Académique Documents
Professionnel Documents
Culture Documents
Transmission System
V100R006C00
Product Overview
Issue 02
Date 2012-07-31
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
Figure 1-1 Product positioning and typical application of the OptiX OSN 550
Convergence/
Access layer Convergence node
Backbone layer
E1/T1
E1/T1 STM-1/
STM-4
FE
E1/T1 TDM network
FE
E1/T1 STM-1/
STM-4 FE/
GE
ATM/IMA FE/ Packet
E1 GE network
FE/GE
ATM/IMA E1
ATM/IMA E1 FE
FE
OptiX OSN 550 OptiX OSN 3500 NodeB BTS RNC BSC
Hierarchical OAM
The OptiX OSN equipment supports ETH OAM, MPLS OAM, and MPLS-TP OAM.
Hierarchical OAM provides Ethernet services with complete maintenance methods. Figure
1-2 shows the application of hierarchical OAM.
P
P
CE1
PE2 CE3
PE1
PSN
CE2 P
P
CE4
CE PE P P PE CE
MPLS/MPLS-TP
Tunnel
Tunnel OAM
Layer
PW MPLS/MPLS- TP PW OAM
Layer
Ethernet Ethernet
ETH Port OAM
Port OAM Ethernet Service OAM
Layer
: MEP
: MIP
Extreme operating indicates that the continuous operating time of the equipment does not exceed 4 hours
and the accumulated annual operating time does not exceed 90 days.
2 Quick Reference
This chapter describes the product overview, including product photos, hardware, software,
and functions and features.
Table 2-1 lists the overview of the OptiX OSN 550.
Item Description
Appearan
ce
Board PCX/CXL/MD1/EM6T/EM6F/EF8F/EG4C/EFS8/EGT1/SL1D/SL4D/SL1Q/
SP3D/PL3T/DMD2/AUX/PIU/APIU/UPM/FAN
Packet See Table 2-2.
functions
and
features
TDM See Table 2-3.
functions
and
features
Packet 60/40/20 Gbit/s
switching
capacity
TDM Higher order cross-connect capacity: 20 Gbit/s
cross-con Lower order cross-connect capacity: 5 Gbit/s
nect
capacity
Equipmen 1+1 backup for power supply
t-level 1+1 backup between active and standby system control, switching, and
protection timing boards
Fan protection (The failure in a single fan does not affect the operation of
Item Description
the other fans.)
Intelligent Supports intelligent fan speed adjustments and fan shut-down at low
fans temperature. When the ambient temperature is lower than a threshold
(determined by the actual ambient temperature and fan gear interval), fans
automatically work at the lowest gear.
Managem Interface Type Description Connector
ent ports
and External clock 120-ohm external RJ45
auxiliary port clock port, which can
ports work in 2048 kbit/s
mode or 2048 kHz
mode
Power supply Power supply port 2 mm HM connector
port connecting to two
-48/-60 V DC power
supplies
Two 110 V/220 V AC Three-phase socket
power supply ports
Network Ethernet NM port/NM RJ45
management port serial port, which is
connected to a
network management
system (NMS)
Alarm 6-input/2-output alarm RJ45
input/output port port
64 kbit/s One 64 kbit/s RJ45
synchronous synchronous serial
transparent data port or one 19.2 kbit/s
port or 19.2 asynchronous serial
kbit/s port, which
asynchronous transparently transmits
transparent data one channel of data
port services
Orderwire phone Used to provide voice RJ45
port communication for
operation/maintenance
engineers at different
workstations.
Item Description
MPLS The packet switching unit of the PCX board works with a service board to implement MPLS
functions functions.
Item Description
Setup mode: static tunnels
Protection: 1:1 tunnel APS
OAM: supports MPLS tunnel OAM and MPLS-TP tunnel OAM. MPLS tunnel OAM
complies with ITU-T Y.1711, and MPLS-TP tunnel OAM complies with ITU-T
G.8113.1.
Maximum number of MPLS tunnels
Unidirectional: 1K
Bidirectional: 512
Maximum number of tunnel bandwidth: 10 Gbit/s
Maximum number of QinQ links: 1K
NOTE
Unidirectional and bidirectional MPLS tunnels share tunnel resources. One bidirectional MPLS tunnel is
equivalent to two unidirectional MPLS tunnels.
The sum of PW count and MPLS tunnel count must not exceed 1K. PW count and MPLS tunnel count,
however, can be 1K simultaneously if each MPLS tunnel carries one PW. This is because if an MPLS
tunnel carries PWs, the MPLS tunnel is not counted and only the carried PWs are counted.
PWE3 The packet switching unit of the PCX board works with a service board to implement PWE3
functions functions.
