Vous êtes sur la page 1sur 115

AutoCAD Standards Guide

Version 2004
January 2004

Prepared by: Engineering Standards Branch,


Highways and Business Servicess Applications Solution Branch,
Ministry of Transportation
Contact: Application Resource Desk
(905) 704-2423
AutoCAD Standards Guide
Version 2004
January 2004

Prepared by: Engineering Standards Branch, ISBN 0-7794-6739-6


Highways and Business Services Applications Solution Branch 2004, Queen's Printer for Ontario
Contact: Application Resource Desk Reproduced with permission.
(905)704-2423
To all users of this publication:

The information contained herein has been carefully compiled and is believed to be
accurate at the date of publication. Freedom from error, however, cannot be guaranteed.

Enquires regarding the purchase and distribution of this manual should be directed to:

Publications Ontario

By telephone: 1-800-668-9938
By fax: (613) 566-2234
TTY: 1-800-268-7095
Online: www.publications.gov.on.ca

Enquires regarding amendments, suggestions, or comments should be directed to the


Ministry of Transportation at (905) 704-2065.
REVISION SUMMARY

Document Date Summary of Changes


Revision
1.0 Feb. 1997
1.1 Nov. 1997 - Revised OPSD Layer Standards
2.0 Dec. 1998 - Updated AutoCAD Text Style Standard
- Additional Custom MTO LineTypes
- Updated AutoCAD Colour Assignments for Plot Pen Mapping
- Removed AutoCAD Menu Customization Standards
- Revised Electrical Design Drawing Standards
- Revised Photogrammetry Drawing Standards
- Revised Planning & Design Drawing Standards
- Revised Surveys & Plans Drawing Standards
- Revised Traffic Drawing Standards
- IESCAD Customization Modules available for:
Photogrammetry
Planning & Design
Surveys & Plans
- Digital prototype drawings and symbols available for:
Electrical Design
2.1 May 2000 - IESCAD Customization Modules available for:
Electrical
Traffic
OPSD
Structural

3.0 Jan. 2001 - No changes


3.0.1 Oct. 2002 - No changes
2004 Jan. 2004 - Revised OPSD Layer Standards
- Added Geotechnical and Foundations layer standards
MTO AutoCAD Standards Guide January 2004
Version 2004

CONTACTS FOR AUTOCAD LAYERING CONVENTION STANDARDS

BUSINESS FUNCTION CONTACT PERSON OFFICE PHONE NUMBER


LOCATION

Surveys and Plans Ron Berg St. Catharines (905) 704-2330


2nd Floor

Planning and Design Hanna Hanna St. Catharines (905) 704-2272


2nd Floor

Structural Design Tony Merlo St. Catharines (905) 704-2384


2nd Floor

Electrical Engineering Elizabeth Bojanowska St. Catharines (905) 704-2219


2nd Floor

Advanced Traffic Management Gilbert May Downsview (416) 235-5606


Atrium Tower, 6th Floor

Geotechnical Stan Morris Eastern Region, (613) 544-2220


Geotechnical

Photogrammetry Ron Berg St. Catharines (905) 704-2330


2nd Floor

Drainage and Hydrology Art Groenveld St. Catharines (905) 704-2239


2nd Floor

Foundation Design David Dundas Downsview, 3rd Floor, (416) 235-3731


Central Building

Traffic Mazda Hodiwala St. Catharines (905) 704-2954


2nd Floor

Environmental Nick Close St. Catharines (905) 704-2229


Mezzanine Level

Ontario Provincial Standards Victor Weziak St. Catharines (905) 704-2280


2nd Floor
MTO AutoCAD Standards Guide January 2004
Version 2004

TABLE OF CONTENTS

1.0 INTRODUCTION........................................................................................................................................................1

2.0 CAD LAYER NAMING..............................................................................................................................................2


2.1 FEATURE-ORIENTED LAYER NAMING CONVENTION ................................................................................................... 3
2.2 DRAFTING-ORIENTED LAYER NAMING CONVENTION .................................................................................................. 5

3.0 AUTOCAD TEXT STYLE STANDARD.....................................................................................................................7


3.1 CUSTOM AUTOCAD TEXT FONT ................................................................................................................................. 8

4.0 CUSTOM MTO LINE TYPES...................................................................................................................................9


4.1 DEFINITIONS OF CUSTOM MTO LINE TYPES ......................................................................................................... 10

5.0 STANDARD PLOT ASSIGNMENTS.......................................................................................................................12


5.1 AUTOCAD COLOUR ASSIGNMENTS............................................................................................................................ 13
5.2 LEROY EQUIVALENT .................................................................................................................................................. 14

6.0 STANDARD AUTOCAD SYMBOLS ......................................................................................................................15

APPENDIX A: LAYER STANDARDS ..........................................................................................................................16


APPENDIX A-1 - ADVANCED TRAFFIC DRAWINGS
APPENDIX A-2 - ELECTRICAL DESIGN DRAWINGS
APPENDIX A-3 - ENVIRONMENTAL DRAWINGS
APPENDIX A-4 - FOUNDATION DRAWINGS
APPENDIX A-5 - GEOTECHNICAL DRAWINGS
APPENDIX A-6 - ONTARIO PROVINCIAL STANDARD DRAWINGS
APPENDIX A-7 - PLANNING & DESIGN DRAWINGS
APPENDIX A-8 - PHOTOGRAMMETRY DRAWINGS
APPENDIX A-9 - SURVEYS & PLANS DRAWINGS
APPENDIX A-10 - STRUCTURAL DRAWINGS
APPENDIX A-11 - TRAFFIC DRAWINGS
APPENDIX A-12 - GOTECHNICAL DRAWINGS
APPENDIX A-13 - FOUNDATIONS DRAWINGS
MTO AutoCAD Standards Guide January 2004
Version 2004

1.0 INTRODUCTION

One of the major objectives of the Ontario Ministry of Transportations Integrated Engineering System (IES) project is to
establish standards across engineering disciplines from Surveys to Construction. As the fundamental element of integration,
everyone involved must consistently apply standards. The application of standards is therefore critical to the success of IES and
ultimately to the success of the pre-contract engineering process.

This document specifically targets standards as applied to Computer Aided Drafting (CAD) conventions to be applied during the
preparation and delivery of engineering drawings. The mandate - to be formalized as a directive - is that all CAD produced
MTO capital contract drawings must adhere to the standards outlined in this document.

This document has been created to establish standards for application of AutoCAD as the common CADD tool for the creation
of Pre-Contract Engineering drawings.

Standards are included in this document for the following areas:

* Drawings
- Layer Names & definitions
- Text Fonts
- Line Styles
- Symbols

* Plot Configurations

All functional areas in the Ministry responsible for producing Contract Drawings have agreed to the following standards and
conventions.

1
MTO AutoCAD Standards Guide January 2004
Version 2004

2.0 CAD LAYER NAMING

Due to the different requirements, purpose, and level of detail of engineering drawings, two layer naming approaches have been
established as standards:

A. Feature Oriented:

Layer names identify specific objects (linework, symbols) associated with the highway construction process (e.g. catch
basin, traffic signal box).
Layer names permit identification and manipulation of objects by name for viewing, plotting, querying, determining unit,
linear and area quantities.
All drafting information such as text, dimensions, hatch patterns are identified as entities associated to features, on
separate layers.

B. Drafting Oriented:

Layer names identify how objects are to be viewed (colour, linestyle) and plotted.
Acceptable for drawings, which do not contain features, that would be individually queried or manipulated.

Both feature and drafting oriented drawings often originate in one section and enter a work flow cycle to other offices for addition
of function-specific features. Although two different layer naming approaches are established as standards, an attempt has been
made to maintain the underlying conventions throughout.

2
MTO AutoCAD Standards Guide January 2004
Version 2004

2.1 Feature-Oriented Layer Naming Convention

The feature-oriented approach applies to the following type of drawings:

- Plan
- Profile
- Removals
- Detail

The following are guidelines used to develop the Layer Naming approach for preparation of these types of Ministry contract
drawings:

1. The Layer Name will:


i. Be "feature-oriented"
ii. Be hierarchical in nature
iii. Consist of several components, delineated by dashes

2. The first component is a mandatory code that will identify the originating office or engineering discipline.

3. The second component is a mandatory code that will indicate the status (New, Existing, Removal, and
Future) of the features on that layer.

4. The Feature Code component of the layer name is the responsibility of each office, and can be as specific or
general as the office wishes. Features may be grouped or specified individually.

5. The last component of the layer name will be an optional definition of non-feature oriented data (i.e. text,
dimensions, patterns), which could be placed on a separate layer.

The Layer Naming convention described above is as follows:

AA-B-C-C-C-C-C-D Maximum of 31 characters for entire layer name, including dashes.

AA - An abbreviated code identifying the engineering discipline with "custodianship" of the layer:

i.e.: AT - Advanced Traffic


DH - Drainage & Hydrology
FD - Foundation
GE - Geotechnical
EL - Electrical
EN - Environmental
OPS - Ontario Provincial Standards (see Section 2.2)
PD - Planning & Design
PH - Photogrammetry
SP - Surveys & Plans
ST - Structural
TR - Traffic

3
MTO AutoCAD Standards Guide January 2004
Version 2004

B - Single character code identifying the "status" of the drawing feature. (See guideline 3)

i.e. E - Existing
F - Future Feature
N - New Construction
R - Removals
A - As Constructed

C-C-C-C-C - Feature specification of between 1-5 individual identifiers, hierarchically describing a drawing
feature in progressive detail.

i.e. RDS-EP - Roadway, Edge of Pavement


DRN-CB - Drainage, Catch Basin

D- Optional single character code identifying the group name of graphical entities associated to a feature.

i.e. D - Dimensions
P - Patterns (Hatching)
T - Text (Annotation)

Examples:

SP-E-VEG-WO Surveys & Plans layer, existing, vegetation, woods.

PD-N-DRN-CB Planning & Design layer, new, drainage, catch basin.

PD-N-DRN-CV-T Planning & Design layer, new, drainage, culvert, text.

4
MTO AutoCAD Standards Guide January 2004
Version 2004

2.2 Drafting-Oriented Layer Naming Convention

The layer naming approach used for Ontario Provincial Standards drawings (OPSDs), Typical Sections, and any drawing entities that
are not feature specific will adhere to the "Drafting Oriented" convention. This approach identifies layers by how objects are to be
viewed (colour, linestyle) and plotted.

The following are guidelines used to develop the Layer Naming approach for preparation of these types of Ministry contract drawings:

1. The Layer Name will:


i. Identify the drafting entity
ii. Consist of several components, delineated by dashes

2. The first component is a mandatory code that will identify the originating office or engineering discipline.

3. The second component is a mandatory code that will indicate the General status of the drawing entities on that
layer.

4. The remaining component of the layer name is used to specify the drafting entity type.

The Layer Naming convention described above is as follows:

AA-B-C-C Maximum of 31 characters for entire layer name, including dashes.

AA - An abbreviated code identifying the engineering discipline with "custodianship" of the layer:

i.e.: AT - Advanced Traffic


DH - Drainage & Hydrology
FD - Foundation
GE - Geotechnical
EL - Electrical
EN - Environmental
OPS - Ontario Provincial Standards (see Section 2.2)
PD - Planning & Design
PH - Photogrammetry
SP - Surveys & Plans
ST - Structural
TR - Traffic

B - Single character code identifying the "status" of the drawing feature.

i.e. G - General
S - Standard Drawing
T - Typical Section

5
MTO AutoCAD Standards Guide January 2004
Version 2004

C - Entity specification describing the type of entities to be placed on this layer or the pen thickness assigned.

i.e. TEXT - text entities


SYMBOLS - symbols or block entities
25MM - 2.5mm plot pen
30MM - 3.0mm plot pen
40MM - 4.0mm plot pen
50MM - 5.0mm plot pen
60MM - 6.0mm plot pen

Examples:

SP-G-25MM Surveys & Plans layer, general (non-feature specific), 2.5mm lines.

PD-T-40MM Planning & Design layer, typical section, 4.0mm lines

PD-G-TEXT Planning & Design layer, general (non-feature specific), text.

6
MTO AutoCAD Standards Guide January 2004
Version 2004

3.0 AutoCAD TEXT STYLE STANDARD

The following table contains the standard for AutoCAD text styles.

Text Style Name Leroy Text Height Plot Pen AutoCAD


Equivalent Thickness Colour
TEXT15 060 1.50mm 0.20mm 1
TEXT20 080 2.00mm 0.25mm 2
TEXT25 100 2.50mm 0.30mm 7
TEXT30 120 3.00mm 0.40mm 3
TEXT35 140 3.50mm 0.40mm 3
TEXT45 175 4.50mm 0.50mm 4
TEXT50 200 5.00mm 0.60mm 5
TEXT60 240 6.00mm 0.60mm 5
TEXT75 290 7.50mm 0.75mm 6
TEXT90 350 9.00mm 1.00mm 10
TEXT100 425 10.00mm 1.00mm 10
TEXT125 500 12.50mm 1.25mm 11
TEXT150 600 15.00mm 1.50mm 12
TEXT200 20.00mm 1.50mm 12

TEXT15B 060 1.50mm 0.20mm 1


TEXT20B 080 2.00mm 0.25mm 2
TEXT25B 100 2.50mm 0.30mm 7
TEXT30B 120 3.00mm 0.40mm 3
TEXT35B 140 3.50mm 0.40mm 3
TEXT45B 175 4.50mm 0.50mm 4
TEXT50B 200 5.00mm 0.60mm 5
TEXT60B 240 6.00mm 0.60mm 5
TEXT75B 290 7.50mm 0.75mm 6
TEXT90B 350 9.00mm 1.00mm 10
TEXT100B 425 10.00mm 1.00mm 10
TEXT125B 500 12.50mm 1.25mm 11
TEXT150B 600 15.00mm 1.50mm 12
TEXT200B 20.00mm 1.50mm 12

Text Styles TEXT15 through TEXT150 are the standard density text styles defined with font romans.
Text Styles TEXT15B through TEXT150B are bold text styles defined with font romand.

Colour assignments for standard text entities must adhere to the MTO CAD Colour Standards/Plot Pen Assignments. Exceptions to the
colour assignments are permitted where required for readability.

7
MTO AutoCAD Standards Guide January 2004
Version 2004

3.1 Custom AutoCAD Text Font

The standard Text Font used is AutoCADs ROMANS (formerly SIMLPEX).

In certain cases, additional special characters are required and for convenience have been included in an MTO customised Text
Font called MTOENG. MTOENG is based on AutoCADs ROMANS with the additional characters as documented below.

Custom Text Font MTOENG

Standard Characters - based on Roman Simplex (romans.shx)


abcdefghijklmnopqrstuvwxyzABCDEFGHIJKLMNOPQRSTUVWXYZ
1234567890-=[];'`,./!@#$%^&*()_+{}:"~<>?

Special Characters Custom Special Characters


C
%%c %%150 L
%%d %%151 superscript
%%o overscored %%152 sub script
P
%%p %%153 L
%%u underscored %%154 a
%%% % %%155
%%156 g
%%157

8
MTO AutoCAD Standards Guide January 2004
Version 2004

4.0 CUSTOM MTO LINE TYPES

The figure below illustrates the custom MTO line types. The actual line-gap specifications are defined in Section 4.1.

9
MTO AutoCAD Standards Guide January 2004
Version 2004

Definitions of Custom MTO Line Types

Line Type Name Line Gap Line Gap Line Gap Line Gap

SHORTDASH 2.0 1.0


LONGDASH 18.0 2.0
MEDDASH 9.0 2.0
1MMDOT 0.0 1.0
DASH1 3.0 1.5

COUNTY 15.0 2.0 1.0 2.0


TOWNSHIP 15.0 1.25 3.75 1.25 3.75 1.25
HIGHWAY 15.00 5.0
DISPOSAL 7.5 5.0
R-O-W 20.0 5.0
ROW-PRI 1.0 1.0
ROW-PRU 2.0 2.0
ROW-PLI 4.0 1.0 1.0 1.0
ROW-TLI 2.0 1.0 1.0 1.0

GR-DRIVE 3.75 1.25


GR-ROAD 7.5 2.5
CABLE 20.0 10.0
FENCE 20.0 1.25 2.5 1.25
UTILITY 20.0 1.25 2.5 1.25 2.5 1.25
LANE 8.0 8.0
SLOPE 2.0 0.5

SUBGRADE 5.0 1.0


DITCHRT 6.0 1.0 0.8 1.0
DITCHLT 6.0 1.0 0.8 1.0 0.8 1.0
DITCHM 6.0 1.0 0.8 1.0 0.8 1.0 0.8 1.0
CUTRT 5.0 1.0 0.4 1.0
CUTLT 5.0 1.0 0.4 1.0 0.4 1.0
SLOPERT 10.0 1.0 0.4 1.0
SLOPELT 10.0 1.0 0.4 1.0 0.4 1.0
ROCK 4.0 1.0
MUSKEG 3.0 0.5
EARTH 2.0 0.5

TYPCL 12.5 1.25 2.0 1.25


TYPDASH 3.175 0.6
TYPOG 3.75 1.25

CL1 20.0 1.5


CL2 10.0 1.0 1.0 1.0
CL3 5.0 1.0 1.0 1.0
CL4 2.0 0.75 0.75 0.75
DL1 1.0 0.5
DL2 1.25 1.0
DL3 2.5 1.0

10
MTO AutoCAD Standards Guide January 2004
Version 2004

Line Type Name Line Gap Line Gap Line Gap Line Gap
DL4 3.0 1.0

DL5 5.0 1.0 0.0 1.0


DL6 8.0 2.0
DL7 2.0 1.0 1.0 1.0
DL8 20.0 20.0
DL9 6.0 1.5

DL11 0.75 0.75


DL12 3.0 0.75

PMK1 3.0 3.0


PMK2 3.0 6.0
PMK3 3.0 9.0

BUSH * patterned line type


HEDGE * patterned line type
GUIDERAIL * patterned line type
RAILROAD1 * patterned line type
PITFACEL * patterned line type
PITFACER * patterned line type
XFENCE * patterned line type

* All measurements are specified in drawing units

11
MTO AutoCAD Standards Guide January 2004
Version 2004

5.0 STANDARD PLOT ASSIGNMENTS

The table in section 5.1 represents a standard approach that facilitates the use of all 255 AutoCAD colours and supports different plot
pen thickness and half-tone/full-tone definitions for various shades of the primary colours.

