Vous êtes sur la page 1sur 48

TVR II Systems

Smart and Flexible Solutions


NEW PHOTO

Introducing the new TVR II Systems 3


TVR II Advantage 4
Simultaneous Heating and Cooling 5
New System Features 8
Outdoor Units 12
Indoor Units 20
Intelligent Management Control System 40
New Service Software 44
Other Accessories 44
TVR II Outside Air Solutions 45
Introducing the new TVR II Systems
A smart solution for every type of building And as with the previous version, the TVR II
Introducing a substantially improved version to is designed to maximize the comfort of the
our existing Variable Refrigerant Flow product; user by matching the cooling or heating load
the new TVR II system under the TRANE required on each zone with no overheating or
brand represents a leap on technology when under cooling, keeping the ambient temperature
compared with our previous TVR products. within 0.5 C from set point.

The new improved TVR II includes new features Indoor air quality
like simultaneous heating and cooling using The TVR II system while cooling or heating also
the new Heat Recovery series and at the same dehumidifies the indoor air and independently
time reducing the energy consumption while filters the air in each zone with no possibility of
maintaining optimum climate conditions of the cross contamination between independent zones.
building using it.
All functions necessary for filtration, cooling and
The new improved TVR II achieves higher levels of energy efficiencies in heating, ventilation and dehumidification are
both cooling (EER) and heating (COP) than the TVR, the new product fully integrated within the TVR II system.
accomplishes this by a utilizing an optimized fan design with a DC
fan motor, an improved high performance heat exchanger, Brushless The indoor air quality can be improved when
Reluctance DC inverter scroll compressors and intelligent defrost. pretreated outside air is introduced in the
building either through direct connection to the
Like its predecessor, TVR II can be applied as the main HVAC system in
indoor units (4-way cassette units) or through
a building or as a supplemental system that coordinates with an existing our new 100% fresh air concealed units.
HVAC installation to meet different application requirements.
The TVR II system can handle the integration with
The TVR II is ideal for buildings that have different requirements for future external fresh air through different solutions.
tenants, for buildings requiring tenant by tenant installation, operation
and billing. The compact size of the indoor units, the small footprint and
modularity of outdoor units and the use of small refrigerant pipes to
transport energy between outdoor and indoor units make this product the
ideal solution for existing buildings.

Individual control
The use of individual LCD zone controllers, allows users to meet their
individual comfort needs as the TVR II system will manage the refrigerant
flow to each individual zone to achieve the required cooling or
heating needed.

The controls of the TVR II are integrated on the products from the
factory, and when combined with available remote temperature sensors,
programmable controllers, centralized controller or integrated into a TVR IIs individual independent control per zone
Building Management System (BMS) you will ensure the most efficient
and reliable operation of the building climate possible.

3VRF-SLB005-EN
TVR II Advantage

Unique Features of TVR II System


Energy Efficient System
The TVR II systems automatic power consumption adjustment matches
the cooling load perfectly to the changing needs of all the individual zones

II
thus realizing energy savings. The capacity is controlled intelligently and

distributed evenly over the different zones without wasting energy.


DC INVERTER
The Energy Efficiency (EER) increases at partial load when fewer indoor
units require cooling/heating thus reducing the total power consumption.
A TVR II system does not run at full speed all the time and during a typical
daily operation a TVR II system will work for a majority of its time in the
unloading zone with a higher energy efficiency. During partial load only
the inverter compressor runs, at full load all the compressors run for fast The TVR II system allows customization towards
cooling or heating. the future where zones can be added easily,
changed or removed depending on the changing
Flexible Design needs of the end user.
The TVR II System can be customized to the highest degree. The ability to
use Heat Pump or Heat Recovery modular Outdoor Units connecting them Energy Management
together in series; or the use of larger size individual TVR II Heat Pump The optional centralized control system of
Outdoor Units, offers the greatest design flexibility possible. the TVR II system already has all the power
management data or information points of each
In total 29 different outdoor unit combinations are available that can be
individual zone. Adding the Power measurement
matched with a total of 64 different indoor units to meet any type of
software to the system allows the user to
requirements. The largest 620 MBH modules allows up to 64 indoor units
calculate the individual power consumption
to be connected, delivering comfort as far as 150m. away from the outdoor
per zone, per floor or per building. The control
unit.
software will require a digital Amp meter per
The new Optional High Static Pressure Outdoor Fan Motor allows floor Outdoor Unit and the outdoor centralized
to floor installation of the Outdoor Units when this could be the optimal controller.
solution for a particular application.

4VRF-SLB005-EN
Simultaneous Heating and Cooling
Heat Recovery
The new TVR II heat recovery systems provide
for simultaneous cooling and heating while
achieving a better energy efficiency. TVR II Heat Pump system

During this operation the refrigerant being


condensed by the indoor units in the heating
mode is used to provide part of the cooling
required by the indoor units that are in a
cooling mode at the same time; under this
condition energy consumption can be
reduced significantly. Cooling Cooling Heating Heating
14.0kW 14.0kW 14.0kW 14.0kW

TVR II Heat Recovery system

Cooling Heating Heating Heating


14.0kW 14.0kW 14.0kW 14.0kW

Example of TVR II
Heat Recovery system

5VRF-SLB005-EN
DC Inverter Advantage
Energy Saving Graph 1
The introduction of high efficiency DC inverter scroll compressor driven
by the latest in control technology is designed to provide more precise
operation and improved system efficiency.

The compressor speed is adapted to match the fluctuating cooling/heating


load of the complete building while ensuring the right individual variable
supply of cooling/heating for each independent zone.

The control system uses PWM (Pulse Width Modulation) control that Graph 2
optimizes the efficiency once the set temperature is reached, avoiding
temperature fluctuation and thus reducing the power consumption.

Acurate temperature control leading to Ideal comfort


Graph 1: Traditional Air conditioners maintain the temperature by
continually starting and stopping the compressor after reaching the
temperature set points.

Traditional compressors require a minimum time between start and stops Longevity
which lead to large fluctuation of indoor temperature. The DC Inverter scroll compressors do not start
and stop all the time and thus will have a longer
Graph 2: With advanced digital variable refrigerant flow control technology, lifetime compared to standard compressors used
TVR II system can accurately control the room temperature within a in traditional systems.
narrow temperature band thus avoiding wasting energy and creating the The electronic control can adjust/optimize the
most comfortable environment. The set point will be stable at +/- 0.5 C. compressors working conditions in tougher
conditions, by changing the compressor speed
TVR II Energy Efficiency during cold winter conditions or high summer
outdoor temperatures. This drastically extends
the lifetime operation of the compressors.
EER (W/W)
5 The TVR II systems auto diagnostic features
COP (W/W)
4.5 4.29 4.39 4.14 4.17 carefully monitors continuously the complete
4.02 4.02
3.89
4 system and allows fast troubleshooting with the
3.70
3.5 3.25 3.21 display of alarm codes on controllers or through
3
the BMS interfaces.
2.5
2

1.5
1

0.5
0
4TVH0086 4TVH0096 4TVH0115 4TVH0140 4TVH0155

6VRF-SLB005-EN
DC Inverter scroll compressor
technology advantages
New structure-enhanced mid-frequency Environment - R410A refrigerant
performance The TVR II system operates with the highly
Specially designed scroll profile for R410A efficient R410A refrigerant with zero ozone
layer depleting potential. R410A provides
Advanced permanent magnet DC motor increased system performance and heat
improves the low frequency band transfer resulting in reduced pipe sizes, reduces
performance refrigerant quantity and installation cost savings.

The high efficiency R-410A scroll high


pressure dome compressor has a revolutionary
asynchronous motor design using integrated
permanent Neodymium magnets creating a
magnetic field with extra reluctance torque
increasing drastically the efficiencies in low and
medium speeds.

The motor will position itself, due to the


magnetic field, in the perfect start up position
allowing to the compressor to have a soft start
with the lowest Amp draw.

7VRF-SLB005-EN
New System Features
The TVR II product portfolio offers a wide range of outdoor units to meet the right needs of different
applications. There are four different types of outdoor units that can be matched to our new TVR II
indoor units:
Mini TVR II: Capacity range from 40 to 55 MBH in 50 and 60 Hz.*
Modular TVR II Heat Pump: Capacity range from 86 to 620 MBH in 50 and 60 Hz*
Individual TVR II Heat Pump: Capacity range from 180 to 290 MBH in 50 and 60 Hz*
Modular TVR II Heat Recovery: Nominal capacity range from 86 to 288 MBH in 50 and 60 Hz*
* see outdoor unit specs for more details

Self-Addressing of indoor units


The outdoor unit will automatically distribute the addresses to indoor units without any
manual settings (this function applies to vertical discharge heat pump units only).
Wireless controller TCONTRM05B can modify every indoor units address.
Max. 64 indoor units can be connected to one system and identified automatically.

Need to set the Automatically

II
address manually,
Identify
DC INVERTER
one by one

DC INVERTER

Outdoor unit static pressure


Optional adjustable high static outdoor fan motor is available for different
applications. Units can be customized to reach 40Pa external static pressure.
The standard static pressure is 0-20Pa.

New DC fan motor


The DC fan motor offers substantial improvements in operating efficiency
compared to conventional AC motors, especially during low speed rotation.

To achieve the minimum energy consumption and best performance, it


controls the speed of DC fan according to the running load and system pressure.

This new DC fan motor also reduces noise level when working in certain
part-load conditions

8VRF-SLB005-EN
Auto-rotation of Outdoor Units
When more than one outdoor unit are installed together as a modular system, the TVR II system rotates the masters unit
automatically to ensure a longer life cycle of the complete system. This is rotation takes place when the unit re-starts operation
after reaching a setpoint, after the oil return process, and after the defrost process (in heating operation).

