Académique Documents
Professionnel Documents
Culture Documents
PMF / GMF
General description:
Reciprocating pump PMF / GMF EUGEN WOERNER GmbH & Co. KG Leaflet-No. 9002.10.07 EN
110.000 Postfach 1661 DE-97866 Wertheim Replaces No. 9002.05.07 EN
Am Eichamt 8 DE-97877 Wertheim Page 1 of 10
Tel. +49 (0) 9342 803-0 info@woerner.de
Fax.+49 (0) 9342 803-202 www.woerner.de
Mode of operation:
- Subject to modifications -
surface, thus enabling precise level
monitoring. If there is no level monitoring
5 provided for, a stripper 4 is installed.
7 2
When fitting another pump element into the Reciprocating pumps must be operated
reciprocating pump, please proceed as with clean oil or grease from original drums
shown in the sketch beside: With the only. If, upon start-up, filling is not made via
delivery piston being approximately pulled the filling nipple, the pump, in case of initial
out half, insert the pump element diagonally filling, has to be filled with gear oil up to the
upward into the casing's reception hole. stirrer wing's level. This way, proper
Insertion and operation will be easier when deaeration is ensured. The lubricant leads
the hole that serves to accommodate the must be cleaned and have no obstructions.
delivery piston is filled with grease. Do not They shall not be con-nected with the
put the pump element into horizontal lubrication points, unless lubricant comes
position and screw in, unless the delivery out free of bubbles. All delivery pipe
piston's head touches the pressure ring and connections should be checked for
ratches into the latter's groove. leakage.
When demounting, pull the pump element
cautiously out of the casing such that the
delivery piston will remain within the pump
element.
Suction stroke
Delivery volume
- Subject to modifications -
5
2
6 1
Pressure stroke
Suction stroke is accomplished by delivery hole 3 and the lubricant is delivered through Six latches equal one rotation of the
piston 1 and control piston 2. In this the delivery piston to the outlet. The pump adjustment nipple and a reduction of the
process, delivery piston 1 is actuated by the elements are delivered with maximum nominal delivery volume by 33%. 14 latches
eccentric shaft, whilst the spring actuates delivery volume, i.e. they are set to full (minimum) equal a delivery volume
control piston 2. The control piston closes stroke. reduction down to 25% of the nominal
pressure hole 3 and is kept in a certain The delivery volume can be adjusted delivery volume.
position as determined by the preset continuously between 25 and 100% of the The element having a piston diameter of
delivery volume. The delivery piston moves nominal delivery volume. After having 8 mm = 0,15 cm³/stroke is marked with a
on, causing a vacuum to be built up in the removed lock screw 7, the stroke is to be red ring "R".
proportioning space. When the delivery changed by means of the enclosed spanner
piston has opened suction hole 4, lubricant through adjustment nipple 6. When turning
starts to be sucked from the reservoir. the nippe to the right, delivery volume will
decrease. At the adjustment nipple, there is
In case of pressure stroke, delivery piston a hexagon against which a spring loaded
1 moves to the left. In this motion, suction piston is pressing radially. Thus, any
hole 4 is closed and control piston 2 independent change of the delivery volume
displaced by virtue of the lubricant being will be prevented. At the same time, the
available in between the delivery and latching serves as a measure for setting the
control pistons until it releases pressure delivery volume.
