Vous êtes sur la page 1sur 212

TIDEL Park Coimbatore Ltd

TIDEL PARK COIMBATORE LTD


(A JV of TIDCO, ELCOT, TIDEL & STPI)

RETENDER
INTERNATIONAL TECHNO COMMERCIAL TENDER
FOR CIVIL AND ALLIED WORKS
PART II BILL OF QUANTITIES

FOR CONSTRUCTION OF BUILDING COMPLEX OF INFORMATION TECHNOLOGY


PARK (CIVIL AND ALLIED WORKS) AT VILLANKURICHI (SEZ AREA), COIMBATORE

DUE DATE FOR SUBMISSION: ON OR BEFORE 6th August, 2008 at 15.00 Hours

TO BE SUBMITTED TO:
The Chairman & Managing Director
TIDEL Park Coimbatore Ltd
(First Floor TIDEL Park)
4, Rajiv Gandhi Salai,
Taramani, Chennai - 600 113.
Telephone No.: +91 44 22540500/501
Tax No.: +91 44 22541744

ARCHITECTS & ENGINEERS


M/s C.R. Narayana Rao
Architects & Engineers
#5/10 Karpagambal Nagar,
Luz, Chennai- 600 004 INDIA
Tel No: 044-24991676 (4 lines)
Fax No: 044-24991318
OWNERS ENGINEER
M/s TCE Consulting Engineers Limited
Sheriff Centre 73/1 St Marks Road
Bangalore 560 001.
Ph: 080 66226000
Fax: 080 22274873/74

BID SUBMITTED BY:

M/s._________________________

Address_____________________

____________________________

JULY 2008

C.R.Narayana Rao Part I - C


Architects and engineers
Tidel,Coimbatore Preamble to Bills of Quantities

TIDEL PARK COIMBATORE LTD


( A JV OF TIDCO, ELCOT, TIDEL & STPI )
Notice for International Competitive Tender
BUILDING COMPLEX OF INFORMATION TECHNOLOGY PARK AT VILANKURICHI
(SEZ AREA), COIMBATORE

PREAMBLE TO THE BILL OF QUANTITIES - 1. GENERAL

1 The Preamble to the Bills of Quantities and Bill of Quantities must be read with the Drawings, Conditions of
Contract and the Specification and the tenderer shall be deemed to have examined the Drawings,
Specifications, Conditions of Contract and to have acquainted himself with the Works to be done and the
way in which they are to be carried out. This preamble to the Bills of Quantities shall form part of the
Contract.

2 Notwithstanding that the work has been sectionalised every part of it shall be deemed to be supplementary
to and complementary of every other part and shall be read with it or into it so far as it may be practicable to
do so.

3 The description of an item shall be deemed to include all preambles, headings, sub-headings and
references to other documents. The detailed description of work and materials, given in the Specification
are not necessarily repeated in the Bill of Quantities.

4 The rates for all items shall be quoted and priced in Indian Rupees only. Prices inserted in this BOQ are full
including cost of the work described and of the obligations setforth in the tender document. Rates should be
quoted both in Figures & words in Columns specified. In case of discrepency between the rates quoted in
figures and in words, lower of the two shall be considered. While quoting the rates for the items covered
under bill of materials, the tenderers should carefully read the Preamble under the respective heads also
and quote the rate accordingly.

5 Tenderers are instructed to quote "rate only" for all QRO items without fail and not to enter any amount in
the amount column. The rates quoted under QRO items is negotiable during the evaluation of the tender
and the rationalised rate only will be considered if there is a need to operate QRO items during execution.
Any percentage of discount / rebate offered by the tenderer during negotition is applicable on all the quoted
rates of the tendered items including "QRO" Items.

6 Each individual item in the Bill of Quantities is to be priced or if any items are not priced it is to be indicated
under which item or items the value of the work has been included. If the tenderer omits to quote an item
the cost of the work of such item shall be held to be spread over and included in the prices given for other
items and the tenderer should compulsorily execute that item for full quantity given in the bill of quantities at
free of cost, if the tenderer gets the work. However the successful tenderer shall quote the rates for such
items and get approved by the Employer. In such case such items are not required to be executed full / part
quantity, the successful tenderer shall pay appropriate amount for the quantity at the accepted rate to the
Employer. Tenderer should not mark items as "included" when the rate is asked for. Exactly similar items
in indivitual sections/sub-Head shall be priced similarly.

7 The rate entered against each item in the Schedule of Quantities shall be binding through out the Contract
and shall not be changed on account of any discrepancies or inaccuracies in the estimated quantities or any
other cause. All prices quoted shall be firm for the entire duration of the contract except cement &
reinforcement steel. The Contractor shall when contracting satisfy himself that the quantities are reasonably
correct within the scope of work. If there is any discrepancy, he should at once notify the Employer, so that
the matter can be examined, and if necessary altered before tenders close.

8 For the sake of convenience the Bill of Quantities is sectionalised to cover one structure or a group of
structures.

9 Unit Rates will be used as basis of payment for schedules and variation orders.

C.R.Narayana Rao
Architects & Engineers 1 1. General
Tidel,Coimbatore Preamble to Bills of Quantities

10 Cost of all materials, labour, equipment required, tools & plants required, conveyance, infrastructure facilities
required including heavy excavation machinery with supporting transport facility either own or leased, shall
be included in the quoted rates elsewhere. Contractor shall provide Steel pipe double Scaffolding to carry
out their works during execution of the project in good and operational condition within the Quoted Rates.

11 Rates and prices shall be quoted considering as SEZ Project set against items are to be the full inclusive
value of the finished work shown on the Drawings and/or described in the specification or which can
reasonably be inferred therefrom and are to cover the cost of marking layout of buildings for excavation,
fixing permanent grid points, establishing bench mark, provision of plant, labour, supervisions, materials,
erection, insurance cover for Third Party Liability and workmen compensation and other applicable
insurance cover , maintenance, overheads and profits and every incidental and contingent cost and charges
whatsoever. (in accordance with general conditions of contract Part - 1 of tender documents) and every
kind of temporary work executed or used in connection therewith and all the Sub Contractor's obligations
under the sub contract and all matters and things necessary for the proper completion and maintenance of
the Works.

The Tender will be finalized based on the competitive rates quoted for the total value of work including
materials, labour, services, etc. However break up details of materials, labour, services and also
taxes/duties to be provided as per the format enclosed for reference. The Owner shall not pay more than
the amount eligible to the contractor for SEZ Project.The SEZ benefits with respect to the duties and taxes
should be extended to the Owner. More over the contractor should furnish the total quantities of materials to
be used for the project with respect to source viz. local/imported to be clearly specified in the document for
indicative purpose. The contractor shall place the order for the materials/equipments after getting prior
approval from Owner.

The rates quoted in the price bid shall be firm and shall not be subject to variations in costs of any
or all inputs, such as but not limited to, materials, labour, exchange variations, labour conditions,
fluctuations in freights (including sea/road/railway) or any conditions whatsoever. No claim in
respect of any taxes or duties or levies as existing or future shall be entertained by the Owner. It
is expressly provided that the materials as above shall not include cement and reinforcement steel
for which price adjustment will be considered by the OWNER as per the terms and conditions
below :

The price adjustment clause will be applicable for cement and reinforcement steel items only. The
bench mark price for cement and reinforcement steel are fixed as given below, which include cost
of materials, all expenses, freight, insurance, Transit Insurance, handling charges and delivery at
site but excluding Excise Duty, Cess on Excise Duty and TNVAT.

Materials Benchmark price for SEZ Project

Cement (All Grades) Rs. 3,500/- per MT


Reinforcement Steel Fe500 (All Sizes) TMT Rs. 38,000/- per MT

No price adjustment will be given if the increase/decrease in cost of cement / reinforcement steel
varies upto 3% from the bench mark price.

If the price variation is more than 3% over the bench mark price, the excess cost of
cement/reinforcement steel over the bench mark price will be paid by OWNER based on the
invoice to be produced by the contractor. If the price of cement/reinforcement steel is decreased
more than 3%, the difference in cost over bench mark price will be deducted from the contract bill.

The price variation with respect to cement and reinforcement steel will be adjusted only in the final
bill after completion of work.
The price adjustment shall not be applicable for the extended period of completion, if the delay is
attributable to the contractor. The price adjustment clause will not be applicable if the delay in achieving
milestones is attributable to the contractor.

12 Any change in the quoted rates due to any variation in price(ie. Increase / decrease In Price) except for
cement and reinforcement steel, shall not be considered and will be to the contractor's account.

C.R.Narayana Rao
Architects & Engineers 2 1. General
Tidel,Coimbatore Preamble to Bills of Quantities

13 The specification is intended to cover the supply of material including providing minor civil works such as
Establishing Permanent Grid points and permanent Bench mark on the neatly plastered brick pillar, and the
execution of all works necessary to complete the entire scope of work. Should there be any details of
construction or materials which have not been referred to in the Specification or in the Bill of Quantities and
Drawings, but the necessity for which may reasonably be implied or inferred therefrom or which are usual or
essential to the completion of all works in all trades, the same shall be deemed to be included in the rates
and prices named by the tenderer in the Bill of Quantities. If there is inconsistency between the Bill of
Quantities, Specification and Drawings and in case of conflict among different sections/heads, precedence
shall be given in the following order of descending priority.

a. Bills of Quantities & Preamble to the Bills of quantities.


b. Technical Specification.
c. Tender Drawings.
d. IS code (Indian Standard) / other equivalent codes

14 Providing all the water required for the Construction work or by any means including testing the water
proofing works or by any means, by arranging the water from the approved source including obtaining an
acceptable quality water from outside by tanker for all purpose within the quoted rates.

15 Providing power required for the construction work or by any means with in the premises including making
his own arrangements to obtain temporary power connection and maintain at his own expense an efficient
service of electric light and power during the contract period. Any shortfall in quantum of electric power from
electric company's supply shall be made up by necessary captive generator at site including all charges
connected with installation, running and maintenance, necessary statutory approvals etc. within the quoted
rates.

16 Providing water and power required for testing and commissioning of various items specified in the Bill of
Quantities and Technical Specifications within the quoted rates.

17 Constructing and providing water proof water storage tank to the required capacity for storing the water for
construction purposes during the construction period including maintaining the water during this period.
Construction and location of the tank shall be in accordance with the approved drawing and at no extra cost.
The same shall be dismantled, removed, cleaned and disposed of at authorised area out of site premises at
no extra cost.

18 Constructing and providing temperory site office for Employer/Architect to the requirement specified in the
conditions of contract for use during the construction period including all amenities and Facilities like
Necessary electrical facility ,Local telephone, Photocopier Facility, Internet connection and Fax connection
within the quoted rates. Telephone charges and Power and any other charges, Maintainence of all Facilities
and Maintainence shall also borne by the contractor. At the time of successful handing over of the project to
the Employer or at any time earlier, as directed by the Employer, the entire site office structure shall be
dismantled and removing the accommodation including debris and restore the site at no extra cost.

19 Providing and forming all temporary roads / Pathways, cross overs, foot path, tracks, hard standings,
Temporary ramp to approach the excavated level etc. within the site and shall provide temporary foot path
outside the boundaries if required to protect the public entering into the construction area at no extra cost.

20 Providing and establishing required plants, machineries, equipments, scaffolding, staging, guard rails,
temporary stairs, temporary access to the various places of the premises during execution stage, including
maintenance of all the machineries, tools and plants, Heavy excavation machineries with supporting
transport facility etc., required consumables for such equipments till the completion of the work for proper
execution of work and providing well maintained temporary toilets for Labourers as required ( Minimum - 3
Nos at desired location by Employer/Architect) during execution till completion of the entire work within the
quoted rates.

21 Providing and maintaining Field Laboratory in a satisfactory manner till the completion of work to ensure site
control on quality of materials and the works and shall strictly comply with provision of indian/ International
Standards at no extra cost. All other regular tests including requisite materials shall be carried out as
directed either at approved laboratory or at site at no extra cost.

22 Providing drains and establishing means and disposal of storm water from the site during construction
period.

C.R.Narayana Rao
Architects & Engineers 3 1. General
Tidel,Coimbatore Preamble to Bills of Quantities

23 Providing barricade and enclosure around the premises of the site by using the aluminium sheets or GI
corrugated sheets duly painted neatly with required supporting arrangements with verticals, horizontals and
bracing including maintaining the barricade and enclosure till the entire completion of the work at no extra
cost. Barricades and hazardous areas adjacent to but not located in normal routes of travel shall be marked
by red flasher lanterns at nights. The same shall be dismantled, removed, cleaned and disposed of out of
site premises at no extra cost.

24 Providing all safety measures including barricade and enclosure around the excavated trench/area in the
site during excavation by using the R.C.C post at 3 m Intervals to a height of 1.5 m from the existing G.L
with suitable depth of foundation ( Minimum 0.60 M from Existing G.L ) and providing Polyster insulated
chain link fencing and fixing the chain link using M.S.Flat 30 x 6mm with bolting arrangements including
painting the post neatly. R.C.C post shall be placed on PCC 1:2:4 to a required depth to hold the post
including maintaining the barricade and enclosure till the entire completion of the work at no extra cost.
Barricades and hazardous areas adjacent to but not located in normal routes of travel shall be marked by
red flasher lanterns at nights. The same shall be dismantled and removed after the completion of work with
in the quoted rates.

25 Providing and establishing disposal of any water from the site due to rains and de-watering at the site during
excavation at no extra cost.The arrangement for suitable de-watering system shall be the responsibility of
the tenderer, so that the excavated area and site is kept sufficiently dry and fit for works during the contract
period. Arrangement for any additional means of de-watering as may be required depending on the
exigencies shall be the responsibility of the Contractor without any claim to extra. Similarly retention of the
excavated sides and stability of the slopes and prevention of land slides shall be the responsibility of the
Contractor within the quoted rates. All such precautionary and safety measures for earthwork excavation
and dewatering shall not hamper the construction schedule at any time within the quoted rates.

26 All rules and regulations of Labour Department, Contract Labour Laws, Provident Fund and ESI and
connected laws, and all other laws of the land are to be complied with by the tenderer within the quoted
rates.

27 Providing security arrangements to guard the site and premises at all times to maintain strict control on the
movement of material and labour till the completion of the work within the quoted rates.

28 Setting out the works at site shall be the entire responsibility of the Contractor for excavation including
maintaining the premises throughout the contract period, proper permanent grid line points and datum
bench mark within the quoted rates.

29 Maintain the site and surroundings in neat and orderly manner, free of accumulation of debris, haphazard
stacking of materials, unhygienic and unsafe environment, cleaning the site at all levels, removal of
unwanted materials on day-to-day basis during the contract period at no extra cost.

30 The estimated quantities given in the bill of quantities shall be regarded as approximate only and shall not
be deemed to gauge the extent or description of the works, or to limit the effect and meaning of any of the
provisions of the contract documents.

31 The quantities in the Bill of quantities approximately indicate the total extent of work but may vary to any
extent and may even be omitted thus altering the aggregate value of the contract. A Schedule of Probable
Quantities in respect of each trade of work is covered in Part II. Individual items in the Schedule of
Probable Quantities is liable to alteration without any pre-specified limit to extent of such variations by way of
omissions, deductions or additions at the discretion of the Architect/Owner's Engineer. Each Bid should
contain not only the rates but also the value of each item of work entered in the amount column and all the
items should be totaled in order to show the aggregate value of the entire Bid. The value of each item
worked out shall be rounded off to a nearest Rupee ignoring paise below fifty.

32 Owner/ Architect reserves the right to itself the right of altering the drawings and nature of work by adding to
or omitting any items of work or having portions of the same carried out without prejudice to this contract.
There shall be no limit on the scope and extent the changes that can be ordered by the Owner and the
contractor shall not be entitled to any compensation or claim due to such change(s) / order(s) by the Owner.
The contractor will only be paid for the actual quantity of works done payable at the agreed unit rates.

C.R.Narayana Rao
Architects & Engineers 4 1. General
Tidel,Coimbatore Preamble to Bills of Quantities

33 Any permission required for establishing the site office including executing the work to be obtained from the
statutory Authority shall be responsibility of the tenderer within the Quoted rates.

34 No Land will be provided by the company to the contractor for constructing any structure, his labour,
workman and supervisory camps, un-authorised hutments, canteen or teashops at site or within the
premises. Contractor shall make his own arrangements for the same outside the Premies / boundary. These
if any, shall be with the knowledge of and prior approval of the Owner/Architect.

35 The samples of materials for various finishing items such as Granite, Marble, Ceramic Tiles, Sealent, Glass
for various applications, Aluminium members etc. shall be produced by the tenderer as & when required by
the Owner/Architect during the evaluation of bids for scrutiny and approval. All samples required by the
specification for the approval of the Owner / Architect shall provide at any stage till the completion of work
and provide safe storage including recess for display, reference and inspection of approved sample at no
extra cost.

36 Successful tenderer shall provide the samples of materials for various finishing items such as Granite,
Marble, Vitrified Ceramic Tiles, Ceramic tile, Sealent, Glass for various applications, Aluminium members,
wooden & steel door, Hardwares & Fixtures, any other materials specified in the Bills of materials
necessiated approval by the Owner/Architect. All samples required by the specification for the approval of
the Owner / Architect shall provide at any stage during execution till the completion of work and provide safe
storage including recess for display, reference and inspection of approved sample at no extra cost.

37 Arranging, taking and providing colour photographs, video films during construction period at various stages
from different locations to show the progress of work at every week including on special occasions and
novel features of the work as desired through out the contract period.

The photographs shall be of acceptable quality and they shall be taken by a professionally competent
commercial photographer with camera having the facility to record the date of photographs taken in the
prints and negative. The Contractor shall supply five colour prints of each of the photographs taken to the
standard maximum size mounted in albums of acceptable quality. Also the negative in 35mm size shall be
supplied for each photograph. Each photograph in the album shall be suitably captioned.

Video films shall be taken by a professionally competent commercial video cameraman and edited with
Digital Photographs( Both Soft & Hard Copies ) to be taken and submitted as a part of Monthly Report - to
be included date and time. The edited video cassettes shall contain narration of the activities in Engilish by
a competent narrator. The edition of the video film and the script for narration shall be as approved. The
video cassettes shall be of acceptable quality and the film shall be capable of producing colour
pictures.Videocasettes shall be converted in to CD form as & when required by Owner/Architect and
required no. of copies shall be supplied. The entire expenses on this account shall be borne by the
Contractor and he is not eligible for any payment on this account.

38 The abbreviations used in the Specification and Bill of Quantities shall be read as follows :
IS - Indian Standard
A.S.T.M - American Society for Testing and Materials
A.W.S. - American Welding Society
MM & mm - Millimetre /s
CM & cm - centimetre /s
L.M.(lm) - Linear metre /s
RM (rm) / RMT (rmt) - Running metre /s
KG (kg) - Kilograme /s
Tonne/t/MT - Metric ton/s (1000 Kilogrammes)
Dia. - Diameter
Wt .- Weight
Sq.m. - Square metre
Cum - Cubic metre
No. - Number
Qty. - Quantity
L.S - Lumpsum.
P.S. - Provisional sum

C.R.Narayana Rao
Architects & Engineers 5 1. General
Tidel,Coimbatore Preamble to Bills of Quantities

Q.R.O - Quote rate only.


Drg.No. - Drawing number
P.C.C. - Plain Cement Concrete
R.C.C. - Reinforced cement concrete
H.S.D - High Yield strength Deformed bars.
M.S. - Mildsteel
C.R.S. - Corrosion resistence steel.
C.T.D. - Cold Twisted Deformed steel.
TMT - Thermo Mechanically Treated Bars

39 A copy of soil report is enclosed in Part - I for the reference to the tenderer as to identify the nature of soil,
but the enclosed soil report is only indicative. The tenderer is expected to inspect the site to investigate the
following items before quoting the rates in the tender and the entire responsibility for amenities & services
therefore shall be sole responsibility of the tenderer.

a. Nature and type of soil proposed for excavation and safety of excavation..
b. Availability of Power for execution.
c. Availability of Water for execution.
d. Means of Disposal of storm water/bailingout water from the site.
e. Means of Disposal of water due to De-watering at the site.
f. Nature and type of protection required for Neighbouring property to ensure full safety during Construction
activities in Progress.
g.Place for disposal of serviciable / unserviciable materials obtained during Construction activities in
Progress.

40 Housekeeping for the entire site on a regular basis by deputing adequate dedicated resources (To be
agreed with PMC) at no extra cost.
41 Area lighting and Task lighting in accordance with site safety rules.

42 Fall protection for voids, cutouts, shafts & construction openings as per safety guidelines to be factored.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 6 1. General
Tidel, Coimbatore Preamble to Bills of Quantities

PREAMBLE TO THE BILL OF QUANTITIES - 2. EXCAVATION & FILLING WORKS

Unless otherwise specified rates quoted for all Excavation and Filling works shall include the following :

1 Cost of all materials, labour, equipment / tools & plants required, conveyance, infrastructure facilities
required etc.

2 Site clearance such as clearing shrubs and growth, roots and small trees brush wood, wild growth etc and
local humps, debris.

3 Work shall be at all levels, heights & elevation and location. Setting out the work to profile and making
the site suitable for marking layout of building by establishing the suitable Survey Equipments.

4 Providing and fixing of permanent grid points with Galvanised M.S. angle iron posts embedded in cement
concrete 1:1.5:3 and placed sufficiently away from building line, and establishing bench mark as well.

5 Excavation in any kind of soil including filled up soils, soft & hard disintegrated rock , hard murrom with
boulders and hard rock or as specified in the Bill of Quantities.

6 Excavation in hard rock shall be either by mechanical means like Air-compressed rock chissler/breaker,
Hydraulic hammer or manual means other than blasting (which is prohibited) or by using chemical
compound of `Accunix' of Associated Cement Company or equivalent approved make and as per
manufacturers specification, if required.

7 Excavation in any kind of soils including soft & hard dis-integrated rock shall be carried out as per site soil
condition and safety of excavation and as per the approved excavation plan. Methodology for Excavation
and De-Watering shall be got approved from the employer prior to commencement of work.
Employer/Architect's decision in this regard is final and binding on the Contractor.

8 Staging, timbering, strutting and de-watering (baling out water either sub soil, rain water or surface) and
keeping trenches and excavations dry at any stage of work. Rate shall also include de-watering, so as to
keep the excavated area dry during the progress of foundation works and till the measurements are
recorded and check measured. Necessary provision to be made to drain the water through peripheral
drain and connecting the same to the main drain. Any extra width of excavation as per site soil condition
and safety of excavation in the pits and trenches, mass excavation for working space or for any kind of
works including waterproofing treatment works required by the Contractor, shall be carried out as per site
condition and safety of excavation, within the quoted rates. Providing shoring & strutting / sand bag lining
for protecting the sides of excavation as required. Filling the extra width of excavated area by the
contractor for such purposes with approved fill material and consolidating the same to get the required
proctor density shall be within the quoted rates.

9 Cutting through old foundations of all description, hard deposits which may be encountered during the
course of excavation.

10 Dismantling, removing,stacking and disposing the same away from the site of existing water pipes and/or
soil pipes within the excavation portion as directed..

11 Providing shoring and strutting for protecting the sides of foundations / trenches, wherever required.

C.R.Narayana Rao
Architects & Engineers 7 2. Excavation & Filling
Tidel, Coimbatore Preamble to Bills of Quantities

12 Getting out and throwing spoil clear off area being excavated or depositing clear of edge of foundation to
avoid fall in.

13 Trimming all sides to plumb or otherwise as instructed at site, levelling all bottoms, clearing out all loose
earth etc.

14 The selected fill material shall be approved by the Employer / Architect before the same is used for
filling.The fill material shall be as specified. Black cotton, clayey or silty soil shall not be used. Soils
having laboratory density of less than 1.44 gm/cc may not be used for filling.

15 Filling in foundations and in plinth in layers not exceeding 150 mm, watering, consolidation, dressing etc.
complete and include for all lifts and leads, transport from stacks, rehandling etc.

16 Filled earth shall be watered and compacted by power roller or any other approved mechanical means or
adequate capacity to achieve the required minimum proctor density of 95% to 98 %.

17 Top layer of filling shall be brought to the specified line, levels grade and to the required proctor density
and as directed.

18 Disposing of excavated earth as directed and dressing to proper level and grade as required or by
transporting out of site to dumping ground legally approved by local authorities at no extra cost.

19 Taking necessary precautions to prevent spillage of disposable earth during transport.

20 Removal of excavated earth out of the premises shall be done simultaneously during the excavation stage
itself due to paucity of working space.

21 Supplying of utility services as directed and providing guard lights and Guard railing for trenches wherever
required.

22 Wherever the double handling of excavated earth is required, the place of deposit should be decided in
the first instance and to be deposited as directed.

23 Excavation will be measured on the basis of the horizontal area of open mass excavation at the base for
raft slab or any other structures to be built. The actual depth of excavation will be arrived at as the
difference between the spot levels taken at existing ground level prior to excavation at a spacing of 3m
intervals in both directions and the final bottom level of founding level as per drawings.Quoted rate shall
include cost of excavation of working space as required, slopes and berms as per site soil
condition/nature of the site soil and safety of excavation.Rate shall also include for refilling the such
excavation of working space with approved filling Material including consolidating to the required proctor
density.Quoted rate shall be deemed to have considered the above stipulation.

24 Excess excavation if any, in horizontal direction shall be filled with concrete of Grade 1:2:4, on prior
approval by the Employer/Architect for making up the excavated area to the required level at no extra
cost. Any other means of filling shall not be allowed.

25 Cement for all works shall be High strength ordinary portland cement Grade 43 and 53 grade shall be
used.

26 Tests on materials shall conform to IS Specification and the test shall be carried out as directed either at
site Laboratory or at any approved test laboratory.

C.R.Narayana Rao
Architects & Engineers 8 2. Excavation & Filling
Tidel, Coimbatore Preamble to Bills of Quantities

27 The method statement shall include all safety features and protection to workmen, thitrd party as well as
property and services nearby. Methods of shoring and struting should be fully detailed in the method
statement.Removal of excavated material from excavated area,method of handling,method of storage(
including double handling if necassary) as well as disposal shall be explained fully. Where controlled
blasting resircted to,the contractor should ensure that all necassary statutory approvals are obtained in
advance and kept in current and all necassary insurance and other covers shall be taken and kept valid in
the case of sub-contracting this job,such cover shall include sub-contractor's workman also.Where
controlled blasting is resorted to, contractor should take all necasry precaution for ensuring safety of life
end property in the visinity.Suitable barigading,warning systems, sand cushing,heavy duty protection in
the blast area shall be under contractors responsibility. The contractor shall note that surrounding
buildings are fully occupied and are in operation and as such, all possible special preacautions shall be tak
into account in view of restricted area availabe for contruction.No extra claim for payment are
additional time will be accepted on account of failure to take into account the above factors prior to
quoting.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 9 2. Excavation & Filling
Tidel,Coimbatore Preamble to Bills of Quantities

PREAMBLE TO THE BILL OF QUANTITIES - 3. ANTI - TERMITE TREATMENT WORKS.

Unless otherwise specified, the rates quoted for Anti-Termite treatment shall include the following :

1 Cost of all materials, labour, equipment / tools & plants required, conveyance, infrastructure facilities
required etc.

2 Work shall be at all levels, heights & elevation and location.

3 All equipments employed, tools, tackles etc.

4 Treatment to all areas required to be treated at any depth & level in the sequence including trenches,
pits and tunnels etc.

5 Making holes, providing nozzles and injecting etc.

6 Treatment should be carried out by an approved specialised pest control agency on prior approval.

7 Treatment should be carried out generally in accordence with the technical specification and
confirming to IS 6313.

8 The chemical to be used as insecticides for the treatment shall be CHLOROPYRIPHOS 20% EC
and the application shall be Dilute 1 part of chemical 20/50 EC with 19/49 parts of water to get 1%
Emulsion and as per manufacture's specification.

9 Connected civil work such as cut-open the surface for treatment, insertions like nozzles at require
places. Protecting the treated surface and other works in progress and redoing in case of any
damage.

10 The description and specification for treatment contained in the Bill of Quantities is indicative only
and is meant to set out a general outline of the Proprietary system as commonly understood. The
eventual requirement is performance oriented to achieve total termite proof expected from the
system that is adopted. Since the systems, both in materials and methodology of application, are
proprietary, the onus of examining the drawings, BOQ, specifications and site conditions lies on the
Contractor. The prices quoted shall be comprehensive and appropriate and shall include all the
applicable items envisaged in the system, whether or not they have specifically described in the
documents / information supplied.

11 Anti-termite treatment shall be guaranteed for a period of 10 (Ten) years in an approved proforma
acceptable to the Employer on a stamp paper.

12 Material Safety Data Sheet to be submitted and approved prior to use at site.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 10 3. Anti-termite Treatment works
Tidel,Coimbatore Preamble to Bills of Quantities

PREAMBLE TO THE BILL OF QUANTITIES - 4. PLAIN & REINFORCED CEMENT CONCRETE WORKS.

Unless otherwise specified, the rates quoted for Concrete items shall include the following:

1 Cost of all materials, labour, equipment / tools & plants required, conveyance, infrastructure facilities
required etc.

2 Work shall be at all levels, heights & elevation and location.

3 Cost of suitable form work and bracing according to the floor height specified in the drawing, moulds,
centering and shuttering, single / double height scaffolding, GI pipe as directed at site. Dimension of
form work will be within the tolerance as specified in IS 456 and shuttering should be water tight.
Shuttering materials shall be steel, timber or plywood as directed.

4 Exclude cost of reinforcement steel, structural steel and any inserts like bolts, plates, sleeves, pipes etc,
but include building in and placing in position any inserts supplied

5 Form work ( which shall be measured and paid seperately under relavent item ) include splayed edges,
notching, allowances for overlaps and passing at angles, batterns, strutting, bolting, wedging, casing,
rocking, centering, boxing, shuttering, propping strut braces etc., removal thereof and dressing the
shuttering with oil to prevent, cement sticking to shutter faces.Form work shall be either straight, curved,
plain or tapered and also with provision for specified slopes, if directed. Wind tie bolts for wall
shuttering.

6 Form work for fair faced concrete items will be of resin bonded plywood of approved make in any size
required for the purpose under such item, fixed on suitable frame work including MS clear separators, if
so specified.

7 Bitumen/Ocean kraft papers shall, where directed be laid at all places of flooring before laying levelling
course for flooring.

8 Adequate protection to edges and corners of Plain & Reinforced Cement Concrete works from damage
during construction.

9 Weigh batching, machine mixing, transporting, pumping, placing and consolidation using vibrators of
approved type as directed.

10 Keeping the work well watered for 10 days for plain cement concrete works and 21 days for Reinforced
cement concrete works after casting and it shall confirm to IS Specification.Providing water tight casting
platform, curing yard, form work, steel or plywood mould for preparation of precast slabs & Jolly.

11 Roughening and hacking the concrete surfaces wherever required after removal of centering or
shuttering.

12 Forming key and construction joints, providing cement slurry work and cleaning at any stage of work,
sand papering of existing reinforcement bars of column and dowels from pile caps etc. as directed
before taking up fresh work.

13 All projections, toothings, ornamental work, finishing to shape as per drawing and as directed.

14 Making all drips, grooves, moulds, curved surfaces etc as directed..

15 Coarse graded sand shall be used for all concrete works.

16 Machine crushed coarse graded aggregate shall be hard broken blue granite of sizes specified.

17 Cement for all concrete works shall only be High strength ordinary portland cement Grade-43.

C.R.Narayana Rao
Architects & Engineers 11 4. Concrete works
Tidel,Coimbatore Preamble to Bills of Quantities

18 Cement Grade 53 / Grade 43 shall be used only for the items so specified within the Quoted Rates.
Cement - Ordinary Portland Cement 53 grade conforming to IS: 12269 and Ordinary Portland Cement
43 grade conforming to IS: 8112 , shall be used for all Reinforced Cement Concrete works and Portland
Pozzalona Cement of 33 Grade conforming to IS: 269 for Plain Cement Concrete works, masonry,
plastering and any such other works. In general fly ash based cement shall not be used for RCC works.

Water used for concrete shall confirm to the requirement of IS: 456.

19 Minimum cement content for specified design mix shall be in accordance with specification. Minimum
cement content will be the same as specified in the Technical specification Irrespective of grade of
cement used.

20 Designing the concrete mix and batching as per specifications, wherever design mix is specified and
approved, if so directed.

21 Use of weighbatch equipment for design mix concrete and machine mixed and mechanically vibrated on
placement in position as directed.

22 Providing Ready Mix concrete from approved source conforming to Specification & standards.

23 Adding of admixture to increase the workability and consistancy in the concrete as slump retarder as per
manufacturers specification wherever required and applying admixture / bonding agent to increase the
bonding between the old & New concrete and at Construction joints as per manufacturers specification
wherever required, on prior approval at no extra cost.

24 Limiting the temperature of concrete to the required level as directed, wherever required under such
item and if so specified on prior approval.

25 Providing sunk floors, pockets, cutouts, holes and larger size openings for security doors as also
concreting them after the doors are held in position, including grouting of hold fasts, under the
supervision and instructions of security contractors.

26 Embedding electrical conduits, junction boxes, fan hooks, cutout boxes and other inserts, sleeves hold
fasts, pipes etc.

27 Necessary spacer blocks made out of plain cement concrete 1:2:4 or cement mortar 1: 4 to be provided
to prevent the displacement of reinforcement and also to maintain the required dimension, if required..

28 No finishing item is to be considered in quoting the rates for plain cement concrete works & Reinforced
cement concrete works, if so specified.

30 Taking test cubes for all concrete items and testing them as specified in IS 456 at the site laboratory to
be set up with proper equipment etc. and other regular test shall be carried out as directed either at site
Laboratory or at any approved test laboratory.

31 Tenderer shall ensure that they have adequate quantity of shuttering and suitable propping materials
according to the floor height specified in the drawing to keep up the required Concreting cycle per floor
as set out in the Tender Documents, Drawings and tentative Bar chart enclosed. They shall also ensure
that the de-shuttering sequence with proper propping, taking into account the Construction Loading of
the upper slabs, as set out in the Tender Drawings, is also kept up.Scheme to maintain the props shall
ensure that main supports are not disturbed.Reproping by means of removal and reintrodusing of props
is not allowed.
De-shuttering and re-propping scheme shall be such that any undue loading on the structure is avoided
at all times. On award of contract, the scheme must be submitted by the contractor along with
submission of the CPM / PERT to the Architect / Owners Engineer for necessary approval.

C.R.Narayana Rao
Architects & Engineers 12 4. Concrete works
Tidel,Coimbatore Preamble to Bills of Quantities

No extra charge will be allowed to the Contractor for all above such works

32 Any tenderer who proposes any innovative or special propping according to the floor height specified in
the drawing, shuttering and de-shuttering methodology maintaining the required Concreting cycle per
floor shall furnish comprehensive and complete details of the same along with tender submission.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 13 4. Concrete works
Tidel, Coimbatore Preamble to Bills of Quantities

PREAMBLE TO THE BILL OF QUANTITIES : 5. MASONRY WORKS

Unless otherwise specified, the rates quoted for items under masonry work shall include the following :

1 Cost of all materials, labour, equipment / tools & plants required, conveyance, infrastructure facilities
required etc..

2 Work at any depth below ground level or any height above ground level and at all levels, heights &
elevation and location.

3 All double height scaffolding, ladders, platforms, staging and plant required in the execution of work to
any height and depth.

4 Best quality well chamber burnt moulded bricks conforming to IS 1077 and with minimum compressive
strength of 50 Kg/Sqcm only shall be used on the masonary work.

5 Brick work shall conform to IS 2212.

6 Hacking and roughening of concrete or other surface in contact with masonry for proper bondage.

7 All work in narrow widths, curved or straight as per drawing and as directed.

8 Provision for drip moulds, projections and architectural mouldings etc. and excludes RCC mullions,
panels and stiffeners to be provided in Masonry work.

9 Embedding in Galvanised M.S. holdfasts in Plain cement concrete 1:1.5:3 blocks, coach screws,
anchor fasteners and such other inserts, including chasing, grouting,curing etc..

10 Fix in position electrical conduits, cut-outs, and with chasing wherever necessary.

11 Raking out joints to specified depth either for plastering or pointing.

12 Levelling up and preparing top of masonry for damp proof course.

13 Keeping the work well wetted for two weeks.

14 Providing key stones to any thickness of walls as required in block masonry.

15 Tests on bricks/block/ or any other masonry items as directed, conforming to IS Specification shall be
carried out as directed either at site Laboratory or at any approved test laboratory.

16 Providing water tight casting platform, curing yard, form work, steel or plywood mould for preparation of
precast blocks.

17 Conveyance of all materials to the required places.

C.R.Narayana Rao
Architects & Engineers 14 5. Masonry works
Tidel, Coimbatore Preamble to Bills of Quantities

18 Solid / Hollow block to any size shall conform to IS : 2185 and confirming to :
A. Solid Block :
1. Size of Block :
400x200 mm - 100 mm thick
400x200 mm - 200 mm thick
400x200 mm - 300 mm thick
2.Dimension tolerance:
Length of the units - Not morethan (+) or (-) 5 mm.
Height & width of the units - Not morethan (+) or (-) 3 mm.
3.Percentage of solids - Not less than 75%
4.Weight of a block in Kg.
400x200 mm - 100 mm thick - Not less than 14.4 Kg.
400x200 mm - 200 mm thick - Not less than 28.8 Kg.
400x200 mm - 300 mm thick - Not less than 43.2 Kg.
5.Yard dry density in Kg/Cum - not less than 1800 Kg/Cum.
6. Water Absorption - 5 to 6 %
7. Compressive Strength - not less than 5 N/Sq.mm conforming to BOQ Specification.
8. Thermal resistance - .38 to .33 Sq.mm
9. Estimated sound - 46 to 58 Db.

B. Hollow Blocks :
1. Size of Block :
400x200 mm - 100 mm thick
400x200 mm - 200 mm thick
400x200 mm - 300 mm thick
2.Dimension tolerance
Length of the units - Not morethan (+) or (-) 5 mm.
Height & width of the units - Not morethan (+) or (-) 3 mm.
3.Percentage of solids - 55%
4.Weight of a block in Kg.
400x200 mm - 100 mm thick - Not less than 12 Kg.
400x200 mm - 200 mm thick - Not less than 24 Kg.
400x200 mm - 300 mm thick - Not less than 36 Kg.
5.Yard dry density in Kg/Cum - Not less than 1500 Kg/Cum.
6. Water Absorption - 5 to 6 %
7. Compressive Strength - not less than 5.5 N/Sq.mm conforming to BOQ Specification.
Compressive Strength - not less than 3.5 N/Sq.mm conforming to BOQ Specification.
8. Thermal resistance - .38 to .33 Sq.mm
9. Estimated sound - 46 to 58 Db.

19 Providing reinforced cement concrete binder of specified grade - 80mm thick with reinforcement steel of
Fe 500 - 8 mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm dia for stirrups at 200mm centres for Half
brick masonry wall - 115mm thick at 1000mm intervals under the respective BOQ item.

C.R.Narayana Rao
Architects & Engineers 15 5. Masonry works
Tidel, Coimbatore Preamble to Bills of Quantities

20 Providing reinforced cement concrete binder of specified grade - 80mm thick with reinforcement steel of
Fe 500 grade - 8 mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm dia for stirrups at 200mm centres for
Solid / Hollow block masonry wall - 100 /150 mm thick under the respective BOQ item.

21 At the junction of Hollow block or brick masonry a bearing block of concrete or intervening brick in
mortar courses shall have to be introduced wherever required including nominal reinforcement.

22 Cement used for all Masonry works shall be Portland Pozzalona Cement of Grade 33 conforming to
IS 269.

23 Coarse graded sand shall be used for mortars in all masonry works.

24 Machine crushed coarse graded aggregate shall be hard broken blue granite of sizes specified only to
be used for concrete works.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 16 5. Masonry works
Tidel, Coimbatore Preamble to Bills of Quantities

PREAMBLE TO THE BILL OF QUANTITIES : 6. REINFORCED STEEL& IRON WORKS

Unless otherwise specified, the rates quoted for items under Reinforced steel Iron works shall include the
following:

1 Cost of all materials, labour, equipment / tools & plants required, conveyance, infrastructure facilities
required etc..

2 Work at any depth below ground level or any height above ground level and at all levels, heights &
elevation and location.

3 All reinforcement steel shall be the Grade of Fe 500 Thermo Mechanically Treated conforming to IS
1786 and shall be used as specified elsewhere in the bills of materials.

4 Cutting and waste, straightening, bending, hoisting, fixing, supporting in position using precast plain
cement concrete 1:2:4 cover blocks / PVC cover blocks as directed and tying with approved binding
wire made out of no 18 gauge G.I. annealed and welding with electrodes for lapping the rods wherever
required. All welding with electrodes shall be in accordance with IS.

5 Unless otherwise noted in the bills of Quantities, method of measurements shall be generally in
accordence with IS 1200. Reinforcement shall be measured only in lengths of bars as actually placed in
position on standard weight basis, no allowance being made in the weight for rolling margin. Authorised
laps and splices ,Chairs of any shape & profile, Spacer bar of any shape & profile, cover block,
wastage and binding wire will not be measured and shall be included in the quoted rates.

6 All materials supplied shall be free from manufacturing defects and defective workmanship and
guaranteed. Any defects noticed shall be made good at no extra cost.

7 Steel doors and Steel casement windows and ventilators, including all its fittings, shall be manufactured
to conform to IS 1038 and IS 7452.

8 Appropriate sections having the specified weight characteristics only shall be used for the frames and
shutters.

9 Shutters of all Doors, windows and ventilators shall be as per drawing and as approved.

10 Projecting type stainless steel hinges / pivot hinges must be provided for all side hung shutters.

11 Providing and fixing all joinery hardware fittings like floor spring, mortice lock, cylindrical lock, door
closer, handle, hinges of approved make and ISI mark.

12 All the members shall be finished with one coat of Anti- corrosive primer/ Zinc chromate / Zinc
phosphate primer after through cleaning of the surface to remove rust/scale, oil etc., in accordance with
relavant I.S standards and specifications. Extra coat of painting shall be given to obtain uniform and
good finish and extra putty shall be applied to ensure uniform and smooth finish, if directed.

13 Fittings supplied shall be sturdy and samples of all fittings shall be got approved before fabrication.

C.R.Narayana Rao
Architects & Engineers 17 6. Reinforced steel & Iron works
Tidel, Coimbatore Preamble to Bills of Quantities

14 Workmanship and finish of the Doors, windows, ventilators and fittings should be as per approved
standards and confirming to IS specification.

15 All hardware fittings such as Pegstays with screws, Standard Handles, Spring, catches, lugs with
suitable screws, Glazing clips, Transomes, Mullions, Coupling bars, Weathering bars, where necessary
Cast aluminium alloy or pressed steel stove enameled wrinkle finish.

16 Supply of hardware fittings like coupling, mullions, and additional fixing like clamps, bolts, nuts,
washers etc., for continuous fastening of windows / structural steel members.

17 Fabrication of Doors, windows and ventilators shall be in all respects including all associated costs upto
delivery at site.

18 Erection of fabricated Doors, windows and ventilators shall be placed in position including lifting,
jointing and painting as specified in the bills of quantities.

19 All welding with electrodes used for fabrication shall be in accordence with IS specification and as
approved.

20 Tests on materials shall conform to IS Specification and the test shall be carried out as directed either
at site Laboratory or at any approved test laboratory.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 18 6. Reinforced steel & Iron works
Tidel, Coimbatore Preamble to Bills of Quantities

PREAMBLE TO THE BILL OF QUANTITIES : 7. STRUCTURAL STEEL WORK AND SHEETING.

Unless otherwise specified, the rates quoted for items under Structural steel works and sheeting work shall
include the following:

1 Cost of all materials, labour, equipment / tools & plants required, conveyance, infrastructure facilities
required etc..

2 Work at any depth below ground level or any height above ground level and at all levels, heights &
elevation and location.

3 Weight of steel will be the measured on weight basis in accordance with IS 1200, but no wastage will
be considered.

4 No deduction will be made for bolt holes, notches, chamfers etc and no addition will be made for
welding.

5 Weights of bolts, nuts, washers etc. should be included in the main steel work and as such no
separate payment for these will be allowed.

6 Fabrication of the structural steel items shall be completed in all respects including all associated
costs upto delivery at site.

7 Erection of fabricated items shall be carried out including lifting, placing in position, jointing and
painting as specified in the Bills of materials.

8 All welding with electrodes shall be in accordence with IS specification and as approved.

9 Anti-corrosive treatment to structural steel with specialised painting for all steel works should be
carried out including preparation of surface confirming to IS specifications, if specified in the bills of
materials.

10 Provide and use cranes of different capacities for material handling and leading, separate mobile
crawler / wheel mounted crane with telescopic boom etc., as appropriate for erection of roof steel
works at all levels and various locations.

11 Provide use of suitable type of cranes, since as several works will be in progress simultaneously like
mass exacavation for pits and trenches and close and usual access may not be available for steel
work erection.

12 Sufficient number of cranes for material handling, feeding and larger capacity cranes for erection at
all levels and various locations should be mobilized.

13 provide for using sufficient cranes with telescope boom for carrying on truss erection work in a speedy
manner, with sufficient telescope reach boom and carrying capacity as erection may have to be done
from a long distance from actual spot. Due to progress of other works such as excavation or
concreting of pits and trenches at the same time more than one crane may be required for safety
consideration.

C.R.Narayana Rao
Architects & Engineers 19 7. Structural Steel
Tidel, Coimbatore Preamble to Bills of Quantities

14 All materials supplied shall be free from manufacturing defects and defective workmanship and
guaranteed. Any defects noticed shall be made good,at no extra cost

15 Workmanship and finish of the fabricated items should be as per approved standards and confirming
to IS specification.

16 Painting shall be provided with two or more coats of approved brand as specified in the Bills of
materials.

17 Extra coat of painting shall be given to obtain uniform and good finish and extra putty shall be applied
to ensure uniform and smooth finish, if directed.

18 Performance guarantee for anti-corrosive treatment with specialised painting for 5 (Five) years in
stamp paper in approved Format.

19 Sheeting to the roof shall be generally provided with authorised Laps, Gutters, Flashing, Bolts & nuts,
washers and all necessary accessories, welding the Gutter if required with consumables, stop ends
with in the quoted rates.

20 Tests on materials shall conform to IS Specification and the test shall be carried out as directed
either at site Laboratory or at any approved test laboratory.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 20 7. Structural Steel
Tidel, Coimbatore Preamble to Bills of Quantities

PREAMBLE TO THE BILL OF QUANTITIES - 8. FLOORING WORKS

Unless otherwise specified, the rates quoted for items under Flooring works shall include the following :

1 Cost of all materials, labour, equipment / tools & plants required, conveyance, infrastructure facilities
required etc..

2 Work at any depth below ground level or any height above ground level and at all levels, heights &
elevation and location.

3 All scaffolding, ladders, platforms, staging and plant required in the execution of work to any height and
depth.

4 Final preparation of base sub-grade or sub-floor by cleaning of all dust/dirt, loose particles, caulked mortar
dropping by scrubbing with coir or steel wire brushes, caulking etc. Roughening surface if so directed,
cleaning with water and keeping surface wet for 12 hours and removing surplus water by mopping before
topping is laid and minor trimming of the base to remove undulations.

5 Cleaning, preparation of surface and watering immediately before laying the floor as directed.

6 Providing bedding layer of mortar for flooring / skirting / dadoing / steps shall be as specified in bills of
materials either in the case of slabs or tiles, etc. to correct levels and gradients as called for.

7 Cutting, rubbing and polishing where applicable (both machine and hand) including grinding, rubbing,
acid cleaning, wax and tin-oxide polishing etc.

8 Keeping the surface wet for a minimum period of one week.

9 Providing all Marble and granite slab / tile flooring, skirting, dadooing with neat white cement slurry coat
to the required thickness over bed mortar before laying the slab/tile. All cladding works in marble and
granite slab/tile etc,shall be provided with requisite brass / gun metal clamps / stainless steel clamps and
keys in required sizes and pattern.
Unless noted otherwise in the bills of materials brass / gun metal clamps / stainless steel clamps and keys
shall be suitably designed to the requirement of internal wall cladding and to be designed to the specified
wind pressure in the case of external wall cladding.

10 Providing vitrified ceramic tile,ceramic tile, glazed tile flooring with the clamps bedding layer of mortar as
specified in the bill of quantities .

11 Providing vitrified ceramic tile, ceramic tiles glazed tile skirting and dadoing with bedding layer of mortar
as specified in the bill of quantities or with bedding layer of "ROFF TILE Water proof Tile Adhesive or
equivalent "Laticrete product" for fixing and pointing shall have Roff Tile Joint Fillers or equivalent
"Laticrete product" of approved shade and colour as per Manufacturer's Specification.

12 All vitrified ceramic tile, ceramic tile, glazed tile skirting and dadoing shall have final light acid cleaning,
as directed.

13 Work in jambs, soffits and sills of openings in Lift entrance/ Main entrance shall be arranged to match with
the surrounding finishes and as directed.

C.R.Narayana Rao
Architects & Engineers 21 8. Flooring works
Tidel, Coimbatore Preamble to Bills of Quantities

14 Formation of vertical grooves on vertical surfaces and provision of mortar bed of required thickness to
achieve proper level/slope.

15 Provision in small quantities, narrow width, mitred and returned ends, sinking, risers, set back and any
other sundry items for cutting, fixing, making good upto and which may be required for forming base.

16 Any additional mortar or concrete required to bring the surface to the required level and gradient before
laying the base mortar at no extra cost.

17 Machine crushed coarse graded aggregate shall be hard broken blue granite of sizes specified only to be
used for concrete works.

18 Cement used for all flooring works shall be High strength ordinary portland cement Grade- 43.

19 Coarse graded sand shall be used for mortars in all flooring works.

20 Tests on materials shall conform to IS Specification and the test shall be carried out as directed either at
site Laboratory or at any approved test laboratory.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 22 8. Flooring works
Tidel, Coimbatore Preamble to Bills of Quantities

PREAMBLE TO THE BILL OF QUANTITIES : 9. INTERNAL & EXTERNAL FINISING WORKS.

Unless otherwise specified, the rates quoted for items under Internal & External finishes shall include the
following:

1 Cost of all materials, labour, equipment / tools & plants required, conveyance, infrastructure facilities
required etc..

2 Work at any depth below ground level or any height above ground level and at all levels, heights &
elevation and location.

3 Works internally and externally at any heights and in any position or shape as directed..

4 Providing scaffolding, staging, working platforms, ladder, plants etc., as required and removal of the same
after completion of the work.

5 Hacking and for bush hammering to form key for plaster and for better dash treatment as and where
necessary.

6 All work in narrow width haunching chamfered drips external angles, drip moulds to chajjas, balcony,
parapet projections etc.

7 Providing and fixing a layer of GI chicken mesh (Double folded) to a required width at the junctions of
concrete and brick work before plastering and curing the works.

8 Providing and fixing GI corner beads of ARPITHA EXPORTS or equivalent in all edges of plastering and
isolated column, column projections everywhere.

9 Providing plaster grooves wherever different materials are used and at junctions of RCC members and
masonry works both in ceiling and on walls and the junctions at wall & openings,as directed.

10 Hacking or roughening concrete surface, ceilings or masonry surface by raking out joints, preparing and
wetting the surface to receive the plaster / paint and curing etc. complete.

11 Holes on the walls shall not be made to provide support to the single scaffolding, staging,working platform
etc.

12 Different grades of coarse sand required for use of work including sieving sand to get the required grade of
sand.

13 Making the surface well watered and thoroughly soaked for atleast 12 hours prior to plastering.

14 Keeping the plastered surfaces wet continuously for a period of 7 days after the completion of the item in
any area by proper spraying of water.

