Vous êtes sur la page 1sur 32

MICHAEL KANG

ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com
"
2'-6 Tel: (718) 353-2929
Fax: (718) 661-1619
-0"
13'

-0"
10'

17.
6'

68
'-11
"
41'-10"

62'-5"

'-0"
10

39
'-0"
T.O.S EL. +142'-2"

T.O.S EL. +151'-2"


52'-8"

T.O.S EL. +142'-2"

DN

T.O.S EL. +134'-0"

20
'-0
"
20'-3 1/2"
REV.# DATE DESCRIPTION

KEY PLAN

84'-2"

47
N

'-3
3/4
"
30'-0"

2" 129'-10" 2"

PROJECT

1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

DRAWING INDEX
PLOT PLAN
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:
N

A-001.00
PAGE: 01 OF 32
SYMBOLS LEGEND GENERAL NOTES
INCIDENTAL USE AREAS TABLE 508.2
TITLE 2 FIRE PROTECTION AND SAFETY

1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE NEW YORK CITY BUILDING CODES. ROOM OR AREA REQ'D SEPARATION PROPOSED SEPERATION RATING SECTION 50. ENTRANCE HALLS.
2. CONTRACTOR TO CHECK AND VERIFY ALL CONDITIONS AND DIMENSIONS AT THE SITE BEFORE SECTION 50-B. ENTRANCES: DOOR, LOCKS, INTERCOMMUNICATION SYSTEMS.
ROOMS WITH ANY BOILER 2HR; OR 1HR AND PROVIDE 2HR SECTION 50-C. RIGHT OF TENANTS TO OPERATE AND MAINTAIN A LOBBY ATTENDANT SERVICE
COMMENCING THE WORK. THE ARCHITECT SHALL BE NOTIFIED OF ANY UNUSUAL CONDITIONS. OVER 15PSI
DETAIL TITLE 3. CONTRACTOR IS TO FILE WORKMAN'S COMPENSATION AND TO SECURE ALL PERMITS BEFORE THE
AUTOMATIC FIRE- SECTION 51. SHAFTS, ELEVATORS AND DUMBWAITERS.
X DETAIL SCALE
DETAIL TITLE AND 10 HORSEPOWER EXTINGUISHING SYSTEM SECTION 51-A. PEEPHOLES.
SECTION 51-B. MIRRORS IN CONNECTION WITH SELF- SERVICE ELEVATORS.
MICHAEL KANG
4. THE CONTRACTOR SHALL NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS. IF THERE IS A
PARKING GARAGE 2HR; OR 1HR AND PROVIDE 2HR
DISCREPANCY ON OR LACK OF DIMENSION, THE ARCHITECT SHALL BE NOTIFIED AND THE
(SECTION 406.2) AUTOMATIC FIRE-
SECTION 51-C. RIGHTS OF TENANTS TO INSTALL AND MAINTAIN LOCKS IN CERTAIN ENTRANCE
DOORS.
ARCHITECT, PLLC.
INFORMATION WILL BE PROVIDED SECTION 52. STAIRS. Architectural, Interior Design, Zoning & Building Code Expertise
EXTINGUISHING SYSTEM
DTL NUMBER 5. THE ENGINEER/ ARCHITECT HAS NOT BEEN RETAINED FOR FIELD SUPERVISION OR INSPECTION. ON SECTION 53. FIRE-ESCAPES. 37-01 Main Street, Suite #308, Flushing, NY 11354
LAUNDRY ROOMS OVER 100 S.F, 1HR OR PROVIDE AUTOMATIC 1HR
BEHALF OF THE OWNER TO PERFORM SECTION 54. CELLAR ENTRANCE. michaelkangra@yahoo.com
EXCEPT WITHIN DWELLING FIRE-EXTINGUISHING SECTION 55. WAINSCOTING.
ELEVATION REFERENCE 6. THE CONTRACTOR IS TO RETAIN A LICENSED PROFESSIONAL ENGINEER AS PART OF HIS CONTRACT, UNITS SYSTEM SECTION 56. FRAME BUILDINGS AND EXTENSIONS. Tel: (718) 353-2929
ALL REQUIRED CONTROLLED INSPECTION WORK AS MAY SECTION 57. BELLS; MAIL RECEPTACLES. Fax: (718) 661-1619
DWG NUMBER
7. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO INSURE THE SAFETY AFFECTED BY FIRE-RESISTANCE RATING REQUIREMENT FOR EXTERIOR SECTION 58. INCOMBUSTIBLE MATERIALS.
SECTION 59. BAKERIES AND FAT BOILING.
DTL NUMBER
8. FIVE DAYS PRIOR NOTICE SHALL BE GIVEN TO THE ADJOINING PROPERTY OWNERS AFFECTED BY
WALLS BASED ON FIRE SEPARATION DISTANCE SECTION 60. MOTOR VEHICLES STORAGE
SECTION 61. BUSINESS USE.
9. THERE ARE NO STRUCTURAL CHANGES TO BE MADE UNDER THIS APPLICATION. TABLE 602
10. DRAPES, CURTAINS,DECORATIONS, SCENERY TO BE FLAME PROOF AS PER B.S.A. CAL. 21 SECTION 62. PARAPETS, GUARD RAILINGS AND WIRES.
SECTION REFERENCE
FIRE SEPARATION TYPE OF OCCUPANCY GROUP PROPOSED FIRE RATING SECTION 63. SUB-CURB USE.
11. ALL MATERIALS, ASSEMBLIES, FORMS, AND METHODS OF CONSTRUCTION & SERVICE EQUIPMENT
DISTANCE CONSTRUCTION A,B,E,F-2,I,R ,S-2, U FOR EXTERIOR WALL SECTION 64. LIGHTING; GAS METERS; GAS AND OIL APPLIANCES.
DWG NUMBER SHALL MEET THE FOLLOWING REQUIREMENTS: SECTION 65. BOILER ROOMS.
A) IT SHALL HAVE BEEN ACCEPTED PRIOR TO THE EFFECTIVE DATE OF CODE. ALL 0 2 SECTION 66. LODGING HOUSES
>30 SECTION 67. HOTEL AND CERTAIN OTHER CLASS A AND CLASS B DWELLINGS.
B) IT SHALL HAVE BEEN ACCEPTED FOR USE UNDER THE PRESCRIBED CODE TEST METHOD BY THE
DTL NUMBER
COMMISSIONER. SECTION 68. SMOKE DETECTING DEVICES.

CLARIFICATION DETAIL REFERENCE C) IT SHALL HAVE BEEN APPROVED BY THE BOARD OF STANDARDS AND APPEAL. MAXIMUM AREA OF EXTERIOR WALL OPENINGS
TABLE 704.8 TITLE 3 SANITATION AND HEALTH

DWG NUMBER FIRE SEPARATION DISTANCE (FT.) SECTION 75. WATER SUPPLY.
SEISMIC NOTES CLASSIFICATION
OF OPENING
GREATR THAN 5 AND GREATR THAN 10 AND GREATR THAN 30 SECTION 76.
SECTION 77.
WATER-CLOSET AND BATH ACCOMMODATIONS.
PLUMBING AND DRAINGES.
NOT MORE THAN 10 NOT MORE THAN 15
DTL NUMBER SECTION 78. REPAIRS.
L.L. 17/95
UNPROTECTED 10% 15% NO LIMIT SECTION 79. HEATING.
CLARIFICATION DETAIL REFERENCE SECTION 80. CLEANLINESS.
K. BUILDING SEPARATIONS.
SECTION 81. RECEPTACLE FOR WASTE MATTER.
ALL STRUCTURES SHALL BE SEPARATED FROM ADJOINING STRUCTURES. SEPARATION DUE TO SEISMIC FORCES SHALL ALLOW
DWG NUMBER FOR 1 INCH DISPLACEMENT FOR EACH 50 FEET OF TOTAL BUILDING HEIGHT. SMALLER SEPARATION MAY BE PERMITTED WHEN FIRE WALL FIRE-RESISTANCE RATINGS SECTION 82.
SECTION 83.
PRIVACY.
JANITOR OR HOUSEKEEPER.
THE EFFECTS OF POUNDING CAN BE ACCOMMODATED WITHOUT COLLAPSE OF THE BUILDING. TABLE 705.4
SECTION 84. CONSTRUCTION STANDARD FOR THE CONTROL OF NOISE.
FIRE-RESISTANCE RATING (HOURS) PROPOSED FIRE-RESISTANCE RATING
GROUP (HOURS)
FIREPROOF MULTIPLE DWELLINGS
DTL NUMBERS CARBON MONOXIDE & SMOKE DETECTOR NOTES A,B,E,H-4,I,R-1,R-2,U 3 3
F-2,S-2,R-3,R-4 2 2 TITLE 1 FIRE PROTECTION
ELEVATION REFERENCE
1. DWELLING UNITS SHALL BE EQUIPPED WITH CARBON MONOXIDE & SMOKE
DETECTING DEVICES RECEIVING THERI PRIMARY POWER FROM THE BUILDING SECTION 101. REQUIREMENTS FOR FIREPROOF CONSTRUCTION.
DWG NUMBER WIRING AND THERE SHALL BE NO SWITCHES IN THE CIRCUIT OTHER THAN THE
OVER CURRENT DEVICE PROTECTING THE BRANCH CIRCUIT.
FIRE-REISTANCE RATING REQUIREMENTS FOR SECTION 102.
SECTION 103.
STAIRS.
EGRESS FROM APARTMENTS.
2. ALL CARBON MONOXIDE & SMOKE DETECTING DEVICES REQUIRED TO BE PROVIDED AND INSTALLED WITHER BE ACCEPTED PRESENT SECTION 104. BULKHEADS.
WORK POINT TO RULES AND REGULATIONS PROMULGATED BY THE COMMISSIONER, APPROVED BY THE BOARD OF STANDARD APPEALS OR BE FIRE BARRIER ASSEMBLIES BETWEEN FIRE AREAS SECTION 105.
106. SEPERATION AND VENTILATION
CELLAR AND BASEMENT STAIRS.OF STAIRS.
LISTED BY A NATIONALLY RECOGNIZED INDEPENDENT LATORATORY THAT MAINTAINS PERIODIC INSPECTIONS OF PRODUCTION OF SECTION 107. PUBLIC HALLS.
TABLE 706.3.7
LISTED EQUIPMENT AND WHOSE LISTING STATES THAT EQUIPMENT MEETS NATIONALLY RECOGNIZED STANDARDS. SECTION 108. PARTITIONS
3. NO DEVICE WHALL BE DEEMED TO BE IN COMPLIANCE UNLESS IT IS OF EITHER THE IONIZATION CHAMBER OR PHOTOELECTRIC TYPE. FIRE-RESISTANCE RATING PROPOSED FIRE-RESISTANCE RATING
SUCH DEVICES SHALL BE IN COMPLIANCE WITH THE REQUIREMENTS OF REFERENCE STANDARD RS-11 AND SHALL BE INSTALLED IN A OCCUPANCY GROUP (HOURS) (HOURS) TITLE 2 SANITATION
ELEVATION MARK
MANNER CONSISTENT WITH THE REQUIREMENTS OF REFERENCE STANDARD RS-17-12. A,B,E,F-2,H-4,H-5,I,M,R S-2 2 2
4. HARDWIRED CARBON MONOXIDE DETECTORS SHALL COMPLY WITH RX17-13 AND INSTALLED IN ACCORDANCE WITH RS17-14. IT SHALL SECTION 115. INTERIO WATER-CLOSETS AND BATHROOMS.
BE PROVIDED IN EVERY DWELLING UNIT WITHIN FIFTEEN FEET OF THE PRIMARY ENTRANCE OF EACH BEDROOM. HARDWIRE CARBON SECTION 116. WATER-CLOSETS IN CERTAIN CLASS B MULTIPLE DWELLINGS.

SPOT ELEVATION
MONOXIDE DETECTORS SHALL BE PROVIDED OUTSIDE BOILER ROOM.
FIRE DOOR AND FIRE SHUTTER FIRE PROTECTION SECTION 117. EMPLOYEES' WATER-CLOSETS.

RATINGS TABLE 715.3


DEP NOTES ( WASTE WATER) TYPE OF ASSEMBLY
REQUIRED
ASSEMBLY
MINIMUM FIRE DOOR
AND FIRE SHUTTER
PROPOSED FIRE DOOR
AND FIRE SHUTTER APPLICATION NOTES
SURFACE ELEVATION
RATING SHUTTER ASSEMBLY SHUTTER ASSEMBLY
THE FACILITIY DOES NOT CONTAIN ANY OF FOLLOWING: (HOURS) RATING (HOURS) RATING (HOURS) 1. PURGE SYSTEM & EMERGENCY
GENERATOR ARE FILED UNDER THIS APPLICATION.
FIRE WALLS AND FIRE BARRIERS HAVING A 4 3
* DENTAL FACILITIES * IN-GROUND SPRINKLERS OR IRRIFATION 3
PARTITION KEY REQUIRED FIRE-RESISTANCE RATING GREATER 3 3 2. SEWER CONNECTION IS FILED UNDER SEPARATE APPLICATION.
* WELLS * CHEMICALLY TREATED BOILERS 1 1/2 1 1/2
THAN 1 HOUR 2 3. BUILDER'S PAVEMENT PLAN IS FILED UNDER SEPARATE APPLICATION.
* WATER TANKS * PHOTO PROCESSING FACILITY 1 1/2 1 1/2
* CAR WASH OR CAR REPAIR * LAUNDROMAT 4. FIRE PROTECTION PLAN SHALL FILED SEPARATE.
* RESTAURANT OR FOOD PROCESSING AREA * DRY CLEANING FACILITIES FIRE BARRIERS HAVING A REQUIRED FIRE-RESISTANCE 5. CURB CUTS ARE FILED UNDER SEPARATE APPLICATION.
COMPOSITE PARTITION KEY
* BIDETS RATING OF 1 HOUR: SHAFT, EXIT ENCLOSURE AND EXIT 6. FIRE ALARM FILE UNDER SEPARATE APPLICATION.
PASSAGEWAY WALLS OTHER FIRE BARRIERS 1 1 1 1/2
1 3/4 7. ELEVATOR UNDER SEPARATE APPLICATION.
8. SPRINKLER UNDER THIS APPLICATION.
GLAZING TYPE CONTROL INSPECTION ITEMS FIRE PARTITIONS:
CORRIDOR WALLS 1 3/4 1 1/2
EMERGENCY POWER SYSTEMS (GENERATORS) BC 1704.13, BC 2702 OTHER PARTITIONS 1 3/4 1 1/2
MASONRY BC 1704.5 3 1 1/2
DOOR NUMBER KEY STRUCTURAL SAFETY - STRUCTURAL STABILITY BC 1704.19 EXTERIOR WALLS 2 1 1/2 1 1/2
EXCAVATION - SHEETING, SHORING, AND BRACING BC - 1704.19 BC 3304.4.1 1 3/4
SITE STORM DRAINAGE DISPOSAL AND DETENTION SYSTEM INSTALLATION BC 1704.20
BC 1704.21
SMOKE DETECTOR / CO2 SENSOR
SPRIKLER SYSTEMS
FIRESTOP, DRAFTSTOP, AND FIREBLOCK SYSTEMS BC 1704.25
MULTIPLE DWELLING LAW OF N. Y. STATE
CONCRETE TEST CYLINDERS TR2 BC 1905.6
TR3 BC 1905.3 MULTIPLE DWELLINGS SHALL COMPLY WITH CHAPTER 713 OF THE THE LAW OF 1929
CONCRETE DESIGN MIX
AN ACT IN RELATION TO MULTIPLE DWELLINGS, CONSTITUING CHAPTER SIXTY-ONE-A OF CONSOLIDATED
PRELIMINARY 28-116.2.1, BC 109.2
EXIT SIGN, LAWS BECAME A LAW APRIL 18, 1929, WITH THE APPROVAL OF THE GOVERNOR. PASSED THREE-FIFTHS
FOOTING AND FOUNDATION BC 109.3.1
ARROW INDICATES DIRECTION OF EGRESS BEING PRESENT. THE PEOPLE OF THE STATE OF NEW YORK, REPRESENTED IN SENATE AND ASSEMBLY,
ENERGY CODE COMPLIANCE INSPECTIONS BC 109.3.5
FIRE-RESISTANCE RATED CONSTRUCTION BC 109.3.4 DO ENACT AS FOLLOWS:
FINAL 28-116.2.4.2, BC 109.5 CHAPTER SIXTY-ONE-A OF THE CONSOLIDATED LAWS REV.# DATE DESCRIPTION
DIRECTIVE 14 OF 1975,
MECHANICAL VENTILATION
ARTICLE
1. INTRODUCTORY PROVISIONS; DEFINITIONS ( SECTIONS 1-4 ) KEY PLAN

ALLOWABLE HEIGHT & BUILDING AREA 2. MISCELLANEOUS APPLICATION PROVISIONS ( SECTIONS 8-14 )
3. MULTIPLE DWELLINGS, GENERAL PROVISIONS ( SECTIONS 25-84 )
4. FIREPROOF MULTIPLE DWELLINGS ( SECTIONS 100-117 )
N
OCCUPANCY TYPE OF CONSTRUCTION ARTICLE 1 INTRODUCTORY PROVISIONS; DEFINITIONS
MATERIALS INDICATIONS GROUP
TYPE IB SECTION 1. SHORT TITLE.
SECTION 2. LEGISLATIVE FINDING.
RESIDENTIAL HEIGHT U.L.
SECTION 3. APPLICATION TO CITIES, TOWNS AND VILLAGES.
(R-2)
BATT INSULATION AREA U.L. SECTION 4. DEFINITIONS
ARTICLE 2 MISCELLANEOUS APPLICATION PROVISIONS
FIRE-RESISTANCE RATING SECTION 8. GENERAL APPLICATION OF CHAPTER TO DWELLINGS.
METAL PANEL
SECTION 9. BUILDING CONVERTED OR ALTERED.
REQUIREMENT FOR BUILDING SECTION 10. TIME FOR COMPLIANCE.

CONCRETE ELEMENTS (HOURS) SECTION 11.


SECTION 12.
DWELLING DAMAGED OR MOVED.
PROHIBITED USED.
SECTION 13. APPLICATION OF CHAPTER TO EXISTING DWELLINGS.
BUILDING ELEMENT TYPE I
SECTION 14. APPLICATION OF CHAPTER TO UNCOMPLETED DWELLINGS. PROJECT
CONCRETE BLOCK
ARTICLE 3 MULTIPLE DWELLINGS ------ GENERAL PROVISIONS

STRUCTURAL FRAME
B
SECTION 25. APPLICATION OF ARTICLE 3
1668 EASTERN PARKWAY
EARTH / BACKFILL
INCLUDING COLUMNS, GIRDERS, TRUSSES 2 TITLE 1 LIGHT AND AIR BROOKLYN, NEW YORK
BEARING WALLS SECTION 26. HEIGHT, BULK AND OPEN SPACE.
STUCCO EXTERIOR 2 SECTION 28. TWO OR MORE BUILDING ON THE SAME LOT.
INTERIOR 2 SECTION 29. PAINTING OF COURTS AND SHAFTS.

NONBEARING WALLS AND PARTITIONS


SECTION 30.
SECTION 31.
LIGHTING AND VETILAYION OF ROOMS.
SIZE OF ROOMS.
CELLAR FLOOR PLAN
GRAVEL / CRUSHED STONE EXTERIOR SEE TABLE 602 SECTION 32. ALCOVES.
NONBEARING WALLS AND PARTITIONS SECTION 33. COOKING SPACE.
INTERIOR 0 SECTION 34. ROOMS IN BASEMENTS OR CELLARS.
SECTION 35. ENTRANCE DOORS AND LIGHTS. SEAL & SIGNATURE: DATE: 04-20-16
RIGID INSULATION
FLOOR CONSTRUCTION SECTION 36. WINDOWS AND SKYLIGHTS FOR PUBLIC HALLS AND STAIRS. PROJECT No: 201601
INCLUDING SUPPORTING BEAMS AND JOISTS 2 SECTION 37. ARTIFICIAL HALL LIGHTING
DRAWING BY: CC
WATERPROOFING / ROOFING MEMBRANE ROOF CONSTRUCTION CHK BY: M Kang
INCLUDING SUPPORTING BEAMS AND JOISTS 1
DWG No:

2HR FIRE RATED WALL

A-002.00
SHAFT WALL

PAGE: 02 OF 32
PLUMBING CHASE
HANDICAPPED ADAPTABILITY NOTES
CL MICHAEL KANG
ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619

CL

(FIG. 604.5.3) (FIG. 604.3)

CL CL

* 18" MIN. TO A FIXTURE


(a) WATER CLOSET LOCATION (b) PARALLEL APPROACH

CL CL

(a) (b)
(c) FORWARD APPROACH

* IF BOTH CLOSER AND LATCH ARE PROVIDED


** 48" MIN. IF BOTH CLOSER AND LATCH PROVIDED
* 48" MIN. IF CLOSER IS PROVIDED

(b) (c)

REV.# DATE DESCRIPTION

KEY PLAN
CL CL

BACK WALL
CL CL CL CL N
SEAT

SEAT

CL
CL
(a) (WITHOUT SEAT) (b) (WITH SEAT) (a) (WITHOUT SEAT) (b) (WITH SEAT)
(a) ELEVATION (b) PLAN STANDARD ROLL-IN TYPE STANDARD ROLL-IN TYPE STANDARD ROLL-IN TYPE STANDARD ROLL-IN TYPE
WITHOUT PERMANENT SEAT (FIG. 608.3.2) (FIG. 608.3.2) (FIG. 608.5.2) (FIG. 608.5.2)
(FIG. 607.2) (FIG. 607.4.2) (FIG. 607.5) (FIG. 608.2.2) (FIG. 608.5.1)

PROJECT

1668 EASTERN PARKWAY


ADJUSTABLE
COUNTER SEGMENT BROOKLYN, NEW YORK
RANGE

2
ADA DIAGRAM
TURNING
SPACE
GALLERY SUGGESTED SLIP JOINT
SEAL & SIGNATURE: DATE: 04-20-16
(FIG. 505.7) DIM.
(a) ELEVATION (b) PLAN IN TAIL PIECE PROJECT No: 201601
WITH PERMANENT SEAT DRAWING BY: CC
(FIG. 607.2) (FIG. 607.2) (FIG. 607.4.1) (FIG. 604.5.1) (FIG. 604.5.2) (FIG. 604.7)
CHK BY: M Kang
DWG No:

A-003.00
PAGE: 03 OF 32
62'-7" ZONING ANALYSIS
3RD - 6RH FLOOR ZONING AREA CALCULATIONS 3RD-6TH FLOOR AREA DEDUCTIONS

PLUMBING DEDUCTIONS ZONING MAP & SITE LOCATION


COMMERCIAL FLOOR AREA P1 3.69
M2=(11'-6" + 19'-3") 11'-6"
DEDUCTION P2 0.89 X 11'-6" / 2
NAME GROSS AREA ZONING AREA

11'-6"
AREA
P3 7.38 X08 X09 X10 = 176.81 SF X11
MICHAEL KANG
MECH. GFA = (62'-7" + 84'-2" ) X 32'-4"
GFA 4083.9 SF 356.5 SF 3727.4 SF P4 11.25
KING RM KING RM D/D RM D/D RM
19'-3" / 2 + 84'-2"X 20'-4" ARCHITECT, PLLC.
=2372.46 + 1711.40 Architectural, Interior Design, Zoning & Building Code Expertise
P5 5.50 P9= 7'-0" X 9" M3=11'-1" X 6'-3" 11'-1"
=4083.9 SF
37-01 Main Street, Suite #308, Flushing, NY 11354
P8= 7'-2" X 9"

6'-3"

32'-4"
= 5.25 SF = 69.27 SF 2'-3" michaelkangra@yahoo.com
P6 5.88 = 5.38 SF 7'-2" 2'-0"

2'-11"
P10= 7'-2" X(STRETCHER
ELEV #1 9"
ELEV #2
Tel: (718) 353-2929

9"
P7 5.38 DN
OTB 1= (2'-3" + 4'-3")