Service categories
TDM PWE3 (CES) services
ATM PWE3 services
ETH PWE3 services
Setup mode: static PWs
Protection: 1:1 PW APS
OAM: supports MPLS PW OAM and MPLS-TP PW OAM. MPLS PW OAM complies
with ITU-T Y.1711, and MPLS-TP PW OAM complies with ITU-T G.8113.1.
Supports MS-PWs.
Supports configurable bandwidth.
Maximum number of static PWs: 1K
Maximum number of PW bandwidth: 10 Gbit/s
Maximum number of static MS-PWs: 128
NOTE
The sum of PW count and MPLS tunnel count must not exceed 1K. PW count and MPLS tunnel count,
however, can be 1K simultaneously if each MPLS tunnel carries one PW. This is because if an MPLS
tunnel carries PWs, the MPLS tunnel is not counted and only the carried PWs are counted.
Item Description
MTU length: 960 bytes to E-FX
9600 bytes (1620 bytes, by 100BAS
default) E-LX
MPLS function support 100BAS
VLAN function support. E-VX
The VLAN IDs range from 100BAS
1 to 4094. E-ZX
QinQ support
10GE 10GBAS LC
Number of static MAC (optical E-SR
addresses supported by a port) (LAN)
private network: 512
PCXLX/ 10GBAS
Number of MAC addresses PCXX: E-SW
supported by a device: 16K 2 (WAN)
E-Line services based on 10GBAS
PORT, PORT+VLAN, E-LR
PORT+VLAN+PRI, or (LAN)
PORT+QinQ; E-Line
10GBAS
services carried by PWs;
maximum number of E-LW
E-Line services: 1K (WAN)
10GBAS
E-LAN services based on
IEEE 802.1d bridges, IEEE E-ER
802.1q bridges, or IEEE (LAN)
802.1ad bridges; maximum 10GBAS
number of E-LAN services: E-EW
1; maximum number of (WAN)
logical ports: 1K 10GBAS
E-ZR
(LAN)
10GBAS
E-ZW
(WAN)
GE (optical 1000BA LC
port) SE-SX
PCXLG/ 1000BA
PCXGA SE-LX
/PCXG 1000BA
B: 22 SE-VX
1000BA
SE-ZX
GE 1000BASE- RJ-45
(electrical T
port): 20
CES service Maximum number of CES 192xE1 75/120-ohm Anea 96
services: 192 smart E1
Service category: port
Item Description
point-to-point service
Encapsulation types:
CESoPSN
SAToP
Compression of idle
timeslots: supported (only
for CESoPSN
encapsulation)
Jitter buffer time: 375 us to
16000 us
Packet loading time: 125 us
to 5000 us
CES ACR: supported
ATM/IMA Maximum number of ATM 192xE1 75/120-ohm Anea 96
service services smart E1
Local: 128 port
Remote: 256
Maximum number of ATM
connections
Local: 512
Remote: 1K
ATM traffic management
ATM encapsulation format
N-to-one VPC
N-to-one VCC
One-to-one VPC
One-to-one VCC
Maximum number of
concatenated ATM cells:
31
ATM OAM: F4 (VP layer)
and F5 (VC layer)
Maximum number of IMA
groups: 32
Maximum number of
members in an IMA group:
16
MPLS tunnel APS and MPLS-TP tunnel APS share 64 protection group resources.
Item Description
PW APS Maximum number of protection groups: 64
Maximum number of members bound into a PW: 512
Switching duration: 50 ms (one protection pair containing eight
members, six PW APS protection groups)
NOTE
Tunnel APS and PW APS share 64 protection group resources.
MSTP Supports the MSTP protocol that generates only the CIST. The MSTP
protocol provides functions equivalent to those of the RSTP protocol.
ERPS Supports ERPS that complies with ITU-T G.8032/Y.1344.
Maximum number of protection groups: 8
Switching duration: 50 ms at an optical port and 2s at an electrical port
if the number of nodes on a ring network is not more than 16 and the link
is faulty bidirectionally
LPT Maximum number of services that support LPT: 16
Point-point and point-multipoint LPT
Switching duration:
300 ms if the fault is on the NNI side and is detected using PW OAM
300 ms at an optical port and 3s at an electrical port if the fault is
on the UNI side
LAG LAG protection
A maximum of 16 LAGs. Each LAG has a maximum of eight members.
Switching duration:
Manual/Static LAG: 50 ms at an optical port and 2s at an electrical
port if the link is interrupted bidirectionally
Static LAG: 3s if the link is interrupted unidirectionally
Item Description
Delay measurement (DM)
Supports the following Ethernet port OAM functions:
OAM auto-discovery
Link performance monitoring
Fault detection
Remote loopback
Self-loop detection and looped-port blocking
Maximum number of MDs/MAs/MEPs: 64
NOTE
ETH-OAM and MPLS/MPLS-TP OAM share 128 OAM resources.