In general, colours 20 through 249 can be assigned to the appropriate plot pens by adhering to the following rule:

*Colour Ending With Plot Pen Thickness (mm)


0 0.30
1 0.20
2 0.25
3 0.40
4 0.50
5 0.60
6 0.75
7 1.00

* Note - there are exceptions (please refer to the colour assignments


table for a complete reference)

12
MTO AutoCAD Standards Guide January 2004
Version 2004

5.1 AutoCAD Colour Assignments

The standard colour/pen definitions for full-tone, half-tone, and text style assignments are defined in the table below:

Pen Width 0.30mm 0.20mm 0.25mm 0.40mm 0.50mm 0.60mm 0.75mm 1.00mm 1.25mm 1.50mm
Colour Orange Red Yellow Green Cyan Blue Magenta Red Pink Dark Red

Standard 70 1 2 3 4 5 6 10 11 12
Full-tone 7-white
Colour 73 23 53 83 133 33 213 223 233 243
Half-tone
Grey 9,255 251 254 253 8 252 135 134 145 136
Half-tone
TEXT TEXT25 TEXT15 TEXT20 TEXT30 TEXT45 TEXT50 TEXT75 TEXT90 TEXT125 TEXT150
TEXT35 TEXT60 TEXT100

Additional colour/pen assignments for full-tone plotting are defined below:

COLOUR 0.30mm 0.20mm 0.25mm 0.40mm 0.50mm 0.60mm 0.75mm 1.00mm 1.25mm 1.50mm

Red 20 21 22 24 25 26 27
Orange 30 31 32 34 35 36 37
40 41 42 43 44 45 46 47
Yellow 50 51 52 54 55 56 57
60 61 62 63 64 65 66 67
71 72 74 75 76 77
80 81 82 84 85 86 87
Green 90 91 92 93 94 95 96 97
100 101 102 103 104 105 106 107
110 111 112 113 114 115 116 117
120 121 122 123 124 125 126 127
Cyan 130 131 132 137
140 141 142 143 144 146 147
150 151 152 153 154 155 156 157
Blue 160 161 162 163 164 165 166 167
170 171 172 173 174 175 176 177
180 181 182 183 184 185 186 187
Magenta 190 191 192 193 194 195 196 197
200 201 202 203 204 205 206 207
210 211 212 214 215 216 217
220 221 222 224 225 226 227
Red 230 231 232 234 235 236 237
240 241 242 244 245 246 247

13
MTO AutoCAD Standards Guide January 2004
Version 2004

5.2 Leroy Equivalent

The following table shows the standard pen thickness in millimetres and their approximate Leroy equivalents.

PEN THICKNESS (mm) PEN THICKNESS (Leroy)

0.20 4x0

0.25 3x0

0.30 00

0.40 0

0.50 1.0

0.60 2.0

0.75 2.5

1.00 3.5

1.25 4.0

1.50 6.0

14
MTO AutoCAD Standards Guide January 2004
Version 2004

6.0 STANDARD AutoCAD SYMBOLS

To avoid repetition, the standard symbols for use within AutoCAD have not been included in this manual. For a complete symbol
library, refer to the manual entitled Ontario Provincial Standard for Roads and Municipal Services. Symbols for Electrical drawings
are listed in Volume 4, Section 2000. All others are listed in Volume 3, Section 100.

15
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A: LAYER STANDARDS

16
MTO AutoCAD Standards Guide January 2004
Version 2004

Description of Layer Definition Columns

The following Appendices detail the standard AutoCAD layer definitions for the various Engineering disciplines in MTO. A brief
description of the table columns is provided below:

Layer - The AutoCAD Layer Name

LineStyle - The standard AutoCAD Line Type assigned to the layer

- For layers defined to contain only Symbols, this column indicates SYMBOLS. The
standard AutoCAD Line Type assigned to this layer is actually CONTINUOUS.

- For layers defined to contain only Text entities, this column indicates the standard
IESCAD Text style to be used (ie. TEXT25). The standard AutoCAD Line Type
assigned to this layer is actually CONTINUOUS.

Full-Tone Color# - The standard AutoCAD Colour that is assigned to this layer

Color - Description of the color#

Half-Tone Color# - The colour number associated with the layer should the features on the layer be required
to be plotted with a half-tone pen.

Plotting Color# - The colour number that the layer should be mapped to prior to plotting in order to achieve
the required pen thickness.

- This field is in the process of being discontinued. Layer standards defined in February
1997 require this definition and the associated pre-plot layer colour redefinition. Layer
standards that have been updated (as of December 1998) no longer require this
approach. Eventually this column (and the layer redefinition requirement) will be
eliminated altogether for layer standards in all Engineering disciplines.

Pen Thickness (mm) - The pen thickness that entities on this layer should be plotted for full-size contract
drawings

Description - A description of the entities that should be placed on the layer

17
MTO AutoCAD Standards Guide January 2004
Version 2004

Description of Abbreviations

Most of the Layer Names in the following tables have been grouped by common major features characteristics. For example:
SP-E-DRN-EM

In this layer name, the major feature code category is >DRN=, which represents >Drainage=, of which a number of layers apply
to.

The following is a general list describing the abbreviations for these major feature categories where layer descriptions do not
provide enough detail. Codes not illustrated here are adequately defined by the layer description.

ALI - Alignment
BAR - Barrier
BASE - Base Material
BDY - Property Boundaries
BED - Roadbed
BIN - Binder Course
CBLE - Cable
CTR - Contour
DRN - Drainage
ERTH - Earth
FSH - Fishery
FTB - Frame & Title Block
GND - Ground
LAY - Layout
MISC - Miscellaneous
MON - Survey Monuments
MSC - Miscellaneous
PIT - Pit Sketch
PMK - Pavement Markings
RDS - Roads
ROW - Right-of-Way
SIGN - Signs
SUB - Sub Base
SUBQ - Sub Surface Material
SURF - Surface Material
SYM - Symbols
TYP - Typicals
UTL - Utility
VEG - Vegetation
WIR - Wiring

18
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-1

LAYER STANDARDS

For

ADVANCED TRAFFIC DRAWINGS


ADVANCED TRAFFIC LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC-D )

Discipline (AA): The following abbreviations are used:


AT - Advanced Traffic

Status (B): The following abbreviations are used:


E - Existing Plan
F - Future
N - New Contstruction

Feature (CCC-CC):The feature portion of the layer name is defined by 2 components.


- the 1st portion indentifies a type of drawing
- the 2nd portion identifies the feature
- an optional 3rd portion (-I) is used for Identification Code layers

The following "type of drawing" abbreviations are used:


LAY - Layout
WIR - Wiring

Annotation (D): The annotation portion is generally applied at the "feature" level.
For example: AT-E-WIR-CABLE-T

app1-advtraf Page 1 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
===============
Existing Layout
===============
AT-E-LAY-CAB1 6 Magenta - 0.75 VDS Cabinets
AT-E-LAY-CAB1-I 6 Magenta - 0.75 VDS Cabinets
AT-E-LAY-CAB2 4 Cyan - 0.50 CCTV Cabinets
AT-E-LAY-CAB2-I 4 Cyan - 0.50 CCTV Cabinets
AT-E-LAY-CAB3 30 Orange 5 0.60 CMS Cabinets
AT-E-LAY-CAB3-I 30 Orange 5 0.60 CMS Cabinets
AT-E-LAY-CAB4 34 Orange - 0.50 LCS/QWS Cabinets
AT-E-LAY-CAB4-I 34 Orange - 0.50 LCS/QWS Cabinets
AT-E-LAY-CABC 7 White - 0.30 COMM Cabinets
AT-E-LAY-CABC-I 7 White - 0.30 COMM Cabinets
AT-E-LAY-CABJ1 14 Red 223 1.00 RMS & VDS Cabinets
AT-E-LAY-CABJ1-I 14 Red 223 1.00 RMS & VDS Cabinets
AT-E-LAY-CABJ2 14 Red 223 1.00 LCS/QWS & VDS Cabinets
AT-E-LAY-CABJ2-I 14 Red 223 1.00 LCS/QWS & VDS Cabinets
AT-E-LAY-CABJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS Cabinets
AT-E-LAY-CABJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS Cabinets
AT-E-LAY-CABJ4 14 Red 223 1.00 CCTV & LCS/QWS Cabinets
AT-E-LAY-CABJ4-I 14 Red 223 1.00 CCTV & LCS Cabinets
AT-E-LAY-CABJ5 14 Red 223 1.00 CMS & LCS/QWS Cabinets
AT-E-LAY-CABJ5-I 14 Red 223 1.00 CMS & LCS/QWS Cabinets
AT-E-LAY-CABLE 7 White 0.30 Cables
AT-E-LAY-CABP 1 Red 0.20 Power Supply Cabinets
AT-E-LAY-CABP-I 1 Red 0.20 Power Supply Cabinets
AT-E-LAY-CABP1 6 Magenta 0.75 VDS Cabinet with Power Supply
AT-E-LAY-CABP1-I 6 Magenta 0.75 VDS Cabinet with Power Supply
AT-E-LAY-CABP2 4 Cyan 0.50 CCTV Cab. with Power Supply
AT-E-LAY-CABP2-I 4 Cyan 0.50 CCTV Cab. with Power Supply
AT-E-LAY-CABP3 30 Orange 5 0.60 CMS Cabinet with Power Supply
AT-E-LAY-CABP3-I 30 Orange 5 0.60 CMS Cabinet with Power Supply
AT-E-LAY-CABP4 34 Orange 0.50 LCS/QWS Cabinet with Power Supply

app1-advtraf Page 2 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-E-LAY-CABP4-I 34 Orange 0.50 LCS/QWS Cabinet with Power Supply
AT-E-LAY-CABPJ1 14 Red 223 1.00 RMS & VDS Cab. with Power Supply
AT-E-LAY-CABPJ1-I 14 Red 223 1.00 RMS & VDS Cab. with Power Supply
AT-E-LAY-CABPJ2 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power Supply
AT-E-LAY-CABPJ2-I 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power Supply
AT-E-LAY-CABPJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power Supply
AT-E-LAY-CABPJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power Supply
AT-E-LAY-CABPJ4 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power Supply
AT-E-LAY-CABPJ4-I 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power Supply
AT-E-LAY-CABPJ5 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power Supply
AT-E-LAY-CABPJ5-I 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power Supply
AT-E-LAY-CABTS 7 White 0.30 Traffic Signal Controller Cabinet
AT-E-LAY-CAER 7 White 0.30 Cables
AT-E-LAY-CCTV 4 Cyan 0.50 CCTV Cameras
AT-E-LAY-CCTV-I 4 Cyan 0.50 CCTV Cameras
AT-E-LAY-COM1 7 White 0.30 Electrical Maintenance Holes
AT-E-LAY-COM1-I 7 White 0.30 Electrical Maintenance Holes
AT-E-LAY-COM2 7 White 0.30 Pedestals
AT-E-LAY-COM2-I 7 White 0.30 Pedestals
AT-E-LAY-COM3 7 White 0.30 Junction Boxes
AT-E-LAY-COM3-I 7 White 0.30 Junction Boxes
AT-E-LAY-COM4 7 White 0.30 Pull Boxes
AT-E-LAY-COM4-I 7 White 0.30 Pull Boxes
AT-E-LAY-COM5 7 White 0.30 CB
AT-E-LAY-COM5-I 7 White 0.30 CB
AT-E-LAY-CPAV 7 White 0.30 Cables
AT-E-LAY-DCEM 7 White 0.30 Ducts and/or cables
AT-E-LAY-DCSM 7 White 0.30 Ducts and/or cables
AT-E-LAY-DCUG 7 White 0.30 Ducts and/or cables
AT-E-LAY-DCUG-I 7 White 0.30 Ducts and/or cables
AT-E-LAY-DET1 6 Magenta 0.75 Detector Loops
AT-E-LAY-DET1-I 6 Magenta 0.75 Detector Loops
AT-E-LAY-PS3 1 Red 0.20 Subststions
AT-E-LAY-PS3-I 1 Red 0.20 Subststions

app1-advtraf Page 3 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-E-LAY-SIGN1 30 Orange 5 0.60 CMS Signs
AT-E-LAY-SIGN1-I 30 Orange 5 0.60 CMS Signs
AT-E-LAY-SIGN2 34 Orange 0.50 LCS/QWS Signs
AT-E-LAY-SIGN2-I 34 Orange 0.50 LCS/QWS Signs
AT-E-LAY-SIGN4 7 White 0.30 Blank Out Signs
AT-E-LAY-SIGN4-I 7 White 0.30 Blank Out Signs
AT-E-LAY-SUPP1 30 Orange 5 0.60 CMS Overhead Structures
AT-E-LAY-SUPP2 30 Orange 5 0.60 CMS footings.
AT-E-LAY-SUPP3 34 Orange 0.50 LCS/QWS Overhead Structures
AT-E-LAY-SUPP4 34 Orange 0.50 LCS/QWS Footings
AT-E-LAY-SUPP6 4 Cyan 0.50 CCTV Poles
AT-E-LAY-SUPP7 7 White 0.30 Concrete Pads.
===============
Existing Wiring
===============
AT-E-WIR-CABLE 7 White 0.30 Cables
AT-E-WIR-CABLE-T 7 White 0.30 Cables
AT-E-WIR-CAER 7 White 0.30 Cables
AT-E-WIR-CAER-T 7 White 0.30 Cables
AT-E-WIR-CPAV 7 White 0.30 Cables
AT-E-WIR-CPAV-T 7 White 0.30 Cables
AT-E-WIR-DCEM 7 White 0.30 Ducts and/or cables
AT-E-WIR-DCEM-T 7 White 0.30 Ducts and/or cables
AT-E-WIR-DCSM 7 White 0.30 Ducts and/or cables
AT-E-WIR-DCSM-T 7 White 0.30 Ducts and/or cables
AT-E-WIR-DCUG 7 White 0.30 Ducts and/or cables
AT-E-WIR-DCUG-I 7 White 0.30 Ducts and/or cables
AT-E-WIR-DCUG-T 7 White 0.30 Ducts and/or cables
AT-E-WIR-DET1 6 Magenta 0.75 Detector Loops
AT-E-WIR-DET1-I 6 Magenta 0.75 Detector Loops
===============
Future Layout
===============

app1-advtraf Page 4 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-F-LAY-CAB1 6 Magenta 0.75 VDS Cabinets
AT-F-LAY-CAB1-I 6 Magenta 0.75 VDS Cabinets
AT-F-LAY-CAB2 4 Cyan 0.50 CCTV Cabinets
AT-F-LAY-CAB2-I 4 Cyan 0.50 CCTV Cabinets
AT-F-LAY-CAB3 30 Orange 5 0.60 CMS Cabinets
AT-F-LAY-CAB3-I 30 Orange 5 0.60 CMS Cabinets
AT-F-LAY-CAB4 34 Orange 0.50 LCS/QWS Cabinets
AT-F-LAY-CAB4 34 Orange 0.50 LCS/QWS Cabinets
AT-F-LAY-CAB4-I 34 Orange 0.50 LCS/QWS Cabinets
AT-F-LAY-CAB4-I 34 Orange 0.50 LCS/QWS Cabinets
AT-F-LAY-CABC 7 White 0.30 COMM Cabinets
AT-F-LAY-CABC-I 7 White 0.30 COMM Cabinets
AT-F-LAY-CABJ1 14 Red 223 1.00 RMS & VDS Cabinets
AT-F-LAY-CABJ1-I 14 Red 223 1.00 RMS & VDS Cabinets
AT-F-LAY-CABJ2 14 Red 223 1.00 LCS/QWS & VDS Cabinets
AT-F-LAY-CABJ2-I 14 Red 223 1.00 LCS/QWS & VDS Cabinets
AT-F-LAY-CABJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS Cabinets
AT-F-LAY-CABJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS Cabinets
AT-F-LAY-CABJ4 14 Red 223 1.00 CCTV & LCS/QWS Cabinets
AT-F-LAY-CABJ4-I 14 Red 223 1.00 CCTV & LCS/QWS Cabinets
AT-F-LAY-CABJ5 14 Red 223 1.00 CMS & LCS/QWS Cabinets
AT-F-LAY-CABJ5-I 14 Red 223 1.00 CMS & LCS/QWS Cabinets
AT-F-LAY-CABLE 7 White 0.30 Cables
AT-F-LAY-CABP 1 Red 0.20 Power Supply Cabinets
AT-F-LAY-CABP-I 1 Red 0.20 Power Supply Cabinets
AT-F-LAY-CABP1 6 Magenta 0.75 VDS Cabinet with Power Supply
AT-F-LAY-CABP1-I 6 Magenta 0.75 VDS Cabinet with Power Supply
AT-F-LAY-CABP2 4 Cyan 0.50 CCTV Cab. with Power Supply
AT-F-LAY-CABP2-I 4 Cyan 0.50 CCTV Cab. with Power Supply
AT-F-LAY-CABP3 30 Orange 5 0.60 CMS Cabinet with Power Supply
AT-F-LAY-CABP3-I 30 Orange 5 0.60 CMS Cabinet with Power Supply
AT-F-LAY-CABP4 34 Orange LCS/QWS Cabinet with Power Supply
AT-F-LAY-CABP4-I 34 Orange LCS/QWS Cabinet with Power Supply
AT-F-LAY-CABPJ1 14 Red 223 1.00 RMS & VDS Cab. with Power Supply