9"

9"
(2500 LBS)
= 9.56 SF ADAPTABLE)
7'-2" Fax: (718) 661-1619
PLUMBING CHASE M1= 2'-0" X 7'-9" STAIR 2 STAIR 1 X 2'-11" / 2

6'-0"
7'-0" M4=3'-8" X 6'-0" 4'-3"
P8 5.38 = 15.5 SF
11" UP =9.48 SF
= 22 SF

7'-9"
P9 5.25

52'-8"
MECH. SPACE & VENT DUCT 3'-8" P3= (5'-3" X 9") + (2'-9"X1'-3")

5'-6"
P6= 7'-10" X 9" P5= 7'-4" X 9" P4= (7'-6" X 9") + (2'-6"X2'-3")
P10 9.56 OTB 2= 11" X 5'-6" = 5.88 SF = 5.5 SF = 5.625 + 5.625 = 3.94 + 3.44
UP
=5.04 SF = 11.25 SF 9" = 7.38 SF
OPEN TO BELOW AREA TOTAL 60.16 8"

9"
2'-3"
7'-2" DN

1'-4"
P2= 1'-4" X 8"

5'-3"
P7= 7'-2" X 9" 2'-6" 7'-6" = 0.89 SF

7'-10"

7'-4"
9"
= 5.38 SF
ZONING MAP: 17a PROJECT LOCATION

6'-4"
MECHANICAL DEDUCTIONS

2'-9"
P1= 6'-4" X 7" PROPERTY INFO
M1 15.50 9" 9" 1'-3"
= 3.69 SF
7" PROPOSED NEW 6-STORY COMMERCIAL BUILDING PURSUANT TO HOTEL PROGRAMS

20'-4"
M2 176.81
X07 X06 X05 X04 X03 X02 X01 ADDRESS 1688 EASTERN PARKWAY, BROOLYN, NY 11233
M3 69.27 KING RM KING RM D/D RM ADA RM KING RM KING RM KING RM
BLOCK # 1465
M4 22.00 LOT # 20
TOTAL 283.58 ZONE C8-2
ZONING MAP 17a
LOT AREA 11482 SF
OPEN TO BELOW AREA DEDUCTIONS
84'-2"
OTB 1 7.67 USE REGULATIONS
N
OTB 2 5.04 PERMITTED USE (ZR22-00) GROUP 4 -14,16
SUB-TOTAL 12.71 PROPOSED USE GROUP GROUP 5 (HOTEL)
PROPOSED OCCUPANCY GROUP R-1
TOTAL DEDUCTIONS BULK REGULATIONS
60.16 + 283.58 + 12.71 =356.45 ZR 33-122 MAX. FAR FOR COMMERCIAL BUIDLING IN C8-2
62'-7" PROPOSED COMMERCIAL ZFA 22942.8 SF
MAXIMUM ALLOWED COMMERCIAL FAR 2.00 (C8-2)
MAXIMUM ALLOWED COMMERCIAL AREA 11482 X 2.00 = 22,964 SF > 22,942.8 SF... OK
ZR 33-442 HEIGHT AND SETBACK - ALTERNATE FRONT SETBACKS
DEPTH OF OPTIONAL FRONT OPEN AREA 15' (NARROW STREET )
208 208 210 211 212
2ND FLOOR AREA DEDUCTIONS D/D RM KING RM D/D RM D/D RM KING RM GFA = (62'-7" + 84'-2" ) X 32'-4"
2ND FLOOR ZONING AREA CALCULATIONS / 2 + 84'-2"X 20'-4" 10' (WIDE STREET - EASTERN PARKWAY)
PLUMBING DEDUCTIONS =2372.46 + 1711.40 HEIGHT ABOVE STREET LINE 60'
=4083.9 SF
COMMERCIAL FLOOR AREA P7= 7'-2" X 9" P8= 7'-0" X 9" P9= 7'-2" X 9"
P1 3.69 SKY EXPOSURE PLANE RATIO 3.7(V) : 1(H) (NARROW STREET)

32'-4"
= 5.25 SF 2'-3"
= 5.38 SF = 9.56 SF
7'-2" 2'-0"
DEDUCTION P2 0.89 7.6(V) : 1(H) (WIDE STREET)

2'-11"
ELEV #1 ELEV #2
NAME GROSS AREA ZONING AREA

9"
DN
OTB 1= (2'-3" + 4'-3")

9"

9"
(2500 LBS) (STRETCHER
AREA ADAPTABLE)

P3 7.38 M1= 2'-0" X 7'-9" STAIR 2


11" 7'-0" 7'-2" 4'-3" STAIR 1 X 2'-11" / 2 PROPOSED BUILDING HEIGHT 64'-9" SEE SKY EXPOSURE PLANE DIAGRAM
= 15.5 SF UP =9.48 SF

7'-9"
GFA 4083.9 SF 79 SF 4004.9 SF P4 7.38 ZR33-20 YARD REGULATIONS

52'-8"

5'-6"
P5 5.88 P5= 7'-10" X 9" P4= (5'-3" X 9") + (2'-9"X1'-3") P3= (5'-3" X 9") + (2'-9"X1'-3")
OTB 2= 11" X 5'-6" = 5.88 SF = 3.94 + 3.44 = 3.94 + 3.44 FRONT YARD (ZR24-34) NOT REQUIRED
UP
P6 5.38 =5.04 SF 9" = 7.38 SF 9" = 7.38 SF 8" SIDE YARD (ZR33-25) NOT REQUIRED
7'-2" DN

1'-4"
P7 5.38 P2= 1'-4" X 8"

5'-3"

5'-3"
P6= 7'-2" X 9" = 0.89 SF REAR YARD (ZR24-361 C) MIN. 20'

7'-10"
9"
PLUMBING CHASE P8 5.25 = 5.38 SF

6'-4"
PROPOSED REAR YARD 30' > 20' ... OK

2'-9"

2'-9"
P9 9.56 P1= 6'-4" X 7"
MECH. SPACE & VENT DUCT = 3.69 SF ACCESSORY OFF-STREET PARKING REQUIREMENT
9" 1'-3" 1'-3" 7"
SUB-TOTAL 50.79

20'-4"
ZR 36-21 REQUIRED OFF-STREET PARKING SPACES FOR HOTELS
OPEN TO BELOW AREA 207 206 205 204 203 202 201
KING RM KING RM KING RM KING RM KING RM KING RM KING RM MIN. 1 PARKING SPACE REQUIRED PER 12 GUEST ROOMS
MECHANICAL DEDUCTIONS
MIN. 1 PARKING SPACE REQUIRED PER 12 PERSONS FOR COMMON AREAS
M1 15.50
PROPOSED NUMBER OF GUEST ROOMS 72
PROPOSED OCCUPANT LOAD 40 PERSONS
OPEN TO BELOW AREA DEDUCTIONS
84'-2" MIN. NUMBER OF PARKING REQUIRED 72 / 12 + 40 / 12 = 6+3.3 = 9
OTB 1 7.67
PROPSOED NUMBER OF PARKING 11 > 9 ... OK
OTB 2 5.04
N ZR 36-231 WAIVER OF PARKING SPACES
SUB-TOTAL 12.71 REV.# DATE DESCRIPTION
REQUIRED PARKING PACE LESS THAN 25 CAN BE WAIVED
REQUIRED SPACE 9 < 25 ... WAVIED KEY PLAN
TOTAL DEDUCTIONS
ZR 36-62 REQUIRED ACCESSORY OFF-STREET LOADING BERTHS
50.79 + 15.50 +12.71 = 79
62'-7" FIRST 25,000 SF OF FLOOR AREA - NONE
N
PROPOSED ZFA = 22,915 SF < 25,000 SF ... NO LOADING BERTH REQUIRED
ZR 36-711 BICYCLE PARKING
MIN. 1 BICYCLE PARKING REQUIRED PER 10,000 SF

1ST FLOOR AREA DEDUCTIONS PROPOSED ZFA = 22,895.3 / 10,000 = 2 PARKING SPACES REQUIRED
1ST FLOOR ZONING AREA CALCULATIONS
RECEPTION
PROPOSED NUMBER OF BICYCLE PARKING = 2 SPACES ( IN THE CELLAR)
PLUMBING DEDUCTIONS 108 109
COMMERCIAL FLOOR AREA D/D RM KING RM
LOBBY GFA = (62'-7" + 84'-2" ) X 32'-4" FLOOR AREA CHART
P1 3.69 / 2 + 84'-2"X 20'-4"
CL
DEDUCTION P2 0.89 =2372.46 + 1711.40 FLOOR GFA DEDUCTIONS ZFA
NAME GROSS AREA ZONING AREA UP =4083.9 SF
AREA P8= 7'-0" X 9"
2'-3" CELLAR 4083.9 4083.9 0
P3 7.38

32'-4"
= 5.25 SF
2'-0" DN
1 4083.9 55.6 4028.3

2'-11"
GFA 4083.9 SF 55.6 SF 4028.3 SF P4 7.38 ELEV #1 ELEV #2
OTB 1= (2'-3" + 4'-3")
9"

STAIR 2
(2500 LBS) (STRETCHER
ADAPTABLE) PROJECT
P5 5.88 M1= 2'-0" X 7'-9" DN
7'-0" RPZ OFFICE 4'-3" STAIR 1 X 2'-11" / 2 2 4083.9 79.0 4004.9
=9.48 SF
1668 EASTERN PARKWAY
UP
= 15.5 SF
3 4083.9 356.5 3727.4
7'-9"

P6 5.38
52'-8"

DN

TOTAL 30.60 P5= 7'-10" X 9" P4= (5'-3" X 9") + (2'-9"X1'-3") P3= (5'-3" X 9") + (2'-9"X1'-3") 4 4083.9 356.5 3727.4
PLUMBING CHASE
= 5.88 SF = 3.94 + 3.44 = 3.94 + 3.44 BROOKLYN, NEW YORK
UP
9" = 7.38 SF 9" = 7.38 SF 8" 5 4083.9 356.5 3727.4
7'-2" DN

1'-4"
MECHANICAL DEDUCTIONS P2= 1'-4" X 8" 6 4083.9 356.5 3727.4
5'-3"

5'-3"

MECH. SPACE & VENT DUCT P6= 7'-2" X 9" = 0.89 SF


7'-10"
9"

M1 15.50 = 5.38 SF TOTAL 28587.3 5601.3 22942.8 ZONING COMPLIANCE

6'-4"
2'-9"

2'-9"

OPEN TO BELOW AREA P1= 6'-4" X 7"


UNIT MIX CHART
9" 1'-3" 1'-3" 7"
= 3.69 SF ZFA CALCULATION
OPEN TO BELOW AREA DEDUCTIONS KING ROOM # D/D ROOM # ADA ROOM # TOTAL #

20'-4"
OTB 1 9.48 107 106 105 104 103 102 101 CELLAR 7 0 0 7 SEAL & SIGNATURE: DATE: 04-20-16
KING RM KING RM KING RM KING RM KING RM KING RM KING RM
PROJECT No: 201601
1 8 1 0 9 DRAWING BY: CC
TOTAL DEDUCTIONS 2 9 3 0 12 CHK BY: M Kang
30.6+15.50+9.48 = 55.58 3 7 3 1 11 DWG No:

4 7 3 1 11
84'-2"
5 7 3 1 11 Z-001.00
N 6 7 3 1 11
TOTAL PAGE: 04 OF 32
52 16 4 72
USE AND OCCUPANCY GROUP ANALYSIS ( PROPOSED BUILDING IS FULLY SPRINKLERED ) EGRESS WIDTH PER OCCUPANT SERVED (TABLE 1005.1)

EXIT ACCESS TRAVEL DISTANCE MAXIMUM OCCUPANTS INDEX (INCHES MIN. NUMBER OF EXITS INDEX (INCHES MIN. NUMBER OF EXITS
(TABLE 1015.1) PER OCCUPANT) FOR OCCUPANT LOAD PER OCCUPANT) FOR OCCUPANT LOAD
MICHAEL KANG
FLOOR USE GROUP OCCUPANCY GROUP MAXIMUM TRAVEL DISTANCE PROPOSED MAXIMUM TRAVEL MAXIMUM COMMON OCCUPANCY GROUP DOOR ALLOWED PROPOSED STAIR ALLOWED PROPOSED ARCHITECT, PLLC.
PROPOSED COMMON PATH DISTANCE ALLOWED PATH ALLOWED Architectural, Interior Design, Zoning & Building Code Expertise
CELLAR HOTEL (7 GUEST ROOMS X 2) 0.2 30 / 2 = 15 EXIT-1 DOOR = 36" > 3" ... OK 0.3 30 / 2 = 15 EXIT-1 STAIR = 44" > 4.5" ... OK 37-01 Main Street, Suite #308, Flushing, NY 11354
(R-1) =14 PERSONS 15 X 0.2 = 3 " EXIT-2 DOOR = 36" > 3" ... OK 15 X 0.3 = 4.5 " EXIT-2 STAIR = 44" > 4.5" ... OK michaelkangra@yahoo.com
81'-1" (BREAKFAST AREA) - EXIT 1 25'-3"
HOTEL HOTEL BREAKFAST AREA Tel: (718) 353-2929
CELLAR 35'-5" (BREAKFAST AREA) - EXIT 2 =16 PERSONS Fax: (718) 661-1619
(5) (R-1)
84'-2" (GUEST ROOM) - EXIT 1 23'-11" 200'-0" 75'-0"
TOTAL = 30 PERSONS
90'-0" (GUEST ROOM) - EXIT 2 (R-1) (R-1)
1ST FLOOR HOTEL (9 GUEST ROOMS X 2) 0.2 23 / 2 = 12 EXIT-1 DOOR = 36" > 2.4" ... OK 0.3 23 / 2 = 12 EXIT-1 STAIR = 44" > 3.6" ... OK
HOTEL HOTEL 84'-2" (GUEST ROOM) - EXIT 1 50'-10" 200'-0" 75'-0" (R-1) =18 PERSONS 12 X 0.2 = 2.4 " EXIT-2 DOOR = 36" > 2.4" ... OK 12 X 0.3 = 3.6 " EXIT-2 STAIR = 44" > 3.6" ... OK
1ST (5) (R-1) 90'-0" (GUEST ROOM) - EXIT 2 (R-1) (R-1) LOBBY AREA
=523/100
HOTEL HOTEL 26'-11" (GUEST ROOM) - EXIT 1 23'-11" 200'-0" 75'-0" =5 PERSONS
2ND (5) (R-1) 89'-6" (GUEST ROOM) - EXIT 2 (R-1) (R-1) TOTAL = 23 PERSONS

HOTEL HOTEL 26'-11" (GUEST ROOM) - EXIT 1 23'-11" 200'-0" 75'-0" 2ND FLOOR HOTEL (12 GUEST ROOMS X 2) 0.2 24 / 2 = 12 EXIT-1 DOOR = 36" > 2.4" ... OK 0.3 24 / 2 = 12 EXIT-1 STAIR = 44" > 3.6" ... OK
3RD-6TH (5) (R-1) 89'-6" (GUEST ROOM) - EXIT 2 (R-1) (R-1) (R-1) = 24 PERSONS 12 X 0.2 = 2.4 " EXIT-2 DOOR = 36" > 2.4" ... OK 12 X 0.3 = 3.6 " EXIT-2 STAIR = 44" > 3.6" ... OK

3RD - 6TH HOTEL (11 GUEST ROOMS X 2) 0.2 22 / 2 = 11 EXIT-1 DOOR = 36" > 2.2" ... OK 0.3 22 / 2 = 11 EXIT-1 STAIR = 44" > 3.6" ... OK
FLOOR (R-1) = 22 PERSONS 11 X 0.2 = 2.2 " EXIT-2 DOOR = 36" > 2.2" ... OK 11 X 0.3 = 3.3 " EXIT-2 STAIR = 44" > 3.6" ... OK

X08 X09 X10 X11 208 208 210 211 212


MECH.
KING RM KING RM D/D RM D/D RM D/D RM KING RM D/D RM D/D RM KING RM

EXIT-1 EXIT-1
ELEV #1 ELEV #2 ELEV #1 ELEV #2
(2500 LBS) (STRETCHER
ADAPTABLE)
DN
DOOR WIDTH = 36" (2500 LBS) (STRETCHER
ADAPTABLE)
DN
DOOR WIDTH = 36"
STAIR 2 STAIR 1 STAIR WIDTH = 44" STAIR 2 STAIR 1 STAIR WIDTH = 44"
UP UP

TRAVEL DISTANCE 1 TRAVEL DISTANCE 1

EXIT-2

EXIT-2
EXIT-1 = 23'-11" + 3'-0" EXIT-1
= 26'-11" < 200'-0"
= 23'-11" + 3'-0"
NE

UP UP
= 26'-11" < 200'-0"
TRAVEL DISTANCE 2 TRAVEL DISTANCE 2
SURE PLA

DN DN
EXIT-2
= 23'-11" + 65'-7" DOOR WIDTH = 36" = 23'-11" + 65'-7"
STAIR WIDTH = 44"
= 89'-6" < 200'-0" = 89'-6" < 200'-0"

7.6
SKY EXPO

COMMON PATH COMMON PATH


X07 X06 X05 X04 X03 X02 X01 = 23'-11" < 75'-0" 207 206 205 204 203 202 201
KING RM KING RM D/D RM ADA RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM
= 23'-11" < 75'-0"

1 REMOTE POINT REMOTE POINT

COMMON PATH
41'-10" > 10'-0" TRAVEL DISTANCE
OCCUPANT LOAD OCCUPANT LOAD
MIN. 10' ALTERNATE FRONT OPEN AREA
11 GUESTROOMS X 2 = 22 PERSONS 12 GUESTROOMS X 2 = 24 PERSONS
COMPLY WITH
ZR 33-442 ROOF
+133'-2"
10'-0"
PROPERTY LINE

6TH FLOOR
REV.# DATE DESCRIPTION
+123'-2"
EXIT-1
10'-0"

KEY PLAN
DOOR WIDTH = 36"

5TH FLOOR
+113'-2" N
PROPOSED BUILDING HEIGHT

EXIT-1
10'-0"

RECEPTION GAS BICYCLE


METER PARKING
108 109 WATER
TRAVEL DISTANCE 1 PANTRY
4TH FLOOR D/D RM KING RM
LOBBY
= 50'-10" + 33'-4"
ELEC.
METER
METER RM.
64'-9"

= 84'-2" < 200'-0" CL


+103'-2" BREAKFAST
60'-0"

AREA
10'-0"

UP
(16 SEATS)BREAKFAST AREA -
COMMON PATH
DN BREAKFAST AREA - BREAKFAST AREA - EXIT-1
= 25'-3" < 75'-0" ELEV #1
3RD FLOOR ELEV #1
(2500 LBS)
ELEV #2
(STRETCHER
TRAVEL DISTANCE 2
(2500 LBS)
ELEV #2
(STRETCHER
TRAVEL DISTANCE 1 STAIR 1 DOOR WIDTH = 36"
STAIR 2 ADAPTABLE)
STAIR 1
= 25'-3" + 10'-2" ADAPTABLE)
= 25'-3" + 55'-10"
COMPACTOR STAIR WIDTH = 44"
DN RPZ OFFICE STAIR 2
+93'-2" UP
= 35'-5" < 200'-0" = 81'-1" < 200'-0" UP
10'-0"

COMMON PATH GUESTROOM -


DN
= 50'-10" < 75'-0" DN EXIT-1
EXIT-2

TRAVEL DISTANCE 1
2ND FLOOR UP = 23'-11" + 3'-0"
PROJECT
TRAVEL DISTANCE 2 UP
TRAVEL DISTANCE 2 = 26'-11" < 200'-0"
DN
+83'-2" EXIT-2 = 50'-10" + 41'-2" EXIT-2
= 23'-11" + 65'-7"
DOOR WIDTH = 36" DOOR WIDTH = 36"
1668 EASTERN PARKWAY

EXIT-2
= 92'-0" < 200'-0" = 89'-6" < 200'-0"
STAIR WIDTH = 44" STAIR WIDTH = 44"
14'-2"

BROOKLYN, NEW YORK


EASTERN PARKWAY
(WIDE STREET) MEAN CURB LEVEL 1ST FLOOR
107 106 105 104 103 102 101 007 006 005 004 003 002 001 GUESTROOM -
+68'-5" +69.0' KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM KING RM
COMMON PATH EGRESS DIAGRAMS
10'-0"

= 23'-11" < 75'-0"

REMOTE POINT REMOTE POINT


SECTION DIAGRAM
CELLAR
SEAL & SIGNATURE: DATE: 04-20-16
COMMON PATH
+59.0' PROJECT No: 201601
TRAVEL DISTANCE
OCCUPANT LOAD OCCUPANT LOAD DRAWING BY: CC
9 GUESTROOMS X 2 = 18 PERSONS 7 GUESTROOMS X 2 = 14 PERSONS CHK BY: M Kang
LOBBY 523/100 = 5 PERSONS BREAKFAST AREA = 16 PERSONS
DWG No:
TOTAL =14+5 = 23 PERSONS TOTAL =14+16 = 30 PERSONS

Z-002.00
PAGE: 05 OF 32
MICHAEL KANG
ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
S
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619

1 1
A-302 A-201
69.32'

62'-5"

10'-21 2" 66.0'


3'-8" 6'-5" 15'-4" 7'-9" 7'-6" 6'-0"
E

G F F BICYCLE

10'-1"
B ELEC. GAS PARKING
METER METER (2 SPACES) WATER
13'-7"

13'-8"
PANTRY

15'-9"
METER
RM.
6 6 F
F
6 BREAKFAST AREA
G 6 F

5'-0"
(16 SEATS) T.O.S EL. +59'-0"

39
6 STAIR 1

'-0"
E 1
8'-3"
4'-0" 6 02
A-2
B ELEV #2 F
ELEV #1 B

8R @ 6.25" EA.
(STRETCHER

9'-0"
F B (2500 LBS)
ADAPTABLE)

6'-11"
COMPACTOR
7'-5"

STAIR 2 C
10'-7" 6'-0" 1'-5" 8'-71 2" 8'-71 2" 9'-31 2" 10'-1"
UP
17'-7"

5 17R @ 7" EA.


7
8R @ 7" EA.
52'-8"

E DN G G
CORRIDOR
5'-0"
AREA: 367 SF
MAX. OCCUPANT = 367/100= 4 PPL
T.O.S EL. +63'-2"
B
1 UP
A-301 1 1 1 1 1
7
C C C
3 3 3 3 3
8'-0"

2 2 2 2 2
1 G 1
A-204 C C
5'-5"

7'-0" 3'-3" 3'-8" 5'-0" 7'-10" 5'-0" 5'-0" 6'-6" 5'-5" 5'-0" 5'-0" 5'-4" 5'-3" 5'-7"
2 2
1
A A A A A A
A

20'-31 2"
S S S S S S S

007 006 005 004 003 002 001


12'-6"

A1 A1 A1 A1 A1 A1
11'-11"

KING RM KING RM KING RM KING RM KING RM KING RM KING RM


ROOM AREA: 150 SF ROOM AREA: 142 SF ROOM AREA: 196 SF ROOM AREA: 184 SF ROOM AREA: 170 SF ROOM AREA: 165 SF ROOM AREA: 164 SF
WINDOW AREA = 32 SF WINDOW AREA = 32 SF WINDOW AREA = 32 SF WINDOW AREA = 32 SF WINDOW AREA = 32 SF WINDOW AREA = 32 SF WINDOW AREA = 32 SF UP
32/150 = 21% > 10% 32/142 = 23% > 10% 32/196 = 16% > 10% 32/184 = 17% > 10% 32/170 = 19% > 10% 32/165 = 20% > 10% 32/164 = 20% > 10%
REV.# DATE DESCRIPTION
11'-0" 11'-4" 11'-10" 11'-10" 11'-4" 11'-0" 11'-0"
KEY PLAN

N
2'-6" 7'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 2'-8"
5'-0"
2" 84'-2" 9'-3"
2
A-101

8"
1 T.O.P EL. +66'-0"
A-203

PROJECT

1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

CELLAR FLOOR PLAN

SEAL & SIGNATURE: DATE: 04-20-16


PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

N
A-101.00
PAGE: 06 OF 32
MICHAEL KANG
ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
S
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619

3 4"
-7
38'

18'-0"

17
.6'

8'-6"

68
P1

'-11
3 4" "
10 6'-0

"
3D VIEW

8'-6"
SCALE: N.T.S
P2

9" NOTE:
1. REBAR AMERICAN GRADE 60 SIZE #3
2. 3000 PSI CONCRETE OR GREATER

41'-10"
3. WEIGHT 200 POUNDS

8'-6"
P3

8'-6"
1 1
P4 A-302 A-201

2" 4 1 2"
62'-5"
3
T.O.S. EL.+69'-7" 4"
1'-4" 1'-2" 1'-7"
3'-4" 6'-9" 4'-6" 9'-7" 3'-0" 6'-0" 3'-7" 21'-7"

T.O.S. EL.+69'-0"

2"
6

17
4'-1

3"
3'-8" 11'-0" 11'-0" 33'-111 4" 2 EA. #3 REBAR

1
1 2"
108 109
10'-0"

RECEPTION
B D/D RM A1 KING RM B
ROOM AREA: 180 SF ROOM AREA: 175 SF 9"

39
15'-5"
T.O.S EL. +69'-7"

'-0"
WINDOW AREA = 43 SF WINDOW AREA = 60 SF
6
1'-10"

43/180 = 24% > 10% 60/175 = 34% > 10% LOBBY


SECTION
3R @ 7" EA.