15 Neat finishing of junctions of plaster at the junctions of skirting, dadooing and cladding works.

16 Washing floors, cleaning of glass, aluminium works, aluminium composite Panel, flooring works, cladding
works shall be carried out to ensure the premises is clean and tidy after completion of plastering and
painting works.

C.R.Narayana Rao
Architects & Engineers 23 9. Int. & Ext. finish
Tidel, Coimbatore Preamble to Bills of Quantities

17 Work in jambs, soffits and sills of openings shall be carried out as directed.

18 Providing plaster in small areas & quantities, narrow width, mitred and returned ends, sunken areas, risers,
making the surface good upto and which may be required for forming good finish. Any additional plaster
required to bring the surface to the required level and plumb shall be carried out at no extra cost.

19 Tests on materials shall conform to IS Specification and the test shall be carried out as directed either at
site Laboratory or at any approved test laboratory.

20 Cement used for all finishing and plastring works shall be Portland Pozzalona Cement of 33 Grade.

21 Paint shall be applied as per the specification and to Manufacturers specification & instructions.

22 Curing, protecting the painted surface, adjacent work and thoroughly cleaning of the premises.

23 Paint shall be ready mixed and of first quality of the approved brand and manufacturer. The paint shall
generally conform to the chemical composition and other characteristics laid down in the relevant Indian
standard specification.

24 Mixing of paint by the Contractor at site will not be allowed.

25 In the case of selection of special shades and colours (not available standard shades), the Contractor shall
mix different shades of ready mixed paints at approved place and as per Manufacturers instructions.

26 Materials shall be the highest grade products of well known approved manufacturers. It is desired that
materials of one manufacturer only shall be used as far as possible and paint of one shade be obtained
from the same manufacturing batch. All paints shall be subjected to analysis from random samples taken
at site from the painters bucket, if so desired.

27 Any materials found not conforming to the relevant specification shall have to be removed by the
Contractor from the site at no extra cost.

28 All primer coats shall be compatible to the material of the surface to be finished as well as to the finishing
coats to be applied.

29 Lime for white washing shall be pure shell lime or fat lime, or a mixture of both and shall conform to IS:712
and approved lime shall be brought to site in an unslaked condition.

30 Synthetical enamel paint shall be in a smooth, hard, durable and glossy finish to all exterior and interior
surfaces and it shall conform to IS:2932 and IS:2933.

31 Waterproof Cement Paint Shall conform to IS:5410.

32 Dry distemper of required colour conforming to IS:427.The primer where used shall be cement primer or
distemper primer of same manufacturer as that of distemper.

C.R.Narayana Rao
Architects & Engineers 24 9. Int. & Ext. finish
Tidel, Coimbatore Preamble to Bills of Quantities

33 Acrylic Emulsion Paint Shall be in accordance with the specification. The paint should be able to withstand
washing with mild soap and water without any deterioration in colour or without showing flaking, blistering
or peeling after its dried.

34 Oil bound distemper shall confirm IS:428. The primer where used be cement primer or distemper primer of
same manufacturer as that of distemper. The distemper shall be diluted with prescribed thinner in a
manner recommended by the manufacturer.

35 Chemical resistant paint shall confirm IS:157 and the primer coat shall be used as per manufacturers
specifications.

36 Fire resisting paint (silicate type & waterbased) shall confirm IS:162 and and the primer coat shall be used
as per manufacturers specifications.

37 Oil resistant paint shall confirm IS:161 and and and the primer coat shall be used as per manufacturers
specifications.

38 French polish shall be an approved make conforming to IS : 348.

39 Concrete / masonry surface and cement plastered surfaces shall be thoroughly cleaned of mortar
droppings and other stickings. All loose scales and flakes shall be removed by rubbing with hessian cloth
or sand papering. All holes shall be filled and the surface rubbed smooth to get evenness of the existing
surface. The surface shall be free from all oil, grease, efflorescence, mildew, loose paint or other foreign
and loose materials. Masonry cracks shall be cleaned out and patch filled with mortar similar to the original
surface and uniformly textured. Where this type of resurfacing may lead to the finishing paint being
different in shade from the original surfaces, the resurfaced area shall be treated with a minimum of one
coat of cement primer and should be continued to the surrounding area for a distance of atleast 100mm.

40 Painting work on wood, steel and iron surface shall conform to IS : 1477 and one shop coat of red oxide or
zinc chromate primer or as specified shall be given to all iron surfaces. Preparation of surface by sand
papering in the case of wood works and wire brushing/sanding or chemical removal of rust and scaling in
the case of steel work.

41 All primer coats shall be compatible to the material of the surface to be finished as well as to the finishing
coat to be applied.

42 No painting shall be done when plastering is in progress or is drying. Paint which seals the surfaces to
moisture shall be applied only after the moisture on and below the surface has dried out.

43 All coats shall be thoroughly dry before being sand papered or before the succeeding coat is applied.
Coats of painting as specified are intended to cover surfaces perfectly. In case the surface is not covered
properly by applying the specified number of coats, further coats shall be applied by the Contractor when
so directed by the Engineer at no extra cost.

44 All parts of mouldings and ornaments shall be left clean and true to finish after completion of painting.

45 Stopping and filling carpentry work should be carried out when the primer is just dry. Providing deep
scratches,holes,stopping with putty of plastic wood confirming to IS 423. The putty shall be white lead with
linseed oil base or synthetic metal putty.

C.R.Narayana Rao
Architects & Engineers 25 9. Int. & Ext. finish
Tidel, Coimbatore Preamble to Bills of Quantities

46 Providing filling to the all minor scratches and rough surfaces, like flush doors faces shall be made out of
one part of white lead, two parts of whiting (powdered chalk) mixed and kneaded in double boiled linseed
oil shall be evenly applied and rubbed down with G/220 or G/240 sand paper after allowing it to dry .

47 Painting shall be done by skilled labourers in a workmanlike manner. All materials shall be evenly applied
so as to be free from sags, runs, crawls, or other defects. All coats shall be of proper consistency and
shall be well brushed out, so that no brush marks are visible, except varnish and enamels which shall be
uniformly flowed on. The brushes shall be clean and in good condition before application of paint.

48 Ready mixed synthetic enamel paint or fill paint may be used for the undercoat. The undercoating should
be nearest to the specified colour of the finishing coat and shall be uniform and free of all brush marks.

49 Undercoats should be completely dry before finishing coat is taken up. For synthetic enamels overnight
and for oil paints, a whole day shall be left between undercoat and finishing coat. The undercoat shall then
be rubbed with G/240 sand paper and dusted clean. The finishing coat of approved paint shall then be
applied. If the surface is not satisfactory additional finish coats shall be applied at no extra cost. The
paints shall be applied with bristle brushes and not horse hair ones.

50 When the final coat is applied, if directed, the surface shall be rolled with a roller or if directed it shall
be stippled with a stippling brush.

51 All painted surfaces shall be uniform and pleasing the appearance.The colour, texture etc. shall match
exactly with approved samples. All stains, splashes and splatters of paint shall be removed from
surrounding surfaces.

52 Ceiling of basement floor is not intended to be plastered but finished under form finish with neat cement
wash only. Hence, shuttering must be of such type that uniform and level finish is obtained without
requiring plastering.However rate shall include neat cement wash. Cost to include deburring of shuttering
joints and ensuring smooth finish as directed.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 26 9. Int. & Ext. finish
Tidel, Coimbatore Preamble to Bills of Quantities

PREAMBLE TO THE BILL OF QUANTITIES - 10. MISCELLANEOUS WORKS

Unless otherwise specified, rate quoted for Miscellaneous works shall include the following:

1 Cost of all materials, labour, equipment, tools & plants required, conveyance, infrastructure facilities
required etc..

2 Work shall be at all levels, heights & elevation and location.

3 All reinforcement steel shall be the grade of Fe 500 CRS or Fe 500 or Fe 415 or mild steel and shall be
used as specified elsewhere in the Bills of mateirals. Unless otherwise noted in the bills of Quantities,
method of measurements shall be generally in accordence with IS 1200. Reinforcement shall be
measured only in lengths of bars as actually placed in position on standard weight basis, no allowance
being made in the weight for rolling margin. Authorised laps and splices only will be measured. Chairs
of any shape & profile, Spacer bar of any shape & profile, cover block,wastage and binding wire will not
be measured and shall be included in the quoted rates.

4 Cement for all works shall be High strength ordinary portland cement Grade 43.

5 Coarse graded sand shall be used.

6 Machine crushed coarse graded aggregate shall be hard broken blue granite of sizes specified only to
be used for concrete works.

7 All materials supplied shall be free from manufacturing defects and defective workmanship and
guaranteed. Any defects noticed shall be made good,at no extra cost

8 Tests on materials shall conform to IS Specification and the test shall be carried out as directed either
at site Laboratory or at any approved test laboratory.

9 Provide all materials, hardwares, bolts and nuts, washers, any fastening materials and devices, anchor
fasteners shall be of approved make and conform to IS specification if required.

10 All Specialized items shall be pre-ordered and to be carried out only on prior approval.

11 Hardware fittings and fixtures shall be made with structural properties to sustain safety and withstand
strains and stresses to which they are normally subjected, such as opening and closing, wind pressure
etc. Fittings shall generally conform to relevant IS specifications.

12 Hardware fittings shall be made true, clean, straight, with sharply defined profiles and unless otherwise
shown or specified, with true smooth surfaces and edges, free from defects, screw holes shall be
counter sunk to suit the head of wood screws.

13 Metal shall be treated with finish as specified in the Bill of Quantities.

14 All other specified Hardware fittings shall be free from defects impairing strength, durability or
appearance and of the best quality obtainable for their particular function and situation in structure and
the approved fittings only shall be used.All screws shall be of best quality stainless steel Mild Steel
Copper Oxidised or brass.Weight and / or thickness of the fittings without screws shall be in accordance
with IS.

C.R.Narayana Rao
Architects & Engineers 27 10-Miscellaneous works
Tidel, Coimbatore Preamble to Bills of Quantities

15 Hardware fittings like aldrops, handles and knobs etc., shall be fitted to the joinery items with the
machine threaded stainless steel screws from the back side in addition of regular screws and nuts so as
not to permit removal of fittings from the side where fittings are seen.

16 Aldrops shall be of aluminium colour anodised or as specified and shall be capable of smooth sliding
action. Aldrops shall conform to I.S 281. In case of single leaf door, hole of suitable size shall be made
in the door frame and a plate cut to shape shall be fixed at the face of the hole. Generally, size of
aldrop shall be taken as the length of the rod.

17 Sliding Bolts / Latches shall be of stainless steel /M.S Brass / aluminium colour anodised and shall be
capable of smooth sliding action. Generally, size of latch shall be taken as the length of the bolt catch.

18 Tower Bolts shall be aluminium colour anodised from extruded section/ brass. Tower bolts shall be
provided with steel spring and ball shall be provided between the sheet and the barrel. Size of tower
bolts shall be taken as the length of barrel without top socket.

Date : Signature of the Contractor

Place :

C.R.Narayana Rao
Architects & Engineers 28 10-Miscellaneous works
TIDEL PARK COIMBATORE LTD
( A JV OF TIDCO, ELCOT, TIDEL & STPI )
BUILDING COMPLEX OF INFORMATION TECHNOLOGY PARK AT VILANKURICHI
(SEZ AREA), COIMBATORE

BILLS OF QUANTITIES FOR SHELL & CORE, CIVIL FINISHES & SUBSIDIARY WORKS

GENERAL SUMMARY (QUOTED AS SEZ PROJECT)


TOTAL Amount (Rs.)
S.No Description of work

SECTION 3A - MAIN BUILDING - SHELL & CORE

1 Earthwork Excavation

2 A nti-Termite Treatment Works

3 Plain & Reinforced Cement Concrete Works

4 Form Works

5 Iron & Steel Works

5 Post - Tensioning Works

6 Water Proofing Works

7 Miscellaneous Works
Sub - Total of 3 A in Rs.

SECTION 3B - MAIN BUILDING - CIVIL FINISHES TOTAL Amount (Rs.)

1 Masonry Works

2 Flooring & Dadoing Works

3 Joinery Works

4 Internal & External Finishes


Sub - Total of 3 B in Rs.

C.R. Narayana Rao


Architects Engineers 29 SEZ Format
SECTION 3C - SUBSIDIARY WORKS TOTAL Amount (Rs.)

1 Roads & Pathways

2 Drains &Trenches

3 Compound Wall

4 HSD Tank

5 Sewage Treatment Works

6 UnderGround Sump
Sub - Total of 3 C in Rs.

SECTION 3 D - SUB-STAION BUILDINGS, SECURITY & DRIVER'S REST ROOM TOTAL Amount (Rs.)

1 Sub-Station Buildings

2 Secutiry Buuilding

3 Driver's Rest Room


Sub - Total of 3 D in Rs.

Grand Total of 3A to 3 D in Rs.

Total Value of Contract quoted


Rupees ____________________________________________________________________

_____________________________________________________________________only

Date :
Place :

C.R. Narayana Rao


Architects Engineers 30 SEZ Format
Tidel, Coimbatore

TIDEL PARK COIMBATORE LTD


( A JV OF TIDCO, ELCOT, TIDEL & STPI )
BUILDING COMPLEX OF INFORMATION TECHNOLOGY PARK AT VILANKURICHI
(SEZ AREA), COIMBATORE
BILLS OF QUANTITIES FOR SHELL & CORE, CIVIL FINISHES & SUBSIDIARY WORKS

SECTION 3A,3B,3C & 3 D - SHELL & CORE , CIVIL FINISHES , SUBSIDIARY, SUBSTATION, SECURITY &
DRIVER'S REST ROOM

S.No Description Unit Qty Rate Amount

1.00 EARTHWORK EXCAVATION


GENERAL NOTES FOR EXCAVATION
Contractor shall take all required permissions from the
appropriate authorities for Excavation, Blasting, Carting
away materials including depositing, levelling etc. and shall
bear all the expenses for the same.
Rate includes removal of all kind of vegetation,small shrubs
etc. Dewatering water to be let out of the building / site area
through proper pipes & channels if required. The contractor
at his own expenses shall water very well, ram and
thoroughly consolidate the bottom of all excavations &
ground before the construction of foundation/footing/plinth
beam, filling in basement floor or other work is
commenced.The rate for excavation shall include for
shoring sides or trenches with approved timber/steel
accessories wherever necessary to prevent sides from
falling including bailing or pumping out of water if necessary
and include If there are any shrubs, bushes, trees, roots of
the trees to be removed for min depth 50. Necessary Lift &
lead for all type of excavated materials to convey them and
to deposit them as directed by the engineer-in-charge are to
be considered.

Contour level to be taken jointly with the engineer-in-charge


and prior written approval to be taken before starting any
excavation/ filling at every 3 / 5 mt grids or at regular
intravels as directed by the engineer -in-charge for arriving
at the actual quantity. Measurements for filling will be taken
for consolidated thickness only.Cost to include all and
necessary royalty and other permission charges required to
execute the works.Unless noted otherwise measurements
shall be considered to the edge of PCC only.

Note: The measurements shall be based on the levels


captured prior and after execution. And in case of stack
measurement, the percentage of 40 % of voids to be
deducted from stack measurement for hard rock (Incase
operated). Blasting shall be carried through licensed
operator having valid blasting licence.

C.R.Narayana Rao
Architects &Engineers 31 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

1.01 General Excavation by mechanical means in all types of soil


including dense soil, discentegrated/ weathered/ soft rock
for any type of foundation including necessary manual
excavation for dressing the edges & leveling, all leads and
lifts back filling in layers of 150mm with watering and
compaction to the required proctor density . Rate to include
disposing the excess earth and spreading in layers to the
required levels within the site wherever
specified,dewatering of both ground and surface water,
Cum 1500
removal of slurry generated while excavation and keeping
the area free of water with necessary shoring, struting,
required for keeping earth in position etc,. excavating loose
pockets and compacting the same. Note: Aut
working space and Provision of slopes if required for
execution shall not be paid separately.
Excavation in all types of soils to any depth below ground
level.

1.02 Excavation in Medium rock ( more than 1/2 Cum in size -Un-
poclainable) to the required level & depth (Mass
excavation) including all leads and lifts, stacking excavated
material within plot at approved location , if required de-
watering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
of water with necessary shoring, strutting, stepping, Cum 500
dressing, grading required for keeping earth in position etc.
as per detailed specificationand conforming to safety rules
during progress of the work. Note:Authorised working
space and Provision of slopes if required for execution
shall not be paid separately.

1.03 Same as item No - 1.01 but for general excavation in Hard


rock/ boulders (more than 1/2 Cum in size -Un-poclainable)
by chiselling/ wedging to the required level & depth (Mass
excavation) including all leads and lifts, stacking excavated
material within plot at approved location , if required de-
watering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
of water with necessary shoring, strutting, stepping, Cum 2000
dressing, grading required for keeping earth in position etc.
as per detailed specificationand conforming to safety rules
during progress of the work. Note:Authorised working
space and Provision of slopes if required for execution
shall not be paid separately.

C.R.Narayana Rao
Architects &Engineers 32 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

1.04 Excavation in hard rock / boulders (more than 1/2Cum in


size) by Controlled Blasting using explosives and trimming
to required level for foundation, trenches, rafts, plinths,
leveling area etc. to the required depth at all leads including
stacking excavated material within plot at approved
location, if required bailing /pumping out of water to keep
site dry at all times until completion of work; shoring, Cum 500
strutting, stepping, dressing, grading, cleaning, removing
and excavating loose pockets as directed etc. all complete
as detailed in specification and conforming to safety rules of
authority from time to time and Explosives rules1940 or as
amended.

1.05 Carting away surplus earth/excavated material/debris and


like materials outside the site and disposing off the same to
the designated areas as identified by the local
authorities/engineer-in-charge for dumping of such
Cum 500
material,including spreading,compacting etc.,as per the
norms by the local authorities etc complete as sirected in all
respects.

1.06 Supply and filling in foundations and the area whereever


specified with approved good quality filling materials in
plinths, sides of retaining wall alround the building ( i.e
backfilling ) area development etc. wherever specified in
layers of not exceeding 150 mm thick including breaking
clods,storing,transportation ,double handling, watering,
compacting each layer with vibratory compactor and at
unaccessible places with wooden/steel rammers to achieve
90 to 95% proctor density at optimum moisture content, all
leads and lifts, bailing/ pumping out of water to keep site dry
while backfilling; cost shall include conveyance of all
materials, labour, machinery etc. complete as directed.The
rate to include loading,unloading, hire and fuel charges for
tools and plants and other incidental charges etc., complete
as directed.

a With approved quality murrum brought from outside. Cum 8000


b Approved quality river sand brought from outside Cum 8000
c With approved quality quarrydust brought from outside Cum 8000
1.07 Filling with available excavated earth (excluding rock)
wherever required including sides of retaining wall and in
trenches, plinth, sides of foundation etc, in layers not
exceeding 150 mm thick in depth, consolidating each Cum 20000
deposited layer by ramming and watering for all leads within
the construction site and for all lifts.

C.R.Narayana Rao
Architects &Engineers 33 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

1.08 Supplying and filling in foundations and the area


wherever required below and above ground level with the
approved materials detailed delow, in layers not
exceeding 150 mm thickness, including mixing, spreading,
levelling, watering and consolidating each layer with power /
hand roller of required capacity to obtain required proctor
density etc. all complete and as directed. Rate shall
include for loading, unloading, transportation, hire and fuel
charges for tools and plants employed and other incidental
charges etc. complete and as directed.

a Sand Gravel mix in proportion of 1:1 with approved


good quality Gravel and river sand from approved Cum 500
source.
b Sand lime (slaked) mix in proportion of 1:1 with
approved good quality slaked lime and river sand from Cum 500
approved source.
1.09 Providing and laying in position 150mm thick soling with
approved Base preparation by Mechanical compaction,
using hard granite stones / Rubble and smaller pebbles for
void filling, moorum for binding as directed by the Engineer-
in-charge including watering,packing, compaction etc., with Sqm 500
required tools and plants and all lead,lift, conveyance as
required etc., complete as directed.

1.10 Providing and laying 600 micron guage polythene


paper/Polythene sheet below Grade slab,P.C.C,Raft slab
etc., to the required levels, including supply,loading and Sqm 125
unloading,storing,tranportation,laying,sealing of junctions
and overlaps, all leads and lifts, etc.,complete

Total C/o.to Summary of 3 A in Rs.

2.00 ANTI TERMITE TREATMENT WORKS


2.01 Providing Anti termite treatment in accordance with
stipulations laid down by IS 6313 - part II by approved
agency with min of 10 years of guarantee including the cost
of chemical,precautionary measures etc.complete along
retaining walls only for a width of one meter or as specified
by consultants (treatment for floor is not required and Sqm 600
agency shall be approved by engineer-in-charge
Note: External periphery length of the retaining wall
multiplied by 1 M will be considered as the measurement
area.
Total C/o.to Summary of 3 A in Rs.

3.00 PLAIN & REINFORCED CEMENT CONCRETE WORKS


3.01 Providing and laying plain cement concrete 1:4:8 using
coarse graded aggregate of 40 mm and down size for
levelling course under footings, steps, walls, platform etc. Cum 25
including form work wherever necessary and well
compacted etc. all complete, as directed.

C.R.Narayana Rao
Architects &Engineers 34 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.02 Providing and laying P.C.C. 1:3:6 of specified thick


wherever specified using river sand, 20mm and downsize
metal including base reperation, Compaction, levelling, all
Cum 4900
leads and lifts, curing and shuttering if necessary etc.,
Complete

3.03 Providing and laying P.C.C. 1:2:4 of specified thickness


wherever specified using river sand, 20mm and downsize
aggregate including cleaning,subgrade preparation,
Compaction, levelling, all leads and lifts, rough finishing at
the top surface,curing and shuttering if necessary etc.,at all
heights and depths as instructed.

a DPC , Copings,Flagging concrete,shaft screed etc., Cum 25

READY MIX CONCRETE / CONTROLLED CONCRETE

NOTE: RMC SHALL BE PROCURED FROM SITE


BATCHING PLANT HOWEVER, IN CASE OF READY MIX
CONCRETE PROCURED FROM RMC PLANT THE
PROBABLE CONCRETE CAN BE FETCHED FROM (L&T/
IJM/ Redimix).

Providing, batching, mixing, transporting through transit


mixers, pumping and laying controlled Reinforced Cement
Concrete of specified grade at all levels and heights
specified below using ordinary Portland cement of grade 53
/ grade 43 from approved manufacturer, river sand, 20mm
and down size coarse aggregates, necessary Mineral
admixtures approved by Consultants (elkem and Conplast
SP 430SRV from Fosroc or equivalent), including all leads
and lifts, pumping using line pump or boom placer,
vibrating/ compaction, scaffolding wherever necessary,
curing as directed, excluding cost of shuttering and
reinforcement works.

(Design mix shall be as approved by the Structural


Consultant / Employer's representatives

3.04 Columns at

M45 Grade
Basement 3 Cum 1150

Basement 2 Cum 1150

Basement 1 Cum 1250

M40 Grade
Ground floor Cum 950

First Floor Cum 950

Second Floor Cum 950

C.R.Narayana Rao
Architects &Engineers 35 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

M35 Grade
Third Floor Cum 950

Fourth Floor Cum 950

M30 Grade
Terrace Floor Cum 125
3.05 Columns drops / Solid portion at

M45 Grade
Basement 2 Cum 1800

Basement 1 Cum 1800

Ground floor Cum 1800

M40 Grade
First Floor Cum 1700

Second Floor Cum 1700

Third Floor Cum 1700

M35 Grade
Fourth Floor Cum 1700

Terrace Floor Cum 1700


3.06 Core Walls at

M40 Grade
Basement 3 Cum 450

Basement 2 Cum 300

Basement 1 Cum 330

M35 Grade
Ground floor Cum 250

First Floor Cum 250

Second Floor Cum 250

M30 Grade
Third Floor Cum 250

Fourth Floor Cum 250

Terrace Floor Cum 325


Flat Slabs (including Conventional slab)/Panelled slabs
3.07
at all levels

M30 GRADE
Basement 2 Cum 5450

Basement 1 Cum 5450

Ground floor Cum 6000

C.R.Narayana Rao
Architects &Engineers 36 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

M40 GRADE
First Floor Cum 4150

Second Floor Cum 4150

Third Floor Cum 4150

Fourth Floor Cum 4150

Terrace Floor Cum 4150

Above Terrace Cum 400


3.08 Beams at all levels

M30 GRADE
Basement 2 Cum 350

Basement 1 Cum 350

Ground floor Cum 325

First Floor Cum 400

Second Floor Cum 400

Third Floor Cum 400

Fourth Floor Cum 400

Terrace Floor Cum 400

Above Terrace Cum 250


3.09 M45 GRADE CONCRETE

Retaining wall
i Basement 3 Cum 785

ii Basement 2 Cum 785

iii Basement 1 Cum 630


3.10 M30 GRADE CONCRETE

a RCC Parapet at all levels of specified thickness Cum 125

Footings/ Rafts for columns,Core walls/ Retaining walls Cum 15000


b etc.,
c Grade slab / Raft Slabs Cum 6100

d Ramp slab Cum 425

e Ramp Beam Cum 100

f Staircase including the Landings


i Basement 3 Cum 85

ii Basement 2 Cum 85

iii Basement 1 Cum 100

iv Ground floor Cum 80

v First Floor Cum 80

C.R.Narayana Rao
Architects &Engineers 37 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

vi Second Floor Cum 80

vii Third Floor Cum 80

viii Fourth Floor Cum 80

ix Terrace Floor Cum 80

g Lintels at all levels


i Basement 3 Cum 2

ii Basement 2 Cum 2

iii Basement 1 Cum 2

iv Ground floor Cum 6

v First Floor Cum 6

vi Second Floor Cum 6

vii Third Floor Cum 6

viii Fourth Floor Cum 6

ix Terrace Floor Cum 2

h RCC Brackets/Fins/Ledges/lofts at all levels Cum 10

i Pedestals , foundations for Equipments Cum 100

j Mullion columns at all levels Cum Qro


k Strom Water collection sumps
i Bottom slab Cum Qro
ii Walls Cum Qro
iii Top slab Cum Qro
l Domestic and Fire fighting Overhead Tank
i Bottom slab Cum 15
ii Walls Cum 50
iii Top slab Cum 15
3.11 Supplying, drilling and fixing MS anchor rod of 16 mm dia
into the hard rock for 200 mm below footing and 200 mm
anchoring into the footing.Rate shall include for all material Nos 500
and labour etc, complete

3.12 M25 Grade Concrete


a. RCC Parapet at all levels of specified thickness Cum Qro
b Lintels at all levels Cum Qro
c RCC Brackets/Fins/Ledges at all levels Cum Qro
d Cill concrete/Fins /Chejjas/Lofts at all levels Cum Qro
3.13 M20 Grade Concrete
a. RCC Parapet at all levels of specified thickness Cum Qro
b Lintels at all levels Cum Qro
c RCC Brackets/Fins/Ledges at all levels Cum Qro
d Cill concrete/Fins /Chejjas/Lofts at all levels Cum Qro
Total C/o.to Summary of 3 A in Rs.

C.R.Narayana Rao
Architects &Engineers 38 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.00 FORM WORK


4.01 Providing, fabricating and erecting form work at all levels
and places wherever needed/specified as per drawing
including striking with 12mm Plastic coated, marine
resistant waterproof ply/Smooth finished MS plates with
adjustable steel props of acceptable Staging system and
with sufficient bracing as approved by consultant. Cost to
include designing of proper form work and staging system
to suit the requirements,Submission of design calculations
and shop drawings for approval,sealing the joints with
heavy duty brown self adhesive tape, aligning to line and
levels including M.S. Ties, PVC Spacer, Providing
openings/ cutouts/ pockets, applying deshuttering chemical,
Deshuttering as approved by the consultant etc., complete
at all levels, double/tripple heights and profiles for Note :
Only plan area shall be considered.No extra shall be paid
for Side shuttering of Drop panel/column capitals.

1) plywood shuttering shall be considered for all vertical


elements,beam
soffit,corewalls,stairs,ramps,tanks,RCCpedestals Etc.,
2) M.S. plates shall be considered for foundation,slabs
only.
3) Shuttering & deshuttering sequence shall be 100% ,80%
& 40% from the slab to be cast respectively

a Columns at

Basement 3 Sqm 6000

Basement 2 Sqm 6000

Basement 1 Sqm 6600

Ground floor Sqm 5000

First Floor Sqm 5000

Second Floor Sqm 5000

Third Floor Sqm 5000

Fourth Floor Sqm 5000

Terrace Floor Sqm 600


b Core Walls at

Basement 3 Sqm 3100


Basement 2 Sqm 2000

Basement 1 Sqm 2200

Ground floor Sqm 1700


First Floor Sqm 1700

Second Floor Sqm 1700

Third Floor Sqm 1700


Fourth Floor Sqm 1700
Terrace Floor Sqm 2050

C.R.Narayana Rao
Architects &Engineers 39 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Flat Slabs (including Conventional slab)/Panelled slabs


c
at all levels

Basement 2 Sqm 19550

Basement 1 Sqm 19550

Ground floor Sqm 21200

First Floor Sqm 18400

Second Floor Sqm 18400

Third Floor Sqm 18400

Fourth Floor Sqm 18400

Terrace Floor Sqm 18400

Above Terrace Sqm 1750


d Beams

Basement 2 Sqm 3300

Basement 1 Sqm 3300

Ground floor Sqm 3100

First Floor Sqm 3800

Second Floor Sqm 3800

Third Floor Sqm 3800

Fourth Floor Sqm 3800

Terrace Floor Sqm 3800

Above Terrace Sqm 2200

4.02 RCC Parapet at all levels of specified thickness Sqm 1250


Footings/ Rafts for columns,Core walls/ Retaining walls
Sqm 11000
4.03 etc.,
4.04 Grade slab Sqm 2750

4.05 Retaining wall


i Basement 3 Sqm 5350

ii Basement 2 Sqm 5350

iii Basement 1 Sqm 4300

4.06 Ramp slab Sqm 2125

4.07 Ramp Beam Sqm 800


4.08 Staircase including the Landings

Basement 3 Sqm 595

Basement 2 Sqm 595

Basement 1 Sqm 700

Ground floor Sqm 560

First Floor Sqm 560

C.R.Narayana Rao
Architects &Engineers 40 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Second Floor Sqm 560

Third Floor Sqm 560

Fourth Floor Sqm 560

Terrace Floor Sqm 560


4.09 Lintels at all levels

Basement 3 Sqm 20

Basement 2 Sqm 20

Basement 1 Sqm 20

Ground floor Sqm 60

First Floor Sqm 60

Second Floor Sqm 60

Third Floor Sqm 60

Fourth Floor Sqm 60

Terrace Floor Sqm 20


4.10 RCC Brackets/Fins/Ledges at all levels Sqm 100
4.11 Pedestals , foundations for Equipments Sqm 300
4.12 Mullion columns at all levels Sqm Qro
4.13 Strom Water collection sumps
a Bottom slab Sqm Qro
b Walls Sqm Qro
c Top slab Sqm Qro
4.14 Domestic and Fire fighting Overhead Tank
a Bottom slab Sqm 65
b Walls Sqm 500
c Top slab Sqm 65
4.15 Providing, fixing reinforced cement concrete precast slab
with controlled cement concrete - M20 grade using coarse
graded aggregate 20 mm and downsize. Rate shall include
for providing necessary casting platform, shuttering,
finishing the exposed faces smooth wherever necessary
and pointing the joints with C.M 1:3, 15 mm thick curing
and fixing in position etc complete and as directed. Rate
shall include for fixing MS angles of required size based on
the thickness of precast slab and to be fixed on the edges
of the precast slab including grouting the lugs with Cement
concrete 1:1.5:3, GI Hooks for lifting the slab etc complete,
as directed. Necessary reinforcement MS angles,MS
lugs,GI hooks will be paid seperately in the respective
items.

a. 200 mm thick Sqm 25


b. 150 mm thick Sqm 25
c. 125 mm thick Sqm 25

C.R.Narayana Rao
Architects &Engineers 41 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

d. 100 mm thick Sqm 25


e. 75 mm thick Sqm 25
f. 50 mm thick Sqm 25
4.16 Providing and fixing precast reinforced cement concrete jalli
work, with controlled cement concrete - M - 20 grade using
coarse graded aggregate of 6 mm and downsize as per
drawing including fixing in position with cement mortar 1:3.
Rate shall include for cost of form work wherever required
etc complete and as directed..Necessary reinforcement will
be paid seperately in the respective items.

a. 100 mm thick Sqm 25


4.17 Extra for additional 3.65m height in centring, shuttering,
staging and scaffolding where ever required with adequate
bracing, propping etc. including cost of de-shuttering and
decentring at all levels, over and above the initial 3.65 m sqm 400
floor height, (Only plan area of such centring location will be
measured for payment).

Total C/o.to Summary of 3 A in Rs.


5.00 IRON & STEEL WORKS
5.01 Providing and fixing reinforcement for RCC work with
Thermo mechanically treated (TMT) bar of various
diameters and grade of steel as specified below conforming
to IS or equivalent BS specification including cutting and
waste, bending, hoisting, fabricating and placing in position
according to drawings and binding the reinforcement with
galvanised annealed binding wire of double fold of 18
gauge and providing PVC cover blocks for placing the
reinforcements in position and for maintaining the cover
specified and/or according to relevant IS or equivalent BS
code.
Note : Unless noted otherwise the measurements in
accordance with IS 1200 or equivalent BS. However
reinforcement shall be measured only in lengths of bars as
actually placed in position on standard weight basis, no
allowance being made in the weight for rolling margin.
Authorised laps and splices, couplers of any dia, Chairs of
any shape & profile, Spacer bar of any shape & profile,
cover block, wastage and binding wire will not be measured
and shall be included in the quoted rates.Quoted rate shall
be deemed to have considered the above
stipulation.Quoted rate to include lead, lift, placing at all
levels and as directed. Detailing of the reinforcement
shall be ductile detailing for seismic zone III as per
codal requirement.
I Grade of reinforced steel - Fe 500
MT 10650
5.02 Providing and fixing in position high strength welded wire
fabric mesh reinforcement of grade Fe 480 and 6mm thick
@ 150mm c/c (weight @ 2.966 Kg/sqm) with an overlap of
75 mm (confirming to IS 432/1982 Part-1) for slab including
cutting,placing in position according to drawings.

C.R.Narayana Rao
Architects &Engineers 42 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Note : Unless noted otherwise the measurements in


accordance with IS 1200 or equivalent BS. However
reinforcement shall be measured only in lengths of bars as
actually placed in position on standard weight basis, no
allowance being made in the weight for rolling margin.
Authorised laps and splices, couplers of any dia, Chairs of MT 5
any shape & profile, Spacer bar of any shape & profile,
cover block, wastage and binding wire will not be measured
and shall be included in the quoted rates.Quoted rate shall
be deemed to have considered the above stipulation.

5.03 Providing and fixing in position Hot rolled structural steel


Members / Sections at all levels and to any shape & profile
consisting of MS joists, channels, angles, purlins, runners,
insert plates, flats and sag rods with necessary sleeves,
bolts and nuts, gratings, pipes including cutting,
straightening, welding as per standards for connections
including consumables etc.complete. Rate shall include MT 150
preparation of surface, applying Zinc chromate/Phosphate
primer of one coat before and one coat after erection
including two coats of synthetic enamel paint of approved
make and colour etc. complete, as directed.

5.04 Providing, Fabricating and erecting in position structural


steel conforming to IS 800 as corner angles (50x50x6MM)
for columns, Edge angle for Catch pits and wherever
specified as per drawings. Cost to include necesary MS
flats for anchorages,hold fasts,anchor bolts,applying one MT 10
coat of Zinc chromate/Phosphate primer and two coats of
first quality synthetic enamel paint of approved make etc
complete,as directed.

5.05 Providing and fixing in position M.S.chequered plate 5mm


thick with necessary supports such as M.S. angles/M.S.
flats including stiffeners to be placed on angle iron frame
work. (Frame work, angles, stiffners will be measured under
relavent structural steel item). Rate shall include making
MT 5
necessary cutouts for inserts, applying one coat of Zinc
chromate/Phosphate primer and two coats of first quality
synthetic enamel paint of approved make and colour etc
complete,as directed.

5.06 Providing and anchoring in position high strength anchor


bolts of grade 5.8 and specified dia and standard lengths
including necessary drilling up to 150mm depth (min),
anchoring and grouting with necessary equipments etc.,
complete as per specifications of agency approved by
Consultants (HILTI or equivalent)

a 25mm dia / 250 long Nos 5


b 20mm dia / 250 long(heavy duty) Nos 5
c 16mm dia / 200 long (heavy duty) Nos 5
d 12mm dia / 150 long Nos 5

C.R.Narayana Rao
Architects &Engineers 43 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

5.07 Providing and fixing in position M.S.flat of size 100 x 6 mm


for tendon protection in post tensioned slabs as per the
details inlcuding necessary supports and hold fasts for
proper anchoring in concrete. Rate shall include making
necessary cut lengths fixed either at the bottom of the
sheathing or at the top,applying one coat of Zinc
chromate/Phosphate primer and two coats of first quality
synthetic enamel paint of approved make and one coat of
etch primer ( 8 microns thick ) and two coats of first quality
alkyd enamel paint ( 25 microns DFT ) each etc
complete,as directed.
a 100 x 6 mm MS flat at the soffit of the slab Rmt 1000
b Hot dip galvanised Flat of 100 x 6 at the top of the slab.
Glavanising should to IS 2629 & IS 4759 and the thickness Rmt 100
should be a minimum of 610 gms / sqm
Total C/o.to Summary of 3 A in Rs.
5.08 POST TENSIONING WORKS
Design and execution of post tensioning works including
decoiling the strands,cutting to the required
lengths,supplying and laying of HT strands sheathing (GI
corrugatedducts 0.3 mm thick) jointing with couplers,and
inserting the strands ,profiling,fixing live end anchorages
including the supply of stressing anchorages suitable for 5-
5 & 5-4 tendons, grout vents, making dead end anchorages
including flowering the strands ,fixing tendon support bars
,supervising the fixing of anti bursting
reinforcement,stressingthe cables end trimming,grouting the
cables with cement slurry mixed with admixtures with
required tools ,plants,machineries and consumables etc.,
(shuttering concreting & reinforcement steel shall be paid
under respective items), at all heights including all leads,
lifts, cooridination with the post tensioning agency,
preparation of drawings, optaining approval from the
consultants and architects etc.,Rate to include for providing
water, power, cement and admixture for grouting, packing
of sheathing and anchorages blockings,filling of recess
pockets after stressing using
high stength grouts incl. providing access
to post tensioning.
The contractor to submit the credentials of the agency hiring
for carrying out the above work. Sqm, 92000

Total C/o.to Summary of 3 A in Rs.

C.R.Narayana Rao
Architects &Engineers 44 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.00 WATER PROOFING WORKS


NOTE: Specialized agency to be approved by Client /
Consultants. PRINCIPAL MANUFACTURER SHALL GIVE
GUARANTEE FOR STIPULATED TIME FOR THE
WATERPROOFING WORKS DONE AT SITE. All surfaces
to be waterproofed should be sound, clean and dry.
Concrete surfaces should have a light steel-trowel followed
by a fine hair-broom or equivalent finish, which is dry and
free of dust, oil and other contaminants. All high spots
should be removed. Moss and lichen must be removed
physically followed by treatment with fungicidal wash to kill
any spores and inhibit further growth. After treatment wash
down thoroughly with clean water and allow to dry. Grouting
periphery of spout pipes with water insensitive epoxy,
pressure grouting of construction joints and honey comb
areas with cement grout, proper preparation of the concrete
surface by mechanical means/hydro blasting to ensure a
good bond between the topping and the substrate,Testing
of the surfaces prior to start the work,after completion and
after a period of one month after completion by
ponding,grouting or sealing of joints,making vatta at corners/j
rates Contractor shall give both material and preformance gu
the approved format.

6.01 Treatment on PCC levelling course below raft slab, lift


pits, Junctions of retaining and raft slab of main
building etc. covering the following sequence of operation :

a) Providing, supplying, mixing, laying cement screed


plaster 20 mm thick in cement concrete slurry 1:2:4 mixed
with 6mm & down grade course graded aggregate with
water proofing compound like CICO NO:1 (normal setting
integral water proofing compound) or approved equivalent
conforming to IS at the rate specified by the manufacturer
over PCC levelling course at any depth & height.

b) Providing, supplying, mixing, applying two coats of ready


to use two component Acrylic polymer modified cement
based, flexible, water proofing slurry like TAPECRETE or
approved equivalent to a thickness of 2 mm over the
plastered surface of operation above.

C.R.Narayana Rao
Architects &Engineers 45 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

c) Providing and laying water proofing treatment with


Membrane type water proofing methods using polymer
modified Bituminous membrane of CICO shield /Build
Wrap/ Deboer make or approved equivalent make. The
Atactic Poly-Propylene (APP) membrane shall have UV
resistant property, ground chemical resistant, high melting
points, flexible and elastic with high adhesive strength. The
membrane shall be reinforced with non woven polyester
reinforcement of minimum of 180 g/sqm and reinforced with
glass fibre grill of 8 g/sqm including coating with compatible
primer of Bituminous base whereever it is required and
torch application with overlap of 70 - 100 mm wherever
required. Cost to include laying by loose and torching the
prefabricated overlap at ends. The membrane surface shall
be procted with granules.

d) Providing, supplying, mixing, laying cement concrete


screed 40 mm thick with CC slurry 1:2:4 mixed with 12mm &
down grade course graded aggregate with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth & height.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 25000
plants, mixing device and gauge,Shuttering etc.complete as
per manufacturer's specification and as directed.

6.02 Providing chemical injection in the form of pressure grouting


to the raft slab, base slab of Lift pit, retaining walls of
basement lift pit from interior surfaces works at any depth,
height and level by injecting cement slurry mixed with grout
with CICO non shrink grouting compound or approved
equivalent admixed with cement slurry in the required
consistency through the prefixed GI nozzles in the 18mm
dia holes drilled in grid pattern at a spacing not exceeding 1
metre c/c on the top of base slab/retaining wall & surfaces
under pressure using grout pump. Nozzle fixing and
grouting for a retaining wall shall be only at construction
joints and honeycomb areas on approval.

C.R.Narayana Rao
Architects &Engineers 46 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Rate shall include for preparation of surface, de-watering,


drilling holes, using pneumatic hammer for fixing of GI
nozzles to the required depth, grouting admixture and finally
cutting the projected nozzles and sealing of the GI nozzles
after injection operation is over with CICO NO:3 quick
setting material or approved equivalent admixed with
cement, finishing, curing, etc., as per manufacturers
specification. Rate shall include for preparation of surface
by mechanical upgrading to remove all loose mortar and
laitance, oil, grease etc. and washing the surface with water
to get neat surface, dewatering, finishing, curing,
scaffolding, waterproofing chemicals, wastage,
conveyance, tools and plants, mixing device and gauge,
shuttering, Nozzles etc. complete as per manufacturer's
specification and as directed.

Mode of measurement:
Note : Item no. a) Top of raft slab of basement lift pit base
slab and UG sump base slab ie. width and length between
the retaining wall only will be measured and paid for.

Note : Item no. b) Grouting carried out on the vertical


surfaces(Internal) of the Retaining wall of the basement, lift
pit & UG sump will be measured and paid for.

a Raft slab & lift pits Sqm 20000


b Retaining walls of basement Sqm 17000
6.03 Treatment to side wall of varying thickness of basement
floor, Lift pit, of main building from exterior surface covering
the following sequence of operations :

a) Providing, supplying, mixing, applying two coats of ready


to use two component acrylic polymer modified cement
based flexible water proofing slurry like TAPECRETE or
approved equivalent conforming to IS to thickness of 2
mm on the surface of side wall prior to the chemical
injection treatment is completed as specified under item
above.
b) Providing and laying water proofing treatment with
Membrane type water proofing methods using polymer
modified Bituminous membrane of CICO shield /Build
Wrap/ Deboer make or approved equivalent make. The
Atactic Poly-Propylene (APP) membrane shall have UV
resistant property, ground chemical resistant, high melting
points, flexible and elastic with high adhesive strength. The
membrane shall be reinforced with non woven polyester
reinforcement of minimum of 180 g/sqm and reinforced with
glass fibre grill of 8 g/sqm including coating with compatible
primer of Bituminous base whereever it is required and
torch application with overlap of 70 - 100 mm wherever
required. Cost to include laying by loose and torching the
prefabricated overlap at ends. The membrane surface shall
be procted with granules.

C.R.Narayana Rao
Architects &Engineers 47 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

c) Providing and laying solid block 150mm thick using


cement mortar 1:3 with 75mm thick RC band @ every 1m
intervals with nominal reinforcements of 3 Nos of 8mm dia,
over the APP membrane as directed.

d) Providing, supplying, mixing, laying cement plaster 15


mm thick with cement mortar 1:4 mixed with approved water
proofing compound like CICO NO:1 or equivalent
conforming to IS at the rate specified by the manufacturer
over the coated surface of operation specified in point no.
(a) above.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 17000
plants, mixing device and gauge, shuttering, Nozzles etc.
complete as per manufacturer's specification and as
directed.

6.04 Treatment on Toilet floor slab, junctions of floor slab & wall
and side walls in toilets internal surfaces etc. covering the
following sequence of operation:

a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)

b) Providing, supplying, mixing, applying two coats of ready


to use two component Acrylic polymer modified cement
based, flexible, water proofing slurry like TAPECRETE or
approved equivalent to a thickness of 2 mm over the
plastered surface of operation above.

c) Providing, supplying, mixing, laying cement plaster 15


mm thick with cement mortar 1:4 mixed with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth below finished floor level.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 5500
plants, mixing device and gauge, shuttering, etc. complete
as per manufacturer's specification and as directed.

C.R.Narayana Rao
Architects &Engineers 48 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.05 Supplying and filling for sunken slab area with brickbat coba
using half bricks/ full bricks as per specification by adding
CICO NO:1 or approved equivalent admixture at the
specified in the manufacture's specification after entire
completion of laying pipes, sanitary fittings etc. Rate shall
Cum 2050
include for preparation of surface, protecting the laid pipes
and sanitary fittings, finishing the surface smooth to receive
the top coat of water proofing application etc. complete and
all as directed.

6.06 Treatment to top of brickbat coba in sunken slab covering


the following sequence of operations :

a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)

b) Providing, supplying, mixing, applying 2 coats of ready to


use 2 component acrylic polymer modified cement based,
flexible, water proofing slurry like TAPECRETE or approved
equivalent to a thickness of 2 mm over the plastered
surface of operation (a) above including preparation of
surface, dewatering, finishing, curing etc. all complete as
per manufacturer's specification and as directed.

c) Providing, supplying, mixing, laying cement plaster 15


mm thick with cement mortar 1:4 mixed with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth below finished floor level.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 4500
plants, mixing device and gauge, shuttering, etc. complete
as per manufacturer's specification and as directed.

6.07 Water proofing treatment over RCC roof slab laid to slope in
terrace and gutter slab covering the following sequence of
operation and specifications:
a) The roof slab laid in slope / gutter slab shall be
thoroughly cleaned by removing the debris and dust, to
receive the water proofing treatment.

C.R.Narayana Rao
Architects &Engineers 49 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

b) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)

c) Applying 2 coats of acrylic polymer modified cement


based, flexible water proofing slurry like TAPECRETE or
approved equivalent make to a thickness of 2mm and cured
for 7 days and as per manufacturer's specification.

d) Supplying, providing and applying water proofing


treatment with Membrane type water proofing methods
using polymer modified Bituminous membrane of CICO
shield/ Build Wrap/ Deboer or approved equivalent make.
The Atactic Poly-Propylene (APP-4mm th)membrane
having UV resistant, ground chemical resistant, high melting
point more than 110 deg. C, flexible and elastic with high
adhesive strength. The membrane shall be reinforced with
non woven polyester reinforcement of minimum of 180
g/sqm and reinforced including coating with compatible
primer of Bituminous base and torch application with
overlap of 100 mm wherever required. The reinforcement
provided shall be able to withstand the traffic flow density
during & after construction and shall carry a minimum
guarantee period of 10 years. Cost to include applying the
primer and torching the entire surface and also
prefabricated overlap at ends. The membrane surface shall
be protected with granules.

e) Providing, supplying & laying extruded polystyrene rigid


foam panel of size600 x 1200mm-75mm thick of formula
R.Metric-FM 50 having a density of 24 kg/cum and
compressive strength not less than 250 kpa of ownes
corning or approved equivalent make having exeptional
mechanical properties like resistance to the diffusion of
water vapour, resistance to water absorption, uniform
density distribution, dimensional stability, very high
compressive strength, aging resistance and also immunity
against insects, pets, bacteria, rodent attacks and micro
organisms etc., for over deck insulation including necessary
skin shiplap joint,anchores,adhesives, primers etc., as
required for proper fixing etc., complete all as per the
manufacturers specifications & consultants approval. The
extruded polystyrene panel has closed sealed cells
structure linked to one another is produced by a contineous,
fully automated extrusion process in accordance with
international specification and standard etc. all complete.

f) Laying fibre glass cloth over the extruded polystyrene


rigid foam panel.

C.R.Narayana Rao
Architects &Engineers 50 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

g) A layer of 20 mm thick cement mortar 1:4 admixed with


CICO NO - 1 (normal setting integral water proofing
compound) or other approved equivalent make compound
shall be spread over the operation specified in point (f)
above and laying brickbat coba over the surface 40mm
thickness at drain point and required thickness at ridge and
the top surface of the brickbat coba shall be plastered with
cement mortar 1:4, 20 mm thick admixed with CICO NO:1
@ 2% by the weight of cement and add RECRON 3S 225
per bag of cement and draw false line of 300 mm X 300 mm
over the finished surface. (The rate shall be quoted for an
average thickness of 110 mm).

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface,dewatering, finishing, curing, scaffolding, supply
and adding water proofing chemicals at the specified
proportion as per manufacturer's specifications, all
materials, wastages, conveyance, tools and plants, mixing Sqm 18950
device and gauge, shuttering and also include for
conducting leakage test at terrace by storing water on the
terrace for about 25 mm depth continuously for a period of 7
days etc.complete, as directed.

6.08 Extra rate over and above item no (6.07 g) above, for
Providing and laying brickbat coba using well burnt brick
bats set in cement mortar 1:3 by adding CICO no.1or Cum 1000
approved equivalent water proofing compound including
curing etc complete as directed

Total C/o.to Summary of 3 A in Rs.

7.00 MISCELLANEOUS WORKS

7.01 Providing and fixing in position single component, hydro


swelling bars made up of flexible polymer composites at
construction joints of retaining walls and water retaining
structures and wherever specified with proper overlaps at
joints of approved makes as per consultants approval

a Syncoflex make (25 x 25) Rmt 150

b Masterflex 610 of BASF make of size 10mm x10mm Rmt 3000


7.02 a Providing , placing and fixing in position 25mm thick PVC
board of lower density of supreme make -CAPCELL HD100
of 100 kg/cum density at all expansion joints and separation Sqm 2700
joints at all levels and wherever specified to the required
sizes, shapes, etc., complete.
b Same as above but with TRI BOARD HD 100 of 25mmth at
Expansion joints Sqm Qro

C.R.Narayana Rao
Architects &Engineers 51 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

7.03 Providing and fixing PVC (6 Kg/sqcm class) pipe of


specified dia below and approved make as rain water down
take pipe with all specials, accessories and joints with
solvent cement solution according to manufacturers
specification.

a 40 mm dia. Rmt 25

b 50 mm dia. Rmt 25

c 75 mm dia Rmt 25

d 110 mm dia Rmt 25

f 200 mm dia Rmt 3200


7.04 Supply and laying custom built (Pre. Fabricated) PVC
floor trap to drain out the water from condensing unit in
AHU room made out of 110 mm dia. PVC - 6 Kg/sq.cm
class pipe with bottom end sealed by PVC sheet 10 gauge
with single inlet and outlet from 40 mm dia. to 90 mm dia.
fixing to a perfect level with using cement concrete 1:3:6
mix using 20 mm size coarse graded aggregate and the Each 25
rate shall include to provide 150 x 150 mm size stainless
steel grating with frame alround, making holes in walls,
restoring damaged portions to their original conditions using
cement and required materials, testing and leak proof joints
etc. complete and all as directed.