Only the E-Line service transmitted in native Ethernet mode supports ETH-LM and
ETH-DM.
ATM OAM Supports the following ATM OAM functions: CC, LB, RDI, and AIS.
RMON Supports port-level and service-level RMON functions, in compliance with
RFC 2819. Supports four RMON management groups: Ethernet statistics
group, Ethernet history group, Ethernet alarm group, and Ethernet history
control group.
Port level:
Basic Ethernet performance
Extended Ethernet performance
Service level:
L2VPN (private line service)
Transit tunnel
PW
PRBS Supports PRBS tests for lower order services.
Synchronizati Synchronou Synchronous Ethernet that complies with ITU-T G.8261 and ITU-T
on s Ethernet G.8262.
clock Port receiving/transmitting synchronous Ethernet clocks: FE/GE/10GE
Input/Output of SSM packets
Clock frequency stability (holdover mode): < 50 ppb
NOTE
SFP electrical modules do not support synchronous Ethernet clocks.
When working in 10BASE-T mode, FE/GE ports do not support synchronous Ethernet
clocks.
IEEE The OptiX OSN 550 provides two 1PPS+ToD external time ports that
1588v2 support compensation for propagation delay on their connected cables. The
compensation can be set to a value within the range from 0 to 10 us in
steps of not more than 10 ns. ToD supports cyclic redundancy checks
(CRCs).
The input/output mode at the two external time ports can be set.
The two external time ports form active/standby protection. If the time
signals from one port fail, the equipment automatically adopts the time
Item Description
signals from the other port.
NOTE
A port in 10GE WAN mode does not support IEEE 1588v2.
Item Description
Item Description
optical ports
14xSTM-4 S-4.1, L-4.1 LC
and L-4.2
optical ports
2xSTM-16 S-16.1, LC
L-16.1 and
L-16.2 optical
ports
PDH service 252xE1/T1 E1 Anea 96
(75/120-ohm)
/T1
(100-ohm)
electrical
ports
18xE3/T3 E3 SMB
(75-ohm)/T3
(75-ohm)
electrical
ports
Ethernet Supports the following 48xFE 10/100BASE- RJ45
service Ethernet services: T(X)
Ethernet private line (EPL) 6xGE 1000BAS LC
services E-SX/LX/
Ethernet virtual private line VX/ZX
(EVPL) services 1000BAS
Ethernet private LAN E-T
(EPLAN) services
Ethernet virtual private
LAN (EVPLAN) services
Item Description
impedance is 120 ohms or 75 ohms (a converter can be used to provide a 75-ohm clock port).
Non-synchronization status message (SSM), standard SSM, and extended SSM protocols
Tributary retiming
Locked mode, holdover mode, and free-run mode
Power
supply -48 V/-60 V DC
unit 110 V/220 V AC
TDM
cross- Packet
connect switching
Fan
unit unit
unit
VC-4 Ethernet
signal signal
FE/GE/10GE Clock
Service External clock
E1 (CES/ATM/IMA) unit
STM-1/4/16 interface
E1 (TDM)/T1/E3/T3 unit
Auxiliary Orderwire
NMS External alarm
interface
unit Synchronous/Asynchronous data
Backplane
Table 3-3 Access capacities of the OptiX OSN 550 in packet mode
Board 10GE GE GE FE FE E1
(Optical (Optical (Electrica (Optical (Electrica (ATM/I
Port) Port) l Port) Port) l Port) MA/CES)
PCXLX 2 20 20 48 36 192
PCXX 2 20 20 48 36 192
PCXLG 0 22 20 48 36 192
PCXGA 0 22 20 48 36 192
PCXGB 0 22 20 48 36 192
Table 3-4 Access capacities of the OptiX OSN 550 in TDM mode
H Board
installation
area
D W
SLOT
SLOT SLOT
SLOT 7
7 (CST/CSH) SLOT
SLOT 8
8 (CST/CSH)
91 SLOT
10
(PIU) SLOT
(PIU) SLOT
SLOT 5 (EXT)
5 (EXT) SLOT
SLOT 66 (EXT)
(EXT)
1 93
11
SLOT
SLOT (FAN)
(FAN) SLOT
SLOT 3 (EXT)
3 (EXT) SLOT
SLOT 4 (EXT)
4 (EXT)
929
(PIU)
(PIU) SLOT
SLOT 1 (EXT )
1 (EXT) SLOT
SLOT 2 (EXT)
2 (EXT )
2
3
An OptiX OSN 550 NE can automatically save its NE ID, extended ID, IP address, and subnet mask to
its backplane. After a new system control, switching, and timing board replaces an original one, the NE
automatically uses the saved information. Therefore, you do not need to set the NE ID, extended ID, IP
address, and subnet mask for the substitute board.