Priority Mode Selection New High Performance Heat Exchanger


Several kinds of priority mode selection are The new TVR II units have a new high performance heat exchanger that
available to satisfy priority needs and reduces allows better air flow and longer time of operation in between defrost cycles.
the potential for mode conflict.

Heating Priority
(default)

Cooling Priority Cooling Only

New profile fan blade


New blade with sharp edge and little curve increases the airflow Rate
First unit ON Heating Mode and lowers down vibration and airflow resistance.

9VRF-SLB005-EN
Flexibility & Reliability of TVR II System
Piping Length Flexibilities
The unique concept of a pre-engineered system that arrives on the jobsite A
with a predefined piping layout per system and the necessary piping kits DC INVERTER
II

allows for fast and correct installation of the system.

The actual piping length from the condensing unit to the indoor unit
furthest away is 150m (175m equivalent) up to a total piping length
of 500m**. B
The height difference can be 70m equivalent for Outdoor Units being D
installed on the roof and 70m lift as well for Outdoor Units installed below
or on ground level. Contact your local office if over 50m lift is required
when outdoor units are installed on ground level.

C
Modular Design
By the compact modular design the TVR II Outdoor Units can be installed
in rows and manifold in series together to maximum 180kW, with 64 indoor
units connected, providing a clean accessible installation. The 180kW
Outdoor Unit is however capable to control down to a 3.6kW capacity with Maximum Actual piping length (A+B+C) 150m
only one inverter compressor running. Maximum height between indoor units (D) 15m
Maximum height between indoor units and outdoor 70m*
The combined compressors will sequentially increase the capacity using the units (B)

multiple inverter and on off compressors. Total Actual pipe length 500m**

* Contact your local office if a job requires more than 50m height.
The compact shape allows transport by elevator. ** for systems > 85kW

Back Up function
Inverter Compressor When a module fails, whether it is a slave unit or
ON/OFF Compressor a master unit, the other modules can continue to
Linear control from 2% to 100% work together as one system provided the gas/
liquid valves of the broken down unit are closed.

0 RT As the load increases the different condensing


f 5
lo
Capacity

modules will work as a master slave system


ro
ont optimizing the performance and energy
C
efficiency.

0% Load 100%

10VRF-SLB005-EN
Operation Range
[C]
The HP systems can provide either cooling or heating, while the HR
50 TVR II HP TVR II Mini TVR II HR
systems can provide cooling and heating simultaneously. 48C 48C 48C
43C
40

The TVR II mini condensing units have a low ambient operation kit 30
30C
27C 27C
standard therefore the cooling performance and the intelligent controls 20 25C

on the DC inverter compressor allow for a stable indoor temperature 10

with continuous operation in heating down to -20C for TVR II and 0 -5C -5C -5C

-15C TVR II mini. -10


-20C
-15C -15C -15C

-20
Indoor comfort level
The integration of DC inverter technology used in the condensing unit
results in an industry leading low noise level. 57 dB(A) at 1m for a 28kW
The variety of ducted indoor units allow
Outdoor Unit.
for a flexible design meeting any sound
The noise level of the indoor units is low due to the specially designed requirements per zone.
fans and heat exchanger designs

II

DC INVERTER

21
dB (A)
20 dB (A) 30 dB (A) 40 dB (A) 50 dB (A)
Speak in a low voice Quiet language Quiet reading room Quiet office
at 1/5m away laboratory
Noise decibel
* applicable for low air volume operation of 4TVD0007 units.

11VRF-SLB005-EN
Outdoor Units

TVR II Mini - Residential


Comfort 60 and 50 Hz
A very compact condensing unit that allows the
TVR II Indoor unit range to be connected to a
single outdoor unit.
Features 4TVR0040-55 (50 Hz / 1Ph)
3 power levels 12, 14, y 16 kW (50 Hz) 4TVR0040-55 (50 Hz / 3Ph)
12, 14, y 16 kW (60 Hz) 4TVR0040-55 (60 Hz / 1Ph)
4TVR0040-55 (60 Hz / 3Ph)
High Efficiency Heat Pump unit with R410A
DC inverter fan motor
Low starting current thanks to the DC inverter
Compact
technology
Maximum economy of space, one 16kW
outdoor unit controls up to maximum 7 Flexibility
indoor units Easy to install, fits inside an elevator, no need
for a crane
Can be installed close to a wall
Long piping length for spot cooling or
Low Noise
heating, 70m equivalent piping and 30m
Very low noise level on the outdoor unit,
height difference when OD unit is above
57 dB(A) at 1 meter from the unit

12VRF-SLB005-EN
Mini TVR II Condensing Units - 50Hz
Model Numbers 4TVH0040BB0 4TVH0048BB0 4TVH0055BB0 4TVH0040BD0 4TVH0048BD0 4TVH0055BD0
Power Input V/Ph/Hz 220-240/50/1 220-240/50/1 220-240/50/1 380-415/50/3 380-415/50/3 380-415/50/3
kW 12 14 15.5 12 14 15.5
Capacity
Btu/h 40,900 47,800 52,900 40,900 47,800 52,900
Cooling Power Input W 3250 3950 4520 3250 3950 4520
Capacity Range (50% - 130%) MBh 20 - 53 24 - 62 26 - 68 20 - 53 24 - 62 26 - 68
EER W/W 3.69 3.54 3.43 3.69 3.54 3.43
kW 13.2 15.4 17 13.2 15.4 17
Capacity
Btu/h 45,000 52,500 58,020 45,000 52,550 58,020
Heating Power Input W 3470 4160 4770 3470 4160 4770
Capacity Range (50% - 130%) MBh 23 - 58 26 - 68 29 - 75 23 - 58 26 - 68 29 - 75
COP W/W 3.8 3.7 3.56 3.8 3.7 3.56
Cooling operation range C -15 C ~ 48 C -15 C ~ 48 C
Heating Operating range C -15 C ~ 27 C -15 C ~ 27 C
Air Flow (H/L) m3/h 6000 6000 6000 6000 6000 6000
Sound Pressure (H/L) dB(A) 57 57 57 57 57 57
Fin Type Hydrophilic aluminum Hydrophilic aluminum
Dimensions (W/H/D) mm 900 /1327 /320 900 /1327 /320
Net weight kg 95 95 100 95 95 102
Refrigerant R410A R410A
Refrigerant Charge kg 3300 3900 3900 3300 3900 3900
FV50S FV50S FV50S
Refrigerant Oil ml FV50S 870ml FV50S 1400ml
870ml+630ml 870ml+630ml 1400ml+250ml
Liquid Side mm 9.52 9.52 9.52 9.52 9.52 9.52
Gas Side mm 15.9 15.9 19.1 15.9 15.9 19.1
Refrigerant Piping Max. Equivalent Pipe Length m 70 70
Max. Height difference between IUs m 8 8
Max. Height difference for OU above IU m 30 30
Max. Amount of IUs connected to OU 6 6 7 6 6 7
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1m in front of the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

Mini TVR II Condensing Units - 60Hz


Model Numbers 4TVH0040B10 4TVH0048B10 4TVH0055B10 4TVH0040BK0 4TVH0048BK0 4TVH0055BK0
Power Input V/Ph/Hz 208-230/60/1 208-230/60/1 208-230/60/1 380-415/60/3 380-415/60/3 380-415/60/3
kW 12 14 15.5 12 14 15.5
Capacity
Btu/h 40,900 47,800 52,900 40,900 47,800 52,900
Cooling Power Input W 3250 3950 4520 3250 3950 4520
Capacity Range (50% - 130%) MBh 20 - 53 24 - 62 26 - 68 20 - 53 24 - 62 26 - 68
EER W/W 3.69 3.54 3.43 3.69 3.54 3.43
kW 13.2 15.4 17 13.2 15.4 17
Capacity
Btu/h 45,000 52,500 58,020 45,000 52,500 58,020
Heating Power Input W 3470 4160 4770 3470 4160 4770
Capacity Range (50% - 130%) MBh 23 - 58 26 - 68 29 - 75 23 - 58 26 - 68 29 - 75
COP W/W 3.8 3.7 3.56 3.8 3.7 3.56
Cooling operation range C -15 C ~ 48 C -15 C ~ 48 C
Heating Operating range C -15 C ~ 27 C -15 C ~ 27 C
Air Flow (H/L) m3/h 6000 6000
Sound Pressure (H/L) dB(A) 57 57
Fin Type Hydrophilic aluminum Hydrophilic aluminum
Dimensions (W/H/D) kg 900 /1327 /320 900 /1327 /320
Net weight 95 95 102 92 95 102
Refrigerant kg R410A R410A
Refrigerant Charge ml 3300 3900 3900 3300 3900 3900
FV50S FV50S "FV50S
Refrigerant Oil mm FV50S 870ml FV50S 870ml FV50S 1400ml
870ml+630ml 870ml+630ml 1400ml+250ml"
Liquid Side mm 9.52 9.52
Gas Side m 15.9 15.9 19.1 15.9 15.9 19.1
Refrigerant Piping Max. Equivalent Pipe Length m 70 70
Max. Height difference between IUs m 8 8
Max. Height difference for OU above IU 30 30
Max. Amount of IUs connected to OU 6 6 7 6 6 7
* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1m in front of the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

13VRF-SLB005-EN
TVR II Modular Heat Pump Outdoor Units
Condensing units - 60 and 50 Hz
Choice of 3 ~ power supplies:
50 Hz 380V-415 V
60 Hz 380V-415 V
60 Hz 220V

