Vous êtes sur la page 1sur 7

Specification Sheet Form Rev.

12-09-2013

Sales Administration Use Only

Quote Name Quote Revision Shop Order Number Serial Number(s) Date
Customer : Customer Name

Salesperson : Salesperson Name

Model : ST 5200 23 D2, Standard Duty Petroleum Truck Tank


Part / Drawing Number : 721-0026T
Customer Furnished Tractor Data Required Weights to Include Driver, Fuel, Tools, Equipment, etc.

Enable Track Changes on the Review Tab to identify deviation from the Base Model Specification

A. VESSEL

A1. Shell Material Aluminum - 5454 alloy. All sizes/gauges are nominal.
Top: 0.182in
Sides: 0.182in
Bottom: 0.204in

A2. Shell and Head Enhanced mill finish bulk trailer sheet.
Finish

A3. Shape Elliptical, 23.27 GPI


(3) bolster mounts with 4 pitch to rear.

A4. Specification DOT 406

A5. Vapor Testing Tested at 5 PSI rated at 3.3 PSI. Vapor tested and certified to EPA Method 27-CA Air
Resources Board standards and manholes sealed.

A6. Nominal 5,200 gallons nominal plus 3% outage


Capacity Shell full capacity is 5,400 gallons
60 gallons is the minimum outage for any size compartment.

A7. Compartments 2 Compartments, front to rear 3600/1800 shell full

A8. Bulk Heads Aluminum - 5454 alloy. All sizes/gauges are nominal.
Front: 0.250in unstiffened
Rear: 0.250in unstiffened
Compartments: 0.204in unstiffened

Double Bulkheads between all compartments

A9. Surge Heads Aluminum - 5454 alloy. All sizes/gauges are nominal.
Over mount(s): 0.204in unstiffened
Middle of Tank: 0.204in unstiffened

All surge heads are dished & flanged with (1) 20" man way center, (2) 12" drain holes
6 and 12 o'clock, and (2) 3" emergency drain holes @ 3 and 9 o'clock.

Quality Performance Safety Value Customer Support


Page 1 of 7
Approved Initials____________________________
Specification Sheet Form Rev. 12-09-2013

A10. Flashing Full length, double leg extrusions. Dams front and rear with transverse overturn
protection rails as required by code.

Test couplings installed inside the flashing rail, at rear.


A11. Documentation Computer generated calibration charts in 1/4in increments.
HM-183 documentation with markings
Vapor test decal with documentation.
Locate markings on shell, streetside above and behind #1 bolster
Exhibit C loading documentation included.
Unit hydrostatically tested.
Tesoro form for test documentation
Conoco-Philips form for test documentation

A12. Operating -20F to 180F


Temperature
A13. Lading Gasoline, Diesel Fuel, or similar

A14. Miscellaneous None

B. TANK FITTINGS AND PIPING


B1. Manholes (1) 16" Civacon offset manhole per compartment.
Includes NV3000 PV Valve,10 aluminum vent, and Buna N gaskets. Meets HM 183
and CFR49 178.364-10 venting requirements.

B2. Capacity If ordered, each capacity indicator rod will come with one disc.
Indicators Additional discs may be ordered.
Indicator Rods: None
Additional Discs: None

B3. Internal Ground (1) 1/8" stainless steel static ground wire per compartment.

B4. Venting DOT406 venting in manhole.

B5. Cleanouts/ None


Fill Covers

B6. Vapor Recovery (1) 3" Civacon air operated inward opening sequential vent per compartment.
Vent Located in each manhole cover.
Location: Aluminum vent with stainless trim & Viton seats.
Materials:

B7. Vapor Recovery Black Nylon vapor recovery nipple connected to flashing rail
Connection A hose connects the vapor recovery vent to the vapor recovery nipple

B8. Vapor Recovery 4" Aluminum Internal vapor line from flashing rail through tank behind rear bolster.
Piping Line to continue to the following locations:

(1) curbside outlet forward of discharge piping, above truck frame (maintain 9
radius of clearance). (4" outlet).