ELEC.
S S T.O.S EL. +69'-0"
A1 CLOSET SCALE: N.T.S
UP 3'-8"

3'-8"
STAIR 2 2 E
F
4'-0" 1
8'-3" 3
6'-5" 02
DN A-2
9'-7"

6 4 F
ELEV #1 ELEV #2
T.O.S EL. +67'-10" "

9R @ 6.25"EA.
(STRETCHER
3'-8
124'-6"

(2500 LBS)
3'-8" 3'-8" ADAPTABLE)

6'-11"

7'-7"
B 7
DN
3'-11" 7'-0" 3'-6" 8'-71 2" 8'-71 2" 4'-0" 5'-31 2" 7'-4"

3'-8"
UP
1 RPZ OFFICE 17R @ 7" EA. STAIR 1
10R @ 6.4" EA.

2 7
1 1
17R @ 7" EA.

A-204
DN
6'-5"
52'-8"

CORRIDOR E B G T.O.P. EL.+68'-0"


D
5'-0"
AREA: 367 SF T.O.S EL. +73'-2"
MAX. OCCUPANT = 367/100= 4 PPL
UP B DN
T.O.S EL. +74'-0" 1 REV.# DATE DESCRIPTION
1 1
3'-8"

1 1 1
A-301 DN
7
C C C

20
3 3 3 3 3 KEY PLAN

'-0"
8'-0"

2 2 2 2 2
G 1
C
5'-0"

7'-0" 3'-3" 3'-8" 5'-0" 7'-10" 5'-0" 5'-0" 6'-6" 5'-5" 5'-0" 5'-0" 5'-5" 5'-3" 5'-7"
2 2
N
1
A A A A A A
A

20'-31 2"
S S S S S S S
12'-10"

107 106 105 104 103 102 101


11'-11"

A1 A1 A1 A1 A1 A1
KING RM KING RM KING RM KING RM KING RM KING RM KING RM
ROOM AREA: 150 SF ROOM AREA: 142 SF ROOM AREA: 196 SF ROOM AREA: 184 SF ROOM AREA: 170 SF ROOM AREA: 165 SF ROOM AREA: 164 SF
WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF
46/150 = 31% > 10% 46/142 = 32% > 10% 46/196 = 23% > 10% 46/184 = 25% > 10% 46/170 = 27% > 10% 46/165 = 28% > 10% 46/164 = 28% > 10%

11'-0" 11'-4" 11'-10" 11'-10" 11'-4" 11'-0" 11'-0" '-0"


10

2'-6" 7'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 2'-8"
5'-0"
2" 84'-2" 9'-3"
PROJECT

47
'-3
3 4"
"
8'-6 1668 EASTERN PARKWAY
T.O.P EL. +65'-2"
1 BROOKLYN, NEW YORK
30'-0"

A-203

18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 1ST FLOOR PLAN

18
'-0"
P11
8'-6"

SEAL & SIGNATURE: DATE: 04-20-16


P5 P6 P7 P8 P9 P10
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
2" 129'-10" 2" DWG No:

N
A-102.00
PAGE: 07 OF 32
MICHAEL KANG
1 1
ARCHITECT, PLLC.
A-302 A-201 Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
S
michaelkangra@yahoo.com

62'-5" Tel: (718) 353-2929


Fax: (718) 661-1619
22'-3" 1'-3"

CANOPY
1'-6" 9'-0" 2'-10" 9'-9" 3'-7" 9'-0" 3'-7" 9'-0" 3'-7" 9'-0" 1'-7"

5'-0"
11'-0" 11'-0" 13'-0" 12'-10" 11'-41 4"
208 208 210 211 212
D/D RM KING RM D/D RM D/D RM KING RM

11'-0"
12'-1"

12'-5"

12'-5"
ROOM AREA: 153 SF ROOM AREA: 143 SF ROOM AREA: 228 SF ROOM AREA: 224 SF ROOM AREA: 217 SF
WINDOW AREA = 61 SF WINDOW AREA = 61 SF WINDOW AREA = 61 SF WINDOW AREA = 61 SF WINDOW AREA = 61 SF

15'-5"
61/153 = 40% > 10% 61/143 = 43% > 10% 61/228 = 27% > 10% 61/224 = 27% > 10% 61/217 = 28% > 10%
19'-4"

A1 A1 A1 A1
8'-5"
S S S S S G
A A A

39
3'-8"

'-0"
3'-8"
1 2
2
5'-0"

5'-0"

5'-0"
- 2 02
1 B A
ELEV #1 ELEV #2
(STRETCHER DN "
(2500 LBS) '- 8
3'-5" ADAPTABLE) 3'-3" 3'-31 2" 3

8'-7"
3'-8" 3'-8"
1 STAIR 1
3'-8"

5'-0"

5'-0"
8'-71 2" 8'-71 2"

3'-8"
A-204 3'-0" 3'-8" 7'-3" 7'-0" UP
2 1 17R @ 7" EA.
1 1 7
17R @ 7" EA.
52'-8"

14'-2"

CORRIDOR E G
F D

5'-0"
AREA: 401 SF T.O.S EL. +83'-2"
UP MAX. OCCUPANT = 401/100= 4 PPL B
1
STAIR 2 1 1
3'-8"

1 1 1
A-301 DN 7
C C 3 C
3 3 3 3

8'-0"
2 2 2 2 2
G 1
C
5'-0"

7'-0" 3'-3" 3'-8" 5'-0" 7'-10" 5'-0" 5'-0" 6'-6" 5'-5" 5'-0" 5'-0" 5'-5" 5'-3" 5'-7"
2

1 REV.# DATE DESCRIPTION


A A A A A A
A KEY PLAN

20'-31 4"
S S S S S S S
19'-2"

207 206 205 204 203 202 201 N


12'-6"

A1 A1 A1 A1 A1 A1
11'-11"

KING RM KING RM KING RM KING RM KING RM KING RM KING RM


ROOM AREA: 150 SF ROOM AREA: 142 SF ROOM AREA: 196 SF ROOM AREA: 184 SF ROOM AREA: 170 SF ROOM AREA: 165 SF ROOM AREA: 164 SF
WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF
46/150 = 31% > 10% 46/142 = 32% > 10% 46/196 = 23% > 10% 46/184 = 25% > 10% 46/170 = 27% > 10% 46/165 = 28% > 10% 46/164 = 28% > 10%
11'-0" 11'-4" 11'-10" 11'-10" 11'-4" 11'-0" 11'-0"

PROJECT

2'-6" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 2'-8" 1668 EASTERN PARKWAY
BROOKLYN, NEW YORK

84'-2" 2N FLOOR PLAN

SEAL & SIGNATURE: DATE: 04-20-16


1 PROJECT No: 201601
DRAWING BY: CC
A-203 CHK BY: M Kang
DWG No:

N
A-103.00
PAGE: 08 OF 32
1 1
MICHAEL KANG
A-302 A-201 ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
S
michaelkangra@yahoo.com
62'-5" Tel: (718) 353-2929
Fax: (718) 661-1619

1'-6" 9'-0" 3'-7" 9'-0" 3'-7" 9'-0" 3'-7" 9'-0" 3'-7" 9'-0" 1'-7"

11'-0" 11'-0" 13'-0" 12'-10" 11'-31 4"

X08 X09 X10 X11 MECH. ROOM


KING RM KING RM D/D RM D/D RM

11'-0"
12'-1"

12'-5"
ROOM AREA: 153 SF ROOM AREA: 143 SF ROOM AREA: 228 SF ROOM AREA: 224 SF
WINDOW AREA = 61 SF WINDOW AREA = 61 SF WINDOW AREA = 61 SF WINDOW AREA = 61 SF

15'-5"
61/153 = 40% > 10% 61/143 = 43% > 10% 61/228 = 27% > 10% 61/224 = 27% > 10% (3) HOT WATER HEATERS
19'-4"

17'-9"
A1 A1 A1 B MFR: AMERICAN STANDARD
S S S S
MODEL #:D-100-250-A 8'-5"
G
A A MEA #: 4-99-E

39
3'-8"

'-0"
3'-8"
2 1 2
5'-0"

F 1

5'-0"
-2 02
1
S B A
ELEV #1 ELEV #2
(STRETCHER DN "
F
3'-5"
(2500 LBS)
ADAPTABLE) 3'-3" 3'-2" 3'-8

8'-7"
3'-8" 3'-8"
3'-8"

5'-0"

5'-0"
8'-71 2" 8'-71 2" 7'-01 2"

3'-8"
3'-0" 3'-8" 7'-3" UP
1
17R @ 7" EA.

2 2 17R @ 7" EA. 7


1 1 6
A-204
52'-8"

14'-2"

B E B G
F D CORRIDOR

5'-0"
AREA: 401 SF
UP MAX. OCCUPANT = 401/100= 4 PPL C B
1
3'-8"

1 1 1 1
A-301 DN 7 1A
C 1'-6" C
3 C 3 3 3

7'-1"
2 2 2
G 1 C
5'-0"

7'-0" 3'-3" 3'-8" 5'-0" 5'-2" 2


5'-0" 10'-0" 2A
4'-7" 5'-5" 5'-0" 5'-0" 5'-5" 5'-3" 5'-7"
2

1
A A A A A A
A REV.# DATE DESCRIPTION

20'-31 4"
S S S S S S S
19'-2"

KEY PLAN

X07 X06 X05 X04 X03 X02 X01


13'-1"

A1 A1 A1 A1 A1 A1
11'-11"

KING RM KING RM D/D RM ADA RM KING RM KING RM KING RM N

ROOM AREA: 150 SF ROOM AREA: 137 SF ROOM AREA: 173 SF ROOM AREA: 201 SF ROOM AREA: 170 SF ROOM AREA: 165 SF ROOM AREA: 164 SF
WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF WINDOW AREA = 46 SF
46/150 = 31% > 10% 46/137 = 34% > 10% 46/173 = 27% > 10% 46/201 = 23% > 10% 46/170 = 27% > 10% 46/165 = 28% > 10% 46/164 = 28% > 10%
11'-0" 11'-0" 11'-4" 12'-8" 11'-4" 11'-0" 11'-0"

PROJECT
2'-6" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 5'-0" 7'-0" 2'-8"
1668 EASTERN PARKWAY
BROOKLYN, NEW YORK

84'-2"
3RD-6TH FLOOR PLAN (TYP.)
1
6TH FLOOR T.O.S EL. +123'-2"
A-203 SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
5TH FLOOR T.O.S EL. +113'-2" CHK BY: M Kang
DWG No:

N
4TH FLOOR T.O.S EL. +103'-2" A-104.00
PAGE: 09 OF 32

3RD FLOOR T.O.S EL. +93'-2"


1 1 MICHAEL KANG
ARCHITECT, PLLC.
A-302 A-201 Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
S
michaelkangra@yahoo.com

Tel: (718) 353-2929


62'-5" Fax: (718) 661-1619

15
1

'-3"
A-204
FLASHING 6"

15'-5"
ROOF
18'-10"

A.F.F (TYP.)

T.O.S EL. +128'-2"

39
'-0"
11
'-7
1

1 2"
-2 02
A
DN
F F

17'-61 2"

12
14'-111 2"

'-1
52'-8"

1 2"
' - 0 "
1 3 4 W4 6
A-204 A-204 A-204 6'-8" 4'-0" 9"
PBX ROOM

8'-0"
1 11'-5"
A-301 DN 7
17'-11"
6
20 SF WINDOW WITH 144
SQ.IN LOUVER BELOW

3'-0"
W4 20 SF WINDOW WITH 144 UP
2'-0"
6'-3" 4'-0" SQ.IN LOUVER BELOW
19'-11" 13'-101 4" 22'-13 4"
12'-3" 15'-0"
REV.# DATE DESCRIPTION
A A A A A A
A

20'-31 4"
KEY PLAN
MTL STAIR
18'-81 2"

14'-8"
N
3'-6'' HT. PARAPET
W/ PRECAST CONC.
COPING (TYP.) 2
A-204

PROJECT

1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

84'-2" ROOF PLAN

SEAL & SIGNATURE: DATE: 04-20-16


1 PROJECT No: 201601
DRAWING BY: CC
A-203 CHK BY: M Kang
DWG No:

N
A-105.00
PAGE: 10 OF 32
MICHAEL KANG
ARCHITECT, PLLC.
ROOF OF ELEVATOR Architectural, Interior Design, Zoning & Building Code Expertise

MACHINE ROOM S
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619

T.O.S EL. +151'-2"

19'-11"

17'-11" STAIR 1
BUILKHEAD

10'-7"
T.O.S EL. +142'-2"

STAIR 2 ELEVATOR
17'-7"

15'-7"
BUILKHEAD MACHINE ROM

4'-0"
T.O.S EL. +142'-2" REV.# DATE DESCRIPTION
T.O.S EL. +142'-2" KEY PLAN

3'-0"
6
N
3'-0"

DN

PROJECT

T.O.S EL. +133'-2" 1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

UPPER ROOF PLAN

SEAL & SIGNATURE: DATE: 04-20-16


PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

N
A-106.00
PAGE: 11 OF 32
MICHAEL KANG
ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
62'-5" 37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com
BUILDING SIZE Tel: (718) 353-2929
Fax: (718) 661-1619

ROOF OF ELEVATOR MACHINE ROOM


+151'-2"

9'-0"
ROOF OF STAIR BUILKHEAD
+142'-2"

9'-0"

3'-6"
3'-6" HT. PARAPET WALL
ROOF
+133'-2"

10'-0"
6TH FLOOR
+123'-2"

10'-0"
5TH FLOOR
+113'-2" METAL PANEL
10'-0"
PROPOSED BUILDING HEIGHT

FIXED AND CASEMENT PAINTED


ALUMINUM WINDOWS
4TH FLOOR
+103'-2"
64'-9"

10'-0"

3RD FLOOR
+93'-2"
REV.# DATE DESCRIPTION
10'-0"

KEY PLAN

N
2ND FLOOR
HOTEL SIGNAGE
+83'-2"

1688
14'-2"

PROJECT

MEAN CURB LEVEL 1ST FLOOR


+69'-0"
1668 EASTERN PARKWAY
+68'-5" BROOKLYN, NEW YORK

WEST ELEVATION

SEAL & SIGNATURE: DATE: 04-20-16


PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

A-201.00
PAGE: 12 OF 32
MICHAEL KANG
ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619

ROOF OF ELEVATOR MACHINE ROOM


STUCCO
+151'-2" 20'-31 2" 39'-0"

9'-0"
12'-11 4" 11'-71 2" 15'-3"

ROOF OF STAIR BUILKHEAD


+142'-2"
METAL STAIR

9'-0"

3'-6"
3'-6" HT. PARAPET WALL
ROOF
+133'-2"

10'-0"
6TH FLOOR
+123'-2"

5TH FLOOR 10'-0"

+113'-2"

STUCCO
10'-0"
PROPOSED BUILDING HEIGHT

4TH FLOOR
+103'-2"
64'-9"

10'-0"

3RD FLOOR
+93'-2" REV.# DATE DESCRIPTION

KEY PLAN
10'-0"

2ND FLOOR
+83'-2"
10'-0"

1ST FLOOR
+73'-2" PROJECT

MEAN CURB LEVEL 1668 EASTERN PARKWAY


10'-0"

DRIVEWAY BROOKLYN, NEW YORK


+68'-5"
2'-10"

REAR YARD
CELLAR NORTH ELEVATION
20'-0"
+63'-2''
PROPOSED SLOPE = 2'-10"/20'
SEAL & SIGNATURE: DATE: 04-20-16
= 1:7.1 < 1:7 ... OK PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

A-202.00
PAGE: 13 OF 32
MICHAEL KANG
ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619

ROOF OF ELEVATOR MACHINE ROOM


+151'-2"

9'-0"
84'-4"

ROOF OF STAIR BUILKHEAD


+142'-2" STUCCO STUCCO

9'-0"

3'-6"
3'-6" HT. PARAPET WALL
ROOF
+133'-2"

10'-0"
6TH FLOOR
+123'-2"
10'-0"

5TH FLOOR
+113'-2"
METAL PANEL
10'-0"
PROPOSED BUILDING HEIGHT

4TH FLOOR
+103'-2"
64'-9"

FIXED AND CASEMENT PAINTED


10'-0"

ALUMINUM WINDOWS

3RD FLOOR
+93'-2"
REV.# DATE DESCRIPTION
10'-0"

KEY PLAN

N
2ND FLOOR
+83'-2"
10'-0"

1ST FLOOR
+73'-2" PROJECT

MEAN CURB LEVEL 1668 EASTERN PARKWAY


10'-0"

+68'-5" BROOKLYN, NEW YORK


CELLAR DRIVEWAY

1'-0"
EAST ELEVATION
+63'-2"
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

A-203.00
PAGE: 14 OF 32
MICHAEL KANG
ARCHITECT, PLLC.

NE
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354

SURE PLA
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619

SKY EXPO
7.6

41'-10"

1 ROOF OF ELEVATOR MACHINE ROOM


+151'-2" STUCCO
52'-8"

9'-0"
21'-71 2" 12'-4" 18'-81 2"

ROOF OF STAIR BUILKHEAD METAL STAIR


+142'-2"

9'-0"

3'-6"
3'-6" HT. PARAPET WALL
ROOF
+133'-2"

10'-0"
6TH FLOOR
PROPERTY LINE

+123'-2"

5TH FLOOR 10'-0"


+113'-2"
10'-0"

STUCCO
PROPOSED BUILDING HEIGHT

4TH FLOOR
+103'-2"
64'-9"

REV.# DATE DESCRIPTION


60'-0"

KEY PLAN
10'-0"

N
3RD FLOOR
+93'-2"
10'-0"

2ND FLOOR
+83'-2" PROJECT

1668 EASTERN PARKWAY


10'-0"

BROOKLYN, NEW YORK

EASTERN PARKWAY 1ST FLOOR SOUTH ELEVATION


(WIDE STREET) +73'-2"
SEAL & SIGNATURE: DATE: 04-20-16
MEAN CURB LEVEL
10'-0"

PROJECT No: 201601


+68'-5" DRAWING BY: CC
CHK BY: M Kang
DWG No:
CELLAR
+63'-2'' A-204.00
PAGE: 15 OF 32
MICHAEL KANG
ARCHITECT, PLLC.
ROOF OF ELEVATOR Architectural, Interior Design, Zoning & Building Code Expertise
MACHINE ROOM

1'-0"
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

+151'-2" Tel: (718) 353-2929


Fax: (718) 661-1619

9'-0"

5'-0"
STUCCO
ROOF OF STAIR ROOF OF STAIR
BULKHEAD BULKHEAD

1'-0"
18'-0"

4'-0"
+142'-2" +142'-2"
STUCCO
METAL STAIR

9'-0"

5'-0"

9'-0"
2'-0"
ROOF ROOF
+133'-2" +133'-2" 14'-111 2"

ROOF OF ELEVATOR
MACHINE ROOM
1'-0"

+151'-2"
9'-0"

STUCCO
ROOF OF STAIR
BULKHEAD
18'-0"

+142'-2"
METAL STAIR
9'-0"

LOUVER SIZE = 12"X24" LOUVER SIZE = 12"X24"

8" 1'-0"
8" 1'-0"

ROOF = 288 SF > 144 SF = 288 SF > 144 SF


2'-0" 2'-0"
+133'-2"
12'-3" 19'-11" 11'-5" 6'-0"

REV.# DATE DESCRIPTION

KEY PLAN

ROOF OF ELEVATOR
MACHINE ROOM
1'-0"

+151'-2"
9'-0"

STUCCO PROJECT

ROOF OF STAIR
BULKHEAD
1668 EASTERN PARKWAY
18'-0"

BROOKLYN, NEW YORK


+142'-2"
SOUTH ELEVATION
9'-0"

ROOF SEAL & SIGNATURE: DATE: 04-20-16


PROJECT No: 201601
+133'-2" DRAWING BY: CC
9'-103 4" 19'-11" 12'-9" CHK BY: M Kang
DWG No:

A-204.00
PAGE: 16 OF 32
ROOF OF ELEVATOR MACHINE ROOM
+151'-2''
CMU/STUCCO WALL CMU/STUCCO WALL MICHAEL KANG
REFER TO 2/EN-101 ASPHALT ROOFING REFER TO 2/EN-101 ARCHITECT, PLLC.
. ELEVATOR MACHINE ROOM
FOR WALL DETALS FOR WALL DETALS Architectural, Interior Design, Zoning & Building Code Expertise
4" RIGID INSULATION 37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com
R VALUE = 20 ROOF OF STAIR BUILKHEAD
Tel: (718) 353-2929
Fax: (718) 661-1619
3'-6" HT. PARAPET
+142'-10"
STAIR 2 WALL STAIR 1

ROOF
+133'-2"

17R @ 7" EA.


17R @ 7" EA.

10'-0"
9'-0"

8'-7"

8'-7"
LAST

A.F.F

A.F.F

A.F.F
8'-0"

8'-0"
A.F.F
ELEVATOR 2'-10" HT. RAILING
STOP (TYP.) 6TH FLOOR
+123'-2"

17R @ 7" EA.

17R @ 7" EA.


10'-0"

10'-0"
8'-7"

8'-7"
A.F.F

A.F.F

A.F.F
8'-0"

8'-0"
A.F.F
REINFORCED CONCRETE SLAB
REFER TO STR. DWG 5TH FLOOR
+113'-2"
17R @ 7" EA.

17R @ 7" EA.


10'-0"

10'-0"
8'-7"

8'-7"
A.F.F

A.F.F

A.F.F
8'-0"

8'-0"

PROPOSED BUILDING HEIGHT


A.F.F
2'-10" HT. RAILING (TYP.) 4TH FLOOR
+103'-2"

64'-9"
ELEVATOR SHAFT #1

ELEVATOR SHAFT #2
17R @ 7" EA.

17R @ 7" EA.


10'-0"

10'-0"
8'-7"

8'-7"
A.F.F

A.F.F

A.F.F
8'-0"

8'-0"
A.F.F
3RD FLOOR
+93'-2"
17R @ 7" EA.

17R @ 7" EA.


10'-0"

10'-0"
8'-7"

8'-7"
A.F.F

A.F.F

A.F.F
8'-0"

8'-0"
A.F.F

2ND FLOOR
+83'-2"
17R @ 7" EA.

17R @ 7" EA.