7.05 Supplying and laying underdeck insulation using Aluminium


foil faced on one side resin bonded fibre glass wool of
density 32 kg/cum and K value not less than 0.031
kcal/Mtr/hr/Deg at 10 deg C and 50mm thickness. Rate
shall include fixing the wool in a grid ceiling comprising of
20 gauge unequal C channels at 600mm centres on one
direction and fastened to ceiling using anchor fastners,
Sqm 18950
applying two coats of bitumen at the rate of 1.5 kg / sqm on
the ceiling surface, and struck the insulation to the ceiling
with staggered joints and the entire surface of the insulation
shall be tyed with 25 gauge - 19 mm GI wire netting and
tied with G.I annealed wire - 18 gauge, etc complete and as
directed.

7.06 Supplying and fixing G.I.Puddle Flanges of various dia and


size made out of G.I with screwed ends, cap and plates for
embedment in concrete as necessary with suitable
accessories, consumables welding accessories including
placing in position, grouting, making necessary provision in
the centering & shuttering etc, including one coat of zinc
rich primer complete and as directed.

A Between 250 mm to 500 mm long.


I 50 mm to 100 mm dia Each 10
ii. 100 mm to 200 mm dia Each 10
iii. 200 mm to 300 mm dia Each 10
B Between 500 mm to 1000 mm long.

C.R.Narayana Rao
Architects &Engineers 52 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

I 50 mm to 100 mm dia Each 5


ii. 100 mm to 200 mm dia Each 5
iii. 200 mm to 300 mm dia Each 5
C Between 1000 mm to 1500 mm long.
I 50 mm to 100 mm dia Each 5
ii. 100 mm to 200 mm dia Each 5
iii. 200 mm to 300 mm dia Each 5
7.07 Making hole for rebar in concrete / masonry surface to any
dia and depth as required @ site by using HILTI make
driller with HY150 chemical compound for inserting the
reinforcement after drilling and air jet. Cleaning etc
complete, at any level, etc complete. Rate shall include for
all charges and preparation of surface, cutting of
reinforcement cleaning the surface, staging, scaffolding and
working platform, application of necessary chemical / foil as
per manufactures specification with necessary tools and
equipments, water and power, removal of debris from the
site, tax component etc complete, as directed.

a. 8 / 10 MM Dia - Rebar
I 12 / 14 mm dia & 120 Depth Each 25
ii. 12 / 14 mm dia & 140 Depth Each 25
iii. 12 / 14 mm dia & 150 Depth Each 25
iv. 12 / 14 mm dia & 160 Depth Each 25
v. 12 / 14 mm dia & 200 Depth Each 25
b. 12 MM Dia Rebar
I. 16 mm dia & 150 Depth Each 25
ii. 16 mm dia & 160 Depth Each 25
iii. 16 mm dia & 200 Depth Each 25
iv. 16 mm dia & 210 Depth Each 25
v. 16 mm dia & 220 Depth Each 25
c. 20 MM Dia Rebar
I. 28mm dia & 200mm Depth Each 25
ii. 28mm dia & 210mm Depth Each 25
iii. 28mm dia & 220mm Depth Each 25
iv. 28mm dia & 250mm Depth Each 25
v. 28mm dia & 280mm Depth Each 25
d. 25 mm dia Rebar
I. 30mm dia & 200mm Depth Each 25
ii. 30mm dia & 210mm Depth Each 25
iii. 30mm dia & 220mm Depth Each 25

C.R.Narayana Rao
Architects &Engineers 53 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

iv. 30mm dia & 250mm Depth Each 25


v. 30mm dia & 280mm Depth Each 25
e. 32 mm dia Rebar
I. 35mm dia & 200mm Depth Each 25
ii. 35mm dia & 210mm Depth Each 25
iii. 35mm dia & 220mm Depth Each 25
iv. 35mm dia & 250mm Depth Each 25
v. 35mm dia & 280mm Depth Each 25
7.08 Providing drilling and driving of various Dia & Shape Anchor
rods / Anchor fastener of HILTI make or approved
equivalent including all other consumables like chemicals,
foils, Grouting materials using HILTI make machinery, tools
& plants, all accessories etc complete and as directed.

I HST M 8/10 - 75 mm long. Each 25


ii HST M 10/30 - 110 mm long. Each 25
iii HST M 16/125 - 140 mm long. Each 25
iv HVU M 12x110 with HAS-E M 12/110/28 - 160mm long. Each 25
v. HVU M 16x125 with HAS-E M 16/125/38 - 190mm long. Each 25
v HVU M 20x170 with HAS-E M 20/170/48 - 240mm long. Each 25
vi HVU M 24x210 with HAS-E M 24/210/54 - 290mm long. Each 25
7.09 Making Core Cutting in slabs / beams / retaining walls and
any other R.C members to any dia & depth by using 'HILTI'
make diamond drilling machine with tolerance for any type
of inserts, anchor fasteners etc. Rate shall include for all
charge, preparation of surface, cutting of reinforcement,
cleaning the surface, staging, scaffolding application of
necessary chemical / foil (HAV) as per manufactures
specification with necessary tools and equipments water
and power, removal of debris from the site, staging
scaffolding etc complete, as directed.
a 75 to 100 mm dia to the following depth:
I. 150 mm Depth Each 10
ii. 200 mm Depth Each 10
iii. 250 mm Depth Each 10
iv. 300 mm Depth Each 10
b 100 to 150 mm dia to the following depth:
I. 150 mm Depth Each 10
ii. 200 mm Depth Each 10
iii. 250 mm Depth Each 10
iv. 300 mm Depth Each 10

C.R.Narayana Rao
Architects &Engineers 54 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

c 150 to 225 mm dia to the following depth:


I. 150 mm Depth Each 10
ii. 200 mm Depth Each 10
iii. 250 mm Depth Each 10
iv. 300 mm Depth Each 10
d 225 to 300 mm dia to the following depth:
I. 150 mm Depth Each 10
ii. 200 mm Depth Each 10
iii. 250 mm Depth Each 10
iv. 300 mm Depth Each 10
7.10 Supplying and fixing poly-propelene rungs of 20 mm square
bar of size 263 x 165 mm for access way including
anchorage in walls to a minimum depth of 100 mm with C.C
Each 500
1:2:4 etc. complete and as directed.( Duct & Over Head
Tank)

7.11 Supplying and fixing 40mm dia. and 150mm or more long
G.I. pipe spouts in sun shades including painting two coats
of first quality synthetic enamel paint of approved make
and tint over one coat of primer all as per specification and Each 50
as directed.

7.12 Supplying and fixing Heavy duty CI manhole cover and


frame of " NECO" make,cover weighing not lessthan the
following and being a size of 600 x 600 mm for overhead
tank including painting with two coats of anticorrosive paint
over a coat of primer etc. Rate shall include providing and
fixing locking arrangements, fixing the Man-hole cover,
grouting the anchors with C.C 1:2:4 as per specification
and as directed.

a. Weight Not less than 250 Kg. Each 15


b. Weight Not less than 160 Kg. Each 15
c Weight Not less than 110 Kg. Each 15
d Weight Not less than 50 Kg. Each 25
7.13 Supplying and installing MS fabricated gratings for storm
water drains/ ramp drains/ catch basins using ISA
50x50x6mm angles for outer frames and MS flats of 40x6
@ 50mm c/c both ways as per detailed drawings. The cost kg 750
to include Zincalumion primer and two coats of
enamel/zincrome paint, etc., complete

7.14 Providing, and Fixing of required dia.pipe sleeves of


approved makes as directed by the engineer in charge .cost
to include identification of positions,placing and tying with
reinforcement using MS hold fasts,tie rods,sealing of ends
with necessary formwork, staging, tools, etc., complete

C.R.Narayana Rao
Architects &Engineers 55 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

i 75mm Dia No. 10

ii 100mm Dia No. 10

iii 150mm Dia No. 10

iv 200mm Dia No. 10

v 250mm Dia No. 10


7.15 Providing and fixing in position Laminated Neoprene
bearing pad confirms to IRC:83(Part II) 1987 of shore
hardness 60 and Steel laminates of 3mm thickwith equal
thickness elastomer in between at all junctions/levels of
beams wherever specified by Consulting Engineers. Cost to
include 20 mm dia MS bar of 100 mm length each side
welded to the steel laminate,MS pipe sleeve of 25 mm dia
with a cap to cover the rod on one side,necessary
arrangements for embedding in concrete to the required
line,level etc,complete

a 100 mm X 100 mm X 40 mm No. 100


7.16 Providing and sealing the expansion joints with proprietory
based joint sealing systems from M/s. Vexcolt International
or equivalent. Necessary backer rod, Aluminium/S.S
extrusions, sealants if required as per the site
Condition,Anchor bolts tapes, cappings, gaskets, etc.,
complete as per approved details/ drawings. Cost to include
drilling and fixing of extrusions using heavy duty anchor
bolts, and sealing the joints capable of withstanding
repeated extensions, compressions, vibrations and cyclic
movement wothout lot of adhesion ans resist deterioration
by weathering, sunlight, ozone, water, salt water, oil, fuels,
acids and most of the commonly used acids, etc., complete
within 50% movement capacity.

cost to include cleaning concrete surface, making the


edges sharp by special sealants (cement and silica sand) or
by grinding, filling the gap with Tri- board (which will be paid
seperately in relevant item) applying 2 part epoxy bonding
agent, pre heating and filling the gap the with react series
joint material as per the specifications of the manufacturer
as approved by the Architect, filling the gap at slab with
polyurethane sealants or PVC membrane of thickness not
less than 1.2mm for water tightness etc.

a React 300 seriesof style 300-A01-050 for Floor to Floor


joints for 50mm joint width. Rmt 1855

b. React 300 seriesof style 300-A02-050 for Floor to


Wall/Corner joints for 50mm joint width. Rmt 500

c React 300 seriesof style 300-A07-050 or React 600 series


of style 651-A07-050 for External Wall to Wall or Column to
Rmt 1340
Column joints for 50mm joint width.

C.R.Narayana Rao
Architects &Engineers 56 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

d React 300 seriesof style 300-A09-050 or React 600 series


of style 651-A09-050 for External Wall to Corner joints for
Rmt 500
50mm joint width.

e. React 800 seriesof style 811-A07-050 for Internal Wall to


Wall or Column to Column or Ceiling to Ceiling joints for Rmt 500
50mm joint width.
f React 800 seriesof style 811-A09-050 for Internal Wall to
Corner or Ceiling to Wall joints for 50mm joint width. Rmt 450

g React 400 seriesof style 405-A01-050 for Floor to Floor


joints for 50mm joint width. Rmt 1875

h React 400 seriesof style 405-A02-050 for Floor to Wall


joints for 50mm joint width. Rmt 250

i React 600 seriesof style 661-A01-050 for Roof to Roof


joints for 50mm joint width. Rmt 400

j React 600 seriesof style 661-A02-050 for Roof to Wall


joints for 50mm joint width. Rmt 75

7.17 Providing and laying Hemalite / Vermiculite concrete 1:3 (1


part of cement & 3 part of Hemalite / Vermiculite aggregate)
having higher compressive strength and highest fire
resistance with thermal / acoustic insulation properties, anti-
corrosion, anti-condensation, etc of required proportion to
get the desired density, mixing, transportation, placing,
compacting and finishing to the required level with cum 50
necessary side supports, equipments, etc complete for infill
wherever required including laying layers as directed
including form work wherever necessary and well
compacted etc. all complete, as directed. (For ducts)

7.18 a Fire protection for Communication shafts and Security cable


shafts:: Providing and installing system of mouldable Putty
and fire rated mineral fibre sheet to seal construction gaps,
cables including fiber optic inner duct and cable, insulated
pipe electrical conduits, metal pipes, penetrations against
air draft, smoke, noxious gas and flame propagation. The
sheet shall be cut to allow for cable and conduit to pass
through and the gaps therein shall be filled with the putty.
The product shall be intumescent elastomer. Under normal Sqm 200
environmental conditions, the material shall be non-
corrosive to metal and compatible with synthetic cable
jackets. When exposed to flame or heat the putty shall be
capable of expanding and sealing any gaps caused due to
the fire conditions and the sheet will form the barrier in the
rest of the opening. Required fire rating is 2 hours.
Thickness of sheet may vary based on propritary systems.

C.R.Narayana Rao
Architects &Engineers 57 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

b. Fire protection for Electrical shafts: Providing and installing


intumescent technology Caulk material and fire rated
mineral fibre sheets for sealing construction blank openings
and penetrating items against the passage of flame noxious
gas, smoke and water. The mineral fibre sheet shall be the
primary barrier and the caulk material will be used to fill the
gaps around the openings made to allow for the passage of Sqm 400
the cable trays, conduits and any other related services like
rising mains etc. The product should restore fire rated
construction to original integrity. It shall be compatible for
penetrating sealing. Required fire rating is 2 hours.

c Fire protection for Fire hydrant shafts: Providing and


installing fire rated mineral fibre sheet and Endothermic
technology Caulk material to be used for sealing
construction blank openings and penetrating items against
the passage of flame noxious gas, smoke and water. The
mineral fibre sheet shall be cut to allow for the passage of
fire hydrant and sprinkler pipes and the annualar space
sqm 600
around that shall be sealed with the caulk to seal all gaps.
The product should restore fire rated construction to original
integrity. The mineral fibre sheet shall be the primary barrier
and the caulk material will seal against passage of smoke,
noxious gas etc. Required fire rating is 2 hours.

d Fire protection for ACMV shafts/ wall openings: Providng


and installing Intumescent technology Caulk material is
used for sealing construction blank openings and
penetrating items against the passage of flame noxious
gas, smoke and water. Providing and installing intumescent
technology Caulk material and fire rated mineral fibre
sheets for sealing construction blank openings and
penetrating items against the passage of flame noxious
gas, smoke and water. The mineral fibre sheet shall be the Sqm 900
primary barrier and the caulk material will be used to fill the
gaps around the openings made to allow for the passage of
the cable trays, conduits and any other related services like
rising mains etc. The product should restore fire rated
construction to original integrity. It shall be compatible for
penetrating sealing. Required fire rating is 2 hours.

C.R.Narayana Rao
Architects &Engineers 58 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

e. Fire protection for Plumbing&Sanitary shafts: Providng and


applying Fire barrier Mortar for sealing penetrations in the
wall and floor assemblies. Fire barrier mortar shall be a
lightweight cementitious product. The product should have
fire rating and capable of upto 2 hours rating. The material
should not contain Asbestos or Man made mineral fibers.
The product shall have characteristics of self-leveling and
should not sag. It should accommodate re-entry ability Sqm 500
without the use of power tools. This will be applied on a
frame work installed in MS by main contractor. The
framework will be structural steel frame as in the drawing
and with metal decking sheet so as to provide the required
structural stability for the mortar will providing sufficient
support to allow for access of maintenence crew.

f Fire protection for wall entry from service areas into the
open office areas or into adjacent rooms : Providing and
applying moldable Putty to seal construction gaps between
walls and in the junction of wall and partition or between
partitions as also in the concentric spaces between the
vertical surfaces and service inlets or outlets such as ducts,
conduits, cable trays, pipes, dampers, grilles, actuators and
any peneration for return air etc. against air draft, smoke,
noxious gas and flame propagation. The product shall be
intumescent elastomer. Under normal environmental Sqm 100
conditions, the material shall be non-corrosive to metal and
compatible with synthetic cable jackets. When exposed to
flame or heat it shall be capable of expanding and sealing
any gaps caused due to the fire conditions. The required
fire rating is 2 hours and the application is to be done
around the gaps between the masonry and frame or frame
and service frames.

g Wall openings protection with fire rated mineral fibre


sheets and sealer/ caulk/ putty : Providing and intalling
Fire rated sealer system made from High Density mineral
wool. The mineral wool shall be coated with fire rated
Sealer which will remain in place during fire and form a
barrier against it for upto 2 hours. The small gaps if any
between the base building masonry openings and the
mineral fibre sheets shall be filled with caulk or putty so as
to seal all gaps against the passage of fumes, smoke etc.
Tests shall be carried out as per UL/ ASTM or BS-476: Part-
20 1987.The maximum size wall opening is 1 sqm ( 1m x
1m) and if the opening is greater than this it should either
be reduced using the same construction material as base
wall. No additional support is required to the barrier system.

C.R.Narayana Rao
Architects &Engineers 59 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

The rate shall include a two hour rated system shall consist
of 2 x 50mm x 120kg coated (Each on one face) mineral
fibre batts. Each batt is placed in the wall opening with the
coated face exposed and sitting flush with the face of the
wall. Any fire sealer applied shall be to either cover all gaps Sqm 100
or to an extent of 100mm beyond the point of penetration of
the services conduits etc. For all openings around cable
entry, grille, tray , duct etc in walls

7.19 Dismantling of Plain Cement Concrete concrete work to


any depth and width, at all levels below & above Ground
Level of any shape, removal of debris, disposing the same
away from the site, loading and unloading, making the
surface good etc. complete. Rate shall include for
dismantling of Plain Cement Concrete by manually /
mechanical means with necessary tools and plants,
Cum 10
scaffolding, water and power charges, cleaning the surface,
preparation of surface etc. Rate shall include for stacking
the serviceable materials and disposing the unserviceable
materials/debris away from the site by mechanical means
including loading, unloading, clearing the site etc. complete,
as directed.

7.20 Dismantling of Reinforced Cement Concrete work to any


depth and width, at all levels below & above Ground Level
of any shape, removal of debris, disposing the same away
from the site, loading and unloading, making the surface
good etc. complete. Rate shall include for cutting of rods to
any dia, dismantling of Reinforced Cement Concrete by
manually / mechanical means with necessary tools and
Cum 15
plants, scaffolding, water and power charges, cleaning the
surface, preparation of surface etc. Rate shall include for
stacking the serviceable materials and disposing the
unserviceable materials/debris away from the site by
mechanical means including loading, unloading, clearing
the site etc. complete, as directed.

7.21 Dismantling of Brick Work / Block Work including


plastering/pointing to any depth and width, at all levels
below & above Ground Level including removal of debris,
disposing the same away from the site, loading and
unloading, making the surface good etc. complete. Rate
shall include for dismantling of Brick Work / Block Work
including plastring/pointing, removal of debris by manual /
mechanical means with necessary tools and plants, Cum 10
scaffolding, water and power charges, cleaning the surface,
preparation of surface. Rate shall include for stacking the
serviceable materials and disposing the unserviceable
materials/debris away from the site by mechanical means
including loading, unloading clearing the site etc. complete
as directed.

C.R.Narayana Rao
Architects &Engineers 60 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

7.22 Providing and laying in position the RCC humepipes(NP2)


of approved quality and make including collars,.necessary
Excavation, PCC 1:2:4 supports, Sand cushion of 150mm
on all sides, Refilling with earth, Compaction and making
good the level, alignment etc.,complete

a 450 mm dia
Rmt 100

b. 300 mm dia
Rmt 200

c 150mm dia
Rmt 250

Total C/o.to Summary of 3 A in Rs.

C.R.Narayana Rao
Architects &Engineers 61 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

SECTION 3 B - MAIN BUILDING - CIVIL FINISHES

1.00 MASONRY WORKS


1.01 Providing and constructing brick work with best quality well
chamber burnt moulded bricks with minimum compressive
strength of 50 Kg per Sq.cm. in cement mortar 1:5 for Cum 50
foundations and basements etc. complete and as directed.

1.02 Providing and constructing brick work with best quality well
chamber burnt moulded bricks with minimum compressive
strength of 50 Kg per Sq.cm. in cement mortar 1:5 for Cum 50
superstructure at all levels complete and as directed.

1.03 Providing and constructing 115 mm thick masonry wall at all


levels with approved best quality well chamber burnt
moulded bricks with minimum compressive strength of 50
Kg/Sq.cm in cement mortar 1:4 with M20 reinforced cement
concrete binders - 80 mm thick laid horizontally to the full
length of the wall at 1000 mm ctc using coarse graded
aggregate of 12 mm and downsize and reinforced with 8
mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm dia for Sqm 100
stirrups at 200mm centres using Fe 500 grade steel. Rate
shall include for cost of reinforcements and tying in postion
using binding wire made out of 16 gauge GI annealed or 18
gauge SS, form work, scaffolding, raking out joints, curing
etc complete and as directed.

1.04 Providing and constructing cement concrete solid block


masonry work at all levels in cement mortar 1:3 using
standard size of 400 x 200 mm of solid cement concrete
blocks of thickness and compressive strength of block as
given below including all scaffolding, staging, curing, all lifts
etc. complete and as directed as per the IS relevant
standards. Concrete blocks manufactured under strict
quality control conditions using modern rugged block
casting and stripping machine with the latest moulding
techniques etc. only shall be used.
a M - 10 Grade of Solid block work for the following thickness
( for external walls especially for supporting the ACP and
such any other cladding works )

i Solid block wall of 200 mm thick


Sqm 4100

b M - 5.5 Grade of Solid block work for the following


thickness ( for internal walls )

i Solid block wall of 200 mm thick


Sqm 37325

C.R.Narayana Rao
Architects &Engineers 62 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

ii Solid block wall of 150 mm thick


Sqm 2450

iii Solid block wall of 100mm thick


Sqm 500

1.05 Providing and constructing cement concrete Hollow block


masonry work at all levels, in cement mortar 1:3 using
standard size of 400 x 200 mm of hollow cement concrete
blocks of thickness as given below, with minimum
compressive strength of 3.5 N/Sq.mm. including all
scaffolding, staging, curing, all lifts etc. complete and as
directed. Concrete blocks manufactured under strict quality
control conditions using modern rugged block casting and
stripping machine with the latest moulding techniques etc.
only shall be used. Rate shall include for grouting of cores
in blocks to complete course for fixing of frames and all
joinery works etc complete, as directed.

I Hollow block wall of 200 mm thick


Sqm 100

ii Hollow block wall of 150 mm thick


Sqm 100

iii Hollow block wall of 100 mm thick


Sqm 100

1.06 Extra rate over & above Solid / Hollow Masonry wall for
providing R.C.Binders of 80 mm thick laid horizontally to
the full length of the wall at 1000 mm ctc using coarse
graded aggregate of 12 mm and downsize and reinforced
with 8 mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm
dia for stirrups at 200mm centres using Fe-500 grade steel,
including cost of reinforcements and tying in postion using
binding wire made out of 16 gauge GI annealed or 18
gauge SS, form work, scaffolding, all labour, hire and fuel
charges for all tools and plants employed and all other
incidental charges etc. all complete, as directed. ( For both
internal and extrernal walls )

i Solid block wall of 150mm thick


Sqm 2450

ii Solid block wall of 100mm thick


Sqm 500

1.07 Random rubble masonry in C.M. 1:5 for foundation and


basement including necessary bond stones with
simultaneous flush pointing above ground level with the Cum 100
same mortar and including curing etc complete as directed].

Total C/o.to Summary of 3 B in Rs.

C.R.Narayana Rao
Architects &Engineers 63 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.00 FLOORING AND DADOOING WORKS

2.01 Providing and laying in panels not more than 20 sqm. in


plan granolithic flooring with cement concrete 1:1.5:3 by
using coarse graded aggregate of 6 to 12 mm size laid
monolithic with floor concrete and finished smooth with
power trowel including preparation of concrete surface and
form work. The screed strips shall be fixed on the base
concrete with 6 mm thick solid aluminium or other metals
strips for effective separation of panels not exceeding 20
sqm. in plan etc. complete as per Specifications and as
directed. Unevenness in floor finish shall not exceed + 2mm
in one square metre area.Rate to include lead , lift at all
levels, pumping, placing, necessary formwork, curing etc.,
complete

a 65 mm thick.
Sqm 62113

b 50 mm thick.
Sqm 2850

c 40 mm thick.
Sqm 200

d 25 mm thick.
Sqm 100

e Extra rate over & above item no (a ) , for providing and


laying self levelling three component pigmented epoxy
jointless floor topping " Shalideck - SL " -750 microns and
the application at the rate specified by Manufacturer STP ltd
including laying over granolithic flooring in panels not more
Sqm 1900
than 20 sqm. in plan as per manufacturer's specification,
including preparation of surface, application, wastage,
equipment, tools and plants, work at all levels etc. complete
as directed.- AHU & Services.

f Extra rate over & above item no (a) , for providing and
laying self levelling three component pigmented epoxy
jointless floor topping " Shaliscreed - AS " -1000 microns
and the application at the rate specified by Manufacturer
STP Ltd including laying over granolithic flooring in panels
not more than 20 sqm. in plan as per manufacturer's Sqm 850
specification, including preparation of surface, application,
wastage, equipment, tools and plants, work at all levels etc.
complete as directed.-Electrical Rooms.

C.R.Narayana Rao
Architects &Engineers 64 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.02 Providing,supplying and laying,finishing M20 grade ready


mixed controlled concrete for non slippery, Vaccum
dewatered flooring including cleaning, trimming, watering
the surface, laying in strips to required levels, power
trovelling, smoothening curing etc., making 15mm x 10mm
expansion / control joints at intervals, sealing the joints with Cum 6225
polyeurathane/approved sealants, etc., complete to the
required slope, formation, finish. (VD operation shall be
paid separately)

2.03 Providing vacuum de-watered flooring operation consisting


of providing side shuttering with MS channels, angles to the
required levels, Vibrating the concrete by using screed
vibrator, de-watering using vacuum pumps by suction
method and finishing the top surface to required level and Sqm 62250
grade using skim floaters/discs/power trowels. Covering
the finished concrete surface with 200 micron thick
polythene sheet and curing etc., complete.

2.04 Extra over for providing and mixing Graded fibrillated 100%
virgin poly propelene fibres in concrete at the rate of 0.90
kg/cum as per manufacturers specifications. Fibremesh MD
Supplied by M/s Millenium buiding systems or equivalent.

a Fibremesh MD Cum 50
b Recron 3S by Reliance Cum 6225
c Cemfil HD Cum 25
2.05 Extra over for providing and mixing READY MIX DRY
SHAKE ABRASION RESISTANT FLOOR HARDENER of
non - metallic monolithic surface floor hardening compound
CICO FLORTOP-E RTU from CICO or TecTM Floor Z from
TECHNY CHEMY make over the laid concrete at the rate of Sqm 62113
minimum 5.0kg/m2 using power trowelling for quick and
making smooth levelled surface etc.,all as per
manufacturers' specifications.

C.R.Narayana Rao
Architects &Engineers 65 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.06 Providing flooring with Premium quality Johnson


Marbonite or approved equivalent make vitrified floor tiles
(seamless)confirming to ISO 13006/EN 176 Group BIa
with tech.specification as Mohs scratch hardness greater
than 6,Water Absorption of 0.06%, Modulus of Rupture
greater than 27 N/mm, Deep Abrasion resistant less than
204 mm cube, Surface flatness, Straightness of sides
0.25%, thickness 5% of size of approved colour and
size & thick as specified below, set in Laticrete adhesive L
290 and pointing with Laticrete make Latapoxy SP 100 of
approved make, to matching colour shade as per
Manufacturer's Specification and as directed. Rate shall
include provision of PVC spacers of 3 mm with polymer
epoxy grout, wastages, for preparation of base surface,
cleaning, acid wash, and finished surface, protection with
Gypsum / Pop layer over Plastic sheet and removing the
same before handing over,work at all levels and as
directed.Rate shall be inclusive of forming pattern as shown
in dwg and wastages etc; complete.

I. Vitrified Tile - polished of approved Colour

Sqm 2000
a. Size : 1200 x 1200 mm

Sqm 1500
b Size : 600 x 600 mm - 9 mm thick.

Sqm 500
c Size : 400 x 400 mm - 7 mm thick.
2.07 Providing flooring with best quality approved colour granite
slab not less than 20 mm thick of size not less than 1200 x
900 mm / 900 x 600 / 600 x 600 mm or as directed,
machine cut and machine high pre-polished, set in C.M 1:4,
20 mm thick topped with white cement slurry (for surface
contact of the bottom of the granite slab) as per approved
pattern / design including finishing the joints with white
cement slurry, cutting, edge chamfering and polishing Sqm 1000
rough, medium, nice and acid wash and tin-oxide polish as
per manufacturer's Specification and as directed. Rate shall
include for preparation of base surface & finished the
surface, protection with gypsum / pop layer over plastic
sheet and removing the same before handing over, work at
all levels and as directed.

C.R.Narayana Rao
Architects &Engineers 66 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.08 Providing and fixing step risers and treads with approved
colour granite slab of thickness not less than 22 mm in
single piece for each step patterned as per drawing over a
bed of C.M 1:4, 20 mm thick, all edges machine cut,
machine polished including cutting, Flame the Granite for
the entire width of the steps (Entrance steps), as per
manufacturers specification and as directed. Rate shall Sqm 900
include for preparation of base surface, jointing with
matching cement slurry and finished surface protection with
gypsum / POP layer over plastic sheet and removing the
same before handing over, work at all levels etc complete,
all as directed.
2.09 Providing and fixing step treads with approved Kotah stone
slab of thickness not less than 22 mm in single piece for
each step rounded or patterned as per drawing over a bed
of C.M 1:4, 20 mm thick, all edges machine cut, machine
polished including cutting, chamfering and making groove
to the specified size in the edges( Staircase steps),edge
polishing to rough, medium, nice, acid wash and tin oxide
polishing as per manufacturers specification and as Sqm 1700
directed. Rate shall include for preparation of base surface,
jointing with matching cement slurry and finished surface
protection with gypsum / POP layer over plastic sheet and
removing the same before handing over, work at all levels
etc complete, all as directed.

2.10 Providing flooring with best quality approved Kotah stone


slab not less than 22 mm thick and the size of slab in
general not less than 600x600 mm, machine cut and
machine high pre-polished, set in C.M 1:4, 20 mm thick
topped with white cement slurry (for surface contact of the
bottom of the granite slab) as per approved pattern/design
by using irrespective of size and shape, including finishing
the joints with white cement slurry, cutting, edge chamfering
Sqm 1200
and polishing rough, medium, nice and acid wash and tin-
oxide polish as per manufacturer's Specification and as
directed.Rate shall include for preparation of base surface
& finished the surface, protection with gypsum/pop layer
over plastic sheet and removing the same before handing
over,work at all levels, as directed.

C.R.Narayana Rao
Architects &Engineers 67 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.11 Providing Dadooing with Premium quality Kajaria/


Johnson/Bell/ Somany make confirming to IS 13755 glazed
tile ranges, with scratch resistance of minimum 3 , Water
absorption greater than 10 % Deviation in length ,
Thickness of maximum +0.5%,Wedging warpage of
maximum +0.6%, Abrasion resistance IS 13630(part-
2),Bending strength of minimum 150 kg/cm2 and Thermal
shock resistant to 10 cycles etc., as per manufacture's
specification and sizes as listed below set in Laticrete
adhesive L 290 to a thickness of 6mm and jointing with
Latapoxy SP 100 of Laticrete make all as per
manufacturer's specification, at all levels and as directed.
Rate shall include for preparation surface, wastages,
smooth joint, cleaning and acid wash etc. complete and as
directed.

I Size 200x300mm/ 250 x 400mm/ 250 x 350mm-7 mm tk.


Sqm 4900
ii Size 200x300mm/ 250 x 400mm/ 250 x 350mm-7 mm tk.
Sqm 6050
iii Size - 200 x 200 x 7mm thick
Sqm 100
Iv Size - 200 x 300mm x 7mm thick
Sqm 50
2.12 Providing flooring with cement based button tile of
Duracrete (Shape - Reflections/Plazza/ Prima & cross
word), Ultra (Shape - Falcon) or Eurocon or unicorn (Shape -
Olympus) or or approved equivalent make, tile thick not less
than 20 mm of approved colour and shade, of approved
shape over a coat of C.M 1:4, 20 mm thick and jointed with
matching cement slurry including providing in proper slope Sqm 500
over the existing surface of grano flooring and all as
directed. Rate shall include for preparation of base surface
& finished the surface, protection with gypsum / pop layer
over plastic sheet and removing the same before handing
over,work at all levels and as directed.

Total C/o.to Summary of 3 B in Rs.

3.00 JOINERY WORKS

3.01 Providing and fixing of hollow metal fire rated steel door 2
Hour / 1 Hour rating confirming to IS 3614 or Equivalent BS
and General purpose steel door at all levels with frames
and with fully flush type shutter having 48 mm thick made
out of Pressed Galvanised steel sheet confirming to IS 277,
(Coating shall be GLP grade Z 120 microns coating) to any
type, Size, Shape with various opening policy and of
System Schroders or approved equivalent make, but in
general the door consists of the following and the quoted
rate shall include the following :

C.R.Narayana Rao
Architects &Engineers 68 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

a) Door Frame : Fabricated from galvanized steel sheet to


the profile and the thickness specified below :
i) Fire Door - 2 Hr rating : Double rebate profile of size 143
x 57 mm (+/- 0.3) with bending radius of 1.6 mm, using
galvanized steel sheet of 1.6 mm thick (16 Gauge).
ii) Fire Door - 1 Hr rating: Single rebate profile of size 100
x 57 mm (+/- 0.3) with bending radius of 1.4 mm, using
galvanized steel sheet of 1.20 mm thick (18 Gauge).
iii) General Purpose Door : Single rebate profile of size
100 x 57 mm (+/- 0.3) with bending radius of 1.4 mm, using
galvanized steel sheet of 1.20 mm thick (18 Gauge).

Frames shall be provided with the following :


i) Back plates - 3 mm thick on all jambs with provision for
anchor bolt fixing to wall openings.
ii) Hinge plates 3 mm thick pre-drilled to receive approved
type and make of hinges for screw mounted fixing.
iii) Factory finish-pre-punched cut outs to receive specified
type & make of hardware and iron mongery. All cut outs
including hinge plates, strike plates to have mortar guard
covers from inside to prevent cement, dust ingress into cut
outs at the time of grouting of the frame.
iv) Reinforcement pads for fixing of door closer, locks and
handles at appropriate location as per manufacturers
details.
v) Plug-in type rubber silencer not less than 2 mm dia shall
be provided on the strike jambs for single shutter frames
and on the head jambs for double shutter frames.
vi) Frames shall be in knock down form with butt joints for
bolted assembly at site or as per manufacturers
specification with out visible joints/welding marks in frames.

b) Door Shutter : Shutters should be press formed with


double skins to a total 48 mm thick hollow shutter with lock
seam joints at stile edges using galvanized steel sheet of
thickness specified below :
i) Fire Door - 2 Hour rating : 1.00 mm thick (16 Gauge).
ii) Fire Door - 1 Hour rating : 0.80 mm thick (19 Gauge).
iii) General Purpose Door : 0.80 mm thick (19 Gauge).

C.R.Narayana Rao
Architects &Engineers 69 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Shutters shall be provided with the following :


i) No visible screws or fasteners on either face and Internal
reinforcement shall be provided at top, bottom and stile
edges for desired fire rating.
ii) Factory prepared shutter with pre-punched cutouts and
reinforcement pads to receive the approved type and make
of Hardware and Iron mongery.
iii) Pre-drilled hinge plates with hinge guard covers and
shutters with locks to have concealed lock box with lock
fixing brackets with pre-tapped holes and screws.
iv) Reinforcement pad at appropriate location to receive the
locks, Door closer, Panic Bar, etc as per the approved type
and make of Hardware and all as per manufacturers design
and conforming to Standards.
v) Necessary provision / fixing arrangements shall be
provided in the shutter as well as in the frame to receive / fix
the Electro magnetic latch, Electro magnetic contact for
hooter with reinforcement pads and in such a way to
connect the same to the card access control system / IBMS.

c) Infil material: Honeycomb paper core as infill material


and to be bounded to the inner faces of the shutter or as
per Manufacturers specification. Door should have been
tested with Infill material proposed by the manufacturer and
the same should have been approved by CBRI / BFRC.

d) Finish: Surface of the frame and shutter shall be


cleaned suitably & thoroughly with solvents and as per
manufacturers specification. Apply Zinc etch primer coating
as shop coat to receive additional coat of primer and top
coats, apply stove zinc phosphate primer (35 microns DFT)
as additional coat and finish the surface neatly with thermo
setting polyurethane paint (35 microns DFT) of approved
colour and make.
e) Installation : The frame and shutter shall be installed in
position as per the methdology described in the Technical
specification with necessary accessaries, tools & Plants etc.

f) Grouting: Frame shall be pressure grouted with cement


slurry 1:3 ratio or filling the pre cast solid block core to the
frame profile as approved. The surface after grouting shall
be neatly cleaned and to be ensured that there is no
scratch in the door frames after grouting.Back fill the frame
through holes provided and insert plug in type nylon plugs
after cleaning the surface and to suit the frame finish and
colour.

C.R.Narayana Rao
Architects &Engineers 70 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

G) Hardwares :
i) Vision panel : Providing and fixing Borosilicate single
clear toughened glass of Pyron or approved equivalent
make to the thickness of 6 mm to with stand two hours fire
rating including making cutouts in the steel door & fixing in
position with spin turned rings. Rate shall include for
providing one side adhesive Glazing tape in the frame to
hold the vision panel glass in position and to ensure the
stability of the fixing. One vision panel shall be provided in
the active leaf of the Single / Double leaf shutter.
ii) Hinge : Providing and fixing Stainless steel satin finish
double ball bearing butt hinges with SS screws of size 100
x 75 x 3 mm thick - Model No. SS 551 B - class 8 / 9 from
Dorma or approved equivalent make suitably for Single /
Double leaf door. Stainless steel conforming to SS 316 L
grade to BS 7352 or BS EN 1935-2002. 4 Nos for Single
Leaf Shutter and 8 Nos for Double Leaf Shutter.
ii) Flush Bolt : Providing and fixing Stainless steel satin
finish consealed tower bolt with SS screws of approved
equivalent make for Double leaf door in the In - Active leaf.

H) Provision :
i) Provision / fixing arrangements to be made in the shutter
as well as in the frame to receive / fix the Hinges, Locks,
Electro magnetic latch, Electro magnetic contact for hooter
with reinforcement pads and in such a way to connect the
same to the card access control system / IBMS.
ii) Refer hardware schedule enclosed for the details of
Mortise sash lock, Mortise dead lock, Handles, Push plates
and Panic bar etc. Necessary provision shall be made in
the frame and shutter to receive and fix the hardwares.
iii) Supplying Master key for the doors either floor wise or
wing wise as per the Master key plan including supplying
Grand Master key for all the doors.

Note :
1. All the Materials and hardware specifications proposed
for door shall conform to the codes, technical specification
and preamble to the bills of quantities.
2. Quoted rate shall be deemed to have considered all the
items covered in the specification and drawings, whether
explicitly stated or not.

a Fire Rated Steel - 2 Hr Rating

i Double Leaf Door


Sqm 100

ii Single Leaf Door


Sqm 265

C.R.Narayana Rao
Architects &Engineers 71 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

b Fire Rated Steel - 1 Hr Rating

i Double Leaf Door


Sqm 215

ii Single Leaf Door


Sqm Qro

c General Series Steel Door

i Double Leaf Door


Sqm Qro

ii Single Leaf Door


Sqm 150

3.02 FIRE RATED STEEL DOOR HARDWARES

Extra rate over and above steel door items for providing and
fixing the following Hardwares in position in the doors
supplied with all necessary accessories etc complete and
as directed.
a Mortice Sash lock with lever handle on both sides with
internal thump turn and external key operation - Stainless
steel satin finish - 316 L grade of ST - 8100 with 752 lock
or Dorma or approved euivalent make with forend with Euro
profile cylinder Pc 93 with external key operation and
Each 150
Internal thump turn and strike plate of Dorma make and
the strike plate shall be provided to suit the type of door
specified. (ie.Single/Double leaf). Stainless steel shall
conform to BS. (AHU Room and Other Servises )

b Mortice dead lock - Stainless steel satin finish - 316 L


grade of Model.no. Dead bolt 778 lock with escutcheon
and euro profile full cylinder Pc 91 with both side key
provision and strike plate of Dorma make and the strike
Each 35
plate shall be provided to suit the type of door specified.
(ie.Single/Double leaf). Stainless steel shall conform to BS.
Electrical Room.

c Rim panic latch with outside entry function - Model No.


PHA 2100 (A) - Function with Lockable Lever on outside
with euro Profile Cylinder and external key & Lever
Handle (one side) operation PHT 3905 of Dorma make. Each 140
and to be fixed in active leaf of the single/double leaf door .-
Staircase and Exit Door

d Automatic door closer Model No.TS 92 cam action G


(Push/Pullside) or B (Push/Pull side) EN 2 to 4 of Dorma
make. (Door closer shall be provided to suit the type of door
opening / opening policy specified. Ie. Double / Single leaf Each 340
and Push / pull side) with all other accessories.(To use
Shutter width upto 1100 mm)

C.R.Narayana Rao
Architects &Engineers 72 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

e Pull Handle - D type of size and model as specified below


having - Stainless steel satin finish - 316 L grade of Dorma
make with SS screws / inside bolt fixing.

i Model.No. TGD1 450 22 S or approved equivalent


Each 10

ii Model.No.TGD1 300 22 S
Each 32

f Push plate of size 300 x 150 mm - 1.5 mm thick - Stainless


steel satin finish - 316 L grade of Model No.SP 006 A of
Dorma make or approved equivalent and with SS screws. Each 32

3.03 Providing and fixing 35mm thick flush door shutters (Kutty /
Diamond/Jackson's make) single leaf / Double leaf of solid
core of block board type bonded with phenol formaldehyde
synthetic resin thermo pressed with 8 mm thick teak wood
tongue & groove external lipping. The construction
procedure of the shutter should be as per IS 2202. The
shutter shall be shop prepared for taking mortice lock or
latches suitable lock block of wood may be provided for
fixing the hardware. The size of block, shall perfectly
correspond to the maximum size of lock, covered in IS
2209. All the four edges of the door shutter shall be
square. The shutter shall be free from twist or warp in its
plane and of required size etc. complete as directed.

i) Hardwares :
i) Hinge : Providing and fixing Stainless steel satin finish
double ball bearing butt hinges with SS screws of size 100
x 75 x 3 mm thick - Model No. SS 551 B - class 8 / 9 from
Dorma or approved equivalent make suitably for Single /
Double leaf door. Stainless steel conforming to SS 316 L
grade to BS 7352 or BS EN 1935-2002. 4 Nos for Single
Leaf Shutter and 8 Nos for Double Leaf Shutter.

ii) Provision :
i) Provision / fixing arrangements to be made in the shutter
as well as in the frame to receive / fix the Hinges, Locks,
Electro magnetic latch, Electro magnetic contact for hooter
with reinforcement pads and in such a way to connect the
same to the card access control system / IBMS.
ii) Refer hardware schedule enclosed for the details of
Mortise sash lock, Mortise dead lock, Handles, Push plates
and Panic bar etc. Necessary provision shall be made in
the frame and shutter to receive and fix the hardwares.
iii) Supplying Master key for the doors either floor wise or
wing wise as per the Master key plan including supplying
Grand Master key for all the doors.

C.R.Narayana Rao
Architects &Engineers 73 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Note :
1. All the Materials and hardware specifications proposed
for door shall conform to the codes, technical specification
and preamble to the bills of quantities.
2. Quoted rate shall be deemed to have considered all the
items covered in the specification and drawings, whether
explicitly stated or not.

Rate shall include for making provision to fix the approved


hardwares as specified in the tender drawing schedule as a
separate item etc. complete and as directed.
Rate shall include the following

a Single leaf Flush door.

I. Fully flush shutter with commercial ply on both sides


finished with 0.40 mm thick teak veneer and melamine
Sqm 255
polished as per manufacturers specification

ii. Fully flush shutter with commercial ply on both sides and
finished with 1.5mm thick laminate on both sides of
approved colour, make and shade. Sqm Qro

b. Double leaf Flush door.

I. Fully flush shutter with commercial ply on both sides


finished with 0.40 mm thick teak veneer and melamine
polished as per manufacturers specification. Sqm Qro

ii. Fully flush shutter with commercial ply on both sides and
finished with 1.5mm thick laminate on both sides of
approved colour, make and shade. Sqm Qro

3.04 Providing and fixing 32mm thick flush door shutters (Kutty /
Diamond/Jackson's make) single leaf / Double leaf of solid
core of block board type bonded with phenol formaldehyde
synthetic resin thermo pressed with 8 mm thick teak wood
tongue & groove external lipping. The construction
procedure of the shutter should be as per IS 2202. The
shutter shall be shop prepared for taking mortice lock or
latches suitable lock block of wood may be provided for
fixing the hardware. The size of block, shall perfectly
correspond to the maximum size of lock, covered in IS
2209. All the four edges of the door shutter shall be
square. The shutter shall be free from twist or warp in its
plane and of required size etc. complete as directed.

C.R.Narayana Rao
Architects &Engineers 74 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

i) Hardwares :
i) Hinge : Providing and fixing Stainless steel satin finish
double ball bearing butt hinges with SS screws of size 100
x 75 x 3 mm thick - Model No. SS 551 B - class 8 / 9 from
Dorma or approved equivalent make suitably for Single /
Double leaf door. Stainless steel conforming to SS 316 L
grade to BS 7352 or BS EN 1935-2002. 4 Nos for Single
Leaf Shutter and 8 Nos for Double Leaf Shutter.

ii) Provision :
i) Provision / fixing arrangements to be made in the shutter
as well as in the frame to receive / fix the Hinges, Locks,
Electro magnetic latch, Electro magnetic contact for hooter
with reinforcement pads and in such a way to connect the
same to the card access control system / IBMS.
ii) Refer hardware schedule enclosed for the details of
Mortise sash lock, Mortise dead lock, Handles, Push plates
and Panic bar etc. Necessary provision shall be made in
the frame and shutter to receive and fix the hardwares.
iii) Supplying Master key for the doors either floor wise or
wing wise as per the Master key plan including supplying
Grand Master key for all the doors.

Note :
1. All the Materials and hardware specifications proposed
for door shall conform to the codes, technical specification
and preamble to the bills of quantities.
2. Quoted rate shall be deemed to have considered all the
items covered in the specification and drawings, whether
explicitly stated or not.
Rate shall include for making provision to fix the approved
hardwares as specified in the tender drawing schedule as a
separate item etc. complete and as directed.
Rate shall include the following

Rate shall include necessary all approved hardwares as


specified in the tender drawings etc. complete and as
directed.

a. Single leaf Flush door. Fully flush shutter with commercial


ply on both sides and finished with 1.5mm thick laminate on
Sqm 750
both sides of approved colour, make and shade.

b. Double leaf Flush door - Fully flush shutter with


commercial ply on both sides and finished with 1.5mm thick
Sqm Qro
laminate on both sides of approved colour, make and
shade.

3.05 FLUSH DOOR HARDWARES

Extra rate over and above steel door items for providing and
fixing the following Hardwares in position in the doors
supplied with all necessary accessories etc complete and
as directed.

C.R.Narayana Rao
Architects &Engineers 75 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

a Mortice Sash lock with lever handle and internal thump


turn - Stainless steel satin finish - 316 L grade of ST 8100 -
lever handle on both sides with ST 7122 WC indicator with
775 lock or approved euivalent make with forend and strike Each 100
plate of Dorma make and the strike plate shall be provided
to suit the type of door specified. Stainless steel shall
conform to BS.

b Automatic door closer Model No.TS 92 cam action G


(Push/Pullside) or B (Push/Pull side) EN 2 to 4 of Dorma
make. (Door closer shall be provided to suit the type of door
opening / opening policy specified. Ie. Double / Single leaf Each 100
and Push / pull side) with all other accessories.(To use
Shutter width upto 1100 mm)
c Extra rate over and above item no a & b for making opening
in Toilet door in all blocks / floors for fixing the Air Transfer
grill
i 500 x 300 mm
Each 35
ii 300 x 200 mm
Each 420
3.06 Providing and fixing in position frames of any size and
section for Doors, Windows, Ventilators, any openings and
in Jambs,shaped, planed and fixed with necessary jointing
method approved including pins, nails, screws and bolts
etc. Rate shall include for cost of bolts, nuts, screws,
nails, pins, Hot dip galvanised MS approved hold fast and
concrete block grouting for fixing hold fast, anchor fasteners
/ coach screws and including a coat of suitable primer on
the frames to receive the Duco paint finish / Fire Retardant
paint with suitable primer of approved colour etc. complete,
as directed.

a) First class Teakwood confirming to IS specifications and


should be free from any defects and plemishes. Cum 15

b First class Padauk wood conforming to IS specifications


and should be free from any defects and plemishes. Cum Qro

3.07 Providing and fixing of MS handrail 1000mm clear height


from finished floor level 2 nos of 25 mm dia M.S pipe as
horizontal at equal distance should be welded with vertical
pipe of 32 mm dia and 16 mm dia with M.S bar welded to
12 mm thick plate embedded into concrete and 12 mm dia
square bar at the end and top finished with 50 mm dia Rmt 850
G.I.pipe as shown in the drawing including necessary tools
and plants required etc.and finishing etc. complete including
one coat of primer and two coats of paint.

C.R.Narayana Rao
Architects &Engineers 76 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.08 Providing and fixing of MS wall side railing using 50 mm dia


B class GI pipe for horizontal and 32 mm dia B class GI
pipe for supporing the horizontal pipes with the wall at 600
mm centres and firmly fixing them into the wall using with
necessary fixtures as shown in the drawings including one Rmt 850
coat of approved primer and two coats of synthetic enamel
paint of approved colour and make etcc complete in all
respects as directed by the engineer in charge.

3.09 Providing and erecting in position including assembling,


fitting and fixing approved make MS painted plain rolling
shutter with partly grill to a height of 600 mm at a height of
900 mm from finished floor level, made out of 20 Gauge
MS links to a width of 75 mm, M.S. links 150 x 75 mm in the
rolling grill portion with link opening of 115 x 45 mm together
with 10 mm dia. hard drawn seamless tubes and the end
sealed with mild steel clips etc. conforming to IS
specification.
The side MS guide channel shall be 75 x 25 mm (10 gauge)
welded lugs fixed to wall / Column, 10 gauge reinforced
lock plate rivetted to 40 x 40 x 6 mm angle with 40 x 40 x 6
mm stiffener welded on rear side with necessary locking
arrangements for both sides including pipe roller
conforming to IS 4454, all complete including top cover /
hood for rolling shutter as per specification for various
structural openings, etc. complete, as directed. Rate shall
include for two coats of first quality synthetic enamel
paint over a coat of zinc phospate primer, necessary tools
& plants, welding and consumables, etc. complete, as
directed.

Note : Clear structural opening will be measured and paid


for. The hood/ hood cover area will not be measured
separately.

Specification same as above, but for providing M.S plain


rolling shutter duly painted including all accessories.
Note : Clear structural opening will be measured and paid Sqm 7.5
for. The hood/ hood cover area will not be measured
separately.

3.10 Providing and fixing Heavy duty grating with an opening of


50mm square for trenches and drains of varying width
between 450 to 750mm( Clear Opening), grating made out
of galvanized steel and all as per manufacture's
specification of M/s Indiana gratings including necessary
supports , suitable angle iron frames , grouting the supports
using C.C 1:2:4 and finishing the surface neatly, welding Sqm 100
the angle/Flat with consumables, Painting iron frame with 2
coats of Synthetic Enamel paint over a coat of Zinc
phosphate primer etc. complete and all as directed. Note :
Clear opening will be measured and paid for.