5 different modules can work individually or in a master-slave


configuration up to 4 outdoor units

Any outdoor unit module in a group can be the designated master


or slave

All TVR II outdoor units have the same height and depth allowing for 4TVH0086-96 4TVH0115-155
row installation

Linear Capacity control


Comfort
Continuous cooling up to -5C and heating up to -20C Auto restart function no need for re-programming

No mechanical rooms needed, fits in elevator Low noise design

Sound Pressure at 1m Back up function

dB (A) Service
60 60
60 Easy maintenance with the self diagnostic
function and test switch
59.5
59 Flexible start up procedure and automated
58.5 piping / wiring checks
58
58 Self-addressing of indoor units
57.5
57 57 Optional service software
57

56.5

56

55.5
4TVH0086 4TVH0096 4TVH0115 4TVH0140 4TVH0155

Table of Outdoor Unit Connections


Cooling Capacity kW
Combined
kW 25.2 28 33.5 40 45 53.2 56 61.5 68 73 78.5 85 90 96 101 106.5 113 118 123.5 130 135 143.2 146 151.5 158 163 168.5 175 180
ODU
MBH 86 96 115 140 155 182 192 211 236 251 270 295 310 332 347 366 391 406 425 450 465 492 205 521 546 561 580 605 620
86 x x x
96 x x xx x x x xx xx x x x x xx x x x
115 x x x x x x x
140 x x x x x x x x
155 x x x x xx x x x xx xx xx xxx xx xx xx xx xxx xxx xxx xxxx
Max No. Indoor 13 16 16 20 20 20 20 20 20 20 20 32 32 36 36 36 42 42 42 48 48 54 54 54 58 58 58 64 64

14VRF-SLB005-EN
Outdoor Units - 4TVH
<K> 4TVH0086BK0 4TVH0096BK0 4TVH0115BK0 4TVH0140BK0 4TVH0155BK0
Model Numbers <D> 4TVH0086BD0 4TVH0096BD0 4TVH0115BD0 4TVH0140BD0 4TVH0155BD0
<6> 4TVH0086B60 4TVH0096B60 4TVH0115B60 4TVH0140B60 4TVH0155B60
kW 25.2 28 33.5 40 45
Capacity
Btu/h 86,000 95,500 114,300 136,500 153,500
Cooling Power Input W 5874 7198 9054 12307 14019
Capacity Range (50% - 130%) MBh 43 - 112 48 - 124 58 - 150 69 - 177 78 - 202
EER W/W 4.29 3.89 3.7 3.25 3.21
kW 27 31.5 37.5 45 50
Capacity
Btu/h 92,100 107,500 128,000 153,500 170,600
Heating Power Input W 6150 7608 8992 11194 12788
Capacity Range (50% - 130%) MBh 46 - 120 54 - 139 64 - 166 77 - 200 85 - 222
COP W/W 4.39 4.14 4.17 4.02 3.91
Cooling Operation Range C -5 C ~ 48 C
Heating Operating Range C -20 C ~ 21 C
Air Flow m3/h 11700 11700 15600 15600 15600
Sound Pressure dB(A) 57 57 58 60 60
Fin Type Hydrophilic Aluminium
Dimensions (W/H/D) mm 960/1615/765 960/1615/765 1250/1615/765 1250/1615/765 1250/1615/765
Net Weight kg 245 245 275 325 325
Refrigerant R410A
Refrigerant Charge kg 10 10 12 15 15
Refrigerant Oil ml FVC68D / 500 ml
Liquid Side mm 12.7 12.7 12.7 15.9 15.9
Gas Side mm 25.4 25.4 25.4 31.8 31.8
Oil Balance Pipe mm 6.4 6.4 6.4 6.4 6.4
Refrigerant Piping
Max. Equivalent Pipe Length m 175
Max. Height difference between IUs m 15
Max. Height difference for OU above IU m 70
Max. Amount of IUs connected to OU 13 16 16 16 20

<K> = 380-415 V, 3 Ph, 60 Hz


<D> = 380-415V, 3 Ph, 50 Hz
<6> = 220 V, 3 Ph, 60 Hz

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1m in front of the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

Optional Accessories
TVR II Outdoor unit centralized controller
TCONTCCM02A
Digital Ampere Meter

180kW unit

TCONTCCM02A

15VRF-SLB005-EN
TVR II Modular Heat Recovery Outdoor Units
Choice of 2 power supplies:
50 Hz 380-415 V
60 Hz 220 V

Simultaneous Heating and Cooling

Modular combinations up to 84 kW (3 outdoor units combined)

Any outdoor unit can be designed as master or slave

Linear Capacity Control

High Efficiency

No mechanical rooms needed, fits in elevator

All TVR II Heat Recovery units have the same height and depth allowing
for row installation 4TVR0086 - 4TVR0096
50 & 60 Hz

4TVR0172 - 192 4TVR0258 - 288

16VRF-SLB005-EN
Heat Recovery Outdoor Units - 4TVR
<6> 4TVR0086B60 4TVR0096B60 4TVR0172B60 4TVR0182B60 4TVR0192B60
Model Numbers
<D> 4TVR0086BD0 4TVR0096BD0 4TVR0172BD0 4TVR0182BD0 4TVR0192BD0
kW 25.2 28 50.4 53.2 56
Capacity
Btu/h 86,000 95,600 172,000 181,600 191,200
Cooling Power Input W 5874 7198 12000 13300 14700
Capacity Range (50% - 130%) MBh 43 - 112 48 - 124 86 - 223 91 - 236 96 - 248
EER W/W 4.29 3.89 4.2 4 3.81
kW 27 31.5 54 58.5 63
Capacity
Btu/h 92,200 107,500 184,400 199,700 215,000
Heating Power Input W 6150 7608 12600 14300 158000
Capacity Range (50% - 130%) MBh 46 - 120 54 - 140 92 - 239 100 - 259 108 - 279
COP W/W 4.39 4.14 4.29 4.09 3.98
Cooling Operation Range C -5 C ~ 48 C
Heating Operating Range C -15 C ~ 24 C
Mix Mode Operating Range C -5 C ~ 30 C
Air Flow m3/h 11000 11000 22000 22000 22000
Sound Pressure dB(A) 57 57 60 61 62
Fin Type Hydrophilic aluminum
Dimensions (W/H/D) mm 960/1615/ 765 960/1615/ 765 (960+960)/1615/765 (960+960)/1615/765 (960+960)/1615/765
Net Weight kg 245 245 245*2 245*2 245*2
Refrigerant R410A
Refrigerant Charge kg 10 10 20 20 20
Refrigerant Oil ml FVC68D / 500 ml
Liquid Side mm 12.7 12.7 15.9 15.9 15.9
Gas Side mm 25.4/ 19.1 25.4/ 19.1 28.6/ 22.2 31.8/ 28.6 31.8/ 28.6
Oil Balance Pipe mm 6.4
Refrigerant Piping
Max. Equivalent Pipe Length m 175
Max. Height difference between IUs m 15
Max. Height difference for OU above IU m 50
Max. Amount of IUs connected to OU 13 13 20 20 24

<6> 4TVR0258B60 4TVR0268B60 4TVR0278B60 4TVR0288B60


Model Numbers
<D> 4TVR0258BD0 4TVR0268BD0 4TVR0278BD0 4TVR0288BD0
kW 75.6 78.4 81.2 84
Capacity
Btu/h 258,000 267,600 277,200 286,800
Cooling Power Input W 18700 20100 21800 25400
Capacity Range (50% - 130%) MBh 129 - 335 134 - 347 139 - 360 143 - 372
EER W/W 4.05 3.9 3.72 3.65
kW 81 85.5 90 94.5
Capacity
Btu/h 276,600 291,900 307,200 322,500
Heating Power Input W 196000 21600 23600 25400
Capacity Range (50% - 130%) MBh 138 - 359 146 - 379 154 - 399 161 - 419
COP W/W 4.13 3.95 3.81 3.72
Cooling Operation Range C -5 C ~ 48 C
Heating Operating Range C -15 C ~ 24 C
Mix Mode Operating Range C -5 C ~ 30 C
Air Flow m3/h 33000 33000 33000 33000
Sound Pressure dB(A) 63 63.5 64 64.5
Fin Type Hydrophilic aluminum
Dimensions (W/H/D) mm (960+960+960)/1615/765 (960+960+960)/1615/765 (960+960+960)/1615/765 (960+960+960)/1615/765
Net Weight kg 245*3 245*3 245*3 245*3
Refrigerant
Refrigerant Charge kg 30 30 30 30
Refrigerant Oil ml
Liquid Side mm 15.9 19.1 19.1 19.1
Gas Side mm 34.9/ 28.6 34.9/ 28.6 34.9/ 28.6 34.9/ 28.6
Oil Balance Pipe mm 6.4
Refrigerant Piping
Max. Equivalent Pipe Length m 175
Max. Height difference between IUs m 15
Max. Height difference for OU above IU m 50
Max. Amount of IUs connected to OU 28 28 28 32
<6> = 220 V, 3 Ph, 60 Hz
<D> = 380-415V, 3 Ph, 50 Hz

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1m in front of the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

17VRF-SLB005-EN
TVR II Individual Heat Pump Outdoor Units
Choice of 2 power supplies:
50 Hz 380-415 V
60 Hz 380-415 V

Super high capacity with only one single outdoor unit

One outdoor unit can connect up to 32 indoor units

Continuous cooling up to -5C and heating up to -20C

Advanced DC inverter technology

Linear capacity Control


4TVH0180-190 4TVH0290
50 & 60 Hz 50 Hz

Sound Pressure at 1m
Comfort
64
Auto-restart function
64
Wide range of indoor units
63.5
63 63
63 Service
62.5 Easy maintenance with self-diagnostic
62 function and test switch
61.5
Self-addressing of indoor units
61
Optional service software
60.5