10'-0"

10'-0"
REV.# DATE DESCRIPTION
8'-7"

8'-7"
A.F.F

A.F.F
8'-0"
A.F.F

KEY PLAN

1ST FLOOR
N
10R @ 6.4" EA.

+73'-2"
5'-4"

4'-1"

17R @ 7" EA.


MEAN CURB LEVEL

10'-0"
DRIVEWAY
8'-0"

8'-0"
A.F.F

A.F.F +68'-5"
8R @ 7" EA.

5'-3"
4'-8"

CELLAR

8R @ 6.25" EA.
+63'-2"

4'-2"
CELLAR
PROJECT
+59'-0"
REFER TO STRUCTURAL 1668 EASTERN PARKWAY
DRAWINGS FOR FOUNDATION BROOKLYN, NEW YORK
1
DETAILS MORE THAN 2 OF CELLAR HT IS
BELOW MEAN CURB LEVEL
DEFINED AS CELLAR SECTION
(NO FLOOR AREA SHALL BE
INCLUDED IN THE ZONING CALCULATION) SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

A-301.00
PAGE: 17 OF 32
SKY EXPOSURE PLANE
PL PL
MICHAEL KANG
1
ROOF OF ELEVATOR MACHINE ROOM ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
+151'-2" 37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


ASPHALT ROOFING ELEVATOR Fax: (718) 661-1619

. MACHINE
7.6 4" RIGID INSULATION MTL. STAIR TO ELEVATOR
ROOM
ROOF OF STAIR BUILKHEAD R VALUE = 20 MACHINE ROOM
+142'-2" CMU/METAL PANEL WALL 3'-6" HT. PARAPET CMU/METAL PANEL WALL
REFER TO 1/EN-101 WALL REFER TO 1/EN-101
FOR WALL DETALS FOR WALL DETALS

ROOF

8"
+133'-10" 8" 8"

10'-0"

8'-7"

8'-7"
A.F.F

A.F.F
8'-0"
A.F.F
2'-6"

2'-6"
6TH FLOOR
PROPERTY LINE

8"
+123'-2" 8" 8"
OPERABLE WINDOW
OPERABLE WINDOW
10'-0"

8'-7"

8'-7"
A.F.F

A.F.F
8'-0"
A.F.F
FIXED WINDOW
FIXED WINDOW

2'-6"

2'-6"
5TH FLOOR

8"
+113'-2" 8" 8"
2 LAYERS OF 5/8" TYPE "X"
10'-0"
PROPOSED BUILDING HEIGHT

8'-7"

8'-7"
GYPSUM BOARD

A.F.F

A.F.F
8'-0"
A.F.F
2 HR FIRE RATED (TYP.)

2'-6"

2'-6"
4TH FLOOR

8"
+103'-2"
64'-9"

8" 8"

ELEVATOR SHAFT #1
60'-0"

10'-0"

REINFORCED CONCRETE SLAB


8'-7"

8'-7"
A.F.F

A.F.F
8'-0"
A.F.F
2'-6" REFER TO STR. DWG

2'-6"
3RD FLOOR

8"
+93'-2" 8" 8"
10'-0"

8'-7"

8'-7"
A.F.F

A.F.F
8'-0"
A.F.F
5'-0"
2'-6"

2'-6"
2ND FLOOR REV.# DATE DESCRIPTION
1'-10"

8"
+83'-2" 8" 8"
KEY PLAN

CANOPY N

8'-7"
A.F.F
8'-0"
(SEE MANUFACTURER 'S DETAIL)

A.F.F
14'-2"

12'-10"

12'-9"

3'-6" HT RETAINING WALL


A.F.F

2'-6"
1ST FLOOR

8"
+73'-2" 8"
MEAN CURB LEVEL 1ST FLOOR 4" CONC. PAVEMENT

3'-6"
8'-7"
+69'-0"

A.F.F
8'-0"

ADJACENT LOT
A.F.F

+68'-5"
REAR YARD
V.I.F

3'-0"
10'-0"

1'-0"
PROJECT
CELLAR
8'-0"

1668 EASTERN PARKWAY


A.F.F

+63'-2"
BROOKLYN, NEW YORK
CELLAR
+59'-0" ELEVATOR PIT REAR YARD
5'-0"

(COORDINATE W/ ELEVATOR
SECTION 2
T.O.P : +65'-2"
SHOP DRAWINGS)
SUMP PUMP
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

A-302.00
PAGE: 18 OF 32
1 5/8" 20 GA MTL STUDS AT 24" o/c MAX (16"
PARTITION NOTES
O.C. @ KITCHEN CABINET LOCATIONS)
1. WALLS AND PARTITIONS INDICATED ON THE STRUCT DWGS ARE LOAD BEARING AND STRUCTURAL. FOLLOW
FLAT TAPE AND SPACKLE CONCRETE PROVIDES STC RATING OF 50+
ADDITIONAL DETAILS AND NOTES AS MAY BE INDICATED ON STRUCT DWGS FOR SUCH LOAD BEARING WALLS AND SEE STRUCT DWGS FOR B.O. STRUCT SLAB/ SEE STRUCT DWGS FOR B.O. STRUCT SLAB/
PARTITIONS. ADDITION DETAILS STRUCTURE ABOVE ADDITION DETAILS STRUCTURE ABOVE
EXPOSED CONDITIONS (SEE
NOTE 6) (1) LAYER 5/8" GWB (SEE NOTE 3)
MICHAEL KANG
2. SEE SPECIFICATION SECTION 09260 "GYPSUM BOARD ASSEMBLIES" FOR ADDITIONAL REQUIREMENTS REGARDING
ARCHITECT, PLLC.
BRACE STUDS TO ADJACENT SUBSTRATE
GYPSUM PARTITION AND SHAFTWALL CONSTRUCTION. TOOL JOINTS TO SUIT FORM 3/8" TOOLED MORTAR TOOL JOINTS TO SUIT FORM 3/8" TOOLED MORTAR Architectural, Interior Design, Zoning & Building Code Expertise
WHERE STUD SPAN EXCEEDS 7'-0" VERT.
SCHEDULED FINISH JOINT TYP HEAD OF NON SCHEDULED FINISH JOINT TYP HEAD OF NON FINISH CEILING OR SOFFIT 37-01 Main Street, Suite #308, Flushing, NY 11354
3. PROVIDE 5/8" MOISTURE RESISTANT GYPSUM WALL BOARD IN LIEU OF STANDARD GRADE GYPSUM WALL BOARD ON LOAD BEARING PARTITIONS. LOAD BEARING PARTITIONS. michaelkangra@yahoo.com
WHERE INDICATED STRUCTURAL CONCRETE/CMU UNDERLYING
THE FACE LAYER OF ALL PARTITIONS AND SOFFITS WITH BATHROOMS, EXCEPT PROVIDE 5/8" GLASS MAT GYPSUM
SUBSTRATE PROVIDES 2 HR FIRE Tel: (718) 353-2929
WALL BOARD EN LIEU MOISTURE RESISTANT GYPSUM WALL BOARD ON THE FACE LAYER OF PARTITIONS AND SOFFITS FINISH CEILING OR SOFFIT FINISH CEILING OR SOFFIT FACE OF ADJACENT WALL, SEPARATION Fax: (718) 661-1619
SURROUNDING BATHTUBS AND SHOWERS. WHERE INDICATED WHERE INDICATED COLUMN OR PARTITION AS
8" CMU (SEE NOTE 1) 8" CMU (SEE NOTE 1) INDICATED ON PLAN
4. PROVIDE ACOUSTIC INSULATION PER SPECIFICATION SECTION 09260 "GYPSUM BOARD ASSEMBLIES" WITHIN 2 " U.O.N. ON PLAN
PARTITIONS SEPARATING APARTMENT UNITS AND WITHIN PARTITIONS SEPARATING APARTMENT UNITS FROM 1 LAYER 5/8" THK.
GWB. FIRE CODE 'C' SCHEDULED FLOOR FINISH SCHEDULED WALL FINISH
CORRIDORS, LAUNDRY ROOMS, REFUSE ROOMS, AND OTHER COMMON SPACES.
SCHEDULED WALL FINISH CEMENTITOUS SCHEDULED WALL FINISH CEMENTITOUS
5. 6" CMU FILL IOO% SOLID AT REFUSE CHUTE ENCLOSURE. UNDERLAYMENT WHERE UNDERLAYMENT WHERE
SCHEDULED BASE SCHEDULED SCHEDULED BASE SCHEDULED SCHEDULED FLOOR FINISH
6. PROVIDE 5/8" HIGH IMPACT GYPSUM WALL BOARD WITH A TESTED RATING OF ASTM C 1629-06 AND IMPACT
CLASSIFICATION LEVEL 2 IN LIEU OF STANDARD GRADE GYPSUM WALL BOARD ON THE FACE LAYER OF ALL PARTITIONS SEE STRUCT DWGS FOR FLOOR SLAB SEE STRUCT DWGS FOR FLOOR SLAB
AND SOFFITS WITHIN EGRESS STAIRS AND ON FIRST LAYER ATTACHED TO STUD ON CORRIDOR/APARTMENT SIDE OF ADDITIONAL DETAILS ADDITIONAL DETAILS
STAIR. ALL STUDS SHALL BE A MINIMUM OF 3-1/2" DEEP WITH A 20 GAUGE THICKNESS AND VERTICAL STUDS SHALL BE
SPACED AT A MAXIMUM 24" ON CENTER. JOINTS BETWEEN ADJOINING SHEETS OF WALL BOARD SHALL BE STAGGERED
FROM BASE LAYER WITH FACE PANEL LAYER.

7.PROVIDE CONTINUOUS FIRE SEALANT AT FIRE RATED PARTITIONS ONLY


TYPE G: FURRING WALL @ 8" CMU ON ONE SIDE THREE HOUR FIRE RATING - UL U904 USING BLOCK D-2; MEA # 1-74 M TYPE F: 8" CMU THREE HOUR FIRE RATING - UL U904 USING BLOCK D-2; MEA # 1-74 M TYPE E: TWO HOUR FIRE RATED
TYPE G1: FURRING WALL @ 8" CMU ON BOTH SIDES THREE HOUR FIRE RATING - UL U904 USING BLOCK D-2; MEA # 1-74 M
STC RATING: 50+ RATING PROVIDED BY CONCRETE UNDERLYING SUBSTRATE
STC RATING: N/A STC RATING: N/A

FURRED CMU WALL FURRED CMU WALL FURRED GWB FINISH @ INTERIOR
G SCALE: 1 1/2" = 1'-0" F SCALE: 1 1/2" = 1'-0" E SCALE: 1 1/2" = 1'-0"

FIRE SEALANT (SEE NOTE 7)


FIRE SEALANT (SEE NOTE 7) FIRE SEALANT (SEE NOTE 7) FIRE SEALANT (SEE NOTE 7) FIRE SEALANT (SEE NOTE 7) FIRE SEALANT (SEE NOTE 7)
CONT MTL STUD RUNNERS
TOP AND BOTTOM
FLAT TAPE AND SPACKLE B.O. STRUCT SLAB/ CONT MTL STUD RUNNER TOP B.O. STRUCT SLAB/ CONT MTL STUD RUNNER TOP B.O. STRUCT SLAB/
EXPOSED CONDITIONS STRUCTURE ABOVE AND BOTTOM STRUCTURE ABOVE AND BOTTOM STRUCTURE ABOVE

MTL SHAFTWALL J RUNNER 2 1/2" 20 GA MTL STUDS AT 24"


FINISH CEILING OR SOFFIT CONT TOP AND BOTTOM (2) LAYER 5/8" GWB EACH FLAT TAPE AND SPACKLE o/c MAX (16" O.C. @ KITCHEN FLAT TAPE AND SPACKLE 2 1/2" 20 GA MTL STUDS AT 24" FLAT TAPE AND SPACKLE
WHERE INDICATED TYP FACE (SEE NOTE 3) EXPOSED CONDITIONS CABINET LOCATIONS) EXPOSED CONDITIONS o/c MAX (16" O.C. @ KITCHEN EXPOSED CONDITIONS
CABINET LOCATIONS)
S H A F T W A Y

(2) LAYERS 5/8" GWB EACH 1" GYP SHAFTWALL LINER 1 5/8" 20 GA MTL STUDS AT (2) LAYERS 5/8" GWB EACH FACE
FACE (SEE NOTE 3) PANEL 16" o/c MAX (SEE NOTE 3) (1) LAYER 5/8" GWB EACH FACE
FINISH CEILING OR SOFFIT FINISH CEILING OR SOFFIT (SEE NOTE 3) FINISH CEILING OR SOFFIT
SCHEDULED FLOOR FINISH 2 1/2" CH STUDS AT 24" o/c ACOUSTIC INSULATION (SEE WHERE INDICATED WHERE INDICATED WHERE INDICATED
6""
MAX NOTE 4)
SEE PLAN 6" 4"
CEMENTITOUS CROSS BRACE AS REQ'D ACOUSTIC INSULATION (SEE ACOUSTIC INSULATION (SEE
UNDERLAYMENT WHERE SCHEDULED FLOOR FINISH AND AT 32" o/c MAX HORIZ SCHEDULED FLOOR FINISH NOTE 4) SCHEDULED FLOOR FINISH NOTE 4) A1
SCHEDULED ACOUSTIC INSULATION (SEE WHERE VERT STUD SPAN >
NOTE 4) CEMENTITOUS 7'-0" SCHEDULED WALL FINISH SCHEDULED WALL FINISH
FLOOR SLAB UNDERLAYMENT WHERE CEMENTITOUS UNDERLAYMENT CEMENTITOUS
SCHEDULED SCHEDULED WALL FINISH WHERE SCHEDULED SCHEDULED BASE UNDERLAYMENT WHERE SCHEDULED BASE
SCHEDULED
FLOOR SLAB SCHEDULED BASE FLOOR SLAB CONT MTL STUD RUNNER CONT MTL STUD RUNNER
TOP AND BOTTOM FLOOR SLAB TOP AND BOTTOM
5" TYP FIRE SEALANT (SEE NOTE 7) FIRE SEALANT (SEE NOTE 7) FIRE SEALANT (SEE NOTE 7) FIRE SEALANT (SEE NOTE 7) FIRE SEALANT (SEE NOTE 7) FIRE SEALANT (SEE NOTE 7)

TYPE D: TWO HOUR FIRE RATED - UL U415 TYPE C: TWO HOUR FIRE RATING - UL U420 TYPE B: TWO HOUR FIRE RATING - UL U419 TYPE A: 1 HR FIRE RATED
TYPE A1: 1 HR FIRE RATED WITH WITH SOUND ATTENUATION INSULATION
STC RATING: 56
STC RATING: 51 WITH INSULATION STC RATING: 55 STC RATING: 47

GYP SHAFTWALL CHASE WALL GWB PARTITION GWB PARTITION


D SCALE: 1 1/2" = 1'-0"
C SCALE: 1 1/2" = 1'-0"
B SCALE: 1 1/2" = 1'-0"
A A1 SCALE: 1 1/2" = 1'-0"

ABBREVIATIONS
FLOOR WALL CEILING
CP CARPET
REV.# DATE DESCRIPTION
C.BLK. CONCRETE BLOCK
FLOOR ROOM MATERIAL BASE MATERIAL FINISH MATERIAL FINISH HEIGHT
CONC. CONCRETE KEY PLAN
CONC. VCT VINYL GYP. PTD C.T. CERAMIC TILE
STAIRS GYP. PTD VARIES
GYP. GYPSUM BOARD
UTILITY ROOMS CONC. - C.BLK PTD GYP. PTD 8'-0"
MARB MARBLE
COMPACTOR RM CONC. - C.BLK PTD GYP. PTD 8'-0" N
PTD PAINTED
BICYCLE ROOM CONC. - C.BLK PTD GYP. PTD 8'-0" WD WOOD
SHEET VINYL/
VCT FLOOR TILE CARPET
GRANITE VINYL C.BLK GYP. PTD GYP. PTD 8'-0" VCT VINYL COMPOSITION TILE
BREAKFAST AREA
VWC VINYL WALL COVERING

CELLAR
EDGE METAL
FLOOR TILE
CARPET PANTRY GRANITE VINYL C.BLK GYP. PTD C.T. GYP. PTD 8'-0"
SHEET VINYL/VCT TILE (SEE FINISH INDEX FOR FINISH)
SEALED TILE PUBLIC BATHROOM GRANITE VINYL GYP. MARB GYP. PTD 8'-0"
CONCRETE FLOOR CONCRETE FLOOR
CORRIDOR C.P. GRANITE GYP. VWC GYP. PTD 8'-0"
TRANSITION STRIP TRANSITION STRIP
GUEST ROOM C.P. GRANITE GYP. VWC GYP. PTD 8'-7"
FINISH NOTES:
THIN SET - ALLOW 1/4" to 1/2" BED FOR TILE BATHROOM GRANITE GRANITE GYP. MARB. GYP. PTD 8'-0" 1) MOISTURE RESISTANT GYPSUM BOARD ON WALLS AND CEILINGS.
GAUGE VARIATION CONC. VCT VINYL GYP. PTD
STAIRS GYP. VWC VARIES
LOBBY GYP. PTD 2) ALL ELECTRICAL OUTLET BOXES ARE TO BE ATTACHED TO STUDS,
GRANITE GRANITE GYP. VWC 13'-7"
CEMENTITIOUS UNDERLAYMENT LEVEL TO 1/8" AND SHOWER. PROJECT
BELOW EDGE METAL RECEPTION GRANITE GRANITE GYP. VWC GYP. PTD 13'-7"
RPZ ROOM GYP. PTD 4) WALL VINYL IS OPTIONAL.
CONC. - GYP. PTD 13'-7"
1668 EASTERN PARKWAY
1ST FLOOR

OFFICE GRANITE GRANITE GYP. VWC GYP. PTD 13'-7" 5) CARPET IS OPTION
CORRIDOR C.P. GRANITE GYP. VWC GYP. PTD 8'-0" BROOKLYN, NEW YORK
GUEST ROOM C.P. GRANITE GYP. VWC GYP. PTD 8'-7"
BATHROOM GRANITE GRANITE GYP. MARB. GYP. PTD 8'-0"
STAIRS CONC. VCT VINYL GYP. PTD GYP. PTD VARIES
PARTITION TYPES
2ND FLOOR

CORRIDOR C.P. GRANITE GYP. VWC GYP. PTD 8'-0" FINISH SCHEDULE
GUEST ROOM C.P. GRANITE GYP. VWC GYP. PTD 8'-7"
SEAL & SIGNATURE: DATE: 04-20-16
BATHROOM GRANITE GRANITE GYP. MARB. GYP. PTD 8'-0"
PROJECT No: 201601
STAIRS CONC. VCT VINYL GYP. PTD
GYP. PTD VARIES
TILE/VCT TRANSITION CONCRETE/CARPET TRANSITION CONCRETE/TRANSITION TRANSITION DRAWING BY: CC
3RD-6TH FLOOR

3 N.T.S 2 N.T.S N.T.S


CORRIDOR C.P. GRANITE GYP. VWC GYP. PTD 8'-0" CHK BY: M Kang
MECHANICAL ROOM CONC. - C.BLK PTD GYP. PTD 8'-0" DWG No:
GUEST ROOM C.P. GRANITE GYP. VWC GYP. PTD 8'-7"
BATHROOM
STAIR
GRANITE
CONC. VCT
GRANITE GYP. MARB. GYP.
GYP.
PTD 8'-0" A-401.00
VINYL GYP. PTD PTD VARIES
ROOF

MECH ROOM CONC. - C.BLK PTD GYP. PTD 8'-0" PAGE: 19 OF 32


ELEVATOR MACHINE ROOM CONC. - C.BLK PTD GYP. PTD 8'-0"
MICHAEL KANG
7'-0" 9'-7" 6'-0" 21'-7" ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3" 3"
2'-6" 3'-9" 2'-6" 6'-4" 3'-0" 2'-3" 2'-8" 5'-10" 2'-10" 2'-10" 2'-10" 2'-10" 37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

3"

3"

3"

3"
Tel: (718) 353-2929
Fax: (718) 661-1619
CASEMENT WINDOW CASEMENT WINDOW
FIXED GLASS PANEL

3'-10"

5'-0"
FIXED GLASS PANEL FIXED GLASS PANEL

5'-7"
5'-4"

5'-4"

5'-4"
FIXED GLASS PANEL

3"
11'-10"

11'-10"

11'-10"

11'-8"
3"

3"

3'-0"
3" 1'-6" 3"
3"
12'-10"

12'-10"
FIXED GLASS PANEL AUTOMATIC SLIDING DLOOR
1'-6"

1'-6"
FIXED GLASS PANEL FIXED GLASS PANEL
3"

3"

3"
SPANDREL GLASS SPANDREL GLASS
2'-0"

2'-0"
+74.0' +74.0' FIXED GLASS PANEL
SPANDREL GLASS

7'-10"
7'-0"

3'-10"
4'-0"
1ST FLOOR 1ST FLOOR
3"

3"
GLASS DOOR FIXED GLASS PANEL
1'-9"

1'-9"
GLASS DOOR AUTOMATIC SLIDING DLOOR AUTOMATIC SLIDING DLOOR
3"

3"

3"
3"
3"
NOTES:
NOTES: NOTES: NOTES: LOW-E
CW4(CELLAR) CW4 (1ST FL) LOW-E CW3(CELLAR) CW3(1ST FL) LOW-E CW2 LOW-E CW1 U-FACTOR = 0.28
CW4 CW3
U-FACTOR = 0.28 U-FACTOR = 0.28 LIGHT AREA 61 SF U-FACTOR = 0.28 LIGHT AREA 218 SF SHGC = 0.33
LIGHT AREA 54 SF 11 SF 43 SF SHGC = 0.33 LIGHT AREA 76 SF 16 SF 60 SF SHGC = 0.33 AIR AREA 28 SF SHGC = 0.33 AIR AREA 47 SF AIR INFILTRATION = 0.01
AIR AREA 13 SF - 13 SF AIR INFILTRATION = 0.01 AIR AREA 13 SF - 13 SF AIR INFILTRATION = 0.01 AIR INFILTRATION = 0.01

CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW


CW4 SCALE: 1/4" = 1'-0"
CW3 SCALE: 1/4" = 1'-0"
CW2 SCALE: 1/4" = 1'-0"
CW1 SCALE: 1/4" = 1'-0"

W1A
9'-0"
4'-0" 7'-0" 9'-0" W1
7'-0"

WINDOW NOTES: 3"


3'-6"
3" 3"
2'-6"
3"
3'-9"
3"
3"
5'-9"
3"
2'-6"
3" 3"
2'-6"
3"
VAIRES
3"

3"

3"

3"

3"
1) VERIFY ALL ROUGH OPENING DIMENSIONS AS REQUIRED TO MATCH

EQ.
FIXED WINDOW
DOOR & WINDOW SIZES SHOWN.

5'-0"
3"
CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW

5'-2"
5'-8"

5'-11"

5'-11"
2) ALL STOREFRONT & WINDOWS LOCATED ON EXTERIOR WALLS SHALL

EQ.