Ventilation Design
The chassis is densely covered with small air holes. Through these holes, air is let in from the
left and out from the right by fans.
Ensure the smooth flow of air inside and around the equipment. Do not block the air intake vents and air
exhaust vents of subracks when cabling. Keep the top of subracks clean.
AIR IN
Label Description
Table 4-1 provides the description of the labels on the chassis and boards. Actual labels may
vary depending on the configurations of the chassis and boards.
HUAWEI
HUAWEI TECHNOLOGIES CO.,LTD. MADE IN CHINA
AC power
Figure 4-2 Access capacities of slots when PCXLX/PCXX boards are installed on the OptiX OSN
550
SLO SLOT 7
SLOT SLOT 7 10Gbit/s SLOT SLOT
8 10Gbit/s
8 (CST/CSH)
T (CST/CSH)
1
91
0 SLOT
SLO
(PIU SLOT 5 SLOT 6
(PIU) T SLOT 5 4Gbit/s SLOT 6
) (EXT) (EXT)4Gbit/s
1
93
1
SLO SLOT 3 SLOT 4
SLOT (FAN)
T SLOT 3 (EXT) 4Gbit/s SLOT 4 (EXT)4Gbit/s
929
(PIU SLOT 1 SLOT 2
(PIU) SLOT 1 ) )
) (EXT 10Gbit/s SLOT 2 (EXT10Gbit/s
Figure 4-3 provides access capacities of slots when PCXGB/PCXLG boards are installed on
the OptiX OSN 550.
Figure 4-3 Access capacities of slots when PCXLG/PCXGB boards are installed on the OptiX
OSN 550
SLO SLOT1Gbit/s
7
SLOT SLOT 7 SLOT SLOT
8 1Gbit/s
8 (CST/CSH)
T (CST/CSH)
1
91
0 SLOT
SLO
(PIU SLOT 5 SLOT 6
(PIU) T SLOT 5 4Gbit/s SLOT 6
) (EXT) (EXT)4Gbit/s
1
93
1
SLO SLOT 3 SLOT 4
SLOT (FAN)
T SLOT 3 (EXT) 4Gbit/s SLOT 4 (EXT)4Gbit/s
929
(PIU SLOT 1 SLOT 2
(PIU) SLOT 1 ) )
) (EXT 10Gbit/s SLOT 2 (EXT10Gbit/s
Figure 4-4 provides access capacities of slots when PCXGA boards are installed on the OptiX
OSN 550.
Figure 4-4 Access capacities of slots when PCXGA boards are installed on the OptiX OSN 550
SLO SLOT 7
SLOT SLOT 7 1Gbit/s SLOT SLOT
8 1Gbit/s
8 (CST/CSH)
T (CST/CSH)
1
91
0 SLOT
SLO
(PIU SLOT 5 SLOT 6
(PIU) T SLOT 5 4Gbit/s SLOT 6
) (EXT) (EXT)4Gbit/s
1
93
1
SLO SLOT 3
SLOT (FAN) SLOT 4
T SLOT 3 (EXT) 4Gbit/s SLOT 4 (EXT)4Gbit/s
929
(PIU SLOT 1 SLOT 2
(PIU) SLOT 1 ) )
) (EXT 2.5Gbit/s SLOT 2 (EXT2.5Gbit/s
Power Consumption
Maximum power consumption: 240 W
Typical power consumption: 149 W
Board configuration for typical power consumption: 2 x PCXLX + 3 x EM6F + 1 x MD1
+ 1 x FAN + 2 x PIU.
As shown in the following figure.
SLOT
SLOT SLOT 7 (CST/CSH)
SLOT 7 (PCXLX) SLOT 88(PCXLX)
SLOT (CST/CSH)
91
10
(PIU) SLOT
(PIU) SLOT SLOT 5 (EXT) SLOT 6 (EXT)
93
11
SLOT
SLOT (FAN)
(FAN) SLOT
SLOT 33(EXT)
(MD1) SLOT 4 4(EM6F)
SLOT (EXT)
92
9
(PIU)
(PIU) SLOT 11(EXT
SLOT )
(EM6F) SLOT
SLOT 2 2(EF6F)
(EXT )
Heat Consumption
Maximum heat consumption: 819 BTU/h
Typical heat consumption: 485 BTU/h
In the case of OptiX OSN 550 equipment, power consumption is generally transformed into heat
consumption. Hence, heat consumption (BTU/h) and power consumption (W) can be converted to each
other in the formula: Heat consumption (BTU/h) = Power consumption (W) / 0.2931 (Wh).
