 1650 2100 280 separate 170
NS15 15 2170 600 110 200 1730 1650 2100 4200 380 separate 240 EuroHUK 600 and 800 EuroHUK 600 Du1 Du2 h Weight
* For further information on EuroHUK 600: table on page 15. maintenance shafts mm mm mm kg
SET-2000 oil alarm as a standard. 9-13 600 1000 900...1300 22
13-17 600 1000 1300...1700 38
17-21 600 1000 1700...2100 56
21-25 600 1000 2100...2500 80
A suitable cover and frame set is the floating cover and frame set 600.

EuroHUK 800 Du1 Du2 h Weight


mm mm mm kg
9-13 800 1000 900...1300 25
EuroPEK Filter oil separators EuroPEK Maximum Du1 Du2 Dy Dy1 H1 H2 H3 L h* V Vo Lkm Weight 13-17 800 1000 1300...1700 42
Filter flow 17-21 800 1000 1700...2100 60
l/s mm mm mm mm mm mm mm mm l l pcs kg 21-25 800 1000 2100...2500 84
NS20 20 600 1600 110 250 1410 1340 1950 3800 6000 640 1 500 A suitable cover and frame set is the floating cover and frame set 800.
NS30 30 600 1600 110 250 1410 1340 1950 3800 6000 640 2 550
NS40 40 600 1600 110 315 1410 1340 1950 3800 6000 640 2 560
NS50 50 600 1600 110 315 1360 1290 1950 5300 8700 1000 3 750 PP-HUK 600 maintenance shafts PP-HUK 600 Du Du1 L h* Weight
NS65 65 600 2200 110 315 1940 1870 2550 4100 13000 900 3 1350 mm mm mm mm kg
NS80 80 600 2200 110 315 1940 1870 2550 5900 19200 1400 4 1750 9-13 670 602 1000 900...1300 16
NS100 100 600 2200 110 400 1940 1870 2550 8700 28000 2100 4 2400 13-17 670 602 1400 1300...1700 20
NS125 125 600 2200 110 400 1940 1870 2550 11400 37100 3070 4 3000 17-21 670 602 1800 1700...2100 25
NS150 150 600 2200 110 400 1940 1870 2550 13000 42500 3520 4 3450 L 21-25 670 602 2200 2100...2500 31
* For further information on EuroHUK 600 and PP-HUK 600: table on page 15. * connection depth of the separator from the ground surface to the water flow of the inlet.
L
SET-2000 oil alarm as a standard. A suitable cover and frame set is the floating cover and frame set 600.

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
14 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 15
Labko Oil Separator Systems Labko Oil Separator Systems

EuroHEK sand and sludge traps EuroPEK oil separators EuroNOK FRW sampling shafts with a shut-off valve EuroHUK maintenance shafts PP-HUK 600 maintenance shafts