8'-2"

8'-2"
HAVE INSULATING GLAZING. SLIDING WINOW FIXED WINDOW FIXED GLASS PANEL FIXED GLASS PANEL

3"

3"
3) GUEST ROOM WINDOWS REQUIRED TO BE OPERABLE W/ INTEGRAL STOPS

3" 1'-6" 3"

3" 1'-6" 3"


4) OPERABLE WINDOWS SHALL HAVE SCREENS BY MFR. - TYPICAL FIXED GLASS PANEL FIXED GLASS PANEL

5) T = TEMPERED GLAZING and PER CODE REQUIREMENTS


NOTES: NOTES: NOTES: NOTES:
LOW-E LOW-E LOW-E LOW-E
6) TYPE "Q" & "R" ARE AUTOMATIC SLIDING ENTRY DOOR OPTIONS FOR W4 U-FACTOR = 0.28
W3 U-FACTOR = 0.28
W2 U-FACTOR = 0.28
W1 W1A
U-FACTOR = 0.28
"N" & "P" SWING DOORS. LIGHT AREA 15 SF SHGC = 0.28 LIGHT AREA 32 SF SHGC = 0.28 LIGHT AREA 61 SF SHGC = 0.28 LIGHT AREA 46 SF 61 SF SHGC = 0.28
AIR AREA 7.5 SF AIR INFILTRATION = 0.07 AIR AREA 13 SF AIR INFILTRATION = 0.07 AIR AREA 15 SF AIR INFILTRATION = 0.07 AIR AREA 15 SF 15 SF AIR INFILTRATION = 0.07

DOUBLE-HUNG WINDOW CASEMENT WINDOW CASEMENT WINDOW CASEMENT WINDOW


W4 SCALE: 1/4" = 1'-0"
W3 SCALE: 1/4" = 1'-0"
W2 SCALE: 1/4" = 1'-0"
W1 SCALE: 1/4" = 1'-0"

REV.# DATE DESCRIPTION

KEY PLAN

PROJECT

1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

WINDOW TYPES

SEAL & SIGNATURE: DATE: 04-20-16


PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

03 JAMB DETAIL 02 HEAD / SILL 01 WINDOW FLASHING DETAIL


A-402.00
PAGE: 20 OF 32
DOOR SCHEDULE
DOOR TYPICAL NOMINAL NOMINAL DOOR FRAME JAMB HEAD SILL HARDWARE FIRE
TAG ROOM/SPACE WIDTH HEIGHT TYPE TYPE DETAIL DETAIL DETAIL SET RATING NOTES MICHAEL KANG
ARCHITECT, PLLC.
1 GUESTROOM 2'-10" 7'-0" A A J1 H1 S8 - 2 HR Architectural, Interior Design, Zoning & Building Code Expertise

1A GUESTROOM (ADA) 3'-0" 7'-0" A A J1 H1 S8 - 2 HR 37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

2 BATHROOM DOORS 2'-8" 7'-0" B B J3 H3 S4 - UNRATED Tel: (718) 353-2929


Fax: (718) 661-1619

2A BATHROOM DOORS (ADA) 3'-0" 7'-0" B B J3 H3 S4 - UNRATED


3 CLOSETS (DOUBLE DRS) 3'-0" 7'-0" C B J3 H3 S2 - UNRATED
4 OFFICE 3'-0" 7'-0" D A J1 H1 S5 - UNRATED
5 PUBLIC BATHROOM 3'-0" 7'-0" D A J1 H1 S2 - UNRATED
6 MECH/RPZ/UTILITY ROOMS 3'-0" 7'-0" E A J1 H1 S1 - 2 HR
7 STAIR ENTRIES 3'-0" 7'-0" D A J2 H2 S1 - 2 HR

PER PER PER PER


SCHEDULED FRAME 5" 5" SCHEDULED FRAME SCHEDULED FRAME SCHEDULED FRAME SCHEDULED WIDTH SCHEDULED WIDTH
DOOR CHIME DOOR CHIME
W/ INTER-
VIEWER VIEWER
TO SUIT SCHEDULED FRAME & SILL DETAIL

TO SUIT SCHEDULED FRAME & SILL DETAIL

TO SUIT SCHEDULED FRAME & SILL DETAIL

TO SUIT SCHEDULED FRAME & SILL DETAIL

TO SUIT SCHEDULED FRAME & SILL DETAIL


SEE SCHEDULED SEE SCHEDULED
HEAD DETAIL HEAD DETAIL

1'-8"

SCHEDULED HEIGHT

SCHEDULED HEIGHT
SEE SCHEDULED SEE SCHEDULED
JAMB DETAIL JAMB DETAIL
1/4" WIRED
GLASS LITE
W/ FLUSH TRIM
4'-0"

SEE SCHEDULED SEE SCHEDULED


SILL DETAIL SILL DETAIL

PAINTED 1 3/4" H.M. PAINTED 1 3/4" H.M. PAINTED 1 3/4" SOLID CORE PAINTED 1 3/4" H.M. PAINTED WOOD FRAME PAINTED HOLLOW MTL FRAME
FLUSH DOOR FLUSH DOOR WOOD FLUSH DOOR FLUSH DOOR

DOOR TYPE E DOOR TYPE D DOOR TYPE C DOOR TYPE B DOOR TYPE A FRAME TYPE B FRAME TYPE A

GENERAL NOTES:

1. REFER TO PLANS FOR ACTUAL SWING DIRECTION. DOOR TYPE FRAME TYPE
2 N.T.S 1 N.T.S

VARIES WITH CMU PARTITION AS PER VARIES WITH


VARIES WITH VARIES WITH
PARTITION TYPE PARTITION TYPE INDICATED. PARTITION TYPE
PARTITION TYPE PARTITION TYPE
221" VARIES WITH VARIES WITH
PARTITION TYPE 221" PARTITION TYPE
GWB PARTITION. WALL MORTAR SOLID UNITS GWB PARTITION. WALL BOARD
BOARD LAYERS AND REV.# DATE DESCRIPTION
SEATED ON LINTEL GWB PARTITION. WALL BOARD LAYERS AND FRAMING VARY GWB PARTITION. WALL BOARD
FRAMING VARY PER (2) L 4" X 3" X 3/8" STRL LAYERS AND FRAMING VARY 3 3 PER PARTITION TYPE CMU PARTITION PER PARTITON LAYERS AND FRAMING VARY PER
PARTITION TYPE INDICATED. LINTEL ANGLES LLV. LOCATE PER PARTION TYPE INDICATED. 4" 4" INDICATED. TYPE INDICATED. KEY PLAN
1 PARTION TYPE INDICATED.
2" FURRED GWB FINISH PER
WALL COURSING

1 TO SUIT COURSING AT HEAD FINISH AS SCHEDULED


2"
VARIES WITH

FINISH AS SCHEDULED OF FRAME FINISH AS SCHEDULED PARTITION TYPE


3 3 MTL STUD SCHEDULED BASE BELOW DOUBLE STUD FRAMING TYP ALL
4" 4"
1 1 ADJUSTIBLE STRAP AND FLOOR
MTL STUD FRAMING AS FURRED GWB FINISH PER 2" 2" MTL STUD FRAMING AS REQ'D 1 1 1
2" ANCHORS AS REQ'D 2" 2" JAMBS N

ALIGN
REQ'D PARTITION TYP
2"

SHIM SPACE BLOCKING


HOLLOW MTL FRAME. MAT'L AND HOLLOW MTL FRAME. MAT'L HOLLOW MTL FRAME. MAT'L AND
PTD WD TRIM SEE FINISH HOLLOW MTL FRAME. MAT'L PTD WD TRIM SEE FINISH
4"

AND FINISH AS INDICATED FINISH AS INDICATED


3

FINISH AS INDICATED
2"

SCHEDULE AND FINISH AS INDICATED


2"

EQ EQ SCHEDULE

2"
CONT MORTAR GUARD
4"

4"
1

1
PTD WD FRAME SEE FINISH MORTAR SOLID TYP SUPPLIED WITH FRAME

4"
ANCHORS HEAD WHERE REQ'D PTD WD FRAME SEE FINISH FLOOR AND JAMB ANCHORS AS

3
SCHEDULE EQ EQ SCHEDULE EQ EQ EQ
MORTAR SOLID TYP REQ'D
4"

SCHEDULED DOOR. MAT'L, SCHEDULED DOOR. MAT'L,


3
2"

2"
1

SCHEDULED WD DR FINISH, SWING AND THICKNESS 1 SCHEDULED WD DR SCHEDULED DOOR. MAT'L, FINISH,
FINISH, SWING AND THICKNESS SCHEDULED DOOR. MAT'L, FINISH,
VARY AS INDICATED VARY AS INDICATED SWING AND THICKNESS VARY AS SWING AND THICKNESS VARY AS
MIN STD TO SUIT MIN STD TO SUIT MIN STD TO SUIT MIN STD TO SUIT MIN STD TO SUIT MIN STD TO SUIT
INDICATED INDICATED
SCHEDULED DOOR SCHEDULED DOOR SCHEDULED DOOR 1" SCHEDULED DOOR SCHEDULED DOOR SCHEDULED DOOR
DOOR HEAD
1"
DETAIL DOOR HEAD DETAIL DOOR HEAD DETAIL DOOR JAMB DETAIL DOOR JAMB DETAIL DOOR JAMB DETAIL
H3 SCALE: 1 1/2" = 1'-0"
H2 SCALE: 1 1/2" = 1'-0"
H1 SCALE: 1 1/2" = 1'-0"
J3 SCALE: 1 1/2" = 1'-0"
J2 SCALE: 1 1/2" = 1'-0" J1 SCALE: 1 1/2" = 1'-0"

PROJECT
NOM (CEMENTITIOUS UNDERLAYMENT)
NOM CEMENTITIOUS UNDERLAYMENT

NOM SCHEDULED STONE FLOORING


NOM CEMENTITIOUS UNDERLAYMENT

1668 EASTERN PARKWAY


NOM SCHEDULED WOOD FLOORING

NOM SCHEDULED WOOD FLOORING

NOM SCHEDULED CARPET FINISH


CARPET FINISH

NOM RESILIENT UNDERLAYMENT

NOM RESILIENT UNDERLAYMENT

NOM SCHEDULED CERAMIC TILE


BROOKLYN, NEW YORK
SCHEDULED SCHEDULED
DOOR AND DOOR AND
SCHEDULED

NOM SETTING BED


2" NOM SCHEDULED

FRAME FRAME
DOOR AND DOOR TYPES
UNDERCUT
UNDERCUT

NOM (UNDERCUT)
MAX. RISE

3 FRAME SCHEDULED DOOR


UNDERCUT

4" SINGLE BEVEL


UNDERCUT

UNDERCUT
MAX.

3 STONE SADDLE TO AND FRAME


4" EXTRUDED SCHEDULED
4" BEVEL

3 STONE 3 MATCH ADJACENT ALUM HALF DOOR AND


4" 4" CONC.
2"
2"
1
1
2"

SADDLE STONE FINISH


2"
1

FRAME
1

SADDLE AS SEAL & SIGNATURE: DATE: 04-20-16


FLOOR SLAB
2"
2"

FLOOR.
2"
1
2"
2"

4"

4"
1
1

SCHEDULED
1

2"
141"

4"
4"
1
1

2"
4"

1
4"

1
1
PROJECT No: 201601
1
1

EXTRUDED ALUM HALF

2"
1
SADDLE AS DRAWING BY: CC
SCHEDULED CHK BY: M Kang
THIN SET THIN SET
DWG No:
FLOOR
FLOOR SLAB CONC FLOOR SLAB
SLAB FLOOR SLAB

SILL DETAIL @ GUEST ROOM ENTRY DOORS SILL DETAIL @ BATHROOM DOORS SILL DETAIL @ EXIT STAIRS/CORRIDORS SILL DETAIL @ CELLAR TOILET RM SILL DETAIL @ UNFINISH FLOOR SLAB A-403.00
S5 SCALE: 1 1/2" = 1'-0"
S4 SCALE: 1 1/2" = 1'-0" S3 SCALE: 1 1/2" = 1'-0"
S2 SCALE: 1 1/2" = 1'-0"
S1 SCALE: 1 1/2" = 1'-0"

PAGE: 21 OF 32
MICHAEL KANG
ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619

REV.# DATE DESCRIPTION

KEY PLAN

PROJECT

1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

ENERGY COMPLIANCE
COMCHECK
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

EN-001.00
PAGE: 22 OF 32
REQUIREMENTS WILL BE MET MICHAEL KANG
REFER TO EN-101
ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
REQUIREMENTS WILL BE MET
REQUIREMENTS WILL BE MET 37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


REQUIREMENTS WILL BE MET
Fax: (718) 661-1619
REQUIREMENTS WILL BE MET

REQUIREMENTS WILL BE MET

REQUIREMENTS WILL BE MET

REQUIREMENTS WILL BE MET

REQUIREMENTS WILL BE MET


REQUIREMENTS WILL BE MET

REQUIREMENTS WILL BE MET

REQUIREMENTS WILL BE MET

REQUIREMENTS WILL BE MET

REV.# DATE DESCRIPTION

KEY PLAN

PROJECT

1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

ENERGY COMPLIANCE
COM-CHECK
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

EN-002.00
PAGE: 23 OF 32
TABLE II - PROGRESS INSPECTIONS FOR ENERGY CODE COMPLIANCE COMMERCIAL BUILDINGS (1 RCNY
NYCECC) TABLE II - PROGRESS INSPECTIONS FOR ENERGY CODE COMPLIANCE
THIS INSPECTION MICHAEL KANG
REQUIRED
ARCHITECT, PLLC.
REFERENCE STANDARD Architectural, Interior Design, Zoning & Building Code Expertise
ECC OR OTHER CITATION
(SEE ECC CHAPTER 6 37-01 Main Street, Suite #308, Flushing, NY 11354
FREQUENCY
INSPECTION/TEST michaelkangra@yahoo.com
IIA ENVELOPE INSPECTIONS YES NO (MINIMUM) OR OTHER CRITERIA)
PROTECTION OF EXPOSED FOUNDATION INSULATION: AS REQUIRED DURING FOUNDATION APPROVED CONSTRUCTION DOCUMENTS C303.2.1; ASHRAE 90.1 - Tel: (718) 353-2929
INSULATION SHALL BE VISUALLY INSPECTED TO VERIFY WORK AND PRIOR TO BACKFILL 5.8.1.7 IIB Fax: (718) 661-1619
MECHANICAL AND SERVICE WATER HEATING INSPECTIONS YES NO
PROPER PROTECTION WHERE APPLIED TO THE EXTERIOR
OF BASEMENT OR CELLAR WALLS, CRAWL-SPACE WALLS
AND/OR THE PERIMETER OF SLAB-ON-GRADE FLOORS.
FIRE PLACES: PROVISION OF COMBUSTION AIR AND TIGHT-FITTING FIRE
IIB1 PLACE DOORS SHALL BE VERIFIED BY VISUAL INSPECTION

IIA2 INSULATION PLACEMENT AND R-VALUES: INSTALLED AS REQUIRED TO VERIFY CONTINUOUS APPROVED CONSTRUCTION DOCUMENTS C303.1, C303.1.1,
INSULATION FOR EACH COMPONENT OF THE CONDITIONED ENCLOSURE WHILE WALLS, CEILINGS C303.1.2, C402.1,
OUTDOOR AIR INTAKES AND EXHAUST OPENINGS: DAMPERS FOR STAIR AND AS REQUIRED DURING APPROVED CONSTRUCTION
SPACE ENVELOPE AND AT JUNCTIONS BETWEEN AND FLOORS ARE OPEN C402.2; ASHRAE 90.1 - 5.5, 5.6 402.4.4;
COMPONENTS SHALL BE VISUALLY INSPECTED TO ENSURE OR 11; 5.8.1 IIB2 ELEVATOR SHAFT VENTS AND OTHER OUTDOOR AIR INTAKES AND EXHAUST INSTALLATION DOCUMENTS; AMCA 500D
THAT THE R-VALUES ARE MARKED, THAT SUCH R-VALUES OPENINGS INTEGRAL TO THE BUILDING ENVELOPE SHALL BE VISUALLY INSPECTED ASHRAE
CONFORM TO THE R-VALUES IDENTIFIED IN THE
TO VERIFY THAT SUCH DAMPERS, EXCEPT WHERE PERMITTED TO BE GRAVITY 90.1-
CONSTRUCTION DOCUMENTS AND THAT THE INSULATION 6.4.3.4
IS PROPERLY INSTALLED. CERTIFICATIONS FOR UNMARKED DAMPERS, COMPLY WITH APPROVED CONSTRUCTION DRAWINGS.MANUFACTURER'S
INSULATION SHALL BE SIMILARLY VISUALLY INSPECTED. LITERATURE SHALL BE REVIEWED TO VERIFY THAT THE PRODUCT HAS BEEN TESTED
AND FOUND TO MEET THE STANDARD.

HVAC, SERVICE WATER HEATING AND POOL EQUIPMENT SIZING AND PERFORMANCE: PRIOR TO FINAL APPROVED 403.2, 404.2, 404.7; ASHRAE
IIA3 FENESTRATION U-FACTOR AND PRODUCT RATINGS: AS REQUIRED DURING INSTALLATION APPROVED CONSTRUCTION DRAWINGS; C303.1, C303.1.3, IIB3 EQUIPMENT SIZING, EFFICIENCIES AND OTHER PERFORMANCE FACTORS OF ALL 90.1-6.3, 6.4.1, 6.4.2,
U-FACTORS, SHGC AND VT VALUES OF INSTALLED NFRC 100, NFRC 200 C402.3; ASHRAE 90.1 - 5.5; 5.6 PLUMBING AND CONSTRUCTION
FENESTRATION SHALL BE VISUALLY INSPECTED FOR OR 11; 5.8.2 MAJOR EQUIPMENT UNITS, AS DETERMINED BY THE APPLICANT OF RECORD, AND CONSTRUCTION DOCUMENTS 6.8;7.4, 7.8
CONFORMANCE WITH THE U-FACTORS, SHGC AND VT
VALUES IDENTIFIED IN THE CONSTRUCTION DRAWINGS BY
NO LESS THAN 15% OF MINOR EQUIPMENT UNITS, SHALL BE VERIFIED BY VISUAL INSPECTION
VERIFYING THE MANUFACTURER'S NFRC LABELS OR, INSPECTION AND, WHERE NECESSARY, REVIEW OF MANUFACTURER'S DATA. POOL
WHERE NOT LABELED, USING THE RATINGS IN ECC TABLES HEATERS AND COVERS SHALL BE VERIFIED BY VISUAL INSPECTION.
C303.1.3(1), (2) AND (3).

HVAC SYSTEM CONTROLS AND ECONOMIZERS AND SERVICE HOT WATER SYSTEM CONTROLS: NO AFTER INSTALLATION AND PRIOR TO APPROVED CONSTRUCTION 403.2.4, 403.2.5.1, 403.2.11,
IIA4 FENESTRATION AIR LEAKAGE: WINDOWS, SKYLIGHTS AND AS REQUIRED DURING INSTALLATION; NFRC 400, AAMA/WDMA/CSA 101/ I.S.2/A400 C402.3; ASHRAE 90.1 - 5.4.3.2 LESS THAN 20% OF EACH TYPE OF REQUIRED CONTROLS AND ECONOMIZERS SHALL BE FINAL ELECTRICAL AND DOCUMENTS, INCLUDING 403.3, 403.4, 404.3, 404.6,
SLIDING OR SWINGING DOOR ASSEMBLIES, EXCEPT PRIOR TO FINAL CONSTRUCTION ASTM E283; ANSI/DASMA 105 IIB4
VERIFIED BY VISUAL INSPECTION AND TESTED FOR FUNCTIONALITY AND PROPER OPERATION. CONSTRUCTION INSPECTION, EXCEPT CONTROL SYSTEM NARRATIVES; 404.7;
SIT-BUILT WINDOWS AND/ OR DOORS, SHALL BE VISUALLY INSPECTION
INSPECTED TO VERIFY THAT INSTALLED ASSEMBLIES ARE SUCH CONTROLS SHALL INCLUDE, BUT ARE NOT LIMITED TO THERMOSTATIC, SET POINT THAT FOR CONTROL WITH ASHRAE GUIDELINE1: THE HVAC ASHRAE 90.1- 6.3, 6.4, 6.5,
LISTED AND LABELED BY THE MANUFACTURER TO THE OVERLAP RESTRICTION, OFF-JOUR, SHUTOFF DAMPER, SNOW-MELT SYSTEM, DEMAND CONTROL SEASONALLY DEPENDENT COMMISSIONING PROCESS WHERE 6.7.2.4, 7.4.4, 7.4.5
REFERENCED STANDARD. .
SYSTEMS, OUTDOOR HEATING SYSTEMS, ZONES, ECONOMIZERS, AIR SYSTEMS, VARIABLE AIR FUNCTIONALITY, SUCH TESTING APPLICABLE
FOR CURTAIN WALL, STOREFRONT GLAZING, COMMERCIAL
ENTRANCE DOORS AND REVOLVING DOORS, THE TESTING VOLUME FAN, HYDRONIC SYSTEMS, HEAT REJECTION EQUIPMENT FAN SPEED. COMPLEX SHALL BE PERFORMED BEFORE
REPORTS SHALL BE REVIEWED TO VERIFY THAT THE MECHANICAL SYSTEMS SERVING MULTIPLE ZONES, VENTILATION, ENERGY RECOVERY SYSTEMS, SIGH-OFF FOR ISSUANCE OF A
INSTALLED ASSEMBLY COMPLIES WITH THE STANDARD HOT GAS BYPASS LIMITATION, TEMPERATURE, SERVICE WATER HEATING, HOT WATER SYSTEM, FINAL CERTIFICATE OF OCCUPANCY
CITED IN THE APPROVED PLANS
POOL HEATER AND TIME SWITCHES, EXHAUST HOODS, RADIANT HEATING SYSTEMS. CONTROLS
WITH SEASONALLY DEPENDENT FUNCTIONALITY: CONTROLS WHOSE COMPLETE OPERATION
CANNOT BE DEMONSTRATED DUE TO PREVAILING WEATHER CONDITIONS TYPICAL OF THE
SEASON DURING WHICH PROGRESS INSPECTIONS WILL E PERFORMED SHALL BE PERMITTED TO
IIA5 FENESTRATION AREAS: DIMENSIONS OF WINDOWS, DOORS PRIOR TO FINAL CONSTRUCTION APPROVED CONSTRUCTION DOCUMENTS C402.3; ASHRAE 90.1 - 5.5.4.2,
AND SKYLIGHTS SHALL BE VERIFIED BY VISUAL INSPECTION 5.6 OR 11 BE SIGNED OFF FOR THE PURPOSE OF A TEMPORARY CERTIFICATE OF OCCUPANCY WITH ONLY
INSPECTION. A VISUAL INSPECTION, PROVIDED, HOWEVER, THAT THE PROGRESS INSPECTOR SHALL PERFORM
A SUPPLEMENTAL INSPECTION WHERE THE CONTROLS ARE VISUALLY INSPECTED AND
IIA6 AIR SEALING AND INSULATION - VISUAL INSPECTION: AS REQUIRED DURING ENVELOPE APPROVED CONSTRUCTION DOCUMENTS; C402.4; ASHRAE 90.1 - 5.4.3.1 TESTED FOR FUNCTIONALITY AND PROPER OPERATION DURING THE NEXT IMMEDIATE SEASON
OPENINGS AND PENETRATIONS IN THE BUILDING CONSTRUCTION ASTM E2178; ASTM E2357; ASTM E1677, ASTM
ENVELOPE, INCLUDING SITE-BUILT FENESTRATION AND E779, ASTM E283 THEREAFTER. THE OWNER SHALL PROVIDE FULL ACCESS TO HE PROGRESS INSPECTOR WITHIN
DOORS, SHALL BE VISUALLY INSPECTED TO VERIFY THAT A TWO WEEKS OF THE PROGRESS INSPECTOR'S REQUEST FOR SUCH ACCESS TO PERFORM THE
CONTINUOUS AIR BARRIER AROUND THE ENVELOPE
FORMS AN AIR-TIGHT ENCLOSURE. .
PROGRESS INSPECTION. FOR SUCH SUPPLEMENTAL INSPECTIONS, THE DEPARTMENT SHALL BE
THE PROGRESS INSPECTOR SHALL VISUALLY INSPECT TO NOTIFIED BY THE APPROVED PROGRESS INSPECTION AGENCY OF ANY UNRESOLVED
VERIFY THAT MATERIALS AND/ OR ASSEMBLIES HAVE BEEN DEFICIENCIES IN THE INSTALLED WORK WITHIN 180 DAYS OF SUCH SUPPLEMENTAL
TESTED AND MEET THE REQUIREMENTS OF THE
RESPECTIVE STANDARDS, OR THAT THE BUILDING IS
INSPECTION.
TESTED AND MEETS THE REQUIREMENTS OF THE
STANDARD, IN ACCORDANCE WITH THE STANDARD(S) APPROVED CONSTRUCTION
CITED IN THE APPROVED PLANS AIR LEAKAGE TESTING FOR HIGH PRESSURE DUCT SYSTEMS: FOR DUCT SYSTEMS DESIGNED TO AFTER INSTALLATION AND PRIOR 403.2.7.1.3;
OPERATE STATIC PRESSURES IN EXCESS OF 3 INCHES W.G (746 PA), REPRESENTATIVE SECTIONS, TO CLOSING SHAFTS, CEILINGS DOCUMENTS; SMACNA HVAC ASHRAE 90.1-
IIB5 AS DETERMINED BY THE PROGRESS INSPECTOR, TOTALING AT LEAST 25% OF THE DUCT AREA, PER AND WALLS AIR DUCT LEAKAGE TEST 6.4.4.2
ECC 503.7.1.3, SHALL BE TESTED TO VERIFY THAT ACTUAL AIR LEAKAGE IS BELOW ALLOWABLE MUNUAL
IIA7 PROJECTION FACTORS: WHERE THE ENERGY ANALYSIS PRIOR TO FINAL CONSTRUCTION APPROVED CONSTRUCTION DOCUMENTS, C402.3; ASHRAE 90.1 - 5.5.4, AMOUNTS.
UTILIZED A PROJECTION FACTOR > 0, THE PROJECTION INSPECTION INCLUDING ENERGY ANALYSIS 5.6 OR 11
DIMENSIONS OF OVERHANGS, EAVES OR PERMANENTLY
ATTACHED SHADING DEVICES SHALL BE VERIFIED FOR
CONFORMANCE WITH APPROVED PLANS BY VISUAL IIC ELECTRICAL POWER AND LIGHTING SYSTEMS
INSPECTION
ELECTRICAL METERING: THE PRESENCE AND OPERATION OF INDIVIDUAL METERS OR OTHER PRIOR TO FINAL ELECTRICAL AND APPROVED CONSTRUCTION 405.7
IIC1 MEANS OF MONITORING INDIVIDUAL APARTMENTS SHALL BE VERIFIED BY VISUAL INSPECTION CONSTRUCTION INSPECTION DOCUMENTS
IIA8 LOADING DOCK WEATHERSEALS: WEATHERSEALS AT PRIOR TO FINAL CONSTRUCTION APPROVED CONSTRUCTION DOCUMENTS C402.4.6; ASHRAE 90.1 - FOR AL APARTMENTS.
LOADING DOCKS SHALL BE VISUALLY VERIFIED. INSPECTION 5.4.3.3

INTERIOR LIGHTING POWER: INSTALLED LIGHTING SHALL BE VERIFIED FOR COMPLIANCE WITH PRIOR TO FINAL ELECTRICAL AND 405.5; ASHRAR 90.1-9.1, 9.2. 9.5,
IIA9 VESTIBULES: REQUIRED ENTRANCE VESTIBULES SHALL BE PRIOR TO FINAL CONSTRUCTION APPROVED CONSTRUCTION DOCUMENTS C402.4.7; ASHRAE 90.1 - APPROVED CONSTRUCTION
VISUALLY INSPECTED FOR PROPER OPERATION. INSPECTION 5.4.3.4 IIC3 THE LIGHTING POWER ALLOWANCE BY VISUAL INSPECTION OF FIXTURES, LAMPS, BALLASTS CONSTRUCTION INSPECTION
DOCUMENTS 9.6; 1RCNY &101-07(C)(3)(V)(C)4
AND TRANSFORMERS.

