2. The building does not have response characteristics making it subject to across wind loading, vortex shedding, instability due to galloping or flutter; or
does not have a site location for which channeling effects or buffeting in the wake of upwind obstructions warrant special consideration.
6.5.12. Design Wind Loads on Enclosed and Partially Enclosed Buildings. (all Heights) roof
windward
leeward
qz = (0.613 v) Kz Kzt Kd I Velocity pressure where, 0.613=1/5 Air density v z (ASCE 7-05, 6.5.10)
Buildings and other structures containing highly toxic substances shall be eligible for classification as Occupancy Category II structures if
it can be demonstrated to the satisfaction of the authority having jurisdiction by a hazard assessment as described in Section 1.5.2 that a
release of the highly toxic substances does not pose a threat to the public. This reduced classification shall not be permitted if the buildings
or other structures also function as essential facilities.
365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A
*Cogeneration power plants that do not supply power on the national grid shall be designated Occupancy Category II.
a = 7.0
zg = 365.76 m
Kz = 2.01(z/zg) 2/a
Velocity exposure (see the following tables) (ASCE 7-05, 6.5.6.6, Table [6-3])
Kz min = 2.01(4.572/zg)2/a (metric units) x
Lh
365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A
H = 0 m Height of Hill
Lh = 13000 m Distance upwind of crest to where the difference in ground elevation is half the height of hill
H/Lh = 0.00
x = 500 m Distance from the crest to the building
K1/(H/Lh) = 0.75
K1 = 0.00
Lh = 13000 m
m = 1.50
K2 = 0.97 1 - x/mLh
g = 2.50
K3 = 0.99 e-gz/Lh
Kzt = 1.00 [1+K1K2K3]2 Topographic factor (ASCE 7-05, 6.5.7, Figure [6-4])
GCpi = 0.18 Internal Pressure Coefficient, GCpi (ASCE 7-05, 6.5.9, Figure [6-5])
Cp = 0.80 Windward wall (ASCE 7-05, 6.11.2, Figure [6-6])
Cp = -0.50 Leeward wall (ASCE 7-05, 6.11.2, Figure [6-6])
Cp = -0.70 Side wall (ASCE 7-05, 6.11.2, Figure [6-6])
Cp = variable as shown Roof (ASCE 7-05, 6.11.2, Figure [6-6])
-0.70
-0.90
-0.50 -0.30
-0.70
365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A
365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A
Leeward All 1341.49 -0.5 0.85 -570.13 1341.49 0.18 241.47 -328.67 -811.60
Side walls All 1341.49 -0.7 0.85 -798.19 1341.49 0.18 241.47 -556.72 -1039.66
Roof 45.14 1341.49 -0.9 0.85 -1026.24 1341.49 0.18 241.47 -784.77 -1267.71
0 697.36 0.8 0.85 474.21 1341.49 0.18 241.47 715.67 232.74
4.88 710.47 0.8 0.85 483.12 1341.49 0.18 241.47 724.59 241.65
8.54 833.66 0.8 0.85 566.89 1341.49 0.18 241.47 808.36 325.42
12.2 923.09 0.8 0.85 627.70 1341.49 0.18 241.47 869.17 386.23
15.86 994.95 0.8 0.85 676.56 1341.49 0.18 241.47 918.03 435.10
19.52 1055.76 0.8 0.85 717.92 1341.49 0.18 241.47 959.39 476.45
23.18 1108.89 0.8 0.85 754.05 1341.49 0.18 241.47 995.51 512.58
26.84 1156.33 0.8 0.85 786.30 1341.49 0.18 241.47 1027.77 544.83
30.5 1199.34 0.8 0.85 815.55 1341.49 0.18 241.47 1057.02 574.08
34.16 1238.81 0.8 0.85 842.39 1341.49 0.18 241.47 1083.86 600.92
37.82 1275.36 0.8 0.85 867.25 1341.49 0.18 241.47 1108.72 625.78
41.48 1309.47 0.8 0.85 890.44 1341.49 0.18 241.47 1131.91 648.97
45.14 1341.49 0.8 0.85 912.22 1341.49 0.18 241.47 1153.68 670.75
### 0 0 0
365312592.xls
JOB REF: D2010
PROJECT: Building REVISION: A
365312592.xls
last cell in output velocity pressure to be deleted
Cp not calculated as per the figures
Gust factor not calculated exactly