JOB REF: D2010

PROJECT: Building REVISION: A

PART OF STRUCTURE: WIND LOADS ACTING ON STRUCTURE CALC. BY: A.A


DRAWING REFERENCE: - DESIGN CODE ASCE7-05 CHECK. BY: A.A

WIND LOADS ACTING ON THE STRUCTURE BASED ON ASCE 7-05


6.5 METHOD 2- ANALYTICAL PROCEDURE
Applicable since the building satisfies the two conditions set forth in Sec. 6.5.1: (ASCE 7-05, 6.2)
1. The building is regular in shape

2. The building does not have response characteristics making it subject to across wind loading, vortex shedding, instability due to galloping or flutter; or
does not have a site location for which channeling effects or buffeting in the wake of upwind obstructions warrant special consideration.

6.5.12. Design Wind Loads on Enclosed and Partially Enclosed Buildings. (all Heights) roof

z = 45.14 m Height above local ground level


No. = 12 number of stories

windward

leeward
qz = (0.613 v) Kz Kzt Kd I Velocity pressure where, 0.613=1/5 Air density v z (ASCE 7-05, 6.5.10)

v = 45 m/sec Basic wind speed (3 sec gust) = 100.6621 mph


local Gr. Level
Terrain category:
Exposure B Exposure C Exposure D

ASCE 7-05, Table(6-4)


Structure Type Kd

Trussed Towers 0.85


Triangular, square, rectangular 0.95
All other cross sections

Kd = 0.85 Directionality factor (ASCE 7-05, 6.5.4.4)

Occupancy category of buildings and other structures for wind loads


ASCE 7-05, Table (1-1)
Nature of Occupancy

Buildings and other structures containing highly toxic substances shall be eligible for classification as Occupancy Category II structures if
it can be demonstrated to the satisfaction of the authority having jurisdiction by a hazard assessment as described in Section 1.5.2 that a
release of the highly toxic substances does not pose a threat to the public. This reduced classification shall not be permitted if the buildings
or other structures also function as essential facilities.

365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A

PART OF STRUCTURE: WIND LOADS ACTING ON STRUCTURE CALC. BY: A.A


DRAWING REFERENCE: - DESIGN CODE ASCE7-05 CHECK. BY: A.A

*Cogeneration power plants that do not supply power on the national grid shall be designated Occupancy Category II.

Occupancy Category: III


Region Non-Hurricane Prone Regions

I = #N/A Importance factor (ASCE 7-05, 6.5.5, Table [6-4])

ASCE 7-05, Table (6-2)


Exposure a zg a^ b^ a- b- c l e zmin*
1 B 7.0 365.76 117.0 0.84 114.0 0.45 0.30 97.54 113 9.14
2 C 9.5 274.32 119.5 1.00 116.5 0.65 0.20 152.40 115 4.57
3 D 11.5 213.36 1111.5 1.07 119.0 0.80 0.15 198.12 118 2.13
*zmin = minimum height used to ensure that the equivalent height z is greater of 0.6h or z min.
For buildings with h 5 zmin, z shall be taken as zmin

a = 7.0
zg = 365.76 m
Kz = 2.01(z/zg) 2/a
Velocity exposure (see the following tables) (ASCE 7-05, 6.5.6.6, Table [6-3])
Kz min = 2.01(4.572/zg)2/a (metric units) x

Local ground H/2 H

Lh

Hill shape 2-dimensional escarpments Direction Upwind of Crest

365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A

PART OF STRUCTURE: WIND LOADS ACTING ON STRUCTURE CALC. BY: A.A


DRAWING REFERENCE: - DESIGN CODE ASCE7-05 CHECK. BY: A.A
2-dimensional escarpments Upwind of Crest

H = 0 m Height of Hill
Lh = 13000 m Distance upwind of crest to where the difference in ground elevation is half the height of hill
H/Lh = 0.00
x = 500 m Distance from the crest to the building
K1/(H/Lh) = 0.75
K1 = 0.00
Lh = 13000 m
m = 1.50
K2 = 0.97 1 - x/mLh
g = 2.50
K3 = 0.99 e-gz/Lh
Kzt = 1.00 [1+K1K2K3]2 Topographic factor (ASCE 7-05, 6.5.7, Figure [6-4])

G = 0.85 Gust effect factor


Enclosure classification Enclosed Building

GCpi = 0.18 Internal Pressure Coefficient, GCpi (ASCE 7-05, 6.5.9, Figure [6-5])
Cp = 0.80 Windward wall (ASCE 7-05, 6.11.2, Figure [6-6])
Cp = -0.50 Leeward wall (ASCE 7-05, 6.11.2, Figure [6-6])
Cp = -0.70 Side wall (ASCE 7-05, 6.11.2, Figure [6-6])
Cp = variable as shown Roof (ASCE 7-05, 6.11.2, Figure [6-6])

-0.70
-0.90
-0.50 -0.30

0.80 Plan -0.50


0.80 Elevation -0.50

-0.70

P = qGCp-qi(GCpi) (ASCE 7-05, 6.5.12)


q = qz For windward walls, evaluated at height z from the ground
= qh For leeward walls, side walls, and roofs, evaluated at height h
qi = qh For windward walls, side walls, leeward walls, and roofs of enclosed buildings