C.R.Narayana Rao
Architects &Engineers 77 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.11 Providing and fixing in position first quality teak wood


beading / architrave of finished size as given below, made
to shape and pattern approved with necessary pins, nails,
screws, bolts using teakwood conforming to specification.
Rate shall include two coats of Duco Paint over a coat of
wood primer etc. as directed.

a Size : 32 x 12 mm Rmt Qro


b Size : 25 x 12 mm Rmt 2395
3.12 Supplying and fixing Fully openable Patch Fitting door with
fixed anels (Double / Single leaf door) of 'DORMA' or
approved equivalent make with "Universal" range Fittings
and with all other hardwares. In general, the door cum
Fixed panel consists of patch Fittings PT - 91, PT-25 & 20
with BTS 80 V Floor spring with SS cover plate (if the
shutter width not more than 1100 mm), Standard Spindle
PT 10 patch, US 10 corner lock at top & bottom, Euro
profile cylinder, lock keeper plate on the floor to secure the
bolt of the corner lock, OGRO handle of Model no TG 9355
of size 30x900mm to any shape in SS Satin Finish and
12mm thick clear toughened glass with 3M frosted film to
form a etching pattern as per design and all confirming to
manufacturers specification. SS fixtures shall conform
Grade SS 316 Grade to BS 7352.

Rate shall include for designing the system to withstand the


design wind pressure of 150 kg / sqm, providing Glass Fin
to support the Patch Fitting Door, transport charges,
handling, loading and unloading, Installation, Power
required for erection, protecting the module and glass till
handing over, testing, commissioning all necessary
hardwares, Structural supports if any, etc. complete and all
as per manufacturers' specifications as directed.

Sqm 650
a Double Leaf door with Top & side Fixed panel

Sqm Qro
b Single Leaf door with Top & side Fixed panel

Total C/o.to Summary of 3 B in Rs.

4.00 INTERNAL AND EXTERNAL FINISHES


4.01 Plastering of walls with cement mortar 1:4, 20 mm thick with
a neat floating coat of cement for smooth finish according to
specifications. Rate shall include for providing G.I.chicken
mesh made out of galvanised iron of nominal thickness
0.35 mm with a Zinc coating of 120 gms per Sqm at the
junctions of masonry and concrete works to a width of 100 Sqm 81350
to 125mm including tying in position with suitable
clamps/screws,necessary staging,scafolding and curing at
all levels and elevations etc.complete as directed.

C.R.Narayana Rao
Architects &Engineers 78 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.02 Plastering of R.C walls, peripheral beams and columns with


CM 1:3, 12 mm thick with a neat floating coat of cement for
smooth finish according to the specification. Rate shall
include for providing G.I.chicken mesh made out of
galvanised iron of nominal thickness 0.35 mm with a Zinc
coating of 120 gms per Sqm at the junctions of masonry Sqm 1000
and concrete works to a width of 100 to 125mm including
tying in position with suitable clamps/screws,necessary
staging,scafolding and curing at all levels and elevations
etc.complete as directed.

4.03 Plastering of ceiling including slabs, beams and column


drops and staircase waist slabwith CM 1:3, 6 mm thick with
a neat floating coat of cement for smooth finish according to
the specification. The rate shall include necessary Sqm 500
scaffolding, form work and curing etc. complete all as
directed.

4.04 Plastering for external surfaces with base coat of 20 mm


thick in C.M 1:4 with water proofing compound of CICO
No.1 or equivalent as per Manufacturer's Specification and
finishing coat of 10 mm thick in C.M 1:3 after roughening
the surface of first coat in green condition with wire brush
and clearing of loose particles with sponge finish (washed Sqm 9500
sand finish) all complete as per specification and as
directed. Rate shall include for providing drip bands /
moulds / grooves to any size and shape as directed.

4.05 Providing 15 mm thick water proof plaster in Toilet internal


walls and over head tank with CM 1:3 with water proofing
compound of CICO No:1 or equivalent as per
manufacturers specification and roughening the surface in Sqm. 5850
green condition with wire brush and clearing of loose
particles with sponge brush (washed sand finish)

4.06 Applying white washing three coats to ceilings and walls


with pure shell lime or fat lime conforming to IS-712 all as
per Specification and as directed. For shaft , lift interior Sqm 500
walls.

4.07 Providing two coats of first quality water proof cement paint
of approved make and colour over a priming coat of white
colour water proof cement paint or any primer specified by
the manufacturer including preparation of surface by
Sqm 1500
thorough cleaning and wetting before painting and curing all
as per manufacturer`s specifications and as directed.

C.R.Narayana Rao
Architects &Engineers 79 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.08 Providing two coats of BELCO- Acrylic emulsion paint of


Egg-Shell Finish (Supreme 3 in1of Dulux) to walls of
approved colour over a coat of Dulux Cement Primer (
solvent based ) - 34-200 of ICI make, including
preparation of surface by thorough cleaning and free from
grime,dust,grease, loose or flaking particles, if any Sqm 40500
haircracks shall be filled, smoothenout the surface by using
ICI Readymix Water Filler (33-500) followed by a coat of
water based cement primer - ( 32-168 ) as per
manufacturers specification fully to give an even shade
before painting as directed.

4.09 Providing two coats of "Dulux Weathershield Max paint of


approved shade and colour over a coat of ICI Exterior
acrylic Primer, including preparation of surface by through
cleaning and wetting before painting and curing all as per Sqm Qro
manufacturer's specification and as directed.

4.10 Providing Novakote Pliolite resin solvent based flat paint for
exterior surface as per Manufacturers specification and as
directed. Rate shall include for preparation of surface,
Sqm 5000
scaffolding if any, and cleaning the surface after applying
etc. complete, and as directed.

4.11 Providing three coats of 'PLASTIC 'emulsion paint to walls


/ ceiling of approved colour over a coat of water based
primer including preparation of surface by thorough
cleaning and wetting and applying POP/Gypsum powder
Sqm 41000
putty as per manufacturers specification fully to give an
even shade before painting and curing as per
manufacturers specifications and as directed.

4.12 Supplying and applying "RENOVA" Synthetic plaster over


the prepared plastered surface at three coats. The first coat
of application to be done with Renova ASP by trowel. The
second coat with brush and the final coat should also be
applied with brush. The rate shall include for carrying out Sqm 5000
work at all levels, all necessary surface preparation, tools,
scaffolding, taxes etc., all complete. The rate also includes
all colour shades, texture and as pattern per manufactures
shade card.
4.13 Painting with lustre paint of approved shade and colour of
ICI / Asian Paint or equivalent make, by sand papering the
surface, then applying a coat of primer, then applying two
coat of putti, again sand papering the surface and applying
the coat of paint with roler finish as per Manufacturers Sqm Qro
specification and as directed. Rate shall include for
preparation of surface, scaffolding if any, and cleaning the
surface after applying etc. complete, and as directed.

C.R.Narayana Rao
Architects &Engineers 80 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.14 Providing two coats of "Sandtex - matt paint of snoecem or


Weathercoat of Berger Make of approved shade and
colour over a coat of cement paint primer, including
preparation of surface by through cleaning and wetting
Sqm Qro
before painting and curing all as per manufacturer's
specification and as directed. For external walls of
basement interior wall and inside tunnel wall.

4.15 Extra rate over plaster item rate for providing Plaster mesh
made out of galvanised iron of nominal thickness 0.35 mm
with a Zinc coating of 120 gms per Sqm at the junctions of
Masonry and concrete works to a width of 100 to 125 mm
including tying in position with suitable clamps / screws etc.,
complete and as per manfacturer specification,from M/s.
Arpitha exports, Bangalore. Rate shall include for
preparation of surface, cleaning, curing etc. complete, all as
directed. as directed.

Note : This item shall be operated only for doing chipping


and chasing done for services, embedding the pipes /
conduites, if specifically ordered, since the plastermesh
shall be provided within the quoted rate of plastering items. Rmt 1000 -
Provision of mesh for regular junction and similar materials
shall not be measured for payments.

4.16 Providing and fixing Galvanised steel corner bead of size


45x45 mm made out of galvanised iron of nominal thickness
0.35 mm with a Zinc coating of 120 gms per Sqm as
protector for plastered wall and coloum corners from
chipping and Corner, at the junction of plaster end and
other meterials, including tying in position by using suitable Rmt 500 -
nails / clamps / screws etc. complete and as per
manfacturer specification from M/s. Arpitha exports,
Bangalore. Rate shall include for preparation of surface,
cleaning, curing etc. complete, all as directed.

4.17 Providing and fixing Galvanised Plaster stop bead of size


58 to 60 x 10 to 19mm made out of galvanised iron of
nominal thickness 0.35 mm with a Zinc coating of 120 gms
per Sqm as protector for plastered wall and coloum corners
from chipping and Corner, at the junction of plaster end and
other meterials, including tying in position by using suitable
Rmt 500
nails / clamps / screws etc. complete and as per
manfacturer specification from M/s. Arpitha exports,
Bangalore. Rate shall include for preparation of surface,
cleaning, curing etc. complete, all as directed

C.R.Narayana Rao
Architects &Engineers 81 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.18 Providing and fixing of Rubber corner bead to protect


parking area columns made out of rubber of size 50 MM X
50 MM and length 1.00 mts thinkness 6 MM and base
material galvanized iron of nominal thickness 1.00 mm with
a Zinc coating of 120 gms per Sqm at the corners including
tying in position with suitable nails / screws etc., complete Rmt 1000
and as per manufacturer specification, from M/s. ARPITHA
EXPORTS, (Equivalent) Bangalore. Rate shall include for
preparation of surface, cleaning, curing etc. complete, all as
directed by the architect / Engineers.

4.19 Providing and fixing of PVC Inner Corner Tile Beading /


External Round edge trims of M/s Arpitha Exports or
approved equivalent of nominal thickness 1.2 mm of
approved Colours & required depths for vertical and
Horizontal corners and edges l including preparation of Rmt 2500
surface etc. all complete, as directed by the Engineer-in-
charge.

Total C/o.to Summary of 3 B in Rs.

C.R.Narayana Rao
Architects &Engineers 82 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

SECTION 3 C - SUBSIDIARY WORKS

1.00 ROADS & PATHWAYS

1.01 Site clearence including removal of Shurbs & Vegetation


upto the bottom of the root including clearing them away
from the site levelling the undulated ground etc. complete, Sqm 9300
as directed.
1.02 General Excavation by mechanical means in all types of soil
including dense soil, discentegrated/ weathered / soft rock
including necessary manual excavation for dressing the
edges & leveling, all leads and lifts back filling in layers of
150mm with watering, spreading in layers to the required
levels within the site wherever specified, and compaction
dewatering of both ground and surface water, removal of
Cum 3300
slurry generated while excavation and keeping the area free
of water with necessary shoring, struting, required for
keeping earth in position etc,. excavating loose pockets and
compacting the same. Note: Authorised working space and
Provision of slopes if required for execution shall not be
paid separately.

1.03 Carting away surplus earth / excavated material / debris


and like materials and disposing off the same to the
desingrated areas identified by the local authorities /
Engineer in Charge for dumping of such material, including Cum 1000
spreading, compacting etc., as per the norms by the local
authorities.
1.04 Preparation of sub-grade and compacting the same with 8
to 10 ton power roller including forming camber and
gradients watering and rolling to reach required density Sqm 9300
complete.

1.05 Providing and laying granular sub-base of sand gravel mix


in proportion 1:1 for sub-base to a compacted thickness of
300 mm laid in two layers of 150 mm thick each layer using
good quality gravel and sand from approved source and
mixed in the specified proportion stacking stand and gravel
to standard gauge for pre-measurement including cost and
conveyance of all materials to site and mixing sand gravel
in the specified proportion spreading after mixing to
required camber, levelling, watering with all leads to obtain
Sqm 9300
moisture levels of mix between 1% above and 2% below
the optimum moisture content at the time of compaction
and compacting each layer with power roller to obtain the
required proctor density including all labour, hire and fuel
charges for all tools and plants employed and all other
incidental charges etc. all complete as per IRC and IS
Specifications and as directed.

C.R.Narayana Rao
Architects &Engineers 83 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

1.06 Providing and laying water bound macadam base course


for a consolidated thickness of 150 mm thick in two layer s
of 75 mm thick using 1 Cum of 63 mm to 45 mm IRC size
Coarse graded aggregate with 0.24 Cum of gravel for
blindage and filler material for 10 sqm area of each layer
and as directed by the Engineer including cost and
conveyance of all materials from any source to work site,
stacking to standard gauge for pre-measurement, labour Sqm 9300
charges for spreading and packing to camber, watering with
all leads for water, forming edge bund and consolidation by
power roller including all labour, hire and fuel charges for all
tools and plants employed and all other incidental charges
etc. all complete as per IRC Specification and as directed.

1.07 Providing and laying water bound macadam base course


for a consolidated thickness of 75 mm using 1.00 Cum 53
mm to 22.40 mm IRC size Coarse graded aggregate with
0.24 Cum of gravel blindage and fill material for 10 Sqm
area and as directed including cast and conveyance of all
materials from any source to work site, stacking to standard
gauge, labour charges for spreading and packing to
Sqm 9300
camber, watering with all leads for water, forming edge
bund and consolidation by power roller including all labour,
hire and fuel charges for all tools and plants employed and
all other incidental charges etc. all complete as per IRC
specifications and as directed.

1.08 Providing and laying plain cement concrete 1:3:6 using


coarse graded aggregate of 25 mm and down size for
levelling course including laying in layers of thickness not
exceeding 150mm and in alternative bays not exceeding 10
sqm as directed including form work wherever necessary Cum 940
and well compacted etc. all complete, as directed.

1.09 Supplying and laying precast concrete hydraulically pressed


uniregular machine made interlocking paving blocks of
approved design - 65 mm thick (To give a compressive
strength of not less than 50 N/Sqm or 500 Kg/Sqm)
transportation of the blocks to the site preparation of
surface including supplying and filling with dry river sand to
50 mm thick, levelling and compacting with plate vibrator
and laying of the inter locking paving blocks with sand
binding and final compaction with plate vibrator of 3 tonne
capacity finishing the surface including cutting of blocks at
the edges including all labour and materials etc complete,
as directed.

a Natural grey colour


Sqm 8300
b Terracota colour
Sqm 1000

C.R.Narayana Rao
Architects &Engineers 84 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

1.10 Providing thermoplastic painting for car park and road line
involving cleaning the surface free of dirt and loose
particles applying one coat of primer and two coats of
thermoplastic paint wih drop on glass beads. Rate shall Sqm 50
include for all materials & labour components etc.,
complete.

1.11 Providing 'L' shaped precast reinforced cement concrete


M25 grade road kerbs of size 175 x 90 mm made to shape
using 20 mm down size Coarse graded aggregate including
form work and nominal reinforcement of Fe 415 grade, 12
mm dia at 150 c/c with 8 mm dia stirrups at 150 mm c/c
fixing in cement concrete 1:3:6 nominal mix including Rmt 2000
pointing exposed faces with C.M 1:3 and colour washing
with acrylic distember over a coat of primer etc. complete,
as directed.

1.12 Providing supplying and fixing ARROW shape precast inter


locking cement concrete kerbs from ASTANA or equivalent.
The over all size of kerb shall be 400 x 300 x 120 mm made
to shape as shown in the drawing by using M25 grade of
concrete, using 12 mm and down size coarse graded
aggregate including fixing in cement concrete 1:4:8 and Rmt 100
painting with approved colour and shade complete etc.
The quoted rate to inclusive of supplying the product from
the factory, wastages due to transportation and fixing.etc.

Total C/o.to Summary of 3 C in Rs..

2.00 DRAINS & TRENCHES

2.01 Excavation in any kind of soils excluding Soft Dis-Integrated


rock., for foundations of drains, trenches and tunnels at all
levels and to any depth below average ground level,
including shoring, strutting, pumping and bailing out water,
de-watering if any so as to keep foundations in dry
condition at any stage of work, drain the water away from
the site through sub drain and connecting into main drain,
lead & lift, loading & unloading and backfilling with selected
excavated material around Foundation & Trenches etc,
disposing the excavated soil by mechanical means, as
directed. Rate shall include cost of excavation of working
space as required, slopes and berms as per site soil
condition/nature of the site soil and safety of excavation.
Rate shall also include for refilling the such excavation of
working space with approved filling Material including
consolidating to the required proctor density.

C.R.Narayana Rao
Architects &Engineers 85 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Note : Length and width at bottom of foundation and depth


from the top of average ground level to the bottom of
foundation only will be measured for payment. Excavation
taken by the Contractor for working space as required,
slopes and berms as per site soil condition / nature of site Cum 5700
soil and safety of excavation will not be measured.Quoted
rate shall be deemed to have considered the above
stipulation.

2.02 Supplying and filling in foundations and the area wherever


required below ground level and sides of the foundation
and walls with approved river sand in layers not exceeding
150 mm thick,. including well watered and consolidation, Cum 330
levelling, loading, unloading and transportation etc.
complete, and as directed.

2.03 Providing and laying plain cement concrete 1:4:8 using


coarse graded basalt aggregate of 25 mm and down size
for levelling course in foundation and under floors, steps,
walls, platform and in-fill concrete whereever is required etc.
including laying in layers of thickness not exceeding Cum 330
150mm and in alternative bays not exceeding 10 sqm as
directed including form work wherever necessary and well
compacted etc. all complete, as directed.

2.04 Providing, batching, mixing, transporting through transit


mixers, pumping and laying controlled Reinforced Cement
Concrete of specified grade at all levels and heights
specified below using ordinary Portland cement of grade 43
/ grade 53 from approved manufacturer, river sand, 20mm
and down size coarse aggregates, necessary Mineral
admixtures approved by Consultants (elkem and Conplast
SP 430SRV from Fosroc or equivalent), including all leads
and lifts, pumping using line pump or boom placer,
vibrating/ compaction, scaffolding wherever necessary,
curing as directed, excluding cost of shuttering and
reinforcement works.

(Design mix shall be as approved by the Structural


Consultant / Employer's representatives

M30 Grade

i Raft Slab Cum 580


ii Side walls Cum 715
iii Cover slab Cum 255

C.R.Narayana Rao
Architects &Engineers 86 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.05 Providing, fixing reinforced cement concrete precast slab


with controlled cement concrete - M20 grade using coarse
graded aggregate 12 mm and downsize for covering the
drain / trench / chambers/ manholes and such other works.
Rate shall include for providing necessary casting platform,
shuttering, finishing the exposed faces smooth wherever
necessary and pointing the joints with C.M 1:3, 15 mm
thick curing and fixing in position etc complete and as
directed. Rate shall include for fixing MS angles of required
size based on the thickness of precast slab and to be fixed
on the edges of the precast slab including grouting the lugs
with Cement concrete 1:1.5:3, GI Hooks for lifting the slab
etc complete, as directed. Necessary reinforcement MS
angles,MS lugs,GI hooks will be paid seperately in the
respective items.

a Cover slab with perforations Cum 15


b Cover slab with out perforations Cum 5
2.06 Providing, fabricating and erecting form work at all levels
and places wherever needed/specified as per drawing
including striking with 12mm Plastic coated, marine
resistant waterproof ply/Smooth finished MS plates with
adjustable steel props of acceptable Staging system and
with sufficient bracing as approved by consultant. Cost to
include designing of proper form work and staging system
to suit the requirements,Submission of design calculations
and shop drawings for approval,sealing the joints with
heavy duty brown self adhesive tape, aligning to line and
levels including M.S. Ties, PVC Spacer, Providing
openings/ cutouts/ pockets, applying deshuttering chemical,
Deshuttering as approved by the consultant etc., complete
at all levels, double/tripple heights and profiles for Note :
Only plan area shall be considered.No extra shall be paid
for Side shuttering of Drop panel/column capitals.

1) plywood shuttering shall be considered for all vertical


elements,beam
soffit,corewalls,stairs,ramps,tanks,RCCpedestals Etc.,
2) M.S. plates shall be considered for foundation,slabs
only.
3) Shuttering & deshuttering sequence shall be 100% ,80%
& 40% from the slab to be cast respectively

i Raft Slab Sqm 920


ii Side walls Sqm 6200
iii Cover slab Sqm 2300

C.R.Narayana Rao
Architects &Engineers 87 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.07 Providing and fixing reinforcement for RCC work with high
yield strength TMT bar of various diameters of Grade of
reinforced steel - Fe 500 - Thermex TMT bars conforming
to BIS specification including cutting, bending, fabricating
and placing in position according to drawings and binding
the reinforcement with 16 gauge galvanised annealed
binding wire of double fold or 18 gauge SS wires and
providing precast cement cover blocks for main
reinforcements to ensure specified cover according to
relevant IS code. The measurements will be in accordance MT 180
with IS code 1200.However reinforcement shall be
measured only in lengths of bars as actually placed in
position on standard weight basis, no allowance being
made in the weight for rolling margin. Authorised laps and
splices only will be measured. Chairs of any shape &
profile, Spacer bar of any shape & profile, wastage and
binding wire will not be measured and shall be included in
the quoted rates.

2.08 Providing and fixing in position M.S.chequered plate 5mm


thick with necessary supports such as M.S. angles/M.S.
flats including stiffeners to be placed on angle iron frame
work. (Frame work, angles, stiffners will be measured under
relavent structural steel item). Rate shall include making
necessary cutouts for inserts, applying one coat of Zinc MT 1
chromate/Phosphate primer and two coats of first quality
synthetic enamel paint of approved make etc complete,as
directed.

2.09 Providing and constructing cement concrete solid block


masonry work at all levels in cement mortar 1:3 using
standard size of 400 x 200 mm of solid cement concrete
blocks of thickness as given below, with minimum
compressive strength of 5.5 N/Sq.mm.conforming to the
relevant IS code including all scaffolding, staging, curing, all
lifts etc. complete and as directed. Concrete blocks
manufactured under strict quality control conditions using
modern rugged block casting and stripping machine with
the latest moulding techniques etc. only shall be used.

I Solid block wall of 600 mm thick Sqm Qro


ii Solid block wall of 400 mm thick Sqm Qro
iii Solid block wall of 200mm thick Sqm 50
2.10 Providing 15 mm thick water proof plaster in C.M 1:3,
finished smooth with a floating coat of neat cement using
CICO No: 1 or approved water proofing compound by Sqm 9300
weight to the required percentage as per Manufacturers
specification and as directed.

C.R.Narayana Rao
Architects &Engineers 88 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.11 Providing and laying in position the RCC hume 'pipes


(NP2) of approved quality and make including socket and
spigot jointing,.necessary Excavation, PCC 1:2:4 at
supports, Sand cushion of 150mm on all sides Refilling,
Compaction and making good the level,alignment
etc.,complete

1 150mm dia Rmt. 50


b 200 mm dia Rmt. 50
c 250 mm dia Rmt. 10
d 300 mm dia Rmt. 470
e 450 mm dia Rmt. 10
2.12 Providing and laying reinforced cement concrete heavy duty
NP3 type pipe of the following diameter with necessary
collars conforming to IS 458 including cost and conveyance
to site, laying to proper grade and alignment, jointing etc.
complete as per direction of the Engineer including cost and
conveyance of all materials to site, all labour, hire and fuel
charges necessary Excavation and refilling after laying the
pipelines including tools and plants employed and all other
incidental charges etc. complete as per specifications.

a. 100 mm dia. Rmt. Qro


b Upto 1.5m depth for 300mm dia data cable hume pipes Rmt 50
2.13 Providing and fixing PVC pipes of 4 kg / sqcm for DOT
trench with all specials, accessories and joints with solvent
cement solution according to manufacturers specification.

a. 50 mm dia RM. 2300


b. 110 mm dia. RM. 4200
c. 160 mm dia. RM. Qro
2.14 Providing and laying CC 1:3:6 concrete using coarse
graded aggregate of 25 mm down size for levelling course
under pipes and encasing RC hume pipes etc. as directed
including form work wherever necessary and compacted Cum 175
with wooden or cast iron rammers.

2.15 Providing 40 mm thick nominal thick pebble stone for the


rain water conservation trench including cost and
conveyance of pebble stone and filler materials, all labour,
hire and fuel charges for all other incidental charges such Cum 1850
as preparing the surface etc. complete as directed.

C.R.Narayana Rao
Architects &Engineers 89 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.16 Construction of collection chamber including earthwork


excavation to required size and depth including laying C.C.
1:2:4 - 200 mm thick using 25 mm and down graded
aggregate and laying brick work with 350 mm width brick
work for a depth of 500 mm and 230 mm width for the
remaining depth with best quality available chamber burnt
bricks conforming to IS 1077 including plastering inside
surface smooth with CM 1:3 and outside with CM 1:5, filling
the sides of trenches with excavated earth and disposing of
surplus earth away from the site etc complete, as directed.
(Over all Size chamber Given Below).

a. 900 x 900 mm depth upto 1 M depth. Each 5


b. 900 x 900 mm depth upto 1.5 M depth Each 5
c 1000 x 1000 mm depth upto 1m depth Each 25
2.17 Providing and fixing PVC (10 Kg/sqcm class) Heavy duty
pipe of specified dia below and approved make as water
down take pipe with all specials, accessories and joints with
solvent cement solution according to manufacturers
specification.
a. 75 mm dia Rmt 600
b 110 mm dia Rmt 100

Total C/o.to Summary of 3 C in Rs..

3.00 COMPOUND WALL

3.01 Excavation in all types of soil including dense soil,


disintegrated/ weathered/ soft rock (Poclainable) for
Footings of columns, Retaining walls, etc., by mechanical
means to all depth including manual excavation for leveling,
dressing the edges, with all leads and lifts including back
filling in layers of 150mm with watering and compaction.
dewatering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
Cum 1580
of water with necessary shoring, struting, required for
keeping earth in position etc, Rate to include disposing the
excess earth and spreading in layers to the required levels
within the site wherever specified by the local authorities.
Only plan area of the base PCC will be considered for
measurement

C.R.Narayana Rao
Architects &Engineers 90 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.02 Same as above item but for excavation in Hard rock /


boulders (more than 1/2 Cum in size -Un poclainable) by
chiseling/ wedging to required level at all depth for footings,
trenches, rafts, retaining wall, etc. to the required depth
including all leads and lifts, stacking excavated material
within plot at approved location and carting away
unserviceable material outside the site as directed,
dressing, grading, cleaning, excavating loose pockets and Cum 100
compacting them after backfilling as directed etc. as per
detailed specification and conforming to safety rules of
Authority during the progress of work. Only plan area of the
base PCC will be considered for measurement

3.03 Supplying and filling in foundations and the area wherever


required below ground level and sides of the foundation
and walls with the filling material specified below in layers
not exceeding 150 mm thick,. including well watered and
consolidation, levelling, loading, unloading and
transportation etc. complete, and as directed.

a Approved Good River Sand Cum 85


b With approved quality quarrydust brought from outside Cum 50
3.04 Providing and laying plain cement concrete 1:4:8 using
coarse graded aggregate of 40 mm and down size for
levelling course under columns, wall bases and plinth
beam etc. including necessary form work wherever Cum 85
necessary and compacted by wooden or cast iron rammers
as per Specification and as directed

3.05 Providing, batching, mixing, transporting through transit


mixers, pumping and laying controlled Reinforced Cement
Concrete of specified grade at all levels and heights
specified below using ordinary Portland cement of grade 53
/grade 43 from approved manufacturer, river sand, 20mm
and down size coarse aggregates, necessary Mineral
admixtures approved by Consultants (elkem and Conplast
SP 430SRV from Fosroc or equivalent), including all leads
and lifts, pumping using line pump or boom placer,
vibrating/ compaction, scaffolding wherever necessary,
curing as directed, excluding cost of shuttering and
reinforcement works.

(Design mix shall be as approved by the Structural


Consultant / Employer's representatives

M30 Grade

a Footing for Gate Pillatrs


Cum 15
b Tie beams
Cum 100
c Columns
Cum 90

C.R.Narayana Rao
Architects &Engineers 91 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

d Coping slab
Cum 52
e Planter box
Cum 5
3.06 Providing, fabricating and erecting form work at all levels
and places wherever needed/specified as per drawing
including striking with 12mm Plastic coated, marine
resistant waterproof ply/Smooth finished MS plates with
adjustable steel props of acceptable Staging system and
with sufficient bracing as approved by consultant. Cost to
include designing of proper form work and staging system
to suit the requirements,Submission of design calculations
and shop drawings for approval,sealing the joints with
heavy duty brown self adhesive tape, aligning to line and
levels including M.S. Ties, PVC Spacer, Providing
openings/ cutouts/ pockets, applying deshuttering chemical,
Deshuttering as approved by the consultant etc., complete
at all levels, double/tripple heights and profiles for Note :
Only plan area shall be considered.No extra shall be paid
for Side shuttering of Drop panel/column capitals.

1) plywood shuttering shall be considered for all vertical


elements,beam
soffit,corewalls,stairs,ramps,tanks,RCCpedestals Etc.,
2) M.S. plates shall be considered for foundation,slabs
only.
3) Shuttering & deshuttering sequence shall be 100% ,80%
& 40% from the slab to be cast respectively

a Footing for Gate Pillatrs Sqm 40


b Tie beams Sqm 500
c Columns Sqm 745
d Coping slab Sqm 845
e Planter box Sqm 45
3.07 Random rubble masonry in CM 1:6 including flush pointing
with CM 1:3 after raking out joints, curing etc. with all
necessary bond stones to full width of the wall in every Cum 935
layers and staggered, all complete and as directed in
foundation and basement
3.08 Providing and constructing cement concrete solid block
masonry work at all levels in cement mortar 1:3 using M -
5.5 Grade blocks of size 400 x 200 mm x 200 mm of solid
cement concrete blocks, .conforming to IS 2185 or
equivalent BS including all scaffolding, staging, curing, all Cum 320
lifts etc. complete and as directed. Concrete blocks
manufactured under strict quality control conditions using
modern rugged block casting and stripping machine with
the latest moulding techniques etc. only shall be used.

C.R.Narayana Rao
Architects &Engineers 92 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.09 Providing and fixing reinforcement for RCC work with


Thermo mechanically treated (TMT) bar of various
diameters and grade of steel as specified below conforming
to IS or equivalent BS specification including cutting and
waste, bending, hoisting, fabricating and placing in position
according to drawings and binding the reinforcement with
galvanised annealed binding wire of double fold of 18
gauge and providing PVC cover blocks for placing the
reinforcements in position and for maintaining the cover
specified and/or according to relevant IS or equivalent BS
code.
Note : Unless noted otherwise the measurements in
accordance with IS 1200 or equivalent BS. However
reinforcement shall be measured only in lengths of bars as
actually placed in position on standard weight basis, no
allowance being made in the weight for rolling margin.
Authorised laps and splices, Chairs of any shape & profile,
Spacer bar of any shape & profile, cover block, wastage
and binding wire will not be measured and shall be included
in the quoted rates.Quoted rate shall be deemed to have
considered the above stipulation.Quoted rate to include
lead, lift, placing at all levels and as directed. Detailing of
the reinforcement shall be ductile detailing for seismic
zone III as per codal requirement.

Grade of reinforced steel - Fe 500


Kgs 44100
3.10 Providing and fixing in position Hot rolled structural steel
Members / Sections at all levels and to any shape & profile
consisting of MS joists, channels, angles, purlins, runners,
insert plates, flats and sag rods with necessary sleeves,
bolts and nuts, gratings, pipes including cutting,
straightening, welding as per standards for connections
including consumables etc.complete. Rate shall include Kgs 1000
preparation of surface, applying two coats of Zinc
chromate/Phosphate primer before and after erection and
two coats of first quality synthetic enamel paint of approved
make after erection, sand blasting etc. complete, as
directed.
3.11 Providing and fixing welded M.S. grills along the
compound wall to details as per drawing with necessary
screws, bolts and fixed with necessary M.S. lugs
embedded in masonry with C.C. 1:2:4 and finishing the
surface neatly. Rate shall include for two coats of first Kgs 28400
quality synthetic enamel paint over a coat of zinc
phospate primer, necessary tools & plants, welding and
consumables, etc. complete, as directed.

C.R.Narayana Rao
Architects &Engineers 93 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.12 Providing and fixing Compound wall gate of the following


size and specifications as per the detailed drawing.
a. MS openable swing gate consisting of double leaf using
50mm solid sections for outer frame and 16mm square bars
for intermediate frames as stiffnner and 16mm square solid
sections for vertical members at 75mm c/c as shown in the
drawing including necessary, locking arrangements,
holdfast and hinges fixed into the masonry or R.C.works
and providing gunmetal roller fixed to the main frame at KG 2500
bottom to facilitate swinging of the gate and it should be
supported over the M.S.flat of size 50 x 10 mm thick firmly
fixed to the ground etc.complete all as directed and
applying two coats of enamel paint etc. complete.

b. M.S.Wicket Gate of size 1200 x 1200 mm using 30mm


square hollow sections for both outer and intermediate
frames and 20mm square solid sections at 75mm c/c for
vertical members as shown in the drawing including KG 1200
necessary locking arrangements, hinges, holdfast
etc.complete as directed and applying two coats of enamel
paint etc. complete.
3.13 Fabricating supply and erection of M.S sliding gate with
necessary wheels,track,slash trail guide rollers (2 sets )
guide posts finished with one coat ZINC Chromate primer
cost includes supply and installing italian make power drive
with protocell adstruction detection system and two nos of Sqm 20
remote control with receiver and transmeter for motors )
and applying two coats of enamel paint complete.

3.14 Providing wall cladding with best quality approved colour


granite slab of sadarahalli grey not less than 20 mm thick
machine cut and machine high pre-polished, set in C.M 1:4,
20 mm thick topped with white cement slurry (for surface
contact of the bottom of the granite slab) as per approved
pattern/design including finishing the joints with white
cement slurry, cutting, edge chamfering and polishing Sqm 305
rough, medium, nice and acid wash and tin-oxide polish
as per manufacturer's Specification and as directed.Rate
shall include for preparation of base surface & finished the
surface, work at all levels and as directed.

3.15 Supplying and laying decorative ornamental tiles of Eurocon


over a bed of C.M.1:3 12mm thick. Rate to include all
necessary wastages of tiles and joints between the tiles
should be neatly finished with tile matching cement slurry.
Rate shall include for preparation of surface, cleaning and
acid wash etc., complete at all levels and as directed.

a Size 380 x 76.5mm (Corfu)


Sqm 165
b Size 152mm x 152mm (Cordova)
Sqm 50

C.R.Narayana Rao
Architects &Engineers 94 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.16 Plastering of walls with cement mortar 1:4,15mm thick with


a neat trowel finish according to specification. Rate shall
include for scaffolding, formwork as necessary and curing Sqm 1480
etc. complete as directed.
3.17 Providing and constructing of plaster grooves of size 25mm
x 5mm thick over the plastered surfaces as shown in the
drawings including cost of all materials and labour etc. Rm 660
complete.
3.18 Providing two coats of rough cast plaster over prepared
surface consisting of 8 mm thick C.M 1:5 under coat laid
uniform and left rough and final coat of 12 mm thick with a
mix of one part of cement and two parts of 12 mm
maximum size graded aggregate, prepared into a paste Sqm 1480
and then applied over the under coat by means of large
trowel to form an even coat. The final coat is applied
before setting of the under coat as directed.

3.19 Providing two coats of first quality Waterproof cement paint


of approved brand and colour to plastered walls over a coat
of approved primer either of cement based primer including
preparation of surface through cleaning and wetting and
applying pop/Gypsum powder putty as per manufacturers
specification fully to give an even shade before and Sqm 2950
subsequent application and making good all small holes of
nails, open joints and minor defects of every kind after
application of priming coat all as per Specification and as
directed.

3.20 Provide expansion joints at distance as specified in the


drawing at junctions of vertical faces of walls with 20 mm
thick Thermocole - TF variety including keeping in position
during concreting as per specification. The top and bottom /
both sides of wall vertical face of expansion joint shall be
treated with 20 mm deep Silicon sealant of Dow Corning or Sqm 85
approved equivalent make and as per Manufacturers
Specification etc. all complete as directed.
Note: Superficial area including thickness of sealant as laid
in position shall be considered for payment.

3.21 Providing and fixing Weep holes with 75mm dia heavy duty
(6Kg / Sqcm) PVC pipe at locations indicated and as
directed. Rate to include for providing filter bed 300mm x RM 420
300mm deep with coarse aggregate
3.22 Supplying and fixing 50mm dia. and 200mm or more long
G.I. pipe spouts including painting two coats of first quality
synthetic enamel paint of approved make and tint over one Each 15
coat of primer all as per specification and as directed.

Total C/o.to Summary of 3 C in Rs..

C.R.Narayana Rao
Architects &Engineers 95 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.00 HSD TANK


4.01 Excavation in all types of soil including dense soil,
disintegrated/ weathered/ soft rock (Poclainable) for
Footings of columns, Retaining walls, etc., by mechanical
means to all depth including manual excavation for leveling,
dressing the edges, with all leads and lifts including back
filling in layers of 150mm with watering and compaction.
dewatering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free Cum 165
of water with necessary shoring, struting, required for
keeping earth in position etc, Rate to include disposing the
excess earth and spreading in layers to the required levels
within the site wherever specified by the local authorities.
Only plan area of the base PCC will be considered for
measurement

4.02 Same as above item but for excavation in Hard rock /


boulders (more than 1/2 Cum in size -Un poclainable) by
chiseling/ wedging to required level at all depth for rafts,
retaining wall, catch pits, etc. to the required depth including
all leads and lifts, stacking excavated material within plot at
approved location and carting away unserviceable material
outside the site as directed, dressing, grading, cleaning, Cum 50
excavating loose pockets and compacting them after
backfilling as directed etc. as per detailed specification and
conforming to safety rules of Authority during the progress
of work. Only plan area of the base PCC will be considered
for measurement

4.03 Supply and filling in foundations and the area whereever


specified with approved good quality filling materials in
plinths, area development etc. wherever specified in layers
of not exceeding 150 mm thick including breaking
clods,storing,transportation ,double handling, watering,
compacting each layer with vibratory compactor and at
unaccessible places with wooden/steel rammers to achieve
90 to 95% proctor density at optimum moisture content, all
leads and lifts, bailing/ pumping out of water to keep site dry
while backfilling; cost shall include conveyance of all
materials, labour, machinery etc. complete as directed.The
rate to includes loading,unloading, hire and fuel charges for
tools and plants and other incidental charges etc.,
complete.

a With approved quality murrum brought from outside.


Cum 10
b Approved quality river sand brought from outside
Cum 20
c With approved quality quarrydust brought from outside
Cum 25

C.R.Narayana Rao
Architects &Engineers 96 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.04 Providing and laying plain cement concrete 1:4:8 using


coarse graded aggregate of 40 mm and down size for
levelling course under footings, steps, walls, platform etc.
including laying layers of specified thickness in alternative Cum 20
bays not exceeding 10 sqm as directed including form work
wherever necessary and well compacted etc. all complete,
as directed.
4.05 Providing, batching, mixing, transporting through transit
mixers, pumping and laying controlled Reinforced Cement
Concrete of specified grade at all levels and heights
specified below using ordinary Portland cement of grade 53
/ grade 43 from approved manufacturer, river sand, 20mm
and down size coarse aggregates, necessary Mineral
admixtures approved by Consultants (elkem and Conplast
SP 430SRV from Fosroc or equivalent), including all leads
and lifts, pumping using line pump or boom placer,
vibrating/ compaction, scaffolding wherever necessary,
curing as directed, excluding cost of shuttering and
reinforcement works.
(Design mix shall be as approved by the Structural
Consultant / Employer's representatives

M30 Grade

Cum 22
a RC walls

Cum 18
b Raft slab

Cum 25
c Pedestals
4.06 Providing and laying reinforced cement concrete1:2:4 using
coarse graded aggregate of 20 mm and down size for
floors of unloading platform including necessary lead and
lifts, tools & Plants, pumbing the concrete to all levels,
curing and necessary centering and shuttering but Cum 5
excluding cost of reinforcements. Depending on the size
and location, the maximum depth of concreting will be
decided by Engineer in casting at a time.

C.R.Narayana Rao
Architects &Engineers 97 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.07 Providing, fabricating and erecting form work at all levels


and places wherever needed/specified as per drawing
including striking with 12mm Plastic coated, marine
resistant waterproof ply/Smooth finished MS plates with
adjustable steel props of acceptable Staging system and
with sufficient bracing as approved by consultant. Cost to
include designing of proper form work and staging system
to suit the requirements,Submission of design calculations
and shop drawings for approval,sealing the joints with
heavy duty brown self adhesive tape, aligning to line and
levels including M.S. Ties, PVC Spacer, Providing
openings/ cutouts/ pockets, applying deshuttering chemical,
Deshuttering as approved by the consultant etc., complete
at all levels, double/tripple heights and profiles for Note :
Only plan area shall be considered.No extra shall be paid
for Side shuttering of Drop panel/column capitals.

1) plywood shuttering shall be considered for all vertical


elements,beam
soffit,corewalls,stairs,ramps,tanks,RCCpedestals Etc.,
2) M.S. plates shall be considered for foundation,slabs
only.
3) Shuttering & deshuttering sequence shall be 100% ,80%
& 40% from the slab to be cast respectively
Sqm 200
a RC walls
Sqm 15
b Raft slab
Sqm 125
c Pedestals
4.08 Providing and fixing reinforcement for RCC work with
Thermo mechanically treated (TMT) bar of various
diameters and grade of steel as specified below conforming
to IS or equivalent BS specification including cutting and
waste, bending, hoisting, fabricating and placing in position
according to drawings and binding the reinforcement with
galvanised annealed binding wire of double fold of 18
gauge and providing PVC cover blocks for placing the
reinforcements in position and for maintaining the cover
specified and/or according to relevant IS or equivalent BS
code.

Note : Unless noted otherwise the measurements in


accordance with IS 1200 or equivalent BS. However
reinforcement shall be measured only in lengths of bars as
actually placed in position on standard weight basis, no
allowance being made in the weight for rolling margin.
Authorised laps and splices, Chairs of any shape & profile,
Spacer bar of any shape & profile, cover block, wastage
and binding wire will not be measured and shall be included
in the quoted rates.Quoted rate shall be deemed to have
considered the above stipulation.Quoted rate to include
lead, lift, placing at all levels and as directed. Detailing of
the reinforcement shall be ductile detailing for seismic
zone III as per codal requirement.

C.R.Narayana Rao
Architects &Engineers 98 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

I Grade of reinforced steel - Fe 500


MT 10

4.09 Supplying, fabricating and fixing in position inserts


comprising edge angle, MS angles, plates, tees, flats and
other structural steel sections, holding down bolts, anchor
bolts, anchor plates, pipe sleeves etc., in all cement
concrete works at all levels and heights above finished floor
level in foundation, trenches, pits, tunnels, lift pits etc.,
below finished floor level and M.S. plates in floor including
cutting, bending to shape fabricating, drilling, threading, MT 2
welding lugs etc., with all tools, tackles and labour as per
design or as directed including a coat of primer of approved
quality and painting the exposed surface with two coats of
synthetic enamel paint of approved quality and colour etc.,
all complete as per drawings and as directed.

4.10 Providing, fabricating & fixing weld mesh fencing along with
weld mesh gate, comprissing of RCC precast post of 2.0m
ht @ 2.4m c/c with varying size as per drawing including
fixing the weld mesh -14 gauge of 50mm Square with 50 x
50 x 6 mm angles on either ends and with 2 Nos of MS flats
25 x 3mm on back to back and top and bottom and with
intermediate stiffiners with 2 Nos of MS flats 25 x 3 mm at
every 1m intervals including welding the weld mesh into the
frames with necessary consumables, preparation of
surface, necessary excavation to fix the post in the ground
and concreting the foundation of post with C.C. 1:3:6 - Sqm 120
610mm depth to a required size etc complete, as directed.
Rate shall include for supply and erection of welded mesh
fencing gate of 4500 mm wide and 1600mm height hinged
with necessary angle iron frame work at intervals as shown
in the drawing. Rate shall include for providing 2 coats of
sythetic enamel paint over a 1 coat of primer for structurel
member and weld mesh area and white washing 2 coats for
the RCC precast pole etc complete, as directed.

Total C/o.to Summary of 3 C in Rs..

C.R.Narayana Rao
Architects &Engineers 99 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

5.00 SEWAGE TRETMENT PLANT


5.01 Excavation in all types of soil including dense soil,
disintegrated/ weathered/ soft rock (Poclainable) for
Footings of columns, Retaining walls, etc., by mechanical
means to all depth including manual excavation for leveling,
dressing the edges, with all leads and lifts including back
filling in layers of 150mm with watering and compaction.
dewatering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
Cum 2000
of water with necessary shoring, struting, required for
keeping earth in position etc, Rate to include disposing the
excess earth and spreading in layers to the required levels
within the site wherever specified by the local authorities.
Only plan area of the base PCC will be considered for
measurement

5.02 Same as above item but for excavation in Hard rock /


boulders (more than 1/2 Cum in size -Un poclainable) by
chiseling/ wedging to required level at all depth for rafts,
retaining wall, catch pits, etc. to the required depth including
all leads and lifts, stacking excavated material within plot at
approved location and carting away unserviceable material
outside the site as directed, dressing, grading, cleaning, Cum 560
excavating loose pockets and compacting them after
backfilling as directed etc. as per detailed specification and
conforming to safety rules of Authority during the progress
of work. Only plan area of the base PCC will be considered
for measurement

5.03 Providing and laying plain cement concrete 1:4:8 using


coarse graded aggregate of 40 mm and down size for
levelling course under footings, steps, walls, platform etc.
including laying layers of specified thickness in alternative Cum 50
bays not exceeding 10 sqm as directed including form work
wherever necessary and well compacted etc. all complete,
as directed.
5.04 Providing and laying P.C.C. 1:3:6 of specified thick
wherever specified using river sand, 20mm and downsize
graded aggregate including base reperation, Compaction, Cum 10
levelling, all leads and lifts, curing and shuttering if
necessary etc., Complete
5.05 Providing, batching, mixing, transporting through transit
mixers, pumping and laying controlled Reinforced Cement
Concrete of specified grade at all levels and heights
specified below using ordinary Portland cement of grade 53
from approved manufacturer, river sand, 20mm and down
size coarse aggregates, necessary Mineral admixtures
approved by Consultants (elkem and Conplast SP 430SRV
from Fosroc or equivalent), including all leads and lifts,
pumping using line pump or boom placer, vibrating/
compaction, scaffolding wherever necessary, curing as
directed, excluding cost of shuttering and reinforcement
works.

C.R.Narayana Rao
Architects &Engineers 100 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

(Design mix shall be as approved by the Structural


Consultant / Employer's representatives

M30 Grade

a Base raft Cum 185


b Top slab Cum 90
c Platforms/lounders/Ledges/Haunches etc., Cum 25
d RC walls Cum 230
e Staircase Cum 5
f Columns and beams Cum 35
g Pedestals Cum 35
5.06 Providing, fabricating and erecting form work at all levels
and places wherever needed/specified as per drawing
including striking with 12mm Plastic coated, marine
resistant waterproof ply/Smooth finished MS plates with
adjustable steel props of acceptable Staging system and
with sufficient bracing as approved by consultant. Cost to
include designing of proper form work and staging system
to suit the requirements,Submission of design calculations
and shop drawings for approval,sealing the joints with
heavy duty brown self adhesive tape, aligning to line and
levels including M.S. Ties, PVC Spacer, Providing
openings/ cutouts/ pockets, applying deshuttering chemical,
Deshuttering as approved by the consultant etc., complete
at all levels, double/tripple heights and profiles for Note :
Only plan area shall be considered.No extra shall be paid
for Side shuttering of Drop panel/column capitals.

1) plywood shuttering shall be considered for all vertical


elements,beam
soffit,corewalls,stairs,ramps,tanks,RCCpedestals Etc.,
2) M.S. plates shall be considered for foundation,slabs
only.
3) Shuttering & deshuttering sequence shall be 100% ,80%
& 40% from the slab to be cast respectively

a Base raft Sqm 50


b Top slab Sqm 265
c Platforms/lounders/Ledges/Haunches etc., Sqm 100
d RC walls Sqm 1500
e Staircase Sqm 50
f Columns and beams Sqm 150
g Pedestals Sqm 150
5.07 Providing and fixing reinforcement for RCC work with
Thermo mechanically treated (TMT) bar of various
diameters and grade of steel as specified below conforming
to IS or equivalent BS specification including cutting and
waste, bending, hoisting, fabricating and placing in position
according to drawings and binding the reinforcement with
galvanised annealed binding wire of double fold of 18
gauge and providing PVC cover blocks for placing the
reinforcements in position and for maintaining the cover
specified and/or according to relevant IS or equivalent BS
code.

C.R.Narayana Rao
Architects &Engineers 101 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Note : Unless noted otherwise the measurements in


accordance with IS 1200 or equivalent BS. However
reinforcement shall be measured only in lengths of bars as
actually placed in position on standard weight basis, no
allowance being made in the weight for rolling margin.
Authorised laps and splices, Chairs of any shape & profile,
Spacer bar of any shape & profile, cover block, wastage
and binding wire will not be measured and shall be included
in the quoted rates.Quoted rate shall be deemed to have
considered the above stipulation.Quoted rate to include
lead, lift, placing at all levels and as directed. Detailing of
the reinforcement shall be ductile detailing for seismic
zone III as per codal requirement.

a Grade of reinforced steel - Fe 500


MT 100
5.08 Providing and fixing in position Hot rolled structural steel
Members / Sections at all levels and to any shape & profile
consisting of MS joists, channels, angles, purlins, runners,
insert plates, flats and sag rods with necessary sleeves,
bolts and nuts, gratings, pipes including cutting,
straightening, welding as per standards for connections
including consumables etc.complete. Rate shall include MT 2
preparation of surface, applying two coats of Zinc
chromate/Phosphate primer before and after erection and
two coats of first quality synthetic enamel paint of approved
make after erection, sand blasting etc. complete, as
directed.

5.09 Providing and fixing in position M.S.chequered plate 5mm


thick with necessary supports such as M.S. angles/M.S.
flats including stiffeners to be placed on angle iron frame
work. (Frame work, angles, stiffners will be measured under
relavent structural steel item). Rate shall include making
MT 1
necessary cutouts for inserts, applying one coat of Zinc
chromate/Phosphate primer and two coats of first quality
synthetic enamel paint of approved make etc complete,as
directed.

5.10 Providing and constructing cement concrete solid block


masonry work at all levels in cement mortar 1:3 using M -
5.5 Grade blocks of size 400 x 200 mm x 200 mm of solid
cement concrete blocks, .conforming to IS 2185 or
equivalent BS including all scaffolding, staging, curing, all
lifts etc. complete and as directed. Concrete blocks
manufactured under strict quality control conditions using
modern rugged block casting and stripping machine with
the latest moulding techniques etc. only shall be used.

I Solid block wall of 200 mm thick Sqm 125


ii Solid block wall of 100 mm thick Sqm 60

C.R.Narayana Rao
Architects &Engineers 102 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

5.11 Providing and fixing of hollow metal fire rated steel door 2
Hour / 1 Hour rating confirming to IS 3614 or Equivalent BS
and General purpose steel door at all levels with frames
and with fully flush type shutter having 48 mm thick made
out of Pressed Galvanised steel sheet confirming to IS 277,
(Coating shall be GLP grade Z 120 microns coating) to any
type, Size, Shape with various opening policy and of
System Schroders or approved equivalent make, but in
general the door consists of the following and the quoted
rate shall include the following :

a) Door Frame : Fabricated from galvanized steel sheet to


the profile and the thickness specified below :
i) Fire Door - 2 Hr rating : Double rebate profile of size 143
x 57 mm (+/- 0.3) with bending radius of 1.6 mm, using
galvanized steel sheet of 1.6 mm thick (16 Gauge).
ii) Fire Door - 1 Hr rating: Single rebate profile of size 100
x 57 mm (+/- 0.3) with bending radius of 1.4 mm, using
galvanized steel sheet of 1.20 mm thick (18 Gauge).
iii) General Purpose Door : Single rebate profile of size
100 x 57 mm (+/- 0.3) with bending radius of 1.4 mm, using
galvanized steel sheet of 1.20 mm thick (18 Gauge).