Board Board Board Name Function Service Category Port Type Vali
Classifi Acron d
cation ym Slot
System TNM1 Cross-connect Supports Native Ethernet One Ethernet Slots
control, PCXL , timing, a packet services NM port/NM 7 and
switchin X system switchin Point-to-point serial port 8
g, and control, and g transparent (sharing one
timing line board capacity transmission RJ45 port)
board of 60 E-Line services One
(Hybrid) Gbit/s. STM-1/STM-4/S
VLAN-based
Supports TM-16 SFP
E-Line services
a higher optical port. The
order QinQ-based optical port type
cross-co E-Line services can be S-1.1,
nnect E-LAN services L-1.1, L-1.2,
capacity based on IEEE S-4.1, L-4.1,
of 20 802.1d bridges L-4.2, S-16.1,
Gbit/s E-LAN services L-16.1, or
and a based on IEEE L-16.2.
lower 802.1q bridges One 10GE (XFP)
order optical port:
cross-co E-LAN services
based on IEEE 10GBASE-SR
nnect (LAN),
Board Board Board Name Function Service Category Port Type Vali
Classifi Acron d
cation ym Slot
capacity 802.1ad bridges 10GBASE-SW
of 5 ETH PWE3 services (WAN),
Gbit/s. 10GBASE-LR
STM-1/STM-4/STM-
Performs (LAN),
16 services 10GBASE-LW
system
commun (WAN),
ication 10GBASE-ER
and (LAN),
control. 10GBASE-EW
(WAN),
10GBASE-ZR
(LAN), or
10GBASE-ZW
(WAN)
TNM1 Cross-connect Supports Native Ethernet One Ethernet Slots
PCXX , timing, a packet services NM port/NM 7 and
system switchin Point-to-point serial port 8
control, and g transparent (sharing one
line board capacity transmission RJ45 port)
of 60 E-Line services One 10GE (XFP)
Gbit/s. optical port:
VLAN-based
Supports 10GBASE-SR
E-Line services
a higher (LAN),
order QinQ-based 10GBASE-SW
cross-co E-Line services (WAN),
nnect E-LAN services 10GBASE-LR
capacity based on IEEE (LAN),
of 20 802.1d bridges 10GBASE-LW
Gbit/s E-LAN services (WAN),
and a based on IEEE 10GBASE-ER
lower 802.1q bridges (LAN),
order 10GBASE-EW
cross-co E-LAN services (WAN),
nnect based on IEEE 10GBASE-ZR
capacity 802.1ad bridges (LAN), or
of 5 ETH PWE3 services 10GBASE-ZW
Gbit/s. (WAN)
Performs
system
commun
ication
and
control.
TNM1 Cross-connect Supports Native Ethernet One Ethernet Slots
PCXL , timing, a packet services NM port/NM 7 and
G system switchin Point-to-point serial port 8
control, and g transparent (sharing one
line board capacity transmission RJ45 port)
of 40 One
Board Board Board Name Function Service Category Port Type Vali
Classifi Acron d
cation ym Slot
Gbit/s. E-Line services STM-1/STM-4/S
Supports VLAN-based TM-16 SFP
a higher E-Line services optical port. The
order optical port type
QinQ-based can be S-1.1,
cross-co E-Line services
nnect L-1.1, L-1.2,
capacity E-LAN services S-4.1, L-4.1,
of 20 based on IEEE L-4.2, S-16.1,
Gbit/s 802.1d bridges L-16.1, or
and a E-LAN services L-16.2.
lower based on IEEE One GE (SFP)
order 802.1q bridges optical port:
cross-co E-LAN services 1000BASE-SX/1
nnect based on IEEE 000BASE-LX/10
capacity 802.1ad bridges 00BASE-VX/10
of 5 00BASE-ZX
ETH PWE3 services
Gbit/s.
STM-1/STM-4/STM-
Performs
system 16 services
commun
ication
and
control.
TNM1 Cross-connect Supports Native Ethernet One Ethernet Slots
PCXG , timing, a packet services NM port/NM 7 and
A system switchin Point-to-point serial port 8
control, and g transparent (sharing one
line board capacity transmission RJ45 port)
of 20 E-Line services One GE (SFP)
Gbit/s. optical port:
VLAN-based
Supports 1000BASE-SX/1
E-Line services
a higher 000BASE-LX/10
order QinQ-based 00BASE-VX/10
cross-co E-Line services 00BASE-ZX
nnect E-LAN services
capacity based on IEEE
of 20 802.1d bridges
Gbit/s E-LAN services
and a based on IEEE
lower 802.1q bridges
order
cross-co E-LAN services
nnect based on IEEE
capacity 802.1ad bridges
of 5 ETH PWE3 services
Gbit/s.
Performs
system
commun
Board Board Board Name Function Service Category Port Type Vali
Classifi Acron d
cation ym Slot
ication
and
control.