60

59.5
4TVH0180 4TVH0190 4TVH0290

18VRF-SLB005-EN
Individual Outdoor Units - 4TVH
<K> 4TVH0180BK0 4TVH0190BK0
Model Numbers
<D> 4TVH0180BD0 4TVH0190BD0 4TVH0290BD0
kW 53 56 85
Capacity
Btu/h 180,800 191,100 290,000
Cooling Power Input W 16000 17000 36000
Capacity Range (50% - 130%) MBh 90-235 96-248 145-377
EER W/W 3.31 3.3 2.36
kW 59 63 95
Capacity
Btu/h 199,600 215,000 324,100
Heating Power Input W 14900 16000 31500
Capacity Range (50% - 130%) MBh 100-260 108-280 162-421
COP W/W 3.96 3.94 3.02
Cooling Operation Range C -5 C ~ 48 C
Heating Operating Range C -20 C ~ 21 C
Air Flow m3/h 23000 23000 27900
Sound Pressure dB(A) 63 63 64
Fin Type Hydrophilic aluminum
Dimensions (W/H/D) mm 1960/1615/765 1960/1615/765 2540/1615/765
Net Weight kg 460 460 655
Refrigerant R410A
Refrigerant Charge kg 18 18 21
Refrigerant Oil ml FVC68D / 500
Liquid Side mm 15.9 15.9 22
Gas Side mm 31.8 31.8 38
Oil Balance Pipe mm / / 60
Refrigerant Piping
Max. Equivalent Pipe Length m 175
Max. Height difference between IUs m 15
Max. Height difference for OU above IU m 70
Max. Amount of IUs connected to OU 20 24 32

<K> = 380-415 V, 3 Ph, 60 Hz


<D> = 380-415V, 3 Ph, 50 Hz

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1m in front of the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

Optional Accessories
TVR II Outdoor unit centralized controller
TCONTCCM02A
Digital Ampere Meter

TCONTCCM02A

19VRF-SLB005-EN
Indoor Units

4-way Cassette - 4TVC


Integrated drain pump with 750 mm lift.
The adoption of the most advanced
EXV kit is factory mounted on the unit.
3-dimensional screw fan:
Efficient air distribution
- Reduces the air resistance
Fresh Air connection possible
- Smoothes the air flow and noise level
Digital tube displaying on the display board.
- Provides uniform air speed distribution
LED can display the error code so its easier
over the heat exchanger
to check malfunction
Different optional color panels to integrate
Ultra thin machine body for an easy
into a design: White (standard), Gray, Blue
installation and maintenance. (9-27 MBH
and Black
230mm , 30-48 MBH 300mm)
Optional wireless controller or
Reserved knock out spaces for ducting up
wired controller
to 50% of the air flow, hence supplying air to
2 adjacent rooms

3-dimensional screw fan Four-way Airflow

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

20VRF-SLB005-EN
4-Way Cassette - 60 Hz
Model Numbers 4TVC0009B10 4TVC0012B10 4TVC0015B10 4TVC0018B10 4TVC0024B10 4TVC0027B10 4TVC0030B10 4TVC0034B10 4TVC0038B10 4TVC0048B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
kW 2.8 3.2 4.5 5.6 7.1 8 9 10 11.2 14
Cooling
Btu/h 9,600 12,300 6 19,100 24,200 27,300 30,700 34,100 38,200 47,800
Capacity
kW 3.2 4 5 6.3 8 9 10 11 12.5 15
Heating
Btu/h 10,900 13,600 17,100 21,500 27,300 30,700 34,100 37,500 42,700 51,200
Power Input W 60 60 71 71 94 94 173 173 173 186
Rated Current A 0.4 0.4 0.4 0.4 0.5 0.5 0.7 0.7 0.7 0.8
1590/1300 1590/1300 1590/1300 1678/1358
Air Flow (H/M/L) m3/h 847/766/640 847/766/640 864/755/658 864/755/658 1157/955/749 1236/973/729
/1090 /1090 /1090 /1115
Sound Pressure (H/M/L) dB(A) 42/38/35 42/38/35 42/38/35 42/38/35 45/42/39 45/42/39 48/45/43 48/45/43 48/45/43 50/47/44
Dimensions mm 840/230/840 840/230/840 840/230/840 840/230/840 840/230/840 840/230/840 840/300/840 840/300/840 840/300/840 840/300/840
Unit (W/H/D)
Net Weight kg 24 24 26 26 26 26 32 32 32 32
Dimensions mm 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950
(W/H/D)
Front Panel Model RAYPANELWHT001
Number
Net Weight kg 6 6 6 6 6 6 6 6 6 6
Refrigerant Liquid Side mm 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Piping Gas Side mm 12.7 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32 32 32 32 32

4-Way Cassette - 50 Hz
Model Numbers 4TVC0009BB0 4TVC0012BB0 4TVC0015BB0 4TVC0018BB0 4TVC0024BB0 4TVC0027BB0 4TVC0030BB0 4TVC0034BB0 4TVC0038BB0 4TVC0048BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
kW 2.8 3.2 4.5 5.6 7.1 8 9 10 11.2 14
Cooling
Btu/h 9,600 12,300 6 19,100 24,200 27,300 30,700 34,100 38,200 47,800
Capacity
kW 3.2 4 5 6.3 8 9 10 11 12.5 15
Heating
Btu/h 10,900 13,600 17,100 21,500 27,300 30,700 34,100 37,500 42,700 51,200
Power Input W 80 80 90 75 82 97 160 160 160 170
Rated Current A 0.4 0.4 0.4 0.4 0.5 0.5 0.7 0.7 0.7 0.8
1540/1300 1540/1300 1540/1300 1800/1500
Air Flow (H/M/L) m3/h 847/766/640 847/766/640 864/755/658 864/755/658 1157/955/749 1236/973/729
/1120 /1120 /1120 /1280
Sound Pressure (H/M/L) dB(A) 42/38/35 42/38/35 42/38/35 42/38/35 45/42/39 45/42/39 48/45/43 48/45/43 48/45/43 50/47/44
Dimensions mm 840/230/840 840/230/840 840/230/840 840/230/840 840/230/840 840/230/840 840/300/840 840/300/840 840/300/840 840/300/840
Unit (W/H/D)
Net Weight kg 24 24 26 26 26 26 32 32 32 32
Dimensions mm 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950 950/46/950
(W/H/D)
Front Panel Model RAYPANELWHT001
Number
Net Weight kg 6 6 6 6 6 6 6 6 6 6
Refrigerant Liquid Side mm 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Piping Gas Side mm 12.7 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32 32 32 32 32

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

21VRF-SLB002-EN
21VRF-SLB005-EN
Compact 4-way Cassette -
4TVB
Comfort
360 efficient air distribution Quick installation
Three level fan speed that meets different air Ultra thin body of 265mm for installation in
supply requirements tight ceilings

Optimum air flow thanks to the 3-Dimensional Light weight units are easy to mount
Screw fan Integrated drain pump that lifts up to
3-Dimensional
Screw Fan - Reduced Air resistance 500mm

- Smoothes the air flow and noise level Flexibility


1 panel size 647mm x 647mm that fits in
- Provides uniform air speed distribution over
standard ceiling grids for all 4 different sizes
the entire coil

Built in Auto Restart

Four-way Airflow Fresh Air connection possible


570 mm

630 mm

Compact
Cassette Panel

265 mm

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

22VRF-SLB005-EN
Compact 4-Way Cassette 60 Hz
Model Numbers 4TVB0007B10 4TVB0009B10 4TVB0012B10 4TVB0015B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
kW 2.2 2.8 3.6 4.5
Cooling
Btu/h 7,500 9,600 12,300 15,400
Capacity
kW 2.4 3.2 4 5
Heating
Btu/h 8,200 10,900 13,600 17,100
Power Input W 51 52 58 58
Rated Current A 0.175 0.175 0.21 0.21
Air Flow (H/M/L) m3/h 532/397/292 539/408/310 632/496/359 632/496/359
Sound Pressure dB(A) 38.1/33.4/23.4 38.1/33.4/23.4 41.5/35.6/28.8 41.5/35.6/28.8
Dimensions (W/H/D) mm 630/265/570 630/265/570 630/265/570 630/265/570
Unit
Net Weight kg 17.5 17.5 19 19
Dimensions (W/H/D) mm 647/50/647 647/50/647 647/50/647 647/50/647
Front Panel Model Number RAYCMPCTPNL002
Net Weight kg 3 3 3 3
Liquid Side mm 6.35 6.35 6.35 6.35
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7
Drainage Water Pipe (OD) mm 25 25 25 25

Compact 4-Way Cassette 50 Hz


Model Numbers 4TVB0007B10 4TVB0009B10 4TVB0012B10 4TVB0015B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
kW 2.2 2.8 3.6 4.5
Cooling
Btu/h 7,500 9,600 12,300 15,400
Capacity
kW 2.4 3.2 4 5
Heating
Btu/h 8,200 10,900 13,600 17,100
Power Input W 51 52 58 58
Rated Current A 0.175 0.175 0.21 0.21
Air Flow (H/M/L) m3/h 532/397/292 539/408/310 632/496/359 632/496/359
Sound Pressure dB(A) 38.1/33.4/23.4 38.1/33.4/23.4 41.5/35.6/28.8 41.5/35.6/28.8
Dimensions (W/H/D) mm 630/265/570 630/265/570 630/265/570 630/265/570
Unit
Net Weight kg 17.5 17.5 19 19
Dimensions (W/H/D) mm 647/50/647 647/50/647 647/50/647 647/50/647
Front Panel Model Number RAYCMPCTPNL002
Net Weight kg 3 3 3 3
Liquid Side mm 6.35 6.35 6.35 6.35
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7
Drainage Water Pipe (OD) mm 25 25 25 25