app1-advtraf Page 5 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-F-LAY-CABPJ1-I 14 Red 223 1.00 RMS & VDS Cab. with Power Supply
AT-F-LAY-CABPJ2 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power Supply
AT-F-LAY-CABPJ2-I 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power Supply
AT-F-LAY-CABPJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power Supply
AT-F-LAY-CABPJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power Supply
AT-F-LAY-CABPJ4 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power Supply
AT-F-LAY-CABPJ4-I 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power Supply
AT-F-LAY-CABPJ5 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power Supply
AT-F-LAY-CABPJ5-I 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power Supply
AT-F-LAY-CABTS 7 White 0.30 Traffic Signal Controller Cabinet
AT-F-LAY-CAER 7 White 0.30 Cables
AT-F-LAY-CCTV 4 Cyan 0.50 CCTV Cameras
AT-F-LAY-CCTV-I 4 Cyan 0.50 CCTV Cameras
AT-F-LAY-COM1 7 White 0.30 Electrical Maintenance Holes
AT-F-LAY-COM1-I 7 White 0.30 Electrical Maintenance Holes
AT-F-LAY-COM2 7 White 0.30 Pedestals
AT-F-LAY-COM2-I 7 White 0.30 Pedestals
AT-F-LAY-COM3 7 White 0.30 Junction Boxes
AT-F-LAY-COM3-I 7 White 0.30 Junction Boxes
AT-F-LAY-COM4 7 White 0.30 Pull Boxes
AT-F-LAY-COM4-I 7 White 0.30 Pull Boxes
AT-F-LAY-COM5 7 White 0.30 CB
AT-F-LAY-COM5-I 7 White 0.30 CB
AT-F-LAY-CPAV 7 White 0.30 Cables
AT-F-LAY-DCEM 7 White 0.30 Ducts and/or cables
AT-F-LAY-DCSM 7 White 0.30 Ducts and/or cables
AT-F-LAY-DCUG 7 White 0.30 Ducts and/or cables
AT-F-LAY-DCUG-D 7 White 0.30 Ducts and/or cables
AT-F-LAY-DCUG-I 7 White 0.30 Ducts and/or cables
AT-F-LAY-DET1 6 Magenta 0.75 Detector Loops
AT-F-LAY-DET1-I 6 Magenta 0.75 Detector Loops
AT-F-LAY-SIGN1 30 Orange 5 0.60 CMS Signs
AT-F-LAY-SIGN1-I 30 Orange 5 0.60 CMS Signs
AT-F-LAY-SIGN2 34 Orange 0.50 LCS/QWS Signs

app1-advtraf Page 6 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-F-LAY-SIGN2-I 34 Orange 0.50 LCS/QWS Signs
AT-F-LAY-SIGN4 7 White 0.30 Blank Out Signs
AT-F-LAY-SIGN4-I 7 White 0.30 Blank Out Signs
AT-F-LAY-SUPP1 30 Orange 5 0.60 CMS Overhead Structures
AT-F-LAY-SUPP2 30 Orange 5 0.60 CMS footings.
AT-F-LAY-SUPP3 34 Orange 0.50 LCS/QWS Overhead Structures
AT-F-LAY-SUPP4 34 Orange 0.50 LCS/QWS Footings
AT-F-LAY-SUPP6 4 Cyan 0.50 CCTV Poles
AT-F-LAY-SUPP7 7 White 0.30 Concrete Pads.
===============
Future Wiring
===============
AT-F-WIR-CABLE 7 White 0.30 Cables
AT-F-WIR-CABLE-T 7 White 0.30 Cables
AT-F-WIR-CAER 7 White 0.30 Cables
AT-F-WIR-CAER-T 7 White 0.30 Cables
AT-F-WIR-CCTV 4 Cyan 0.50 CCTV Cameras
AT-F-WIR-CCTV-I 4 Cyan 0.50 CCTV Cameras
AT-F-WIR-COM1 7 White 0.30 Electrical Maintenance Holes
AT-F-WIR-COM1-I 7 White 0.30 Electrical Maintenance Holes
AT-F-WIR-COM2 7 White 0.30 Pedestals
AT-F-WIR-COM2-I 7 White 0.30 Pedestals
AT-F-WIR-COM3 7 White 0.30 Junction Boxes
AT-F-WIR-COM3-I 7 White 0.30 Junction Boxes
AT-F-WIR-COM4 7 White 0.30 Pull Boxes
AT-F-WIR-COM4-I 7 White 0.30 Pull Boxes
AT-F-WIR-COM5 7 White 0.30 CB
AT-F-WIR-COM5-I 7 White 0.30 CB
AT-F-WIR-CPAV 7 White 0.30 Cables
AT-F-WIR-CPAV-T 7 White 0.30 Cables
AT-F-WIR-DCEM 7 White 0.30 Ducts and/or cables
AT-F-WIR-DCEM-T 7 White 0.30 Ducts and/or cables
AT-F-WIR-DCSM 7 White 0.30 Ducts and/or cables

app1-advtraf Page 7 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-F-WIR-DCSM-T 7 White 0.30 Ducts and/or cables
AT-F-WIR-DCUG 7 White 0.30 Ducts and/or cables
AT-F-WIR-DCUG-I 7 White 0.30 Ducts and/or cables
AT-F-WIR-DCUG-T 7 White 0.30 Ducts and/or cables
AT-F-WIR-DET1 6 Magenta 0.75 Detector Loops
AT-F-WIR-DET1-I 6 Magenta 0.75 Detector Loops
AT-F-WIR-PS2 3 Green 0.40 Ground Rods
AT-F-WIR-PS3 1 Red 0.20 Subststions
AT-F-WIR-PS3-I 1 Red 0.20 Subststions
AT-F-WIR-SIGN1 30 Orange 5 0.60 CMS Signs
AT-F-WIR-SIGN1-I 30 Orange 5 0.60 CMS Signs
AT-F-WIR-SIGN2 34 Orange 0.50 LCS/QWS Signs
AT-F-WIR-SIGN2-I 34 Orange 0.50 LCS/QWS Signs
AT-F-WIR-SIGN4 7 White 0.30 Blank Out Signs
AT-F-WIR-SIGN4-I 7 White 0.30 Blank Out Signs

app1-advtraf Page 8 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
===============
New Layout
===============
AT-N-LAY-CAB1 6 Magenta 0.75 VDS Cabinets
AT-N-LAY-CAB1-I 6 Magenta 0.75 VDS Cabinets
AT-N-LAY-CAB2 4 Cyan 0.50 CCTV Cabinets
AT-N-LAY-CAB2-I 4 Cyan 0.50 CCTV Cabinets
AT-N-LAY-CAB3 30 Orange 5 0.60 CMS Cabinets
AT-N-LAY-CAB3-I 30 Orange 5 0.60 CMS Cabinets
AT-N-LAY-CAB4 34 Orange 0.50 LCS/QWS Cabinets
AT-N-LAY-CAB4-I 34 Orange 0.50 LCS/QWS Cabinets
AT-N-LAY-CABC 7 White 0.30 COMM Cabinets
AT-N-LAY-CABC-I 7 White 0.30 COMM Cabinets
AT-N-LAY-CABJ1 14 Red 223 1.00 RMS & VDS Cabinets
AT-N-LAY-CABJ1-I 14 Red 223 1.00 RMS & VDS Cabinets
AT-N-LAY-CABJ2 14 Red 223 1.00 LCS/QWS & VDS Cabinets
AT-N-LAY-CABJ2-I 14 Red 223 1.00 LCS/QWS & VDS Cabinets
AT-N-LAY-CABJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS Cabinets
AT-N-LAY-CABJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS Cabinets
AT-N-LAY-CABJ4 14 Red 223 1.00 CCTV & LCS/QWS Cabinets
AT-N-LAY-CABJ4-I 14 Red 223 1.00 CCTV & LCS/QWS Cabinets
AT-N-LAY-CABJ5 14 Red 223 1.00 CMS & LCS/QWS Cabinets
AT-N-LAY-CABJ5-I 14 Red 223 1.00 CMS & LCS/QWS Cabinets
AT-N-LAY-CABLE 7 White 0.30 Cables
AT-N-LAY-CABLE-D 7 White 0.30 Cables
AT-N-LAY-CABLE-T 7 White 0.30 Cables
AT-N-LAY-CABP 1 Red 0.20 Power Supply Cabinets
AT-N-LAY-CABP-I 1 Red 0.20 Power Supply Cabinets
AT-N-LAY-CABP1 6 Magenta 0.75 VDS Cabinet with Power Supply
AT-N-LAY-CABP1-I 6 Magenta 0.75 VDS Cabinet with Power Supply
AT-N-LAY-CABP2 4 Cyan 0.50 CCTV Cab. with Power Supply
AT-N-LAY-CABP2-I 4 Cyan 0.50 CCTV Cab. with Power Supply
AT-N-LAY-CABP3 30 Orange 5 0.60 CMS Cabinet with Power Supply

app1-advtraf Page 9 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-N-LAY-CABP3-I 30 Orange 5 0.60 CMS Cabinet with Power Supply
AT-N-LAY-CABP4 34 Orange 0.50 LCS/QWS Cabinet with Power Supply
AT-N-LAY-CABP4-I 34 Orange 0.50 LCS/QWS Cabinet with Power Supply
AT-N-LAY-CABPJ1 14 Red 223 1.00 RMS & VDS Cab. with Power Supply
AT-N-LAY-CABPJ1-I 14 Red 223 1.00 RMS & VDS Cab. with Power Supply
AT-N-LAY-CABPJ2 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power Supply
AT-N-LAY-CABPJ2-I 14 Red 223 1.00 LCS/QWS & VDS Cab. with Power Supply
AT-N-LAY-CABPJ3 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power Supply
AT-N-LAY-CABPJ3-I 14 Red 223 1.00 RMS & LCS/QWS & VDS Cab. with Power Supply
AT-N-LAY-CABPJ4 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power Supply
AT-N-LAY-CABPJ4-I 14 Red 223 1.00 CCTV & LCS/QWS Cab. with Power Supply
AT-N-LAY-CABPJ5 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power Supply
AT-N-LAY-CABPJ5-I 14 Red 223 1.00 CMS & LCS/QWS Cab. with Power Supply
AT-N-LAY-CABTS 7 White 0.30 Traffic Signal Controller Cabinet
AT-N-LAY-CAER 7 White 0.30 Cables
AT-N-LAY-CAER-D 7 White 0.30 Cables
AT-N-LAY-CAER-T 7 White 0.30 Cables
AT-N-LAY-CCTV 4 Cyan 0.50 CCTV Cameras
AT-N-LAY-CCTV-I 4 Cyan 0.50 CCTV Cameras
AT-N-LAY-CCTV-T 4 Cyan 0.50 CCTV Cameras
AT-N-LAY-COM1 7 White 0.30 Electrical Maintenance Holes
AT-N-LAY-COM1-D 7 White 0.30 Electrical Maintenance Holes
AT-N-LAY-COM1-I 7 White 0.30 Electrical Maintenance Holes
AT-N-LAY-COM2 7 White 0.30 Pedestals
AT-N-LAY-COM2-D 7 White 0.30 Pedestals
AT-N-LAY-COM2-I 7 White 0.30 Pedestals
AT-N-LAY-COM3 7 White 0.30 Junction Boxes
AT-N-LAY-COM3-D 7 White 0.30 Junction Boxes
AT-N-LAY-COM3-I 7 White 0.30 Junction Boxes
AT-N-LAY-COM4 7 White 0.30 Pull Boxes
AT-N-LAY-COM4-D 7 White 0.30 Pull Boxes
AT-N-LAY-COM4-I 7 White 0.30 Pull Boxes
AT-N-LAY-COM5 7 White 0.30 CB
AT-N-LAY-COM5-I 7 White 0.30 CB

app1-advtraf Page 10 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-N-LAY-CPAV 7 White 0.30 Cables
AT-N-LAY-CPAV-D 7 White 0.30 Cables
AT-N-LAY-CPAV-T 7 White 0.30 Cables
AT-N-LAY-DCEM 7 White 0.30 Ducts and/or cables
AT-N-LAY-DCEM-D 7 White 0.30 Ducts and/or cables
AT-N-LAY-DCEM-T 7 White 0.30 Ducts and/or cables
AT-N-LAY-DCSM 7 White 0.30 Ducts and/or cables
AT-N-LAY-DCSM-D 7 White 0.30 Ducts and/or cables
AT-N-LAY-DCSM-T 7 White 0.30 Ducts and/or cables
AT-N-LAY-DCUG 7 White 0.30 Ducts and/or cables
AT-N-LAY-DCUG-D 7 White 0.30 Ducts and/or cables
AT-N-LAY-DCUG-I 7 White 0.30 Ducts and/or cables
AT-N-LAY-DCUG-T 7 White 0.30 Ducts and/or cables
AT-N-LAY-DET1 6 Magenta 0.75 Detector Loops
AT-N-LAY-DET1-I 6 Magenta 0.75 Detector Loops
AT-N-LAY-MISC1 7 White 0.30 Guys
AT-N-LAY-PS1 1 Red 0.20 Power Supply Poles
AT-N-LAY-PS2 3 Green 0.40 Ground Rods
AT-N-LAY-PS3 1 Red 0.20 Subststions
AT-N-LAY-PS3-I 1 Red 0.20 Subststions
AT-N-LAY-SIGN1 30 Orange 5 0.60 CMS Signs
AT-N-LAY-SIGN1-I 30 Orange 5 0.60 CMS Signs
AT-N-LAY-SIGN2 34 Orange 0.50 LCS/QWS Signs
AT-N-LAY-SIGN2-I 34 Orange 0.50 LCS/QWS Signs
AT-N-LAY-SIGN4 7 White 0.30 Blank Out Signs
AT-N-LAY-SIGN4-I 7 White 0.30 Blank Out Signs
AT-N-LAY-SUPP1 30 Orange 5 0.60 CMS Overhead Structures
AT-N-LAY-SUPP2 30 Orange 5 0.60 CMS footings.
AT-N-LAY-SUPP2-D 30 Orange 5 0.60 CMS footings.
AT-N-LAY-SUPP3 34 Orange 0.50 LCS/QWS Overhead Structures
AT-N-LAY-SUPP4 34 Orange 0.50 LCS/QWS Footings
AT-N-LAY-SUPP4-D 34 Orange 0.50 LCS/QWS Footings
AT-N-LAY-SUPP6 4 Cyan 0.50 CCTV Poles
AT-N-LAY-SUPP7 7 White 0.30 Concrete Pads.

app1-advtraf Page 11 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-N-LAY-SUPP7-D 7 White 0.30 Concrete Pads.
===============
New Wiring
===============
AT-N-WIR-CABLE 7 White 0.30 Cables
AT-N-WIR-CABLE-T 7 White 0.30 Cables
AT-N-WIR-CAER 7 White 0.30 Cables
AT-N-WIR-CAER-T 7 White 0.30 Cables
AT-N-WIR-CCTV 4 Cyan 0.50 CCTV Cameras
AT-N-WIR-CCTV-I 4 Cyan 0.50 CCTV Cameras
AT-N-WIR-COM1 7 White 0.30 Electrical Maintenance Holes
AT-N-WIR-COM1-I 7 White 0.30 Electrical Maintenance Holes
AT-N-WIR-COM2 7 White 0.30 Pedestals
AT-N-WIR-COM2-I 7 White 0.30 Pedestals
AT-N-WIR-COM3 7 White 0.30 Junction Boxes
AT-N-WIR-COM3-I 7 White 0.30 Junction Boxes
AT-N-WIR-COM4 7 White 0.30 Pull Boxes
AT-N-WIR-COM4-I 7 White 0.30 Pull Boxes
AT-N-WIR-COM5 7 White 0.30 CB
AT-N-WIR-COM5-I 7 White 0.30 CB
AT-N-WIR-CPAV 7 White 0.30 Cables
AT-N-WIR-CPAV-T 7 White 0.30 Cables
AT-N-WIR-DCEM 7 White 0.30 Ducts and/or cables
AT-N-WIR-DCEM-T 7 White 0.30 Ducts and/or cables
AT-N-WIR-DCSM 7 White 0.30 Ducts and/or cables
AT-N-WIR-DCSM-T 7 White 0.30 Ducts and/or cables
AT-N-WIR-DCUG 7 White 0.30 Ducts and/or cables
AT-N-WIR-DCUG-I 7 White 0.30 Ducts and/or cables
AT-N-WIR-DCUG-T 7 White 0.30 Ducts and/or cables
AT-N-WIR-DET1 6 Magenta 0.75 Detector Loops
AT-N-WIR-DET1-I 6 Magenta 0.75 Detector Loops
AT-N-WIR-PS2 3 Green 0.40 Ground Rods
AT-N-WIR-PS3 1 Red 0.20 Subststions

app1-advtraf Page 12 of 13
Pen
Full-Tone Plotting Thickness
Layer LineStyle Color# Color Color# (mm) Description
AT-N-WIR-PS3-I 1 Red 0.20 Subststions
AT-N-WIR-SIGN1 30 Orange 5 0.60 CMS Signs
AT-N-WIR-SIGN1-I 30 Orange 5 0.60 CMS Signs
AT-N-WIR-SIGN2 34 Orange 0.50 LCS/QWS Signs
AT-N-WIR-SIGN2-I 34 Orange 0.50 LCS/QWS Signs
AT-N-WIR-SIGN4 7 White 0.30 Blank Out Signs
AT-N-WIR-SIGN4-I 7 White 0.30 Blank Out Signs

app1-advtraf Page 13 of 13
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-2

