FORKLIFT BATTERY CHARGING SAFETY

Regardless of the type of electric material handling equipment you use, such as

forklifts, pallet jacks, rider pallet jacks, walkie stackers, personnel carts or others, one

thing is certain and that's battery charging.

In this program we want to emphasize that each equipment and battery manufacturer

has its own specific maintenance and operating procedures and these should be

followed at all times.

Your company has specific rules and procedures and these should also be followed.

The information in this program has been taken from a variety of sources, a variety of

manufacturers and information used by many companies with excellent maintenance

practices. It's a review of the basics of charging batteries, regardless of the type

equipment used, however, it's up to each individual to follow your company's rules

and procedures when charging batteries.

Ok, let's begin the program by reviewing some basic tips for handling industrial

equipment batteries. The first rule is to always wear personal protective equipment,

which includes rubber apron, gloves, boots and face/eye protection when handling,

checking, filling, charging or repairing batteries. Electrolyte used in the batteries is a

mixture of sulfuric acid and water and is quite caustic which can easily burn your skin.

Keep open flames away from batteries and never try to check the electrolyte level with

a cigarette lighter or match. Use a non-sparking flashlight or other approved lighting

and do not smoke or create sparks near batteries. The space between the underside

of the cover and the top of the electrolyte in the cell usually contains a hydrogen-

oxygen mixture which is explosive when ignited. Make sure you charge batteries only

in those areas approved for battery charging and is well ventilated.

Be prepared for an electrolyte spill and have adequate water available to flush your

skin or other affected area with water. Volumes of water applied quickly and
continuously will prevent serious injury to the skin. Quick medical attention is

necessary to assure proper care and treatment.

Splashes to the eyes can be avoided by wearing proper eye/face protection, however,

if electrolyte is splashed into the eyes, wash the eyes with water for 15 minutes and

get immediate medical attention. Spills should be cleaned up immediately by using a

strong neutralizer such as baking soda. The baking soda will neutralize the acid and

make it safe to clean or flush from the floor or other surfaces.

When changing or repairing plugs or receptacles that are connected to the charging

equipment, be sure to shut off the power first. This will prevent a short circuit and

arcing of an electrical spark. Arcing can cause an explosion and fire. When mixing acid

to prepare electolyte, ALWAYS POUR THE ACID SLOWLY INTO WATER and never pour

water into the acid. If water is added to acid it will not readily mix and will splash the

acid due to the great difference in the specific gravity of the two liquids. Always store

acid in plastic or glass containers. Always lift batteries with mechanical equipment

such as a hoist, crane or lift truck. Move batteries horizontally with power trucks,

conveyors or rollers. Make sure that hoist hooks, spreader bars and other tools are of

ample strength and properly installed.

Cover the top of batteries with a rubber mat or other insulating material to prevent

external short circuits from chains or cables falling onto the top of the battery. Proper

handling of batteries is essential to prevent injuries and to prevent battery damage or

electrolyte spills.

Make sure that charging plugs and receptacles are properly locked and all other

connections tight, secure and free from friction. A loose connection may mean

sparking or arcing near highly explosive gas mixtures. Enclose all bare wires and bus

bars in the battery room by wire guards, guard rails or other means of isolation from

general plant traffic, as any open, high current transmission equipment is a possible

hazard to you, other workers and the equipment.

Double check to make sure the charger being used matches the voltage and

amperage of the equipment battery. Voltages and amperages are found on the

equipment data plate and on the charger data plate. Before disconnecting or
connecting batteries to a charger, make sure the charger is in the OFF position. If an

attempt is made to do this while the charger is ON, serious injury to you, the battery

and charger could result. Before charging, make sure the battery cells contain the

correct amount of water. Charging batteries with a low water level might result in

damage to the cells. Keep in mind that battery fumes are explosive and to check the

cells with a flashlight or other approved light. Before connecting the battery cable to

the equipment's receptacle, make sure the key switch is off and all controls are in the

off position and the brakes are locked. The battery cable must be fully connected

before the equipment is used. If the plug is not making good contact, heat will weld

the two parts of the battery connector together, making it difficult to remove and

necessary to replace. Battery terminals should be checked and cleaned of any

corrosion.

Good battery terminal contact is essential not only for operation, but also for proper

charging of the battery. The battery cover should be closed except when charging,

then it must be left open. Disconnect the battery from the truck when doing

maintenance and repair work on the motor or electrical system.

Obviously, live current may cause arcing or short circuiting. Never lay metal tools such

as wrenches or other material on top of an open battery. Sparking and short circuiting

will occur and can quickly discharge the battery or may explode. Check batteries for

cracks or leaks and repair them when detected. If batteries are not in use, they should

be kept charged. A freshening charge of about 3 to 4 hours at the finish rate may be

necessary if the specific gravities have fallen 30 points or more.

When recharging a fully discharged battery, the starting charge rate may be 3 to 5

times higher than the finish charge rate indicated on the battery nameplate. The

charge rate should taper down to the finish charge rate by the time the battery is 85

percent charged and may be even lower when fully charged. High "on charge"

temperatures or frequent need to add water are indications of overcharging.

Be sure to follow the equipment manufacturer's instructions on proper battery

charging. The top of the battery should be kept clean and dry. Keep vent caps in place

during use and when charging. Let's stop here a minute because there have been
questions and confusion in the past about the practice of leaving vent caps on or off

during charging. Many years ago, safety rules dictated that vent caps must be left off

during charging, to help dissipate the heat during charging. However, in the past 15 or

so years, engineers and other safety professionals have determined that vent caps

must remain on during charging.

Most manufacturers today also state that vent caps should remain on during

charging. Vent caps must be checked to make sure the vent holes are not plugged and

are functioning properly. The vent caps dissipate heat during charging and allow small

volumes of gas mixtures to escape. If the vent caps are left off, a large volume of

hydrogen gas could escape and build up, creating a greater explosive hazard. It is

clear however, that battery compartment covers must remain open during charging.

When batteries are not mounted on equipment, they should be placed in proper

storage areas, but never stored directly on a cement floor. If necessary, place them on

wooden pallets and store in a dry, moderately cool area. Lead acid batteries will

slowly "self discharge" over a period of time due their chemical makeup. If the self-

charge is left uncontrolled, excessive sulfation can occur which is difficult to reduce

and may damage the plates.

If a greasy film forms on the top of batteries, this is acid and should be neutralized

with a baking soda solution. Keep all batteries in a clean condition. Have we left

anything out?

How about the type of water you should use when filling the battery? The answer is to

always use distilled water. The reason for this is simple. Distilled water removes

impurities in water. Using regular tap water in batteries causes these impurities to

attach themselves to the battery plates during charging, or chemical action and can

cause the battery to decrease it's normal life expectancy. Use distilled or other

approved water when filling batteries. Don't use tap water because it will cause the

life of the battery to be decreased over time. Always follow your equipment

manufacturer's recommendations. Some manufacturers recommend that when your

battery is discharged 85 percent, it's time to get it recharged.


Some manufacturers don't have charge/discharge meters on their equipment. The

moral of the story is to follow the manufacturer's recommendations.

Equipment, battery and charger manufacturer's instructions, combined with your

company's policies and procedures are the best sources of information for safety and

long life of the equipment. If you're not sure about something, ask your supervisor.

The job and the equipment you use is too important to be left to chances.