B9. Vapor Recovery (1) 4" cam adapter for curbside outlet
Fittings

Quality Performance Safety Value Customer Support


Page 2 of 7
Approved Initials____________________________
Specification Sheet Form Rev. 12-09-2013

B10. Additional None


Venting
TM
B11. Emergency Valve (1) Civacon 5 x 4 MaxAir II , internal cylinder, EV per compartment

Materials: Aluminum body with Teflon seat.

Splash shield-vortex breaker over each EV.

To simplify piping, a straight valve may be used in place of an elbow style.

B12. Operator System (1) Bendix PP1 push button air control kit.
Location: Mounted in bottom load panel above API head

Air gauge mounted in bulkhead fitting in bottom load panel

One emergency trip located street side, front of tank.

B13. Piping/Piping 4" Schedule #10 aluminum discharge piping


Gasket
Viton gaskets on flanged piping connections
Baylast gaskets on Dixon-Bayco Aluminum groove-groove connections

B14. Bottom Load (1) 4" Civacon openable adapter per compartment
Adapter Extended to a plane drawn between end of bumper and outside edge of rear tire

Aluminum handle and Viton seals


Materials:
B15. Curbside (1) 4" API to 4" cam style hose adapters and caps
Discharge (1) API dust cap.

(1) Crown top (Ethanol) sight glass per compartment


Install upstream of curbside bottom load adapter
B16. Streetside None
Discharge
B17. Pump Off-Line None

B18. Overfill System Civacon, OptiLink, 5 wire system


Monitor Location: No monitor

Probe: (1) top probe per compartment


Location: Installed in manhole cover

Socket: (1) Optic socket (Ref. SJ6W-WOGA).


Socket Location: On bottom load panel adjacent to monitor, not in enclosure.
Ground proving device is included with the socket.

B19. Brake Interlock Individual interlock on Bottom Load Adapter(s) and curbside vapor outlet(s).

Interlock valve on API head locks brakes


Interlock valve on curbside vapor outlets locks brakes and charges internal air system.

B20. Overfill Interlock None

Quality Performance Safety Value Customer Support


Page 3 of 7
Approved Initials____________________________
Specification Sheet Form Rev. 12-09-2013

B21. Miscellaneous Trucknology commodity tag with decal wrap (9442-0013) per compartment
Mounted on bottom load panel above each API head

C. ACCESSORIES
C1. Ladder Rear, Low Profile, aluminum ladder, center of head, with serrated rungs and platform
top step

Grab handles inside of flashing rails.

Bolt-on .204 aluminum deck plate with skid resistant tape over frame rails from rear
head to frame end

C2. Walkway Adhesive backed, skid-resistant tape between flashing rails.


Walkway drains through rear ladder

C3. Hose Carriers (1) Double hose tube kit.

Size: 7in x Full Length


Material: Aluminum, reinforced for extended wear
Location: Curbside
Door: Single door at rear

(1) Single hose tube kit.

Size: 7in x Full Length


Material: Aluminum, reinforced for extended wear
Location: Streetside
Door: Single door at rear

C4. Stick Tube (1) calibration stick tube


Size: 2" diameter x 16 long
Material: SCH10 aluminum pipe
Location: Mounted curbside between hose tubes. Do not weld to hose tubes

Closure: Capped at front, rear opening covered by tab on hose tube door

C5. Cabinets (1) 30W x 18H x 18D Protech aluminum cabinet, single door, hinged down with
cable
Location: Mount on truck frame, curbside between tandem and lift axle of truck

C6. Splash Guard HEIL, anti-sail, anti-spray flaps.

C7. Fenders (2) Double contour rear fenders, ribbed aluminum


(2) Spindle mounted 12 aluminum full contour lift axle fenders.