LAYER STANDARDS

For

ELECTRICAL DESIGN DRAWINGS


ELECTRICAL DESIGN LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC-D )

Discipline (AA): The following abbreviations are used:


EL - Electrical

Status (B): The following abbreviations are used:


G - General (non-feature specific)
E - Existing Plan
F - Future
N - New Contstruction
R - Removals

Feature (CCC-CC): The feature portion of the layer name is defined as follows:
For example: EL-N-CTRLCAB

Annotation (D): The annotation portion is generally applied at the "feature" level.
For example: EL-E-DET-T

NOTES:
1) * Design Line - please refer to OPSD 2001.010 for the appropriate line patterning
2) Templates are distributed with this manual
3) Symbols are included in the menu (refer to OPSD 2001 for symbol definitions)

app2-electrical Page 1 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
=============
General Layers
=============
BORDER CONTINUOUS 6 Magenta 135 0.75 Border - Frame - Title Block
DWGINFO CONTINUOUS 7 White 9 NO PLOT Drawing Info
VPORTS CONTINUOUS 4 Cyan 8 NO PLOT View Ports
EL-G-25MM CONTINUOUS 22 Red shade 254 0.25 General Line 0.25mm
EL-G-40MM CONTINUOUS 63 Light yellow 253 0.40 General Line 0.40mm
EL-G-50MM CONTINUOUS 4 Cyan 8 0.50 General Line 0.50mm
EL-G-75MM CONTINUOUS 6 Magenta 135 0.75 General Line 0.75mm
EL-G-25MM-CL1 CL1 22 Red shade 254 0.25 General CL1
EL-G-25MM-CL2 CL2 22 Red shade 254 0.25 General CL2
EL-G-25MM-DL1 DL1 92 Green shade 254 0.25 General DL1
EL-G-25MM-DL2 DL2 132 Cyan shade 254 0.25 General DL2
EL-G-40MM-DL3 DL3 63 Light yellow 253 0.40 General DL3
EL-G-50MM-DL4 DL4 134 Light blue 8 0.50 General DL4
EL-G-50MM-DL5 DL5 4 Cyan 8 0.50 General DL5
EL-G-CONS CONTINUOUS 8 Gray 8 NO PLOT Construction (working) Line
EL-G-DIM CONTINUOUS 132 Cyan 254 0.25 General Dimensions
EL-G-HATCH CONTINUOUS 1 Red 251 0.20 General Hatch Pattern
EL-G-TEXT TEXT 3 White 9 varies General Text
=============
Existing Conditions
=============
EL-E-CTRLCAB SYMBOL 80 Light green 9 0.30 T.S. Controller Cabinet

T.S. Controller Cabinet with Adjacent Power Supply


T.S. Controller Cabinet with E.C.I.B
T.S. Controller Cabinet Pad or Base Mounted
EL-E-CTRLCAB-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-CTRLCAB-IDC SYMBOL 80 Light yellow 9 0.30 Identification Code
EL-E-CTRLCAB-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 2 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
EL-E-DET SYMBOL 80 Light green 9 0.30 Simple Loop
Duplex Loop
Powerhead Loop
Diamond Loop
Probe Vehicle Detector
Microwave - Lightwave - Sonic Vehicle Detector
Pedestrian Pushbutton
EL-E-DET-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-DET-IDC SYMBOL 80 Light green 9 0.30 Identification Code
EL-E-DET-T TEXT25 7 White 9 0.30 Text Size 2.5mm
Existing Ducts/Cables To Remain In Place,
EL-E-DUCT *CONTINUOUS 3 Green 9 0.40 *continuous line with labels
EL-E-DUCT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-DUCT-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-E-FOOT SYMBOL 80 Light green 9 0.30 Concrete Pad/Footing In Earth Or Rock
Footing in Structure
Sign Footing
EL-E-FOOT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-FOOT-IDC SYMBOL 80 Light green 9 0.30 Identification Code
EL-E-FOOT-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-E-GUY SYMBOL 80 Brown 9 0.30 Simple Guy With Single Anchor
Double Guy With Single Anchor
Double Guy With Double Anchor

Single Guy With Sidewalk Strut and Single Anchor


EL-E-GUY-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-GUY-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-E-LUM SYMBOL 80 Light green 9 0.30 Luminaires
Luminaires With Bracket
Floodlight Luminaires
Underpass or Surface Mounted Luminaires
Obstruction or Navigation Luminaires

app2-electrical Page 3 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
EL-E-LUM-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-LUM-IDC SYMBOL 80 Light green 9 0.30 Identification Code
EL-E-LUM-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-E-MH CONTINUOUS 80 Light green 9 0.30 Electrical Maintenance Holes
Junction Box (Embedded or Surface Mounted)
Handhole - Underground
EL-E-MH-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-MH-IDC SYMBOL 80 Light green 9 0.30 Identification Code
EL-E-MH-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-E-POLE CONTINUOUS 80 Light green 9 0.30 Poles
EL-E-POLE-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-POLE-IDC SYMBOL 80 Light green 9 0.30 Identification Code
EL-E-POLE-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-E-PWRSUPP SYMBOL 80 Light green 254 0.30 Power supply equipment
Transformer
Generator
Pse - pad and/or base mounted
Photoelectric controller
EL-E-PWRSUPP-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-PWRSUPP-IDC SYMBOL 80 Light green 9 0.30 Identification Code
EL-E-PWRSUPP-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-E-TSDEV SYMBOL 80 Light green 9 0.30 Illuminated Traffic Sign - Single Side
Illuminated Traffic Sign - Double Side
Illuminated Traffic Sign with Flasher Beacon
Flasher Beacon
Flasher Mechanism
Traffic Sign - Overhead with Static Sign
Traffic Sign - Overhead with Changeable Message
Sign
Traffic Sign - Overhead With Lane Control Signs
EL-E-TSDEV-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-TSDEV-IDC SYMBOL 80 Light green 9 0.30 Identification Code
EL-E-TSDEV-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 4 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
EL-E-TSHEAD SYMBOL 80 Light green 0.30 Highway Signal Head - 300mm Red 200mm Amber
9 and Green Lenses With Backboard
Highway Signal Head - All 300mm Lenses with
backboard
Standard signal head - all 200mm lenses
Standard signal head - all 200mm lenses with
backboard
Special signal heads with backboard
Pedestrian signal head - two section type
Pedestrian signal head - single section fibre optic
type
Signal head with backboard - span wire mounting
Signal heads with backboard and mast arm
Signal head with backboard and double arm
bracket
EL-E-TSHEAD-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-E-TSHEAD-T TEXT25 7 White 9 0.30 Text Size 2.5mm
=============
Future Conditions
=============
EL-F-DET DL1 22 Light red 254 0.25 Simple Loop
Duplex Loop
Powerhead Loop
Diamond Loop
Probe Vehicle Detector
Microwave - Lightwave - Sonic Vehicle Detector
Pedestrian Pushbutton
EL-F-DET-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-F-DET-IDC SYMBOL 20 Light red 9 0.30 Identification Code
EL-F-DET-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-F-DUCT DL15 63 Light yellow 253 0.40 Spare ducts for future use
EL-F-DUCT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-F-DUCT-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-F-CBLE-SLOT DL13 63 Light yellow 253 0.40 Cables - In Pavement Slot
EL-F-CBLE-SLOT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-F-CBLE-SLOT-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-F-FOOT DL1 22 Light red 254 0.25 Concrete Pad/Footing In Earth Or Rock
Footing in Structure
Sign Footing
EL-F-FOOT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-F-FOOT-IDC SYMBOL 20 Light red 9 0.30 Identification Code
app2-electrical Page 5 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
EL-F-FOOT-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-F-MH DL1 22 Light red 254 0.25 Electrical Maintenance Holes
Junction box - embedded or surface mounted
Handhole underground

app2-electrical Page 6 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
EL-F-MH-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-F-MH-IDC SYMBOL 20 Light red 9 0.30 Identification Code
EL-F-MH-T TEXT25 7 White 9 0.30 Text Size 2.5mm
=============
New Construction
=============
EL-N-CBLE-AERL DL14 4 Cyan 8 0.50 Cables - Aerial
EL-N-CBLE-AERL-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-CBLE-AERL-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-CBLE-DB DL4 64 Light blue 8 0.50 Cable Direct Buried
EL-N-CBLE-DB-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-CBLE-DB-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-CBLE-EXDT DL10 92 Green shade 134 0.25 Cables - Installed In Existing Ducts
EL-N-CBLE-EXDT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-CBLE-EXDT-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-CBLE-SLOT DL13 4 Cyan 8 0.50 Cables - In Pavement Slot
EL-N-CBLE-SLOT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-CBLE-SLOT-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-CBLE-SPLC CONTINUOUS 50 Light yellow 9 0.30 In Line Cable Splice
Tap Cable Splice
Wiring Enclosure
Equipment Items
EL-N-CBLE-SPLC-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-CBLE-SPLC-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-CBLE-SPLC-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-DUCT-EMBD DL11 92 Green shade 134 1.00 Ducts - Embedded.
EL-N-DUCT-EMBD-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-DUCT-EMBD-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-DUCT-SMTD DL12 63 Light yellow 134 1.00 Ducts - Surface Mounted.
EL-N-DUCT-SMTD-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-DUCT-SMTD-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-DUCT-UGD CONTINUOUS 4 Cyan 134 1.00 Ducts - Underground
EL-N-CBR CONTINUOUS 21 Red shade 251 0.25 Cable Bricks

app2-electrical Page 7 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
EL-N-DUCT-UGD-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-DUCT-UGD-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code or Reference Point
EL-N-DUCT-UGD-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-DUCT CONTINUOUS 4 Cyan 8 0.50 Ducts And/Or Cables
EL-N-DUCT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-DUCT-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-DUCT-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-COMM SYMBOL 50 Light yellow 9 0.30 Communications Pedestal with IDC
Coaxial Cable Power Supply with IDC
Coaxial Cable Amplifier, AGC with IDC
Coaxial Cable Amplifier, MGC with IDC
Coaxial Cable Amplifier,AGC & MGC with IDC
Temporarily ,all symbols for Advance Traffic
Management System
EL-N-COMM-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-COMM-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-COMM-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-CTRLCAB SYMBOL 50 Light yellow 9 0.30 Controller Cabinet
Controller cabinet with adjacent power supply
Controller cabinet with E.C.I.B
EL-N-CTRLCAB-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-CTRLCAB-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-CTRLCAB-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-DET SYMBOL 50 Light yellow 9 0.30 Simple Loop
Duplex loop
Powerhead loop
Diamond loop
Probe vehicle detector
Microwave - lightwave - sonic vehicle detector
Pedestrian pushbutton
EL-N-DET-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-DET-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-DET-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 8 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
EL-N-FOOT SYMBOL 50 Light yellow 9 0.30 Concrete Pad/Footing In Earth Or Rock
Footing in structure
Sign footing
EL-N-FOOT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-FOOT-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-FOOT-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-GRND SYMBOL 50 Light yellow 9 0.30 Ground Rods
Ground Electrodes
EL-N-GRND-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-GRND-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-GUY SYMBOL 50 Light yellow 9 0.30 Simple Guy With Single Anchor
Double guy with single anchor
Double guy with double anchor
Single guy with sidewalk strut and single anchor
EL-N-GUY-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-GUY-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-LUM SYMBOL 50 Light Yellow 9 0.30 Luminaires
Luminaires With Bracket
Floodlight Luminaires
Underpass or Surface Mounted Luminaires

Luminaires (Number Shown Indicates Luminaire


Location on High Mast with Respect to Pole Handle)
Obstruction or Navigation Luminaires
EL-N-LUM-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-LUM-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-LUM-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-MH SYMBOL 50 Light yellow 9 0.30 Electrical Maintenance Holes
Junction box - embedded or surface mounted
Handhole underground
EL-N-MH DL1 50 Light yellow 9 0.30 Electrical Maintenance Holes
Junction box - embedded or surface mounted
Handhole underground

app2-electrical Page 9 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
EL-N-MH-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-MH-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-MH-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-POLE SYMBOL 50 Light yellow 9 0.30 Poles
EL-N-POLE DL1 50 Light yellow 9 0.30 Poles
EL-N-POLE-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-POLE-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code For Poles
EL-N-POLE-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-PWRSUPP SYMBOL 50 Light yellow 9 0.30 Power Supply Equipment
Transformer
Generator
Photoelectric controller
PSE - pad and/or base mounted
EL-N-PWRSUPP-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-PWRSUPP-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-PWRSUPP-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-TSDEV SYMBOL 50 Light yellow 9 0.30 Illuminated Traffic Sign - Single Side
Illuminated Traffic Sign - Double Side
Illuminated traffic sign with flasher beacon
Flasher beacon
Flasher beacon (4-way)
Flasher mechanism

Traffic sign - overhead sign support with static sign


Traffic sign - overhead sign support with
changeable message sign
Traffic sign - overhead sign support with lane
control signs
EL-N-TSDEV-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-TSDEV-IDC SYMBOL 50 Light yellow 9 0.30 Identification Code
EL-N-TSDEV-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 10 of 11
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
EL-N-TSHEAD SYMBOL 50 Light yellow 9 0.30 Highway Signal Heads
Special signal heads with backboard
Pedestrian signal heads
Signal head with backboard - span wire mounting
Signal heads with backboard and mast arm
TS Arms & Bracket
EL-N-TSHEAD-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-N-TSHEAD-IDC SYMBOL 50 Light Yellow 9 0.30 Identification Code
EL-N-TSHEAD-T TEXT25 7 White 9 0.30 Text Size 2.5mm
EL-N-LIMIT CONTINUOUS 6 Magenta 135 0.75 Electrical Work Limit
===================
Removals
===================
Existing Ducts And/Or Cables To Be Removed,
EL-R-CBLE-RMVL *CONTINUOUS 63 Light yellow 9 0.40 *continuous line with labels
Existing Ducts and/or Cables to be Abandoned,
EL-R-CBLE-ABND *CONTINUOUS 63 Light yellow 9 0.40 *continuous line with labels
EL-R-EQPT SYMBOL 130 Cyan shade 9 0.30 Symbol for removal, symbol for abandon
EL-R-EQPT-D CONTINUOUS 132 Cyan shade 254 0.25 Dimensions
EL-R-EQPT-IDC SYMBOL 130 Light yellow 9 0.30 Identification Code
EL-R-EQPT-T TEXT25 7 White 9 0.30 Text Size 2.5mm

app2-electrical Page 11 of 11
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-3

LAYER STANDARDS

For

ENVIRONMENTAL DRAWINGS
ENVIRONMENTAL LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC-D )

Discipline (AA): The following abbreviations are used:


EN - Environmental

Status (B): The following abbreviations are used:


N - New Construction

Feature (CCC-CC): The feature portion of the layer name is defined by 2 components.
- the 1st portion indentifies a feature group
- the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:


BAR - Barriers GND - Ground
DRN - Drainage UTL - Utilties
FSH - Fish Related VEG - Vegetation

Annotation (D): The annotation portion is generally applied at the "feature" level.
For example: EN-N-GND-CP-P