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

23VRF-SLB005-EN
2-Way Cassette - 4TVG
Flexibility
Compact design Comfort

Standard built-in drain pump (750 mm) Low sound level (24 dB (A) on 7 MBH unit)

One panel size for all models (from 7 to 24 MBH) Efficient air distribution

Front panel RAYTWOWAYPNL01 Built-in Auto-restart

Standard filter

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

24VRF-SLB005-EN
2-Way Cassette 60 Hz
Model Numbers 4TVG0007B10 4TVG0009B10 4TVG0012B10 4TVG0015B10 4TVG0018B10 4TVG0024B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
kW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Capacity
kW 2.6 3.2 4 5 6.3 8
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,300
Power Input W 57 57 60 92 108 154
Rated Current A 0.35 0.45 0.45 0.55 0.55 0.75
Air Flow (H/M/L) m3/h 674/509/381 674/509/381 740/577/435 878/689/561 941/776/654 1236/1110/864
Sound Pressure dB(A) 33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34
Dimensions (W/H/D) mm 1172/300/592 1172/300/592 1172/300/592 1172/300/592 1172/300/592 1172/300/592
Unit
Net Weight kg 34 34 34 36.5 36.5 36.5
Dimensions (W/H/D) mm 1430/53/680 1430/53/680 1430/53/680 1430/53/680 1430/53/680 1430/53/680
Front Panel Model Number RAYTWOWAYPNL01
Net Weight kg 10.5 10.5 10.5 10.5 10.5 10.5
Liquid Side mm 6.35 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32

2-Way Cassette 50 Hz
Model Numbers 4TVG0007BB0 4TVG0009BB0 4TVG0012BB0 4TVG0015BB0 4TVG0018BB0 4TVG0024BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
kW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Capacity
kW 2.6 3.2 4 5 6.3 8
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,300
Power Input W 57 57 60 92 108 154
Rated Current A 0.35 0.45 0.45 0.55 0.55 0.75
Air Flow (H/M/L) m3/h 654/530/410 654/530/410 725/591/458 850/670/550 980/800/670 1200/1000/770
Sound Pressure dB(A) 33/29/24 36/32/29 36/32/29 39/35/30 39/35/30 44/40/34
Dimensions (W/H/D) mm 1172/300/592 1172/300/592 1172/300/592 1172/300/592 1172/300/592 1172/300/592
Unit
Net weight kg 34 34 34 36.5 36.5 36.5
Dimensions (W/H/D) mm 1430/53/680 1430/53/680 1430/53/680 1430/53/680 1430/53/680 1430/53/680
Front Panel Model Number RAYTWOWAYPNL01
Net Weight kg 10.5 10.5 10.5 10.5 10.5 10.5
Liquid Side mm 6.35 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

25VRF-SLB005-EN
1-Way Cassette - 4TVE
Flexibility
Compact design
Comfort
Standard built-in drain pump (750 mm) Low sound level (24 dB (A) on 7 MBH unit)
Two front panels Efficient air distribution
RAYONEWAYPNL01 (9 to 12 MBH) Built-in Auto-restart
RAYONEWAYPNL02 (15 to 24 MBH) Standard filter

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

26VRF-SLB005-EN
1-Way Cassette 60 Hz
Model Numbers 4TVE0009B10 4TVE0012B10 4TVE0015B10 4TVE0018B10 4TVE0024B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
kW 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 9,600 12,300 15,400 19,100 24,200
Capacity
kW 3.2 4 5 6.3 8
Heating
Btu/h 10,900 13,600 17,100 21,500 27,300
Power Input W 53 53 86 86 86
Rated Current A 0.4 0.4 0.4 0.4 0.5
Air Flow (H/M/L) m3/h 500/450/410 500/450/410 894/800/750 919/850/760 1080/980/900
Sound Pressure dB(A) 36/34/30 36/34/30 41/38/35 41/38/35 41/38/35
Dimensions (W/H/D) mm 850/400/235 850/400/235 1200/198/655 1200/198/655 1200/198/655
Unit
Net Weight kg 23 23 31 31 31
Dimensions (W/H/D) mm 1050/18/470 1050/18/470 1420/10/755 1420/10/755 1420/10/755
Front Panel Model Number RAYONEWAYPNL01 RAYONEWAYPNL02
Net Weight kg 4 4 9 9 9
Liquid Side mm 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 15.9 15.9 15.9 15.9 15.9

1-Way Cassette 50 Hz
Model Numbers 4TVE0009BB0 4TVE0012BB0 4TVE0015BB0 4TVE0018BB0 4TVE0024BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
kW 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 9,600 12,300 15,400 19,100 24,200
Capacity
kW 3.2 4 5 6.3 8
Heating
Btu/h 10,900 13,600 17,100 21,500 27,300
Power Input W 53 53 86 86 86
Rated Current A 0.3 0.3 0.4 0.4 0.45
Air Flow (H/M/L) m3/h 500/450/410 500/450/410 894/800/750 919/850/760 1080/980/900
Sound Pressure dB(A) 36/34/30 36/34/30 41/38/35 41/38/35 41/38/35
Dimensions (W/H/D) mm 850/400/235 850/400/235 1200/198/655 1200/198/655 1200/198/655
Unit
Net Weight kg 23 23 31 31 31
Dimensions (W/H/D) mm 1050/18/470 1050/18/470 1420/10/755 1420/10/755 1420/10/755
Front Panel Model Number RAYONEWAYPNL01 RAYONEWAYPNL02
Net weight kg 4 4 9 9 9
Liquid Side mm 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 15.9 15.9 15.9 15.9 15.9

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

27VRF-SLB005-EN
Low ESP Ducted Indoor
Unit - 4TVL
Comfort
Quick installation
Efficient air distribution
Ultra thin body of 190mm for both
Three level fan speed that meets different air 50 & 60 Hz models
supply requirements for installation in small false ceilings
Very low noise level - 21 dB (A) for Light weight units are easy to mount
7 MBH unit
Flexibility
Built in Auto Restart Standard EXV mounted at the factory
horizontally

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

28VRF-SLB005-EN
Low Pressure Duct 60 Hz
Model Numbers 4TVL0007B10 4TVL0009B10 4TVL0012B10 4TVL0015B10 4TVL0018B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
KW 2.2 2.8 3.6 4.5 5.6
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100
Capacity
KW 2.6 3.2 4 5 6.3
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500
Power Input W 32 35 35 43 43
Rated Current A 0.17 0.17 0.17 0.17 0.24
Air Flow (H/M/L) m3/h 452/409/310 521/460/372 521/460/372 831/712/591 831/712/591
Indoor External Static Pressure (H) Pa 5
Sound Pressure (H/M/L) dB(A) 34/29/21 36/34/30 36/34/30 37/35/31 37/35/31
Dimensions (W/H/D) mm 850/190/405 850/190/405 850/190/405 1030/190/430 1030/190/430
Net Weight kg 11.5 11.5 11.5 14 14
Liquid Side mm 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 20

Low Pressure Duct 50 Hz


Model Numbers 4TVL0007BB0 4TVL0009BB0 4TVL0012BB0 4TVL0015BB0 4TVL0018BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KW 2.2 2.8 3.6 4.5 5.6
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100
Capacity
KW 2.6 3.2 4 5 6.3
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500
Power Input W 40 40 40 40 56
Rated Current A 0.17 0.17 0.17 0.17 0.24
Air Flow (H/M/L) m3/h 446/323/250 446/323/250 527/359/267 767/634/512 767/634/512
Indoor external static pressure (H) Pa 5
Sound Pressure (H/M/L) dB(A) 34/29/21 36/34/30 36/34/30 37/35/31 37/35/31
Dimensions (W/H/D) mm 850/190/405 850/190/405 850/190/405 1030/190/430 1030/190/430
Net weight kg 11.5 11.5 11.5 14 14
Liquid Side mm 6.35 6.35 6.35 9.52 9.52
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7 15.9
Drainage water pipe (OD) mm 20

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

29VRF-SLB005-EN
Medium ESP Ducted
Indoor - 4TVD
Comfort Quick installation
Three level fan speed that meets different air Ultra thin body of 210mm height for
supply requirements installation in small ceiling pocket
Low noise level thanks to the fan blade design Light weight units are easy to mount
Built in Auto Restart Flexibility
Standard long life filter Different installations patterns possible with
bottom return or ducted return

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

30VRF-SLB005-EN
Mid Pressure Duct 60 Hz
Model Numbers 4TVD0007B10 4TVD0009B10 4TVD0012B10 4TVD0015B10 4TVD0018B10 4TVD0024B10 4TVD0027B10 4TVD0030B10 4TVD0038B10 4TVD0048B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
kW 2.2 2.8 3.2 4.5 5.6 7.1 8 9 11.2 14
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 27,300 30,700 38,200 47,800
Capacity
kW 2.6 3.2 4 5 6.3 8 9 10 12.5 15.5
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,300 30,700 34,100 42,650 52,900
Power Input W 66 72 77 101 100 125 133 134 378 352
Rated Current A 0.28 0.28 0.28 0.5 0.5 0.7 1.16 1.16 1.65 1.8
Air Flow (H/M/L) m3/h 476/399/335 476/399/335 534/452/391 746/558/470 750/563/470 998/820/607 1226/1018/861 1230/1019/859 1750/1552/1389 1789/1539/1250
Indoor External Static Pa 10(10~30) 10(10~30) 10(10~30) 10(10~30) 10(10~30) 10(10~30) 20(10~50) 20(10~50) 40(10~80) 40(10~100)
Pressure (H)
Sound Pressure (H/M/L) dB(A) 38/35/32 38/35/32 40/38/36 41/38.9/36 41/38.9/36 42/40/35 45.4/39.8/37 45.4/39.8/37 48.0 /41.9/38 47.7/43.2/39.0
Dimensions (W/H/D) mm 700/210/635 700/210/635 700/210/635 920/210/635 920/210/635 1140/210/635 1140/270/775 1140/270/775 1140/270/775 1200/300/865
Net weight kg 21.5 21.5 22 27 27 31.8 38 40 40 49
Liquid mm 6.35 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Refrigerant Side
Piping Gas mm 12.7 12.7 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9
Side
Drainage Water Pipe (OD) mm 32 32 32 32 32 32 32 32 32 32