TNM1 Cross-connect Supports Native Ethernet One Ethernet Slots
PCXG , timing, a packet services NM port/NM 7 and
B system switchin Point-to-point serial port 8
control, and g transparent (sharing one
line board capacity transmission RJ45 port)
of 40 E-Line services One GE (SFP)
Gbit/s. optical port:
VLAN-based
Supports 1000BASE-SX/1
E-Line services
a higher 000BASE-LX/10
order QinQ-based 00BASE-VX/10
cross-co E-Line services 00BASE-ZX
nnect E-LAN services
capacity based on IEEE
of 20 802.1d bridges
Gbit/s E-LAN services
and a based on IEEE
lower 802.1q bridges
order
cross-co E-LAN services
nnect based on IEEE
capacity 802.1ad bridges
of 5 ETH PWE3 services
Gbit/s.
Performs
system
commun
ication
and
control.
System TNM1 Cross-connect Supports STM-1 services One Ethernet Slots
control, CXL1 , timing, a higher NM port/NM 7 and
switchin system order serial port 8
g, and control, and cross-co (sharing one
timing line board nnect RJ45 port)
board capacity One STM-1
(TDM) of 20 optical port of
Gbit/s the S-1.1 and
and a L-1.1 types
lower
order
cross-co
nnect
capacity
of 5
Gbit/s.
Performs
Board Board Board Name Function Service Category Port Type Vali
Classifi Acron d
cation ym Slot
system
commun
ication
and
control.
TNM1 Cross-connect Supports STM-4 services One Ethernet Slots
CXL4 , timing, a higher NM port/NM 7 and
system order serial port 8
control, and cross-co (sharing one
line board nnect RJ45 port)
capacity One STM-4
of 20 optical port of
Gbit/s type S-4.1 or
and a L-4.1
lower
order
cross-co
nnect
capacity
of 5
Gbit/s.
Performs
system
commun
ication
and
control.
TNM1 Cross-connect Supports STM-16 services One Ethernet Slots
CXL16 , timing, a higher NM port/NM 7 and
system order serial port 8
control, and cross-co (sharing one
line board nnect RJ45 port)
capacity One STM-16
of 20 optical port of
Gbit/s the S-16.1,
and a L-16.1, and
lower L-16.2 types
order
cross-co
nnect
capacity
of 5
Gbit/s.
Performs
system
commun
ication
and
control.
Board Board Board Name Function Service Category Port Type Vali
Classifi Acron d
cation ym Slot
Packet TNM1 32xSmart E1 Receives/Tr CES E1 services 75/120-ohm E1 port Slots
processi MD1 service ansmits E1 ATM/IMA E1 1 to 6
ng board processing signals. services
board
TNM1 6xRJ45 Receives/Tr Native Ethernet Four FE Slots
EM6T FE/GE ansmits services electrical ports: 1 to 6
processing FE/GE Point-to-point 10/100BASE-T(
board service transparent X)
signals and transmission Two GE
works with E-Line services electrical ports
the packet (they can serve
switching VLAN-based
E-Line services as FE electrical
unit to ports):
process the QinQ-based 1000BASE-T
received E-Line services
TNM1 4xRJ45 and FE/GE E-LAN services Four FE Slots
EM6F 2xSFP FE/GE service based on IEEE electrical ports: 1 to 6
processing signals. 802.1d bridges 10/100BASE-T(
board X)
E-LAN services
Two ports that
based on IEEE
802.1q bridges use any of the
following types
E-LAN services of SFP modules:
based on IEEE 1000BASE-SX/1
802.1ad bridges 000BASE-LX/10
ETH PWE3 services 00BASE-VX/10
00BASE-ZX/100
0BASE-T
(compatible with
FE electrical
ports)/100BASE-
BX/100BASE-F
X/100BASE-LX/
100BASE-VX/1
00BASE-ZX
TNM1 4xGE Receives/Tr Native Ethernet Four GE Slots
EG4C (SFP/RJ45) ansmits GE services electrical ports: 3 to 6
processing service Point-to-point 1000BASE-T
board signals and transparent Four GE/FE
works with transmission optical ports
the packet E-Line services (using SFP
switching optical modules):
unit to VLAN-based
E-Line services 1000BASE-SX/1
process the 000BASE-LX/10
received GE QinQ-based 00BASE-VX/10
service E-Line services 00BASE-ZX/100
signals. E-LAN services BASE-BX/100B
based on IEEE ASE-FX/100BA
SE-LX/100BAS
Board Board Board Name Function Service Category Port Type Vali
Classifi Acron d
cation ym Slot
802.1d bridges E-VX/100BASE-
E-LAN services ZX
based on IEEE
802.1q bridges
E-LAN services
based on IEEE
802.1ad bridges
ETH PWE3 services
TNM1 8xFE Receives/Tr Native Ethernet Eight FE optical Slots
EF8F processing ansmits FE services ports: 1 to 6
board service Point-to-point 100BASE-BX/100B
signals and transparent ASE-FX/100BASE-
works with transmission LX/100BASE-VX/1
the packet E-Line services 00BASE-ZX
switching
unit to VLAN-based
process the E-Line services
received FE QinQ-based
service E-Line services
signals. E-LAN services
based on IEEE
802.1d bridges
E-LAN services
based on IEEE
802.1q bridges
E-LAN services
based on IEEE
802.1ad bridges
ETH PWE3 services
SDH TNH2 2xSTM-1 Receives/Tr STM-1 services Two STM-1 optical Slots
board SL1D interface ansmits ports of the S-1.1, 1 to 6
board 2xSTM-1 L-1.1, and L-1.2
optical types
signals.