* NOTE: Drawing details for layers marked with "*" will be provided in the Fisheries Technical Manual. Part II, available in 1997

app3-environ Page 1 of 4
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Barrier Layers
==============
EN-N-BAR-BERM Symbol 7 White 4 1 Berm Barrier
EN-N-BAR-HDSB Symbol 2 Yellow 4 1 Heavy Duty Straw Bale Barrier
EN-N-BAR-HDSF Symbol 6 Magenta 4 1 Heavy Duty Silt Fence Barrier
EN-N-BAR-LDSB Symbol 7 Yellow 7 0 Light Duty Straw Bale Barrier
EN-N-BAR-LDSF Symbol 6 Magenta 7 0 Light Duty Silt Fence Barrier
EN-N-BAR-SAND Symbol 5 Blue 4 1 Sandbag Barrier
==============
Drainage Layers
==============
EN-N-DRN-BVB Continuous 1 Red 7 0 Beaver Baffler
EN-N-DRN-CHUT Continuous 5 Blue 4 1 Chute
EN-N-DRN-DDP Continuous 2 Yellow 5 1 Dry Detention Pond
EN-N-DRN-DWT Continuous 3 Green 5 1 Dewatering Trap
EN-N-DRN-FCRC Symbol 1 Red 4 1 Temporary Rock Flow Check, Flat Bottom
or Channel
EN-N-DRN-FCRV Symbol 1 Red 4 1 Temporary Rock Flow Check, V Ditch
EN-N-DRN-FCSB Symbol 5 Blue 4 1 Sandbag Flow Check
EN-N-DRN-FCSF Symbol 6 Magenta 4 1 Silt Fence Flow Check
EN-N-DRN-FCSW Symbol 2 Yellow 4 1 Straw Bale Flow Check
EN-N-DRN-GSF Continuous 4 Cyan 7 0 Groundwater Spring Feed
EN-N-DRN-GWF Continuous 5 Blue 7 0 Groundwater Well Feed
EN-N-DRN-INB Continuous 3 Green 4 1 Infiltration Basin
EN-N-DRN-INT Continuous Orange 4 1 Infiltration Trench
EN-N-DRN-TRCR Continuous Orange 5 1 Turbidity Curtain
EN-N-DRN-WDP Continuous 5 Blue 5 1 Wet Detention Pond
EN-N-DRN-WET Symbol 4 Cyan 4 1 Wetland
EN-N-DRN-XST Symbol Orange 4 1 Excavated Sediment Trap

app3-environ Page 2 of 4
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Fish Related Layers
==============
EN-N-FSH-AREF* Continuous Artificial Reefs
EN-N-FSH-ASPS* Continuous Artificial Spawning Shoals
EN-N-FSH-BLP* Continuous Blast Pools
EN-N-FSH-BPS* Symbol Boulder Placement in Streams
EN-N-FSH-BSS* Continuous Bass Spawning Box
EN-N-FSH-CHBD* Continuous Beaded Channel
EN-N-FSH-FW* Continuous Fishways
EN-N-FSH-GCD* Continuous Gravel Catchment Devices
EN-N-FSH-GRYN* Continuous Groynes
EN-N-FSH-LGCS* Continuous Log Crib Stuctures
EN-N-FSH-LJDC* Symbol Log Jam Structure and Debris Collector
EN-N-FSH-MGB* Continuous Migration Barrier
EN-N-FSH-PACV* Symbol Pallet Cover Structures
EN-N-FSH-RFB* Continuous Riffle Building
EN-N-FSH-RIPL* Continuous Log Rip-Rap
EN-N-FSH-RIPR* Continuous Rock Rip-Rap
EN-N-FSH-SCLG* Continuous Scour Logs
EN-N-FSH-SLBC* Symbol Submerged Log Bank Cover
EN-N-FSH-SPB* Continuous Spawning Bed
EN-N-FSH-TBS* Symbol Tree and Brush Shelters
EN-N-FSH-WGD* Continuous Wing Deflectors
==============
Ground Layers
==============
EN-N-GND-CP-P Continuous 6 Magenta 4 1 Contaminated Property
EN-N-GND-EXM-P Continuous 1 Red 4 1 Excess Materials

app3-environ Page 3 of 4
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Utilities Layers
==============
EN-N-UTL-SPT Continuous Orange 7 0 Septic Tanks
EN-N-UTL-WAWE Continuous 4 Cyan 7 0 Water Wells
==============
Vegetation Layers
==============
EN-N-VEG-AAVG* Symbol Artificial Aquatic Vegetation
EN-N-VEG-AVG* Symbol Aquatic Vegetation
EN-N-VEG-CNT Symbol 1 Red 5 1 Coniferous Trees
EN-N-VEG-CRF-P Hatch Pattern 1 Red 4 1 Coniferous Reforestation
EN-N-VEG-DRF-P Hatch Pattern 3 Green 4 1 Deciduous Reforestation
EN-N-VEG-DTR Symbol 3 Green 5 1 Deciduous Trees
EN-N-VEG-ECB-P Hatch Pattern 1 Red 7 0 Erosion Control Blanket
EN-N-VEG-MRF-P Hatch Pattern 4 Cyan 4 1 Mixed Reforestation
EN-N-VEG-SHR Symbol 2 Yellow 4 1 Shrubs
EN-N-VEG-SHRB-P Hatch Pattern 2 Yellow 4 1 Shrub Bed
EN-N-VEG-SM1-P Hatch Pattern 3 Green 7 0 Seeding and Mulching Type 1
EN-N-VEG-SM2-P Hatch Pattern 6 Magenta 7 0 Seeding and Mulching Type 2
EN-N-VEG-SM3-P Hatch Pattern 2 Yellow 7 0 Seeding and Mulching Type 3

app3-environ Page 4 of 4
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-4

LAYER STANDARDS

For

FOUNDATION DRAWINGS
FOUNDATION DESIGN LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC-D )

Discipline (AA): The following abbreviations are used:


FD - Foundation Design

Status (B): The following abbreviations are used:


E - Existing Conditions

Feature (CCC-CC): The feature portion of the layer name is defined by a single component

Annotation (D): The annotation portion is applied at the "feature" level.


For example: FD-E-DESC1-T

app4-foundations Page 1 of 2
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
FD-E-BASE100-T SYMBOL 130 Cyan 2 0.25 Sheet scale = 100'
FD-E-BASE50-T SYMBOL 130 Cyan 2 0.25 Sheet scale = 50'
FD-E-CHART_FRAME SYMBOL 7 White 2 0.25 Sheet border
FD-E-CHART_TEXT-T CONTINUOUS 130 Cyan 2 0.25 Sheet text
FD-E-CONEPLOT1 SYMBOL 3 Green 2 0.25 Cone graph on p.1
FD-E-CONEPLOT2 SYMBOL 3 Green 2 0.25 Cone graph on p.2
FD-E-CONEPLOT3 SYMBOL 3 Green 2 0.25 Cone graph on p.3
FD-E-CONEPLOT4 SYMBOL 3 Green 2 0.25 Cone graph on p.4
FD-E-CONEPLOT5 SYMBOL 3 Green 2 0.25 Cone graph on p.5
FD-E-DESC1-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.1
FD-E-DESC2-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.2
FD-E-DESC3-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.3
FD-E-DESC4-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.4
FD-E-DESC5-T CONTINUOUS 2 Yellow 2 0.25 Description text on p.5
FD-E-ELEVSCAL1 SYMBOL 130 Cyan 2 0.25 Elevation text on p.1
FD-E-ELEVSCAL2 SYMBOL 130 Cyan 2 0.25 Elevation text on p.2
FD-E-ELEVSCAL3 SYMBOL 130 Cyan 2 0.25 Elevation text on p.3
FD-E-ELEVSCAL4 SYMBOL 130 Cyan 2 0.25 Elevation text on p.4
FD-E-ELEVSCAL5 SYMBOL 130 Cyan 2 0.25 Elevation text on p.5
FD-E-GNDWATER1 SYMBOL 6 Magenta 2 0.25 Ground water on p.1
FD-E-GNDWATER2 SYMBOL 6 Magenta 2 0.25 Ground water on p.2
FD-E-GNDWATER3 SYMBOL 6 Magenta 2 0.25 Ground water on p.3
FD-E-GNDWATER4 SYMBOL 6 Magenta 2 0.25 Ground water on p.4
FD-E-GNDWATER5 SYMBOL 6 Magenta 2 0.25 Ground water on p.5
FD-E-LOGO SYMBOL 7 White 2 0.25 MTO logo
FD-E-SAMPLES1 SYMBOL 2 Yellow 2 0.25 Soil samples on p.1
FD-E-SAMPLES2 SYMBOL 2 Yellow 2 0.25 Soil samples on p.2
FD-E-SAMPLES3 SYMBOL 2 Yellow 2 0.25 Soil samples on p.3
FD-E-SAMPLES4 SYMBOL 2 Yellow 2 0.25 Soil samples on p.4
FD-E-SAMPLES5 SYMBOL 2 Yellow 2 0.25 Soil samples on p.5
FD-E-VANES1 SYMBOL 2 Yellow 2 0.25 Vanes on p.1
FD-E-VANES2 SYMBOL 2 Yellow 2 0.25 Vanes on p.2
FD-E-VANES3 SYMBOL 2 Yellow 2 0.25 Vanes on p.3
FD-E-VANES4 SYMBOL 2 Yellow 2 0.25 Vanes on p.4
FD-E-VANES5 SYMBOL 2 Yellow 2 0.25 Vanes on p.5

app4-foundations Page 2 of 2
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-5

LAYER STANDARDS

For

GEOTECHNICAL DRAWINGS
GEOTECHNICAL LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC )

Discipline (AA): The following abbreviations are used:


GE - Geotechnical

Status (B): The following abbreviations are used:


N - New Construction

Feature (CCC-CC):The feature portion of the layer name is defined by 3 components.


- the 1st portion indentifies a drawing type
- the 2nd portion indentifies a feature group
- the 3rd portion identifies the feature

The following "drawing type" abbreviations are used:


MAP - Drawing Frame and Title Block Info
PIT - Pit Sketch
TYP - Typical

The following "feature-group" abbreviations are used:


BASE - Base Material SUB - Sub Base
BIN - Binder Courses SUBQ - Sub-surface Materials
ERTH - Earth SURF - Surface Materials
MISC - Miscellaneous SYM - Symbol

app5-geotech Page 1 of 5
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Map Layers
==============
GE-N-MAP-SYM-CONT SYMBOL 7 White 6 0.75 Contract number
GE-N-MAP-SYM-NTH SYMBOL 7 White 6 0.75 North arrow symbol
GE-N-MAP-SYM-SCE SYMBOL 3 Green 7 0.30 Symbol for source position
GE-N-MAP-SYM-WP SYMBOL 7 White 6 0.75 Work project number
GE-N-MAP-TEXT-GRID CONTINUOUS 6 Magenta 5 0.60 Title grid text
GE-N-MAP-TEXT-TLE CONTINUOUS 7 White 6 0.75 Title block text
==============
Pit Layers
==============
GE-N-PIT-SYM-AUG SYMBOL 1 Red 1 0.20 Symbol for borehole
GE-N-PIT-SYM-BAC SYMBOL 2 Yellow 2 0.25 Test Pit Dug by Backhoe
GE-N-PIT-SYM-BED SYMBOL 3 Green 7 0.30 Symbol for bed rock
GE-N-PIT-SYM-BLG SYMBOL 1 Red 1 0.20 Symbol for building
GE-N-PIT-SYM-BUS SYMBOL 3 Green 7 0.30 Symbol for bush
GE-N-PIT-SYM-CON SYMBOL 1 Red 1 0.20 Symbol for coniferous
GE-N-PIT-SYM-DEC SYMBOL 1 Red 1 0.20 Symbol for deciduous
GE-N-PIT-SYM-FAC SYMBOL 1 Red 1 0.20 Symbol for pit face
GE-N-PIT-SYM-FEN SYMBOL 1 Red 1 0.20 Symbol for fence line
GE-N-PIT-SYM-HL SYMBOL 1 Red 1 0.20 Symbol for power line
GE-N-PIT-SYM-HWY SYMBOL 3 Green 3 0.20 Symbol for highway
GE-N-PIT-SYM-MAR SYMBOL 1 Red 1 0.20 Symbol for marsh
GE-N-PIT-SYM-OUT SYMBOL 1 Red 1 0.20 Symbol for pit outline
GE-N-PIT-SYM-PIP SYMBOL 1 Red 1 0.20 Symbol for pipeline
GE-N-PIT-SYM-RIV SYMBOL 4 Cyan 3 0.40 Symbol for river
GE-N-PIT-SYM-RR SYMBOL 1 Red 1 0.20 Symbol for rail road
GE-N-PIT-SYM-SLO SYMBOL 3 Green 7 0.3 Symbol for slope
GE-N-PIT-SYM-STR SYMBOL 1 Red 1 0.20 Symbol for structure
GE-N-PIT-SYM-TEL SYMBOL 1 Red 1 0.20 Symbol for telephone line
GE-N-PIT-SYM-TWP SYMBOL 1 Red 1 0.20 Symbol for township rd

app5-geotech Page 2 of 5
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
GE-N-PIT-TEXT-GRID CONTINUOUS 6 Magenta 5 0.60 Title grid text
GE-N-PIT-TEXT-TLE CONTINUOUS 7 White 6 0.75 Title block text
==============
Typical Layers
==============
GE-N-TYP-BASE-AT CONTINUOUS 1 Red 1 0.2 Asphalt Treated Base
GE-N-TYP-BASE-CT CONTINUOUS 1 Red 1 0.20 Cement treated base
GE-N-TYP-BASE-GRAN CONTINUOUS 1 Red 1 0.20 Granular "A" Base
GE-N-TYP-BASE-GRO CONTINUOUS 1 Red 1 0.20 Granular "O"
GE-N-TYP-BASE-OGD CONTINUOUS 1 Red 1 0.20 Open graded drainage layer
GE-N-TYP-BASE-PCC CONTINUOUS 1 Red 1 0.20 Portland Concrete Base
GE-N-TYP-BIN-HDB CONTINUOUS 3 Green 7 0.30 Heavy duty binder course
GE-N-TYP-BIN-HL2 CONTINUOUS 3 Green 7 0.3 HL-2 binder course
GE-N-TYP-BIN-HL3 CONTINUOUS 3 Green 7 0.3 HL-3 binder course
GE-N-TYP-BIN-HL4 CONTINUOUS 3 Green 7 0.3 HL-4 binder course
GE-N-TYP-BIN-HL8 CONTINUOUS 3 Green 7 0.3 HL-8 binder course
GE-N-TYP-BIN-MDB CONTINUOUS 3 Green 7 0.3 Medium Duty Binder Course
GE-N-TYP-BIN-RHM CONTINUOUS 3 Green 7 0.3 Recycled Binder Course
GE-N-TYP-ERTH-CUT CONTINUOUS 1 Red 1 0.2 Earth Cut
GE-N-TYP-ERTH-FIL CONTINUOUS 1 Red 1 0.2 Earth Fill
GE-N-TYP-MISC-BT CONTINUOUS 1 Red 1 0.20 Bituthene tape
GE-N-TYP-MISC-CB CONTINUOUS 1 Red 1 0.2 Catch Basin
GE-N-TYP-MISC-CG CONTINUOUS 1 Red 1 0.20 Curb and gutter
GE-N-TYP-MISC-DB CONTINUOUS 1 Red 1 0.20 Dowel bar
GE-N-TYP-MISC-GEO CONTINUOUS 1 Red 1 0.20 Geotextile
GE-N-TYP-MISC-GR CONTINUOUS 1 Red 1 0.20 Guide rail
GE-N-TYP-MISC-JT CONTINUOUS 3 Green 7 0.30 Joint
GE-N-TYP-MISC-LTD CONTINUOUS 1 Red 1 0.20 Load transfer device
GE-N-TYP-MISC-MH CONTINUOUS 1 Red 1 0.20 Manhole
GE-N-TYP-MISC-MIL CONTINUOUS 1 Red 1 0.20 Mill/coldplane
GE-N-TYP-MISC-RIP CONTINUOUS 1 Red 1 0.2 Rip-rap
GE-N-TYP-MISC-R&F CONTINUOUS 3 Green 7 0.3 Rout and Fill

app5-geotech Page 3 of 5
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
GE-N-TYP-MISC-R&S CONTINUOUS 3 Green 7 0.3 Rout and Seal
GE-N-TYP-MISC-SEW CONTINUOUS 1 Red 1 0.20 Sewer
GE-N-TYP-MISC-SOD CONTINUOUS 1 Red 1 0.20 Sod
GE-N-TYP-MISC-SUB CONTINUOUS 3 Green 7 0.3 Sub Drain
GE-N-TYP-MISC-TAC CONTINUOUS 3 Green 7 0.30 Tack coat
GE-N-TYP-MISC-TIE CONTINUOUS 1 Red 1 0.20 Tie bar
GE-N-TYP-MISC-TPS CONTINUOUS 1 Red 1 0.20 Topsoil
GE-N-TYP-SUB-CLR CONTINUOUS 1 Red 1 0.20 Clear stone
GE-N-TYP-SUB-GRA CONTINUOUS 1 Red 1 0.20 Granular"A" subbase
GE-N-TYP-SUB-GRB CONTINUOUS 1 Red 1 0.20 Granular"B" subbase
GE-N-TYP-SUB-SSM CONTINUOUS 1 Red 1 0.20 Select subgrade material
GE-N-TYP-SUBQ-ERTH CONTINUOUS 1 Red 1 0.2 Earth Subgrade
GE-N-TYP-SUBQ-MUS CONTINUOUS 1 Red 1 0.20 Muskeg
GE-N-TYP-SUBQ-ORG CONTINUOUS 1 Red 1 0.20 Organics
GE-N-TYP-SUBQ-RK CONTINUOUS 1 Red 1 0.2 Rock Subgrade
GE-N-TYP-SUBQ-RK-CUTCONTINUOUS 1 Red 1 0.2 Rock Cut
GE-N-TYP-SUBQ-RK-FILLCONTINUOUS 1 Red 1 0.2 Rock Fill
GE-N-TYP-SUBQ-STR CONTINUOUS 1 Red 1 0.2 Rock Shatter
GE-N-TYP-SUBQ-SWP CONTINUOUS 1 Red 1 0.20 Swamp
GE-N-TYP-SUBQ-WAT CONTINUOUS 4 Cyan 3 0.40 Water
GE-N-TYP-SURF-CIP CONTINUOUS 3 Green 7 0.30 Cold in place resurfacing
GE-N-TYP-SURF-DFC CONTINUOUS 3 Green 7 0.30 DFC surface course
GE-N-TYP-SURF-GRA CONTINUOUS 1 Red 1 0.20 Granular "A" surface
GE-N-TYP-SURF-HIP CONTINUOUS 3 Green 7 0.30 Hot in place resurfacing
GE-N-TYP-SURF-HL1 CONTINUOUS 3 Green 7 0.30 HL1 surface course
GE-N-TYP-SURF-HL3 CONTINUOUS 3 Green 7 0.30 HL3 surface course
GE-N-TYP-SURF-HL4 CONTINUOUS 3 Green 7 0.30 HL4 surface course
GE-N-TYP-SURF-MIC CONTINUOUS 3 Green 7 0.30 Micro surfacing
GE-N-TYP-SURF-OFC CONTINUOUS 3 Green 7 0.30 OFC surface course
GE-N-TYP-SURF-PCC CONTINUOUS 3 Green 7 0.3 Portland Concrete Surface
GE-N-TYP-SURF-RHM CONTINUOUS 3 Green 7 0.30 RHM surface course
GE-N-TYP-SURF-ST CONTINUOUS 1 Red 1 0.20 Surface treatment

app5-geotech Page 4 of 5
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
GE-N-TYP-TEXT-GRID CONTINUOUS 6 Magenta 5 0.60 Title grid text
GE-N-TYP-TEXT-TLE CONTINUOUS 7 White 6 0.75 Title block text

app5-geotech Page 5 of 5
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-6

LAYER STANDARDS

For

ONTARIO PROVINCIAL STANDARD DRAWINGS


PROVINCIAL STANDARDS LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC )

The OPS Layer Standards apply a drafting-oriented approach

Discipline (AA): The following abbreviations are used:


OPS - Ontario Provincial Standards

Status (B): The following abbreviations are used:


S - Standard

Feature (CCC-CC): The feature portion of the layer name defines the drafting specific definition of the layer content

The following abbreviations are used:


BORDER - Drawing Frame and Title Block Information
L# - Solid Lines
CL# - Centre Lines
DL# - Dashed Lines
P# - Hatch Pattern
CONS - Construction Line
DIM - Dimension
TEXT - Text

NOTE:
The drawings from the OPS library published prior to the year 2000 must be converted to comply with
IES CAD R2.1 before any further modification (the proper routine is included in the menu).
The conversion process may leave some old layers (from the IES CAD R2) because there is a hatch
incompatibility between AutoCAD R12 and R13.

app6-opsd Page 1 of 3
Pen
Full-Tone Thickness
Layer LineStyle Color# Color (mm) Description
==============
Border Layers
==============
DWGINFO CONTINUOUS 7 White No Plot Drawing Information
BORDER CONTINUOUS 6 Magenta 0.75 Border, Frame, Title Block & Logo
==============
Line Layers
==============
OPS-S-75MM-L CONTINUOUS 6 Magenta 0.75 Entity Line - Broad Line
OPS-S-25MM-CL1 OPS-CL1 2 Yellow 0.25 Centre line 1 - 0.25mm
OPS-S-25MM-CL2 OPS-CL2 22 Red Shade 0.25 Center line 2 - 0.25mm
OPS-S-25MM-CL3 OPS-CL3 92 Green Shade 0.25 User Defined Line - 0.25mm
OPS-S-25MM-CL4 OPS-CL4 132 Cyan Shade 0.25 User Defined Line - 0.25mm
OPS-S-15MM-CL1 OPS-CL1 13 Red Shade 0.15 Centre line 1 - 0.15mm
OPS-S-15MM-CL2 OPS-CL2 13 Red Shade 0.15 Centre line 1 - 0.15mm
OPS-S-15MM-CL3 OPS-CL3 13 Red Shade 0.15 User Defined Line - 0.15mm
OPS-S-15MM-CL4 OPS-CL4 13 Red Shade 0.15 User Defined Line - 0.15mm
OPS-S-25MM-DL1 OPS-DL1 92 Green Shade 0.25 Dashed Line - 0.25mm
OPS-S-25MM-DL2 OPS-DL2 132 Cyan Shade 0.25 Dashed Line - 0.25mm
OPS-S-15MM-DL1 OPS-DL1 13 Red Shade 0.15 Dashed Line - 0.15mm
OPS-S-15MM-DL2 OPS-DL1 13 Red Shade 0.15 Dashed Line - 0.15mm
OPS-S-40MM-DL3 OPS-DL3 63 Light Yellow 0.40 Dashed Line - 0.40mm
OPS-S-40MM-DL4 OPS-DL4 183 Blue shade 0.40 Dashed Line - 0.40mm
OPS-S-25MM-DL5 OPS-DL5 92 Green Shade 0.25 User Defined Line - 0.25mm
OPS-S-25MM-DL6 OPS-DL6 132 Cyan Shade 0.25 User Defined Line - 0.25mm
OPS-S-40MM-DL7 OPS-DL7 63 Light Yellow 0.40 User Defined Line - 0.40mm
OPS-S-40MM-DL8 OPS-DL8 183 Blue shade 0.40 User Defined Line - 0.40mm
OPS-S-50MM-DL9 OPS-DL9 4 Cyan 0.50 User Defined Line - 0.50mm
OPS-S-25MM-L1 CONTINUOUS 22 Red Shade 0.25 Entity Line - 0.25mm
OPS-S-15MM-L1 CONTINUOUS 13 Red Shade 0.15 Entity Line - 0.15mm
OPS-S-25MM-L2 CONTINUOUS 92 Green Shade 0.25 Entity Line - 0.25mm
OPS-S-15MM-L2 CONTINUOUS 13 Red Shade 0.15 Entity Line - 0.15mm
OPS-S-40MM-L1 CONTINUOUS 63 Light Yellow 0.40 Entity Line - 0.40mm
OPS-S-40MM-L2 CONTINUOUS 183 Blue shade 0.40 Entity Line - 0.40mm

app6-opsd Page 2 of 3
Pen
Full-Tone Thickness
Layer LineStyle Color# Color (mm) Description
OPS-S-50MM-L CONTINUOUS 4 Cyan 0.50 Entity Line - 0.50mm
==============
Hatch Layers
==============
OPS-S-25MM-P1 CONTINUOUS 22 Red Shade 0.25 Hatch Pattern - 0.25mm
OPS-S-25MM-P2 CONTINUOUS 92 Green Shade 0.25 Hatch Pattern - 0.25mm
OPS-S-25MM-P3 CONTINUOUS 132 Cyan Shade 0.25 Hatch Pattern - 0.25mm
OPS-S-25MM-P4 CONTINUOUS 2 Yellow 0.25 Hatch Pattern - 0.25mm
OPS-S-15MM-P1 CONTINUOUS 13 Red Shade 0.15 Hatch Pattern - 0.15mm
OPS-S-15MM-P2 CONTINUOUS 13 Red Shade 0.15 Hatch Pattern - 0.15mm
OPS-S-15MM-P3 CONTINUOUS 13 Red Shade 0.15 Hatch Pattern - 0.15mm
OPS-S-15MM-P4 CONTINUOUS 13 Red Shade 0.15 Hatch Pattern - 0.15mm
OPS-S-40MM-P1 CONTINUOUS 63 Light Yellow 0.40 Hatch Pattern - 0.40mm
OPS-S-40MM-P2 CONTINUOUS 183 Blue shade 0.40 Hatch Pattern - 0.40mm
OPS-S-40MM-P3 CONTINUOUS 3 Green 0.40 Hatch Pattern - 0.40mm
OPS-S-50MM-P1 CONTINUOUS 4 Cyan 0.50 Hatch Pattern - 0.50mm
OPS-S-50MM-P2 CONTINUOUS 214 Purple 0.50 Hatch Pattern - 0.50mm
==============
Dimension Layer
==============
OPS-S-DIM CONTINUOUS 132 Cyan Shade 0.25 Dimension Line
OPS-S-DIM15 CONTINUOUS 13 Red Shade 0.15 Dimension Line
==============
Text Layer
==============
OPS-S-TEXT CONTINUOUS 7 White varies Varies size: see Chapter 5.1
==============
Temporary Work Layer
==============
OPS-S-CONS CONTINUOUS 8 Grey No Plot Construction (working) line

app6-opsd Page 3 of 3
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-7

LAYER STANDARDS

For

PLANNING & DESIGN DRAWINGS


PLANNING & DESIGN LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC-D )

Discipline (AA): The following abbreviations are used:


MT - MTO common
PD - Planning & Design

Status (B): The following abbreviations are used:


G - General (non-feature specific)
N - New Construction (Plan)
R - Removals ( Plan)
P - Profile
T - Typical Sections (NOTE - a "drafting-oriented" layering approach
is defined for Typical Sections)

Feature (CCC-CC): The feature portion of the layer name is defined by 2 components.
- the 1st portion indentifies a feature group
- the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:


ALI - Alignments MSC - Miscellaneous
BAR - Barriers PMK - Pavement Markings
BED - Road Bed RDS - Roadways
DRN - Drainage ROW - Right of Way
GND - Ground VEG - Vegetation

Annotation (D): The annotation portion is generally applied at the "feature-group" level.
For example: PD-N-BAR-T

app7-design Page 1 of 8
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
General Layers
==============
BORDER CONTINUOUS 6 Magenta 135 0.75 Frame - Title Block Borders
DWGINFO CONTINUOUS 7 White 9 No Plot Drawing Specific Information
VPORTS CONTINUOUS 4 Cyan 8 No Plot View Port - Paper Space Limits
MT-G-GRID CONTINUOUS 171 Blue 251 0.20 Grid
MT-G-GRID-T TEXT 171 Blue 251 0.20 Grid Text
MT-P-GRID CONTINUOUS 251 Grey 251 0.20 Profile Grid
MT-P-GRID-T TEXT 254 Grey 254 0.25 Profile Grid Text
PD-G-CONS CONTINUOUS 1 Red 251 No Plot Temporary Construction Lines
PD-G-DIM CONTINUOUS 2 Yellow 254 0.25 Dimensions
PD-G-LEGEND CONTINUOUS 50 Yellow 9 0.30 Keyplan - Legend
PD-G-25MM CONTINUOUS 2 Yellow 254 0.25 0.25mm Lines
PD-G-40MM CONTINUOUS 3 Green 253 0.40 0.40mm Lines
PD-G-50MM CONTINUOUS 4 Cyan 8 0.50 0.50mm Lines
PD-G-75MM CONTINUOUS 6 Magenta 135 0.75 0.75mm Lines
PD-G-TEXT TEXT 2 Yellow 254 0.25 General Text
PD-N-LIMIT CONTINUOUS 7 White 9 0.30 Contract - Construction Limits
==============
Alignment Layers
==============
PD-N-ALI-CL CONTINUOUS 20 Red 9 0.30 Centerline Alignment
PD-N-ALI-CL-T TEXT 32 Orange 254 0.25 Centerline Alignment Text
PD-N-ALI-CL-PTS CONTINUOUS 7 White 9 0.30 Centerline Alignment Points
==============
Barrier Layers
==============
PD-N-BAR-FL FENCE 52 Yellow 254 0.25 Fence
PD-N-BAR-GU3 GUIDERAIL 190 Magenta 9 0.30 Guide Rail (3 Cable)
PD-N-BAR-GU6 GUIDERAIL 190 Magenta 9 0.30 Guide Rail (6 Cable)
PD-N-BAR-GUB GUIDERAIL 190 Magenta 9 0.30 Guide Rail (Box Beam)
PD-N-BAR-GUC GUIDERAIL 190 Magenta 9 0.30 Guide Rail (Concrete Barrier)
PD-N-BAR-GUI GUIDERAIL 190 Magenta 9 0.30 Guide Rail (IBC)

app7-design Page 2 of 8
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
PD-N-BAR-GUS GUIDERAIL 190 Magenta 9 0.30 Guide Rail (Steel Beam)
PD-N-BAR-IBM SYMBOL 192 Magenta 254 0.25 Inertial Barrier Modules (IBM)
PD-N-BAR-JB CONTINUOUS 130 Cyan 9 0.30 Jersey Barrier
PD-N-BAR-NB CONTINUOUS 240 Red 9 0.30 Noise Barrier
PD-N-BAR-T TEXT 2 Yellow 254 0.25 Barrier Text
==============
Drainage Layers
==============
PD-N-DRN-BD R-O-W 50 Yellow 9 0.30 Bottom Of Ditch
PD-N-DRN-CB SYMBOL 142 Cyan 254 0.25 Catch Basin
PD-N-DRN-CV CONTINUOUS 140 Cyan 9 0.30 Culvert
PD-N-DRN-DI SYMBOL 142 Cyan 254 0.25 Ditch Inlet
PD-N-DRN-MH SYMBOL 192 Magenta 254 0.25 Manhole
PD-N-DRN-RR CONTINUOUS 142 Cyan 254 0.25 Rip-Rap
PD-N-DRN-SAN R-O-W 130 Cyan 9 0.30 Sanitary Sewer Pipe
PD-N-DRN-SEW SUBGRADE 4 Cyan 8 0.50 Storm Sewer Pipe
PD-N-DRN-SUB SUBGRADE 130 Cyan 9 0.30 Sub Drain
PD-N-DRN-WL CONTINUOUS 162 Blue 254 0.25 Water Level
PD-N-DRN-T TEXT 2 Yellow 254 0.25 Drainage Text
==============
Miscellaneous Layers
==============
PD-N-MSC CONTINUOUS 150 Cyan 9 0.30 Miscellaneous (generic items)
PD-N-MSC-AS CONTINUOUS 92 Green 254 0.25 Asphalt (Miscellaneous Paving)
PD-N-MSC-BN SYMBOL 32 Orange 254 0.25 Bull Nose
PD-N-MSC-CO CONTINUOUS 22 Red 254 0.25 Concrete
PD-N-MSC-COA CONTINUOUS 92 Green 254 0.25 Concrete with Asphalt Surface
PD-N-MSC-EJ CONTINUOUS 192 Magenta 254 0.25 Expansion Joint
PD-N-MSC-GAB CONTINUOUS 130 Cyan 9 0.30 Gabion Baskets
PD-N-MSC-RW CONTINUOUS 22 Red 254 0.25 Retaining Wall
PD-N-MSC-SIGN CONTINUOUS 22 Red 254 0.25 Sign Footing
PD-N-MSC-SWA CONTINUOUS 192 Magenta 254 0.25 Sidewalk (Asphalt)
PD-N-MSC-SWC CONTINUOUS 192 Magenta 254 0.25 Sidewalk (Concrete)
PD-N-MSC-T TEXT 2 Yellow 254 0.25 Miscellaneous Text

app7-design Page 3 of 8
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Pavement Marking Layers
==============
PD-N-PMK CONTINUOUS 50 Yellow 9 0.30 Pavement Markings
PD-N-PMK-GORE CONTINUOUS 40 Orange 9 0.30 Gore Area
PD-N-PMK-PMBW DASHED 7 White 9 0.30 Broken White Line
PD-N-PMK-PMBY DASHED 50 Yellow 9 0.30 Broken Yellow Line
PD-N-PMK-PMSW CONTINUOUS 7 White 9 0.30 Solid White Line
PD-N-PMK-PMSY CONTINUOUS 50 Yellow 9 0.30 Solid Yellow Line
PD-N-PMK-T TEXT 2 Yellow 254 0.25 Pavement Marking Text
==============
Roadway Layers
==============
PD-N-RDS-CGA CONTINUOUS 25 Red 252 0.60 Curb and Gutter (Asphalt)
PD-N-RDS-CGC CONTINUOUS 25 Red 252 0.60 Curb and Gutter (Concrete)
PD-N-RDS-EP CONTINUOUS 50 Yellow 9 0.30 Edge of Pavement
PD-N-RDS-EPS CONTINUOUS 90 Green 9 0.30 Paved Shoulder
PD-N-RDS-ES CONTINUOUS 43 Orange 253 0.40 Granular Shoulder
PD-N-RDS-TC CONTINUOUS 90 Green 9 0.30 Top of Cut
PD-N-RDS-TS SHORTDASH 160 Blue 9 0.30 Toe of Fill Slope
PD-N-RDS-UR GR-ROAD 50 Yellow 9 0.30 Unpaved Road
PD-N-RDS-T TEXT 2 Yellow 254 0.25 Road Text
==============
Property and Right of Way Layers
==============
PD-N-ROW-PLI ROW-PLI 210 Magenta 134 1.00 Limited Interest ( Permanent)
PD-N-ROW-TLI ROW-TLI 40 Orange 134 1.00 Limited Interest (Temporary)
PD-N-ROW-PRI ROW-PRI 20 Red 134 1.00 Property Required (Intermediate)
PD-N-ROW-PRU ROW-PRU 50 Yellow 134 1.00 Property Required (Ultimate)
PD-N-ROW-DEL CONTINUOUS 20 Red 9 0.30 Property Deletion
PD-N-ROW-T TEXT 2 Yellow 254 0.25 Property and ROW Text
==============
Vegetation Layers
==============