Quality Performance Safety Value Customer Support


Page 4 of 7
Approved Initials____________________________
Specification Sheet Form Rev. 12-09-2013

C8. Placards\Doc. (4) Label Master #80SM "Slidemaster" single piece placard holders and brackets.
Holders
curbside, on hose tube bracket at #2 bolster
Location(s): streetside on #2 bolster
rear to streetside
front, on bumper bracket to curbside

C9. Lights and 12 Volt Truck-Lite flange mount LED lamp system complying to FMVSS
Visibility

Tail (3) lights per side in aluminum light boxes mounted on truck frame at rear per the
following:
(1) Red stop/tail mounted inboard
(1) White/Clear back-up mounted center
(1) Amber turn signal mounted outboard

Turn (1) Sequential turn signal per side


Mounted in angled aluminum housings near #2 bolster, each side.

Clearance/Marker (2) Clearance Lights per side, mounted per the following:
Mount rear clearance light on tank shell on horizontal plane with pull trailer lights.
Mount front clearance lights and reflectors below drivers mirrors on bottom rear of
placard bracket on #2 bolster.

(1) Clearance Light per side, mounted on tail light boxes

ID Cluster Flush mount trailer ID lights in rear dam

License (1) License frame, LED license light and four (4) nutserts on streetside.

Work Light(s) Betts B-305 swivel LED spotlight mounted to the rear of discharge piping to illuminate
work area.

Conspicuity Conspicuity markings each side and rear complying to FMVSS, including:
Full width and continuous conspicuity tape on rear bumper
Full length conspicuity tape on curbside hose tubes
Full length conspicuity tape on streetside hose tube
Streetside tape rail bolted between bolsters

Security Rings Stainless Steel security rings installed on flange mounted lights

C10. Wiring 12-volt system, 7 wire, heavy duty Heil molded conduit throughout, all connections
made in Truck-Lite 20-terminal junction box(s) mounted on plate attached to truck
cross member, facing aft. (No wiring or clips on heads).

Ground strap from tank to existing bolt on truck frame.


Leave a neat loop of extra wire at junction box for each wire connection. Leave a loop
of extra 7-wire cable tucked neatly into truck frame for Heil supplied 7-way receptacle
at rear.

Clearance lights, ICC cluster on Black. License plate light and tail lights on Brown.
Inside stop lights on Red. Streetside turn signals on Yellow. Curbside turn signals on
Green. Work lights and overfill on Blue.
Quality Performance Safety Value Customer Support
Page 5 of 7
Approved Initials____________________________
Specification Sheet Form Rev. 12-09-2013

C11. Miscellaneous Sentry 20# fire extinguisher on truck frame, streetside forward of tandem.
HEIL nameplate on center of front dam and over hitch at rear.

D. CHASSIS
D1. Bumper 84W steel bumper with skid resistant tape, mounted with 18 min. ground clearance.
Safety coupler mounted between hitch and bumper. Mount 7-way and ABS
receptacle in bumper verticals, streetside below hitch. Mount gladhands in bumper
vertical, one on each side and below hitch.

D2. Hitch Height Pintle Hitch to be 34 inches from ground, +/- 2in

D3. Paint DuPont Imron 5000 series black (N0001HN) paint on steel parts only

D4. Warranty Heils standard four year warranty - one year bumper to bumper coverage with some
areas (e.g., barrel and frame) being extended on a pro-rated basis out as much as 4
years.

Heils value package includes Civacons 3 year System3 component warranty.

Heils value package includes Duponts prorated 3 year warranty on steel parts and
prorated 4 year warranty on aluminum parts.

D5. Customer Parts None

E. TRUCK
CHASSIS
E1. Front Axle

E2. Tandem

E3. Lift/Pusher Axle

E4. Wheel Base

E5. CA

E6. AF

E7. Hitch Height

E8. Frame Rake


Laden:
Unladen:
E9. Transmission

E10. ISO ABS


Connector
E11. Serial Number(s)

Quality Performance Safety Value Customer Support


Page 6 of 7
Approved Initials____________________________
Specification Sheet Form Rev. 12-09-2013

Quality Performance Safety Value Customer Support


Page 7 of 7
Approved Initials____________________________

Vous aimerez peut-être aussi