TNH2 2xSTM-4 Receives/Tr STM-4 services Two STM-4 optical Slots
SL4D interface ansmits ports of the S-4.1, 1 to 6
board 2xSTM-4 L-4.1, and L-4.2
optical types
signals.
TNH2 4xSTM-1 Receives/Tr STM-1 services Four STM-1 optical Slots
SL1Q interface ansmits ports of the S-1.1, 1 to 6
board 4xSTM-1 L-1.1, and L-1.2
optical types
signals.
PDH TNH2 42xE1/T1 Receives/Tr E1/T1 services Forty-two Slots
Board Board Board Name Function Service Category Port Type Vali
Classifi Acron d
cation ym Slot
board SP3D tributary ansmits 75/120-ohm E1 1 to 6
board E1/T1 ports or forty-two
signals. 100-ohm T1 ports
TNH2 3xE3/T3 Receives/Tr E3/T3 services Three 75-ohm E3/T3 Slots
PL3T tributary ansmits ports 1 to 6
board E3/T3
signals.
EoS TNH2 8xFE Receives/Tr EPL services Eight FE electrical Slots
board EFS8 switching and ansmits EVPL services ports: 1 to 6
processing 8xFE 10/100BASE-T(X)
EPLAN services
board signals.
EVPLAN services
TNH2 1xGE Receives/Tr EPL services One GE Slots
EGT1 transparent ansmits EVPL services optical/electrical 1 to 6
transmission 1xGE port (SFP):
EPLAN services
board signals. 1000BASE-SX
EVPLAN services
1000BASE-LX
1000BASE-VX
1000BASE-ZX
1000BASE-T
WDM TNM1 2-port optical Applicable N/A wIN/wOUT slot 1
board DMD2 add/drop to both the wA1/wA2 to 6
multiplexing CWDM and
wD1/wD2
board DWDM
systems, the eIN/eOUT
TNF1DMD eA1/eA2
2
eD1/eD2
adds/drops
two
wavelengths
of signals
to/from the
multiplexed
wavelength
in the east
and west
directions.
Auxiliar TNM1 Auxiliary Provides the Orderwire services One orderwire Slots
y AUX interface system with Synchronous data phone port 1 to 6
interface board one services One
board orderwire asynchronous
Asynchronous data
phone port, data port
one services
One synchronous
synchronou
s data port data port
or 6-input/2-output
Board Board Board Name Function Service Category Port Type Vali
Classifi Acron d
cation ym Slot
asynchrono alarm port
us data port, One 2-channel
6-input/2-ou external clock
tput alarm port
ports, one
Two 2-channel
2-channel
external external time
clock port, ports
and two
2-channel
external
time ports.
Power UPM Uninterruptibl Provides N/A Provides two 48 V slot
supply e power access to DC power supply 97
board module one 110 ports.
V/220 V
AC power
supply.
TND1 Power supply Provides N/A -48 V/-60 V DC Slots
PIU board one -48 power supply ports 91
V/-60 V DC and
power 92
supply.