app7-design Page 4 of 8
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
PD-N-VEG-SOD CONTINUOUS 82 Green 254 0.25 Sod
PD-N-VEG-WO BUSH 102 Green 254 0.25 Wood Outline
PD-N-VEG-T TEXT 2 Yellow 254 0.25 Vegetation Text
==============
General Profile Layers
==============
PD-P-LIMIT CONTINUOUS 7 White 9 0.30 Contract - Construction Limits
PD-P-LIMIT-T TEXT 192 Magenta 254 0.40 Job Limits Text
==============
Road Bed Profile Layers
==============
PD-P-BED-GRA CONTINUOUS 163 Blue 253 0.40 Top of Granular 'A'
PD-P-BED-GRB CONTINUOUS 3 Green 253 0.40 Top of Granular 'B'
PD-P-BED-SG SUBGRADE 43 Orange 253 0.40 Subgrade
PD-P-BED-TCL CUTLT 33 Red 253 0.40 Top of Cut - Left
PD-P-BED-TCR CUTRT 93 Green 253 0.40 Top of Cut - Right
PD-P-BED-TF CONTINUOUS 143 Cyan 253 0.40 Top of Filter Course
PD-P-BED-TP CONTINUOUS 216 Magenta 135 0.75 Top of Pavement
PD-P-BED-TSL SLOPELT 63 Yellow 253 0.40 Toe of Fill Slope - Left
PD-P-BED-TSR SLOPERT 153 Cyan 253 0.40 Toe of Fill Slope - Right
PD-P-BED-VALBL TEXT 63 Yellow 253 0.40 Vert. Align. Stations - Tables
PD-P-BED-VAPTS CONTINUOUS 54 Yellow 8 0.50 Vert. Align. VPI - Tangents
PD-P-BED-T TEXT 2 Yellow 254 0.25 Profile RoadBed Text

app7-design Page 5 of 8
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Drainage Profile Layers
==============
PD-P-DRN-BDL DITCHLT 143 Cyan 253 0.40 Bottom Of Ditch - Left
PD-P-DRN-BDM DITCHM 193 Magenta 253 0.40 Bottom Of Ditch - Median
PD-P-DRN-BDR DITCHRT 3 Green 253 0.40 Bottom Of Ditch - Right
PD-P-DRN-CB SYMBOL 33 Red 253 0.40 Catch Basin
PD-P-DRN-CV SYMBOL 193 Magenta 253 0.40 Culvert
PD-P-DRN-MH SYMBOL 33 Red 253 0.40 Manhole
PD-P-DRN-SAN CONTINUOUS 3 Green 253 0.40 Sanitary Sewer Pipe
PD-P-DRN-SEW CONTINUOUS 3 Green 253 0.40 Storm Sewer Pipe
PD-P-DRN-SUB CONTINUOUS 143 Cyan 253 0.40 Sub Drain
PD-P-DRN-T TEXT 2 Yellow 254 0.25 Profile Drainage Text
==============
Ground Profile Layers
==============
PD-P-GND-MUB MUSKEG 163 Blue 253 0.40 Bottom Of Muskeg
PD-P-GND-MUT MUSKEG 193 Magenta 253 0.40 Top Of Muskeg
PD-P-GND-OG CONTINUOUS 3 Green 253 0.40 Original Ground
PD-P-GND-RK ROCK 33 Red 253 0.40 Top of Rock
PD-P-GND-T TEXT 2 Yellow 254 0.25 Profile Ground Text
==============
Miscellaneous Profile Layers
==============
PD-P-MSC CONTINUOUS 63 Yellow 253 0.40 Miscellaneous (generic lines)
PD-P-MSC-EF CONTINUOUS 43 Orange 253 0.40 Earth Fill
PD-P-MSC-EX EARTH 43 Orange 253 0.40 Bottom of Earth (or Rock) Excavation
PD-P-MSC-RF CONTINUOUS 33 Red 253 0.40 Rock Fill
PD-P-MSC-SH DASHED 33 Red 253 0.40 Shatter
PD-P-MSC-T TEXT 2 Yellow 254 0.25 Profile Miscellaneous Text

app7-design Page 6 of 8
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Removal Layers
==============
PD-R-BAR-FL FENCE 152 Cyan 254 0.25 Fence
PD-R-BAR-GU GUIDERAIL 150 Cyan 9 0.30 Guide Rail
PD-R-BAR-T TEXT 2 Yellow 254 0.25 Removal Barrier Text
PD-R-DRN-CB SYMBOL 152 Cyan 254 0.25 Catch Basin
PD-R-DRN-CV CONTINUOUS 150 Cyan 9 0.30 Culvert
PD-R-DRN-MH SYMBOL 152 Cyan 254 0.25 Manhole
PD-R-DRN-SAN R-O-W 150 Cyan 8 0.50 Sanitary Sewer Pipe
PD-R-DRN-SEW SUBGRADE 154 Cyan 9 0.30 Storm Sewer Pipe
PD-R-DRN-SUB SUBGRADE 150 Cyan 8 0.50 Sub Drain
PD-R-DRN-T TEXT 2 Yellow 254 0.25 Removal Drainage Text
PD-R-MSC CONTINUOUS 150 Cyan 9 0.30 Miscellaneous (generic items)
PD-R-MSC-AS CONTINUOUS 150 Cyan 9 0.30 Asphalt Pavement
PD-R-MSC-CO CONTINUOUS 150 Cyan 9 0.30 Concrete Pavement
PD-R-MSC-COA CONTINUOUS 150 Cyan 9 0.30 Concrete with Asphalt Surface
PD-R-MSC-SWA CONTINUOUS 152 Cyan 254 0.25 Sidewalk (Asphalt)
PD-R-MSC-SWC CONTINUOUS 152 Cyan 254 0.25 Sidewalk (Concrete)
PD-R-MSC-T TEXT 2 Yellow 254 0.25 Removal Miscellaneous Text
PD-R-RDS-CGA CONTINUOUS 175 Blue 252 0.60 Curb and Gutter (Asphalt)
PD-R-RDS-CGC CONTINUOUS 175 Blue 252 0.60 Curb and Gutter (Concrete)
PD-R-RDS-UR GR-ROAD 150 Cyan 9 0.30 Edge of Unpaved Road
PD-R-RDS-T TEXT 2 Yellow 254 0.25 Removal Road Text
PD-R-VEG-CLR CONTINUOUS 150 Cyan 9 0.30 Cleared
PD-R-VEG-CLRCUT CONTINUOUS 152 Cyan 254 0.25 Close Cut Cleared
PD-R-VEG-CLRGRB CONTINUOUS 150 Cyan 9 0.30 Cleared & Grubbed
PD-R-VEG-GRB CONTINUOUS 152 Cyan 254 0.25 Grubbed
PD-R-VEG-T TEXT 2 Yellow 254 0.25 Removal Vegetation Text

app7-design Page 7 of 8
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Typical Section Layers
==============
PD-T-25MM CONTINUOUS 132 Cyan 254 0.25 0.25mm Line
PD-T-25MM-P CONTINUOUS 132 Cyan 254 0.25 0.25mm Hatch
PD-T-30MM CONTINUOUS 7 White 9 0.30 0.30mm Line
PD-T-30MM-P CONTINUOUS 7 White 9 0.30 0.30mm Hatch
PD-T-40MM CONTINUOUS 33 Red 253 0.40 0.40mm Line
PD-T-40MM-DASH DASHED 33 Red 253 0.40 0.40mm Dashed Line
PD-T-50MM CONTINUOUS 24 Red 8 0.50 0.50mm Line
PD-T-50MM-P CONTINUOUS 24 Red 8 0.50 0.50mm Hatch
PD-T-75MM CONTINUOUS 6 Magenta 135 0.75 0.75mm Line
PD-T-CL CENTER 22 Red 254 0.25 Centerline
PD-T-DIM CONTINUOUS 132 Cyan 254 0.25 Dimensions
PD-T-OG MEDDASH 90 Green 9 0.30 Original Ground
PD-T-NOTE-T TEXT 91 Green 251 0.20 General Notes
PD-T-TEXT TEXT 91 Green 251 0.20 All Text for Typicals

app7-design Page 8 of 8
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-8

LAYER STANDARDS

For

PHOTOGRAMMETRY DRAWINGS
PHOTOGRAMMETRY LAYER DEFINITIONS
- January 2000 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC-D )

Discipline (AA): The following abbreviations are used:


MT - MTO common
PH - Photogrammetry

Status (B): The following abbreviations are used:


G - General (non-feature specific)
E - Existing Plan

Feature (CCC-CC): The feature portion of the layer name is defined by 2 components.
- the 1st portion indentifies a feature group
- the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:


ALI - Alignments MON - Survey Monuments & Control
BAR - Barriers MSC - Miscellaneous
CTR - Contours RDS - Roadways
DRN - Drainage UTL - Utilities
GND - Ground VEG - Vegetation

Annotation (D): The annotation portion is generally applied at the "feature-group" level.
For example: PH-E-BAR-T

Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============

app8-photog Page 1 of 6
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
General Layers
==============
BORDER CONTINUOUS 6 Magenta 135 0.75 Borders
DWGINFO CONTINUOUS 7 White 9 No Plot Drawing Info
VPORTS CONTINUOUS 4 Cyan 8 No Plot View Port
MT-G-GRID CONTINUOUS 171 Blue 251 0.20 Grid
MT-G-GRID-T TEXT20 171 Blue 251 0.20 Grid Text
MT-P-GRID CONTINUOUS 251 Grey 251 0.20 Profile Grid
MT-P-GRID-T TEXT20 252 Grey 254 0.25 Profile Grid Text
PH-G-25MM CONTINUOUS 2 Yellow 254 0.25 0.25mm Line
PH-G-40MM CONTINUOUS 3 Green 253 0.40 0.40mm Line
PH-G-50MM CONTINUOUS 4 Cyan 8 0.50 0.50mm Line
PH-G-75MM CONTINUOUS 6 Magenta 135 0.75 0.75mm Line
PH-G-TEXT TEXT 2 Yellow 254 0.25 General Text
PH-E-SCANNED CONTINUOUS 21 Red 251 0.20 Scanned Image
PH-G-SYMBOLS SYMBOL 2 Yellow 254 0.25 Symbols
PH-E-LABELS TEXT20 1 Red 251 No Plot String Labels
==============
Alignment Layers
==============
PH-E-ALI-E1 CONTINUOUS 20 Red 9 0.30 Entrance Alignment
==============
Barrier Layers
==============
PH-E-BAR-BB CONTINUOUS 200 Magenta 9 0.30 Barrier Concrete (Bottom)
PH-E-BAR-BT CONTINUOUS 200 Magenta 9 0.30 Barrier Concrete (Top)
PH-E-BAR-FL FENCE 90 Green 9 0.30 Fence (Top)
PH-E-BAR-GAT CONTINUOUS 90 Green 9 0.30 Gate
PH-E-BAR-GU GUIDERAIL 140 Cyan 9 0.30 Guide Rail (Plan Only)
PH-E-BAR-NB CONTINUOUS 210 Magenta 9 0.30 Noise Barrier (Top)
PH-E-BAR-T TEXT25 2 Yellow 254 0.25 Barrier Text
==============
Contour Layers
==============

app8-photog Page 2 of 6
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
PH-E-CTR-C1 CONTINUOUS 54 Yellow 8 0.50 Contours (Primary)
PH-E-CTR-C2 CONTINUOUS 20 Red 9 0.30 Contours (Secondary)
PH-E-CTR-T TEXT25 2 Yellow 254 0.25 Contour Text
==============
Drainage Layers
==============
PH-E-DRN-BD R-O-W 150 Cyan 9 0.30 Bottom Of Ditch
PH-E-DRN-CB SYMBOL 170 Blue 9 0.30 Catch Basin
PH-E-DRN-CVP SYMBOL 150 Cyan 9 0.30 Culvert (One End)
PH-E-DRN-CV-P CONTINUOUS 150 Cyan 9 0.30 Culvert Outline
PH-E-DRN-CVT CONTINUOUS 150 Cyan 9 0.30 Culvert Centreline (Top)
PH-E-DRN-DI SYMBOL 170 Blue 9 0.30 Ditch Inlet
PH-E-DRN-EM SHORTDASH 110 Green 9 0.30 Edge of Muskeg
PH-E-DRN-EM-P CONTINUOUS 110 Green 9 0.30 Muskeg Pattern
PH-E-DRN-EW CONTINUOUS 154 Cyan 8 0.50 Edge of Water
PH-E-DRN-MH SYMBOL 170 Blue 9 0.30 Manhole San. or Sewer
PH-E-DRN-RR GR-DRIVE 70 Yellow/Green 9 0.30 Rip-Rap
PH-E-DRN-T TEXT25 2 Yellow 254 0.25 Drainage Text
==============
Ground Feature Layers
==============
PH-E-GND-AO CONTINUOUS 50 Yellow 9 0.30 Asphalt Outline
PH-E-GND-AS CONTINUOUS 40 Orange 9 0.30 Asphalt Shots
PH-E-GND-BA CONTINUOUS 140 Cyan 9 0.30 Bank of River or Stream
PH-E-GND-BC GR-DRIVE 100 Green 9 0.30 Bottom of Rock Cut
PH-E-GND-CO CONTINUOUS 180 Blue 9 0.30 Concrete Outline
PH-E-GND-CS CONTINUOUS 150 Cyan 9 0.30 Concrete Shots
PH-E-GND-EC LONGDASH 20 Red 9 0.30 Entrance Centerline
PH-E-GND-GO GR-DRIVE 40 Orange 9 0.30 Gravel Outline
PH-E-GND-GS CONTINUOUS 40 Orange 9 0.30 Gravel Shots
PH-E-GND-GX CONTINUOUS 40 Orange 9 0.30 Original Ground (Approximate)
PH-E-GND-OG CONTINUOUS 210 Magenta 9 0.30 Original Ground Fault
PH-E-GND-PG SYMBOL 210 Magenta 9 0.30 Original Ground Point
PH-E-GND-RBE SHORTDASH 40 Orange 9 0.30 Railway Ballast Edge

app8-photog Page 3 of 6
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
PH-E-GND-RBT CONTINUOUS 40 Orange 9 0.30 Railway Ballast Top
PH-E-GND-RKO CONTINUOUS 50 Yellow 9 0.30 Rock Outline
PH-E-GND-RKS CONTINUOUS 50 Yellow 9 0.30 Rock Shots
PH-E-GND-SP GR-DRIVE 40 Orange 9 0.30 Stock Piles - Gravel Pits
PH-E-GND-TC CONTINUOUS 100 Green 9 0.30 Top of Rock Cut
PH-E-GND-XX CONTINUOUS 200 Magenta 9 0.30 Original Ground (Estimated)
PH-E-GND-P CONTINUOUS 110 Green 9 0.30 Ground Patterning (ie. Cut - Fill)
PH-E-GND-T TEXT25 2 Yellow 254 0.25 Ground Feature Text
==============
Miscellaneous Layers
==============
PH-E-MSC-AX CONTINUOUS 9 Grey 9 0.30 Excluded Area
PH-E-MSC-AX-P CONTINUOUS 9 Grey 9 0.30 Excluded Area Pattern
PH-E-MSC-BLF SHORTDASH 230 Red 9 0.30 Building Foundations - Ruins
PH-E-MSC-BLR CONTINUOUS 230 Red 9 0.30 Building Roofline Rectangular
PH-E-MSC-BLR CONTINUOUS 230 Red 9 0.30 Building Roofline Circular
PH-E-MSC-BS CONTINUOUS 120 Green 9 0.30 Building Surround
PH-E-MSC-BY CONTINUOUS 7 White 9 0.30 Segment Boundary
PH-E-MSC-CE CONTINUOUS 180 Blue 9 0.30 Cemetery
PH-E-MSC-DK CONTINUOUS 40 Orange 9 0.30 Wooden Decks or Docks
PH-E-MSC-EJ CONTINUOUS 210 Magenta 9 0.30 Expansion Joint
PH-E-MSC-EV-Z SYMBOL 80 Yellow/Green 9 0.30 Miscellaneous Elevation
PH-E-MSC-GAB CONTINUOUS 70 Yellow/Green 9 0.30 Gabion Baskets
PH-E-MSC-GC CONTINUOUS 70 Yellow/Green 9 0.30 Golf Course
PH-E-MSC-HR CONTINUOUS 60 Yellow 9 0.30 Bridge Hand Rails
PH-E-MSC-OR CONTINUOUS 180 Blue 9 0.30 Orchard
PH-E-MSC-OS CONTINUOUS 130 Cyan 9 0.30 Overhead Sign
PH-E-MSC-RLT CONTINUOUS 20 Red 9 0.30 Railway - Top of Rail
PH-E-MSC-RW CONTINUOUS 70 Yellow/Green 9 0.30 Retaining Wall - Top
PH-E-MSC-SW CONTINUOUS 20 Red 9 0.30 Sidewalk
PH-E-MSC-VI CONTINUOUS 180 Blue 9 0.30 Vineyard
PH-E-MSC-WW SHORTDASH 40 Orange 9 0.30 Walkways - Trails - Paths
PH-E-MSC-T TEXT25 2 Yellow 254 0.25 Miscellaneous Text
==============