Number of
Type
mountable elements
GMF-A
for M8 for M8 at maximum 2
PMF-A
2
1
3 GMF-B
at maximum 10
4 PMF-B
GMF-C
5 at maximum 20
1 PMF-C
GMF-D
- Subject to modifications -
6
at maximum 24
PMF-D
7
8
2 10 9 General technical data:
10 20
8 21
10 20
8 Material:
9 19 9 19
Casing: Aluminium
Pump element: Steel, galvanised
Reservoir 2, 4, 7, 25l: Steel,
galvanised
Reservoir 5, 10, 30l: Polyester
Gaskets: NBR
- Subject to modifications -
Drive "M": with gear and motor Motor electrical data: Drive "L": with gear and hydraulic
BG63 motor
Drive "N": with gear and motor Mains voltage: 230 / 400 V
BG71 Weight [kg]: 7,7 + reservoir weight+
Frequency: 50 Hz
0,25 x number of elements
Special voltage and frequency possible
Weight [kg]: 10,7 + reservoir weight+
0,25 x number of elements Synchronous speed: 1500 min
-1
Overall reduction same as with drives
"M", "N"
The gears are filled with 80 cm³ ISO VG 220 Power:
gear oil. After 3000 hours of operation, Drive "M": 0,18 kW
checking is required. Drive "N": 0,37 kW
Protection system: IP55 Motor technical data:
Thermal category: F When oil flow is 3,5 l/min
Power: 0,25 kW
-1
Speed: 400 min
-1
Delivery flow max. operating pressure [bar] (with 20 elements installed) Speed max.: 1950 min
Overall per element [cm³/min]
transmission Drive "M" Drive "N" Pressure inclination max.: 100 bar
Element Ø6 Element Ø8 Element Ø6 Element Ø8 Element Ø6 Element Ø8
60 : 1 1,82 3,4 230 100 200 Oil flow max.: 16 l/min
97 : 1 1,12 2,1 330 170 mind permissible element stroke
160 : 1 0,67 1,28 270 number!
316 : 1 0,34 0,64 320 350
350 The gears are filled with 80 cm³ ISO VG 220
625 : 1 0,17 0,32 350
1250 : 1 0,087 0,163 350 gear oil. After 3000 hours of operation,
2500 : 1 * 0,0435 0,0815 checking is required.
* on request only
3
1 2
- Subject to modifications -
Drive "V": with gear Drive "O": oscillating Drive "R": long driving shaft 1
Drive "U": short driving shaft 2
Drive "K": for coupling of 2 PMF
driving shaft 2 and 3
Weight [kg]: 6,4 + reservoir weight+ Weight [kg]: 6,8 + reservoir weight+
0,25 x number of elements 0,25 x number of elements Weight [kg]: 5,2 + reservoir weight+
0,25 x number of elements
The gears are filled with 80 cm³ ISO VG 220 Formula for eccentric stroke
gear oil. After 3000 hours of operation, calculation: 2 x L x p x n1 x i
h=
checking is required. n
Connection diagram:
- Subject to modifications -
black grey
Float on bottom orange red full
(empty reservoir) blue brown
reservoir
black grey
orange red
blue brown
Follow-up piston
atop
(full reservoir)
Filling connector:
Purchase-no. Depiction Mounting place Use
Filling nipple
Tube Æ 12
Instead of a
- Subject to modifications -
(U 30) "B"
pump element
110.550-66
Manometer connector:
Adjustment spanner:
Purchase-no. Depiction Use
internal
- Subject to modifications -
N
GMF-B PMF-B 0 ¸ 10 0 ¸ 10 0 ¸ 10 0 ¸ 10 0 ¸ 10 0 ¸ 10 0 ¸ 10 Grease K
see
(10 places) (10 places) 4 L 1444444442444444443 at max. 10 with level
switch and
together 10 elements possible at maximum!
with follow-up
10 O B piston
Number Number Number Number Number Number
GMF-C PMF-C 7 K 0 ¸ 20 0 ¸ 20 0 ¸ 20 0 ¸ 20 0 ¸ 20 0 ¸ 20 Grease F
0 ¸ 20
table with follow-
(20 places) (20 places) R 1444444442444444443 at max. 20 up piston,
together 20 elements possible at maximum! with without
30 V level switch
25 U
Number Number Number Number Number Number
GMF-D PMF-D 0 ¸ 24 0 ¸ 24 0 ¸ 24 0 ¸ 24 0 ¸ 24 0 ¸ 24
Oil S
P 0 ¸ 24
with level
(24 places) (24 places) 1444444442444444443 at max. 24 switch without
follow-up
together 24 elements possible at maximum! piston
316 4,25
5) Level monitoring "K" and "F" possible in case of polyester reservoirs only!
625 7,66
1250 12,7
2500 25
3300 50
4356 66
Purchase-example:
Pump PMF-B, reservoir 10l, overall reduction 1,33 (acc. to table), drive type U, 5 pieces of element 6 with pipe connector 8, 2 pieces of
element 8 with pipe connector 6, filling connector V, 2 lock screws, level monitoring "S".
Purchase-designation:
PMF-B.B / 10 / 1,33 / U / 0 / 5 / 0 / 2 / 0 / 0 / V / 2 / S