Mid Pressure Duct 50 Hz


Model Numbers 4TVD0007BB0 4TVD0009BB0 4TVD0012BB0 4TVD0015BB0 4TVD0018BB0 4TVD0024BB0 4TVD0027BB0 4TVD0030BB0 4TVD0038BB0 4TVD0048BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
kW 2.2 2.8 3.2 4.5 5.6 7.1 8 9 11.2 14
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 27,300 30,700 38,200 47,800
Capacity
kW 2.6 3.2 4 5 6.3 8 9 10 12.5 15.5
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,300 30,700 34,100 42,650 52,900
Power Input W 57 57 61 92 92 125 198 200 313 274
Rated Current A 0.28 0.28 0.28 0.5 0.5 0.7 1.16 1.16 1.65 1.8
Air Flow (H/M/L) m3/h 530/410/320 530/410/320 530/410/320 850/667/583 850/667/583 998/820/607 1226/1018/861 1226/1018/861 1752/1552/1389 1918/1539/1250
Indoor External Static Pa 10(10~30) 10(10~30) 10(10~30) 10(10~30) 10(10~30) 10(10~30) 20(10~50) 20(10~50) 40(10~80) 40(10~80)
Pressure (H)
Sound Pressure (H/M/L) dB(A) 38/35/32 38/35/32 40/38/36 41/38.9/36 41/38.9/36 42/40/35 45.4/39.8/37 45.4/39.8/37 48.0 /41.9/38 47.7/43.2/39.0
Dimensions (W/H/D) mm 700/210/635 700/210/635 700/210/635 920/210/635 920/210/635 1140/210/635 1140/270/775 1140/270/775 1140/270/775 1200/300/865
Net weight kg 21.5 21.5 22 27 27 31.8 38 40 40 49
Liquid mm 6.35 6.35 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Refrigerant Side
Piping Gas mm 12.7 12.7 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9
Side
Drainage Water Pipe (OD) mm 32 32 32 32 32 32 32 32 32 32

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

31VRF-SLB002-EN
31VRF-SLB005-EN
High ESP Ducted
Indoor - 4TVA
Comfort
Three level fan speed that meets different air
supply requirements

Built in Auto Restart

Air filter to be fitted inside return duct system

Flexibility
Broad range of models up to 95 MBH in 50 Hz
and 55 MBH in 60 Hz
External Static Pressure up to 196 Pa

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

32VRF-SLB005-EN
High Pressure Duct 60Hz
Model Numbers 4TVA0024B10 4TVA0027B10 4TVA0030B10 4TVA0038B10 4TVA0048B10 4TVA0055B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
KW 7.1 8 9 11.2 14 16
Cooling
Btu/h 24,200 27,300 30,700 38,200 47,800 54,600
Capacity
KW 8 9 10 12.5 16 18
Heating
Btu/h 27,300 30,700 34,100 42,650 54,600 61,400
Power Input W 414 402 409 524 627 832
Rated Current A 1.1 1.1 1.8 2.3 2.7 3.6
Air Flow (H/M/L) m3/h 1758/1568/1342 1602/1494/1302 2250/2020/1595 2250/2020/1595 3030/2711/2490 3030/2711/2490
Indoor External Static Pressure (H) Pa 40(30~ 196) 40(30~ 196) 40(30~ 196) 50(30~ 196) 50(30~ 196) 50(30~ 196)
Sound Pressure (H/M/L) dB(A) 48/46/44.5 48/46/44.5 52/49/47 52/49/47 53/50/48 54/52/50
Dimensions (W/H/D) mm 952/420/690 952/420/690 952/420/690 952/420/690 1200/400/600 1200/400/600
Net Weight kg 46.5 46.5 50 50.6 70 70
Liquid Side mm 9.52 9.52 9.52 9.52 9.52 9.52
Refrigerant Piping
Gas Side mm 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water Pipe (OD) mm 32 32 32 32 32 32

High Pressure Duct 50Hz


Model Numbers 4TVA0024BB0 4TVA0027BB0 4TVA0030BB0 4TVA0038BB0 4TVA0048BB0 4TVA0055BB0 4TVA0068BB0 4TVA0085BB0 4TVA0095BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KW 7.1 8 9 11.2 14 16 20 25 28
Cooling
Btu/h 24,200 27,300 30,700 38,200 47,800 54,600 68,250 85,300 95,600
Capacity
KW 8 9 10 12.5 16 18 22.5 26 31.5
Heating
Btu/h 27,300 30,700 34,100 42,650 54,600 61,400 76,800 88,700 107,500
Power Input W 263 263 423 524 627 832 1516 1516 1516
Rated Current A 1.1 1.1 1.8 2.3 2.7 3.6 6.6 6.6 6.6
1510/1399 1500/1396 1936/1721 2117/1950 2988/2670 3890/3200 4268/3780 4280/3820 4400/3708
Air Flow (H/M/L) m3/h
/1236 /1221 /1511 /1644 /2229 /2700 /3200 /3200 /3200
Indoor External Static
Pa 40(30~ 196) 40(30~ 196) 40(30~ 196) 50(30~ 196) 50(30~ 196) 50(30~ 196) 140(50~250) 140(50~250) 140(50~250)
Pressure (H)
Sound Pressure (H/M/L) dB(A) 48/46/44 48/46/44.5 52/49/47 52/49/47 53/50/48 54/52/50 59/55/52 59/55/52 59/55/52
Dimensions (W/H/D) mm 952/420/690 952/420/690 952/420/690 952/420/690 1200/400/600 1200/400/600 1425/500/928 1425/500/928 1425/500/928
Net Weight kg 45 45 46.5 50.6 68 70 115 115 115
Liquid
Refrigerant mm 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Side
Piping
Gas Side mm 15.9 15.9 15.9 15.9 15.9 15.9 15.9 *2 15.9 *2 15.9 *2
Drainage Water Pipe (OD) mm 32 32 32 32 32 32 32 32 32

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

33VRF-SLB005-EN
Convertible - 4 TVX
Comfort
Efficient air distribution with two directional
airflow and wide angle air flow
Three level fan speed that meets different air
supply requirements
Low noise level
Built in Auto Restart
Quick installation
Ultra thin body of 206mm and 660mm height
for installation under windows or ceilings
Flexibility
Light weight units are easy to mount
Modern and elegant appearance
Drain pipe connection left or right
Can be installed vertically and horizontally

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

34VRF-SLB005-EN
Convertible 60 Hz
Model Numbers 4TVX0012B10 4TVX0015B10 4TVX0018B10 4TVX0024B10 4TVX0030B10 4TVX0038B10 4TVX0048B10 4TVX0055B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
KW 3.6 4.5 5.6 7.1 8 9 11.2 14
Cooling
Btu/h 12,300 15,400 19,100 24,200 27,300 30,700 38,200 47,800
Capacity
KW 4 5 6.3 8 9 10 12.5 15.5
Heating
Btu/h 13,600 17,100 21,500 27,300 30,700 34,100 42,650 52,900
Power Input W 49 147 147 147 185 185 241 241
Rated Current A 0.55 0.55 0.55 0.57 0.6 0.6 0.83 0.83
Air Flow (H/M/L) m3/h 600/ 480/ 400 750/650/550 750/650/550 750/650/550 1200/900/700 1200/900/700 1980/1860/1730 1980/1860/1730
Sound Pressure (H/M/L) dB(A) 40/38/36 43/41/38 43/41/38 43/41/38 45/43/40 45/43/40 47/45/42 47/45/42
Dimensions (W/H/D) mm 990/660/206 990/660/206 990/660/206 990/660/206 1280/660/206 1280/660/206 1670x680x244 1670x680x244
Net Weight kg 26 28 28 28 34.5 34.5 54 54
Refrigerant Liquid Side mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Piping Gas Side mm 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water
mm 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9
Pipe (OD)

Convertible 50 Hz
Model Numbers 4TVX0012BB0 4TVX0015BB0 4TVX0018BB0 4TVX0024BB0 4TVX0030BB0 4TVX0038BB0 4TVX0048BB0 4TVX0055BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KW 3.6 4.5 5.6 7.1 8 9 11.2 14
Cooling
Btu/h 12,300 15,400 19,100 24,200 27,300 30,700 38,200 47,800
Capacity
KW 4 5 6.3 8 9 10 12.5 15.5
Heating
Btu/h 13,600 17,100 21,500 27,300 30,700 34,100 42,650 52,900
Power Input W 49 120 122 125 130 130 182 182
Rated Current A 0.55 0.55 0.55 0.57 0.6 0.6 0.83 0.83
Air Flow (H/M/L) m3/h 650/570/500 800/600/500 800/600/500 800/600/500 1200/900/700 1200/900/700 1980/1860/1730 1980/1860/1730
Sound Pressure (H/M/L) dB(A) 40/38/36 43/41/38 43/41/38 43/41/38 45/43/40 45/43/40 47/45/42 47/45/42
Dimensions (W/H/D) mm 990/660/206 990/660/206 990/660/206 990/660/206 1280/660/206 1280/660/206 1670/680/244 1670/680/244
Net Weight kg 26 28 28 28 34.5 34.5 54 54
Refrigerant Liquid Side mm 6.35 6.35 9.52 9.52 9.52 9.52 9.52 9.52
Piping Gas Side mm 12.7 12.7 15.9 15.9 15.9 15.9 15.9 15.9
Drainage Water
mm 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9
Pipe (OD)

