Vous êtes sur la page 1sur 1

NOTES:

1. PROTECTION AS PER TYPE 1 WILL BE APPLIED FOR STANDARD WADI


CROSSINGS.
2. PROTECTION AS PER TYPE 2 WILL ONLY BE EXECUTED FOR MINOR
WADI CROSSINGS WITH A WEAK SCOURING TENDENCY.
3. PROTECTION AS PER TYPE 3 WILL BE APPLIED FOR WADI CROSSINGS
MAJOR WADI CROSSING WHERE WADI LEVEL MUST BE RAISED DUE TO THE PIPE GEOMETRY,
UPSTREAM OF THE CROSSING THE WADI BED WILL BE BACKFILLED WITH
IN-SITU MATERIAL AND THE NEW WADI BED WILL BE ELEVATED.
4. MINIMUM COVER ABOVE TOP OF PIPE SHALL BE 2.00 M (PLUS

LONGITUDINAL SECTION SECTION A - A SCOURING DEPTH).


5. BOULDERS, ROCK BUNDS AND CHECK DAMS MUST BE INSTALLED OVER
THE FULL WIDTH OF THE WADI BED AND BANKS.
6. ADEQUATE EROSION PROTECTION SHALL BE PROVIDED, GABION BOXES
AND MATTRESS, BOULDERS, LEAN CONCRETE ENCASEMENT.
A
BOULDERS IN SANDY MATRIX
FLOW DIRECTION
ORIGINAL
WADI BED LEGEND:

GABBIONS GABBIONS
BACKFILL,
MATERIAL IN - SITU TYPE
LEAN CONCRETE

A 0,35
Do.
0,35
FIBRE - OPTIC PIPELINE
SELECTED GRAVEL IN - SITU
MATERIAL, GRAIN SIZE < 50mm
CABLE (CONDUIT)
LEAN CONCRETE, CONDUIT FOR CABL

REFERENCE DRAWINGS
DRAWING No.: DRAWING TITLE:

SECTIONS IN WADI FLOW DIRECTION MINOR WADI CROSSING

WADI CROSSING - Type 1 LONGITUDINAL SECTION


ROCKSHIELD (AS APPROVED) BOULDERS (IN-SITU TYPE) BOULDERS (IN-SITU TYPE)
WATER FLOW OVER FULL WIDTH OF
WARNING TAPE
ORIGINAL FIBRE - OPTIC PIPELINE CABLE (CONDUIT) WADI BED AND BANKS
WADI BED
ORIGINAL WADI BED
WADI BED

ENGINEER'S STAMP CONTRACTOR'S STAMP

4 4 2,5

Do. ROCK BUND


BACK FILL HEAVY BOULDERS OF IN-SITU TYPE
(MATERIAL IN-SITU TYPE) (SEPARATE TRENCH)

ECTED GRAVEL IN-SITU MATERIAL GRAIN SIZE < 50 mm

BACKFILL
1st TRENCH 2nd TRENCH (EXCAVATED MATERIAL)
SELECTED GRAVEL IN-SITU MATERIAL GRAIN SIZE < 50 mm
ROCKSHIELD (AS APPROVED)

WADI CROSSING - Type 2 WADI CROSSING - Type 3


0 Issue for Tender BR Ofner 12.08.2008
ROCKSHIELD (AS APPROVED) BOULDERS (IN-SITU TYPE) ROCKSHIELD (AS APPROVED) BOULDERS (IN-SITU TYPE) B Issue for Draft Tender BR Ofner 25.07.2008
WATER FLOW WATER FLOW WARNING TAPE A Issue for Engineering Report BR HARB 10.12.2007
WARNING TAPE
REV. DESCRIPTION DRAWN CHECKED DATE
ORIGINAL FIBRE - OPTIC PIPELINE CABLE (CONDUIT) ELEVATED FIBRE - OPTIC PIPELINE CABLE (CONDUIT)
WADI BED WADI BED
ORIGINAL CHECK DAM OF HEAVY SALINE WATER CONVERSION CORPORATION
WADI BED BOULDERS (IN-SITU TYPE) KINGDOM OF SAUDI ARABIA

ORIGINAL ORIGINAL
AL LITH
ROCK BUND WADI BED WADI BED WATER TRANSMISSION SYSTEM
2,5 3,5
HEAVY BOULDERS OF IN-SITU TYPE
Do.
(SEPARATE TRENCH)
BACK FILL ILF CONSULTING ENGINEERS
(MATERIAL IN-SITU TYPE) BACK FILL CONSULTING

(MATERIAL IN-SITU TYPE) ROCK BUND ENGINEERS

HEAVY BOULDERS OF IN-SITU TYPE Subconsultant:


ECTED GRAVEL IN-SITU MATERIAL GRAIN SIZE < 50 mm SELECTED GRAVEL IN-SITU MATERIAL GRAIN SIZE < 50 mm (SEPARATE TRENCH)
DRAWING TITLE:

P H S
4 4 2,5 5

Do. TYPICAL WADI CROSSINGS

0m 2m 4m 6m 8m
SCALE 1:100 SCALE: DRAWING SHEET REV.
No.:

--- QP10 - U- 706 - 0