Vous êtes sur la page 1sur 5

MT-8195-2006

Neonatal Transport System TI500 Globe-Trotter IC


High performance
thermoregulation & respiratory care

A fully-featured neonatal transport incubator.

INTEGRATED CENTER OF EXCELLENCE BATTERY LIFE AND TRANSPORT DURATION The Drger TI500 Globe-Trotter (GT-IC) neonatal
The TI500 Globe-Trotter (GT-IC) is a compact, With a single batterythe standard configuration transport system provides the exceptional safety, care,
integrated transportation system designed to meet the GT-IC can operate for more than 90 minutes. and tranquility needed when transporting high risk,
the needs of the most delicate newborns and their With an optional second battery, it can operate for premature, low birth weight, or critically ill newborns
caregivers. The GT-IC can be used to transport more than 180 minutes. Battery life can be extend- from their point of birth to an appropriate care center.
infants via ground ambulance, medevac HEMS ed simply by recharging from vehicle power during
helicopter, charter fixed-wing aircraft, or passenger transport. An on-board battery indicator enables By seamlessly integrating a broad suite of state-of-the-
airliner services. monitoring of remaining charge. art medical technologies in a compact and ergonomic
form factor, the GT-IC provides an easy-to-operate,
Extending the technology of the bestselling TI500 GT-IC batteries can also be changed-out in less easy-to-transport, and easy-to-maintain neonatal
Transport Incubator, the GT-IC offers exceptional than two minutes, with no special tools. This en-
thermoregulation and ventilation with an integrated sures that you can use each GT-IC unit on multiple intro page image
transport system that enables you to deliver the best
possible care to your most delicate infants.
air compressor and humidification system. It transport missions each day, even when there is
also offers options for vital signs monitoring and insufficient time to recharge the batteries fully
pulse oximetry. between or during missions.

AIR COMPRESSOR OBVIATES NEED FOR AIR CYLINDERS THERMOREGULATION EXCELLENCE WITH DOUBLE WALLS
The GT-IC includes an integrated air compressor The GT-IC offers closed-loop air temperature con-
and filter that supply air in continuous quantities trol systems to maintain temperature stability within
(contingent on battery life) that can help extend a very narrow range to create the thermally neutral
the maximum duration (and range) of any transport environment required by fragile infants. A double-
mission. The GT-IC is the only transport incubator walled hood of substantial thickness and strength
system globally that offers this capability. ensures superior heat retention, effective noise
resistance, and high durability to withstand any
INTEGRATED HUMIDIFICATION rough-handling in-and-out of vehicles. Better heat
An active humidification system delivers heated, hu- retention reduces drain on incubator batteries and
midified, and blended gas into the patient breath- extends the maximum duration (and range) of any
MT-8240-2006

ing circuit. The gas is electrically warmed along the transport mission that might rely on batteries alone.
length of the circuit.

Additionally an integral passive humidity pad helps


humidify the entire infant compartment (cabin).
By maintaining relative humidity at 50% to 70% for
up to 12 hours, the GT-IC can help minimize the
infants evaporative heat loss.
Working together, these active and passive humidi-
fication modes are particularly beneficial for babies
of less than 26 weeks gestational age.
Designed for
safety & access

4
USER-FRIENDLY DESIGN AIRWORTHINESS STANDARDS COMPLIANCE
The GT-IC includes internal gas storage, slide-out 2 5 The TI-500 complies with airworthiness stan-
mattress tray, auxiliary flow meter, front-mounted dards RTCA/DO-160D, EN 13718-1:2008, and
4 3
controls, integrated drawer, and input voltages EN1789:2007 for vibration, shock, crash safety,
and cords as highlighted below. 6 1 water-proofness, humidity, temperature, altitude and
electromagnetic compatibility (EMC).
1. Internal Gas Storage
Gas cylinders reside beneath the incubator TOTAL COST OF OWNERSHIP
in the GT-IC, making them easy to transport. Gas Together, the high reliability, durability, and sturdi-
cylinders can also be changed quickly, without any ness of design of the GT-IC, contribute to its low
special tools. total cost of ownership (TCO). In particular, the
integral TI-500 incubator has few parts to disas-
2. Slide-Out Mattress Tray semble, making it very easy to clean and maintain.
With a head-end access panel and slide-out mat- The device design includes many smooth, curved,
tress tray, the GT-IC enables easy and quick intuba- and rounded surfaces to prevent bacteria coloniza-
tion of the baby as needed. tion in corners and to facilitate thorough cleaning.

3. Auxiliary Flow Meter FUTURE-PROOFING


An auxiliary flow meter is standard on the GT-IC, Drger has been a leader in the fields of medical
with an additional hand circuit to allow manual and safety technologies for more than 120 years.
resuscitation if necessary. This offers the ability to Our reputation for delivering service, support,
ventilate twins in one incubator. spare parts, and training to customers around the
world is well-earned. Our financial strength, global
4. Front-Mounted Controls scope, and technical depth will ensure that your
Front-mounted controls and gauges, for all aspects equipment remains up-and-running for many years.
of the GT-IC, make it easy to keep a watchful eye
on all the infants vital parameters.

5. Integrated Drawer
The integrated drawer secures medical records,
drugs, or other small articles that must be trans-
ported with the infant.