EuroHEK 10000...50000 sand and EuroHEK Du1 Du2 Dy Dy1 H1 H2 H3 L h* V Weight EuroNOK FRW sampling shafts EuroNOK FRW Du Du1 Dy Dy1 Dy2 H1 H2 H3 H4 h* Weight
sludge traps mm mm mm mm mm mm mm mm l kg with a shut-off valve mm mm 110 mm mm mm mm mm mm kg
10000 600 1600 110 110...400 1410 1360 1950 6100 10000 620 10/30 1300 600 110 200 160 440 410 950 540
13000 600 2200 110 110...400 1930 1880 2550 4400 13000 703 15/45 1300 600 110 250 200 440 410 950 540
15000 600 2200 110 110...400 1930 1880 2550 4900 15000 774 Nominal size 20/60 1300 600 110 250 200 440 410 950 540
Dy
16000 600 2200 110 110...400 1930 1880 2550 5200 16000 817 10/30...100/300 30/90 1300 600 110 315 250 440 410 950 540
20000 600 2200 110 110...400 1930 1880 2550 6400 20000 997 40/120** 1400 600 110 315 315 440 410 1390 540
30000 600 3000 110 110...400 2650 2600 3360 5400 30000 2000 50/150** 1400 600 110 400 315 440 410 1390 540
40000 600 3000 110 110...400 2650 2600 3360 7000 40000 2340 65/195** 1400 600 110 400 315 440 410 1390 540
50000 600 3000 110 110...400 2650 2600 3360 8500 50000 80/240** 1400 800 110 500 315 440 410 1390 540
* For further information on EuroHUK 600: table on page 15. 100/300** 1400 800 110 500 315 440 410 1390 540
SandSET-1000 sludge alarm as a standard. 125/375** 1400 800 110 500 400 440 410 1390 540
L
150/450** 1400 800 110 *** 400 440 410 1390 540
* For further information on EuroHUK 600 and EuroHUK 800: table on page 15.
** minimum installation depth h=1300 mm.
EuroPEK oil separators EuroPEK Maximum Du1 Du2 Dy Dy1 H1 H2 H3 L h* V Vo Weight *** according to the delivery Dy1 500 or Dy1 600.
flow Nominal size
l/s mm mm mm mm mm mm mm mm l l kg 125/375...150/450
NS3 3 800 1000 110 110 860 790 1380 1950 860 250 180
NS6 6 800 1000 110 160 860 790 1380 2200 1000 290 235
NS10 10 800/600 1000 110 160 860 790 1380 4100 1950 550 355
NS15 15 800 1400 110 200 1300 1230 1750 2800 2940 610 450
NS20 20 800 1600 110 200 1410 1340 1950 3000 3930 770 600
NS30 30 800/600 1600 110 250 1410 1340 1950 4000 5500 900 810
NS40 40 800 2200 110 315 1940 1870 2550 3600 10000 1000 1100
NS50 50 800/600 2200 110 315 1940 1870 2550 4600 13500 1500 1705
NS65 65 800/600 3000 110 315 2740 2670 3360 5500 32200 1500 2500
NS80 80 800/600 3000 110 315 2740 2670 3360 7300 41000 2000 2900
EuroNOK sampling shafts
NS100 100 800/600 3000 110 315 2740 2670 3360 7500 42000 2000 EuroNOK Du Du1 Dy Dy1 H1 H2 H3 h* Weight
with a shut-off valve
NS125 125 800/600 3000 110 400 2740 2670 3360 8800 52500 2200 mm mm mm mm mm mm mm kg
NS150 150 800/600 3000 110 400 2740 2670 3360 10000 DN110 1300 600 110 110 440 410 950 80
* For further information on EuroHUK 600 and EuroHUK 800: table on page 15. DN160 1300 600 110 160 440 410 950 84
OilSET-1000 oil alarm as a standard. DN200 1300 600 110 200 440 410 950 101
DN250 1300 600 110 250 440 410 950 124
DN315 1300 600 110 315 440 410 950 155
DN400** 1560 600 110 400 440 410 1310
* For further information on EuroHUK 600: table on page 15.
EuroPEK Omega Filter EuroPEK Maximum Du Du1 Dy Dy1 H1 H2 H3 h* V Vo Vs Weight ** minimum installation depth h=1300 mm.
oil separators Omega Filter flow
l/s mm mm mm mm mm mm mm l l l kg
NS3/L 3 1780 600 110 110 1300 1220 1650 2100 280 950 170
NS6/S 6 1780 600 110 160 1300 1220 1650 2100 280 650 170
Dy NS10 10 1780 600 110 160 1300 1220 1650 2100 280 separate 170
NS15 15 2170 600 110 200 1730 1650 2100 4200 380 separate 240 EuroHUK 600 and 800 EuroHUK 600 Du1 Du2 h Weight
* For further information on EuroHUK 600: table on page 15. maintenance shafts mm mm mm kg
SET-2000 oil alarm as a standard. 9-13 600 1000 900...1300 22
13-17 600 1000 1300...1700 38
17-21 600 1000 1700...2100 56
21-25 600 1000 2100...2500 80
A suitable cover and frame set is the floating cover and frame set 600.

