ENFORCING —
‘SAW CUT WITHIN 1 HRS OF SET
se
CONCRETE SLAB
ALANT, REFER NOTE 1
UT OUT EVERY SECONO WiRE
SLAB THICKNESS. no
CONTROL JOINT DETAIL (CJ)
[Ba MAX. SPACING
eweorcing —
50
TYP.
pe
DEPRESS REMFORCNG
/AINTAIN COVER
——10 wie
ALANT, REFER NO}
Sot
oo
FIRST POUR
SLAB THICKNESS
ENSURE DOWELS ARE STRAIGHT,
PERPENDICULAR TO JONT AND CAPPED
(USE OF PROPRIETARY SLEEVE MAY
BE REQURED)
= DONOT DISPLACE OURNG POUR
DOWELLED EXPANSION JOINT DE’
(1am MAX. SPACING!
‘SECOND POUR,
L_ crexseo power wire
EXPANSION CAP
INSTALL GRADE 316 S/S Dowels,
00mm LONG AT 600me CENT!
DDOWELS #12 N SLAB THICKNESS 100 AND LESS
316 IN SLAB THICKNESS 125 AND ABOVE
CLOSED CELL CROSS LINKED
POLYETHYLENE FOAM
{85-!504g/n9 OR EQUIVALENT
TAIL (DEu)
SEAL REFER NOTE 1
/
/ ve peerH mw
Sopp) wh ort ti
‘SAW CUT, OR BOLSTERED
‘AND DEEP To0.z0,
CONTROL JOINT
UNREINFORCED CONCRETE (CJU)
{FOR 1200 WOE FOOTPATHS)
CLOSED CELL CROSS LINKED
POLYETHYLENE Foam 0 woe
(a5-150eg/m) OR EQUIVALENT
SEALANT, REFER NOTE1
7 FRET POUR
2 OIA GRADE 316 SS
ROUND BAR £00 LONG @ 300 ‘~ GREASED ROO Wire
EXPANSION CAP
REFER DOWEL NOTE
DOWELLED EXPANSION JOINT
UNREINFORCED CONCRETE (DEJU}
{FOR 1200 WIDE FOOTPATHS)
NOTES
1. EXPANSION JONTS AND CONTROL JONTS ARE TO BE SEALED WITH
‘LOW MODULUS SELF PRIMING SEALANT TO THE MARUFACTURERS
SPECIFICATION. THE COLOUR OF THE SEALANT IS TO MATCH THE
‘ADJONNNG SURFACE FINSH
2. JONNT SPACING FOR 1200 WIDE FOOTPATHS ARE TO BE PROVIDED AS SHOWN
(ow ccc StD Owe 05-02-20
3. ALL CONSTRUCTION TO COMPLY WITH THE REQUIREMENTS OF AS 360,
Concave coDe
| DIMENSIONS ARE IN MILLIMETRES UNLESS SHOWN OTHERWISE
old Coast Cy Counc
STANDARD DRAWING
TECHNICAL SERVICES BRANCH
pas
05-02-205
CONCRETE JOINTS a
2005 EDITION