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located at a distance of 1 m (horizontal) and 1 m (vertical) from the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

35VRF-SLB002-EN
35VRF-SLB005-EN
7 to 18 MBH
Wall Mounted Indoor Unit
- 4TVW
Comfort
Double air guides for optimum air distribution

Three level fan speed that meets different air


supply requirements (7 -18 MBH)

Built in Auto Restart 24 MBH

Low noise 29dB(A) for 3.6kW model

Quick Installation
LED display integrated, allows trouble
Flexibility
shooting
Slim design with an easy to clean mirror
Multi position piping possibilities (7 to 18 MBH)

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

36VRF-SLB005-EN
High Walls 60 Hz
Model Numbers 4TVW0007B10 4TVW0009B10 4TVW0012B10 4TVW0015B10 4TVW0018B10 4TVW0024B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
KW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,232
Capacity
KW 2.6 3.2 4 5 6.3 8
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,304
Power Input W 28 28 28 45 45 79
Rated Current A 0.14 0.14 0.14 0.2 0.2 0.33
Air Flow (H/M/L) m3/h 557/520/467 557/520/467 557/520/467 842/722/597 842/722/597 1190/880/680
Sound Pressure (H/M/L) dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34 47
Dimensions (W/H/D) mm 915/290/210 915/290/210 915/290/210 1070/315/210 1070/315/210 1250/325/230
Net Weight kg 12 12 12 16 16 19.9
Liquid Side mm 6.35 6.35 6.35 6.35 9.52 9.5
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 16.5 16.5 16.5 16.5 16.5 16.5

High Walls 50 Hz
Model Numbers 4TVW0007BB0 4TVW0009BB0 4TVW0012BB0 4TVW0015BB0 4TVW0018BB0 4TVW0024BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KW 2.2 2.8 3.6 4.5 5.6 7.1
Cooling
Btu/h 7,500 9,600 12,300 15,400 19,100 24,232
Capacity
KW 2.6 3.2 4 5 6.3 8
Heating
Btu/h 8,900 10,900 13,600 17,100 21,500 27,304
Power Input W 28 28 28 45 45 79
Rated Current A 0.14 0.14 0.14 0.2 0.2 0.33
Air Flow (H/M/L) m3/h 520/480/430 520/480/430 520/480/430 860/755/630 925/860/755 1190/880/680
Sound Pressure (H/M/L) dB(A) 35/32/29 35/32/29 35/32/29 40/38/34 40/38/34 47
Dimensions (W/H/D) mm 915/290/210 915/290/210 915/290/210 1070/315/210 1070/315/210 1250/325/230
Net Weight kg 12 12 12 16 16 19.9
Liquid Side mm 6.35 6.35 6.35 6.35 9.52 9.5
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7 15.9 15.9
Drainage Water Pipe (OD) mm 16.5 16.5 16.5 16.5 16.5 16.5

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located at a distance of 1m (horizontal) and 1 m (vertical) from the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

37VRF-SLB002-EN
37VRF-SLB005-EN
Console Type - 4TVJ
Flexibility
Compact design

It can be installed on the floor and mounted


on the wall.

Built-in EXV

Comfort
Low sound level

Vertical auto swing and wide angle louvers

Built-in Auto-restart

Standard filter

COOLING MODE
COOLING MODE HEATING MODE
HEATING MODE

quick cooling quick to


cooling to maintain temp
maintain temp anti-cold air anti-cold air operation
normal normal opera

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

38VRF-SLB005-EN
Console 60 Hz
Model Numbers 4TVJ0007B10 4TVJ0009B10 4TVJ0012B10 4TVJ0015B10
Power Supply V/Ph/Hz 220-240/1/60 220-240/1/60 220-240/1/60 220-240/1/60
KW 2.2 2.8 3.6 4.5
Cooling
Btu/h 7,500 9,600 12,300 15,400
Capacity
KW 2.6 3.2 4 5
Heating
Btu/h 8,900 10,900 13,600 17,100
Power Input W 20 25 25 45
Rated Current A 0.09 0.11 0.11 0.2
Air Flow (H/M/L) m3/h 430/345/229 510/430/229 510/430/229 510/430/229
Sound Pressure (H/M/L) dB(A) 38/32/26 39/33/27 39/33/27 42/39/36
Dimensions (W/H/D) mm 700/600/210 700/600/210 700/600/210 700/600/210
Unit
Net Weight kg 14 15 15 15
Liquid Side mm 6.35 6.35 6.35 6.35
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7
Drainage Water Pipe (OD) mm 16 16 16 16

Console 50 Hz
Model Numbers 4TVJ0007BB0 4TVJ0009BB0 4TVJ0012BB0 4TVJ0015BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KW 2.2 2.8 3.6 4.5
Cooling
Btu/h 7,500 9,600 12,300 15,400
Capacity
KW 2.6 3.2 4 5
Heating
Btu/h 8,900 10,900 13,600 17,100
Power Input W 20 25 25 45
Rated Current A 0.09 0.11 0.11 0.2
Air Flow (H/M/L) m3/h 430/345/229 510/430/229 510/430/229 510/430/229
Sound Pressure (H/M/L) dB(A) 38/32/26 39/33/27 39/33/27 42/39/36
Dimensions (W/H/D) mm 700/600/210 700/600/210 700/600/210 700/600/210
Unit
Net Weight kg 14 15 15 15
Liquid Side mm 6.35 6.35 6.35 6.35
Refrigerant Piping
Gas Side mm 12.7 12.7 12.7 12.7
Drainage Water Pipe (OD) mm 16 16 16 16

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

39VRF-SLB005-EN
Intelligent Management Control System
The TVR II system can be controlled on different user levels, from the individual user level with the zone controllers to a more
centralized tenant by tenant control or a fully integrated building control PC system with a third party BMS control system

Individual Controllers
Wireless Controller TCONTRM05B Wireless Controller TCONTRM02A
(for HP systems) (for HR systems)
Functions: LCD display, Clock, ON/ Auto-changeover mode for HR
OFF, Temp. setting, Mode setting, systems
Fan speed setting, Timer, Horizontal Functions: LCD display, Clock,
Swing, Vertical Swing, Air Direction ON/OFF, Temp. setting, Mode
Mode: Auto/Dry/Cool/Heat & Fan only setting, Fan speed setting, Timer
Timer: 0 24 hrs timer setting Addressing function TCONTRM02A

Addressing function TCONTRM05B

Wired Controller TCONTKJR90A


(for HP systems)
Wired Controller TCONTKJR120A
New Stylish Design
(for HR systems)
Functions: LCD display, Clock, ON/ Auto-changeover mode for
OFF, Temp. setting, Mode setting, HR systems
Fan speed setting, Timer
TCONTKJR90A Functions: LCD display, Clock,
Mode: Auto/Dry/Cool/Heat & Fan only ON/OFF, Temp. setting, Mode
Timer: 0 24 hrs timer setting setting, Fan speed setting, Timer TCONTKJR120A
Note: Do not use HR controllers in HP systems in
order to avoid mode conflict.
Wired Controller TCONTKJR12B
(for HP systems)
Functions: LCD display, ON/OFF,
Temp. setting, Mode setting, Fan
speed setting, Timer, Swing setting,
Lock
Mode: Auto/Dry/Cool/Heat & Fan only
Timer: 0 24 hrs timer setting TKONTKJR12B

Follow me: allows precise room


temperature control using the
Temperature sensor in the controller

40VRF-SLB005-EN
Centralized Controllers Outdoor Unit Centralized
Controller TCONTCCM02A
Indoor unit Centralized Controllers
Controls 32 outdoor units and
TCONTCCM09A (for HP systems)
a PC can control 16 OU centralized
TCONTCCM09A
TCONTCCM03HP (for HP systems) controllers

TCONTCCM03HR (for HR systems) This controller cannot be connected


directly to Mini TVR II units. TCONTCCM02A
TCONTKJR180A (new design for
HP systems) Centralized ON/OFF, Mode query,
Temp. query, Fan query, Mode lock
Functions: TCONTCCM03HP function
Group control Blue lit background LCD
TCONTCCM09 and 03 can control Emergency stop contact or forced
64 indoor units cooling start signal

TCONTKJR180A controls 16 Maximum wiring length 1,000m


indoor units TCONTKJR180A RS 232 interface to TVR II system
Centralized ON/OFF PC control

Mode setting, Temp. setting, Fan


setting, Mode lock function
Weekly timer setting (only for
TCONTCCM09)
Blue lit background LCD
Lock mode
RS232 connection to PC (only for
TCONTCCM03)

41VRF-SLB005-EN
Building Management Control
The TVR II control network can combine several centralized controllers with a PC or external BMS systems such as Tracer SC
through BACnet or MODBUS interfaces to meet customers needs in different applications. This higher level of control adds
more user friendly features such as power consumption reporting.