365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A

PART OF STRUCTURE: WIND LOADS ACTING ON STRUCTURE CALC. BY: A.A


DRAWING REFERENCE: - DESIGN CODE ASCE7-05 CHECK. BY: A.A

WIND LOADS ACTING ON THE STRUCTURE BASED ON ASCE 7-05


Output velocity pressures
z v Kd I Kzt Kz qz
0 45 0.85 1.15 1 0.57472 697.3621
4.88 45 0.85 1.15 1 0.585525 710.4736
8.54 45 0.85 1.15 1 0.687045 833.6569
12.2 45 0.85 1.15 1 0.760751 923.0922
15.86 45 0.85 1.15 1 0.81997 994.9479
19.52 45 0.85 1.15 1 0.870087 1055.76
23.18 45 0.85 1.15 1 0.913875 1108.891
26.84 45 0.85 1.15 1 0.952967 1156.326
30.5 45 0.85 1.15 1 0.988416 1199.34
34.16 45 0.85 1.15 1 1.020945 1238.809
37.82 45 0.85 1.15 1 1.051071 1275.364
41.48 45 0.85 1.15 1 1.07918 1309.472
45.14 45 0.85 1.15 1 1.10557 1341.493
###

365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A

PART OF STRUCTURE: WIND LOADS ACTING ON STRUCTURE CALC. BY: A.A


DRAWING REFERENCE: - DESIGN CODE ASCE7-05 CHECK. BY: A.A

WIND LOADS ACTING ON THE STRUCTURE BASED ON ASCE 7-05


Output combined pressures
External pressure Internal pressure Combined pressure
Location z
qz Cp G qzGCp qi GCpi qiGCpi qzGCp+qiGCpi qzGCp-qiGCpi

Leeward All 1341.49 -0.5 0.85 -570.13 1341.49 0.18 241.47 -328.67 -811.60
Side walls All 1341.49 -0.7 0.85 -798.19 1341.49 0.18 241.47 -556.72 -1039.66
Roof 45.14 1341.49 -0.9 0.85 -1026.24 1341.49 0.18 241.47 -784.77 -1267.71
0 697.36 0.8 0.85 474.21 1341.49 0.18 241.47 715.67 232.74
4.88 710.47 0.8 0.85 483.12 1341.49 0.18 241.47 724.59 241.65
8.54 833.66 0.8 0.85 566.89 1341.49 0.18 241.47 808.36 325.42
12.2 923.09 0.8 0.85 627.70 1341.49 0.18 241.47 869.17 386.23
15.86 994.95 0.8 0.85 676.56 1341.49 0.18 241.47 918.03 435.10
19.52 1055.76 0.8 0.85 717.92 1341.49 0.18 241.47 959.39 476.45
23.18 1108.89 0.8 0.85 754.05 1341.49 0.18 241.47 995.51 512.58
26.84 1156.33 0.8 0.85 786.30 1341.49 0.18 241.47 1027.77 544.83
30.5 1199.34 0.8 0.85 815.55 1341.49 0.18 241.47 1057.02 574.08
34.16 1238.81 0.8 0.85 842.39 1341.49 0.18 241.47 1083.86 600.92
37.82 1275.36 0.8 0.85 867.25 1341.49 0.18 241.47 1108.72 625.78
41.48 1309.47 0.8 0.85 890.44 1341.49 0.18 241.47 1131.91 648.97
45.14 1341.49 0.8 0.85 912.22 1341.49 0.18 241.47 1153.68 670.75
### 0 0 0

365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A

PART OF STRUCTURE: WIND LOADS ACTING ON STRUCTURE CALC. BY: A.A


DRAWING REFERENCE: - DESIGN CODE ASCE7-05 CHECK. BY: A.A

WIND LOADS ACTING ON THE STRUCTURE BASED ON ASCE 7-05


Design wind loads
Windward face Leeward face Combined
Tributary Building
z design wind
height width Design wind pressure Design wind force (kN) Design wind pressure Design wind force (kN) force (kN)

4.88 4.88 56.1 715.67 195.93 -328.67 -89.98 285.91


8.54 3.66 56.1 724.59 148.78 -328.67 -67.48 216.26
12.2 3.66 56.1 808.36 165.98 -328.67 -67.48 233.46
15.86 3.66 56.1 869.17 178.46 -328.67 -67.48 245.95
19.52 3.66 56.1 918.03 188.50 -328.67 -67.48 255.98
23.18 3.66 56.1 959.39 196.99 -328.67 -67.48 264.47
26.84 3.66 56.1 995.51 204.41 -328.67 -67.48 271.89
30.5 3.66 56.1 1027.77 211.03 -328.67 -67.48 278.51
34.16 3.66 56.1 1057.02 217.03 -328.67 -67.48 284.52
37.82 3.66 56.1 1083.86 222.54 -328.67 -67.48 290.03
41.48 3.66 56.1 1108.72 227.65 -328.67 -67.48 295.13
45.14 3.66 56.1 1131.91 232.41 -328.67 -67.48 299.89
### 4 ### ### ### ### ### ###

365312592.xls
last cell in output velocity pressure to be deleted
Cp not calculated as per the figures
Gust factor not calculated exactly