EXTERIOR LIGHTING: INSTALLED LIGHTING SHALL BE VERIFIED FOR COMPLIANCE WITH SOURCE PRIOR TO FINAL ELECTRICAL AND 405.6; ASHRAR 90.1-9.4.4, 9.4.5;
IIC4 APPROVED CONSTRUCTION
EFFICACY AND/OR THE LIGHTING POWER ALLOWANCE BY VISUAL INSPECTION OF FIXTURES, CONSTRUCTION INSPECTION 1RCNY &101-
DOCUMENTS
LAMPS, BALLASTS AND RELEVANT TRANSFORMERS. 07(C)(3)(V)(C)4

LIGHTING CONTROLS: EACH TYPE OF REQUIRED LIGHTING CONTROLS, INCLUDING: OCCUPANT PRIOR TO FINAL ELECTRICAL AND APPROVED CONSTRUCTION 405.2, 405.2.2.2;
IIC5 SENSORS, MANUAL INTERIOR LIGHTING CONTROLS, LIGHT-REDUCTION CONTROLS, AUTOMATIC CONSTRUCTION INSPECTION DOCUMENTS, INCLUDING ASHRAE 90.1-9.4.1, 9.4.1.2 REV.# DATE DESCRIPTION
LIGHTING LIGHTING SHUT-OFF, DAYLIGHT ZONE CONTROLS, SLEEPING UNIT CONTROLS, EXTERIOR CONTROL SYSTEM NARRATIVES (AS MODIFIED BY SECTION ECC A102)
LIGHTING CONTROLS SHALL BE VERIFIED BY VISUAL INSPECTION AND TESTED FOR FUNCTIONALITY KEY PLAN
AND PROPER OPERATION.

EXIT SIGHS: INSTALLED EXIT SIGHS SHALL BE VISUALLY INSPECTED TO VERIFY THAT THE LABEL PRIOR TO FINAL ELECTRICAL AND APPROVED CONSTRUCTION 405.4
IIC6 INDICATED THAT THEY DO NOT EXCEED MAXIMUM PERMITTED WATTAGE. CONSTRUCTION INSPECTION DOCUMENTS ASHEAE N
90.1-9.4.3

TANDEM WIRING: TANDEM WIRING SHALL BE TESTED FOR FUNCTIONALITY. PRIOR TO FINAL ELECTRICAL AND APPROVED CONSTRUCTION 405.3 ASHEAE
IIC7 CONSTRUCTION INSPECTION DOCUMENTS 90.1-9.4.2

ELECTRIC MOTORS (INCLUDING BUT NOT LIMITED TO FAN MOTORS): WHERE REQUIRED BY PRIOR TO FINAL ELECTRICAL AND 405.2.10
APPROVED CONSTRUCTION
IIC8 THE CONSTRUCTION DOCUMENTS FOR ENERGY CODE COMPLIANCE, MOTOR LISTING OR CONSTRUCTION INSPECTION ASHEAE 90.1-10.4
DOCUMENTS
LABELS SHALL BE VISUALLY INSPECTED TO VERIFY THAT THEY COMPLY WITH THE
RESPECTIVE ENERGY REQUIREMENTS IN THE CONSTRUCTION DOCUMENT.

IID OTHER

MAINTENANCE INFORMATION: MAINTENANCE MANUALS FOR MECHANICAL, SERVICE HOT PRIOR TO SIGH-OFF OR ISSUANCE APPROVED CONSTRUCTION 303.3, 403.2.9.3; PROJECT
WATER AND ELECTRICAL EQUIPMENT AND SYSTEMS REQUIRING PREVENTIVE OF FINAL CERTIFICATE OF DOCUMENTS, INCLUDING ASHRAE 90.1-4.2.2.3,
IID1 MAINTENANCE SHALL BE REVIEWED FOR APPLICABILITY TO INSTALLED EQUIPMENT AND
SYSTEMS BEFORE SUCH MANUALS ARE PROVIDED TO THE OWNER. LABELS REQUIRED
OCCUPANCY ELECTRICAL DRAWINGS WHERE
APPLICABLE; ASHRAE GUIDELINE
6.4.2.2, 8.7.2
1668 EASTERN PARKWAY
FOR SUCH EQUIPMENT OF SYSTEMS SHALL BE INSPECTED FOR ACCURACY AND 4; PREPARATION OF OPERATING
AND MAINTENANCE
BROOKLYN, NEW YORK
COMPLETENESS.
DOCUMENTATION FOR BUILDING
SYSTEMS

PROGRESS INSPECTIONS

SEAL & SIGNATURE: DATE: 04-20-16


PROJECT No: 201601
TO THE BEST OF MY KNOWLEDGE, THE PROPOSED BUILDING IN COMPLIANCE WITH 2014 NEW YORK DRAWING BY: CC
CHK BY: M Kang
CITY ENERGY CONSERVATION CODE USING CHAPTER C4 (COMMERCIAL ENERGY EFFICIENCY) DWG No:

EN-003.00
PAGE: 24 OF 32
SUPPORTING DOCUMENTATION REFERENCE:
AIR LEAKAGE NOTE
C402.4 AIR LEAKAGE (MANDATORY). ROOF TYPE: EN-001 & EN-101 TO THE BEST OF MY KNOWLEDGE, THE PROPOSED BUILDING IN
THE THERMAL ENVELOPE OF BUILDINGS SHALL COMPLY WITH SECTIONS C402.4.1 THROUGH C402.4.8.
EXTERIOR WALL TYPE: EN-001 & EN-101
C402.4.1 AIR BARRIERS
FOUNDATION TYPE:
COMPLIANCE WITH 2014 NEW YORK CITY ENERGY CONSERVATION CODE
A CONTINUOUS AIR BARRIER SHALL BE PROVIDED THROUGHOUT THE BUILDING THERMAL ENVELOPE. THE AIR BARRIERS SHALL BE PERMITTED TO BE EN-001 & EN-101
LOCATED ON THE INSIDE OR OUTSIDE OF THE BUILDING ENVELOPE, LOCATED WITHIN THE ASSEMBLIES COMPOSING THE ENVELOPE, OR
BASEMENT WALL TYPE: EN-001 & EN-101 USING CHAPTER C4 (COMMERCIAL ENERGY EFFICIENCY)
ANY COMBINATION THEREOF. THE AIR BARRIER SHALL COMPLY WITH SECTIONS C402.4.1.1 AND C402.4.1.2.
EXCEPTION: AIR BARRIERS ARE NOT REQUIRED IN BUILDINGS LOCATED IN CLIMATE ZONE 1,2 AND 3. WINDOWS: EN-102
MICHAEL KANG
C402.4.1.1. AIR BARRIER CONSTRUCTION. DOORS: EN-102 ARCHITECT, PLLC.
THE CONTINUOUS AIR BARRIER SHALL BE CONSTRUCTED TO COMPLY THE FOLLOWING: 2X4 WATER-PROOF
1. THE AIR BARRIER SHALL BE CONTINUOUS FOR ALL ASSEMBLIES THAT ARE THE THERMAL ENVELOPE OF THE BUILDING AND PROGRESS INSPECTION FOR ENVELOPE: EN-003 ALUMINIUM PANEL WOOD BLOCK @24" C.C.
Architectural, Interior Design, Zoning & Building Code Expertise
ACROSS THE JOINTS AND ASSEMBLIES. 37-01 Main Street, Suite #308, Flushing, NY 11354
2. AIR BARRIER JOINTS AND SEAMS SHALL BE SEALED, INCLUDING SEALING TRANSITIONS IN PLACES AND CHANGES IN MATERIALS. EXTERIOR WALL AREA: EN-102 WOOD STUD @ 24" C.C.
FLASHING michaelkangra@yahoo.com
AIR BARRIER PENETRATIONS SHALL BE SEALED IN ACCORDANCE WITH SECTION C402.4.2.. THE JOINTS AND
SEALS SHALL BE SECURELY INSTALLED IN OR ON THE JOINT FOR ITS ENTIRE LENGTH SO AS NOT TO DISLODGE. LOOSEN OR
WINDOW & DOOR AREA: EN-102 18 GAGE TRUSS TYPE ROOFING MEMBRANE
Tel: (718) 353-2929
OTHERWISE IMPAIR ITS ABILITY TO RESIST POSITIVE AND NEGATIVE PRESSURE FROM WIND, STACK EFFECT AND REINF. @16" O.C. 8" CMU WALL W/ #5@32" VERTICAL REINF. Fax: (718) 661-1619
MECHANICAL VENTILATION. CAULKING FILL CELLS SOLID.
3. RECESSED LIGHTING FIXTURES SHALL COMPLY WITH SECTION C402.4.8. WHERE SIMILAR OBJECTS ARE INSTALLED WHICH
PENETRATE THE AIR BARRIER, PROVISIONS SHALL BE MADE TO MAINTAIN THE INTEGRITY OF THE AIR BARRIER. LOCATION CONT. CAVITY CANT. STRIP

3'-8"
EXCEPTION: BUILDINGS THAT COMPLY WITH SECTION C402.4.1.2.3 ARE NOT REQUIRED TO COMPLY WITH ITEM 1 AND 3.
R-VALUE R-VALUE ASPHALFT ROOFING
C402.4.1.2.1 MATERIALS SLOPE 1/8" PER FT. RIGID INSULATION
MATERIALS WITH AN AIR PERMEABILITY NO GREATER THAN 0.004 CFM/SF(0.02L/S . S.M.) UNDER A PRESSURE DIFFERENTIAL OF CDS WATER PROOFING
POLYSTYRENE (XPS) R-20
0.3 INCHES WATER GAUGE(W.G.)(75PA) WHEN TESTED IN ACCORDANCE WITH ASTM E 2178 SHALL COMPLY WITH THIS SECTION. ROOF RIGID INSULATION ALUMINIUM PANEL R-VALUE = 20
MATERIALS IN ITEM 1 THROUGH 15 SHALL BE DEEMED TO COMPLY WITH THIS SECTION PROVIDED JOINTS ARE SEALED
AND MATERIALS ARE INSTALLED AS AIR BARRIERS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. POLYSTYRENE (XPS) R-20 20 3/4" STYROFOAM
1. PLYWOOD WITH A THICKNESS OF NOT LESS THAN 38 INCH (10 mm)
2. ORIENTED STRAND BOARD HAVING A THICKNESS OF NOT LESS THAN 38 INCH (10 mm) EXTERIOR WALL WALL TYPE - 1 (METAL PANEL & CMU) 13 13
3. EXTRUDED POLYSTYRENE INSULATION BOARD HAVING A THICKNESS OF NOT LESS THAN 21 INCH (12 mm)
4. FOIL-BACK POLYISOCYANURATE INSULATION BOARD HAVING THICKNESS OF NOT LESS THAN 21 INCH (12 mm) WALL TYPE - 2 (STUCCO & CMU)
5. CLOSED CELL SPRAY FOAM A MINIMUM DENSITY OF 1.5 PCF (2.4KG/C.M.) HAVING A THICKNESS OF NOT LESS THAN 1-1/2 INCH (36 mm)
7.5 13
6. OPEN CELL SPRAT FOAM WITH A DENSITY BETWEEN 0.4 AND 1.5 CFP(0.6 AND 2.4 KG/C.M.) AND HAVING A THICKNESS OF NOT LESS THAN 4.5 OMEGA LAMINATORS INC.
INCHES (36 mm) FOUNDATION WALL WALL TYPE -3 CONCRETE WALL WITH 2" THERMOLITE METAL PANEL 2 LAYERS OF GYPSUM BOARD TYPE 'X'
2 HOUR FIRE RATED CEILING
7. EXTERIOR OR INTERIOR GYPSUM BOARD HAVING A THICKNESS OF NOT LESS THAN 21 INCH (12 mm) BATT INSULATION (PLASTIC STABLIZER /
8. CEMENT BOARD HAVING A THICKNESS OF NOT LESS THAN 21 INCH (12 mm) 13 ISOCYANURATE CORE)
9. BUILT UP ROOFING MEMBRANE. R-13 CONTINUOUS INSULATION
10. MODIFIED BITUMINOUS ROOF MEMBRANE.
11. FULLY ADHERED SINGLE-PLY ROOF MEMBRANE.
R-VALUE = 13
12. A PORTLAND CEMENT/SAND PARGE, OR GYPSUM PLASTER HAVING A THICKNESS OF NOT LESS THAN 58 INCH (16 mm)
13. CAST-IN-PLACE AND PRECAST CONCRETE.
14. FULLY GROUTED CONCRETE BLOCK MASONRY.
15. SHEET STEEL OR ALUMINUM. WOOD BLOCKING

C402.4.1.2.2 ASSEMBLIES. CAVITY INSULATION


ASSEMBLIES OF MATERIALS AND COMPONENTS WITH AN AVERAGE AIR LEAKAGE NOT EXCEED 0.04 CFM/SF (0.2 L/S.SM) UNDER A PRESSURE ALUMINIUM PANEL R-13 FIBERGLASS INSULATION
DIFFERENTIAL OF 0.3 INCHES OF WATER GAUGE (W.G.)(75 PA) WHEN TESTED IN ACCORDANCE WITH ASTM E 2357, ASTM E 1677 OR ASTM E 283 COPING STONE
R-VALUE = 13
SHALL COMPLY WITH THIS SECTION. ASSEMBLIES LISTED IN ITEM 1 AND 2 SHALL BE DEEMED TO COMPLY PROVIDED JOINTS ARE SEALED FLASHING
AND REQUIREMENTS OF SECTION C402.4.1.1 ARE MET.
1. CONCRETE MASONRY WALLS COATED WITH ONE APPLICATION EITHER OF BLOCK FILLER AND TWO APPLICATIONS OF A PAINTED OR ROOFING MEMBRANE
SEALER COATING. 8" CMU WALL W/ #5@32" VERTICAL REINF.
2. A PORTLAND CEMENTS/SAND PARGE, STUCCO OR PLASTER MINIMUM 21 INCH (12 mm) IN THICKNESS. FILL CELLS SOLID.
CDS WATER
C402.4.1.2.3 BUILDING TEST CANT. STRIP PROOFING
THE COMPLETED BUILDING SHALL BE TESTED AND THE AIR LEAKAGE RATE OF THE BUILDING EVELOPE SHALL NOT EXCEED 0.40 CFM/SF AT A
PRESSURE DIFFERENTIAL OF 0.3 INCHES WATER GAUGE (2.0L/S.SM AT 75 PA) IN ACCORDANCE WITH ASTM E 779 OR AN EQUIVALENT METHOD ASPHALFT ROOFING 2 LAYERS OF GYPSUM BOARD TYPE 'X'
2 HOUR FIRE RATED CEILING
APPROVED BY THE CODE OFFICIAL. SLOPE 1/8" PER FT.
RIGID IINSULATION
C402.4.2 AIR BARRIER PENETRATIONS. POLYSTYRENE (XPS) R-20
PENETRATION OF THE AIR BARRIER AND PATHS OF AIR LEAKAGE SHALL BE CAULKED, GASKETED OR OTHERWISE SEALED IN MANNER 1" CONT. INSULATION R-VALUE = 20
COMPATIBLE WITH THE CONSTRUCTION MATERIALS AND LOCATION. JOINTS AND SEALED SHALL BE SEALED IN THE SAME MANNER OR TAPED OR POLYSTYRENE
COVERED WITH A MOISTURE VAPOR-PERMEABLE WRAPPING MATERIAL. SEALING MATERIALS SHALL BE APPROPRIATE TO THE CONSTRUCTION R-VALUE = R-7.5
MATERIALS BEING SEALED. THE JOINTS AND SEALS SHALL BE SECURELY INSTALLED IN OR ON THE JOINT FOR ITS ENTIRE LENGTH SO AS NOT TO OMEGA LAMINATORS INC.
DISLODGE, LOOSEN OR OTHERWISE IMPAIR ITS ABILITY TO RESIST POSITIVE AND NEGATIVE PRESSURE FROM WIND, STACK EFFECT AND 2" THERMOLITE METAL PANEL WOOD BLOCKING
MECHANICAL VENTILATION. (PLASTIC STABLIZER /
ISOCYANURATE CORE) CAVITY INSULATION
C402.4.3 AIR LEAKAGE OF FENESTRATION. CONTINUOUS INSULATION
THE AIR LEAKAGE OF FENESTRATION ASSEMBLIES SHALL MEET THE PROVISIONS OF TABLE C402.4.3. TESTING SHALL BE IN ACCORDANCE R-13 FIBERGLASS INSULATION
WITH THE APPLICABLE REFERENCE TEST STANDARD IN TABLE C402.4.3 BY AND ACCREDITED, INDEPENDENT TESTING LABORATORY AND R-VALUE = 13 R-VALUE = 13
LABELED BY THE MANUFACTURER.

EXCEPTIONS:
1. FIELD-FABRICATED FENESTRATION ASSEMBLIES THAT ARE SEALED IN ACCORDANCE WITH SECTION C402.4.1. ALUMINIUM PANEL
2. FENESTRATION IN BUILDINGS THAT COMPLY WITH SECTION C402.4.1.2.3 ARE NOT REQUIRED TO MEET THE AIR LEAKAGE
REQUIREMENTS IN TABLE C402.4.3.
TABLE C402.4.3.
MAXIMUM AIR INFILTRATION RATE FOR FENESTRATION ASSEMBLIES CAVITY INSULATION CDS WATER
(RIGID INSULATION) PROOFING
FENESTRATION ASSEMBLY MAXIMUM RATE
TEST PROCEDURE R-VALUE = 13
(CFM/ SF)
SURFACE RASPED
a
WINDOWS 0.20 STO. REINFORCED MESH. 8" CMU
a
SLIDING DOORS 0.20 STO. BASE COAT
a AAMA/ WDMA/ CSA101/ I,S,2/ A440 WOOD BLOCKING
SWING DOORS 0.20 OR NFRC 400 STO. PRIMER
SKYLIGHTS-WITH CONDENSATION STO. FINISH CAVITY INSULATION
WEEPAGE OPENINGS 0.30
R-13 FIBERGLASS INSULATION
a
SKYLIGHTS - ALL OTHER 0.20 2 LAYERS OF 5/8" GYP BD. TYPE 'X' CEILING R-VALUE = 13
2 HOURS FIRE RATED
CURTAIN WALLS 0.06

STOREFRONT GLAZING 0.06 ALUMINIUM PANEL


COMMERCIAL GLAZED SWINGING NFRC 400 OR ASTM E 283 AT 1.57 PSF (75 PA)
ENTRANCE DOORS 1.00 1" CONT. INSULATION
REVOLVING DOORS 1.00
POLYSTYRENE
CDS WATER
R-VALUE = R-7.5 CAVITY INSULATION PROOFING
GARAGE DOORS 0.40 ANSI / DASMA 105, (RIGID INSULATION)
NFRC 400, OR ASTM E 283 AT 1.57 PSF R-VALUE = 13
ROLLING DOORS 1.00 (75 PA)
8" CMU REV.# DATE DESCRIPTION
FOR SI: 1 CUBIC FOOT PER MINUTE = 0.47L/S, 1 SQUARE FOOT = 0.093 S/M
A THE MAXIMUM RATE FOR WINDOWS, SLIDING AND SWINGING DOORS, AND SKYLIGHTS IS PERMITTED TO BE 0.3 CFM PER SQUARE FOOT OF FENESTRATION OR DOOR AREA WHEN TESTED IN
ACCORDANCE WITH AAMA/ WDMA/ CSA 101/ I.S.2/ A440 AT 6.24 PSF (300 PA).

CAVITY INSULATION KEY PLAN


C402.4.4 DOORS AND ACCESS OPENINGS TO SHAFTS, CHUTES, STAIRWAYS, AND ELEVATOR LOBBIES. R-13 FIBERGLASS INSULATION
DOORS AND ACCESS OPENINGS FROM CONDITIONED SPACE TO SHAFTS, CHUTES, STAIRWAYS AND ELEVATOR LOBBIES SHALL EITHER MEET THE
REQUIREMENTS OF SECTION C402.4.3. OR SHALL BE GASKETED, WEATHERSTRIPPED OR SEALED. R-VALUE = 13
SURFACE RASPED
EXCEPTIONS:
DOOR OPENINGS REQUIRED TO COMPLY WITH SECTION 715 OR 715.3 OF THE NEW YORK CITY BUILDING CODE; OR STO. REINFORCED MESH. 2 LAYERS OF 5/8" GYP BD. TYPE 'X' CEILING N
DOORS AND DOOR OPENINGS REQUIRED BY THE NEW YORK CITY BUILDING CODE TO COMPLY WITH UL 1784 SHALL NOT BE 2 HOURS FIRE RATED
REQUIRED TO COMPLY WITH SECTION C402.4.4. 8" CMU
STO. BASE COAT
C402.4.5 AIR INTAKES, EXHAUST OPENINGS, STAIRWAYS AND SHAFTS. ALUMINIUM PANEL
STAIRWAY ENCLOSURES AND ELEVATOR SHAFT VENTS AND OTHER OUTDOOR AIR INTAKES AND EXHAUST OPENINGS INTEGRAL TO THE BUILDING
STO. PRIMER
ENVELOPE SHALL BE PROVIDED WITH DAMPERS IN ACCORDANCE WITH SECTION C403.2.4.4.
STO. FINISH

8"
C402.4.6 LOADING DOCK WEATHERSEALS. REINFORCED
CARGO DOORS AND LOADING DOCK DOORS SHALL BE EQUIPPED WITH WEATHERSEALS TO RESTRICT INFILTRATION WHEN VEHICLES ARE PARKED CONCRETE SLAB
IN THE DOOR WAY.