6. Input Voltages and Cords


The GT-IC accepts a wide range of input voltages
(line AC, 12 or 28 VDC, or battery power), ensur-
ing its compatibility across different air and ground
transport systems. A single power cord and strip
eliminate cable clutter while providing a place to
plug in multiple electronic accessories.
TECHNICAL SPECIFICATIONS DRAGER TI500 GLOBE-TROTTER IC

Physical Attributes NeoSID Nova Plus (Vital Signs Monitor)


Height 22.5 in (57.2 cm) Built-in Masimo SET technology
Length 51 in (129.5 cm) Parameters Heart rate
Width 22.5 in (56.5 cm) Respiratory rate
Weight 204 lbs (92.5 kg)* Pulse rate
Oxygen saturation
Built-in Drawer Graphic ECG
Volume 238 cubic inches Respiration
Plethysmogram
Electrical Specifications Breathing rate 2 to 120 breaths per minute (bpm)
AC Power requirements 110/120 V, 50/60/400 Hz Apnea alarm timer Adjustable from 5 to 30 sec
220/240 V, 50/60/400 Hz Heart rate 10 to 250 beats/min measurement range
DC (incubator only) 12 V or 28 V 20 to 240 beats/min adjustable alarm range monitoring done by either
Chassis leakage current 120 V < 300 A + 10% the lead ECG or pulse timer of the SPO2 measurement
220 V < 500 A + 10% SPO2 measurement and alarms 0 to 100% measurement range
4 AC outlets Refresh time of waveform display (x-axis) 5 seconds
AC and incubator DC cable included
Trend and Event Viewing, Storage and Alarms
Ventilator Battery Specifications Viewability Directly on the NeoSID Nova plus monitor and with NeoView-Net
Type Rechargeable, 12 V DC, 17 AH Sealed gel-type battery software on a PC
Battery Run Time 1.5 hours with humidifier heating, 3 hours without heating Downloadable to PC Via RS-232 serial interface port;
Life Expectancy 200 complete charge/discharge cycles minimum NeoView-Net software for PC Enables data graphing, assessing, tabularizing, documenting on PC
Charge Time 24 hours from full discharge Trend storage 18 days long-term trend (measurement value every 3 min)12 hours
short-term trend (measurement value every 6 second)
Forms of Ventilation Event storage 30 s, 186 events
IMV Intermittent mandatory ventilation; Combination of spontaneous respiration 60 s, 96 events
and machine ventilation 90 s, 62 events
CPAP Spontaneous respiration with continuous positive airway pressure 120 s, 31 events
Manual ventilation Enables hand-bagging Immediate visual and auditory alarms When values fall short of or exceed adjustable critical threshold levels.
Note: Mixing of air and oxygen allows for setting of desired oxygen When alarms are triggered, physiological parameters and curves before,
concentration (FiO2) using double flowmeters during, and after the event are archived

Ventilation Parameters NeoSID Nova Pulse Oximeter
Inspiration time Adjustable from 0.25 to 2 s Parameters Pulse rate
Expiration time Adjustable from 0.25 to 30 s Oxygen saturation
O2 flow Adjustable from 0 to 10 liters/min Graphic Plethysmogram
AIR flow Adjustable from 0 to 10 liters/min Curve Representation Event list
Oxygen concentration Adjustable from 21 to 100% O2 Short-term trend
Positive end expiratory pressure (PEEP) Adjustable from 0 to 10 cmH2O Long-term trend
Inspiratory ventilation pressure (PIP, pressure plateau) Adjustable from 15 to 60 cmH2O
Suction Pump (Atmoport N)
Oxygen Monitor Air flow rate 36 +/- 2 liters/min
Digital display 20 to 99% O2 of the ventilation gas Vacuum scale range 0 to -750 mmHG
Upper O2 limit Adjustable from 20 to 99% O2, visible and auditory alarm for high level Collection jar 1 liter plastic
Lower O2 limit Adjustable from 20 to 99% O2, visible and auditory alarm for low level Operating time with battery 45 min approximately
Optional manual calibration Performed by a clinician Charging time of rechargeable battery 2 hours with 12 VDC

Other Monitoring * Weight includes one battery
Ventilation pressure gauge -10 to 60 cmH2O ** Ventilator has test mode to check that fields illuminate and avoid alarm sound.
Breathing rate for IMV (digital) 2 to 120 breaths per minute (bpm)

Active Humidity and Heated Breathing Circuit
Total hose length 1200 mm
Heated portion 800 mm
Patient gas temperature 35 to 37 C, dependent on ambient temperature
Relative humidity 80 to 98%

90 66 508 | 05.10 | Marketing Communications DMI |Printed in United States | Chlorine-free environmentally compatible | Subject to modifications | 2010 Drgerwerk AG & Co. KGaA
CORPORATE HEADQUARTERS
Drgerwerk AG & Co. KGaA
Moislinger Allee 5355
23558 Lbeck, Germany

www.draeger.com

Manufacturer: INDONESIA INDONESIA Sales Office REGION ASIA / PACIFIC


Drgerwerk AG & Co. KGaA PT. Draeger Medical Indonesia PT. Draeger Medical Indonesia Draeger Medical
Moislinger Allee 5355 Menara Standard Chartered Lt. 30 Beverly Antasari

Building South East Asia Pte Ltd.
23558 Lbeck, Germany Jl. Prof. Dr. Satrio No. 164 Jl. Pangeran Antasari
No. 67 fhjal L 25 International Business Park
Karet Semanggi, Setiabudi Cilandak
Barat #04-27/29 German Centre
Jakarta Selatan Jakarta Selatan Singapore 609916, Singapore
12930 Indonesia 12430 Indonesia Tel +65 6572 4388
Locate your Regional Sales Tel +62 21 7664 105 Tel +62 21 7664 105 Fax +65 6572 4399
Representative at: Fax +62 21 7591 5739 Fax +62 21 7591 5739 asia.pacific@draeger.com
www.draeger.com/contact

Vous aimerez peut-être aussi