EuroHUK 800 Du1 Du2 h Weight


mm mm mm kg
9-13 800 1000 900...1300 25
EuroPEK Filter oil separators EuroPEK Maximum Du1 Du2 Dy Dy1 H1 H2 H3 L h* V Vo Lkm Weight 13-17 800 1000 1300...1700 42
Filter flow 17-21 800 1000 1700...2100 60
l/s mm mm mm mm mm mm mm mm l l pcs kg 21-25 800 1000 2100...2500 84
NS20 20 600 1600 110 250 1410 1340 1950 3800 6000 640 1 500 A suitable cover and frame set is the floating cover and frame set 800.
NS30 30 600 1600 110 250 1410 1340 1950 3800 6000 640 2 550
NS40 40 600 1600 110 315 1410 1340 1950 3800 6000 640 2 560
NS50 50 600 1600 110 315 1360 1290 1950 5300 8700 1000 3 750 PP-HUK 600 maintenance shafts PP-HUK 600 Du Du1 L h* Weight
NS65 65 600 2200 110 315 1940 1870 2550 4100 13000 900 3 1350 mm mm mm mm kg
NS80 80 600 2200 110 315 1940 1870 2550 5900 19200 1400 4 1750 9-13 670 602 1000 900...1300 16
NS100 100 600 2200 110 400 1940 1870 2550 8700 28000 2100 4 2400 13-17 670 602 1400 1300...1700 20
NS125 125 600 2200 110 400 1940 1870 2550 11400 37100 3070 4 3000 17-21 670 602 1800 1700...2100 25
NS150 150 600 2200 110 400 1940 1870 2550 13000 42500 3520 4 3450 L 21-25 670 602 2200 2100...2500 31
* For further information on EuroHUK 600 and PP-HUK 600: table on page 15. * connection depth of the separator from the ground surface to the water flow of the inlet.
L
SET-2000 oil alarm as a standard. A suitable cover and frame set is the floating cover and frame set 600.

Labko Oil Separator Systems


TEL. INT. FAX INT. E-MAIL
14 +358 20 1285 200 +358 20 1285 280 tanks@wavin-labko.fi www.wavin-labko.fi Separators and tanks 15
January 2006

Labko Oil Separator Systems Labko Oil Separator Systems

Wavin-Labko in brief
Wavin-Labko Ltd is a Finnish company with over 40 years'
experience in developing, manufacturing and marketing of
measurement devices and various plastic products. In the field
of measurement devices we are specialized in level instruments
and alarm devices, automation and identification, and in web-
based solutions of data transfer. In the field of plastic products
we have focused our know-how on wastewater and stormwater
treatment by using various separator systems. These systems
cover the separator solutions in business and services
construction, the wastewater treatment in rural area settlements,
as well as the wastewater treatment of private houses and
summer cottages.

Wavin-Labko Ltd is a part of international Wavin Group, which


is the leader in the European market for plastic pipe systems.
Wavin Group has a presence in 27 European countries.

Wavin-Labko Ltd reserves the rights to alterations without prior notice. Due to policy of continuous
improvement in R&D, technical specifications may change. Installation shall always be made as
documented in manufacturer's instructions.
FOR STORMWATER TREATMENT
Pictorino Oy/Kirjapaino Hermes 1/2006 2.000

IN INDUSTRIAL, STORAGE AND


TRAFFIC AREAS

www.wavin-labko.fi
Wavin-Labko Ltd
Labkotie 1
FI-36240 Kangasala
FINLAND
Tel. int. +358 20 1285 200
Fax int. +358 20 1285 280
E-mail tanks@wavin-labko.fi