C402.4.7 VESTIBULES. CAVITY INSULATION


ALL BUILDING ENTRANCES SHALL BE PROTECTED WITH AN ENCLOSED VESTIBULE, WITH ALL DOORS OPENING INTO AND OUT OF THE VESTIBULE (RIGID INSULATION) CAVITY INSULATION
EQUIPPED WITH SELF-CLOSING DEVICES. VESTIBULES SHALL BE DESIGNED SO THAT IN PASSING THROUGH THE VESTIBULE IT IS NOT R-VALUE = 13
NECESSARY FOR THE INTERIOR AND EXTERIOR DOORS TO OPEN AT THE SAME TIME.
R-13 FIBERGLASS INSULATION
R-VALUE = 13
EXCEPTIONS:
8" CMU
1. DOORS NOT INTENDED TO BE USED BY THE PUBLIC, SUCH AS DOORS TO MECHANICAL OR ELECTRICAL EQUIPMENT ROOMS,
OR INTENDED SOLELY FOR EMPLOYEE USE.
PROJECT
2. DOORS OPENING DIRECTLY FROM A SLEEPING UNIT OR DWELLING UNIT.
3. DOORS THAT OPEN DIRECTLY FROM A SPACE LESS THAN 3,000 SQUARE FEET (298 SQUARE METERS) IN AREA.
4. REVOLVING DOORS (PROVIDED, HOWEVER, THAT THE INSTALLATION OF ONE OR MORE REVOLVING DOORS IN THE BUILDING
ENTRANCE SHALL NOT ELIMINATE THE REQUIREMENT THAT A VESTIBULE BE PROVIDED ON ANY DOORS ADJACENT TO REVOLVING DOORS). 1/2" PREMOLD FILLER
1668 EASTERN PARKWAY
5. DOORS USED PRIMARILY TO FACILITATE VEHICULAR MOVEMENT OR MATERIAL HANDLING AND ADJACENT PERSONNEL DOORS.
6" CONCRETE SLAB BROOKLYN, NEW YORK
C402.4.8 RECESSED LIGHTING
RECESSED LUMINAIRES INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED CAVITY INSULATION
AND UNCONDITIONED SPACES. ALL RECESSED LUMINAIRES SHALL BE IC-RATED AND LABELED AS HAVING AN AIR LEAKAGE RATE OF NOT (RIGID INSULATION)
MORE 2.0 CFM (0.944 L/S) WHEN TESTED IN ACCORDANCE WITH ASTM E 283 AT A 1.57 PSF (75 PA) PRESSURE DIFFERENTIAL. ALL
RECESSED LUMINAIRES SHALL BE SEALED WITH A GASKET OR CAULK BETWEEN THE HOUSING AND INTERIOR WALL OR CEILING COVERING.
R-VALUE = 13
3/4" POLYSTYRENE
ENERGY COMPLIANCE
1/2" PREMOLD FILLER
2 LAYERS OF 3/4" PLYWOOD
(XPS) RIGID FORM
R-3 INSULATION
WALL DETAILS
CONTINUOUS INSULATION
OPERATING & MAINTENANCE MANUAL NOTES R-VALUE = 3 SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
C408.2.5.2 MANUALS DRAWING BY: CC
AN OPERATING AND MAINTENANCE MANUAL IS TO BE PROVIDED TO THE BUILDING OWNER BY THE MECHANICAL CONTRACTOR AND
INCLUDE ALL OF THE FOLLOWING: CHK BY: M Kang
1. SUBMITTAL DATA STATING EQUIPMENT SIZE AND SELECTED OPTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE. DWG No:
2. MANUFACTURER'S OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING MAINTENANCE, EXCEPT
EQUIPMENT NOT FURNISHED AS PART OF THE PROJECT. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED.
3. NAMES AND ADDRESS OF AT LEAST ONE SERVICE AGENCY.
4. HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL
SEQUENCE DESCRIPTIONS. DESIRED OR FIELD-DETERMINED SETPOINTS SHALL BE PERMANENTLY RECORDED ON CONTROL DRAWINGS AT
EN-101.00
CONTROL DEVICES OR, FOR DIGITAL CONTROL SYSTEMS, IN SYSTEM PROGRAMMING INSTRUCTIONS.
5. A NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE, INCLUDING RECOMMENDED SETPOINTS.
PAGE: 25 OF 32
62'-5"
ROOF OF ELEVATOR MACHINE ROOM
ROOF OF ELEVATOR MACHINE ROOM +151'-2"
ROOF OF ELEVATOR MACHINE ROOM 20'-3 1/2" 39'-0"
+151'-2"
+151'-2"
WALL TYPE -1 WALL TYPE -2 12'-4"
(CMU + METAL PANEL) ROOF OF STAIR (CMU + STUCCO)
84'-4" BUILKHEAD
GROSS AREA = (62'-5" X 64'-2" ) GROSS AREA = (68'-0"+68'-8")X20'-3.5"/2
ROOF OF STAIR BUILKHEAD + (2.5'' X 10'-7")/2 - (7"X29'-8")/2
= 4,005.1 +2.2 - 8.7
ROOF OF STAIR BUILKHEAD
+142'-2" + (68'-8"+64'-4.5")X39'-0"/2+ 12'-4" X 9'-0"
=1386.6+ 2594.3 + 111
MICHAEL KANG
+142'-2"
ARCHITECT, PLLC.

9'-0"
= 3999 SF +142'-2" = 4,092 SF

Architectural, Interior Design, Zoning & Building Code Expertise


ROOF
37-01 Main Street, Suite #308, Flushing, NY 11354
ROOF +133'-2" michaelkangra@yahoo.com
ROOF
+133'-2"
+133'-2" Tel: (718) 353-2929
Fax: (718) 661-1619

6TH FLOOR
6TH FLOOR +123'-2"
6TH FLOOR
+123'-2"
+123'-2"

5TH FLOOR
5TH FLOOR +113'-2"
5TH FLOOR
+113'-2"
+113'-2"

4TH FLOOR

68'-8"

64'-4 1/2"
4TH FLOOR +103'-2"
4TH FLOOR

68'-0"
64'-2"

+103'-2"
+103'-2"

3RD FLOOR
3RD FLOOR +93'-2"
3RD FLOOR
+93'-2"
+93'-2"

8'-2"
9'-0" 2ND FLOOR
2ND FLOOR +83'-2"
HOTEL SIGNAGE 2'-6" 2ND FLOOR
+83'-2" 3'-6" 7'-0"
9'-7" 7'-0" +83'-2"
4'-2"

12'-7"
3'-0"
11'-10"

11'-10"

11'-10"
1688
12'-10"

3'-4" 6'-0" 3'-4" 1ST FLOOR


+73'-2"
8'-8"

7'-0"
8'-0"

1ST FLOOR
7'-0"

+73'-2" MEAN CURB LEVEL


1ST FLOOR +68'-5"

5'-8"

4'-10"

5'-4"
7"
+69'-0"
2 1/2"

9'-9 1/2"
5'-11"

6'-6"

2'-0"
10'-7" 29'-8"

9'-6"
CELLAR
10'-0"

CELLAR
9'-10"

+63'-2''

+63'-2" WALL TYPE -1


7'-0" WALL TYPE -3
(CMU + METAL PANEL) (CONCRETE WALL) 20'-3 1/2" 24'-0" 15'-0"
GROSS AREA = 84'-4" X 68' = 5,735 SF GROSS AREA = 84'-4" X 2' = 169 SF
10'-7" 23'-9" 28'-1"
WALL TYPE -3.2
WEST ELEVATION (CONCRETE WALL) WALL TYPE -3.1
WALL TYPE -3.1 WALL TYPE -3.2 GROSS AREA = (2'-0"+4'-10")X20'-3.5"/2 (CONCRETE WALL)
WINDOW W1A & W2 CURTAIN WALL WINDOW CW1-CW4
(CONCRETE WALL) (CONCRETE WALL)
EAST ELEVATION
+ (4'-10" + 5'-4")X24'-0"/2 GROSS AREA =(9'-6"+9'-9.5")X15'-0" / 2
CASEMENT WINDOW FIXED WINDOW GROSS AREA = (9'-10"+ 10'-0")X10'-7"/2 GROSS AREA = (5'-11"+ 6'-6")X28'-1"/2 WINDOW W1 & W3 = 69 + 122 WALL TYPE -3 TOTAL = 145 SF
LOW-E LOW-E + 10'-0" X 23'-9" = 174 SF CASEMENT WINDOW
U-FACTOR = 0.28 U-FACTOR = 0.28 = 105 + 238 = 191 SF (CONCRETE WALL)
LOW-E
SHGC = 0.28 SHGC = 0.33 = 343 SF WALL TYPE -3 TOTAL U-FACTOR = 0.28 GROSS AREA = 191 + 145
AIR INFILTRATION = 0.07 AIR INFILTRATION = 0.01 (CONCRETE WALL) SHGC = 0.28 = 336 SF
GROSS AREA = 343 + 174 = 517 SF AIR INFILTRATION = 0.07
WINDOW-W1A = (9'-0" x 8'-2"= 73.5 sf) x 10 = 735 SF
WINDOW-W2 = (9'-0" x 8'-2"= 73.5 sf) x 15 = 1,103 SF WINDOW-W1 = (7'-0" x 8'-2"= 57.17) x 42 = 2,401 SF
WINDOW-CW1 = 9'-0" x 11'-10" + 12'-7" X 4'-2" + 2(3'-4" X 8'-8") = 213 SF WINDOW-W3 = (7'-0" x 5'-8" = 39.67 SF) X 7 = 278 SF
WINDOW-CW2 = 3'-6" x 12'-10" + 2'-6" X 11'-10" = 75 SF
WINDOW-CW3 = 9'-7" x 11'-10" = 113 SF
WINDOW-CW4 = 7'-0" x 11'-10" = 83 SF

EXTERIOR DOOR - ED1= 6'-0" X 8'-0" = 48 SF


EXTERIOR DOOR - ED2= 3'-0" X 7'-0" = 21 SF
EXTERIOR DOOR - ED3 = 3'-0" x 7'-0" = 21 SF

ROOF OF ELEVATOR MACHINE ROOM


+151'-2"
52'-8"

12'-4"
ROOF OF STAIR BUILKHEAD
+142'-2"
9'-0"

WINDOW PERFORMANCE SCHEDULE: BUILDING ENVELOPE AREA AND FENESTRATION ANALYSIS REV.# DATE DESCRIPTION
ROOF
+133'-2" ORIENTATION COMPONENT GROSS AREA FENESTRATION (C402.3.1) KEY PLAN
TYPE DESCRIPTION R.O./M.O. GLASS TYPE U-FACTOR SHGC AIR LEAKAGE NOTES

W1 ALUM-FRAMED 7'-0" X 8'-2" LOW-E, CLEAR 0.28 0.28 < 0.07 CFM/SF 1, 3 WEST EXTERIOR WALL 3999 SF EXTERIOR SURFACE WALL ABOVE GRADE = 3,999 SF
CASEMENT WINDOW (WALL TYPE - 1/
CMU + METAL PANEL)
6TH FLOOR N
+123'-2" W1A ALUM-FRAMED 9'-0" X 8'-2" LOW-E, CLEAR 0.28 0.28 < 0.07 CFM/SF 1, 3
CASEMENT WINDOW WINDOW 735 SF VERTICAL FENESTRATION AREA =
WINDOW 1,103 SF 735+1103+213+75+113+83+48+21+21= 2,412 SF
W2 ALUM-FRAMED 9'-0" X 8'-2" LOW-E, CLEAR 0.28 0.28 < 0.07 CFM/SF 1, 3
CURTAIN WALL 213 SF
CASEMENT WINDOW
5TH FLOOR CURTAIN WALL 75 SF
+113'-2" W3 ALUM-FRAMED 7'-0" X 5'-8" LOW-E, CLEAR 0.28 0.33 < 0.01 CFM/SF 1, 3 CURTAIN WALL 113 SF
FIXED WINDOW
CURTAIN WALL 83 SF
9'-0" x 11'-10"
CW1 ALUM-FRAMED + 12'-7" X 4'-2" LOW-E, CLEAR 0.28 0.33 < 0.01 CFM/SF 1, 3 AUTOMATIC SLIDING DOOR 48 SF
FIXED WINDOW + 2(3'-4" X 8'-8")
4TH FLOOR ALUM-FRAMED SWING DOOR 21 SF
63'-7"

+103'-2" CW2 ALUM-FRAMED 3'-6" x 12'-10" LOW-E, CLEAR 0.28 0.33 < 0.01 CFM/SF 1, 3 HOLLOW METAL DOOR 21 SF WALL TYPE-3/CONCRETE WALL 343+ 174 = 517 SF
68'-1"

FIXED WINDOW + 2'-6" X 11'-10" BELOW GRADE

CW3 ALUM-FRAMED 9'-7" x 11'-10" LOW-E, CLEAR 0.28 0.33 < 0.01 CFM/SF 1, 3 EAST EXTERIOR WALL 5,735 SF EXTERIOR SURFACE WALL ABOVE GRADE = 5,735 SF PROJECT
FIXED WINDOW (WALL TYPE - 1/
3RD FLOOR CMU + METAL PANEL)
+93'-2" CW4 ALUM-FRAMED 7'-0" x 11'-10" LOW-E, CLEAR 0.28 0.33 < 0.01 CFM/SF 1, 3 1668 EASTERN PARKWAY
FIXED WINDOW WINDOW 2,401 SF VERTICAL FENESTRATION AREA =
WINDOW 278 SF
BROOKLYN, NEW YORK
2,401 + 278 = 2,679 SF

2ND FLOOR
DOOR PERFORMANCE SCHEDULE:
WALL TYPE-3/CONCRETE WALL 169 SF
+83'-2"
ED1 EXTERIOR DOOR
- AUTOMATIC SLIDING DOOR
(2) 3'-0" X 8'-0" LOW-E, CLEAR 0.64 0.29 < 0.07 CFM/SF 1, 2 BELOW GRADE
ENERGY COMPLIANCE
EXTERIOR SURFACE WALL ABOVE GRADE =4,092 SF

ED2 EXTERIOR DOOR 3'-0" X 7'-0" LOW-E, CLEAR 0.64 0.29 < 0.07 CFM/SF 1, 2
NORTH EXTERIOR WALL
(WALL TYPE - 1/
4,092 SF
ENVELOPE ANALYSIS
1ST FLOOR CMU + STUCCO)
- ALUM-FRAMED SWING DOOR
+73'-2" 191+145 = 336 SF
SEAL & SIGNATURE: DATE: 04-20-16
WALL TYPE-3/CONCRETE WALL
ED3 EXTERIOR DOOR 3'-0" X 7'-0" LOW-E, CLEAR 0.42 BELOW GRADE PROJECT No: 201601
MEAN CURB LEVEL
- INSULATED HOLLOW METAL DRAWING BY: CC
+68'-5"
6'-6"

SOUTH EXTERIOR WALL 3,568 SF EXTERIOR SURFACE WALL ABOVE GRADE = 3,568 SF
CHK BY: M Kang
2'-0"

CELLAR (WALL TYPE - 1/


CMU + STUCCO) DWG No:
+63'-2'' 52'-8" WALL TYPE-3/CONCRETE WALL 223 SF
BELOW GRADE
WALL TYPE -3 WALL TYPE -2
(CONCRETE WALL)
GROSS AREA = (6'-6"+2'-0")X52'-8"/2
(CMU + STUCCO)
GROSS AREA = (63'-7"+68'-1")X52'-8"/2
EN-102.00
= 223 SF + 12'-4" X 9'-0"
=3467.2 + 101 PAGE: 26 OF 32
= 3,568 SF
ELECTRICAL GENERAL NOTES NYCECC TALBE C405.5.2
INTERIOR LIGHTING POWER
1. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORKS. ROOM TYPE CONTROL STRATEGY
FOLLOW DRAWINGS IN LAYING OUT WORK AND CHECK DRAWINGS OF OTHER TRADES TO VERIFY LIGHTING CONTROL NARRATIVES IN AREA TYPE TENANT AREA OR PORTION AREA (FT 2 ) ALLOWED WATTAGE
SPACE CONDITIONS MAINTAIN HEADROOM AND SPACE CONDITIONS.
COMPLIANCE WITH 2014 NYCECC: AUTOMATIC ON/OFF OF 75% OF FIXTURES, 25% OF OF BUILDING (W/FT 2 ) MICHAEL KANG
2. SECURE ALL SUPPORTS TO BUILDING STRUCTURE UTILIZING TOGGLE BOLTS (HOLLOW MASONRY). FIXTURES TO REMAIN ENERGIZED AT ALL TIMES
EXPANSION SHIELDS OR INSERTS (CONCRETE AND BRICK), MACHINE SCREWS (METAL), BEAM C405.1
CORRIDOR/ ELEVATOR LOBBY
WITH EMERGENCY BATTERY PACK (I.E. EMERGENCY
DINING AREA 1.3 323 1.3 X 323 = 420
ARCHITECT, PLLC.
CLAMPS (FRAMEWORK), WOOD SCREWS (WOOD) OR PAN THRU STRAPS (METAL DECK). NAILS, AT LEAST 75% OF NEWLY INSTALLED PERMANENT LIGHTING FIXTURES USE FIXTURES TO REMAIN ON)
Architectural, Interior Design, Zoning & Building Code Expertise
RAWL PLUGS AND WOOD PLUGS ARE NOT PERMITTED. WHERE REQUIRED BY STRUCTURE, PROVIDE HIGH-EFFICACY LAMPS WITHIN DWELLING UNITS
H/C RESTROOM, (CELLAR FL.) HOTEL LOBBY 2.1 549 2.1 X 549 = 1,153 37-01 Main Street, Suite #308, Flushing, NY 11354
THRU BOLTS AND FISH PLATES. SUPPORT HORIZONTAL RUNS OF METALLIC RACEWAYS NOT MORE LOCAL SWITCHES WITH OCCUPANCY SENSOR michaelkangra@yahoo.com
THAN 10 FT APART. SUPPORT RACEWAY RISERS AT EACH FLOOR LEVEL. RUN EXPOSED RACEWAYS AUTOMATICALLY TURN OFF LIGHTS WITHIN 30
GUEST ROOMS 1.1 25813 1.1 X25813 = 28,394
PARALLEL WITH OR AT RIGHT ANGELS TO WALLS. MINUTES OF ALL OCCUPANTS LEAVING THE SPACE Tel: (718) 353-2929
Fax: (718) 661-1619
3. PASS RACEWAYS OVER WATER, STEAM OR OTHER PIPING WHEN PULL BOXES ARE NOT REQUIRED. STAIRS ASTRONOMICAL TIMECLOCK WITH OCCUPANCY
NO RACEWAY WITHIN 3 INCHES OF STEAM OR HOT WATER PIPES OR APPLIANCES (EXCEPT PIPE
CROSSINGS WHERE RACEWAY SHALL BE AT LEAST 1 INCH FROM PIPE COVERS)
C405.2.1.1 SENSOR TO DE-ENERGIZE 50% OF FIXTURES. 50% OF
FIXTURES REMAIN ENERGIZED AT ALL TIMES WITH
INTERIOR LIGHTING SCHEDULE
EACH AREA ENCLOSED BY WALLS OR FLOOR-TO CEILING PARTITIONS
SHALL HAVE AT LEAST ONE MANUAL CONTROL FOR THE LIGHTING EMERGENCY BATTERY PACK
4. CUT CONDUIT ENDS SQUARE. REAM SMOOTH. PAINT MALE THREAD OR FIELD THREADED RACEWAYS DINING AREA
WITH GRAPHITE BASE PIPE COMPOUNT. DRAW UP TIGHT WITH RACEWAY COUPLING. SERVING THAT AREA. THE REQUIRED CONTROLS SHALL BE LOCATED
MECHANICAL, METER, BICYCLE STORAGE,
WITHIN THE AREA SERVED BY THE CONTROLS TO BE A REMOTE SWITCH
COMPACTOR & ELEVATOR MACHINE ROOM SYMBOL MANUFACTURER LAMP WATAGES QUANTITY TOTAL WATTAGES
5. HORIZONTAL OR CROSS RUNS IN PARTITIONS AND WALLS ARE NOT PERMITTED. DO NOT RUN THAT IDENTIFIES THE LIGHTS SERVED AND INDICATES THEIR STATUS. LOCAL SWITCHES WITH OCCUPANCY SENSOR
CONDUIT IN PRECAST ROOF SLABS, IN 2 INCH SLABS OR IN TERRAZZO FLOOR FINISH. EXCEPTIONS: AUTOMATICALLY TURN OFF LIGHTS WITHIN 30
MINUTES OF ALL OCCUPANTS LEAVING THE SPACE R16 CEILING MOUNT HALOGEN 23 11 23 X11 = 253
1. AREAS DESIGNATED AS SECURITY OR EMERGENCY AREAS LIGHTING FIXTURE < 420 ... OK
6. LEAVE WIRES WITH SUFFICIENT SLACK TO PERMIT MAKING FINAL CONNECTIONS. RACEWAYS OVER THAT NEED TO BE CONTINUOUSLY LIGHTED.
10 FT LONG IN WHICH WIRING IS NOT INSTALLED: FURNISH FISH WIRE. C405.2.1.2 HOTEL GUESTROOMS
LIGHT REDUCTION COONTROLS MASTER SWITCH BY ENTRY OF EACH ROOM THAT
SET BOXES SQUARE AND TRUE WITH BUILDING FINISH. ERECT WALL AND SWITCH OUTLETS IN (CELLAR - 3RD FL.)
7. EACH AREA THAT IS REQ'D TO HAVE A MANUAL CONTROL SHALL ALSO CONTROLS ALL PERMANENTLY WIRED LUMINARIES HOTEL LOBBY
ADVANCE OF FURRING AND FIREPROOFING. SECURE TO BUILDING STRUCTURE BY ADJUSTABLE ALLOW THE OCCUPANT TO REDUCE THE CONNECTED LIGHTING LOAD RESIDENTIAL APARTMENT AND SWITCHED RECEPTACLES
STRAP IRONS. IN A REASONABLY UNIFORM ILLUMINATION PATTERN BY AT LEAST 50% (4TH - 6TH FL.) SYMBOL MANUFACTURER LAMP WATAGES QUANTITY TOTAL WATTAGES
8. VERIFY LOCATIONS OF OUTLETS AND SWITCHES IN FINISHED ROOMS WITH ARCHITECTURAL LIGHTING REDUCTION SHALL BE ACHIEVED BY ONE OF THE FOLLOWING OR
OTHER APPROVED METHOD: EXTERIOR PARKING LOT, OUTDOOR CANOPY CEILING MOUNT HALOGEN 23 32 23 X 32 = 736
DRAWINGS OF INTERIOR DETAILS AND FINISH. IN CENTERING OUTLETS AND LOCATING BOXES AND LOCAL SWITCH WITH OUTDOOR DAYLIGHT SENSOR R16
1. CONTROLLING ALL LAMPS OR LUMINAIRES; THAT AUTOMATICALLY TURNS OFF THE LIGHTING LIGHTING FIXTURE < 1153 ... OK
OUTLETS, ALLOW FOR OVERHEAD PIPES, DUCTS AND MECHANICAL EQUIPMENT, VARIATIONS IN
FIREPROOFING AND PLASTERING, WINDOW AND DOOR TRIM, PANELING, HUNG CEILINGS AND THE 2. DUAL SWITCHING OF ALTERNATE ROWS OF LUMINAIRES, ALTERNATE WHEN DAYLIGHT IS AVAILABLE
LUMINAIRES OR ALTERNATE LAMPS;
LIKE, CORRECT ANY INACCURACY RESULTING FROM FAILURE TO DO SO WITHOUT EXPENSE TO
3. SWITCHING THE MIDDLE LAMP LUMINAIRES INDEPENDENTLY OF THE ROOF TERRACE LOCAL SWITCH WITH DAYLIGHT SENSORS
OUTER LAMPS; OR
GUEST ROOMS
9. LOCATIONS INDICATED FOR LOCAL WALL SWITCHES ARE SUBJECT TO MODIFICATIONS AT OR NEAR
NEAR DOORS. COORDINATE WITH ARCHITECT AND INSTALL SWITCH ON SIDE OPPOSITE HINGE. 4. SWITCHING EACH LUMINAIRE OR EACH LAMP. ENTRANCE LOBBY MASTER SWITCH BEHIND RECEPTION DESK/ SYMBOL MANUFACTURER LAMP QUANTITY TOTAL WATTAGES
VERIFY FINAL HINGE LOCATIONS IN FIELD PRIOR TO SWITCH OUTLET INSTALLATION. EXCEPTION: LIGHT REDUCTION CONTROLS NEED NOT BE PROVIDED IN THE BREAKFAST AREA BREAKFAST AREA THAT CONTROLS ALL WATTAGES
FOLLOWING AREAS AND SPACES: PERMANENTLY WIRED LUMINARIES AND SWITCHED
10. COVERS OF JUNCTION AND PULLBOXES SHALL BE READILY ACCESSIBLE. RECEPTACLES
1. AREAS THAT HAVE ONLY ONE LUMINAIRE, WITH RATED POWER LESS CEILING MOUNT 23 214 23 X 214 = 4,922
11. PROVIDE PULLBOXES WHERE INDICATED, WHERE REQUIRED BY CODE AND WHEREVER NECESSARY THAN 100 WATTS. C405.2.2. 3 DAYLIGHT ZONE CONTROL R16

