Polarisation Rectifier
POLARISATION RECTIFIER
1i017 Polarisation Rectfir - Mass-Tech Controls Pvt Li
Chemical Processes often have large power rectifiers as their primary source of DC Power. I these rectifiers are tured off, either for maintenance or
a malfunction, there is a danger tothe hardware ofthe chemical process.
To solve this problem, standby rectifiers ar installed in parallel with the main rectifier. These rectifiers, known as Polarisation Rectifiers, pass electric
current through the process and prevent damage. As these rectifiers are used as stand by, they have to be extremely reliable,
During tart up ofthe electrolyser, as the main rectifier is off, the PR supplies current to the electrlyser, and continues to supply the current as long
as the output voltage ofthe main rectifiers less than the voltage of PR. The moment the main rectifier voltage Is equal tothe PR, the PR supplies
current equal to or less than the setpoint current.
‘During normal operation this unit operates in parallel withthe main rectifer supplying rated current each polarisation rectifier consists of 2 rectifiers
\which are designed to operate in parallel cedundant made, A third rectiier known as the Booster rectifler may also be used,
‘Normally both paralleled reciers supply 0¥ ofthe output current n case of allure of one of the rectifers, the healthy unt supplies 100% current
to the Electrolyser without any interruption.
‘The Booster polarisation rectifier is connected between the postive and negative end of predetermined set of elements
“The PRs designed to operate is constant current mode and the currents adjustable manually
“The PR has various protections lke surge protection, fast acting semiconductor fuses, DC overload, DC over voltage, short circuit protection and AC
‘under voltage and also fast acting current limiting which protects the PR from supplying current higher than the set value
With buiin power factor correction circuitry, the PF is better than 0.95 Lag, Efficiency i greater than 85-0%. Output voltage setting is possible from
040 100%, regulation ie better than 1% and ripple <1%,
Different configurations ike 6 pulse oF 12 pulse thyristor bridge switching results in reduced harmonics and ripple.
-Masstech also offers SMP based modular configuration where n¥1 redundancy makes the system more economical, Also Power factor> 0.953 is
achieved without power factor correction ciculry and efficiency fs better than 90%.
FEATURES
+ Auto / Manual
+ Ousput short circu proof
+ Liberal Design margin
+ In build power factor correction and harmonic ter
+ ACinput averioad protection
‘+ Modular Concept, Hot Swappable
RATING
= 50W/3008
+ 220V/50A 0¢, 220V/75A0C
+ 420V/60A 0¢, 420/75A0€
+ souvr7sa oc
‘+ 630V/S0A, 63011708, 6300/2258 DC