Blowing block
Technical features
Medium: Flow (Kv): Pilot valves: Materials
Compressed air (purity class P1: 1,3 m3/h 3/2 NO (P1, P2), Body: anodised aluminium
3.4.3 acc. to ISO 8573-1:2010) P2: 3,0 m3/h 3/2 NC (EXH) sol/spring valve Valve piston & seal:
5 m filtered, non-lubricated Exhaust: 5,1 m3/h Fluid/Ambient temperature: FDA compliant synthetic material
Operation: Port sizes (when fitted on base Fluid: O-rings: NBR
Poppet valve, solenoid pilot plate): +3 ... +30C max. Screws: steel, zinc coated
actuated Pre-blowing (P1) G3/4 Ambient: Flow control indicator:
Operating pressure: Blowing (P2) G1 0 ... +50C max. tempered stainless spring steel
Pre-blowing (P1) 5 12 bar Exhaust (EXH) G1 1/4
Blowing (P2) 6 40 bar Pilot air supply (PAS) G1/4
Pilot air supply (PAS) 6 10 bar Cavity (CAV) G1
P2 (bar) 36 38 40
PAS (bar) 7,2 7,6 8,0
Accessories
Connector Base plate Base plate to connect with Air recover valve Silencer
air recover valve
2/14 2013-5328b Our policy is one of continued research and development. We therefore reserve the right to amend, N/fb/en 5.25.100.01
without notice, the specifications given in this document. 2014 Norgren Switzerland
SPCH/100034
Pneumatic diagram SPCH/100034 with air recovery system and a possible pressure curve to
blow a PET bottle
Output to cavity Possibility for
pressure sensor
SPCH/100034 SPCH/100044
Check valve P1
Flow control P1 Pilot valve P1 NO Pilot valve P2 NO Pilot valve EXH NC Pilot valve AR NO
AR
P1 P2
Attention:
Pressurising procedure must be achieved as follow:
1) Pressurise PAS
2) After pressurising PAS the P2 / P1 is also to feed in the bloc delayed for minimum 1 second.
Recuperation range
Pressure
15 bar
at minimum 15 bar.
Otherwise EXH will not open completely.
0 Time
N/fb/en 5.25.100.02 Our policy is one of continued research and development. We therefore reserve the right to amend, 2013-5328b 2/14
without notice, the specifications given in this document. 2014 Norgren Switzerland
SPCH/100034
Dimensions 15,5
< 22
23
9
CAV
44
P2
18,5
32
< 22
P1
104
< 14
78
30
PAS
2,5
4 9,5
<4
52
12,5 44,5
25
1
5
NC
4
38
30
2
6
44
NO
3 10 9 8
7
93,5
7
6
32
5
4
2 3
2
1
30
NO
52 15,5 46,5
7,5
M8
10
68 56
8
1 Pilot valve NC
2 Pilot valve NO
3 Air control (P1)
40
CAV
8,5
G1
55
P2
182
196
182
131,5
G1
46
P1
G 3/4
PAS
15
G1/4
23
23,5
7
50 8,5 52
68 46
2/14 2013-5328b Our policy is one of continued research and development. We therefore reserve the right to amend, N/fb/en 5.25.100.03
without notice, the specifications given in this document. 2014 Norgren Switzerland
SPCH/100034
8,5
M8
CAV
G1
55
P2
220
182
151
157
131,5
G1
46
P1
G 3/4
PAS
15
G1/4
23
23,5
15
7
50 8,5 52
68 42
58
6
M6
40
34
37
14
37
40,5 9
G1/8
9
PAS
AR
79
143,5
29
10
45
34 33,9
58 24 9 Connector interface
82
68
N/fb/en 5.25.100.04 Our policy is one of continued research and development. We therefore reserve the right to amend,
2013-5328b 2/14
without notice, the specifications given in this document. 2014 Norgren Switzerland
SPCH/100034
Silencer (T31BA800)
F
D 9
17
73
B
50
C
B C D F
R1 1/4 220 16 54,5
Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes
systems only. Do not use these products where pressures and of all component parts used in pneumatic systems and to provide
temperatures can exceed those listed under Technical features. adequate safeguards to prevent personal injury or damage to
equipment in the event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in
for non-industrial applications, life-support systems, or other ap- the system instructional manual if protection against
plications not within published specifications, consult NORGREN. a failure mode cannot be adequately provided.
System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in warnings found in instruction sheets packed and shipped with
fluid power systems can fail in various modes. these products.
2/14 2013-5328b Our policy is one of continued research and development. We therefore reserve the right to amend, N/fb/en 5.25.100.05
without notice, the specifications given in this document. 2014 Norgren Switzerland