TO FACILITATE PULLING OF WIRE. COORDINATE PULLBOX LOCATIONS WITH OTHER TRADES. HALOGEN LIGHTING
2. AREAS THAT ARE CONTROLLED BY AN OCCUPANT-SENSING DEVICE. DAYLIGHT ZONES SHALL BE DESIGNED SUCH THAT LIGHTS IN THE DAYLIGHT ZONE ARE CONTROLLED INDEPENDENTLY OF
FIXTURE
3. CORRIDORS, EQUIPMENT ROOMS, STOREROOMS, RESTROOMS, PUBLIC GENERAL AREA LIGHTING AND ARE CONTROLLED IN ACCORDANCE WITH EITHER SECTION C405.2.2.3.1 OR SECTION
12. EMPTY RACEWAYS RUNS: PROVIDE PULLBOXES EVERY 100 FT AND AS INDICATED. COORDINATE C405.2.2.3.2.. EACH DAYLIGHT CONTROL ZONE SHALL NOT EXCEED 2500 SF. CONTIGUOUS DAYLIGHT ZONES ADJACENT TO D168
LOCATIONS WITH OTHER TRADES.
LOBBIES, ELECTRICAL OR MECHANICAL ROOMS. W WATERPROOF LED 15 68 15 X 68 = 1,020
4. SLEEPING UNIT. VERTICAL FENESTRATION ARE ALLOWED TO BE CONTROLLED BY A SINGLE CONTROLLING DEVICE PROVIDED THAT THEY LIGHT FIXTURE
13. JUNCTION AND PULLBOXES: LOCATE GENERALLY NOT EXPOSES IN FINISHED SPACES. WHERE DO NOT INCLUDE ZONES FACING MORE THAN TWO ADJACENT CARDINAL ORIENTATIONS. DAYLIGHT ZONES UNDER
5. SPACES THAT USE LESS THAN 0.6 WATTS PER SQUARE FOOT (6.5 W/m ) RECESSED
NECESSARY, REROUTE RACEWAYS OR MAKE OTHER ARRANGEMENTS FOR CONCEALMENT. SKYLIGHTS MORE THAN 15 FEET FROM THE PERIMETER SHALL BE CONTROLLED SEPARATELY FROM DAYLIGHT ZONES
6. DAYLIGHT SPACES COMPLYING WITH SECTION C405.2.2.3.2. ADJACENT TO VERTICAL FENESTRATION. 26 73 26 X 73 = 1,898
D162 WALL SCONCE -
14. SUPPORT PANEL, JUNCTION AND PULLBOXES INDEPENDENTLY TO BUILDING STRUCTURE WITH NO C405.2.2.2 COMPACT FLUORESCENT
WEIGHT BEARING ON RACEWAYS. OCCUPANCY SENSORS SHALL BE INSTALLED IN MECHANICAL ROOMS, C405.2.4
2 LIGHTING FIXTURE
WATER METER ROOM , GAS METER ROOM, ELECT. METER ROOM, BICYCLE EXTERIOR LIGHTING AT PARKING LOT SHALL BE PROVIDED WITH A
15. ALL ACCESS DOOR LOCATIONS SHALL BE REVIEWED BY ARCHITECT PRIOR TO INSTALLATION. STORAGE ROOM, LAUNDRY, COMPACTOR ROOMS & ELEVATOR MOTOR CONTROL THAT AUTOMATICALLY TURNS OFF THE LIGHTING WHEN F07 LINEAR FLUORESCENT 30 25 30 X 25 = 750
ROOM. DAYLIGHT IS AVAILABLE LIGHTING FIXTURE
16. PROVIDE CABLE SUPPORTS FOR WIRE IN RISER CONDUITS AS REQUIRED PULL ON THERMOPLASTIC
C405.4 (MANDATORY)
WIRES AT TEMPERATURES LOWER THAN 32F (OC). BY CODE.
INTERNALLY ILLUMINATED EXIT SIGNS SHALL NOT EXCEED 5 WATTS PER
SIDE. F06 EM LINEAR FLUORESCENT 30 60 30 X 80 = 1,800
17. PROVIDE SEPARATE RACEWAYS FOR CONDUCTORS OF NORMAL AND EMERGENCY CIRCUITS.
COMMON BOXES: PROVIDE BARRIERS BETWEEN EMERGENCY AND NORMAL WIRING. LIGHTING FIXTURE

18. HEIGHTS OR OUTLETS FROM FINISHED FLOOR TO CENTERLINE OF OUTLET:


EXIT LIGHT 5 - -
RECEPTACLES AND TELEPHONE:
GENERALLY 1'-6" TOTAL 10, 390
OVER WORK BENCHES 3'-6" < 28,394 SF
WALL SWITCHES 4'-0"
WALL FIXTURES 7'-0"
MOTOR CONTROLLERS 5'-0" LIGHT FIXTURE SCHEDULE
GONGS AND HORNS 7'-0"
FIRE ALARM STATIONS 4'-0"
STROBE LIGHTS
(WHICHEVER IS LOWER) SYMBOL DESCRIPTION MANUFACTURER NYCECC TALBE C405.6.2
6'-8" AFF OR 6" BELOW CEILING EXTERIOR LIGHTING POWER
EXCEPTION: AT JUNCTION OF DIFFERENT WALL FINISH MATERIALS, ON KICHLER LIGHTING 10687 FREEPORT 2 LIGHT WALL SCONCE
MOLDING OR BREAK IN WALL SURFACE, IN VIOLATION OF CODE D162 D162
REQUIREMENTS, AS NOTED OR DIRECTED. (13X2 = 26 WATTS) AREA TYPE TENANT AREA OR PORTION AREA (FT 2 ) ALLOWED WATTAGE
19. WIRE COLOR CODING: AS PER CODE. WHERE COLOR-CODED CABLE IS NOT AVAILABLE, CERTIFY OF BUILDING (W/FT 2 )
IN WRITING AND REQUEST PERMISSION FOR OVERLAP COLOR TAPING OF CONDUCTORS (MINIMUM
LENGTH 6") IN ACCESSIBLE LOCATIONS. COLOR CODING, ONCE SELECTED, MUST BE USED F07 F07 METALAX 48 IN. FLUORESCENT WRAP LIGHT (30 WATTS) ENTRY CANOPY 0.25 111 0.25 X111 =28
CONSISTENTLY FOR THE ENTIRE PROJECT.
20. INSTALL NEW WORK AND CONNECT TO EXISTING WORK WITH MINIMUM INTERFERENCE TO EXISTING OPEN SPACE 0.14 7392 0.14 X 7392 = 1,035
FACILITIES. TEMPORARY SHUTDOWNS: ONLY EXISTING FACILITIES. ALARM AND EMERGENCY SYSTEMS
ARE NOT TO BE WITH WRITTEN CONSENT OF OWNER. MAINTAIN CONTINUOUS OPERATION OF EM F06 F06 METALAX 36 IN. FLUORESCENT WRAP LIGHT (30 WATTS) ROOF 0.14 3138 0.14 X 3138 = 439
INTERRUPTED.
REV.# DATE DESCRIPTION
21. FIRESTOPPING SHALL BE INSTALLED WHENEVER WIRING OR RACEWAYS CROSS FIRE RATED
CONSTRUCTION KEY PLAN
R16 R16 LIGHTOLIER 5" RECESSED LIGHT (23 WATTS) EXTERIOR LIGHTING SCHEDULE

ENTRY CANOPY N
D168 D168 INFOR - IP65 - (15 WATTS)
W WATERPROOF LED LIGHT FOR BATHROOM SYMBOL MANUFACTURER LAMP WATAGES QUANTITY TOTAL WATTAGES
AUTOMATIC CONTROL DEVICES SHALL BE INSTALLED IN THE FOLLOWING SPACES TO AUTOMATICALLY TURN OFF
LIGHT BOX - 6" LED 6.5 4 6.5 X4 = 26
LIGHTS WITHIN 30 MINS. OF ALL OCCUPANTS LEAVING THE SPACE AS FOLLOW: D180
DOWNLIGHT MODULE < 28 ... OK

1. OCCUPANCY SENSORS SHALL BE INSTALLED IN ALL CLASSROOMS, MEETING ROOMS, EMPLOYEE BREAKROOMS,
D180 D180 LITEBOX - 6" LED DOWNLIGHT MODULE (6.5 WATTS INPUT POWER)
AND OFFICES SMALLER THAN 200 SF. THESE SHALL BE MANUAL-ON SWITCHES. SUCH SENSORS AND CONTROLS OPEN SPACE
SHALL NOT HAVE AN OVERRIDE SWITCH THAT CONVERTS FROM MANUAL-ON TO AUTOMATIC-ON FUNCTIONALITY.
THE OCCUPANCY SENSOR MAY HAVE A GRACE PERIOD OF UP TO 30 SECONDS TO TURN ON THE LIGHTING SYMBOL MANUFACTURER LAMP WATAGES QUANTITY TOTAL WATTAGES
AUTOMATICALLY AFTER THE SENSOR HAS TURNED OFF THE LIGHTING IF OCCUPANCY IS DETECTED. WALL SCONE - LED LIGHT 25 12 25 X12 = 300
P188
P188 WALL SCONE - LED LIGHT (13 WATTS INPUT POWER) < 1,035 ... OK
2. OCCUPANCY SENSORS SHALL BE INSTALLED IN RESTROOMS, STORAGE ROOMS, PRIVATE OFFICE 200 SF OR P188 PROJECT
GREATER, JANITOR CLOSETS, AND OTHER SPACES 300 SF IN AREA OR LESS ENCLOSED BY FLOOR-TO-CEILING HT.
PARTITIONS, EXCEPT FOR SPACES LISTED IN ITEM 1. THESE AUTOMATIC CONTROL DEVICES SHALL EITHER BE
MANUAL-ON OR SHALL BE CONTROLLED TO AUTOMATICALLY TURN THE LIGHTING ON TO NOT MORE THAN 50 EXIT LIGHT
ROOF
1668 EASTERN PARKWAY
SYMBOL MANUFACTURER LAMP WATAGES QUANTITY TOTAL WATTAGES BROOKLYN, NEW YORK
PERCENT POWER.
WALL SCONE - LED LIGHT 25 4 25 X4 = 100
P188 < 439 ... OK
LIGHT SWITCHES WITH DIMMER CONTROL
DAYLIGHT ZONES SHALL BE DESIGNED SUCH THAT LIGHTS IN THE DAYLIGHT ZONE ARE CONTROLLED LIGHTING NOTES
INDEPENDENTLY OF GENERAL AREA LIGHTING AND ARE CONTROLLED IN ACCORDANCE WITH EITHER SECTION
C405.2.2.3.1 OR SECTION C405.2.2.3.2.. EACH DAYLIGHT CONTROL ZONE SHALL NOT EXCEED 2500 SF. CONTIGUOUS
M MASTER SWITCHES FOR THE GUESTROOMS EXTERIOR LIGHTING CALCULATION
DAYLIGHT ZONES ADJACENT TO VERTICAL FENESTRATION ARE ALLOWED TO BE CONTROLLED BY A SINGLE SEAL & SIGNATURE: DATE: 04-20-16
ALLOWABLE WATTAGES:
CONTROLLING DEVICE PROVIDED THAT THEY DO NOT INCLUDE ZONES FACING MORE THAN TWO ADJACENT 28 + 1,035 +439 = 1,502 W PROJECT No: 201601
CARDINAL ORIENTATIONS. DAYLIGHT ZONES UNDER SKYLIGHTS MORE THAN 15 FEET FROM THE PERIMETER SHALL DRAWING BY: CC
BE CONTROLLED SEPARATELY FROM DAYLIGHT ZONES ADJACENT TO VERTICAL FENESTRATION. DL DAYLIGHT SENSOR CONTROL PROPOSED WATTAGES: CHK BY: M Kang
26 + 300 + 100 = 426 W < 1,502 W ... OK
DWG No:

OS OCCUPANCY SENSOR CONTROL


INTERNALLY ILLUMINATED EXIT SIGNS SHALL NOT EXCEED 5 WATTS PER SIDE. EN-201.00
PAGE: 27 OF 32
CELLAR - BREAKFAST AREA CELLAR - GUEST ROOMS & OTHER AREAS

MICHAEL KANG
LIGHT TYPE QUANTITY LIGHT TYPE QUANTITY ARCHITECT, PLLC.
Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com
EM F06
R16 11 3 Tel: (718) 353-2929
Fax: (718) 661-1619

F07 8

BREAKFAST AREA = 323 SF


R16 25

W
D168 8

D162 8
R16 R16 R16 R16 R16

GAS BICYCLE F07

METER PARKING
PANTRYR16 WATER
R16 ELEC.
METER RM.

F07

F07
R16 R16 R16
METER
OS

F07
F07
OS OS

OS
BREAKFAST

OS
R16 R16

OS
R16 AREA
R16 R16
F07
(16 SEATS)

EM
ELEV #1 ELEV #2
R16
D168 (STRETCHER STAIR 1

OS
(2500 LBS)
W ADAPTABLE) F07
COMPACTOR

F06
STAIR 2 GFI

F06 EM UP

F07
R16 S2 S1
D162

DN
EM

R16 R16 R16 R16 R16 R16 R16 R16 R16 R16 R16 R16

UP
F06

M D162 GFI GFI D162 M M D162 GFI GFI D162 M M GFI D162
S1 S1 S1 S1 S1 S1 S1 S1 S1
S2 S2 S2 S2 S2 S2 S2 S2 S2 S2

D168 D168 D168 D168


D168 W W W W D168
GFI D162 W W
R16 R16 R16 R16 R16
S1 GFI
D168 S2
W R16
M S2 S1 D162 REV.# DATE DESCRIPTION
S1
S2 KEY PLAN

R16 N
S1
S2
M
007 006 005 004 003 002 001
KING RM KING RM KING RM KING RM KING RM KING RM KING RM

PROJECT

1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

N
CELLAR
LIGHTING PLAN
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

EN-202.00
PAGE: 28 OF 32
1ST FLOOR - ENTRANCE LOBBY 1ST FLOOR - GUEST ROOMS & OTHER AREAS

MICHAEL KANG
ARCHITECT, PLLC.
LIGHT TYPE QUANTITY LIGHT TYPE QUANTITY Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619
R16 EM F06
20 9

F07 1
1ST FLOOR - OPEN SPACE

LIGHT TYPE QUANTITY R16 27


OPEN SPACE AREA = 7392 SF

12 W
D168 9
P188

VIA DAYLIGHT CONTROL CANOPY AREA = 111 SF VIA DAYLIGHT CONTROL


1ST FLOOR - CANOPY D162 9
W CP
DL

LOBBY AREA = 549 SF


D180 D180 D180 D180

LIGHT TYPE QUANTITY


P188 P188 P188 P188 P188
EM

R16 R16 R16 R16 R16 R16 R16 D180 4


RECEPTION
F06

P1
8
108 109

8
SWITCHES OF CANOPY LIGHTS
LOBBY
D/D RM KING RM R16 R16 R16 R16 R16 R16 R16
SWITCHES OF EXTERIOR
WALL MOUNT LIGHTS
DL OS CL R16
SWITCHES OF CORRIDOR LIGHTS
CP W 6 5 4 3 2 1 0 CELLAR TO 6TH FLOOR
EM

DL
UP R16 R16 R16 R16 R16 R16

F06 EM
D168
W

F0
F06

6
EM
S2 DN
S1
D162 GFI ELEV #1 ELEV #2
R16
R16 R16 (2500 LBS) (STRETCHER R16
STAIR 2 ADAPTABLE)

EM
S1 GFI D162 S1
DN
S2 S1 S2 STAIR 1

F06
M S2 M RPZ OFFICE
W
UP
EM

EM

D168

P1
R16 F06 EM

88
F07

R16

DN
F06

F06

R16 R16 R16 R16 R16 R16 R16 R16 R16 R16 R16 R16
UP

REV.# DATE DESCRIPTION


F06 DN EM M D162 GFI GFI D162 M M D162 GFI GFI D162 M M GFI D162
S1 S1 S1 S1 S1 S1 S1 S1 S1
S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 KEY PLAN
D168 D168 D168 D168
D168 D168
W W W W
GFI D162 R16 W W
R16 R16 R16 R16 R16
S1 GFI
D168 S2 N
W R16

M S2 S1 D162
S1
S2

P188
R16
S1
S2
M
107 106 105 104 103 102 101
KING RM KING RM KING RM KING RM KING RM KING RM KING RM

PROJECT
N

1668 EASTERN PARKWAY


P188 P188 P188 P188
BROOKLYN, NEW YORK

1ST FLOOR
LIGHTING PLAN
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
PROPOSED 11 VOLUNTARY PARKING SPACES DRAWING BY: CC
CHK BY: M Kang
DWG No:

EN-203.00
PAGE: 29 OF 32
2ND FLOOR - GUEST ROOMS & OTHER AREAS

MICHAEL KANG
ARCHITECT, PLLC.
LIGHT TYPE QUANTITY Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619
EM F06
8

F07 0

R16 27

W
D168 12
208 208 210 211 212
D/D RM KING RM D/D RM D/D RM KING RM

D162 12
R16

S2 S2
S1 S1
M M S2 S1
F06 EM
D168 D168
W W

F0
R16 R16

6
S2

EM
S2
S1 S1
GFI D162 D162 GFI ELEV #1 ELEV #2 GFI D162
(STRETCHER DN
(2500 LBS) R16
S2 ADAPTABLE) S2 S2

EM
GFI D162 D162 GFI
S1 S1 S1
STAIR 2 R16 S1 M R16 R16 M S1 M STAIR 1

F06
S2 S2
F06 EM
W W
D168 D168 UP
F06 EM
EM

EM

R16 R16 R16 R16 R16 R16 R16 R16 R16 R16 R16 R16
F06

F06

UP

F06 DN EM M D162 GFI GFI D162 M M D162 GFI GFI D162 M M GFI D162
S1 S1 S1 S1 S1 S1 S1 S1 S1
S2 S2 S2 S2 S2 S2 S2 S2 S2 S2

D168 D168 D168 D168


GFI D162 D168 D168
W W W W
R16 W W
S1 R16 R16 R16 R16 R16
D168 S2 GFI
W
R16
M S2 S1 D162
S1
S2

REV.# DATE DESCRIPTION

R16 KEY PLAN


S1
S2
M
207 206 205 204 203 202 201 N
KING RM KING RM KING RM KING RM KING RM KING RM KING RM

PROJECT

1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

2ND FLOOR
LIGHTING PLAN
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

EN-204.00
PAGE: 30 OF 32
3RD-6TH FLOOR - GUEST ROOMS & OTHER AREAS

MICHAEL KANG
ARCHITECT, PLLC.
LIGHT TYPE QUANTITY Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619
EM F06
8

F07 3

R16 26

F07

W
D168 11

X08 X09 X10 X11


MECH.
KING RM KING RM D/D RM D/D RM D162 11
F07

R16

S2 S2
S1 S1
M M S2 S1
F06 EM
D168 F07
W

F0
R16 R16

6
S2

EM
S1
GFI D162 D162 GFI ELEV #1 ELEV #2
(STRETCHER DN
(2500 LBS)
S2 ADAPTABLE) S2

EM
GFI D162 D162 GFI
S1 S1
STAIR 2 R16 S1 M R16 R16 M S1 STAIR 1

F06
OS
S2 S2
F06 EM
W W
D168 D168 UP
F06 EM
EM

EM

R16 R16 R16 R16 R16 R16 R16 R16 R16 R16 R16 R16
F06

F06

UP

F06 DN EM M D162 GFI


M M D162 GFI GFI D162 M M GFI D162
S1 S1 S1 S1 S1 S1 S1
S2 S2 S2 S2 S2 S2 S2 S2

D168
D168 D168 D168
GFI D162 D168 W D168
W W W
R16 W R16 R16 W
S1 GFI R16 R16
R16
D168 S2 GFI
W
R16 S2 S1 D162 S1 S2
M S2 S1 D162
REV.# DATE DESCRIPTION
S1
S2
KEY PLAN

R16 N
S1
S2
M
X07 X06 X05 X04 X03 X02 X01
KING RM KING RM D/D RM ADA RM KING RM KING RM KING RM

PROJECT

1668 EASTERN PARKWAY


BROOKLYN, NEW YORK

3RD-6TH FLOOR
LIGHTING PLAN
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
N CHK BY: M Kang
DWG No:

EN-205.00
PAGE: 31 OF 32
ROOF - INTERIOR ROOF- EXTERIOR

MICHAEL KANG
ARCHITECT, PLLC.
LIGHT TYPE QUANTITY LIGHT TYPE QUANTITY Architectural, Interior Design, Zoning & Building Code Expertise
37-01 Main Street, Suite #308, Flushing, NY 11354
michaelkangra@yahoo.com

Tel: (718) 353-2929


Fax: (718) 661-1619
EM F06
8 4
P188

F07 4
STAIR BULKHEAD
F07

ELEVATOR
MACHINE ROOM R16 0
STAIR BULKHEAD

F07

W
D168 0
OS

DN

D162 0

ROOF AREA = 3138 SF

REV.# DATE DESCRIPTION


F06 EM

KEY PLAN

F0
6
EM

DN
N

EM
F06

F06 EM

F06 EM
EM

EM

P188

P188
F06

F06

MECH. ROOM
F06 DN EM
F07

F07

P188
OS

PROJECT
P188
UP
1668 EASTERN PARKWAY
BROOKLYN, NEW YORK

ROOF
LIGHTING PLAN
SEAL & SIGNATURE: DATE: 04-20-16
PROJECT No: 201601
DRAWING BY: CC
CHK BY: M Kang
DWG No:

EN-206.00
N
PAGE: 32 OF 32