TNF1 Power supply Provides N/A 100 V/240 V AC Sl
APIU board 110 V/220 power supply ports ot
V AC s
power 4
supplies. an
d
6
(r
ec
o
m
m
en
de
d)
Sl
ot
s
2
an
d
4
Fan TNM1 Fan board Cools the N/A N/A Slot
board FAN NE. 93
Table 5-1 Network topologies supported by OptiX OSN 550s and corresponding legends
Network Legend
Topology
Chain
Ring
Tangent rings
FE
TDM E1
FE NE2
FE
NE1 NE3
TDM E1
NE4
ATM/IMA E1
PCXLG PCXLG
NE6
EM6T SP3D
NE2
E1
FE FE
NE1
PCXLG PCXLG NE3
NE6 PCXLG PCXLG
EM6T SP3D NE6
EF8F
E1
FE
NE4
PCXLG PCXLG
NE6
MD1
ATM/IMA E1
FE
NE5
ATM/IMA E1 FE
GE
GE NE2
NE1 NE3 FE
TDM E1 GE NE4 GE
TDM E1
NodeB BTS
PCXGB
FE NE6
EF8F MD1
ATM/IMA E1 NE2
PCXGB PCXGB
NE6
FE
EM6F
NE1
NE3
PCXGB PCXGB PCXGB PCXGB
NE6 FE NE6
MD1
NE4 EM6F
E1 PCXGB PCXGB
GE
FE
ISU2
MD1
E1
NodeB BTS
TDM E1 FE
NE1
FE
FE
TDM E1
NE 2 NE4
TDM E1
NE 3
FE TDM E1
BTS NodeB
FE E1
FE NE2 NE4
PCXLG PCXLG PCXLG PCXLG
NE6 NE6
EFS8 SP3D EFS8 SP3D
E1
E1
FE
NE3
PCXLG PCXLG
NE6
EFS8 SP3D
FE E1
BTS NodeB
Primary Secondary
U2000 U2000
External DCN
Router Switch
NON-GNE
NON-GNE
Site D
Site E
GNE
GNE
Site A
Site C
Master
NON-GNE
Site F
U2000
NON-GNE
Slave Slave Web LCT
Site B
Figure 6-1 illustrates a network that has Huawei equipment deployed at different layers: NEs at sites
A-D are OptiX OSN 8800 NEs, NEs at site E are OptiX OSN 1800 NEs, and NEs at site F are OptiX
OSN 550/500 NEs.
In Figure 6-1,
Network management system: U2000 and U2000 LCT
Inter-NE communication management:
The NEs at sites A and C are gateway NEs (GNEs) and are connected to the external DCN through a switch
or router. All the other NEs are non-GNEs that communicate with the NMS through GNEs.
The NEs between sites A and D are connected with fibers and use the HWECC or IP over DCC protocol to
exchange information over ESC/OSC channels.
The NEs between sites E and C are connected with fibers and use the HWECC or IP over DCC protocol to
exchange information over ESC channels.
The NEs between sites F and C are connected with fibers and use the HWECC or IP over DCC protocol to
exchange information over inband channels.
Some NEs between sites A and F (NEs connected to an optical or electrical transmission device, such as
NEs at site B) are connected with network cables, and use the HWECC or IP over DCC protocol to
exchange information over Ethernet channels (at NM_ETH ports).
Intra-NE communication management: The master and slave subracks implement
intra-NE communication for each NE at sites A-D. One NE at site A has three subracks
(one master is connected to two slaves).
Network management involves the following aspects:
Table 6-1 DCN solutions that the OptiX OSN 550 supports
Routine equipment maintenance and troubleshooting are essential to ensure that a network
runs properly. The OptiX OSN 550 provides strong maintenance capabilities.
Table 7-1 lists the maintenance functions that the OptiX OSN 550 supports.
Table 7-1 Maintenance functions that the OptiX OSN 550 supports
8 Technical Specifications
Item Description
Dimensions 88 mm x 442 mm x 220 mm (H x W x D)
Weight 3.5 kg (net weight of a chassis that contains one fan board and two PIU
boards)
Power Maximum power consumption: 240 W
consumptio Typical power consumption: 149 W
n
Board configuration for typical power consumption: 2 x PCXLX + 3 x
EM6F + 1 x MD1 + 1 x FAN + 2 x PIU.
Heat Maximum heat consumption: 819 BTU/h
consumptio
Item Description
n Typical heat consumption: 485 BTU/h
Power DC power supply
supply Rated voltage: -48 V or -60 V
performanc
e Voltage range: -38.4 V to -72 V
AC power supply
Rated voltage: 110 V or 220 V
Voltage range: 100 V to 240 V
Fuse DC power supply: 20 A
capacity AC power supply: 5 A
Electromag Complies with EMC Class A.
netic
compatibilit
y
Predicted System availability: 0.9999965
reliability Annual average repair rate: < 1.5%
Mean time to repair (MTTR): 1 hour
Mean time between failures (MTBF): 33.08 years
Table 8-2 Power consumption and weight of each board that the OptiX OSN 550 supports
EF8F 23 0.55
EG4C 4xGE optical ports: 12.5 0.45
4xGE electrical ports: 11.0
SL1D 3.5 0.30
SL4D 3.7 0.30
SL1Q 4.5 0.30
SP3D 11.9 0.85
PL3T 4.5 0.30
EFS8 13.0 0.65
EGT1 8.3 0.60
DMD2 0.5 0.72
AUX 2.2 0.30
PIU 0.5 0.12
APIU 20.0 1.93
FAN 12.0 0.30