Frames shall be provided with the following :


i) Back plates - 3 mm thick on all jambs with provision for
anchor bolt fixing to wall openings.
ii) Hinge plates 3 mm thick pre-drilled to receive approved
type and make of hinges for screw mounted fixing.
iii) Factory finish-pre-punched cut outs to receive specified
type & make of hardware and iron mongery. All cut outs
including hinge plates, strike plates to have mortar guard
covers from inside to prevent cement, dust ingress into cut
outs at the time of grouting of the frame.
iv) Reinforcement pads for fixing of door closer, locks and
handles at appropriate location as per manufacturers
details.
v) Plug-in type rubber silencer not less than 2 mm dia shall
be provided on the strike jambs for single shutter frames
and on the head jambs for double shutter frames.
vi) Frames shall be in knock down form with butt joints for
bolted assembly at site or as per manufacturers
specification with out visible joints/welding marks in frames.

b) Door Shutter : Shutters should be press formed with


double skins to a total 48 mm thick hollow shutter with lock
seam joints at stile edges using galvanized steel sheet of
thickness specified below :
i) Fire Door - 2 Hour rating : 1.00 mm thick (16 Gauge).
ii) Fire Door - 1 Hour rating : 0.80 mm thick (19 Gauge).
iii) General Purpose Door : 0.80 mm thick (19 Gauge).

C.R.Narayana Rao
Architects &Engineers 103 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Shutters shall be provided with the following :


i) No visible screws or fasteners on either face and Internal
reinforcement shall be provided at top, bottom and stile
edges for desired fire rating.
ii) Factory prepared shutter with pre-punched cutouts and
reinforcement pads to receive the approved type and make
of Hardware and Iron mongery.
iii) Pre-drilled hinge plates with hinge guard covers and
shutters with locks to have concealed lock box with lock
fixing brackets with pre-tapped holes and screws.
iv) Reinforcement pad at appropriate location to receive the
locks, Door closer, Panic Bar, etc as per the approved type
and make of Hardware and all as per manufacturers design
and conforming to Standards.
v) Necessary provision / fixing arrangements shall be
provided in the shutter as well as in the frame to receive / fix
the Electro magnetic latch, Electro magnetic contact for
hooter with reinforcement pads and in such a way to
connect the same to the card access control system / IBMS.

c) Infil material: Honeycomb paper core as infill material


and to be bounded to the inner faces of the shutter or as
per Manufacturers specification. Door should have been
tested with Infill material proposed by the manufacturer and
the same should have been approved by CBRI / BFRC.

d) Finish: Surface of the frame and shutter shall be


cleaned suitably & thoroughly with solvents and as per
manufacturers specification. Apply Zinc etch primer coating
as shop coat to receive additional coat of primer and top
coats, apply stove zinc phosphate primer (35 microns DFT)
as additional coat and finish the surface neatly with thermo
setting polyurethane paint (35 microns DFT) of approved
colour and make.
e) Installation : The frame and shutter shall be installed in
position as per the methdology described in the Technical
specification with necessary accessaries, tools & Plants etc.

f) Grouting: Frame shall be pressure grouted with cement


slurry 1:3 ratio or filling the pre cast solid block core to the
frame profile as approved. The surface after grouting shall
be neatly cleaned and to be ensured that there is no
scratch in the door frames after grouting.Back fill the frame
through holes provided and insert plug in type nylon plugs
after cleaning the surface and to suit the frame finish and
colour.

C.R.Narayana Rao
Architects &Engineers 104 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

G) Hardwares :
i) Vision panel : Providing and fixing Borosilicate single
clear toughened glass of Pyron or approved equivalent
make to the thickness of 6 mm to with stand two hours fire
rating including making cutouts in the steel door & fixing in
position with spin turned rings. Rate shall include for
providing one side adhesive Glazing tape in the frame to
hold the vision panel glass in position and to ensure the
stability of the fixing. One vision panel shall be provided in
the active leaf of the Single / Double leaf shutter.
ii) Hinge : Providing and fixing Stainless steel satin finish
double ball bearing butt hinges with SS screws of size 100
x 75 x 3 mm thick - Model No. SS 551 B - class 8 / 9 from
Dorma or approved equivalent make suitably for Single /
Double leaf door. Stainless steel conforming to SS 316 L
grade to BS 7352 or BS EN 1935-2002. 4 Nos for Single
Leaf Shutter and 8 Nos for Double Leaf Shutter.
ii) Flush Bolt : Providing and fixing Stainless steel satin
finish consealed tower bolt with SS screws of approved
equivalent make for Double leaf door in the In - Active leaf.

H) Provision :
i) Provision / fixing arrangements to be made in the shutter
as well as in the frame to receive / fix the Hinges, Locks,
Electro magnetic latch, Electro magnetic contact for hooter
with reinforcement pads and in such a way to connect the
same to the card access control system / IBMS.
ii) Refer hardware schedule enclosed for the details of
Mortise sash lock, Mortise dead lock, Handles, Push plates
and Panic bar etc. Necessary provision shall be made in
the frame and shutter to receive and fix the hardwares.
iii) Supplying Master key for the doors either floor wise or
wing wise as per the Master key plan including supplying
Grand Master key for all the doors.

Note :
1. All the Materials and hardware specifications proposed
for door shall conform to the codes, technical specification
and preamble to the bills of quantities.
2. Quoted rate shall be deemed to have considered all the
items covered in the specification and drawings, whether
explicitly stated or not.

Fire Rated Steel - 1 Hr Rating


Single Leaf door Sqm 5

C.R.Narayana Rao
Architects &Engineers 105 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

5.12 Providing and fixing aluminium fixed cum sliding windows


fabricated as per drawing and fixed at all levels, elevations
and heights having a main frame work of vertical and
horizontals, out of specially designed approved extruded
sections to withstand the designed wind pressure and
loads. The extruded section shall be finished with
electrolylic colour anodised of approved colour with anodic
coating not less than 20 microns and the extruded
aluminium sections shall be of 6063 Alloy or BSH9
conforming to IS 63400.

Rate shall include to fix the main frames into masonry wall /
RC concrete surface with necessary clamps, fastening
straps, nuts, bolts, rivets, washers and other fastening
materials shall be in stainless steel or aluminium. Rate
shall include for providing clear toughened glass 6 mm
thick and to be fixed with snap fit aluminium beading section
and special water proof EPDM Gasket, Neoprene etc. -
complete. Necessary silicon sealant of Dowcorning 991 HP
or Non Bleeding Sealant of GE silicon or approved
equivalent make shall be provided at the junctions between
wall and main frames.

Rate shall include stainless steel safety clips to be


provided on each corner of glass as an additional
safety to avoid breakage of corner of the glass and also
to be provided with EPDM / Neoprene tripple barrier,
extruded Reddiprone weather strip to ensure water and Sqm 5
air tightness and shall include to conduct the performance
test conforming to IS Specification, etc. complete all as
directed.
5.13 Plastering of walls with cement mortar 1:4, 15 mm thick with
a neat floating coat of cement for smooth finish according to
specifications. Rate shall include for providing G.I.chicken
mesh made out of galvanised iron of nominal thickness
0.35 mm with a Zinc coating of 120 gms per Sqm at the
junctions of masonry and concrete works to a width of 100 Sqm Qro
to 125mm including tying in position with suitable
clamps/screws,necessary staging,scafolding and curing at
all levels and elevations etc.complete as directed.

5.14 Plastering of R.C walls, peripheral beams and columns with


CM 1:3, 12 mm thick with a neat floating coat of cement for
smooth finish according to the specification. Rate shall
include for providing G.I.chicken mesh made out of
galvanised iron of nominal thickness 0.35 mm with a Zinc
coating of 120 gms per Sqm at the junctions of masonry Sqm 950
and concrete works to a width of 100 to 125mm including
tying in position with suitable clamps/screws,necessary
staging,scafolding and curing at all levels and elevations
etc.complete as directed.

C.R.Narayana Rao
Architects &Engineers 106 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

5.15 Providing 20 mm thick water proof plaster to tanks in C.M


1:3, finished smooth with a floating coat of neat cement
using CICO No: 1 or approved water proofing compound
by weight to the required percentage as per Manufacturers Sqm 100
specification and as directed.

5.16 Providing three coats of 'ACRYLIC Emulsion Paint to walls


of approved colour over a coat of water based primer
including preparation of surface by thorough cleaning and
wetting and applying POP/Gypsum powder putty as per Sqm 560
manufacturers specification fully to give an even shade
before painting and curing as per manufacturers
specifications and as directed.
5.17 Plastering of ceiling including slabs, beams and column
drops and staircase waist slabwith CM 1:3, 6 mm thick with
a neat floating coat of cement for smooth finish according to
the specification. The rate shall include necessary Sqm 250
scaffolding, form work and curing etc. complete all as
directed.

5.18 Plastering for external surfaces with base coat of 20 mm


thick in C.M 1:4 with water proofing compound of CICO
No.1 or equivalent as per Manufacturer's Specification and
finishing coat of 10 mm thick in C.M 1:3 after roughening
the surface of first coat in green condition with wire brush
and clearing of loose particles with sponge finish (washed Sqm 560
sand finish) all complete as per specification and as
directed. Rate shall include for providing drip bands /
moulds / grooves to any size and shape as directed.

5.19 Applying white washing three coats to ceilings and walls


with pure shell lime or fat lime conforming to IS-712 all as
per Specification and as directed. For shaft , lift interior Sqm 250
walls.

5.20 Providing two coats of first quality water proof cement paint
of approved make and colour over a priming coat of white
colour water proof cement paint or any primer specified by
the manufacturer including preparation of surface by Sqm 950
thorough cleaning and wetting before painting and curing all
as per manufacturer`s specifications and as directed.

5.21 Treatment on PCC levelling course below base slab,


Junctions of side walls and base slab of Sewage
treatment plant etc. covering the following sequence of
operation :
a) Providing, supplying, mixing, laying cement screed
plaster 20 mm thick in cement concrete slurry 1:2:4 mixed
with 6mm & down grade course graded aggregate with
water proofing compound like CICO NO:1 (normal setting
integral water proofing compound) or approved equivalent
conforming to IS at the rate specified by the manufacturer
over PCC levelling course at any depth & height.

C.R.Narayana Rao
Architects &Engineers 107 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

b) Providing, supplying, mixing, applying two coats of ready


to use two component Acrylic polymer modified cement
based, flexible, water proofing slurry like TAPECRETE or
approved equivalent to a thickness of 2 mm over the
plastered surface of operation above.
c) Providing and laying water proofing treatment with
Membrane type water proofing methods using polymer
modified Bituminous membrane of CICO shield /Build
Wrap/ Deboer make or approved equivalent make. The
Atactic Poly-Propylene (APP) membrane shall have UV
resistant property, ground chemical resistant, high melting
points, flexible and elastic with high adhesive strength. The
membrane shall be reinforced with non woven polyester
reinforcement of minimum of 180 g/sqm and reinforced with
glass fibre grill of 8 g/sqm including coating with compatible
primer of Bituminous base whereever it is required and
torch application with overlap of 70 - 100 mm wherever
required. Cost to include laying by loose and torching the
prefabricated overlap at ends. The membrane surface shall
be procted with granules.

d) Providing, supplying, mixing, laying cement concrete


screed 40 mm thick with CC slurry 1:2:4 mixed with 12mm &
down grade course graded aggregate with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth & height.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 320
plants, mixing device and gauge,Shuttering etc.complete as
per manufacturer's specification and as directed.

5.22 Providing chemical injection in the form of pressure grouting


to the base slab,and side walls of STP from interior
surfaces works at any depth, height and level by injecting
cement slurry mixed with grout with CICO non shrink
grouting compound or approved equivalent admixed with
cement slurry in the required consistency through the
prefixed GI nozzles in the 18mm dia holes drilled in grid
pattern at a spacing not exceeding 1 metre c/c on the top of
base slab/retaining wall & surfaces under pressure using
grout pump. Nozzle fixing and grouting for a retaining wall
shall be only at construction joints and honeycomb areas on
approval.

C.R.Narayana Rao
Architects &Engineers 108 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Rate shall include for preparation of surface, de-watering,


drilling holes, using pneumatic hammer for fixing of GI
nozzles to the required depth, grouting admixture and finally
cutting the projected nozzles and sealing of the GI nozzles
after injection operation is over with CICO NO:3 quick
setting material or approved equivalent admixed with
cement, finishing, curing, etc., as per manufacturers
specification. Rate shall include for preparation of surface
by mechanical upgrading to remove all loose mortar and
laitance, oil, grease etc. and washing the surface with water
to get neat surface, dewatering, finishing, curing,
scaffolding, waterproofing chemicals, wastage,
conveyance, tools and plants, mixing device and gauge,
shuttering, Nozzles etc. complete as per manufacturer's
specification and as directed.

Mode of measurement:

Note : Item no. a) Top of raft slab of basement lift pit base
slab and UG sump base slab ie. width and length between
the retaining wall only will be measured and paid for.

Note : Item no. b) Grouting carried out on the vertical


surfaces(Internal) of the Retaining wall of the basement, lift
pit & UG sump will be measured and paid for.

a Raft slab & lift pits Sqm 300


b Retaining walls of basement Sqm 520
5.23 Treatment to side wall of varying thickness of STP from
exterior surface covering the following sequence of
operations :
a) Providing, supplying, mixing, applying two coats of ready
to use two component acrylic polymer modified cement
based flexible water proofing slurry like TAPECRETE or
approved equivalent conforming to IS to thickness of 2
mm on the surface of side wall prior to the chemical
injection treatment is completed as specified under item
above.

b) Providing and laying water proofing treatment with


Membrane type water proofing methods using polymer
modified Bituminous membrane of CICO shield /Build
Wrap/ Deboer make or approved equivalent make. The
Atactic Poly-Propylene (APP) membrane shall have UV
resistant property, ground chemical resistant, high melting
points, flexible and elastic with high adhesive strength. The
membrane shall be reinforced with non woven polyester
reinforcement of minimum of 180 g/sqm and reinforced with
glass fibre grill of 8 g/sqm including coating with compatible
primer of Bituminous base whereever it is required and
torch application with overlap of 70 - 100 mm wherever
required. Cost to include laying by loose and torching the
prefabricated overlap at ends. The membrane surface shall
be procted with granules.

C.R.Narayana Rao
Architects &Engineers 109 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

c) Providing and laying solid block 150mm thick using


cement mortar 1:3 with 75mm thick RC band @ every 1m
intervals with nominal reinforcements of 3 Nos of 8mm dia,
over the APP membrane as directed.

d) Providing, supplying, mixing, laying cement plaster 15


mm thick with cement mortar 1:4 mixed with approved water
proofing compound like CICO NO:1 or equivalent
conforming to IS at the rate specified by the manufacturer
over the coated surface of operation specified in point no.
(a) above.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 520
plants, mixing device and gauge, shuttering, Nozzles etc.
complete as per manufacturer's specification and as
directed.

5.24 Treatment on junctions of base slab & wall and side walls
in STP internal surfaces etc. covering the following
sequence of operation:

a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)

b) Providing, supplying, mixing, applying two coats of ready


to use two component Acrylic polymer modified cement
based, flexible, water proofing slurry like TAPECRETE or
approved equivalent to a thickness of 2 mm over the
plastered surface of operation above.
c) Providing, supplying, mixing, laying cement plaster 15
mm thick with cement mortar 1:4 mixed with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth below finished floor level.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 520
plants, mixing device and gauge, shuttering, etc. complete
as per manufacturer's specification and as directed.

C.R.Narayana Rao
Architects &Engineers 110 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

5.25 Water proofing treatment Treatment over RCC roof slab laid
to slope in terrace and gutter slab covering the following
sequence of operation and specifications:
a) The roof slab laid in slope / gutter slab shall be
thoroughly cleaned by removing the debris and dust, to
receive the water proofing treatment.

a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)

c) Applying 2 coats of acrylic polymer modified cement


based, flexible water proofing slurry like TAPECRETE or
approved equivalent make to a thickness of 2mm and cured
for 7 days and as per manufacturer's specification.

d) Supplying, providing and applying water proofing


treatment with Membrane type water proofing methods
using polymer modified Bituminous membrane of CICO
shield/ Build Wrap/ Deboer or approved equivalent make.
The Atactic Poly-Propylene (APP-4mm th)membrane
having UV resistant, ground chemical resistant, high melting
point more than 110 deg. C, flexible and elastic with high
adhesive strength. The membrane shall be reinforced with
non woven polyester reinforcement of minimum of 180
g/sqm and reinforced including coating with compatible
primer of Bituminous base and torch application with
overlap of 100 mm wherever required. The reinforcement
provided shall be able to withstand the traffic flow density
during & after construction and shall carry a minimum
guarantee period of 10 years. Cost to include applying the
primer and torching the entire surface and also
prefabricated overlap at ends. The membrane surface shall
be protected with granules.

C.R.Narayana Rao
Architects &Engineers 111 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

e) Providing, supplying & laying extruded polystyrene rigid


foam panel of size600 x 1200mm-75mm thick of formula
R.Metric-FM 50 having a density of 24 kg/cum and
compressive strength not less than 250 kpa of ownes
corning or approved equivalent make having exeptional
mechanical properties like resistance to the diffusion of
water vapour, resistance to water absorption, uniform
density distribution, dimensional stability, very high
compressive strength, aging resistance and also immunity
against insects, pets, bacteria, rodent attacks and micro
organisms etc., for over deck insulation including necessary
skin shiplap joint,anchores,adhesives, primers etc., as
required for proper fixing etc., complete all as per the
manufacturers specifications & consultants approval. The
extruded polystyrene panel has closed sealed cells
structure linked to one another is produced by a contineous,
fully automated extrusion process in accordance with
international specification and standard etc. all complete.

f) Laying fibre glass cloth over the extruded polystyrene


rigid foam panel.

g) A layer of 20 mm thick cement mortar 1:4 admixed with


CICO NO - 1 (normal setting integral water proofing
compound) or other approved equivalent make compound
shall be spread over the operation specified in point (f)
above and laying brickbat coba over the surface 40mm
thickness at drain point and required thickness at ridge and
the top surface of the brickbat coba shall be plastered with
cement mortar 1:4, 20 mm thick admixed with CICO NO:1
@ 2% by the weight of cement and add RECRON 3S 225
per bag of cement and draw false line of 300 mm X 300 mm
over the finished surface. (The rate shall be quoted for an
average thickness of 110 mm).

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface,dewatering, finishing, curing, scaffolding, supply
and adding water proofing chemicals at the specified
proportion as per manufacturer's specifications, all
materials, wastages, conveyance, tools and plants, mixing Sqm 280
device and gauge, shuttering and also include for
conducting leakage test at terrace by storing water on the
terrace for about 25 mm depth continuously for a period of 7
days etc.complete, as directed.

5.26 Extra rate over and above item no (25 g) above, for
Providing and laying brickbat coba using well burnt brick
bats set in cement mortar 1:3 by adding CICO no.1or Cum Qro
approved equivalent water proofing compound including
curing etc complete as directed

C.R.Narayana Rao
Architects &Engineers 112 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

5.27 Providing & fixing of MS handrail 1000mm clear height of


size 32mm dia as verticals at 900mm c/c firmly fixed to the
R.C. steps welded with 75x75x6mm ms insert plate with
necessary lugs and providing of 2Nos. of 32mm dia ms
pipes as horizontals at equal distance should be welded Rmt 125
with verticals by 25 dia ms pipe including necessary tools
and plants required etc. complete including one coat of
primer and two coats of paint.

5.28 Providing, and drilling/core cutting of required dia.outlets


using low vibration,mechanical means drilling equipments
of aproved makes as directed by the engineer in charge
.cost to include identification of embeded reinforcement
using profometer,closing of corecut using self sealing, non
shrink grouts of approved makes either single or double
component with necessary formwork, staging, tools, etc.,
complete up to 300 mm depth

(i) 50mm Dia No. 5


(ii) 100mm Dia No. 5
(iii) 150mm Dia No. 2
iv) 200mm Dia No. 2
v) 230 mm Dia No. 5
vi) 300 mm Dia No. 2
5.29 Supplying and fixing Heavy duty CI manhole cover and
frame of " NECO" make,cover weighing not lesser than the
following and being a size of 600 x 600 mm, including
painting with two coats of anticorrosive paint over a coat of
primer etc. Rate shall include providing and fixing locking
arrangements, fixing the Man-hole cover, grouting the
anchors with C.C 1:2:4 as per specification and as
directed.

a Weight Not less than 50 Kg. Nos 1


5.30 Supplying and fixing G.I.Puddle Flanges of various dia and
size made out of G.I with screwed ends, cap and plates for
embedment in concrete as necessary with suitable
accessories, consumables welding accessories including
placing in position, grouting, making necessary provision in
the centering & shuttering etc, including one coat of zinc
rich primer complete and as directed.
A 50mm to 80mm dia
I Between 300 & 600 mm long Each 2
ii. Between 601 & 1200 mm long Each 2
B 100mm to 150 dia
I Between 300 & 600 mm long Each 2
ii. Between 601 & 1200 mm long Each 2
C 200 mm to 250mm dia
I Between 300 & 750 mm long Each 2
ii. Between 751 & 1500 mm long Each 2

C.R.Narayana Rao
Architects &Engineers 113 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

D 300mm to 350mm dia


I Between 300 & 750 mm long Each Qro
ii. Between 751 & 1500 mm long Each Qro
5.31 Supplying and fixing poly-propelene rungs of 20 mm square
bar of size 263 x 165 mm for access way including
anchorage in walls to a minimum depth of 100 mm with C.C Nos 100
1:2:4 etc. complete and as directed.

5.32 Providing, and Fixing of required dia.pipe sleeves of


approved makes as directed by the engineer in charge .cost
to include identification of positions,placing and tying with
reinforcement using MS hold fasts,tie rods,sealing of ends
with necessary formwork, staging, tools, etc., complete

a 150mm dia Nos 2


b 100mm dia Nos 2
c 80 mm dia Nos 2
d 50 mm dia Nos 2
5.33 Supplying and fixing PVC coated chain link fencing as per
drawings consisting of the following:

Earthwork excavation in all kinds of soils and soft


disintegrated rock for pits of size 750 x 750 x 750 mm
(depth below natural ground level at the location) for
foundation for RCC vertical posts at 2.40 M (may vary
slightly to site condition) centre-to-centre and strut posts at
every 7th vertical post on both sides and at corners on both
sides including levelling, ramming the bottom, de-watering,
disposing of the excavated material at places shown etc.
and as directed.

Providing and laying plain cement concrete 1:4:8 using 40


mm and below size hard broken stone in the above
mentioned pits after erecting the vertical and strut posts in
position including ramming, curing etc. all complete.

Manufacturing 2.70 m long RCC vertical tapered posts of


size 175 x 175 mm at bottom and 175 x 125 mm at top in
M15 grade cement concrete using 20 mm and below size
hard broken stone with 4 Nos. 12 mm dia. tor steel and 6
mm dia. MS stirrups at 125 mm centre-to-centre as
reinforcement at 2.40 M C/c keeping the bottom 600 mm in
foundation concrete etc.

Manufacturing 2.10 M long RCC strut posts of size 125 x


125 mm in M15 grade cement concrete using 20 mm and
below size hard broken stone with 4 Nos. 10 mm dia tor
steel and 6 mm dia MS stirrups at 125 mm c/c as
reinforcement and fixing the strut post in position at every
7th post on both sides and at corners on both sides in
foundations concrete.

Supplying and fixing 2.10 M long 50 x 6 mm size MS flat on


each vertical post with 3 Nos. 12 mm dia bolt washer and
nut.

C.R.Narayana Rao
Architects &Engineers 114 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Supplying and fixing 10 gauge 75 x 75 mm size GI chain


link fencing to 2.10 M high above ground level supported on
vertical post and flat and tied with 20 G - GI binding wire
and stiffened the fencing with 3 rows (one at top, one at
bottom and one at middle) 10 G - GI barbed wire along the
fencing.
Painting the flat with one coat of red oxide primer and two
coats of synthetic enamel anti-corrosive paint of approved
make and shade.

The entire work shall be carried out as per specifications


and drawings including cost of all materials, labour, form
work, reinforcement, fabrication, painting, wastage, curing, RM 50
tools and plant etc. all complete and as directed.

Total C/o.to Summary of 3 C in Rs..

6.00 UNDERGROUND SUMP WORKS

6.01 Excavation in all types of soil including dense soil,


disintegrated/ weathered/ soft rock (Poclainable) for
Footings of columns, Retaining walls, etc., by mechanical
means to all depth including manual excavation for leveling,
dressing the edges, with all leads and lifts including back
filling in layers of 150mm with watering and compaction.
dewatering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free Cum 3320
of water with necessary shoring, struting, required for
keeping earth in position etc, Rate to include disposing the
excess earth and spreading in layers to the required levels
within the site wherever specified by the local authorities.
Only plan area of the base PCC will be considered for
measurement.

6.02 Supply and filling in foundations with approved good quality


filling materials wherever specified in layers of not
exceeding 150 mm thick including breaking
clods,storing,transportation, handling, watering, compacting
each layer with vibratory compactor and at unaccessible
places with wooden/steel rammers to achieve 90 to 95%
proctor density at optimum moisture content, all leads and -
lifts, bailing/ pumping out of water to keep site dry while
backfilling; cost shall include conveyance of all materials,
labour, machinery etc. complete as directed.The rate to
include loading,unloading, hire and fuel charges for tools
and plants and other incidental charges etc., complete.

a Approved quality river sand brought from outside Cum 105


b With approved quality quarrydust brought from outside Cum 50

C.R.Narayana Rao
Architects &Engineers 115 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.03 Providing and laying P.C.C. 1:3:6 of specified thick


wherever specified using river sand, 20mm and downsize
graded aggregate including base reperation, Compaction,
Cum 105
levelling, all leads and lifts, curing and shuttering if
necessary etc., Complete

6.04 Providing, batching, mixing, transporting through transit


mixers, pumping and laying controlled Reinforced Cement
Concrete of specified grade at all levels and heights
specified below using ordinary Portland cement of grade 53
grade 43 from approved manufacturer, river sand, 20mm
and down size coarse aggregates, necessary Mineral
admixtures approved by Consultants (elkem and Conplast
SP 430SRV from Fosroc or equivalent), including all leads
and lifts, pumping using line pump or boom placer,
vibrating/ compaction, scaffolding wherever necessary,
curing as directed, excluding cost of shuttering and
reinforcement works.

(Design mix shall be as approved by the Structural


Consultant / Employer's representatives

M30 Grade

a Base raft Cum 420


b Top slab Cum 190
c Platforms/lounders/Ledges/Haunches etc., Cum 20
d RC walls Cum 200
e Staircase Cum 5
f Columns and beams Cum 25
g Pedestals Cum 25
6.05 Providing, fabricating and erecting form work at all levels
and places wherever needed/specified as per drawing
including striking with 12mm Plastic coated, marine
resistant waterproof ply/Smooth finished MS plates with
adjustable steel props of acceptable Staging system and
with sufficient bracing as approved by consultant. Cost to
include designing of proper form work and staging system
to suit the requirements,Submission of design calculations
and shop drawings for approval,sealing the joints with
heavy duty brown self adhesive tape, aligning to line and
levels including M.S. Ties, PVC Spacer, Providing
openings/ cutouts/ pockets, applying deshuttering chemical,
Deshuttering as approved by the consultant etc., complete
at all levels, double/tripple heights and profiles for Note :
Only plan area shall be considered.No extra shall be paid
for Side shuttering of Drop panel/column capitals.

C.R.Narayana Rao
Architects &Engineers 116 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

1) plywood shuttering shall be considered for all vertical


elements,beam
soffit,corewalls,stairs,ramps,tanks,RCCpedestals Etc.,
2) M.S. plates shall be considered for foundation,slabs
only.
3) Shuttering & deshuttering sequence shall be 100% ,80%
& 40% from the slab to be cast respectively

a Base raft Sqm 75


b Top slab Sqm 620
c Platforms/lounders/Ledges/Haunches etc., Sqm 100
d RC walls Sqm 1350
e Staircase Sqm 50
f Columns and beams Sqm 150
g Pedestals Sqm 100
6.06 Providing and fixing reinforcement for RCC work with
Thermo mechanically treated (TMT) bar of various
diameters and grade of steel as specified below conforming
to IS or equivalent BS specification including cutting and
waste, bending, hoisting, fabricating and placing in position
according to drawings and binding the reinforcement with
galvanised annealed binding wire of double fold of 18
gauge and providing PVC cover blocks for placing the
reinforcements in position and for maintaining the cover
specified and/or according to relevant IS or equivalent BS
code.

Note : Unless noted otherwise the measurements in


accordance with IS 1200 or equivalent BS. However
reinforcement shall be measured only in lengths of bars as
actually placed in position on standard weight basis, no
allowance being made in the weight for rolling margin.
Authorised laps and splices, Chairs of any shape & profile,
Spacer bar of any shape & profile, cover block, wastage
and binding wire will not be measured and shall be included
in the quoted rates.Quoted rate shall be deemed to have
considered the above stipulation.Quoted rate to include
lead, lift, placing at all levels and as directed. Detailing of
the reinforcement shall be ductile detailing for seismic
zone III as per codal requirement.

a Grade of reinforced steel - Fe 500 MT 145

C.R.Narayana Rao
Architects &Engineers 117 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.07 Providing and fixing in position Hot rolled structural steel


Members / Sections at all levels and to any shape & profile
consisting of MS joists, channels, angles, purlins, runners,
insert plates, flats and sag rods with necessary sleeves,
bolts and nuts, gratings, pipes including cutting,
straightening, welding as per standards for connections
including consumables etc.complete. Rate shall include MT 2
preparation of surface, applying two coats of Zinc
chromate/Phosphate primer before and after erection and
two coats of first quality synthetic enamel paint of approved
make after erection, sand blasting etc. complete, as
directed.

6.08 Providing and fixing in position M.S.chequered plate 5mm


thick with necessary supports such as M.S. angles/M.S.
flats including stiffeners to be placed on angle iron frame
work. (Frame work, angles, stiffners will be measured under
relavent structural steel item). Rate shall include making
MT 1
necessary cutouts for inserts, applying one coat of Zinc
chromate/Phosphate primer and two coats of first quality
synthetic enamel paint of approved make etc complete,as
directed.

6.09 Providing and constructing cement concrete solid block


masonry work at all levels in cement mortar 1:3 using M -
5.5 Grade blocks of size 400 x 200 mm x 200 mm of solid
cement concrete blocks, .conforming to IS 2185 or
equivalent BS including all scaffolding, staging, curing, all
lifts etc. complete and as directed. Concrete blocks
manufactured under strict quality control conditions using
modern rugged block casting and stripping machine with
the latest moulding techniques etc. only shall be used.

I Solid block wall of 200 mm thick Sqm 100


ii Solid block wall of 100 mm thick Sqm 50
6.10 Providing and fixing of hollow metal fire rated steel door 2
Hour / 1 Hour rating confirming to IS 3614 or Equivalent BS
and General purpose steel door at all levels with frames
and with fully flush type shutter having 48 mm thick made
out of Pressed Galvanised steel sheet confirming to IS 277,
(Coating shall be GLP grade Z 120 microns coating) to any
type, Size, Shape with various opening policy and of
System Schroders or approved equivalent make, but in
general the door consists of the following and the quoted
rate shall include the following :

C.R.Narayana Rao
Architects &Engineers 118 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

a) Door Frame : Fabricated from galvanized steel sheet to


the profile and the thickness specified below :
i) Fire Door - 2 Hr rating : Double rebate profile of size 143
x 57 mm (+/- 0.3) with bending radius of 1.6 mm, using
galvanized steel sheet of 1.6 mm thick (16 Gauge).
ii) Fire Door - 1 Hr rating: Single rebate profile of size 100
x 57 mm (+/- 0.3) with bending radius of 1.4 mm, using
galvanized steel sheet of 1.20 mm thick (18 Gauge).
iii) General Purpose Door : Single rebate profile of size
100 x 57 mm (+/- 0.3) with bending radius of 1.4 mm, using
galvanized steel sheet of 1.20 mm thick (18 Gauge).

Frames shall be provided with the following :


i) Back plates - 3 mm thick on all jambs with provision for
anchor bolt fixing to wall openings.
ii) Hinge plates 3 mm thick pre-drilled to receive approved
type and make of hinges for screw mounted fixing.
iii) Factory finish-pre-punched cut outs to receive specified
type & make of hardware and iron mongery. All cut outs
including hinge plates, strike plates to have mortar guard
covers from inside to prevent cement, dust ingress into cut
outs at the time of grouting of the frame.
iv) Reinforcement pads for fixing of door closer, locks and
handles at appropriate location as per manufacturers
details.
v) Plug-in type rubber silencer not less than 2 mm dia shall
be provided on the strike jambs for single shutter frames
and on the head jambs for double shutter frames.
vi) Frames shall be in knock down form with butt joints for
bolted assembly at site or as per manufacturers
specification with out visible joints/welding marks in frames.

b) Door Shutter : Shutters should be press formed with


double skins to a total 48 mm thick hollow shutter with lock
seam joints at stile edges using galvanized steel sheet of
thickness specified below :
i) Fire Door - 2 Hour rating : 1.00 mm thick (16 Gauge).
ii) Fire Door - 1 Hour rating : 0.80 mm thick (19 Gauge).
iii) General Purpose Door : 0.80 mm thick (19 Gauge).

C.R.Narayana Rao
Architects &Engineers 119 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Shutters shall be provided with the following :


i) No visible screws or fasteners on either face and Internal
reinforcement shall be provided at top, bottom and stile
edges for desired fire rating.
ii) Factory prepared shutter with pre-punched cutouts and
reinforcement pads to receive the approved type and make
of Hardware and Iron mongery.
iii) Pre-drilled hinge plates with hinge guard covers and
shutters with locks to have concealed lock box with lock
fixing brackets with pre-tapped holes and screws.
iv) Reinforcement pad at appropriate location to receive the
locks, Door closer, Panic Bar, etc as per the approved type
and make of Hardware and all as per manufacturers design
and conforming to Standards.
v) Necessary provision / fixing arrangements shall be
provided in the shutter as well as in the frame to receive / fix
the Electro magnetic latch, Electro magnetic contact for
hooter with reinforcement pads and in such a way to
connect the same to the card access control system / IBMS.

c) Infil material: Honeycomb paper core as infill material


and to be bounded to the inner faces of the shutter or as
per Manufacturers specification. Door should have been
tested with Infill material proposed by the manufacturer and
the same should have been approved by CBRI / BFRC.

d) Finish: Surface of the frame and shutter shall be


cleaned suitably & thoroughly with solvents and as per
manufacturers specification. Apply Zinc etch primer coating
as shop coat to receive additional coat of primer and top
coats, apply stove zinc phosphate primer (35 microns DFT)
as additional coat and finish the surface neatly with thermo
setting polyurethane paint (35 microns DFT) of approved
colour and make.

e) Installation : The frame and shutter shall be installed in


position as per the methdology described in the Technical
specification with necessary accessaries, tools & Plants etc.

f) Grouting: Frame shall be pressure grouted with cement


slurry 1:3 ratio or filling the pre cast solid block core to the
frame profile as approved. The surface after grouting shall
be neatly cleaned and to be ensured that there is no
scratch in the door frames after grouting.Back fill the frame
through holes provided and insert plug in type nylon plugs
after cleaning the surface and to suit the frame finish and
colour.

C.R.Narayana Rao
Architects &Engineers 120 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

G) Hardwares :
i) Vision panel : Providing and fixing Borosilicate single
clear toughened glass of Pyron or approved equivalent
make to the thickness of 6 mm to with stand two hours fire
rating including making cutouts in the steel door & fixing in
position with spin turned rings. Rate shall include for
providing one side adhesive Glazing tape in the frame to
hold the vision panel glass in position and to ensure the
stability of the fixing. One vision panel shall be provided in
the active leaf of the Single / Double leaf shutter.
ii) Hinge : Providing and fixing Stainless steel satin finish
double ball bearing butt hinges with SS screws of size 100
x 75 x 3 mm thick - Model No. SS 551 B - class 8 / 9 from
Dorma or approved equivalent make suitably for Single /
Double leaf door. Stainless steel conforming to SS 316 L
grade to BS 7352 or BS EN 1935-2002. 4 Nos for Single
Leaf Shutter and 8 Nos for Double Leaf Shutter.
ii) Flush Bolt : Providing and fixing Stainless steel satin
finish consealed tower bolt with SS screws of approved
equivalent make for Double leaf door in the In - Active leaf.

H) Provision :
i) Provision / fixing arrangements to be made in the shutter
as well as in the frame to receive / fix the Hinges, Locks,
Electro magnetic latch, Electro magnetic contact for hooter
with reinforcement pads and in such a way to connect the
same to the card access control system / IBMS.
ii) Refer hardware schedule enclosed for the details of
Mortise sash lock, Mortise dead lock, Handles, Push plates
and Panic bar etc. Necessary provision shall be made in
the frame and shutter to receive and fix the hardwares.
iii) Supplying Master key for the doors either floor wise or
wing wise as per the Master key plan including supplying
Grand Master key for all the doors.

Note :
1. All the Materials and hardware specifications proposed
for door shall conform to the codes, technical specification
and preamble to the bills of quantities.
2. Quoted rate shall be deemed to have considered all the
items covered in the specification and drawings, whether
explicitly stated or not.
Fire Rated Steel - 1 Hr Rating
Single Leaf door Sqm 5
b. Double Leaf Sqm Qro

C.R.Narayana Rao
Architects &Engineers 121 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.11 Providing and fixing aluminium fixed cum sliding windows


fabricated as per drawing and fixed at all levels, elevations
and heights having a main frame work of vertical and
horizontals, out of specially designed approved extruded
sections to withstand the designed wind pressure and
loads. The extruded section shall be finished with
electrolylic colour anodised of approved colour with anodic
coating not less than 20 microns and the extruded
aluminium sections shall be of 6063 Alloy or BSH9
conforming to IS 63400.

Rate shall include to fix the main frames into masonry wall /
RC concrete surface with necessary clamps, fastening
straps, nuts, bolts, rivets, washers and other fastening
materials shall be in stainless steel or aluminium. Rate
shall include for providing clear toughened glass 6 mm
thick and to be fixed with snap fit aluminium beading section
and special water proof EPDM Gasket, Neoprene etc. -
complete. Necessary silicon sealant of Dowcorning 991 HP
or Non Bleeding Sealant of GE silicon or approved
equivalent make shall be provided at the junctions between
wall and main frames.

Rate shall include stainless steel safety clips to be


provided on each corner of glass as an additional
safety to avoid breakage of corner of the glass and also
to be provided with EPDM / Neoprene tripple barrier,
extruded Reddiprone weather strip to ensure water and Sqm 5
air tightness and shall include to conduct the performance
test conforming to IS Specification, etc. complete all as
directed.

6.12 Plastering of walls with cement mortar 1:4, 15 mm thick with


a neat floating coat of cement for smooth finish according to
specifications. Rate shall include for providing G.I.chicken
mesh made out of galvanised iron of nominal thickness
0.35 mm with a Zinc coating of 120 gms per Sqm at the
junctions of masonry and concrete works to a width of 100 Sqm Qro
to 125mm including tying in position with suitable
clamps/screws,necessary staging,scafolding and curing at
all levels and elevations etc.complete as directed.

6.13 Plastering of R.C walls, peripheral beams and columns with


CM 1:3, 12 mm thick with a neat floating coat of cement for
smooth finish according to the specification. Rate shall
include for providing G.I.chicken mesh made out of
galvanised iron of nominal thickness 0.35 mm with a Zinc
coating of 120 gms per Sqm at the junctions of masonry Sqm 850
and concrete works to a width of 100 to 125mm including
tying in position with suitable clamps/screws,necessary
staging,scafolding and curing at all levels and elevations
etc.complete as directed.

C.R.Narayana Rao
Architects &Engineers 122 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.14 Providing 20 mm thick water proof plaster to tanks in C.M


1:3, finished smooth with a floating coat of neat cement
using CICO No: 1 or approved water proofing compound
Sqm Qro
by weight to the required percentage as per Manufacturers
specification and as directed.

6.15 Plastering of ceiling including slabs, beams and column


drops and staircase waist slabwith CM 1:3, 6 mm thick with
a neat floating coat of cement for smooth finish according to
the specification. The rate shall include necessary Sqm 630
scaffolding, form work and curing etc. complete all as
directed.

6.16 Plastering for external surfaces with base coat of 20 mm


thick in C.M 1:4 with water proofing compound of CICO
No.1 or equivalent as per Manufacturer's Specification and
finishing coat of 10 mm thick in C.M 1:3 after roughening
the surface of first coat in green condition with wire brush
and clearing of loose particles with sponge finish (washed Sqm 485
sand finish) all complete as per specification and as
directed. Rate shall include for providing drip bands /
moulds / grooves to any size and shape as directed.

6.17 Providing three coats of 'ACRYLIC Emulsion Paint to walls


of approved colour over a coat of water based primer
including preparation of surface by thorough cleaning and
wetting and applying POP/Gypsum powder putty as per
Sqm 850
manufacturers specification fully to give an even shade
before painting and curing as per manufacturers
specifications and as directed.

6.18 Applying white washing three coats to ceilings and walls


with pure shell lime or fat lime conforming to IS-712 all as
per Specification and as directed. For shaft , lift interior Sqm 630
walls.

6.19 Providing two coats of first quality water proof cement paint
of approved make and colour over a priming coat of white
colour water proof cement paint or any primer specified by
the manufacturer including preparation of surface by Sqm 485
thorough cleaning and wetting before painting and curing all
as per manufacturer`s specifications and as directed.

6.20 Providing flooring with best quality Kajaria / Nitco / Johnson


or approved equivalent make ceramic tiles (Anti skid/ Non
slippery) ranges as listed below shall have size of 300 x 300
mm / 400 x 400 mm - 7.0mm thick set in CM 1:4, 20 mm
thick and pointing the joints with Roff Tile filler compound
as per Manufacturer's Specification and as directed. Rate
shall include for preparation of base surface, and finished
the surface, cleaning the surface, and protecting and with
Gypsum / POP layer over Plastic sheet and removing the
same before handing over,work at all levels etc. complete
all as directed.

C.R.Narayana Rao
Architects &Engineers 123 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

I. Special printed series Sqm Qro


ii. Printed series Sqm Qro
iii. Plain series of tile size 200x200 mm. Sqm Qro
6.21 Providing dadoing with best quality Kajaria / Bell or
approved equivalent make ceramic tile ranges as listed
below shall have size of 200 x 300 x 7 mm thick set in Roff
tile adhesive component and jointing with Roff tile joint filler
grout compound, all as per manufacturer's specification, at
all levels and as directed. Rate shall include for
preparation of plastered surface, smooth joint, cleaning and
acid wash etc. complete and as directed.
I. Special printed series Sqm Qro
ii. Printed series Sqm Qro
iii. Plain series of tile size 200x200 mm. Sqm 450
6.22 Providing and laying glazed ceramic tiles (white / Coloured)
of approved make for floor tile & wall tile shall have size of
200 x 200 mm - 7.0 mm thick set in CM 1:4, 20 mm thick
and pointing the joints with Roff Tile filler compound as
per Manufacturer's Specification and as directed. Rate
shall include for preparation of base surface, and finished Sqm 390
the surface, cleaning the surface, and protecting and with
Gypsum / POP layer over Plastic sheet and removing the
same before handing over, work at all levels etc. complete.

6.23 Providing and laying in panels not more than 20 sqm. in


plan granolithic flooring with cement concrete 1:1.5:3 by
using coarse graded aggregate of 6 to 12 mm size laid
monolithic with floor concrete and finished smooth with
power trowel including preparation of concrete surface and
form work. The screed strips shall be fixed on the base
concrete with 6 mm thick solid aluminium or other metals
strips for effective separation of panels not exceeding 20
sqm. in plan etc. complete as per Specifications and as
directed. Unevenness in floor finish shall not exceed + 2mm
in one square metre area.

a 50 mm thick. Sqm Qro


b 40 mm thick. Sqm 180
c 25 mm thick. Sqm Qro

C.R.Narayana Rao
Architects &Engineers 124 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.24 Treatment on PCC levelling course below base slab,


Junctions of side walls and base slab of UG Sump etc.
covering the following sequence of operation :

a) Providing, supplying, mixing, laying cement screed


plaster 20 mm thick in cement concrete slurry 1:2:4 mixed
with 6mm & down grade course graded aggregate with
water proofing compound like CICO NO:1 (normal setting
integral water proofing compound) or approved equivalent
conforming to IS at the rate specified by the manufacturer
over PCC levelling course at any depth & height.

b) Providing, supplying, mixing, applying two coats of ready


to use two component Acrylic polymer modified cement
based, flexible, water proofing slurry like TAPECRETE or
approved equivalent to a thickness of 2 mm over the
plastered surface of operation above.

c) Providing and laying water proofing treatment with


Membrane type water proofing methods using polymer
modified Bituminous membrane of CICO shield /Build
Wrap/ Deboer make or approved equivalent make. The
Atactic Poly-Propylene (APP) membrane shall have UV
resistant property, ground chemical resistant, high melting
points, flexible and elastic with high adhesive strength. The
membrane shall be reinforced with non woven polyester
reinforcement of minimum of 180 g/sqm and reinforced with
glass fibre grill of 8 g/sqm including coating with compatible
primer of Bituminous base whereever it is required and
torch application with overlap of 70 - 100 mm wherever
required. Cost to include laying by loose and torching the
prefabricated overlap at ends. The membrane surface shall
be procted with granules.

d) Providing, supplying, mixing, laying cement concrete


screed 40 mm thick with CC slurry 1:2:4 mixed with 12mm &
down grade course graded aggregate with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth & height.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 700
plants, mixing device and gauge,Shuttering etc.complete as
per manufacturer's specification and as directed.

C.R.Narayana Rao
Architects &Engineers 125 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.25 Providing chemical injection in the form of pressure grouting


to the base slab,and side walls of UG Sump from interior
surfaces works at any depth, height and level by injecting
cement slurry mixed with grout with CICO non shrink
grouting compound or approved equivalent admixed with
cement slurry in the required consistency through the
prefixed GI nozzles in the 18mm dia holes drilled in grid
pattern at a spacing not exceeding 1 metre c/c on the top of
base slab/retaining wall & surfaces under pressure using
grout pump. Nozzle fixing and grouting for a retaining wall
shall be only at construction joints and honeycomb areas on
approval.

Rate shall include for preparation of surface, de-watering,


drilling holes, using pneumatic hammer for fixing of GI
nozzles to the required depth, grouting admixture and finally
cutting the projected nozzles and sealing of the GI nozzles
after injection operation is over with CICO NO:3 quick
setting material or approved equivalent admixed with
cement, finishing, curing, etc., as per manufacturers
specification. Rate shall include for preparation of surface
by mechanical upgrading to remove all loose mortar and
laitance, oil, grease etc. and washing the surface with water
to get neat surface, dewatering, finishing, curing,
scaffolding, waterproofing chemicals, wastage,
conveyance, tools and plants, mixing device and gauge,
shuttering, Nozzles etc. complete as per manufacturer's
specification and as directed.

Mode of measurement:

Note : Item no. a) Top of raft slab of basement lift pit base
slab and UG sump base slab ie. width and length between
the retaining wall only will be measured and paid for.

Note : Item no. b) Grouting carried out on the vertical


surfaces(Internal) of the Retaining wall of the basement, lift
pit & UG sump will be measured and paid for.

a Raft slab & lift pits Sqm 700


b Retaining walls of basement Sqm 500
6.26 Treatment to side wall of varying thickness of UG Sump
from exterior surface covering the following sequence of
operations :

a) Providing, supplying, mixing, applying two coats of ready


to use two component acrylic polymer modified cement
based flexible water proofing slurry like TAPECRETE or
approved equivalent conforming to IS to thickness of 2
mm on the surface of side wall prior to the chemical
injection treatment is completed as specified under item
above.

C.R.Narayana Rao
Architects &Engineers 126 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

b) Providing and laying water proofing treatment with


Membrane type water proofing methods using polymer
modified Bituminous membrane of CICO shield /Build
Wrap/ Deboer make or approved equivalent make. The
Atactic Poly-Propylene (APP) membrane shall have UV
resistant property, ground chemical resistant, high melting
points, flexible and elastic with high adhesive strength. The
membrane shall be reinforced with non woven polyester
reinforcement of minimum of 180 g/sqm and reinforced with
glass fibre grill of 8 g/sqm including coating with compatible
primer of Bituminous base whereever it is required and
torch application with overlap of 70 - 100 mm wherever
required. Cost to include laying by loose and torching the
prefabricated overlap at ends. The membrane surface shall
be procted with granules.

c) Providing and laying solid block 150mm thick using


cement mortar 1:3 with 75mm thick RC band @ every 1m
intervals with nominal reinforcements of 3 Nos of 8mm dia,
over the APP membrane as directed.

d) Providing, supplying, mixing, laying cement plaster 15


mm thick with cement mortar 1:4 mixed with approved water
proofing compound like CICO NO:1 or equivalent
conforming to IS at the rate specified by the manufacturer
over the coated surface of operation specified in point no.
(a) above.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 500
plants, mixing device and gauge, shuttering, Nozzles etc.
complete as per manufacturer's specification and as
directed.

6.27 Treatment on junctions of base slab & wall and side walls
in UG Sump internal surfaces etc. covering the following
sequence of operation:

a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)
b) Providing, supplying, mixing, applying two coats of ready
to use two component Acrylic polymer modified cement
based, flexible, water proofing slurry like TAPECRETE or
approved equivalent to a thickness of 2 mm over the
plastered surface of operation above.

C.R.Narayana Rao
Architects &Engineers 127 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

c) Providing, supplying, mixing, laying cement plaster 15


mm thick with cement mortar 1:4 mixed with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth below finished floor level.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 500
plants, mixing device and gauge, shuttering, etc. complete
as per manufacturer's specification and as directed.

6.28 a Water proofing treatment Treatment over RCC roof slab laid
to slope in terrace and gutter slab covering the following
sequence of operation and specifications:
a) The roof slab laid in slope / gutter slab shall be
thoroughly cleaned by removing the debris and dust, to
receive the water proofing treatment.

a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)

c) Applying 2 coats of acrylic polymer modified cement


based, flexible water proofing slurry like TAPECRETE or
approved equivalent make to a thickness of 2mm and cured
for 7 days and as per manufacturer's specification.

d) Supplying, providing and applying water proofing


treatment with Membrane type water proofing methods
using polymer modified Bituminous membrane of CICO
shield/ Build Wrap/ Deboer or approved equivalent make.
The Atactic Poly-Propylene (APP-4mm th)membrane
having UV resistant, ground chemical resistant, high melting
point more than 110 deg. C, flexible and elastic with high
adhesive strength. The membrane shall be reinforced with
non woven polyester reinforcement of minimum of 180
g/sqm and reinforced including coating with compatible
primer of Bituminous base and torch application with
overlap of 100 mm wherever required. The reinforcement
provided shall be able to withstand the traffic flow density
during & after construction and shall carry a minimum
guarantee period of 10 years. Cost to include applying the
primer and torching the entire surface and also
prefabricated overlap at ends. The membrane surface shall
be protected with granules.