TVR II PC Network control software


Up to 1,200m of wiring can be extended to Compatible with Windows XP
3,000m with signal booster relay
Remote online service access possible via
Monitors the system online, records operation internet
data, reports errors
Power consumption report (requires
Manages up to max 16 Outdoor and max additional external Watt meters)
16 Indoor centralized controllers or up to
1,024 indoor units and 512 Outdoor Units

Outdoor Units
F1,F2,E K1,K2,E
TCONTCCM08A Indoor Units
MAX 4
TCONTCCM02A or TCONTCCM03 TCONTCCM02A

TCONTCCM03HP

Outdoor Units

BACnet/IP protocol

X,Y,E
TCONTCCM03HP
Indoor Units

BMS System P,Q,E

42VRF-SLB005-EN
BACnet Interface TCONTCCM08A Digital Ampmeter TCONTDTS
This gateway connects through BACnet One Amp meter per Master Outdoor Unit or
to the TVR II entire installation and other condensing system
external components through an existing
Needs to be connected to specific wiring
BMS
terminals on outdoor unit
Connects through Ethernet to BACnet/IP
Outdoor Units TVR II need
TCONTCCM08A
4 RS485 connections for connecting to 4 to have a controller TCONTCCM02A that
TVR II centralized controllers connects to PC or network.

BACnet is a registered trademark of ASHRAE. Available for models 380-415/50/3,


380-415/60/3 and 220/60/3
MODBUS Interface TCONTMODBUS
Integrates TVR II systems to BMS systems
through MODBUS.
Controls up to 1024 indoor units and 64
outdoor units
Transfers the information via the RTU mode
Wide voltage 12-48VDC

TCONTMODBUS

43VRF-SLB005-EN
New Service Software
As part of our new TVR II portfolio, we
introduce a new service tool that allows you to
diagnose and troubleshoot the system.
Model number: TCONTSERVS.
485A-l
K1,K2,E
Real time display of outdoor unit
operating parameters
Description of error codes.

Other Accessories

TCONTAHUKIT1 TCONTNAM05A
TCONTNAM09A

Trane also offers other accessories to maximize customers comfort in different applications.

Air Handler Connection Kit Motion Sensor


This kit allows you to integrate other Turns off the system when it doesnt
indoor units to the TVR II system. The sense movement in the room.
kits includes the control boards, EXV,
sensors, and wired controller. Hotel Inserting Card
Two models available: Model number: TCONTNAM05A
TCONTAHUKIT1 (14kW one circuit) and ON-OFF control
TCONTAHUKIT2 (28 kW two circuits)
Auto-restart function

44VRF-SLB005-EN
TVR II Outside Air Solutions
Indoor air quality depends on many design
factors and local codes.

The local ventilation regulations or ASHRAE62.1


will define what ventilation ratio is required per
zone and per type of application.
Features
The TVR II system offers a great level of
Outside air passes trough a heat exchanger
flexibility to adapt to any ventilation standard
and is pre cooled or preheated by the
and several design strategies can be followed.
extracted inside air, thus reducing the energy
1. Direct intake of indoor unit of pre-treated
needed to cool/heat up a room and providing
fresh air
a higher quality of indoor air comfort.
2. Direct control connection with TVR II
High efficiency Sensible and Latent heat
Energy Recovery Ventilators exchanger
3. 100% Fresh air duct units. Modular concept with zone by zone indoor
4. Separate dedicated outside air system air treatment
CDQ + rooftop. Controlled by individual wired controller
TVR II ERV available in 50 and 60 Hz TCONTKJR27B or by the TVR II Centralized
The energy recovery ventilator can be integrated controller
into the building to provide the necessary Connects easily to ductwork, dual centrifugal
ventilation volume with the added benefit of fan, single or three phase
energy recovery, thus reducing the installed
Low vibration and noise level
capacity of the TVR II system in each zone
equipped with Energy Recovery Ventilator.

Energy Recovery Ventilators


Model Numbers TERV0120A TERV0175A TERV0235A TERV0300A TERV0470A TERV0600A TERV0900A TERV1200A

V/Hz/Ph 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 220/50/1 380/50/3 380/50/3


Power Supply
V/Hz/Ph - - 220/60/1 220/60/1 220/60/1 220/60/1 220/60/3 220/60/3
m3/h 200 300 400 500 800 1000 1500 2000
Air Flow
cfm 120 175 235 300 470 600 900 1200
Temp. Exchange Efficiency % 65 65 65 65 65 65 65 65
Enthalpy Cooling % 50 50 50 50 50 50 50 50
Exchange Eff.
(Hi Speed) Heating % 55 55 60 60 60 60 60 60

Heat Ex-
"Sound Level dB(A) 27 30 32 35 39 40 51 53
change Mode
(Hi Speed)"
Bypass Mode dB(A) 28 31 33 36 40 41 52 54
Dimensions (W/H/D) mm 866/655/264 944/722/270 944/927/270 1038/1026/270 1286/1006/388 1286/1256/388 1600/1270/540 1650/1470/540
Weight kg 23 26 31 41 62 79 163 182

Notes:
TERV0120 to TERV0600 have three speeds, while models TERV0900 to TERV1200 have one speed
Sound level measured at 1.4m in an anechoic room
Temp. Exchange Efficiency is the average of cooling and heating values

45VRF-SLB005-EN
100% Fresh Air - 4TVF
Flexibility
External static pressure up to 260 Pa

Comfort
Both fresh air filtration and heating or cooling
achieved with the same unit.

Improved Indoor Air Quality.

Efficient air distribution

Standard filter

Layout Example:
Outdoor Units

Indoor Unit Indoor Unit

Outdoor Air processing unit

Air-conditioning Outsideair supply

Wireless Wireless Wired Controller Wired Controller Wired Controller


*Optional Controlers

TCONTRM05B TCONTRM02B TCONTKJR90A TCONTKJR12B TCONTKJR120A


Heat Pump Heat Recovery Heat Pump Heat Pump Heat Recovery

46VRF-SLB005-EN
Fresh Air Units 60 Hz
Model Numbers 4TVF0042B10 4TVF0048B10 4TVF0068B10 4TVF0085B10 4TVF0095B10
Power Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
KW 12.5 14 20 25 28
Cooling
Btu/h 42,650 47,800 68,250 85,300 95,600
Capacity
KW 10.5 12 18 20 22
Heating
Btu/h 35,800 40,950 61,400 68,250 75,000
Power Input W 461 461 1063 1063 1063
Rated Current A 2.3 2.3 5.3 5.3 5.3
Air Flow (H/M/L) m3/h 1568/1452/1352 1568/1452/1352 4429/3884/3332 4560/4083/3563 4939/4405/3859
Indoor External Static Pressure (H) 50(30~ 196) 50(30~ 196) 140(50~260) 140(50~260) 160(50~260)
Sound Pressure (H/M/L) dB(A) 54/52/50 54/52/50 54/53/51 55/54/52 55/54/52
Dimensions (W/H/D) mm 1368/420/691 1368/420/691 1443/470/810 1443/470/810 1443/470/810
Net Weight kg 69.5 69.5 115 115 115
Liquid Side mm 9.52 9.52 9.52 9.52 9.52
Refrigerant Piping
Gas Side mm 15.9 15.9 15.9 15.9 15.9
Drainage Water Pipe (OD) mm 25 25 32 32 32

Fresh Air Units 50 Hz


Model Numbers 4TVF0042BB0 4TVF0048BB0 4TVF0068BB0 4TVF0085BB0 4TVF0095BB0
Power Supply V/Ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
KW 12.5 14 20 25 28
Cooling
Btu/h 42,650 47,800 68,250 85,300 95,600
Capacity
KW 10.5 12 18 20 22
Heating
Btu/h 35,800 40,950 61,400 68,250 75,000
Power Input W 461 461 1063 1063 1063
Rated Current A 2.3 2.3 5.3 5.3 5.3
Air Flow (H/M/L) m3/h 1700/1350/1050 1700/1350/1050 3150/2650/2300 3300/2850/2500 3300/2850/2500
Indoor External Static Pressure (H) 30~220 30~220 50~260 50~260 50~260
Sound Pressure (H/M/L) dB(A) 54/52/50 54/52/50 54/53/51 55/54/52 55/54/52
Dimensions (W/H/D) mm 1368/420/691 1368/420/691 1443/470/810 1443/470/810 1443/470/810
Net Weight kg 69.5 69.5 115 115 115
Liquid Side mm 9.52 9.52 9.52 9.52 9.52
Refrigerant Piping
Gas Side mm 15.9 15.9 15.9 15.9 15.9
Drainage Water Pipe (OD) mm 25 25 32 32 32

* Nominal cooling capacities are based on the following conditions: return air temperature: 27 CDB, 19 CWB, outdoor temperature: 35 CDB, equivalent ref. piping: 8 m (horizontal)
* Nominal heating capacities are based on the following conditions: return air temperature: 20 CDB, outdoor temperature: 7 CDB, 6 CWB, equivalent ref. piping: 8 m (horizontal)
* Capacities are net, not including a deduction for cooling (an addition for heating) for indoor fan motor heat
* The operating sound has been measured in a semi anechoic chamber. The microphone was located 1.4 m below the unit.
With actual installation, the indication value normally differs widely according to the surrounding noise and reverberations.

Note: Specifications subject to change without notice.

47VRF-SLB005-EN
Ingersoll Rand (NYSE:IR) is a world leader in creating and sustaining safe, comfortable and efficient environments in commercial, residential and
industrial markets. Our people and our family of brandsincluding Club Car, Ingersoll Rand, Schlage, Thermo King and Tranework together to
enhance the quality and comfort of air in homes and buildings, transport and protect food and perishables, secure homes and commercial properties,
and increase industrial productivity and efficiency. We are a $14 billion global business committed to sustainable business practices within our
company and for our customers. For more information, visit www.ingersollrand.com.

2012 Trane All rights reserved We are committed to using environmentally trane.com
VRF-SLB005-EN February 1, 2013 conscious print practices that reduce waste. ingersollrand.com