C.R.Narayana Rao
Architects &Engineers 128 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

e) Providing, supplying & laying extruded polystyrene rigid


foam panel of size600 x 1200mm-75mm thick of formula
R.Metric-FM 50 having a density of 24 kg/cum and
compressive strength not less than 250 kpa of ownes
corning or approved equivalent make having exeptional
mechanical properties like resistance to the diffusion of
water vapour, resistance to water absorption, uniform
density distribution, dimensional stability, very high
compressive strength, aging resistance and also immunity
against insects, pets, bacteria, rodent attacks and micro
organisms etc., for over deck insulation including necessary
skin shiplap joint,anchores,adhesives, primers etc., as
required for proper fixing etc., complete all as per the
manufacturers specifications & consultants approval. The
extruded polystyrene panel has closed sealed cells
structure linked to one another is produced by a contineous,
fully automated extrusion process in accordance with
international specification and standard etc. all complete.

f) Laying fibre glass cloth over the extruded polystyrene


rigid foam panel.

g) A layer of 20 mm thick cement mortar 1:4 admixed with


CICO NO - 1 (normal setting integral water proofing
compound) or other approved equivalent make compound
shall be spread over the operation specified in point (f)
above and laying brickbat coba over the surface 40mm
thickness at drain point and required thickness at ridge and
the top surface of the brickbat coba shall be plastered with
cement mortar 1:4, 20 mm thick admixed with CICO NO:1
@ 2% by the weight of cement and add RECRON 3S 225
per bag of cement and draw false line of 300 mm X 300 mm
over the finished surface. (The rate shall be quoted for an
average thickness of 110 mm).

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface,dewatering, finishing, curing, scaffolding, supply
and adding water proofing chemicals at the specified
proportion as per manufacturer's specifications, all
materials, wastages, conveyance, tools and plants, mixing Sqm 620
device and gauge, shuttering and also include for
conducting leakage test at terrace by storing water on the
terrace for about 25 mm depth continuously for a period of 7
days etc.complete, as directed.

b Extra rate over and above item no (g) above, for Providing
and laying brickbat coba. Cum Qro

C.R.Narayana Rao
Architects &Engineers 129 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.29 Providing & fixing of MS handrail 1000mm clear height of


size 32mm dia as verticals at 900mm c/c firmly fixed to the
R.C. steps welded with 75x75x6mm ms insert plate with
necessary lugs and providing of 2Nos. of 32mm dia ms
pipes as horizontals at equal distance should be welded Rmt 125
with verticals by 25 dia ms pipe including necessary tools
and plants required etc. complete including one coat of
primer and two coats of paint.

6.30 Providing and fixing in position Fixopan or approved


equivalent make PVC water stopper of type 240-H as per
manufacturers specification and laid horizontally in
construction joints centrally in the raft slab and vertically
Rmt 50
along the centre at junction of raft slab and outer vertical
walls of basement floor and UG sump floor slab / RC side
wall, all complete and as directed.

6.31 Providing and fixing in position Fixopan or approved


equivalent make PVC water stopper of type 230 KE with
suitable cap at expansion joint externally placed in RCC
Rmt 50
elements along soffit of raft beam and all as per
manufacturers specification, all complete, as directed.

6.32 Supplying and fixing G.I.Puddle Flanges of various dia and


size made out of G.I with screwed ends, cap and plates for
embedment in concrete as necessary with suitable
accessories, consumables welding accessories including
placing in position, grouting, making necessary provision in
the centering & shuttering etc, including one coat of zinc
rich primer complete and as directed.

A 50mm to 80mm dia


I Between 300 & 600 mm long Each 6
ii. Between 601 & 1200 mm long Each 6
B 100mm to 150 dia
I Between 300 & 600 mm long Each 2
ii. Between 601 & 1200 mm long Each 2
C 200 mm to 250mm dia
I Between 300 & 750 mm long Each 2
ii. Between 751 & 1500 mm long Each 2
D 300mm to 350mm dia
I Between 300 & 750 mm long Each Qro
ii. Between 751 & 1500 mm long Each Qro
6.33 Supplying and fixing poly-propelene rungs of 20 mm square
bar of size 263 x 165 mm for access way including
anchorage in walls to a minimum depth of 100 mm with C.C Each 75
1:2:4 etc. complete and as directed.

C.R.Narayana Rao
Architects &Engineers 130 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.34 Supplying and fixing Heavy duty CI manhole cover and


frame of " NECO" make,cover weighing not lesser than the
following and being a size of 600 x 600 mm for overhead
tank including painting with two coats of anticorrosive paint
over a coat of primer etc. Rate shall include providing and
fixing locking arrangements, fixing the Man-hole cover,
grouting the anchors with C.C 1:2:4 as per specification
and as directed.
Weight Not less than 50 Kg. Each 6
6.35 Providing and fixing GI vent pipe 100 mm dia. and 2 M long
above the underground sump cover slab as shown in the
drawing including fixing with necessary supports like
clamps, bolts etc. as per specification and as directed
Nos 5
including painting two coats of first quality synthetic enamel
paint of approved make and tint over one coat of primer all
as per specification and as directed.

6.36 Providing and fixing PVC (6 Kg/sqcm


class)Finolex/Supreme or equivalent pipe of specified dia
below and approved make as water down take pipe with all
specials, accessories and joints with solvent cement
solution according to manufacturers specification.

a 150 mm dia. Rmt 25


b 110 mm dia Rmt Qro
c 200 mm dia. Rmt 25
d 300 mm dia. Rmt Qro

Total C/o.to Summary of 3 C in Rs..

C.R.Narayana Rao
Architects &Engineers 131 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

SECTION 3 D - SUB-STAION BUILDINGS, SECURITY &


DRIVER'S REST ROOM

1.00 SUB-STATION WORKS

1.00 EARTH WORK EXCAVATION


GENERAL NOTES FOR EXCAVATION
Contractor shall take all required permissions from the
appropriate authorities for Excavation, Blasting, Carting
away materials including depositing, levelling etc. and shall
bear all the expenses for the same.

Rate includes removal of all kind of vegetation,small shrubs


etc. Dewatering water to be let out of the building / site area
through proper pipes & channels if required. The contractor
at his own expenses shall water very well, ram and
thoroughly consolidate the bottom of all excavations &
ground before the construction of foundation/footing/plinth
beam, filling in basement floor or other work is
commenced.The rate for excavation shall include for
shoring sides or trenches with approved timber/steel
accessories wherever necessary to prevent sides from
falling including bailing or pumping out of water if necessary
and include If there are any shrubs, bushes, trees, roots of
the trees to be removed for min depth 50. Necessary Lift &
lead for all type of excavated materials to convey them and
to deposit them as directed by the engineer-in-charge are to
be considered.

Contour level to be taken jointly with the engineer-in-charge


and prior written approval to be taken before starting any
excavation/ filling at every 3 / 5 mt grids or at regular
intravels as directed by the engineer -in-charge for arriving
at the actual quantity. Measurements for filling will be taken
for consolidated thickness only.Cost to include all and
necessary royalty and other permission charges required to
execute the works.Unless noted otherwise measurements
shall be considered to the edge of PCC only.

Note: The measurements shall be based on the levels


captured prior and after execution. And in case of stack
measurement, the percentage of 40 % of voids to be
deducted from stack measurement for hard rock (Incase
operated). Blasting shall be carried through licensed
operator having valid blasting licence.

C.R.Narayana Rao
Architects &Engineers 132 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

1.01 General Excavation by mechanical means in all types of soil


including dense soil, discentegrated/ weathered/ soft rock
for any type of foundation including necessary manual
excavation for dressing the edges & leveling, all leads and
lifts back filling in layers of 150mm with watering and
compaction to the required proctor density . Rate to include
disposing the excess earth and spreading in layers to the
required levels within the site wherever
specified,dewatering of both ground and surface water,
removal of slurry generated while excavation and keeping Cum 500
the area free of water with necessary shoring, struting,
required for keeping earth in position etc,. excavating loose
pockets and compacting the same. Note: Aut
working space and Provision of slopes if required for
execution shall not be paid separately.
Excavation in all types of soils to any depth below ground
level.

1.02 Excavation in Medium rock ( more than 1/2 Cum in size -Un-
poclainable) to the required level & depth (Mass
excavation) including all leads and lifts, stacking excavated
material within plot at approved location , if required de-
watering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
of water with necessary shoring, strutting, stepping, Cum 250
dressing, grading required for keeping earth in position etc.
as per detailed specificationand conforming to safety rules
during progress of the work. Note:Authorised working
space and Provision of slopes if required for execution
shall not be paid separately.

1.03 Same as item No - 1.01 but for general excavation in Hard


rock/ boulders (more than 1/2 Cum in size -Un-poclainable)
by chiselling/ wedging to the required level & depth (Mass
excavation) including all leads and lifts, stacking excavated
material within plot at approved location , if required de-
watering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
of water with necessary shoring, strutting, stepping, Cum 375
dressing, grading required for keeping earth in position etc.
as per detailed specificationand conforming to safety rules
during progress of the work. Note:Authorised working
space and Provision of slopes if required for execution
shall not be paid separately.

C.R.Narayana Rao
Architects &Engineers 133 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

1.04 Excavation in hard rock / boulders (more than 1/2Cum in


size) by Controlled Blasting using explosives and trimming
to required level for foundation, trenches, rafts, plinths,
leveling area etc. to the required depth at all leads including
stacking excavated material within plot at approved
location, if required bailing /pumping out of water to keep
site dry at all times until completion of work; shoring, Cum 375
strutting, stepping, dressing, grading, cleaning, removing
and excavating loose pockets as directed etc. all complete
as detailed in specification and conforming to safety rules of
authority from time to time and Explosives rules1940 or as
amended.

1.05 Carting away surplus earth/excavated material/debris and


like materials outside the plot not covered under above
items 1.01 to 1.04 all above items and disposing off the
same to the designated areas identified by the local Cum 1500
authorities/engineer-in-charge for dumping of such
material,including spreading,compacting etc.,as per the
norms by the local authorities.
1.06 Supply and filling in foundations and the area wherever
specified with approved good quality filling materials in
plinths, sides of retaining wall alround the building ( i.e
backfilling ) area development etc. wherever specified in
layers of not exceeding 150 mm thick including breaking
clods,storing,transportation ,double handling, watering,
compacting each layer with vibratory compactor and at
unaccessible places with wooden/steel rammers to achieve
90 to 95% proctor density at optimum moisture content, all
leads and lifts, bailing/ pumping out of water to keep site dry
while backfilling; cost shall include conveyance of all
materials, labour, machinery etc. complete as directed.The
rate to include loading,unloading, hire and fuel charges for
tools and plants and other incidental charges etc., complete
as directed.

a With approved quality murrum brought from outside. Cum 5


b Approved quality river sand brought from outside Cum 5
c With approved quality quarrydust brought from outside Cum 5
1.07 Providing and laying in position 150mm thick soling with
approved Base preparation by Mechanical compaction,
using hard granite stones / Rubble and smaller pebbles for
void filling, moorum for binding as directed by the Engineer- Sqm 25
in-charge including watering,packing, compaction etc., with
required tools and plants and all lead,lift, conveyance as
required etc., complete as directed.

C.R.Narayana Rao
Architects &Engineers 134 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

1.08 ANTI-TERMITE TREATMENT WORKS


Providing Anti termite treatment in accordance with
stipulations laid down by IS 6313 - part II by approved
agency with min of 10 years of guarantee including the cost
of chemical,precautionary measures etc.complete along
retaining walls only for a width of one meter or as specified
by consultants (treatment for floor is not required and Sqm 135
agency shall be approved by engineer-in-charge
Note: External periphery length of the retaining wall
multiplied by 1 M will be considered as the measurement
area.

2.00 PLAIN & REINFORCED CEMENT CONCRETE WORKS


2.01 Providing and laying plain cement concrete 1:4:8 using
coarse graded aggregate of 40 mm and down size for
levelling course under footings, steps, walls, platform etc. Cum 25
including form work wherever necessary and well
compacted etc. all complete, as directed.

2.02 Providing and laying P.C.C. 1:3:6 of specified thick


wherever specified using river sand, 20mm and downsize
metal including base reperation, Compaction, levelling, all Cum 1750
leads and lifts, curing and shuttering if necessary etc.,
Complete
2.03 Providing and laying P.C.C. 1:2:4 of specified thickness
wherever specified using river sand, 20mm and downsize
aggregate including cleaning,subgrade preparation,
Compaction, levelling, all leads and lifts, rough finishing at
the top surface,curing and shuttering if necessary etc.,at all
heights and depths as instructed.

a DPC, Copings, Flagging concrete, shaft screed etc., Cum 25

READY MIX CONCRETE / CONTROLLED CONCRETE


NOTE: RMC SHALL BE PROCURED FROM SITE
BATCHING PLANT HOWEVER, IN CASE OF READY MIX
CONCRETE PROCURED FROM RMC PLANT THE
PROBABLE CONCRETE CAN BE FETCHED FROM (L&T/
IJM / Redimix).
Providing, batching, mixing, transporting through transit
mixers, pumping and laying controlled Reinforced Cement
Concrete of specified grade at all levels and heights
specified below using ordinary Portland cement of grade 53
from approved manufacturer, river sand, 20mm and down
size coarse aggregates, necessary Mineral admixtures
approved by Consultants (elkem and Conplast SP 430SRV
from Fosroc or equivalent), including all leads and lifts,
pumping using line pump or boom placer, vibrating/
compaction, scaffolding wherever necessary, curing as
directed, excluding cost of shuttering and reinforcement
works.

(Design mix shall be as approved by the Structural


Consultant / Employer's representatives

C.R.Narayana Rao
Architects &Engineers 135 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.04 Columns at

M35 Grade

Basement-1 Cum 75

Ground floor Cum 86

First Floor Cum 100

M30 Grade

Terrace Floor Cum 25

2.05 Flat Slabs (including Conventional slab)

M30 GRADE

Ground floor Cum 500

First Floor Cum 300

Slab for cable duct Cum 150

Terrace Floor Cum 450

Above Terrace Cum 25

2.06 Beams at all levels

M30 GRADE

Ground floor Cum 125

First Floor Cum 125

Terrace Floor Cum 160

Above Terrace Cum 25

M30 GRADE CONCRETE

2.07 RCC Parapet at all levels of specified thickness Cum 50

Footings/ Rafts for columns,Core walls/ Retaining walls


2.08 Cum 390
etc.,

2.09 Grade slab Cum 450

2.10 Retaining wall Cum 135

2.11 Staircase including the Landings

Basement 1 Cum 10
Ground floor Cum 10
First Floor Cum 10
2.12 Lintels at all levels
Basement 1 Cum 2
Ground floor Cum 4
First Floor Cum 4
Terrace Floor Cum 2

C.R.Narayana Rao
Architects &Engineers 136 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.13 RCC Brackets/Fins/Ledges/lofts at all levels Cum 5

2.14 Pedestals , foundations for Equipments Cum 320

2.15 Mullion columns at all levels Cum Qro

Supplying, drilling and fixing MS anchor rod of 16 mm dia


into the hard rock for 200 mm below footing and 200 mm
2.16 Nos Qro
anchoring into the footing.Rate shall include for material for
Cement grouting and labour etc, complete

2.17 M25 Grade Concrete


a. RCC Parapet at all levels of specified thickness Cum Qro
b Lintels at all levels Cum Qro
c RCC Brackets/Fins/Ledges at all levels Cum Qro
d Cill concrete/Fins /Chejjas/Lofts at all levels Cum Qro

2.18 M20 Grade Concrete


a. RCC Parapet at all levels of specified thickness Cum Qro
b Lintels at all levels Cum Qro
c RCC Brackets/Fins/Ledges at all levels Cum Qro
d Cill concrete/Fins /Chejjas/Lofts at all levels Cum Qro

Reduction in rates for usage of PPC in place of OPC for


2.19 various grades of concrete for various elements listed
above.
a. M20 Cum Qro
b M25 Cum Qro
c M30 Cum Qro
d M35 Cum Qro
e M40 Cum Qro
f M45 Cum Qro

C.R.Narayana Rao
Architects &Engineers 137 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.00 FORM WORK


3.01 Providing, fabricating and erecting form work at all levels
and places wherever needed/specified as per drawing
including striking with 12mm Plastic coated, marine
resistant waterproof ply/Smooth finished MS plates with
adjustable steel props of acceptable Staging system and
with sufficient bracing as approved by consultant. Cost to
include designing of proper form work and staging system
to suit the requirements,Submission of design calculations
and shop drawings for approval,sealing the joints with
heavy duty brown self adhesive tape, aligning to line and
levels including M.S. Ties, PVC Spacer, Providing
openings/ cutouts/ pockets, applying deshuttering chemical,
Deshuttering as approved by the consultant etc., complete
at all levels, double/tripple heights and profiles for Note :
Only plan area shall be considered.No extra shall be paid
for Side shuttering of Drop panel/column capitals.

1) plywood shuttering shall be considered for all vertical


elements, beam soffit, corewalls, stairs, ramps, tanks,
RCCpedestals Etc.,
2) M.S. plates shall be considered for foundation,slabs
only.
3) Shuttering & deshuttering sequence shall be 100%, 80%
& 40% from the slab to be cast respectively

a Columns at

Basement 1 Sqm 750

Ground floor Sqm 860

First Floor Sqm 1000

Terrace Floor Sqm 250

b Flat Slabs (including Conventional slab)/

Ground floor Sqm 1620

First Floor Sqm 970

Slab for cable duct Sqm 498

Terrace Floor Sqm 1440

Above Terrace Sqm 48

c Beams

Ground floor Sqm 1375

First Floor Sqm 1375

Terrace Floor Sqm 1775

Above Terrace Sqm 300

3.02 RCC Parapet at all levels of specified thickness Sqm 500

C.R.Narayana Rao
Architects &Engineers 138 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Footings/ Rafts for columns,Core walls/ Retaining walls


3.03 Sqm 450
etc.,

3.04 Grade slab Sqm 135

3.05 Retaining wall Sqm 1350

3.06 Staircase including the Landings

Basement 1 Sqm 70

Ground floor Sqm 70

First Floor Sqm 70

3.07 Lintels at all levels

Basement 1 Sqm 25

Ground floor Sqm 45

First Floor Sqm 45

Terrace Floor Sqm 25

3.08 RCC Brackets/Fins/Ledges at all levels Sqm 50

3.09 Pedestals , foundations for Equipments Sqm 750

3.10 Mullion columns at all levels Sqm Qro


3.11 Providing, fixing reinforced cement concrete precast slab
with controlled cement concrete - M20 grade using coarse
graded aggregate 12 mm and downsize for shelf etc. Rate
shall include for providing necessary casting platform,
shuttering, reinforcement as detailed below, finishing
exposed faces smooth wherever necessary and pointing
the joints with C.M 1:3, 15 mm thick curing and fixing in
position etc complete and as directed. Rate shall include for
providing necessary MS angles of required size based on
the thickness of precast slab and to be fixed on the edges
of the precast slab including grouting the lugs with Cement
concrete 1:1.5:3, GI Hooks for lifting the slab etc complete,
as directed.

a 100 mm thick Sqm 15


b 50 mm thick Sqm 15
3.12 Providing and fixing precast reinforced cement concrete jalli
work, with controlled cement concrete - M - 20 grade using
coarse graded aggregate of 6 mm and downsize as per
drawing including fixing in position with cement mortar 1:3.
Rate shall include for cost of form work wherever required
and cost of nominal reinforcement with 8mm dia.-Fe 415
steel at required spacing confirming to IS standards and
specification etc complete and as directed.

a. 100 mm thick Sqm 5

C.R.Narayana Rao
Architects &Engineers 139 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.00 IRON & STEEL WORKS

4.01 Providing and fixing reinforcement for RCC work with high
yield strength ribbed cold twisted tor steel (HSD) bar of
various diameters and grade of steel as specified below
conforming to IS or equivalent BS specification including
cutting and waste, bending, hoisting, fabricating and placing
in position according to drawings and binding the
reinforcement with galvanised annealed binding wire of
double fold of 18 gauge and providing PVC cover blocks
for placing the reinforcements in position and for
maintaining the cover specified and/or according to
relevant IS or equivalent BS code.

Note : Unless noted otherwise the measurements in


accordance with IS 1200 or equivalent BS. However
reinforcement shall be measured only in lengths of bars as
actually placed in position on standard weight basis, no
allowance being made in the weight for rolling margin.
Authorised laps and splices, Chairs of any shape & profile,
Spacer bar of any shape & profile, cover block, wastage
and binding wire will not be measured and shall be included
in the quoted rates.Quoted rate shall be deemed to have
considered the above stipulation.Quoted rate to include
lead, lift, placing at all levels and as directed. Detailing of
the reinforcement shall be ductile detailing for seismic
zone III as per codal requirement

I Grade of reinforced steel - Fe 500 MT 400


4.02 Providing and fixing in position Hot rolled structural steel
Members / Sections at all levels and to any shape & profile
consisting of MS joists, channels, angles, purlins, runners,
insert plates, flats and sag rods with necessary sleeves,
bolts and nuts, gratings, pipes including cutting,
straightening, welding as per standards for connections MT 75
including consumables etc.complete. Rate shall include
preparation of surface, applying two coats of Zinc
chromate/Phosphate primer before and after erection etc.
complete, as directed.

4.03 Providing, Fabricating and erecting in position structural


steel conforming to IS 800 as corner angles(50x50x6MM)
for columns, Edge angle for Catch pits and wherever
specified as per drawings. Cost to include necesary MS
flats for anchorages,hold fasts,anchor bolts,applying one MT 5
coat of Zinc chromate/Phosphate primer and two coats of
first quality synthetic enamel paint of approved make etc
complete,as directed.

C.R.Narayana Rao
Architects &Engineers 140 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.04 Providing and fixing in position M.S.chequered plate 5mm


thick with necessary supports such as M.S. angles/M.S.
flats including stiffeners to be placed on angle iron frame
work. (Frame work, angles, stiffners will be measured under
relavent structural steel item). Rate shall include making
MT 5
necessary cutouts for inserts, applying one coat of Zinc
chromate/Phosphate primer and two coats of first quality
synthetic enamel paint of approved make etc complete,as
directed.

Total C/o.to Summary of 3 D in Rs..

5.00 MASONRY WORKS


5.01 Providing and constructing brick work with best quality
well chamber table moulded bricks with minimum
compressive strength of 50 Kg per Sqcm in cement mortar Cum 50
1:5 in foundation and basements, etc. complete, all as
directed.

5.02 Providing and constructing brick work with best quality well
chamber table moulded bricks with minimum compressive
strength of 50 Kg per Sqcm. in cement mortar 1:5 in Cum 50
superstructure at all levels etc. complete, all as directed.

5.03 Providing and constructing 115 mm thick masonry wall at all


levels with approved best quality well chamber burnt
moulded bricks with minimum compressive strength of 50
Kg/Sq.cm in cement mortar 1:4 with M20 reinforced cement
concrete binders - 80 mm thick laid horizontally to the full
length of the wall at 1000 mm ctc using coarse graded
aggregate of 12 mm and downsize and reinforced with 8
mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm dia for Sqm 50
stirrups at 200mm centres using Fe 500 grade steel. Rate
shall include for cost of reinforcements and tying in postion
using binding wire made out of 16 gauge GI annealed or 18
gauge SS, form work, scaffolding, raking out joints, curing
etc complete and as directed.

5.04 Providing and constructing cement concrete solid block


masonry work at all levels in cement mortar 1:3 using
standard size of 400 x 200 mm of solid cement concrete
blocks of thickness as specified below having compressive
strength of 5.5 N/ sqmm including all scaffolding, staging,
curing, all lifts etc. complete and as directed as per the IS
relevant standards. Concrete blocks manufactured under
strict quality control conditions using modern rugged block
casting and stripping machine with the latest moulding
techniques etc. only shall be used.

a. 200 mm thick wall Sqm 7500

b. 150 mm thick wall Sqm 50

C.R.Narayana Rao
Architects &Engineers 141 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

c. 100 mm thick wall Sqm 50


5.05 Extra rate over & above Solid / Hollow Masonry wall for
providing R.C.Binders of 80 mm thick laid horizontally to
the full length of the wall at 1000 mm ctc using coarse
graded aggregate of 12 mm and downsize and reinforced
with 8 mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm
dia for stirrups at 200mm centres using Fe-500 grade steel,
including cost of reinforcements and tying in postion using
binding wire made out of 16 gauge GI annealed or 18
gauge SS, form work, scaffolding, all labour, hire and fuel
charges for all tools and plants employed and all other
incidental charges etc. all complete, as directed. ( For both
internal and extrernal walls )

a. Solid block wall of 200 mm thick Sqm 7500

b. Solid block wall of 100 mm thick Sqm 50

6.00 FLOORING AND DADOING WORKS


6.01 Providing and laying in panels not more than 20 sqm. in
plan granolithic flooring with cement concrete 1:1.5:3 by
using coarse graded aggregate of 6 to 12 mm size laid
monolithic with floor concrete and finished smooth with
power trowel including preparation of concrete surface and
form work. The screed strips shall be fixed on the base
concrete with 6mm thick solid aluminium or other metals
strips for effective separation of panels not exceeding 20
sqm. in plan etc. complete as per Specifications and as
directed. Uneveness in floor finish shall not exceed +2mm
in one square metre area.

I. 50 mm thick.
Sqm 4658

ii) 25 mm thick.
Sqm Qro

6.02 Extra over for providing and mixing READY MIX DRY
SHAKE ABRASION RESISTANT FLOOR HARDENER of
non - metallic monolithic surface floor hardening compound
CICO FLORTOP-E RTU from CICO or TecTM Floor Z from
TECHNY CHEMY make over the laid concrete at the rate of sqm 4658
minimum 5.0kg/m2 using power trowelling for quick and
making smooth levelled surface etc.,all as per
manufacturers' specifications.

C.R.Narayana Rao
Architects &Engineers 142 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.03 Providing flooring with best quality approved Kotah stone


slab not less than 20 mm thick and the size of slab in
general not less than 600x600 mm, machine cut and
machine high pre-polished, set in C.M 1:4, 20 mm thick
topped with white cement slurry (for surface contact of the
bottom of the granite slab) as per approved pattern/design
by using irrespective of size and shape, including finishing
the joints with white cement slurry, cutting, edge chamfering
Sqm Qro
and polishing rough, medium, nice and acid wash and tin-
oxide polish as per manufacturer's Specification and as
directed.Rate shall include for preparation of base surface
& finished the surface, protection with gypsum/pop layer
over plastic sheet and removing the same before handing
over,work at all levels, as directed. (For Staircase Landing
Areas)

6.04 Providing and fixing step treads with approved Kotah stone
slab of thickness not less than 20 mm in single piece for
each step rounded or patterned as per drawing over a bed
of C.M 1:4, 20 mm thick, all edges machine cut, machine
polished including cutting, chamfering and making groove
to the specified size in the edges( Staircase steps),edge
polishing to rough, medium, nice, acid wash and tin oxide
polishing as per manufacturers specification and as Sqm 18
directed. Rate shall include for preparation of base surface,
jointing with matching cement slurry and finished surface
protection with gypsum / POP layer over plastic sheet and
removing the same before handing over, work at all levels
etc complete, all as directed.

6.05 Supplying and fixing of machine cut and pre-polished


Jaisalmeer for risers of stair case (
Fixing of kota stone involves topping over a bed mortar of
20 mm thick in CM 1:4 as per approved pattern including Rmt 57
finishing the joints with with cement slurry, cutting, edge
chamfering and nosing etc.)

6.06 Providing 125 mm high skirting with good quality Kotah


stone slab of thickness not less than 20 mm, with edges
machine cut and exposed faces polished to match the floor
set in cement mortar 1:3 of 12mm thick including chasing of
wall wherever necessary and making good at the junction
Rmt Qro
with necessary plastering etc. Rate shall include for rough,
medium, nice, acid wash and tin oxide polishing as per
Manufacturers specification and as directed.

6.07 Providing flooring with best quality Kajaria / Bell make


ceramic tiles ranges as listed below shall have size of 300 x
300 mm 7.0mm thick set in CM 1:4, 20 mm thick and
pointing the joints with Roff Tile filler compound as per
Manufacturer's Specification and as directed.

C.R.Narayana Rao
Architects &Engineers 143 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Rate shall include for preparation of base surface, and


finished the surface, cleaning the surface, and protecting
and with Gypsum / POP layer over Plastic sheet etc.
complete all as directed.

I. Group V / V + / IV series
Sqm Qro

ii. Special Printed series


Sqm Qro

iii. Plain series


Sqm Qro

6.08 Providing and laying , M20 grade ready mixed concrete for
non slippery, Vaccum dewatered flooring including
cleaning, trimming, watering the surface, laying in strips to
required levels, trovelling, smoothening curing etc., Cum 175
complete to the required slope, formation, finish. (VD
operation shall be paid separately)

6.09 Providing vacuum de-watered flooring operation consisting


of providing side shuttering with MS channels, angles to the
required levels, Vibrating the concrete by using screed
vibrator, de-watering using vacuum pumps by suction
method and finishing the top surface to required level and Sqm 1750
grade using skim floaters/discs/power trowels. Covering
the finished concrete surface with 200 micron thick
polythene sheet and curing etc., complete.

6.10 Extra over for providing and mixing Graded fibrillated 100%
virgin poly propelene fibres in concrete at the rate of 0.90
kg/cum as per manufacturers specifications. Fibremesh MD
Supplied by M/s Millenium buiding systems or equivalent.

a Fibremesh MD Cum Qro


b Recron 3S by Reliance Cum 175
c Cemfil HD Cum Qro

7.00 JOINERY WORKS


7.01 Providing and fixing 32mm thick flush door shutters (Kutty /
Diamond/Jackson's make) single leaf / Double leaf of solid
core of block board type bonded with phenol formaldehyde
synthetic resin thermo pressed with 8 mm thick teak wood
tongue & groove external lipping. The construction
procedure of the shutter should be as per IS 2202. The
shutter shall be shop prepared for taking mortice lock or
latches suitable lock block of wood may be provided for
fixing the hardware. The size of block, shall perfectly
correspond to the maximum size of lock, covered in IS
2209. All the four edges of the door shutter shall be
square. The shutter shall be free from twist or warp in its
plane and of required size etc. complete as directed.

C.R.Narayana Rao
Architects &Engineers 144 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

i) Hardwares :
i) Hinge : Providing and fixing Stainless steel satin finish
double ball bearing butt hinges with SS screws of size 100
x 75 x 3 mm thick - Model No. SS 551 B - class 8 / 9 from
Dorma or approved equivalent make suitably for Single /
Double leaf door. Stainless steel conforming to SS 316 L
grade to BS 7352 or BS EN 1935-2002. 4 Nos for Single
Leaf Shutter and 8 Nos for Double Leaf Shutter.

ii) Provision :
i) Provision / fixing arrangements to be made in the shutter
as well as in the frame to receive / fix the Hinges, Locks,
Electro magnetic latch, Electro magnetic contact for hooter
with reinforcement pads and in such a way to connect the
same to the card access control system / IBMS.
ii) Refer hardware schedule enclosed for the details of
Mortise sash lock, Mortise dead lock, Handles, Push plates
and Panic bar etc. Necessary provision shall be made in
the frame and shutter to receive and fix the hardwares.
iii) Supplying Master key for the doors either floor wise or
wing wise as per the Master key plan including supplying
Grand Master key for all the doors.

Note :
1. All the Materials and hardware specifications proposed
for door shall conform to the codes, technical specification
and preamble to the bills of quantities.
2. Quoted rate shall be deemed to have considered all the
items covered in the specification and drawings, whether
explicitly stated or not.

Rate shall include for making provision to fix the approved


hardwares as specified in the tender drawing schedule as a
separate item etc. complete and as directed.
Rate shall include the following

Rate shall include necessary all approved hardwares as


specified in the tender drawings etc. complete and as
directed.

a. Single leaf Flush door. Fully flush shutter with commercial


ply on both sides and finished with 1.5mm thick laminate on
both sides of approved colour, make and shade. Sqm 6

C.R.Narayana Rao
Architects &Engineers 145 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

7.02 FLUSH DOOR HARDWARES

Extra rate over and above steel door items for providing and
fixing the following Hardwares in position in the doors
supplied with all necessary accessories etc complete and
as directed.

a Mortice Sash lock with lever handle and internal thump


turn - Stainless steel satin finish - 316 L grade of ST 8100 -
lever handle on both sides with ST 7122 WC indicator with
775 lock or approved euivalent make with forend and strike
Each 2
plate of Dorma make and the strike plate shall be provided
to suit the type of door specified. Stainless steel shall
conform to BS.

b Automatic door closer Model No.TS 92 cam action G


(Push/Pullside) or B (Push/Pull side) EN 2 to 4 of Dorma
make. (Door closer shall be provided to suit the type of door
opening / opening policy specified. Ie. Double / Single leaf Each 2
and Push / pull side) with all other accessories.(To use
Shutter width upto 1100 mm)

c. Extra rate over and above item no a & b for making opening
in Toilet door in all blocks / floors for fixing the Air Transfer
grill

a. 500 x 300 mm Each 2


b. 300 x 200 mm Each 2
7.03 Providing and fixing in position frames of any size and
section for Doors, Windows, Ventilators, any openings and
in Jambs, shaped, planed and fixed with necessary jointing
method approved including pins, nails, screws and bolts
etc. Rate shall include for cost of bolts, nuts, screws,
nails, pins, Hot dip galvanised MS approved hold fast and
concrete block grouting for fixing hold fast, anchor fasteners
/ coach screws and including a coat of suitable primer on
the frames to receive the Duco paint finish / Fire Retardant
paint with suitable primer of approved colour etc. complete,
as directed.

a. First class Teakwood confirming to IS specifications and


should be free from any defects and plemishes. Cum Qro

b. First class Padauk wood conforming to IS specifications


and should be free from any defects and plemishes. Cum 0.15

7.04 Providing and fixing of hollow metal fire rated steel door 2
Hour / 1 Hour rating confirming to IS 3614 or Equivalent BS
and General purpose steel door at all levels with frames
and with fully flush type shutter having 48 mm thick made
out of Pressed Galvanised steel sheet confirming to IS 277,
(Coating shall be GLP grade Z 120 microns coating) to any
type, Size, Shape with various opening policy and of
System Schroders or approved equivalent make, but in
general the door consists of the following and the quoted
rate shall include the following :

C.R.Narayana Rao
Architects &Engineers 146 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

a) Door Frame : Fabricated from galvanized steel sheet to


the profile and the thickness specified below :
i) Fire Door - 2 Hr rating : Double rebate profile of size 143
x 57 mm (+/- 0.3) with bending radius of 1.6 mm, using
galvanized steel sheet of 1.6 mm thick (16 Gauge).
ii) Fire Door - 1 Hr rating: Single rebate profile of size 100
x 57 mm (+/- 0.3) with bending radius of 1.4 mm, using
galvanized steel sheet of 1.20 mm thick (18 Gauge).
iii) General Purpose Door : Single rebate profile of size
100 x 57 mm (+/- 0.3) with bending radius of 1.4 mm, using
galvanized steel sheet of 1.20 mm thick (18 Gauge).

Frames shall be provided with the following :


i) Back plates - 3 mm thick on all jambs with provision for
anchor bolt fixing to wall openings.
ii) Hinge plates 3 mm thick pre-drilled to receive approved
type and make of hinges for screw mounted fixing.
iii) Factory finish-pre-punched cut outs to receive specified
type & make of hardware and iron mongery. All cut outs
including hinge plates, strike plates to have mortar guard
covers from inside to prevent cement, dust ingress into cut
outs at the time of grouting of the frame.
iv) Reinforcement pads for fixing of door closer, locks and
handles at appropriate location as per manufacturers
details.
v) Plug-in type rubber silencer not less than 2 mm dia shall
be provided on the strike jambs for single shutter frames
and on the head jambs for double shutter frames.
vi) Frames shall be in knock down form with butt joints for
bolted assembly at site or as per manufacturers
specification with out visible joints/welding marks in frames.

b) Door Shutter : Shutters should be press formed with


double skins to a total 48 mm thick hollow shutter with lock
seam joints at stile edges using galvanized steel sheet of
thickness specified below :
i) Fire Door - 2 Hour rating : 1.00 mm thick (16 Gauge).
ii) Fire Door - 1 Hour rating : 0.80 mm thick (19 Gauge).
iii) General Purpose Door : 0.80 mm thick (19 Gauge).

C.R.Narayana Rao
Architects &Engineers 147 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Shutters shall be provided with the following :


i) No visible screws or fasteners on either face and Internal
reinforcement shall be provided at top, bottom and stile
edges for desired fire rating.
ii) Factory prepared shutter with pre-punched cutouts and
reinforcement pads to receive the approved type and make
of Hardware and Iron mongery.
iii) Pre-drilled hinge plates with hinge guard covers and
shutters with locks to have concealed lock box with lock
fixing brackets with pre-tapped holes and screws.
iv) Reinforcement pad at appropriate location to receive the
locks, Door closer, Panic Bar, etc as per the approved type
and make of Hardware and all as per manufacturers design
and conforming to Standards.
v) Necessary provision / fixing arrangements shall be
provided in the shutter as well as in the frame to receive / fix
the Electro magnetic latch, Electro magnetic contact for
hooter with reinforcement pads and in such a way to
connect the same to the card access control system / IBMS.

c) Infil material: Honeycomb paper core as infill material


and to be bounded to the inner faces of the shutter or as
per Manufacturers specification. Door should have been
tested with Infill material proposed by the manufacturer and
the same should have been approved by CBRI / BFRC.

d) Finish: Surface of the frame and shutter shall be


cleaned suitably & thoroughly with solvents and as per
manufacturers specification. Apply Zinc etch primer coating
as shop coat to receive additional coat of primer and top
coats, apply stove zinc phosphate primer (35 microns DFT)
as additional coat and finish the surface neatly with thermo
setting polyurethane paint (35 microns DFT) of approved
colour and make.

e) Installation : The frame and shutter shall be installed in


position as per the methdology described in the Technical
specification with necessary accessaries, tools & Plants etc.

f) Grouting: Frame shall be pressure grouted with cement


slurry 1:3 ratio or filling the pre cast solid block core to the
frame profile as approved. The surface after grouting shall
be neatly cleaned and to be ensured that there is no
scratch in the door frames after grouting.Back fill the frame
through holes provided and insert plug in type nylon plugs
after cleaning the surface and to suit the frame finish and
colour.

C.R.Narayana Rao
Architects &Engineers 148 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

G) Hardwares :
i) Vision panel : Providing and fixing Borosilicate single
clear toughened glass of Pyron or approved equivalent
make to the thickness of 6 mm to with stand two hours fire
rating including making cutouts in the steel door & fixing in
position with spin turned rings. Rate shall include for
providing one side adhesive Glazing tape in the frame to
hold the vision panel glass in position and to ensure the
stability of the fixing. One vision panel shall be provided in
the active leaf of the Single / Double leaf shutter.
ii) Hinge : Providing and fixing Stainless steel satin finish
double ball bearing butt hinges with SS screws of size 100
x 75 x 3 mm thick - Model No. SS 551 B - class 8 / 9 from
Dorma or approved equivalent make suitably for Single /
Double leaf door. Stainless steel conforming to SS 316 L
grade to BS 7352 or BS EN 1935-2002. 4 Nos for Single
Leaf Shutter and 8 Nos for Double Leaf Shutter.
ii) Flush Bolt : Providing and fixing Stainless steel satin
finish consealed tower bolt with SS screws of approved
equivalent make for Double leaf door in the In - Active leaf.

H) Provision :
i) Provision / fixing arrangements to be made in the shutter
as well as in the frame to receive / fix the Hinges, Locks,
Electro magnetic latch, Electro magnetic contact for hooter
with reinforcement pads and in such a way to connect the
same to the card access control system / IBMS.
ii) Refer hardware schedule enclosed for the details of
Mortise sash lock, Mortise dead lock, Handles, Push plates
and Panic bar etc. Necessary provision shall be made in
the frame and shutter to receive and fix the hardwares.
iii) Supplying Master key for the doors either floor wise or
wing wise as per the Master key plan including supplying
Grand Master key for all the doors.

Note :
1. All the Materials and hardware specifications proposed
for door shall conform to the codes, technical specification
and preamble to the bills of quantities.
2. Quoted rate shall be deemed to have considered all the
items covered in the specification and drawings, whether
explicitly stated or not.

a Fire Rated Steel - 2 Hr Rating

i Double Leaf Door


Sqm 65

ii Single Leaf Door


Sqm 125

C.R.Narayana Rao
Architects &Engineers 149 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

7.05 FIRE RATED STEEL DOOR HARDWARES

Extra rate over and above steel door items for providing and
fixing the following Hardwares in position in the doors
supplied with all necessary accessories etc complete and
as directed.

a Mortice Sash lock with lever handle on both sides with


internal thump turn and external key operation - Stainless
steel satin finish - 316 L grade of ST - 8100 with 752 lock
or Dorma or approved euivalent make with forend with Euro
profile cylinder Pc 93 with external key operation and
Internal thump turn and strike plate of Dorma make and Each 25
the strike plate shall be provided to suit the type of door
specified. (ie.Single/Double leaf). Stainless steel shall
conform to BS. (AHU Room and Other Servises )

b Mortice dead lock - Stainless steel satin finish - 316 L


grade of Model.no. Dead bolt 778 lock with escutcheon
and euro profile full cylinder Pc 91 with both side key
provision and strike plate of Dorma make and the strike
Each 35
plate shall be provided to suit the type of door specified.
(ie.Single/Double leaf). Stainless steel shall conform to BS.
Electrical Room.

e Rim panic latch with outside entry function - Model No.


PHA 2100 (A) - Function with Lockable Lever on outside
with euro Profile Cylinder and external key & Lever
Handle (one side) operation PHT 3905 of Dorma make. Each 10
and to be fixed in active leaf of the single/double leaf door .-
Staircase and Exit Door

f Automatic door closer Model No.TS 92 cam action G


(Push/Pullside) or B (Push/Pull side) EN 2 to 4 of Dorma
make. (Door closer shall be provided to suit the type of door
opening / opening policy specified. Ie. Double / Single leaf Each 35
and Push / pull side) with all other accessories.(To use
Shutter width upto 1100 mm)

h Pull Handle - D type of size and model as specified below


having - Stainless steel satin finish - 316 L grade of Dorma
make with SS screws / inside bolt fixing.

i Model.No. TGD1 450 22 S or approved equivalent


Each 35

ii Model.No.TGD1 300 22 S
Each 25

i Push plate of size 300 x 150 mm - 1.5 mm thick - Stainless


steel satin finish - 316 L grade of Model No.SP 006 A of
Dorma make or approved equivalent and with SS screws. Each 35

C.R.Narayana Rao
Architects &Engineers 150 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

7.06 Providing and fixing aluminium fixed cum sliding windows


fabricated as per drawing and fixed at all levels, elevations
and heights having a main frame work of vertical and
horizontals, out of specially designed approved extruded
sections to withstand the designed wind pressure and
loads. The extruded section shall be finished with
electrolylic colour anodised of approved colour with anodic
coating not less than 20 microns and the extruded
aluminium sections shall be of 6063 Alloy or BSH9
conforming to IS 63400.

Rate shall include to fix the main frames into masonry wall /
RC concrete surface with necessary clamps, fastening
straps, nuts, bolts, rivets, washers and other fastening
materials shall be in stainless steel or aluminium. Rate
shall include for providing clear toughened glass 5.5 mm
thick and to be fixed with snap fit aluminium beading section
and special water proof EPDM Gasket, Neoprene etc.
complete. Necessary silicon sealant of Dowcorning 795 or
approved equivalent make shall be provided at the
junctions between wall and main frames.

Rate shall include stainless steel safety clips to be provided


on each corner of glass as an additional safety to avoid
breakage of corner of the glass and also to be provided
with EPDM / Neoprene tripple barrier, extruded Reddiprone
weather strip to ensure water and air tightness and shall Sqm 24
include to conduct the performance test conforming to IS
Specification, etc. complete all as directed.

7.07 Providing and fixing of Aluminium grills in outerside of the


Aluminium windows, In Generall 63x37x2mm Aluminium
anodised tubler section at vertically 900 mm c/c horizontally
as directed by Architects or Engineers. Penals are covered
with 8mm thk auminium grills of 37mmx37mm fixing with
Sqm 60
aluminium anidised glazing clips with necessary rubber
gascut, etc. The rate shell be inclusive of necessary
hardwares and Aluminium L angle of 3mm thk for
connecting Aluminium frame work.

7.08 Providing and fixing aluminium fixed Ventilators fabricated


as per drawing and fixed at all levels, elevations and
heights having a main frame work of vertical and
horizontals, out of specially designed approved extruded
sections to withstand the designed wind pressure and
loads. The extruded section shall be finished with
electrolylic colour anodised of approved colour with anodic
coating not less than 20 microns and the extruded
aluminium sections shall be of 6063 Alloy or BSH9
conforming to IS 63400.

C.R.Narayana Rao
Architects &Engineers 151 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Rate shall include to fix the main frames into masonry wall /
RC concrete surface with necessary clamps, fastening
straps, nuts, bolts, rivets, washers and other fastening
materials shall be in stainless steel or aluminium. Rate
shall include for providing clear toughened glass 5.5 mm
thick and to be fixed with snap fit aluminium beading section
and special water proof EPDM Gasket, Neoprene etc.
complete. Necessary silicon sealant of Dowcorning 795 or
approved equivalent make shall be provided at the
junctions between wall and main frames.

Rate shall include stainless steel safety clips to be


provided on each corner of glass as an additional
safety to avoid breakage of corner of the glass and also
to be provided with EPDM / Neoprene tripple barrier,
extruded Reddiprone weather strip to ensure water and Sqm 5
air tightness and shall include to conduct the performance
test conforming to IS Specification, etc. complete all as
directed.

7.09 Providing and fixing welded M.S. grills to details as per


drawing for windows / ventilator openings with necessary
screws, bolts and fixed with necessary M.S. lugs
embedded in masonry with C.C. 1:2:4 and finishing the
surface neatly. Rate shall include for two coats of first Kg 450
quality synthetic enamel paint over a coat of zinc
phospate primer, necessary tools & plants, welding and
consumables, etc. complete, as directed.
7.10 Supplying and fixing M.S handrail in the staircase / parapet
walls fabricated using 50 mm dia 16 G pipe bent to shape
and pattern at top with 32 mm dia MS pipe as verticals at
600 mm c/c, 3 Nos 20 mm dia MS pipes as horizontal ties,
fixing 12 mm MS plate of size 150 mm x 170 mm at the
sides of steps 12 mm dia HILTI make anchor fasteners 150
mm long with necessary welding for fixing the pipe for 1000
mm high including of routing of package and all as directed
(please refer the drawing).Rate shall include necessary
tools and plants painting the same with one coat of red Rmt 60
oxide paint and two coats of synthetic enamel paint
complete as directed.Rate also to include removing all the
flux and grinding the MS exposed edges
smooth.Measurements will be taken for RM containing the
above material specified and not individually. Pl. refer
Drg.No SDB1-A10-02 which is atached.

C.R.Narayana Rao
Architects &Engineers 152 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

7.11 Providing and fixing of Aluminium subframe of size 15 x 62


mm conforming to PAL section No.442548 - 0.794 kg/M or
equivalent Indal Section of approved colour with anodic film
of not less than 20 microns thickness including fabrication
and fixing of necessary holdfast with a coat of anticorrosive
primer for the hidden surface on the burried under masonry
wall / hollow block wall / solid block wall / RC concrete etc.
Rmt 120
Rate shall include necessary chasing in walls for fixing
clamps, holdfasts and finishing the surface smooth after
fixing of subframe including making good surface as
per original condition etc. complete, as directed.

7.12 Supplying and fixing extruded aluminium anodised with


anodic coating not less than 20 microns storm proof louver
of consisting of heavy duty louver made out of extruded
aluminium anodised louver blades with pitch of 30 mm of
"Bhoruka Extrusions" having 2 mm thick profile to shape as
per drawing and the blades set at 45 deg angle at spacing
of 30 mm as per drawing with aluminium box frame alround
of size 63.5 x 38.1 mm suitable size of `C' channel to fix
Louvers with necessary stiffeners fitted into wall / RC
surface using anchor fastners. The louver should be fitted
into the aluminium box using screws and necessary Sqm 48
accessories etc. complete. Rate shall include for providing
and fixing aluminium box frame in addition to the louver box
frame, so as to terminate the composite panel cladding into
the box frame in the jambs and providing Aluminium
anodised Flat of size 25x25 mm - 3 mm thick alround frame
to protect the system from rain water entry through the
sides, tools and plants, required etc. complete as directed.

7.13 Providing and fixing pull and push type rolling shutters of
approved make out of 18 gauge, 75mm wide cold rolled
steel laths of convex corrugation, with side guides and
bottom rails, with interlocking arrangements for steel laths
by means of alternate clips, suspension shaft with High
tension coil type springs two numbers, mounted on
specially designed pipe shaft, with bracket plater, guide
Sqm 91
channels, ball bearing arrangements, for inside and outside
lockign with push and pull operation complete including
pulling hooks, 4 nos. handles with all fittings and
accessories, painted with a coat of red lead paint (without
top cover) cost of materials, labour, HOM of machinery
complete as per specification.

C.R.Narayana Rao
Architects &Engineers 153 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

8.00 INTERNAL AND EXTERNAL FINISHES


8.01 Plastering of walls with cement mortar 1:4, 20 mm thick with
a neat floating coat of cement for smooth finish according to
specifications. Rate shall include for providing G.I.chicken
mesh made out of galvanised iron of nominal thickness
0.35 mm with a Zinc coating of 120 gms per Sqm at the
junctions of masonry and concrete works to a width of 100 Sqm 1000
to 125mm including tying in position with suitable
clamps/screws,necessary staging,scafolding and curing at
all levels and elevations etc.complete as directed.

8.02 Plastering of R.C walls, peripheral beams and columns with


CM 1:3, 12 mm thick with a neat floating coat of cement for
smooth finish according to the specification. Rate shall
include for providing G.I.chicken mesh made out of
galvanised iron of nominal thickness 0.35 mm with a Zinc
coating of 120 gms per Sqm at the junctions of masonry Sqm 5900
and concrete works to a width of 100 to 125mm including
tying in position with suitable clamps/screws,necessary
staging,scafolding and curing at all levels and elevations
etc.complete as directed.

8.03 Plastering of ceiling including slabs, beams and column


drops and staircase waist slabwith CM 1:3, 6 mm thick with
a neat floating coat of cement for smooth finish according to
the specification. The rate shall include necessary Sqm 4700
scaffolding, form work and curing etc. complete all as
directed.

8.04 Plastering for external surfaces with base coat of 20 mm


thick in C.M 1:4 with water proofing compound of CICO
No.1 or equivalent as per Manufacturer's Specification and
finishing coat of 10 mm thick in C.M 1:3 after roughening
the surface of first coat in green condition with wire brush
and clearing of loose particles with sponge finish (washed Sqm 9200
sand finish) all complete as per specification and as
directed. Rate shall include for providing drip bands /
moulds / grooves to any size and shape as directed.

8.05 Providing 15 mm thick water proof plaster in Toilet internal


walls and over head tank with CM 1:3 with water proofing
compound of CICO No:1 or equivalent as per
manufacturers specification and roughening the surface in Sqm. 350
green condition with wire brush and clearing of loose
particles with sponge brush (washed sand finish)

8.06 Applying white washing three coats to ceilings and walls


with pure shell lime or fat lime conforming to IS-712 all as
per Specification and as directed. For shaft , lift interior Sqm 10600
walls.

C.R.Narayana Rao
Architects &Engineers 154 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

8.07 Providing two coats of first quality water proof cement paint
of approved make and colour over a priming coat of white
colour water proof cement paint or any primer specified by
the manufacturer including preparation of surface by
Sqm Qro
thorough cleaning and wetting before painting and curing all
as per manufacturer`s specifications and as directed.

8.08 Providing two coats of BELCO- Acrylic emulsion paint of


Egg - Shell Finish (Supreme 3 in1of Dulux) to walls of
approved colour over a coat of Dulux Cement Primer
(solvent based) - 34-200 of ICI make, including
preparation of surface by thorough cleaning and free from
grime, dust, grease, loose or flaking particles, if any Sqm 1350
haircracks shall be filled, smoothenout the surface by using
ICI Readymix Water Filler (33-500) followed by a coat of
water based cement primer - (32-168) as per
manufacturers specification fully to give an even shade
before painting as directed.
8.09 Providing three coats of 'PLASTIC 'emulsion paint to walls
/ ceiling of approved colour over a coat of water based
primer including preparation of surface by thorough
cleaning and wetting and applying POP/Gypsum powder Sqm 9200
putty as per manufacturers specification fully to give an
even shade before painting and curing as per
manufacturers specifications and as directed.

8.10 Supplying and applying "RENOVA" Synthetic plaster over


the prepared plastered surface at three coats. The first coat
of application to be done with Renova ASP by trowel. The
second coat with brush and the final coat should also be
applied with brush. The rate shall include for carrying out Sqm 10600
work at all levels, all necessary surface preparation, tools,
scaffolding, taxes etc., all complete. The rate also includes
all colour shades, texture and as pattern per manufactures
shade card.

8.11 Painting with lustre paint of approved shade and colour of


ICI / Asian Paint or equivalent make, by sand papering the
surface, then applying a coat of primer, then applying two
coat of putti, again sand papering the surface and applying
the coat of paint with roler finish as per Manufacturers Sqm Qro
specification and as directed. Rate shall include for
preparation of surface, scaffolding if any, and cleaning the
surface after applying etc. complete, and as directed.

C.R.Narayana Rao
Architects &Engineers 155 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

9.00 WATER PROOFING WORKS


NOTE: Specialized agency to be approved by Client /
Consultants. PRINCIPAL MANUFACTURER SHALL GIVE
GUARANTEE FOR STIPULATED TIME FOR THE
WATERPROOFING WORKS DONE AT SITE. All surfaces
to be waterproofed should be sound, clean and dry.
Concrete surfaces should have a light steel-trowel followed
by a fine hair-broom or equivalent finish, which is dry and
free of dust, oil and other contaminants. All high spots
should be removed. Moss and lichen must be removed
physically followed by treatment with fungicidal wash to kill
any spores and inhibit further growth.

After treatment wash down thoroughly with clean water and


allow to dry. Grouting periphery of spout pipes with water
insensitive epoxy, pressure grouting of construction joints
and honey comb areas with cement grout, proper
preparation of the concrete surface by mechanical
means/hydro blasting to ensure a good bond between the
topping and the substrate,Testing of the surfaces prior to
start the work,after completion and after a period of one
month after completion by ponding,grouting or sealing of
joints,making vatta at corners/junctions etc are deemed to
be included for all items while quoting rates Contractor
shall give both material and preformance guarantee in the
approved format.
9.01 Treatment on PCC levelling course below raft slab, lift
pits, Junctions of retaining and raft slab of main
building etc. covering the following sequence of operation :

a) Providing, supplying, mixing, laying cement screed


plaster 20 mm thick in cement concrete slurry 1:2:4 mixed
with 6mm & down grade course graded aggregate with
water proofing compound like CICO NO:1 (normal setting
integral water proofing compound) or approved equivalent
conforming to IS at the rate specified by the manufacturer
over PCC levelling course at any depth & height.

b) Providing, supplying, mixing, applying two coats of ready


to use two component Acrylic polymer modified cement
based, flexible, water proofing slurry like TAPECRETE or
approved equivalent to a thickness of 2 mm over the
plastered surface of operation above.

C.R.Narayana Rao
Architects &Engineers 156 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

c) Providing and laying water proofing treatment with


Membrane type water proofing methods using polymer
modified Bituminous membrane of CICO shield /Build
Wrap/ Deboer make or approved equivalent make. The
Atactic Poly-Propylene (APP) membrane shall have UV
resistant property, ground chemical resistant, high melting
points, flexible and elastic with high adhesive strength. The
membrane shall be reinforced with non woven polyester
reinforcement of minimum of 180 g/sqm and reinforced with
glass fibre grill of 8 g/sqm including coating with compatible
primer of Bituminous base whereever it is required and
torch application with overlap of 70 - 100 mm wherever
required. Cost to include laying by loose and torching the
prefabricated overlap at ends. The membrane surface shall
be procted with granules.

d) Providing, supplying, mixing, laying cement concrete


screed 40 mm thick with CC slurry 1:2:4 mixed with 12mm &
down grade course graded aggregate with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth & height.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 3000
plants, mixing device and gauge,Shuttering etc.complete as
per manufacturer's specification and as directed.

9.02 Providing chemical injection in the form of pressure grouting


to the raft slab, base slab of Lift pit, retaining walls of
basement lift pit from interior surfaces works at any depth,
height and level by injecting cement slurry mixed with grout
with CICO non shrink grouting compound or approved
equivalent admixed with cement slurry in the required
consistency through the prefixed GI nozzles in the 18mm
dia holes drilled in grid pattern at a spacing not exceeding 1
metre c/c on the top of base slab/retaining wall & surfaces
under pressure using grout pump. Nozzle fixing and
grouting for a retaining wall shall be only at construction
joints and honeycomb areas on approval.

C.R.Narayana Rao
Architects &Engineers 157 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Rate shall include for preparation of surface, de-watering,


drilling holes, using pneumatic hammer for fixing of GI
nozzles to the required depth, grouting admixture and finally
cutting the projected nozzles and sealing of the GI nozzles
after injection operation is over with CICO NO:3 quick
setting material or approved equivalent admixed with
cement, finishing, curing, etc., as per manufacturers
specification. Rate shall include for preparation of surface
by mechanical upgrading to remove all loose mortar and
laitance, oil, grease etc. and washing the surface with water
to get neat surface, dewatering, finishing, curing,
scaffolding, waterproofing chemicals, wastage,
conveyance, tools and plants, mixing device and gauge,
shuttering, Nozzles etc. complete as per manufacturer's
specification and as directed.

Mode of measurement:
Note : Item no. a) Top of raft slab of basement lift pit base
slab and UG sump base slab ie. width and length between
the retaining wall only will be measured and paid for.

Note : Item no. b) Grouting carried out on the vertical


surfaces(Internal) of the Retaining wall of the basement, lift
pit & UG sump will be measured and paid for.

a Raft slab & lift pits Sqm 500


b Retaining walls of basement Sqm 750
9.03 Treatment to side wall of varying thickness of basement
floor, Lift pit, of main building from exterior surface covering
the following sequence of operations :

a) Providing, supplying, mixing, applying two coats of ready


to use two component acrylic polymer modified cement
based flexible water proofing slurry like TAPECRETE or
approved equivalent conforming to IS to thickness of 2
mm on the surface of side wall prior to the chemical
injection treatment is completed as specified under item
above.

b) Providing and laying water proofing treatment with


Membrane type water proofing methods using polymer
modified Bituminous membrane of CICO shield /Build
Wrap/ Deboer make or approved equivalent make. The
Atactic Poly-Propylene (APP) membrane shall have UV
resistant property, ground chemical resistant, high melting
points, flexible and elastic with high adhesive strength. The
membrane shall be reinforced with non woven polyester
reinforcement of minimum of 180 g/sqm and reinforced with
glass fibre grill of 8 g/sqm including coating with compatible
primer of Bituminous base whereever it is required and
torch application with overlap of 70 - 100 mm wherever
required. Cost to include laying by loose and torching the
prefabricated overlap at ends. The membrane surface shall
be procted with granules.

C.R.Narayana Rao
Architects &Engineers 158 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

c) Providing and laying solid block 150mm thick using


cement mortar 1:3 with 75mm thick RC band @ every 1m
intervals with nominal reinforcements of 3 Nos of 8mm dia,
over the APP membrane as directed.

d) Providing, supplying, mixing, laying cement plaster 15


mm thick with cement mortar 1:4 mixed with approved water
proofing compound like CICO NO:1 or equivalent
conforming to IS at the rate specified by the manufacturer
over the coated surface of operation specified in point no.
(a) above.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 750
plants, mixing device and gauge, shuttering, Nozzles etc.
complete as per manufacturer's specification and as
directed.

9.04 a Water proofing treatment over RCC roof slab laid to slope in
terrace and gutter slab covering the following sequence of
operation and specifications:
a) The roof slab laid in slope / gutter slab shall be
thoroughly cleaned by removing the debris and dust, to
receive the water proofing treatment.

a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)
b) Applying 2 coats of acrylic polymer modified cement
based, flexible water proofing slurry like TAPECRETE or
approved equivalent make to a thickness of 2mm and cured
for 7 days and as per manufacturer's specification.

C.R.Narayana Rao
Architects &Engineers 159 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

c) Supplying, providing and applying water proofing


treatment with Membrane type water proofing methods
using polymer modified Bituminous membrane of CICO
shield/ Build Wrap/ Deboer or approved equivalent make.
The Atactic Poly-Propylene (APP-4mm th)membrane
having UV resistant, ground chemical resistant, high melting
point more than 110 deg. C, flexible and elastic with high
adhesive strength. The membrane shall be reinforced with
non woven polyester reinforcement of minimum of 180
g/sqm and reinforced including coating with compatible
primer of Bituminous base and torch application with
overlap of 100 mm wherever required. The reinforcement
provided shall be able to withstand the traffic flow density
during & after construction and shall carry a minimum
guarantee period of 10 years. Cost to include applying the
primer and torching the entire surface and also
prefabricated overlap at ends. The membrane surface shall
be protected with granules.

d) Providing, supplying & laying extruded polystyrene rigid


foam panel of size600 x 1200mm-75mm thick of formula
R.Metric-FM 50 having a density of 24 kg/cum and
compressive strength not less than 250 kpa of ownes
corning or approved equivalent make having exeptional
mechanical properties like resistance to the diffusion of
water vapour, resistance to water absorption, uniform
density distribution, dimensional stability, very high
compressive strength, aging resistance and also immunity
against insects, pets, bacteria, rodent attacks and micro
organisms etc., for over deck insulation including necessary
skin shiplap joint,anchores,adhesives, primers etc., as
required for proper fixing etc., complete all as per the
manufacturers specifications & consultants approval. The
extruded polystyrene panel has closed sealed cells
structure linked to one another is produced by a contineous,
fully automated extrusion process in accordance with
international specification and standard etc. all complete.

f) Laying fibre glass cloth over the extruded polystyrene


rigid foam panel.

g) A layer of 20 mm thick cement mortar 1:4 admixed with


CICO NO - 1 (normal setting integral water proofing
compound) or other approved equivalent make compound
shall be spread over the operation specified in point (f)
above and laying brickbat coba over the surface 40mm
thickness at drain point and required thickness at ridge and
the top surface of the brickbat coba shall be plastered with
cement mortar 1:4, 20 mm thick admixed with CICO NO:1
@ 2% by the weight of cement and add RECRON 3S 225
per bag of cement and draw false line of 300 mm X 300 mm
over the finished surface. (The rate shall be quoted for an
average thickness of 110 mm).

C.R.Narayana Rao
Architects &Engineers 160 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface,dewatering, finishing, curing, scaffolding, supply
and adding water proofing chemicals at the specified
proportion as per manufacturer's specifications, all
materials, wastages, conveyance, tools and plants, mixing Sqm 6000
device and gauge, shuttering and also include for
conducting leakage test at terrace by storing water on the
terrace for about 25 mm depth continuously for a period of 7
days etc.complete, as directed.

b Extra rate over and above item, for Providing and laying
brickbat coba using well burnt brick bats set in cement
mortar 1:3 by adding CICO no.1or approved equivalent Cum 600
water proofing compound including curing etc complete as
directed

10.00 MISCELLANEOUS WORKS

10.01 Providing and fixing in position single component, self


sealing water swelling bars made up of flexible polymer
composites at construction joints of retaining walls and
water retaining structures and wherever specified with
proper overlaps at joints of approved makes as per
consultants approval

a Syncoflex make (25 x 25) Rmt 225

b Masterflex 610 of BASF makes

10mm x10mm Rmt 50


10.02 Providing and fixing in position Laminated Neoprene
bearing pad confirms to IRC:83(Part II) 1987 of shore
hardness 60 and Steel laminates of 3mm thickwith equal
thickness elastomer in between at all junctions/levels of
beams wherever specified by Consulting Engineers. Cost to
include 20 mm dia MS bar of 100 mm length each side
welded to the steel laminate,MS pipe sleeve of 25 mm dia
with a cap to cover the rod on one side,necessary
arrangements for embedding in concrete to the required
line,level etc,complete

a 100 mm X 100 mm X 40 mm No. 25


10.03 Providing and laying of light weight concrete fill on structural
slab using Vermiculite cement based composition having
physical elasticity , chemical inertness, firm adhesion, fire
resistance with thermal / acoustic insulation properties, anti-
corrosion, anti-condensation, etc in the required proportion
to get the desired density, mixing, transportation, placing,
compacting and finishing to the required level with
necessary side supports, equipments, etc complete.

a 600 kg/ Cum density Cum Qro

C.R.Narayana Rao
Architects &Engineers 161 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

10.04 Extra rate over plaster item rate for providing Plaster mesh
made out of galvanised iron of nominal thickness 0.35 mm
with a Zinc coating of 120 gms per Sqm at the junctions of
Masonry and concrete works to a width of 100 to 125 mm
including tying in position with suitable clamps / screws etc.,
complete and as per manfacturer specification,from M/s.
Arpitha exports, Bangalore. Rate shall include for
preparation of surface, cleaning, curing etc. complete, all as
directed. as directed.

Note : This item shall be operated only for doing chipping


and chasing done for services, embedding the pipes /
conduites, if specifically ordered, since the plastermesh
shall be provided within the quoted rate of plastering items. Rmt 50 -
Provision of mesh for regular junction and similar materials
shall not be measured for payments.

10.05 Providing and laying sand layer in the trenches, drainage


systems or any specified works for full width and alround
the pipes as indicated in the drawing. Cost to include Cum Qro
necessary compaction etc., complete.

10.06 Providing and laying 20mm size grade aggregate for any
specified works with the specified width and depth as
indicated in the drawing, cost shall include necessay lead Cum Qro
and lift etc., complete.

10.07 Providing and laying in position the RCC humepipes(NP2)


of approved quality and make including collars,.necessary
Excavation, PCC 1:2:4 supports, Sand cushion of 150mm
on all sides, Refilling with earth, Compaction and making
good the level, alignment etc.,complete

a 450 mm dia Rmt 25


b 300 mm dia Rmt 25
c 150mm dia Rmt 25

Total C/o.to Summary of 3 D in Rs..

C.R.Narayana Rao
Architects &Engineers 162 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.00 SECURITY BUILDING

EARTH WORK EXCAVATION


GENERAL NOTES FOR EXCAVATION
Contractor shall take all required permissions from the
appropriate authorities for Excavation, Blasting, Carting
away materials including depositing, levelling etc. and shall
bear all the expenses for the same.
Rate includes removal of all kind of vegetation,small shrubs
etc. Dewatering water to be let out of the building / site area
through proper pipes & channels if required. The contractor
at his own expenses shall water very well, ram and
thoroughly consolidate the bottom of all excavations &
ground before the construction of foundation/footing/plinth
beam, filling in basement floor or other work is
commenced.The rate for excavation shall include for
shoring sides or trenches with approved timber/steel
accessories wherever necessary to prevent sides from
falling including bailing or pumping out of water if necessary
and include If there are any shrubs, bushes, trees, roots of
the trees to be removed for min depth 50. Necessary Lift &
lead for all type of excavated materials to convey them and
to deposit them as directed by the engineer-in-charge are to
be considered.

Contour level to be taken jointly with the engineer-in-charge


and prior written approval to be taken before starting any
excavation/ filling at every 3 / 5 mt grids or at regular
intravels as directed by the engineer -in-charge for arriving
at the actual quantity. Measurements for filling will be taken
for consolidated thickness only.Cost to include all and
necessary royalty and other permission charges required to
execute the works.Unless noted otherwise measurements
shall be considered to the edge of PCC only.

Note: The measurements shall be based on the levels


captured prior and after execution. And in case of stack
measurement, the percentage of 40 % of voids to be
deducted from stack measurement for hard rock (Incase
operated). Blasting shall be carried through licensed
operator having valid blasting licence.

C.R.Narayana Rao
Architects &Engineers 163 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.01 General Excavation by mechanical means in all types of soil


including dense soil, discentegrated/ weathered/ soft rock
for any type of foundation including necessary manual
excavation for dressing the edges & leveling, all leads and
lifts back filling in layers of 150mm with watering and
compaction to the required proctor density . Rate to include
disposing the excess earth and spreading in layers to the
required levels within the site wherever
specified,dewatering of both ground and surface water, Cum 5
removal of slurry generated while excavation and keeping
the area free of water with necessary shoring, struting,
required for keeping earth in position etc,. excavating loose
pockets and compacting the same. Note: Aut
working space and Provision of slopes if required for
execution shall not be paid separately.
Excavation in all types of soils to any depth below ground
level.
2.02 Excavation in Medium rock ( more than 1/2 Cum in size -Un-
poclainable) to the required level & depth (Mass
excavation) including all leads and lifts, stacking excavated
material within plot at approved location , if required de-
watering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
of water with necessary shoring, strutting, stepping, Cum 5
dressing, grading required for keeping earth in position etc.
as per detailed specificationand conforming to safety rules
during progress of the work. Note:Authorised working
space and Provision of slopes if required for execution
shall not be paid separately.

2.03 Same as item No - 1.01 but for general excavation in Hard


rock/ boulders (more than 1/2 Cum in size -Un-poclainable)
by chiselling/ wedging to the required level & depth (Mass
excavation) including all leads and lifts, stacking excavated
material within plot at approved location , if required de-
watering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
of water with necessary shoring, strutting, stepping, Cum 30
dressing, grading required for keeping earth in position etc.
as per detailed specificationand conforming to safety rules
during progress of the work. Note:Authorised working
space and Provision of slopes if required for execution
shall not be paid separately.

C.R.Narayana Rao
Architects &Engineers 164 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.04 Excavation in hard rock / boulders (more than 1/2Cum in


size) by Controlled Blasting using explosives and trimming
to required level for foundation, trenches, rafts, plinths,
leveling area etc. to the required depth at all leads including
stacking excavated material within plot at approved
location, if required bailing /pumping out of water to keep
site dry at all times until completion of work; shoring, Cum 30
strutting, stepping, dressing, grading, cleaning, removing
and excavating loose pockets as directed etc. all complete
as detailed in specification and conforming to safety rules of
authority from time to time and Explosives rules1940 or as
amended.

2.05 Carting away surplus earth/excavated material/debris and


like materials outside the plot not covered under above
items 1.01 to 1.04 all above items and disposing off the
same to the designated areas to the lead around 10 KM
identified by the local authorities/engineer-in-charge for Cum 70
dumping of such material,including spreading,compacting
etc.,as per the norms by the local authorities.

2.06 Supply and filling in foundations and the area wherever


specified with approved good quality filling materials in
plinths, sides of retaining wall alround the building ( i.e
backfilling ) area development etc. wherever specified in
layers of not exceeding 150 mm thick including breaking
clods,storing,transportation ,double handling, watering,
compacting each layer with vibratory compactor and at
unaccessible places with wooden/steel rammers to achieve
90 to 95% proctor density at optimum moisture content, all
leads and lifts, bailing/ pumping out of water to keep site dry
while backfilling; cost shall include conveyance of all
materials, labour, machinery etc. complete as directed.The
rate to include loading,unloading, hire and fuel charges for
tools and plants and other incidental charges etc., complete
as directed.

a With approved quality murrum brought from outside. Cum 5


b Approved quality river sand brought from outside Cum 5
c With approved quality quarrydust brought from outside Cum 5
2.07 Providing and laying in position 150mm thick soling with
approved Base preparation by Mechanical compaction,
using hard granite stones / Rubble and smaller pebbles for
void filling, moorum for binding as directed by the Engineer-
in-charge including watering,packing, compaction etc., with Sqm 5
required tools and plants and all lead,lift, conveyance as
required etc., complete as directed.

C.R.Narayana Rao
Architects &Engineers 165 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

2.08 ANTI-TERMITE TREATMENT WORKS


Providing Anti termite treatment in accordance with
stipulations laid down by IS 6313 - part II by approved
agency with min of 10 years of guarantee including the cost
of chemical,precautionary measures etc.complete along
retaining walls only for a width of one meter or as specified
by consultants (treatment for floor is not required and
Sqm 25
agency shall be approved by engineer-in-charge
Note: External periphery length of the retaining wall
multiplied by 1 M will be considered as the measurement
area.

3.00 PLAIN & REINFORCED CEMENT CONCRETE WORKS


3.01 Providing and laying plain cement concrete 1:4:8 using
coarse graded aggregate of 40 mm and down size for
levelling course under footings, steps, walls, platform etc. Cum 2
including form work wherever necessary and well
compacted etc. all complete, as directed.

3.02 Providing and laying P.C.C. 1:3:6 of specified thick


wherever specified using river sand, 20mm and downsize
metal including base reperation, Compaction, levelling, all Cum 4
leads and lifts, curing and shuttering if necessary etc.,
Complete
3.03 Providing and laying P.C.C. 1:2:4 of specified thickness
wherever specified using river sand, 20mm and downsize
aggregate including cleaning,subgrade preparation,
Compaction, levelling, all leads and lifts, rough finishing at
the top surface,curing and shuttering if necessary etc.,at all
heights and depths as instructed.

a DPC, Copings, Flagging concrete, shaft screed etc., Cum 2

READY MIX CONCRETE / CONTROLLED CONCRETE


NOTE: RMC SHALL BE PROCURED FROM SITE
BATCHING PLANT HOWEVER, IN CASE OF READY MIX
CONCRETE PROCURED FROM RMC PLANT THE
PROBABLE CONCRETE CAN BE FETCHED FROM (L&T/
IJM / Redimix).
Providing, batching, mixing, transporting through transit
mixers, pumping and laying controlled Reinforced Cement
Concrete of specified grade at all levels and heights
specified below using ordinary Portland cement of grade 53
from approved manufacturer, river sand, 20mm and down
size coarse aggregates, necessary Mineral admixtures
approved by Consultants (elkem and Conplast SP 430SRV
from Fosroc or equivalent), including all leads and lifts,
pumping using line pump or boom placer, vibrating/
compaction, scaffolding wherever necessary, curing as
directed, excluding cost of shuttering and reinforcement
works.

(Design mix shall be as approved by the Structural


Consultant / Employer's representatives

C.R.Narayana Rao
Architects &Engineers 166 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.04 M30 Grade


Columns at
Ground floor Cum 2
Flat slabs
Terrace Floor Cum 5
Beams
Terrace Floor Cum 2
M30 GRADE CONCRETE
3.05 RCC Parapet at all levels of specified thickness Cum 1
Footings/ Rafts for columns,Core walls/ Retaining walls Cum 5
a etc.,
b Plinth Beam Cum 2
c Grade slab Cum 3
d Staircase at all floors & heights Cum Qro
e Lintels at all levels Cum 0.5
f RCC Brackets/Fins/Ledges/lofts at all levels Cum 0.5
g Pedestals , foundations for Equipments Cum Qro
3.06 Supplying, drilling and fixing MS anchor rod of 16 mm dia
into the hard rock for 200 mm below footing and 200 mm
anchoring into the footing.Rate shall include for material for Nos Qro
Cement grouting and labour etc, complete

3.07 M25 Grade Concrete


a. RCC Parapet at all levels of specified thickness Cum Qro
b Lintels at all levels Cum Qro
c RCC Brackets/Fins/Ledges at all levels Cum Qro
d Cill concrete/Fins /Chejjas/Lofts at all levels Cum Qro
3.08 M20 Grade Concrete
a. RCC Parapet at all levels of specified thickness Cum Qro
b Lintels at all levels Cum Qro
c RCC Brackets/Fins/Ledges at all levels Cum Qro
d Cill concrete/Fins /Chejjas/Lofts at all levels Cum Qro

C.R.Narayana Rao
Architects &Engineers 167 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.00 FORM WORK


4.01 Providing, fabricating and erecting form work at all levels
and places wherever needed/specified as per drawing
including striking with 12mm Plastic coated, marine
resistant waterproof ply/Smooth finished MS plates with
adjustable steel props of acceptable Staging system and
with sufficient bracing as approved by consultant. Cost to
include designing of proper form work and staging system
to suit the requirements,Submission of design calculations
and shop drawings for approval,sealing the joints with
heavy duty brown self adhesive tape, aligning to line and
levels including M.S. Ties, PVC Spacer, Providing
openings/ cutouts/ pockets, applying deshuttering chemical,
Deshuttering as approved by the consultant etc., complete
at all levels, double/tripple heights and profiles for Note :
Only plan area shall be considered.No extra shall be paid
for Side shuttering of Drop panel/column capitals.

1) plywood shuttering shall be considered for all vertical


elements, beam soffit, corewalls, stairs, ramps, tanks,
RCCpedestals Etc.,
2) M.S. plates shall be considered for foundation,slabs
only.
3) Shuttering & deshuttering sequence shall be 100%, 80%
& 40% from the slab to be cast respectively
a Columns at

Ground floor Sqm 20


Flat slabs at all levels
Terrace Floor Sqm 30
Beams at all levels

Terrace Floor Sqm 25

4.02 RCC Parapet at all levels of specified thickness Sqm 10


4.03 Footings/ Rafts for columns,Core walls/ Retaining walls
Sqm 14
etc.,
4.04 Plinth Beam Sqm 20
4.05 Grade slab Sqm 2
4.06 Staircase at all floors & heights Sqm Qro
4.07 Lintels at all levels Sqm 5
4.08 RCC Brackets/Fins/Ledges at all levels Sqm 5
4.09 Pedestals , foundations for Equipments Sqm Qro

C.R.Narayana Rao
Architects &Engineers 168 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.10 Providing, fixing reinforced cement concrete precast slab


with controlled cement concrete - M20 grade using coarse
graded aggregate 20 mm and downsize. Rate shall include
for providing necessary casting platform, shuttering,
finishing the exposed faces smooth wherever necessary
and pointing the joints with C.M 1:3, 15 mm thick curing
and fixing in position etc complete and as directed. Rate
shall include for fixing MS angles of required size based on
the thickness of precast slab and to be fixed on the edges
of the precast slab including grouting the lugs with Cement
concrete 1:1.5:3, GI Hooks for lifting the slab etc complete,
as directed. Necessary reinforcement MS angles,MS
lugs,GI hooks will be paid seperately in the respective
items.

a 100 mm thick Sqm 10


b 75 mm thick Sqm 10
4.11 Providing and fixing precast reinforced cement concrete jalli
work, with controlled cement concrete - M - 20 grade using
coarse graded aggregate of 6 mm and downsize as per
drawing including fixing in position with cement mortar 1:3.
Rate shall include for cost of form work wherever required
and cost of nominal reinforcement with 8mm dia.-Fe 415
steel at required spacing confirming to IS standards and
specification etc complete and as directed.

a. 100 mm thick Sqm 5

5.00 IRON & STEEL WORKS


5.01 Providing and fixing reinforcement for RCC work with
Thermo mechanically treated (TMT) bar of various
diameters and grade of steel as specified below conforming
to IS or equivalent BS specification including cutting and
waste, bending, hoisting, fabricating and placing in position
according to drawings and binding the reinforcement with
galvanised annealed binding wire of double fold of 18
gauge and providing PVC cover blocks for placing the
reinforcements in position and for maintaining the cover
specified and/or according to relevant IS or equivalent BS
code.

C.R.Narayana Rao
Architects &Engineers 169 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Note : Unless noted otherwise the measurements in


accordance with IS 1200 or equivalent BS. However
reinforcement shall be measured only in lengths of bars as
actually placed in position on standard weight basis, no
allowance being made in the weight for rolling margin.
Authorised laps and splices, Chairs of any shape & profile,
Spacer bar of any shape & profile, cover block, wastage
and binding wire will not be measured and shall be included
in the quoted rates.Quoted rate shall be deemed to have
considered the above stipulation.Quoted rate to include
lead, lift, placing at all levels and as directed. Detailing of
the reinforcement shall be ductile detailing for seismic
zone III as per codal requirement.

I Grade of reinforced steel - Fe 500 MT 1.25

6.00 MASONRY WORKS


6.01 Providing and constructing brick work with best quality
well chamber table moulded bricks with minimum
compressive strength of 50 Kg per Sqcm in cement mortar Cum 5
1:5 in foundation and basements, etc. complete, all as
directed.

6.02 Providing and constructing brick work with best quality well
chamber table moulded bricks with minimum compressive
strength of 50 Kg per Sqcm. in cement mortar 1:5 in Cum 5
superstructure at all levels etc. complete, all as directed.

6.03 Providing and constructing 115 mm thick masonry wall at all


levels with approved best quality well chamber burnt
moulded bricks with minimum compressive strength of 50
Kg/Sq.cm in cement mortar 1:4 with M20 reinforced cement
concrete binders - 80 mm thick laid horizontally to the full
length of the wall at 1000 mm ctc using coarse graded
aggregate of 12 mm and downsize and reinforced with 8
mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm dia for Sqm 100
stirrups at 200mm centres using Fe 500 grade steel. Rate
shall include for cost of reinforcements and tying in postion
using binding wire made out of 16 gauge GI annealed or 18
gauge SS, form work, scaffolding, raking out joints, curing
etc complete and as directed.

6.04 Providing and constructing cement concrete solid block


masonry work at all levels in cement mortar 1:3 using
standard size of 400 x 200 mm of solid cement concrete
blocks of thickness as specified below having compressive
strength of 5.5 N/ sqmm including all scaffolding, staging,
curing, all lifts etc. complete and as directed as per the IS
relevant standards. Concrete blocks manufactured under
strict quality control conditions using modern rugged block
casting and stripping machine with the latest moulding
techniques etc. only shall be used.

C.R.Narayana Rao
Architects &Engineers 170 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

a. 200 mm thick wall Sqm 120

b. 150 mm thick wall Sqm Qro

c. 100 mm thick wall Sqm Qro


6.05 Extra rate over & above Solid / Hollow Masonry wall for
providing R.C.Binders of 80 mm thick laid horizontally to
the full length of the wall at 1000 mm ctc using coarse
graded aggregate of 12 mm and downsize and reinforced
with 8 mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm
dia for stirrups at 200mm centres using Fe-500 grade steel,
including cost of reinforcements and tying in postion using
binding wire made out of 16 gauge GI annealed or 18
gauge SS, form work, scaffolding, all labour, hire and fuel
charges for all tools and plants employed and all other
incidental charges etc. all complete, as directed. ( For both
internal and extrernal walls )

a. Solid block wall of 200 mm thick Sqm 120

b. Solid block wall of 100 mm thick Sqm Qro

7.00 FLOORING AND DADOING WORKS


7.01 Providing flooring with Premium quality Restile / Boss /
RAK / Johnson ceramics or approved equivalent make
vitrified floor tiles (seamless)of basic price not less than 850
/ Sqm confirming to ISO 13006/EN 176 Group BIa with
tech.specification as Mohs scratch hardness greater than
6,Water Absorption of 0.05%, Modulus of Rupture greater
than 45 N/mm, Deep Abrasion resistant less than 150 mm
cube, Surface flatness, Straightness of sides 0.20%,
thickness 5% of size of approved colour and size & thick
as specified below, set in Laticrete adhesive L 290 and
pointing with Laticrete make Latapoxy SP 100 of approved
make, to matching colour shade as per Manufacturer's
Specification and as directed. Rate shall include wastages,
for preparation of base surface, cleaning, acid wash, and
finished surface, protection with Gypsum / Pop layer over
Plastic sheet and removing the same before handing over,
work at all levels and as directed.Rate shall be inclusive of
forming pattern as shown in dwg and wastages etc;
complete.

i Mirror polish of size 400 x 400mm Sqm 45


ii Mirror polish of Size 600 mm x 600 mm / 598 mm x 598 mm
- 8 / 9 mm thick Sqm Qro

C.R.Narayana Rao
Architects &Engineers 171 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

7.02 Providing 100 mm high skirting with Premium quality


Restile / Boss / RAK / Johnson or approved equivalent
make vitrified floor tiles (seamless) confirming to ISO
13006/EN 176 Group BIa with tech.specification as Mohs
scratch hardness greater than 6,Water Absorption of
0.05%, Modulus of Rupture greater than 45 N/mm, Deep
Abrasion resistant less than 150 mm cube, Surface
flatness, Straightness of sides 0.20%, thickness 5% of
size of approved colour and size & thick as specified
below, set in Laticrete adhesive L 290 and pointing with
Laticrete make Latapoxy SP 100 of approved make, to
matching colour shade as per Manufacturer's Specification
and as directed. Rate shall include wastages, for
preparation of base surface, cleaning, acid wash, and
finished surface, protection with Gypsum / Pop layer over
Plastic sheet and removing the same before handing over,
work at all levels and as directed.Rate shall be inclusive of
forming pattern as shown in dwg and wastages etc;
complete.

i Mirror polish of Size 300 mm x 300 mm - 8 / 9mm thick


RM. 40
7.03 Providing and laying glazed ceramic tiles (white / Coloured)
for floor tile & wall tile shall have size of 200 x 200 mm - 7.0
mm thick set in CM 1:4, 20 mm thick and pointing the
joints with Roff Tile filler compound as per Manufacturer's
Specification and as directed. Rate shall include for
preparation of base surface, and finished the surface, Sqm 20
cleaning the surface, and protecting and with Gypsum /
POP layer over Plastic sheet and removing the same
before handing over, work at all levels etc. complete.

7.04 Providing flooring with best quality Kajaria / Nitco / Regency


/ Bell / Johnson or approved equivalent make ceramic tiles
(Anti skid/ Non slippery) ranges as listed below shall have
size of 400 x 400 mm - 7.0mm thick set in CM 1:4, 20 mm
thick and pointing the joints with Roff Tile filler compound
as per Manufacturer's Specification and as directed. Rate
shall include for preparation of base surface, and finished
the surface, cleaning the surface, and protecting and with
Gypsum / POP layer over Plastic sheet and removing the
same before handing over,work at all levels etc. complete
all as directed.

i Group V / V + / IV series Sqm 25

ii. Special Printed series Sqm Qro

iii. Plain series Sqm Qro

C.R.Narayana Rao
Architects &Engineers 172 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

7.05 Providing & laying best quality approved colour granite slab
of any approved colour for counter top not less than 20mm
thick of size not less than 1800mm x 600mm , machine cut
and machine high pre-polished, set in C.M 1:4, 20 mm thick
topped with white cement slurry (for surface contact of the
bottom of the granite slab) as per approved pattern / design
including finishing the joints with white cement slurry,
cutting, edge chamfering and polishing rough, medium, nice Sqm 20
and acid wash and tin-oxide polish as per manufacturer's
Specification and as directed. Rate shall include for
preparation of base surface & finished the surface,
protection with gypsum / pop layer over plastic sheet and
removing the same before handing over, work at all levels
and as directed.

8.00 JOINERY WORKS


8.01 Providing and fixing 32mm thick flush door shutters (Kutty /
Diamond/Jackson's make) single leaf / Double leaf of solid
core of block board type bonded with phenol formaldehyde
synthetic resin thermo pressed with 8 mm thick teak wood
tongue & groove external lipping. The construction
procedure of the shutter should be as per IS 2202. The
shutter shall be shop prepared for taking mortice lock or
latches suitable lock block of wood may be provided for
fixing the hardware. The size of block, shall perfectly
correspond to the maximum size of lock, covered in IS
2209. All the four edges of the door shutter shall be
square. The shutter shall be free from twist or warp in its
plane and of required size etc. complete as directed.

i) Hardwares :
i) Hinge : Providing and fixing Stainless steel satin finish
double ball bearing butt hinges with SS screws of size 100
x 75 x 3 mm thick - Model No. SS 551 B - class 8 / 9 from
Dorma or approved equivalent make suitably for Single /
Double leaf door. Stainless steel conforming to SS 316 L
grade to BS 7352 or BS EN 1935-2002. 4 Nos for Single
Leaf Shutter and 8 Nos for Double Leaf Shutter.

ii) Provision :
i) Provision / fixing arrangements to be made in the shutter
as well as in the frame to receive / fix the Hinges, Locks,
Electro magnetic latch, Electro magnetic contact for hooter
with reinforcement pads and in such a way to connect the
same to the card access control system / IBMS.
ii) Refer hardware schedule enclosed for the details of
Mortise sash lock, Mortise dead lock, Handles, Push plates
and Panic bar etc. Necessary provision shall be made in
the frame and shutter to receive and fix the hardwares.
iii) Supplying Master key for the doors either floor wise or
wing wise as per the Master key plan including supplying
Grand Master key for all the doors.

C.R.Narayana Rao
Architects &Engineers 173 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Note :
1. All the Materials and hardware specifications proposed
for door shall conform to the codes, technical specification
and preamble to the bills of quantities.
2. Quoted rate shall be deemed to have considered all the
items covered in the specification and drawings, whether
explicitly stated or not.

Rate shall include for making provision to fix the approved


hardwares as specified in the tender drawing schedule as a
separate item etc. complete and as directed.
Rate shall include the following

Rate shall include necessary all approved hardwares as


specified in the tender drawings etc. complete and as
directed.

a. Single leaf Flush door. Fully flush shutter with commercial


ply on both sides and finished with 1.5mm thick laminate on
both sides of approved colour, make and shade. Sqm 5

b. Double leaf Flush door - Fully flush shutter with


commercial ply on both sides and finished with 1.5mm thick
laminate on both sides of approved colour, make and Sqm Qro
shade.

8.02 FLUSH DOOR HARDWARES

Extra rate over and above steel door items for providing and
fixing the following Hardwares in position in the doors
supplied with all necessary accessories etc complete and
as directed.

a Mortice Sash lock with lever handle and internal thump


turn - Stainless steel satin finish - 316 L grade of ST 8100 -
lever handle on both sides with ST 7122 WC indicator with
775 lock or approved euivalent make with forend and strike
Each 2
plate of Dorma make and the strike plate shall be provided
to suit the type of door specified. Stainless steel shall
conform to BS.

b Automatic door closer Model No.TS 92 cam action G


(Push/Pullside) or B (Push/Pull side) EN 2 to 4 of Dorma
make. (Door closer shall be provided to suit the type of door
opening / opening policy specified. Ie. Double / Single leaf Each Qro
and Push / pull side) with all other accessories.(To use
Shutter width upto 1100 mm)

c. Extra rate over and above item no a & b for making opening
in Toilet door in all blocks / floors for fixing the Air Transfer
grill

a. 500 x 300 mm Each Qro


b. 300 x 200 mm Each 2

C.R.Narayana Rao
Architects &Engineers 174 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

8.03 Providing and fixing in position frames of any size and


section for Doors, Windows, Ventilators, any openings and
in Jambs, shaped, planed and fixed with necessary jointing
method approved including pins, nails, screws and bolts
etc. Rate shall include for cost of bolts, nuts, screws,
nails, pins, Hot dip galvanised MS approved hold fast and
concrete block grouting for fixing hold fast, anchor fasteners
/ coach screws and including a coat of suitable primer on
the frames to receive the Duco paint finish / Fire Retardant
paint with suitable primer of approved colour etc. complete,
as directed.

a. First class Teakwood confirming to IS specifications and


should be free from any defects and plemishes. Cum Qro

b. First class Padauk wood conforming to IS specifications


and should be free from any defects and plemishes. Cum 0.075

9.00 INTERNAL AND EXTERNAL FINISHES


9.01 Plastering of walls with cement mortar 1:4, 20 mm thick with
a neat floating coat of cement for smooth finish according to
specifications. Rate shall include for providing G.I.chicken
mesh made out of galvanised iron of nominal thickness
0.35 mm with a Zinc coating of 120 gms per Sqm at the
junctions of masonry and concrete works to a width of 100 Sqm 95
to 125mm including tying in position with suitable
clamps/screws,necessary staging,scafolding and curing at
all levels and elevations etc.complete as directed.

9.02 Plastering of R.C walls, peripheral beams and columns with


CM 1:3, 12 mm thick with a neat floating coat of cement for
smooth finish according to the specification. Rate shall
include for providing G.I.chicken mesh made out of
galvanised iron of nominal thickness 0.35 mm with a Zinc
coating of 120 gms per Sqm at the junctions of masonry Sqm 25
and concrete works to a width of 100 to 125mm including
tying in position with suitable clamps/screws,necessary
staging,scafolding and curing at all levels and elevations
etc.complete as directed.

9.03 Plastering of ceiling including slabs, beams and column


drops and staircase waist slabwith CM 1:3, 6 mm thick with
a neat floating coat of cement for smooth finish according to
the specification. The rate shall include necessary Sqm 75
scaffolding, form work and curing etc. complete all as
directed.

9.04 Plastering for external surfaces with base coat of 20 mm


thick in C.M 1:4 with water proofing compound of CICO
No.1 or equivalent as per Manufacturer's Specification and
finishing coat of 10 mm thick in C.M 1:3 after roughening
the surface of first coat in green condition with wire brush
Sqm 125
and clearing of loose particles with sponge finish (washed
sand finish) all complete as per specification and as
directed. Rate shall include for providing drip bands /
moulds / grooves to any size and shape as directed.

C.R.Narayana Rao
Architects &Engineers 175 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

9.05 Providing 15 mm thick water proof plaster in Toilet internal


walls and over head tank with CM 1:3 with water proofing
compound of CICO No:1 or equivalent as per
manufacturers specification and roughening the surface in Sqm. 50
green condition with wire brush and clearing of loose
particles with sponge brush (washed sand finish)

9.06 Applying white washing three coats to ceilings and walls


with pure shell lime or fat lime conforming to IS-712 all as
per Specification and as directed. For shaft , lift interior Sqm 100
walls.
9.07 Providing two coats of first quality water proof cement paint
of approved make and colour over a priming coat of white
colour water proof cement paint or any primer specified by
the manufacturer including preparation of surface by
Sqm Qro
thorough cleaning and wetting before painting and curing all
as per manufacturer`s specifications and as directed.

9.08 Providing two coats of BELCO- Acrylic emulsion paint of


Egg - Shell Finish (Supreme 3 in1of Dulux) to walls of
approved colour over a coat of Dulux Cement Primer
(solvent based) - 34-200 of ICI make, including
preparation of surface by thorough cleaning and free from
grime, dust, grease, loose or flaking particles, if any Sqm 145
haircracks shall be filled, smoothenout the surface by using
ICI Readymix Water Filler (33-500) followed by a coat of
water based cement primer - (32-168) as per
manufacturers specification fully to give an even shade
before painting as directed.
9.09 Providing three coats of 'PLASTIC 'emulsion paint to walls
/ ceiling of approved colour over a coat of water based
primer including preparation of surface by thorough
cleaning and wetting and applying POP/Gypsum powder Sqm 50
putty as per manufacturers specification fully to give an
even shade before painting and curing as per
manufacturers specifications and as directed.

9.10 Supplying and applying "RENOVA" Synthetic plaster over


the prepared plastered surface at three coats. The first coat
of application to be done with Renova ASP by trowel. The
second coat with brush and the final coat should also be
applied with brush. The rate shall include for carrying out Sqm 125
work at all levels, all necessary surface preparation, tools,
scaffolding, taxes etc., all complete. The rate also includes
all colour shades, texture and as pattern per manufactures
shade card.

C.R.Narayana Rao
Architects &Engineers 176 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

9.11 Painting with lustre paint of approved shade and colour of


ICI / Asian Paint or equivalent make, by sand papering the
surface, then applying a coat of primer, then applying two
coat of putti, again sand papering the surface and applying
the coat of paint with roler finish as per Manufacturers Sqm Qro
specification and as directed. Rate shall include for
preparation of surface, scaffolding if any, and cleaning the
surface after applying etc. complete, and as directed.

10.00 WATER PROOFING WORKS

10.01 Water proofing treatment Treatment over RCC roof slab laid
a to slope in terrace and gutter slab covering the following
sequence of operation and specifications:
a) The roof slab laid in slope / gutter slab shall be
thoroughly cleaned by removing the debris and dust, to
receive the water proofing treatment.

0 a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)

c) Applying 2 coats of acrylic polymer modified cement


based, flexible water proofing slurry like TAPECRETE or
approved equivalent make to a thickness of 2mm and cured
for 7 days and as per manufacturer's specification.

d) Supplying, providing and applying water proofing


treatment with Membrane type water proofing methods
using polymer modified Bituminous membrane of CICO
shield/ Build Wrap/ Deboer or approved equivalent make.
The Atactic Poly-Propylene (APP-4mm th)membrane
having UV resistant, ground chemical resistant, high melting
point more than 110 deg. C, flexible and elastic with high
adhesive strength. The membrane shall be reinforced with
non woven polyester reinforcement of minimum of 180
g/sqm and reinforced including coating with compatible
primer of Bituminous base and torch application with
overlap of 100 mm wherever required. The reinforcement
provided shall be able to withstand the traffic flow density
during & after construction and shall carry a minimum
guarantee period of 10 years. Cost to include applying the
primer and torching the entire surface and also
prefabricated overlap at ends. The membrane surface shall
be protected with granules.

C.R.Narayana Rao
Architects &Engineers 177 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

e) Providing, supplying & laying extruded polystyrene rigid


foam panel of size600 x 1200mm-75mm thick of formula
R.Metric-FM 50 having a density of 24 kg/cum and
compressive strength not less than 250 kpa of ownes
corning or approved equivalent make having exeptional
mechanical properties like resistance to the diffusion of
water vapour, resistance to water absorption, uniform
density distribution, dimensional stability, very high
compressive strength, aging resistance and also immunity
against insects, pets, bacteria, rodent attacks and micro
organisms etc., for over deck insulation including necessary
skin shiplap joint,anchores,adhesives, primers etc., as
required for proper fixing etc., complete all as per the
manufacturers specifications & consultants approval. The
extruded polystyrene panel has closed sealed cells
structure linked to one another is produced by a contineous,
fully automated extrusion process in accordance with
international specification and standard etc. all complete.

f) Laying fibre glass cloth over the extruded polystyrene


rigid foam panel.

g) A layer of 20 mm thick cement mortar 1:4 admixed with


CICO NO - 1 (normal setting integral water proofing
compound) or other approved equivalent make compound
shall be spread over the operation specified in point (f)
above and laying brickbat coba over the surface 40mm
thickness at drain point and required thickness at ridge and
the top surface of the brickbat coba shall be plastered with
cement mortar 1:4, 20 mm thick admixed with CICO NO:1
@ 2% by the weight of cement and add RECRON 3S 225
per bag of cement and draw false line of 300 mm X 300 mm
over the finished surface. (The rate shall be quoted for an
average thickness of 110 mm).

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface,dewatering, finishing, curing, scaffolding, supply
and adding water proofing chemicals at the specified
proportion as per manufacturer's specifications, all
materials, wastages, conveyance, tools and plants, mixing Sqm 85
device and gauge, shuttering and also include for
conducting leakage test at terrace by storing water on the
terrace for about 25 mm depth continuously for a period of 7
days etc.complete, as directed.

b Extra rate over and above item, for Providing and laying
brickbat coba using well burnt brick bats set in cement
mortar 1:3 by adding CICO no.1or approved equivalent Cum 10
water proofing compound including curing etc complete as
directed

C.R.Narayana Rao
Architects &Engineers 178 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

11.00 MISCELLANEOUS WORKS


11.01 Providing and laying sand layer in the trenches, drainage
systems or any specified works for full width and alround
the pipes as indicated in the drawing. Cost to include Cum 5
necessary compaction etc., complete.

11.02 Providing and laying 20mm size grade aggregate for any
specified works with the specified width and depth as
indicated in the drawing, cost shall include necessay lead Cum 5
and lift etc., complete.

11.03 Providing and laying in position the RCC humepipes(NP2)


of approved quality and make including collars,.necessary
Excavation, PCC 1:2:4 supports, Sand cushion of 150mm
on all sides, Refilling with earth, Compaction and making
good the level, alignment etc.,complete

a. 450 mm dia Rmt Qro


b, 300 mm dia Rmt Qro
c. 150mm dia Rmt Qro
11.04 Providing and constructing Size stone masonry in CM 1:6
including flush pointing with CM 1:3 after raking out joints,
curing etc. with all necessary bond stones to full width of Cum 5
the wall in every layers and staggered, all complete and as
directed
11.05 Providing and fixing PVC (6 Kg/sqcm class) pipe of
specified dia below and approved make as rain water down
take pipe with all specials, accessories and joints with
solvent cement solution according to manufacturers
specification.

a 110 mm dia Rmt Qro

b 160 mm dia Rmt 15

Total C/o.to Summary of 3 D in Rs..

C.R.Narayana Rao
Architects &Engineers 179 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.00 DRIVER'S REST ROOM

EARTH WORK EXCAVATION


GENERAL NOTES FOR EXCAVATION
Contractor shall take all required permissions from the
appropriate authorities for Excavation, Blasting, Carting
away materials including depositing, levelling etc. and shall
bear all the expenses for the same.
Rate includes removal of all kind of vegetation,small shrubs
etc. Dewatering water to be let out of the building / site area
through proper pipes & channels if required. The contractor
at his own expenses shall water very well, ram and
thoroughly consolidate the bottom of all excavations &
ground before the construction of foundation/footing/plinth
beam, filling in basement floor or other work is
commenced.The rate for excavation shall include for
shoring sides or trenches with approved timber/steel
accessories wherever necessary to prevent sides from
falling including bailing or pumping out of water if necessary
and include If there are any shrubs, bushes, trees, roots of
the trees to be removed for min depth 50. Necessary Lift &
lead for all type of excavated materials to convey them and
to deposit them as directed by the engineer-in-charge are to
be considered.

Contour level to be taken jointly with the engineer-in-charge


and prior written approval to be taken before starting any
excavation/ filling at every 3 / 5 mt grids or at regular
intravels as directed by the engineer -in-charge for arriving
at the actual quantity. Measurements for filling will be taken
for consolidated thickness only.Cost to include all and
necessary royalty and other permission charges required to
execute the works.Unless noted otherwise measurements
shall be considered to the edge of PCC only.

Note: The measurements shall be based on the levels


captured prior and after execution. And in case of stack
measurement, the percentage of 40 % of voids to be
deducted from stack measurement for hard rock (Incase
operated). Blasting shall be carried through licensed
operator having valid blasting licence.

C.R.Narayana Rao
Architects &Engineers 180 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.01 General Excavation by mechanical means in all types of soil


including dense soil, discentegrated/ weathered/ soft rock
for any type of foundation including necessary manual
excavation for dressing the edges & leveling, all leads and
lifts back filling in layers of 150mm with watering and
compaction to the required proctor density . Rate to include
disposing the excess earth and spreading in layers to the
required levels within the site wherever
specified,dewatering of both ground and surface water, Cum 25
removal of slurry generated while excavation and keeping
the area free of water with necessary shoring, struting,
required for keeping earth in position etc,. excavating loose
pockets and compacting the same. Note: Aut
working space and Provision of slopes if required for
execution shall not be paid separately.
Excavation in all types of soils to any depth below ground
level.
3.02 Excavation in Medium rock ( more than 1/2 Cum in size -Un-
poclainable) to the required level & depth (Mass
excavation) including all leads and lifts, stacking excavated
material within plot at approved location , if required de-
watering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
of water with necessary shoring, strutting, stepping, Cum 25
dressing, grading required for keeping earth in position etc.
as per detailed specificationand conforming to safety rules
during progress of the work. Note:Authorised working
space and Provision of slopes if required for execution
shall not be paid separately.

3.03 Same as item No - 1.01 but for general excavation in Hard


rock/ boulders (more than 1/2 Cum in size -Un-poclainable)
by chiselling/ wedging to the required level & depth (Mass
excavation) including all leads and lifts, stacking excavated
material within plot at approved location , if required de-
watering of both ground and surface water, removal of
slurry generated while excavation and keeping the area free
of water with necessary shoring, strutting, stepping, Cum 125
dressing, grading required for keeping earth in position etc.
as per detailed specificationand conforming to safety rules
during progress of the work. Note:Authorised working
space and Provision of slopes if required for execution
shall not be paid separately.

C.R.Narayana Rao
Architects &Engineers 181 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.04 Excavation in hard rock / boulders (more than 1/2Cum in


size) by Controlled Blasting using explosives and trimming
to required level for foundation, trenches, rafts, plinths,
leveling area etc. to the required depth at all leads including
stacking excavated material within plot at approved
location, if required bailing /pumping out of water to keep
site dry at all times until completion of work; shoring, Cum 125
strutting, stepping, dressing, grading, cleaning, removing
and excavating loose pockets as directed etc. all complete
as detailed in specification and conforming to safety rules of
authority from time to time and Explosives rules1940 or as
amended.

3.05 Carting away surplus earth/excavated material/debris and


like materials outside the plot not covered under above
items 1.01 to 1.04 all above items and disposing off the
same to the designated areas to the lead around 10 KM
Cum 300
identified by the local authorities/engineer-in-charge for
dumping of such material,including spreading,compacting
etc.,as per the norms by the local authorities.

3.06 Supply and filling in foundations and the area wherever


specified with approved good quality filling materials in
plinths, sides of retaining wall alround the building ( i.e
backfilling ) area development etc. wherever specified in
layers of not exceeding 150 mm thick including breaking
clods,storing,transportation ,double handling, watering,
compacting each layer with vibratory compactor and at
unaccessible places with wooden/steel rammers to achieve
90 to 95% proctor density at optimum moisture content, all
leads and lifts, bailing/ pumping out of water to keep site dry
while backfilling; cost shall include conveyance of all
materials, labour, machinery etc. complete as directed.The
rate to include loading,unloading, hire and fuel charges for
tools and plants and other incidental charges etc., complete
as directed.

a With approved quality murrum brought from outside. Cum 5


b Approved quality river sand brought from outside Cum 5
c With approved quality quarrydust brought from outside Cum 5
3.07 Providing and laying in position 150mm thick soling with
approved Base preparation by Mechanical compaction,
using hard granite stones / Rubble and smaller pebbles for
void filling, moorum for binding as directed by the Engineer-
in-charge including watering,packing, compaction etc., with Sqm 5
required tools and plants and all lead,lift, conveyance as
required etc., complete as directed.

C.R.Narayana Rao
Architects &Engineers 182 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

3.08 ANTI-TERMITE TREATMENT WORKS


Providing Anti termite treatment in accordance with
stipulations laid down by IS 6313 - part II by approved
agency with min of 10 years of guarantee including the cost
of chemical,precautionary measures etc.complete along
retaining walls only for a width of one meter or as specified
by consultants (treatment for floor is not required and
Sqm 25
agency shall be approved by engineer-in-charge
Note: External periphery length of the retaining wall
multiplied by 1 M will be considered as the measurement
area.

4.00 PLAIN & REINFORCED CEMENT CONCRETE WORKS


4.01 Providing and laying plain cement concrete 1:4:8 using
coarse graded aggregate of 40 mm and down size for
levelling course under footings, steps, walls, platform etc. Cum 2
including form work wherever necessary and well
compacted etc. all complete, as directed.

4.02 Providing and laying P.C.C. 1:3:6 of specified thick


wherever specified using river sand, 20mm and downsize
metal including base reperation, Compaction, levelling, all Cum 65
leads and lifts, curing and shuttering if necessary etc.,
Complete
4.03 Providing and laying P.C.C. 1:2:4 of specified thickness
wherever specified using river sand, 20mm and downsize
aggregate including cleaning,subgrade preparation,
Compaction, levelling, all leads and lifts, rough finishing at
the top surface,curing and shuttering if necessary etc.,at all
heights and depths as instructed.

a DPC, Copings, Flagging concrete, shaft screed etc., Cum 2

READY MIX CONCRETE / CONTROLLED CONCRETE


NOTE: RMC SHALL BE PROCURED FROM SITE
BATCHING PLANT HOWEVER, IN CASE OF READY MIX
CONCRETE PROCURED FROM RMC PLANT THE
PROBABLE CONCRETE CAN BE FETCHED FROM (L&T/
IJM / Redimix).
Providing, batching, mixing, transporting through transit
mixers, pumping and laying controlled Reinforced Cement
Concrete of specified grade at all levels and heights
specified below using ordinary Portland cement of grade 53
from approved manufacturer, river sand, 20mm and down
size coarse aggregates, necessary Mineral admixtures
approved by Consultants (elkem and Conplast SP 430SRV
from Fosroc or equivalent), including all leads and lifts,
pumping using line pump or boom placer, vibrating/
compaction, scaffolding wherever necessary, curing as
directed, excluding cost of shuttering and reinforcement
works.

(Design mix shall be as approved by the Structural


Consultant / Employer's representatives

C.R.Narayana Rao
Architects &Engineers 183 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.04 M30 Grade


Columns at

Ground floor Cum 20


First Floor Cum 20
Terrace Floor Cum 5
Flat slabs at all levels
First Floor Cum 70
Terrace Floor Cum 70
Above terrace Cum 5

Beams at all levels

First Floor Cum 25


Terrace Floor Cum 25
Above terrace Cum 5
M30 GRADE CONCRETE
4.05 RCC Parapet at all levels of specified thickness Cum 10
4.06 Footings/ Rafts for columns,Core walls/ Retaining walls
etc., Cum 100

4.07 Plinth Beam Cum 20


4.08 Grade slab Cum 60
4.09 Staircase at all floors & heights Cum 10
4.10 Lintels at all levels Cum 5
4.11 RCC Brackets/Fins/Ledges/lofts at all levels Cum 5
4.12 Pedestals , foundations for Equipments Cum 5
4.13 U.G.Sump
a Bottom slab Cum Qro
b Walls Cum Qro
c Top slab Cum Qro
4.14 Domestic and Fire fighting Overhead Tank
a Bottom slab Cum 3
b Walls Cum 5
c Top slab Cum 3
4.15 Supplying, drilling and fixing MS anchor rod of 16 mm dia
into the hard rock for 200 mm below footing and 200 mm
anchoring into the footing.Rate shall include for material for Nos Qro
Cement grouting and labour etc, complete

4.16 M25 Grade Concrete


a. RCC Parapet at all levels of specified thickness Cum Qro
b Lintels at all levels Cum Qro
c RCC Brackets/Fins/Ledges at all levels
Cum Qro
d Cill concrete/Fins /Chejjas/Lofts at all levels
Cum Qro

C.R.Narayana Rao
Architects &Engineers 184 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

4.17 M20 Grade Concrete


a. RCC Parapet at all levels of specified thickness Cum Qro
b Lintels at all levels Cum Qro
c RCC Brackets/Fins/Ledges at all levels Cum Qro
d Cill concrete/Fins /Chejjas/Lofts at all levels Cum Qro

5.00 FORM WORK


5.01 Providing, fabricating and erecting form work at all levels
and places wherever needed/specified as per drawing
including striking with 12mm Plastic coated, marine
resistant waterproof ply/Smooth finished MS plates with
adjustable steel props of acceptable Staging system and
with sufficient bracing as approved by consultant. Cost to
include designing of proper form work and staging system
to suit the requirements,Submission of design calculations
and shop drawings for approval,sealing the joints with
heavy duty brown self adhesive tape, aligning to line and
levels including M.S. Ties, PVC Spacer, Providing
openings/ cutouts/ pockets, applying deshuttering chemical,
Deshuttering as approved by the consultant etc., complete
at all levels, double/tripple heights and profiles for Note :
Only plan area shall be considered.No extra shall be paid
for Side shuttering of Drop panel/column capitals.

1) plywood shuttering shall be considered for all vertical


elements, beam soffit, corewalls, stairs, ramps, tanks,
RCCpedestals Etc.,
2) M.S. plates shall be considered for foundation,slabs
only.
3) Shuttering & deshuttering sequence shall be 100%, 80%
& 40% from the slab to be cast respectively
a Columns at
Ground floor Sqm 185
First Floor Sqm 160
Terrace Floor Sqm 30
b Flat slabs at all levels
First Floor Sqm 265
Terrace Floor Sqm 265
Above terrace Sqm 15
c Beams at all levels
First Floor Sqm 210
Terrace Floor Sqm 210
Above terrace Sqm 55

5.02 RCC Parapet at all levels of specified thickness Sqm 100


5.03 Footings/ Rafts for columns,Core walls/ Retaining walls
Sqm 200
etc.,
5.04 Plinth Beam Sqm 130
5.05 Grade slab Sqm 20
5.06 Staircase at all floors & heights Sqm 70
5.07 Lintels at all levels Sqm 50
5.08 RCC Brackets/Fins/Ledges at all levels Sqm 50

C.R.Narayana Rao
Architects &Engineers 185 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

5.09 Pedestals , foundations for Equipments Sqm 15


5.10 U.G.Sump
a Bottom slab Sqm Qro
b Walls Sqm Qro
c Top slab Sqm Qro
5.11 Domestic and Fire fighting Overhead Tank
a Bottom slab Sqm 8
b Walls Sqm 30
c Top slab Sqm 8
5.12 Providing, fixing reinforced cement concrete precast slab
with controlled cement concrete - M20 grade using coarse
graded aggregate 20 mm and downsize. Rate shall include
for providing necessary casting platform, shuttering,
finishing the exposed faces smooth wherever necessary
and pointing the joints with C.M 1:3, 15 mm thick curing
and fixing in position etc complete and as directed. Rate
shall include for fixing MS angles of required size based on
the thickness of precast slab and to be fixed on the edges
of the precast slab including grouting the lugs with Cement
concrete 1:1.5:3, GI Hooks for lifting the slab etc complete,
as directed. Necessary reinforcement MS angles,MS
lugs,GI hooks will be paid seperately in the respective
items.

a. 200 mm thick Sqm 2


b. 150 mm thick Sqm 2
c. 125 mm thick Sqm 2
d. 100 mm thick Sqm 2
e. 75 mm thick Sqm 2
f. 50 mm thick Sqm 2
5.13 Providing and fixing precast reinforced cement concrete jalli
work, with controlled cement concrete - M - 20 grade using
coarse graded aggregate of 6 mm and downsize as per
drawing including fixing in position with cement mortar 1:3.
Rate shall include for cost of form work wherever required
and cost of nominal reinforcement with 8mm dia.-Fe 415
steel at required spacing confirming to IS standards and
specification etc complete and as directed.

a. 100 mm thick Sqm 5

C.R.Narayana Rao
Architects &Engineers 186 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

6.00 IRON & STEEL WORKS


6.01 Providing and fixing reinforcement for RCC work with
Thermo mechanically treated (TMT) bar of various
diameters and grade of steel as specified below conforming
to IS or equivalent BS specification including cutting and
waste, bending, hoisting, fabricating and placing in position
according to drawings and binding the reinforcement with
galvanised annealed binding wire of double fold of 18
gauge and providing PVC cover blocks for placing the
reinforcements in position and for maintaining the cover
specified and/or according to relevant IS or equivalent BS
code.

Note : Unless noted otherwise the measurements in


accordance with IS 1200 or equivalent BS. However
reinforcement shall be measured only in lengths of bars as
actually placed in position on standard weight basis, no
allowance being made in the weight for rolling margin.
Authorised laps and splices, Chairs of any shape & profile,
Spacer bar of any shape & profile, cover block, wastage
and binding wire will not be measured and shall be included
in the quoted rates.Quoted rate shall be deemed to have
considered the above stipulation.Quoted rate to include
lead, lift, placing at all levels and as directed. Detailing of
the reinforcement shall be ductile detailing for seismic
zone III as per codal requirement.

I Grade of reinforced steel - Fe 500 MT 48

7.00 MASONRY WORKS


7.01 Providing and constructing brick work with best quality
well chamber table moulded bricks with minimum
compressive strength of 50 Kg per Sqcm in cement mortar Cum 5
1:5 in foundation and basements, etc. complete, all as
directed.

7.02 Providing and constructing brick work with best quality well
chamber table moulded bricks with minimum compressive
strength of 50 Kg per Sqcm. in cement mortar 1:5 in Cum 5
superstructure at all levels etc. complete, all as directed.

C.R.Narayana Rao
Architects &Engineers 187 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

7.03 Providing and constructing 115 mm thick masonry wall at all


levels with approved best quality well chamber burnt
moulded bricks with minimum compressive strength of 50
Kg/Sq.cm in cement mortar 1:4 with M20 reinforced cement
concrete binders - 80 mm thick laid horizontally to the full
length of the wall at 1000 mm ctc using coarse graded
aggregate of 12 mm and downsize and reinforced with 8
mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm dia for
Sqm 200
stirrups at 200mm centres using Fe 500 grade steel. Rate
shall include for cost of reinforcements and tying in postion
using binding wire made out of 16 gauge GI annealed or 18
gauge SS, form work, scaffolding, raking out joints, curing
etc complete and as directed.

7.04 Providing and constructing cement concrete solid block


masonry work at all levels in cement mortar 1:3 using
standard size of 400 x 200 mm of solid cement concrete
blocks of thickness as specified below having compressive
strength of 5.5 N/ sqmm including all scaffolding, staging,
curing, all lifts etc. complete and as directed as per the IS
relevant standards. Concrete blocks manufactured under
strict quality control conditions using modern rugged block
casting and stripping machine with the latest moulding
techniques etc. only shall be used.

a. 200 mm thick wall Sqm 650

b. 150 mm thick wall Sqm 50


7.05 Extra rate over & above Solid / Hollow Masonry wall for
providing R.C.Binders of 80 mm thick laid horizontally to
the full length of the wall at 1000 mm ctc using coarse
graded aggregate of 12 mm and downsize and reinforced
with 8 mm dia. 3 Nos.at bottom & 2 Nos at top and 8mm
dia for stirrups at 200mm centres using Fe-500 grade steel,
including cost of reinforcements and tying in postion using
binding wire made out of 16 gauge GI annealed or 18
gauge SS, form work, scaffolding, all labour, hire and fuel
charges for all tools and plants employed and all other
incidental charges etc. all complete, as directed. ( For both
internal and extrernal walls )

a. Solid block wall of 200 mm thick Sqm 650

b. Solid block wall of 100 mm thick Sqm 50

C.R.Narayana Rao
Architects &Engineers 188 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

8.00 FLOORING AND DADOING WORKS


8.01 Providing flooring with Premium quality Restile / Boss /
RAK / Johnson ceramics or approved equivalent make
vitrified floor tiles (seamless)of basic price not less than 850
/ Sqm confirming to ISO 13006/EN 176 Group BIa with
tech.specification as Mohs scratch hardness greater than
6,Water Absorption of 0.05%, Modulus of Rupture greater
than 45 N/mm, Deep Abrasion resistant less than 150 mm
cube, Surface flatness, Straightness of sides 0.20%,
thickness 5% of size of approved colour and size & thick
as specified below, set in Laticrete adhesive L 290 and
pointing with Laticrete make Latapoxy SP 100 of approved
make, to matching colour shade as per Manufacturer's
Specification and as directed. Rate shall include wastages,
for preparation of base surface, cleaning, acid wash, and
finished surface, protection with Gypsum / Pop layer over
Plastic sheet and removing the same before handing over,
work at all levels and as directed.Rate shall be inclusive of
forming pattern as shown in dwg and wastages etc;
complete.

i Mirror polish of size 400 x 400mm Sqm 400


ii Mirror polish of Size 600 mm x 600 mm / 598 mm x 598 mm
- 8 / 9 mm thick Sqm Qro

8.02 Providing 100 mm high skirting with Premium quality


Restile / Boss / RAK / Johnson or approved equivalent
make vitrified floor tiles (seamless) confirming to ISO
13006/EN 176 Group BIa with tech.specification as Mohs
scratch hardness greater than 6,Water Absorption of
0.05%, Modulus of Rupture greater than 45 N/mm, Deep
Abrasion resistant less than 150 mm cube, Surface
flatness, Straightness of sides 0.20%, thickness 5% of
size of approved colour and size & thick as specified
below, set in Laticrete adhesive L 290 and pointing with
Laticrete make Latapoxy SP 100 of approved make, to
matching colour shade as per Manufacturer's Specification
and as directed. Rate shall include wastages, for
preparation of base surface, cleaning, acid wash, and
finished surface, protection with Gypsum / Pop layer over
Plastic sheet and removing the same before handing over,
work at all levels and as directed.Rate shall be inclusive of
forming pattern as shown in dwg and wastages etc;
complete.
i Mirror polish of Size 300 mm x 300 mm - 8 / 9mm thick
RM. 125
8.03 Providing and laying glazed ceramic tiles (white / Coloured)
for floor tile & wall tile shall have size of 200 x 200 mm - 7.0
mm thick set in CM 1:4, 20 mm thick and pointing the
joints with Roff Tile filler compound as per Manufacturer's
Specification and as directed. Rate shall include for
Sqm 165
preparation of base surface, and finished the surface,
cleaning the surface, and protecting and with Gypsum /
POP layer over Plastic sheet and removing the same
before handing over, work at all levels etc. complete.

C.R.Narayana Rao
Architects &Engineers 189 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

8.04 Providing flooring with best quality Kajaria / Nitco / Regency


/ Bell / Johnson or approved equivalent make ceramic tiles
(Anti skid/ Non slippery) ranges as listed below shall have
size of 400 x 400 mm - 7.0mm thick set in CM 1:4, 20 mm
thick and pointing the joints with Roff Tile filler compound
as per Manufacturer's Specification and as directed. Rate
shall include for preparation of base surface, and finished
the surface, cleaning the surface, and protecting and with
Gypsum / POP layer over Plastic sheet and removing the
same before handing over,work at all levels etc. complete
all as directed.

i Group V / V + / IV series Sqm 350

ii. Special Printed series Sqm Qro

iii. Plain series Sqm Qro


8.05 Providing & laying best quality approved colour granite slab
of any approved colour for counter top not less than 20mm
thick of size not less than 1800mm x 600mm , machine cut
and machine high pre-polished, set in C.M 1:4, 20 mm thick
topped with white cement slurry (for surface contact of the
bottom of the granite slab) as per approved pattern / design
including finishing the joints with white cement slurry,
cutting, edge chamfering and polishing rough, medium, nice Sqm 25
and acid wash and tin-oxide polish as per manufacturer's
Specification and as directed. Rate shall include for
preparation of base surface & finished the surface,
protection with gypsum / pop layer over plastic sheet and
removing the same before handing over, work at all levels
and as directed.

8.06 Providing flooring with best quality approved Kotah stone


slab not less than 30 mm thick and the size of slab in
general not less than 1800 x 600mm, machine cut and
machine high pre-polished, set in C.M 1:4, 20 mm thick
topped with white cement slurry (for surface contact of the
bottom of the granite slab) as per approved pattern/design
by using irrespective of size and shape, including finishing
the joints with white cement slurry, cutting, edge chamfering Sqm 25
and polishing rough, medium, nice and acid wash and tin-
oxide polish as per manufacturer's Specification and as
directed.Rate shall include for preparation of base surface
& finished the surface, protection with gypsum/pop layer
over plastic sheet and removing the same before handing
over,work at all levels, as directed. (For Staircase Landing
Areas)

C.R.Narayana Rao
Architects &Engineers 190 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

8.07 Providing and fixing step risers and treads with approved
Kotah stone slab of thickness not less than 30mm in
single piece for each step patterned as per drawing over
a bed of C.M 1:4, 20 mm thick, all edges machine cut,
machine polished as per manufacturers specification and
as directed. Rate shall include for preparation of base
surface, jointing with matching cement slurry and finished Sqm 35
surface protection with gypsum / POP layer over plastic
sheet and removing the same before handing over, work at
all levels etc complete, all as directed.

8.08 Providing 125 mm high skirting with good quality Kotah


stone slab of thickness not less than 20 mm, with edges
machine cut and exposed faces polished to match the floor
set in cement mortar 1:3 of 12mm thick including chasing of
wall wherever necessary and making good at the junction
with necessary plastering etc. Rate shall include for rough, Rmt 20
medium, nice, acid wash and tin oxide polishing as per
Manufacturers specification and as directed.

9.00 JOINERY WORKS


9.01 Providing and fixing 32mm thick flush door shutters (Kutty /
Diamond/Jackson's make) single leaf / Double leaf of solid
core of block board type bonded with phenol formaldehyde
synthetic resin thermo pressed with 8 mm thick teak wood
tongue & groove external lipping. The construction
procedure of the shutter should be as per IS 2202. The
shutter shall be shop prepared for taking mortice lock or
latches suitable lock block of wood may be provided for
fixing the hardware. The size of block, shall perfectly
correspond to the maximum size of lock, covered in IS
2209. All the four edges of the door shutter shall be
square. The shutter shall be free from twist or warp in its
plane and of required size etc. complete as directed.

i) Hardwares :
i) Hinge : Providing and fixing Stainless steel satin finish
double ball bearing butt hinges with SS screws of size 100
x 75 x 3 mm thick - Model No. SS 551 B - class 8 / 9 from
Dorma or approved equivalent make suitably for Single /
Double leaf door. Stainless steel conforming to SS 316 L
grade to BS 7352 or BS EN 1935-2002. 4 Nos for Single
Leaf Shutter and 8 Nos for Double Leaf Shutter.

C.R.Narayana Rao
Architects &Engineers 191 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

ii) Provision :
i) Provision / fixing arrangements to be made in the shutter
as well as in the frame to receive / fix the Hinges, Locks,
Electro magnetic latch, Electro magnetic contact for hooter
with reinforcement pads and in such a way to connect the
same to the card access control system / IBMS.
ii) Refer hardware schedule enclosed for the details of
Mortise sash lock, Mortise dead lock, Handles, Push plates
and Panic bar etc. Necessary provision shall be made in
the frame and shutter to receive and fix the hardwares.
iii) Supplying Master key for the doors either floor wise or
wing wise as per the Master key plan including supplying
Grand Master key for all the doors.

Note :
1. All the Materials and hardware specifications proposed
for door shall conform to the codes, technical specification
and preamble to the bills of quantities.
2. Quoted rate shall be deemed to have considered all the
items covered in the specification and drawings, whether
explicitly stated or not.

Rate shall include for making provision to fix the approved


hardwares as specified in the tender drawing schedule as a
separate item etc. complete and as directed.
Rate shall include the following

Rate shall include necessary all approved hardwares as


specified in the tender drawings etc. complete and as
directed.

a. Single leaf Flush door. Fully flush shutter with commercial


ply on both sides and finished with 1.5mm thick laminate on
both sides of approved colour, make and shade. Sqm 45

b. Double leaf Flush door - Fully flush shutter with


commercial ply on both sides and finished with 1.5mm thick
laminate on both sides of approved colour, make and Sqm 8
shade.

9.02 FLUSH DOOR HARDWARES

Extra rate over and above steel door items for providing and
fixing the following Hardwares in position in the doors
supplied with all necessary accessories etc complete and
as directed.

a Mortice Sash lock with lever handle and internal thump


turn - Stainless steel satin finish - 316 L grade of ST 8100 -
lever handle on both sides with ST 7122 WC indicator with
775 lock or approved euivalent make with forend and strike
Each 25
plate of Dorma make and the strike plate shall be provided
to suit the type of door specified. Stainless steel shall
conform to BS.

C.R.Narayana Rao
Architects &Engineers 192 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

b Automatic door closer Model No.TS 92 cam action G


(Push/Pullside) or B (Push/Pull side) EN 2 to 4 of Dorma
make. (Door closer shall be provided to suit the type of door
opening / opening policy specified. Ie. Double / Single leaf Each 8
and Push / pull side) with all other accessories.(To use
Shutter width upto 1100 mm)

c. Extra rate over and above item no a & b for making opening
in Toilet door in all blocks / floors for fixing the Air Transfer
grill

a. 500 x 300 mm Each Qro


b. 300 x 200 mm Each 15
9.03 Providing and fixing in position frames of any size and
section for Doors, Windows, Ventilators, any openings and
in Jambs, shaped, planed and fixed with necessary jointing
method approved including pins, nails, screws and bolts
etc. Rate shall include for cost of bolts, nuts, screws,
nails, pins, Hot dip galvanised MS approved hold fast and
concrete block grouting for fixing hold fast, anchor fasteners
/ coach screws and including a coat of suitable primer on
the frames to receive the Duco paint finish / Fire Retardant
paint with suitable primer of approved colour etc. complete,
as directed.

a. First class Teakwood confirming to IS specifications and


should be free from any defects and plemishes. Cum Qro

b. First class Padauk wood conforming to IS specifications


and should be free from any defects and plemishes. Cum 0.85

9.04 Providing and fixing aluminium fixed cum sliding windows


fabricated as per drawing and fixed at all levels, elevations
and heights having a main frame work of vertical and
horizontals, out of specially designed approved extruded
sections to withstand the designed wind pressure and
loads. The extruded section shall be finished with
electrolylic colour anodised of approved colour with anodic
coating not less than 20 microns and the extruded
aluminium sections shall be of 6063 Alloy or BSH9
conforming to IS 63400.

Rate shall include to fix the main frames into masonry wall /
RC concrete surface with necessary clamps, fastening
straps, nuts, bolts, rivets, washers and other fastening
materials shall be in stainless steel or aluminium. Rate
shall include for providing clear toughened glass 5.5 mm
thick and to be fixed with snap fit aluminium beading section
and special water proof EPDM Gasket, Neoprene etc.
complete. Necessary silicon sealant of Dowcorning 795 or
approved equivalent make shall be provided at the
junctions between wall and main frames.

C.R.Narayana Rao
Architects &Engineers 193 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Rate shall include stainless steel safety clips to be provided


on each corner of glass as an additional safety to avoid
breakage of corner of the glass and also to be provided
with EPDM / Neoprene tripple barrier, extruded Reddiprone
weather strip to ensure water and air tightness and shall Sqm 60
include to conduct the performance test conforming to IS
Specification, etc. complete all as directed.

9.05 Providing and fixing of Aluminium grills in outerside of the


Aluminium windows, In Generall 63x37x2mm Aluminium
anodised tubler section at vertically 900 mm c/c horizontally
as directed by Architects or Engineers. Penals are covered
with 8mm thk auminium grills of 37mmx37mm fixing with Sqm 60
aluminium anidised glazing clips with necessary rubber
gascut, etc. The rate shell be inclusive of necessary
hardwares and Aluminium L angle of 3mm thk for
connecting Aluminium frame work.
9.06 Providing and fixing aluminium fixed Ventilators fabricated
as per drawing and fixed at all levels, elevations and
heights having a main frame work of vertical and
horizontals, out of specially designed approved extruded
sections to withstand the designed wind pressure and
loads. The extruded section shall be finished with
electrolylic colour anodised of approved colour with anodic
coating not less than 20 microns and the extruded
aluminium sections shall be of 6063 Alloy or BSH9
conforming to IS 63400.

Rate shall include to fix the main frames into masonry wall /
RC concrete surface with necessary clamps, fastening
straps, nuts, bolts, rivets, washers and other fastening
materials shall be in stainless steel or aluminium. Rate
shall include for providing clear toughened glass 5.5 mm
thick and to be fixed with snap fit aluminium beading section
and special water proof EPDM Gasket, Neoprene etc.
complete. Necessary silicon sealant of Dowcorning 795 or
approved equivalent make shall be provided at the
junctions between wall and main frames.

Rate shall include stainless steel safety clips to be


provided on each corner of glass as an additional
safety to avoid breakage of corner of the glass and also
to be provided with EPDM / Neoprene tripple barrier,
extruded Reddiprone weather strip to ensure water and Sqm 5
air tightness and shall include to conduct the performance
test conforming to IS Specification, etc. complete all as
directed.

C.R.Narayana Rao
Architects &Engineers 194 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

10.00 INTERNAL AND EXTERNAL FINISHES


10.01 Plastering of walls with cement mortar 1:4, 20 mm thick with
a neat floating coat of cement for smooth finish according to
specifications. Rate shall include for providing G.I.chicken
mesh made out of galvanised iron of nominal thickness
0.35 mm with a Zinc coating of 120 gms per Sqm at the
junctions of masonry and concrete works to a width of 100 Sqm 1250
to 125mm including tying in position with suitable
clamps/screws,necessary staging,scafolding and curing at
all levels and elevations etc.complete as directed.

10.02 Plastering of R.C walls, peripheral beams and columns with


CM 1:3, 12 mm thick with a neat floating coat of cement for
smooth finish according to the specification. Rate shall
include for providing G.I.chicken mesh made out of
galvanised iron of nominal thickness 0.35 mm with a Zinc
coating of 120 gms per Sqm at the junctions of masonry Sqm 150
and concrete works to a width of 100 to 125mm including
tying in position with suitable clamps/screws,necessary
staging,scafolding and curing at all levels and elevations
etc.complete as directed.

10.03 Plastering of ceiling including slabs, beams and column


drops and staircase waist slabwith CM 1:3, 6 mm thick with
a neat floating coat of cement for smooth finish according to
the specification. The rate shall include necessary Sqm 575
scaffolding, form work and curing etc. complete all as
directed.

10.04 Plastering for external surfaces with base coat of 20 mm


thick in C.M 1:4 with water proofing compound of CICO
No.1 or equivalent as per Manufacturer's Specification and
finishing coat of 10 mm thick in C.M 1:3 after roughening
the surface of first coat in green condition with wire brush
and clearing of loose particles with sponge finish (washed Sqm 650
sand finish) all complete as per specification and as
directed. Rate shall include for providing drip bands /
moulds / grooves to any size and shape as directed.

10.05 Providing 15 mm thick water proof plaster in Toilet internal


walls and over head tank with CM 1:3 with water proofing
compound of CICO No:1 or equivalent as per
manufacturers specification and roughening the surface in Sqm. 350
green condition with wire brush and clearing of loose
particles with sponge brush (washed sand finish)

10.06 Applying white washing three coats to ceilings and walls


with pure shell lime or fat lime conforming to IS-712 all as
per Specification and as directed. For shaft , lift interior Sqm 725
walls.

C.R.Narayana Rao
Architects &Engineers 195 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

10.07 Providing two coats of first quality water proof cement paint
of approved make and colour over a priming coat of white
colour water proof cement paint or any primer specified by
the manufacturer including preparation of surface by
Sqm 50
thorough cleaning and wetting before painting and curing all
as per manufacturer`s specifications and as directed.

10.08 Providing two coats of BELCO- Acrylic emulsion paint of


Egg - Shell Finish (Supreme 3 in1of Dulux) to walls of
approved colour over a coat of Dulux Cement Primer
(solvent based) - 34-200 of ICI make, including
preparation of surface by thorough cleaning and free from
grime, dust, grease, loose or flaking particles, if any Sqm 1600
haircracks shall be filled, smoothenout the surface by using
ICI Readymix Water Filler (33-500) followed by a coat of
water based cement primer - (32-168) as per
manufacturers specification fully to give an even shade
before painting as directed.
10.09 Providing three coats of 'PLASTIC 'emulsion paint to walls
/ ceiling of approved colour over a coat of water based
primer including preparation of surface by thorough
cleaning and wetting and applying POP/Gypsum powder Sqm 50
putty as per manufacturers specification fully to give an
even shade before painting and curing as per
manufacturers specifications and as directed.

10.10 Supplying and applying "RENOVA" Synthetic plaster over


the prepared plastered surface at three coats. The first coat
of application to be done with Renova ASP by trowel. The
second coat with brush and the final coat should also be
applied with brush. The rate shall include for carrying out Sqm 650
work at all levels, all necessary surface preparation, tools,
scaffolding, taxes etc., all complete. The rate also includes
all colour shades, texture and as pattern per manufactures
shade card.

C.R.Narayana Rao
Architects &Engineers 196 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

11.00 WATER PROOFING WORKS


NOTE: Specialized agency to be approved by Client /
Consultants. PRINCIPAL MANUFACTURER SHALL GIVE
GUARANTEE FOR STIPULATED TIME FOR THE
WATERPROOFING WORKS DONE AT SITE. All surfaces
to be waterproofed should be sound, clean and dry.
Concrete surfaces should have a light steel-trowel followed
by a fine hair-broom or equivalent finish, which is dry and
free of dust, oil and other contaminants. All high spots
should be removed. Moss and lichen must be removed
physically followed by treatment with fungicidal wash to kill
any spores and inhibit further growth. After treatment wash
down thoroughly with clean water and allow to dry. Grouting
periphery of spout pipes with water insensitive epoxy,
pressure grouting of construction joints and honey comb
areas with cement grout, proper preparation of the concrete
surface by mechanical means/hydro blasting to ensure a
good bond between the topping and the substrate,Testing
of the surfaces prior to start the work,after completion and
after a period of one month after completion by
ponding,grouting or sealing of joints,making vatta at corners/j
rates Contractor shall give both material and preformance gu
the approved format.
11.01 Treatment on Toilet floor slab, junctions of floor slab & wall
and side walls in toilets internal surfaces etc. covering the
following sequence of operation:

a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)

b) Providing, supplying, mixing, applying two coats of ready


to use two component Acrylic polymer modified cement
based, flexible, water proofing slurry like TAPECRETE or
approved equivalent to a thickness of 2 mm over the
plastered surface of operation above.

c) Providing, supplying, mixing, laying cement plaster 15


mm thick with cement mortar 1:4 mixed with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth below finished floor level.

C.R.Narayana Rao
Architects &Engineers 197 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 40
plants, mixing device and gauge, shuttering, etc. complete
as per manufacturer's specification and as directed.

11.02 Supplying and filling for sunken slab area with brickbat coba
using half bricks/ full bricks as per specification by adding
CICO NO:1 or approved equivalent admixture at the
specified in the manufacture's specification after entire
completion of laying pipes, sanitary fittings etc. Rate shall Cum 20
include for preparation of surface, protecting the laid pipes
and sanitary fittings, finishing the surface smooth to receive
the top coat of water proofing application etc. complete and
all as directed.

11.03 Treatment to top of brickbat coba in sunken slab covering


the following sequence of operations :
a) Providing and applying water repellant nano technology
coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)
b) Providing, supplying, mixing, applying 2 coats of ready to
use 2 component acrylic polymer modified cement based,
flexible, water proofing slurry like TAPECRETE or approved
equivalent to a thickness of 2 mm over the plastered
surface of operation (a) above including preparation of
surface, dewatering, finishing, curing etc. all complete as
per manufacturer's specification and as directed.

c) Providing, supplying, mixing, laying cement plaster 15


mm thick with cement mortar 1:4 mixed with water proofing
compound like CICO NO:1 (normal setting integral water
proofing compound) or approved equivalent conforming to
IS at the rate specified by the manufacturer over PCC
levelling course at any depth below finished floor level.

Rate shall include for preparation of surface by mechanical


upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface, dewatering, finishing, curing, scaffolding,
waterproofing chemicals, wastage, conveyance, tools and Sqm 40
plants, mixing device and gauge, shuttering, etc. complete
as per manufacturer's specification and as directed.

C.R.Narayana Rao
Architects &Engineers 198 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

11.04 Water proofing treatment over RCC roof slab laid to slope in
a terrace and gutter slab covering the following sequence of
operation and specifications:
a) The roof slab laid in slope / gutter slab shall be
thoroughly cleaned by removing the debris and dust, to
receive the water proofing treatment.

a) Providing and applying water repellant nano technology


coating system over well prepared dry surface covering the
surface area of 30 sqm per litre by mixing ratio of the
component with water in 1:10 by volume ie (one litre of
ZYCOSIL of ZYDEX make or approved equivalent and 10
litres of water)

b) Applying 2 coats of acrylic polymer modified cement


based, flexible water proofing slurry like TAPECRETE or
approved equivalent make to a thickness of 2mm and cured
for 7 days and as per manufacturer's specification.

c) Supplying, providing and applying water proofing


treatment with Membrane type water proofing methods
using polymer modified Bituminous membrane of CICO
shield/ Build Wrap/ Deboer or approved equivalent make.
The Atactic Poly-Propylene (APP-4mm th)membrane
having UV resistant, ground chemical resistant, high melting
point more than 110 deg. C, flexible and elastic with high
adhesive strength. The membrane shall be reinforced with
non woven polyester reinforcement of minimum of 180
g/sqm and reinforced including coating with compatible
primer of Bituminous base and torch application with
overlap of 100 mm wherever required. The reinforcement
provided shall be able to withstand the traffic flow density
during & after construction and shall carry a minimum
guarantee period of 10 years. Cost to include applying the
primer and torching the entire surface and also
prefabricated overlap at ends. The membrane surface shall
d) Providing, supplying & laying extruded polystyrene rigid
foam panel of size600 x 1200mm-75mm thick of formula
R.Metric-FM 50 having a density of 24 kg/cum and
compressive strength not less than 250 kpa of ownes
corning or approved equivalent make having exeptional
mechanical properties like resistance to the diffusion of
water vapour, resistance to water absorption, uniform
density distribution, dimensional stability, very high
compressive strength, aging resistance and also immunity
against insects, pets, bacteria, rodent attacks and micro
organisms etc., for over deck insulation including necessary
skin shiplap joint,anchores,adhesives, primers etc., as
required for proper fixing etc., complete all as per the
manufacturers specifications & consultants approval. The
extruded polystyrene panel has closed sealed cells
structure linked to one another is produced by a contineous,
fully automated extrusion process in accordance with
international specification and standard etc. all complete.

C.R.Narayana Rao
Architects &Engineers 199 Part - II - Bill of Quantities
Tidel, Coimbatore

S.No Description Unit Qty Rate Amount

f) Laying fibre glass cloth over the extruded polystyrene


rigid foam panel.

g) A layer of 20 mm thick cement mortar 1:4 admixed with


CICO NO - 1 (normal setting integral water proofing
compound) or other approved equivalent make compound
shall be spread over the operation specified in point (f)
above and laying brickbat coba over the surface 40mm
thickness at drain point and required thickness at ridge and
the top surface of the brickbat coba shall be plastered with
cement mortar 1:4, 20 mm thick admixed with CICO NO:1
@ 2% by the weight of cement and add RECRON 3S 225
per bag of cement and draw false line of 300 mm X 300 mm
over the finished surface. (The rate shall be quoted for an
average thickness of 110 mm)
Rate shall include for preparation of surface by mechanical
upgrading to remove all loose mortar and laitance, oil,
grease etc. and washing the surface with water to get neat
surface,dewatering, finishing, curing, scaffolding, supply
and adding water proofing chemicals at the specified
proportion as per manufacturer's specifications, all
materials, wastages, conveyance, tools and plants, mixing Sqm 290
device and gauge, shuttering and also include for
conducting leakage test at terrace by storing water on the
terrace for about 25 mm depth continuously for a period of 7
days etc.complete, as directed.

b Extra rate over and above item, for Providing and laying
brickbat coba using well burnt brick bats set in cement
mortar 1:3 by adding CICO no.1or approved equivalent Cum 30
water proofing compound including curing etc complete as
directed

Total C/o.to Summary of 3 D in Rs.

12.00 MISCELLANEOUS WORKS


12.01 Providing and laying sand layer in the trenches, drainage
systems or any specified works for full width and alround
the pipes as indicated in the drawing. Cost to include Cum 5
necessary compaction etc., complete.
12.02 Providing and laying 20mm size grade aggregate for any
specified works with the specified width and depth as
indicated in the drawing, cost shall include necessay lead Cum 5
and lift etc., complete.
12.03 Providing and laying in position the RCC humepipes(NP2)
of approved quality and make including collars,.necessary
Excavation, PCC 1:2:4 supports, Sand cushion of 150mm
on all sides, Refilling with earth, Compaction and making
good the level, alignment etc.,complete

a 450 mm dia Rmt 2


b 300 mm dia Rmt 3
c. 150mm dia Rmt 5

Total C/o.to Summary of 3 D in Rs.

C.R.Narayana Rao
Architects &Engineers 200 Part - II - Bill of Quantities
Tidel,Coimbatore

TIDEL PARK COIMBATORE LTD


( A JV OF TIDCO, ELCOT, TIDEL & STPI )
BUILDING COMPLEX OF INFORMATION TECHNOLOGY PARK AT VILANKURICHI
(SEZ AREA), COIMBATORE

SEZ Cost Break up format (for reference only)

Note: Tenderer to take copy of this document and sign with their seal and submit along with tender document for token of acceptance. This will form part of the contract
document.

A list of materials given below in the chart shall be treated only as indicative for the contractors. The custom duty/excise duty, VAT or any other tax component for which
exemption are available under SEZ Project and as well as for other materials may be provided.

They should also indicate the labour charges and service tax and cess exemptions available to TIDEL Park Coimbatore Limited.

The bidders may add any more items to the above list as appropriate and indicate the tax components for which TIDEL will get exemptions benefits.

LIST OF BASIC PRICES OF MATERIALS WITH SOURCES

Amount (Rs.)
SUPPLY
Total Material Cost
Entry tax- VAT-1, 2 as SEZ Project
CD/CVD ED ST/CST Total for
Materials Cost 1& 2 &3
Other Supply (C) =
Qty (B)
S.No Description Unit taxes/ (B) + [sum of
(A) (Unit Cost) in Rs.
duties (vi) taxes (i)
(i) (ii) (iii) (iv) (v) (A x B) in Rs.
though (vi)]
(including Basic cost,
transportation, handling and
Insurance Charges, etc.)
(Fill taxes applicable for the item)

A CIVIL WORKS

1 Sand
Cum

C.R.Narayana Rao
Architects &Engineers 201 201-209.xls
Tidel,Coimbatore

Amount (Rs.)
SUPPLY
Total Material Cost
Entry tax- VAT-1, 2 as SEZ Project
CD/CVD ED ST/CST Total for
Materials Cost 1& 2 &3
Other Supply (C) =
Qty (B)
S.No Description Unit taxes/ (B) + [sum of
(A) (Unit Cost) in Rs.
duties (vi) taxes (i)
(i) (ii) (iii) (iv) (v) (A x B) in Rs.
though (vi)]
(including Basic cost,
transportation, handling and
Insurance Charges, etc.)
(Fill taxes applicable for the item)

2 Gravel
Cum

3 Quarry Dust
Cum
Coarse aggregate
4 (Machine crushed)
a 40 mm size aggregate
Cum
b 25 mm size aggregate
Cum
c 20 mm size aggregate
Cum
d 12 mm size chips
Cum
e 10 mm size chips
Cum
4 Cement (Bench mark
rate) 3500
MT
5 Thermo Mechanically
Treated Bars (TMT)
(Bench mark rate)

a) 08 mm Fe415 MT

C.R.Narayana Rao
Architects &Engineers 202 201-209.xls
Tidel,Coimbatore

Amount (Rs.)
SUPPLY
Total Material Cost
Entry tax- VAT-1, 2 as SEZ Project
CD/CVD ED ST/CST Total for
Materials Cost 1& 2 &3
Other Supply (C) =
Qty (B)
S.No Description Unit taxes/ (B) + [sum of
(A) (Unit Cost) in Rs.
duties (vi) taxes (i)
(i) (ii) (iii) (iv) (v) (A x B) in Rs.
though (vi)]
(including Basic cost,
transportation, handling and
Insurance Charges, etc.)
(Fill taxes applicable for the item)

Fe500 MT 38000

Fe500
MT
CRS

b) 10 mm Fe415 MT

Fe500 MT 38000

Fe500
MT
CRS

c) 12 mm Fe415 MT

Fe500 MT 38000

Fe500
MT
CRS

d) 16 mm Fe415 MT

Fe500 MT 38000

Fe500
MT
CRS

C.R.Narayana Rao
Architects &Engineers 203 201-209.xls
Tidel,Coimbatore

Amount (Rs.)
SUPPLY
Total Material Cost
Entry tax- VAT-1, 2 as SEZ Project
CD/CVD ED ST/CST Total for
Materials Cost 1& 2 &3
Other Supply (C) =
Qty (B)
S.No Description Unit taxes/ (B) + [sum of
(A) (Unit Cost) in Rs.
duties (vi) taxes (i)
(i) (ii) (iii) (iv) (v) (A x B) in Rs.
though (vi)]
(including Basic cost,
transportation, handling and
Insurance Charges, etc.)
(Fill taxes applicable for the item)

e) 20 mm Fe415 MT

Fe500 MT 38000

Fe500
MT
CRS

f) 25 mm Fe415 MT

Fe500 MT 38000

Fe500
MT
CRS

g) 32 mm Fe415 MT

Fe500 MT 38000

Fe500
MT
CRS

6 Structural Steel

a Rolled Sections

C.R.Narayana Rao
Architects &Engineers 204 201-209.xls
Tidel,Coimbatore

Amount (Rs.)
SUPPLY
Total Material Cost
Entry tax- VAT-1, 2 as SEZ Project
CD/CVD ED ST/CST Total for
Materials Cost 1& 2 &3
Other Supply (C) =
Qty (B)
S.No Description Unit taxes/ (B) + [sum of
(A) (Unit Cost) in Rs.
duties (vi) taxes (i)
(i) (ii) (iii) (iv) (v) (A x B) in Rs.
though (vi)]
(including Basic cost,
transportation, handling and
Insurance Charges, etc.)
(Fill taxes applicable for the item)

Ready Mix Concrete at


7 site, including pumping,
placement

a M 25 Grade Cum

b M 30 Grade Cum

c M 45 Grade Cum

Ready Mix Concrete at


site, including pumping,
8 placement with
temperature controlled at
23 C at site.

a M 25 Grade Cum

b M 30 Grade Cum

c M 45 Grade Cum

C.R.Narayana Rao
Architects &Engineers 205 201-209.xls
Tidel,Coimbatore

Amount (Rs.)
SUPPLY
Total Material Cost
Entry tax- VAT-1, 2 as SEZ Project
CD/CVD ED ST/CST Total for
Materials Cost 1& 2 &3
Other Supply (C) =
Qty (B)
S.No Description Unit taxes/ (B) + [sum of
(A) (Unit Cost) in Rs.
duties (vi) taxes (i)
(i) (ii) (iii) (iv) (v) (A x B) in Rs.
though (vi)]
(including Basic cost,
transportation, handling and
Insurance Charges, etc.)
(Fill taxes applicable for the item)

B FINISHES

1 Solid Block Work


a 200 mm thick Each
b 150 mm thick Each
c 100 mm thick Each

2 Hollow Block Work

a 200 mm thick Each


b 150 mm thick Each
c 100 mm thick Each
3 Flush Shutter

a 32 mm thick
b 35 mm thick
4 Fire Rates Stel Door

a 2 Hour Fire
b 1 Hour Fire
5 Patch Fitting Door

a Patches
b Laminated Glass - 10 mm
6 Sliding Door

C.R.Narayana Rao
Architects &Engineers 206 201-209.xls
Tidel,Coimbatore

Amount (Rs.)
SUPPLY
Total Material Cost
Entry tax- VAT-1, 2 as SEZ Project
CD/CVD ED ST/CST Total for
Materials Cost 1& 2 &3
Other Supply (C) =
Qty (B)
S.No Description Unit taxes/ (B) + [sum of
(A) (Unit Cost) in Rs.
duties (vi) taxes (i)
(i) (ii) (iii) (iv) (v) (A x B) in Rs.
though (vi)]
(including Basic cost,
transportation, handling and
Insurance Charges, etc.)
(Fill taxes applicable for the item)

7 Hardwares

a Vision panel
b Hinge
c Flush Bolt

Wood Scantlings upto


8
24 mm to any size

a Teak Wood
b Padauk Wood

c Malaysian sal

Wooden Planks upto 20


9
mm to any size

a Teak Wood
b Padauk Wood
c Malaysian sal

Commercial plywood of
10
following items

a 6 mm thick
b 9 mm thick
c 12 mm thick
d 19 mm thick

C.R.Narayana Rao
Architects &Engineers 207 201-209.xls
Tidel,Coimbatore

Amount (Rs.)
SUPPLY
Total Material Cost
Entry tax- VAT-1, 2 as SEZ Project
CD/CVD ED ST/CST Total for
Materials Cost 1& 2 &3
Other Supply (C) =
Qty (B)
S.No Description Unit taxes/ (B) + [sum of
(A) (Unit Cost) in Rs.
duties (vi) taxes (i)
(i) (ii) (iii) (iv) (v) (A x B) in Rs.
though (vi)]
(including Basic cost,
transportation, handling and
Insurance Charges, etc.)
(Fill taxes applicable for the item)

e 25 mm thick

11 Water Proof plywood

a 6 mm thick
b 9 mm thick
c 12 mm thick
d 19 mm thick
e 25 mm thick
Plain Medium Density
12
Fibre Board

a 6 mm thick
b 9 mm thick
c 12 mm thick
d 19 mm thick
e 25 mm thick
13 Vitrified Ceramic Tiles
14 Granite Slab
15 Kotah Stone

C.R.Narayana Rao
Architects &Engineers 208 201-209.xls
Tidel,Coimbatore

Amount (Rs.)
SUPPLY
Total Material Cost
Entry tax- VAT-1, 2 as SEZ Project
CD/CVD ED ST/CST Total for
Materials Cost 1& 2 &3
Other Supply (C) =
Qty (B)
S.No Description Unit taxes/ (B) + [sum of
(A) (Unit Cost) in Rs.
duties (vi) taxes (i)
(i) (ii) (iii) (iv) (v) (A x B) in Rs.
though (vi)]
(including Basic cost,
transportation, handling and
Insurance Charges, etc.)
(Fill taxes applicable for the item)

MISCELLANEOUS
C
WORKS

1 Expansion Joint
2 Laminates 1.5 mm tk
3 Veneer - 3.5 mm tk

Other Materials
( Contractor Should
Specify )

C.R.Narayana Rao
Architects &Engineers 209 201-209.xls
Tidel, Coimbatore Summary

TIDEL PARK COIMBATORE LTD


( A JV OF TIDCO, ELCOT, TIDEL & STPI )
BUILDING COMPLEX OF INFORMATION TECHNOLOGY PARK AT VILANKURICHI
(SEZ AREA), COIMBATORE

BILLS OF QUANTITIES FOR SHELL & CORE, CIVIL FINISHES & SUBSIDIARY WORKS

GENERAL SUMMARY (FOR REFERENCE ONLY)


MATERIALS SUPPLY Labour Charges TOTAL Amount
S.No Description of work
Basic cost Taxes Amount (A) Basic cost Taxes Amount (B) (A) + (B)

SECTION 3A - MAIN BUILDING - SHELL & CORE

1 Earthwork Excavation

2 A nti-Termite Treatment Works

3 Plain & Reinforced Cement Concrete Works

4 Form Works

5 Iron & Steel Works

5 Post - Tensioning Works

6 Water Proofing Works

7 Miscellaneous Works
Sub - Total of 3 A in Rs.

SECTION 3B - MAIN BUILDING - CIVIL FINISHES MATERIALS SUPPLY Labour Charges TOTAL Amount
(A) + (B)
1 Masonry Works Basic cost Taxes Amount (A) Basic cost Taxes Amount (B)

2 Flooring & Dadoing Works

3 Joinery Works

4 Internal & External Finishes


Sub - Total of 3 B in Rs.

C.R. Narayana Rao Part - II - Bills of Quantities


Architects & Engineers 210
Tidel, Coimbatore Summary

MATERIALS SUPPLY Labour Charges TOTAL Amount


S.No Description of work
Basic cost Taxes Amount (A) Basic cost Taxes Amount (B) (A) + (B)

SECTION 3C - SUBSIDIARY WORKS MATERIALS SUPPLY Labour Charges TOTAL Amount


Basic cost Taxes Amount (A) Basic cost Taxes Amount (B) (A) + (B)
1 Roads & Pathways

2 Drains &Trenches

3 Compound Wall

4 HSD Tank

5 Sewage Treatment Works

6 UnderGround Sump
Sub - Total of 3 C in Rs.

SECTION 3 D - SUB-STAION BUILDINGS, SECURITY & DRIVER'S REST


MATERIALS SUPPLY Labour Charges TOTAL Amount
ROOM
(A) + (B)
1 Sub-Station Buildings Basic cost Taxes Amount (A) Basic cost Taxes Amount (B)

2 Secutiry Buuilding

3 Driver's Rest Room


Sub - Total of 3 D in Rs.

Grand Total of 3A to 3 D in Rs.

Date : Signature of the Contractor


Place :

C.R. Narayana Rao Part - II - Bills of Quantities


Architects & Engineers 211

Vous aimerez peut-être aussi