app8-photog Page 4 of 6
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
Roadway Layers
==============
PH-E-RDS-AE CONTINUOUS 50 Yellow 9 0.30 Asphalt Edges
PH-E-RDS-BRD CONTINUOUS 230 Red 9 0.30 Bridge Deck
PH-E-RDS-CR CONTINUOUS 130 Cyan 9 0.30 Crown of Road
PH-E-RDS-CU CONTINUOUS 70 Yellow/Green 9 0.30 Curbs
PH-E-RDS-DL DASHED 130 Cyan 9 0.30 Driving Lane - Edge
PH-E-RDS-EG CONTINUOUS 240 Red 9 0.30 Edge Of Gutter
PH-E-RDS-EN SHORTDASH 50 Yellow 9 0.30 Entrance - Uncertain Surface
PH-E-RDS-EP CONTINUOUS 63 Yellow 253 0.40 Edge Of Pavement
PH-E-RDS-ER CONTINUOUS 50 Yellow 9 0.30 Edge Of Ramp
PH-E-RDS-ES GR-DRIVE 40 Orange 9 0.30 Edge Of Shoulder
PH-E-RDS-NG GR-DRIVE 40 Orange 9 0.30 Entrance - Gravel
PH-E-RDS-NP CONTINUOUS 50 Yellow 9 0.30 Entrance - Paved
PH-E-RDS-RD CONTINUOUS 210 Magenta 9 0.30 Roads - Uncertain Material
PH-E-RDS-UR GR-ROAD 40 Orange 9 0.30 Gravel Sideroads
PH-E-RDS-T TEXT25 2 Yellow 254 0.25 Roadway Text
==============
Survey Monument Layers
==============
PH-E-MON SYMBOL 20 Red 9 0.30 Horizontal Control
PH-E-MON-BM SYMBOL 20 Red 9 0.30 Vertical Control

app8-photog Page 5 of 6
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Utility Layers
==============
PH-E-UTL-AN SYMBOL 210 Magenta 9 0.30 Anchor for Guy Wire
PH-E-UTL-BH SYMBOL 7 White 9 0.30 Bell - Hydro Pole
PH-E-UTL-BP SYMBOL 7 White 9 0.30 Bell Pole
PH-E-UTL-FH SYMBOL 7 White 9 0.30 Fire Hydrant
PH-E-UTL-HP SYMBOL 7 White 9 0.30 Hydro Pole
PH-E-UTL-HT CONTINUOUS 7 White 9 0.30 Hydro Tower
PH-E-UTL-LS SYMBOL 7 White 9 0.30 Light Standard
PH-E-UTL-PW SYMBOL 50 Yellow 9 0.30 Pole Well
PH-E-UTL-PO SYMBOL 7 White 9 0.30 Pole - other
PH-E-UTL-WE SYMBOL 140 Cyan 9 0.30 Well
PH-E-UTL-T TEXT25 2 Yellow 254 0.25 Utilities Text
==============
Vegetation Layers
==============
PH-E-VEG-HE HEDGE 100 Green 9 0.30 Hedge
PH-E-VEG-TR SYMBOL 90 Green 9 0.30 Trees
PH-E-VEG-WD BUSH 90 Green 9 0.30 Woods Detail
PH-E-VEG-WO CONTINUOUS 90 White 9 0.30 Woods Overhang (Top)
PH-E-VEG-T TEXT25 2 Yellow 254 0.25 Vegetation Text

app8-photog Page 6 of 6
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-9

LAYER STANDARDS

For

SURVEYS & PLANS DRAWINGS


SURVEYS & PLANS LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC-D )

Discipline (AA): The following abbreviations are used:


MT - MTO common
SP - Surveys & Plans

Status (B): The following abbreviations are used:


G - General (non-feature specific)
E - Existing Plan
L - Legal Survey
P - Profile
Q - Quality Assurance

Feature (CCC-CC):The feature portion of the layer name is defined by 2 components.


- the 1st portion indentifies a feature group
- the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:


ALI - Alignments MON - Survey Monuments & Control
BAR - Barriers MSC - Miscellaneous
BDY - Property Boundaries RDS - Roadways
CTR - Contours ROW - Right of Way
DRN - Drainage UTL - Utilities
GND - Ground VEG - Vegetation

Annotation (D): The annotation portion is generally applied at the "feature-group" level.
For example: SP-E-BAR-T

Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description

app9-surveys Page 1 of 9
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
General Layers
==============
BORDER CONTINUOUS 6 Magenta 135 0.75 Borders
DWGINFO CONTINUOUS 7 White 9 No Plot Drawing Info
VPORTS CONTINUOUS 4 Cyan 8 No Plot View Port
MT-G-GRID CONTINUOUS 171 Blue 251 0.20 Grid
MT-G-GRID-T TEXT20 171 Blue 251 0.20 Grid Text
MT-P-GRID CONTINUOUS 251 Grey 251 0.20 Profile Grid
MT-P-GRID-T TEXT20 252 Grey 254 0.25 Profile Grid Text
SP-G-CONS CONTINUOUS 7 White 9 No Plot Construction Lines
SP-G-25MM CONTINUOUS 2 Yellow 254 0.25 0.25mm Line
SP-G-40MM CONTINUOUS 3 Green 253 0.40 0.40mm Line
SP-G-50MM CONTINUOUS 4 Cyan 8 0.50 0.50mm Line
SP-G-75MM CONTINUOUS 6 Magenta 9 0.75 0.75mm Line
SP-G-TEXT TEXT 2 Yellow 254 0.25 General Text
SP-G-SYMBOLS SYMBOL 2 Yellow 254 0.25 Symbols
SP-E-LABELS TEXT20 1 Red 251 No Plot String Labels
SP-E-SCANNED CONTINUOUS 21 Red 251 0.20 Scanned Image
==============
Alignment Layers
==============
SP-E-ALI CONTINUOUS 40 Orange 9 0.30 Misc Alignment
SP-E-ALI-CL CONTINUOUS 20 Red 9 0.30 Centerline Alignment
SP-E-ALI-CL-C TEXT25 92 Green 254 0.25 Centerline Alignment Chainage
SP-E-ALI-CL-PTS SYMBOL 50 Yellow 254 0.30 Centerline Alignment Points
SP-E-ALI-CL-T TEXT25 92 Green 254 0.25 Centreline Alignment Text
SP-E-ALI-D1 CONTINUOUS 150 Cyan 9 0.30 Drainage Alignment
SP-E-ALI-E1 CONTINUOUS 20 Red 9 0.30 Entrance Alignment
SP-E-ALI-R1 CONTINUOUS 20 Red 9 0.30 Align Revision - Ramp
SP-E-ALI-S1 CONTINUOUS 20 Red 9 0.30 Sideroad Alignment

app9-surveys Page 2 of 9
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Barrier Layers
==============
SP-E-BAR-BB CONTINUOUS 200 Magenta 9 0.30 Barrier Concrete (Bottom)
SP-E-BAR-BT CONTINUOUS 200 Magenta 9 0.30 Barrier Concrete (Top)
SP-E-BAR-FB CONTINUOUS 90 Green 9 0.30 Fitch Barrier
SP-E-BAR-FL FENCE 90 Green 9 0.30 Fence Line (Ground)
SP-E-BAR-GAT CONTINUOUS 90 Green 9 0.30 Gate
SP-E-BAR-GP-Z SYMBOL 140 Cyan 9 0.30 Guide Rail (Top of Post)
SP-E-BAR-GU GUIDERAIL 140 Cyan 9 0.30 Guide Rail (Ground)
SP-E-BAR-GW-Z SYMBOL 7 White 9 0.30 Guide Rail (Top of Wire)
SP-E-BAR-NB CONTINUOUS 210 Magenta 9 0.30 Noise Barrier (Ground)
SP-E-BAR-T TEXT25 2 Yellow 254 0.25 Barrier Text
==============
Contour Layers
==============
SP-E-CTR-C1 CONTINUOUS 54 Yellow 8 0.50 Contours (Primary)
SP-E-CTR-C2 CONTINUOUS 20 Red 9 0.30 Contours (Secondary)
SP-E-CTR-T TEXT25 2 Yellow 254 0.25 Contour Text
==============
Drainage Layers
==============
SP-E-DRN-BD R-O-W 150 Cyan 9 0.30 Bottom Of Ditch
SP-E-DRN-CB SYMBOL 170 Blue 9 0.30 Catch Basin
SP-E-DRN-CVP SYMBOL 220 Magenta 9 0.30 Culvert (One End)
SP-E-DRN-CV-P CONTINUOUS 150 Cyan 9 0.30 Culvert Symbology
SP-E-DRN-CVT CONTINUOUS 150 Cyan 9 0.30 Culvert Centreline (Top)
SP-E-DRN-CV-Z SYMBOL 150 Cyan 9 0.30 Culvert Elevation
SP-E-DRN-DB-Z SYMBOL 50 Yellow 9 0.30 Ditch Inlet (Bottom Elevation)
SP-E-DRN-DC CONTINUOUS 170 Blue 9 0.30 Ditch Centerline
SP-E-DRN-DI SYMBOL 170 Blue 9 0.30 Ditch Inlet
SP-E-DRN-DT-Z SYMBOL 7 White 9 0.30 Ditch Inlet (Top Elevation)
SP-E-DRN-EM SHORTDASH 110 Green 9 0.30 Edge of Muskeg
SP-E-DRN-EM-P CONTINUOUS 110 Green 9 0.30 Muskeg Pattern

app9-surveys Page 3 of 9
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
SP-E-DRN-EW CONTINUOUS 154 Cyan 8 0.50 Edge of Water
SP-E-DRN-FR-Z SYMBOL 140 Cyan 9 0.30 Frustrum Elevation
SP-E-DRN-MH SYMBOL 170 Blue 9 0.30 Manhole San. or Sewer
SP-E-DRN-RR GR-DRIVE 70 Yellow/Green 9 0.30 Rip-Rap
SP-E-DRN-SAN CONTINUOUS 130 Cyan 9 0.30 Sanitary Sewer Pipes
SP-E-DRN-SEW CONTINUOUS 130 Cyan 9 0.30 Storm Sewer Pipes
SP-E-DRN-SU-Z SYMBOL 150 Cyan 9 0.30 Sump Elevation
SP-E-DRN-WM CONTINUOUS 160 Blue 9 0.30 Water Mark
SP-E-DRN-T TEXT25 2 Yellow 254 0.25 Drainage Text
==============
Ground Feature Layers
==============
SP-E-GND-AO CONTINUOUS 50 Yellow 9 0.30 Asphalt Outline
SP-E-GND-AS CONTINUOUS 40 Orange 9 0.30 Asphalt Shots
SP-E-GND-BA CONTINUOUS 140 Cyan 9 0.30 Bank of River or Stream
SP-E-GND-BC GR-DRIVE 100 Green 9 0.30 Bottom of Rock Cut
SP-E-GND-CO CONTINUOUS 180 Blue 9 0.30 Concrete Outline
SP-E-GND-CS CONTINUOUS 150 Cyan 9 0.30 Concrete Shots
SP-E-GND-DS CONTINUOUS 120 Green 9 0.30 Door Sill
SP-E-GND-EC LONGDASH 20 Red 9 0.30 Entrance Centerline
SP-E-GND-GO GR-DRIVE 40 Orange 9 0.30 Gravel Outline
SP-E-GND-GS CONTINUOUS 40 Orange 9 0.30 Gravel Shots
SP-E-GND-OG CONTINUOUS 210 Magenta 9 0.30 Original Ground Fault
SP-E-GND-PG SYMBOL 210 Magenta 9 0.30 Original Ground Point
SP-E-GND-RBE SHORTDASH 40 Orange 9 0.30 Railway Ballast Edge
SP-E-GND-RBT CONTINUOUS 40 Orange 9 0.30 Railway Ballast Top
SP-E-GND-RKO CONTINUOUS 50 Yellow 9 0.30 Rock Outline
SP-E-GND-RKS CONTINUOUS 50 Yellow 9 0.30 Rock Shots
SP-E-GND-SB CONTINUOUS 190 Magenta 9 0.30 River or Stream Bed
SP-E-GND-SP GR-DRIVE 40 Orange 9 0.30 Stock Piles - Gravel Pits
SP-E-GND-TC CONTINUOUS 100 Green 9 0.30 Top of Rock Cut
SP-E-GND-TS GR-DRIVE 120 Green 9 0.30 Toe of Slope
SP-E-GND-P CONTINUOUS 110 Green 9 0.30 Ground Patterning (ie. Cut - Fill)
SP-E-GND-T TEXT25 2 Yellow 254 0.25 Ground Feature Text

app9-surveys Page 4 of 9
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Miscellaneous Layers
==============
SP-Q-MSC-AU CONTINUOUS 7 White 9 0.30 Audit Line
SP-E-MSC-BLO CONTINUOUS 230 Red 9 0.30 Building Outline (Bottom)
SP-E-MSC-BN SYMBOL 20 Red 9 0.30 Centre of Bull Nose
SP-E-MSC-BRP SYMBOL 180 Blue 9 0.30 Bridge Pillar
SP-E-MSC-BY CONTINUOUS 7 White 9 0.30 Segment Boundary
SP-E-MSC-CE CONTINUOUS 180 Blue 9 0.30 Cemetery
SP-E-MSC-DD SYMBOL 230 Red 9 0.30 Deck Drain
SP-E-MSC-DK CONTINUOUS 40 Orange 9 0.30 Wooden Decks or Docks
SP-E-MSC-EJ CONTINUOUS 210 Magenta 9 0.30 Expansion Joint
SP-E-MSC-EV-Z SYMBOL 80 Yellow/Green 9 0.30 Miscellaneous Elevation
SP-E-MSC-GAB CONTINUOUS 70 Yellow/Green 9 0.30 Gabion Baskets
SP-E-MSC-GFL SYMBOL 20 Red 9 0.30 Gate with Flashing Light
SP-E-MSC-HR CONTINUOUS 60 Yellow 9 0.30 Bridge Hand Rails
SP-E-MSC-OS CONTINUOUS 130 Cyan 9 0.30 Overhead Sign
SP-E-MSC-RCS SYMBOL 20 Red 9 0.30 Railway Crossing Sign
SP-E-MSC-RLS SYMBOL 20 Red 9 0.30 Railway Sign
SP-E-MSC-RLT CONTINUOUS 20 Red 9 0.30 Railway - Top of Rail
SP-E-MSC-RW CONTINUOUS 70 Yellow/Green 9 0.30 Retaining Wall - Bottom
SP-E-MSC-SW CONTINUOUS 20 Red 9 0.30 Sidewalk
SP-E-MSC-WW SHORTDASH 40 Orange 9 0.30 Walkways - Trails - Paths
SP-E-MSC-T TEXT25 2 Yellow 254 0.25 Miscellaneous Text
==============
Property Boundary Layers
==============
SP-E-BDY-CITY SUBGRADE 245 Red 252 0.60 City Boundary
SP-E-BDY-LIN LONGDASH 24 Red 8 0.50 General Property Boundary Line
SP-E-BDY-LLS LONGDASH 24 Red 8 0.50 Lot Line - Subdivision Boundary
SP-E-BDY-LLC SYMBOL 20 Red 9 0.30 Lot Line - Concession Boundary
SP-E-BDY-T TEXT25 2 Yellow 254 0.25 Property Boundary Text

app9-surveys Page 5 of 9
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Right of Way Layers
==============
SP-E-ROW-MTO ROW 70 Yellow 9 1.00 Existing MTO Property
SP-E-ROW-T TEXT25 2 Yellow 254 0.25 Right of Way Text
==============
Roadway Layers
==============
SP-E-RDS-AE CONTINUOUS 50 Yellow 9 0.30 Asphalt Edges
SP-E-RDS-BRD CONTINUOUS 230 Red 9 0.30 Bridge Deck
SP-E-RDS-CR CONTINUOUS 130 Cyan 9 0.30 Crown of Road
SP-E-RDS-CU CONTINUOUS 70 Yellow/Green 9 0.30 Curbs
SP-E-RDS-DL DASHED 130 Cyan 9 0.30 Driving Lane - Edge
SP-E-RDS-EG CONTINUOUS 240 Red 9 0.30 Edge Of Gutter
SP-E-RDS-EP CONTINUOUS 63 Yellow 253 0.40 Edge Of Pavement
SP-E-RDS-ER CONTINUOUS 50 Yellow 9 0.30 Edge Of Ramp
SP-E-RDS-ES GR-DRIVE 40 Orange 9 0.30 Edge Of Shoulder
SP-E-RDS-NG GR-DRIVE 40 Orange 9 0.30 Entrance - Gravel
SP-E-RDS-NP CONTINUOUS 50 Yellow 9 0.30 Entrance - Paved
SP-E-RDS-RS CONTINUOUS 210 Magenta 9 0.30 Ripple Strip
SP-E-RDS-SR CONTINUOUS 50 Yellow 9 0.30 Sideroads Paved
SP-E-RDS-UR GR-ROAD 40 Orange 9 0.30 Gravel Sideroads
SP-E-RDS-T TEXT25 2 Yellow 254 0.25 Roadway Text

app9-surveys Page 6 of 9
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
Survey Monument Layers
==============
SP-E-MON SYMBOL 20 Red 9 0.30 Cut Cross
Concrete Monument
Concrete Pin
Primary Horizontal Control Point
Horizontal Project Control Point
Iron Bar
Nail, Spike, Rock Rivet, etc
Rock Bar
Round Iron Bar
Rock Plug
Rock Post
Standard Iron Bar
Short Standard Iron Bar
Primary Vertical Control Point
Vertical Project Control Point
SP-G-MON-T TEXT25 2 Yellow 254 0.25 Monument Text
==============
Utility Layers
==============
SP-E-UTL-AN SYMBOL 210 Magenta 9 0.30 Anchor
SP-E-UTL-BH SYMBOL 7 White 9 0.30 Bell - Hydro Pole
SP-E-UTL-BP SYMBOL 7 White 9 0.30 Bell Pole
SP-E-UTL-FH SYMBOL 7 White 9 0.30 Fire Hydrant
SP-E-UTL-GV SYMBOL 7 White 9 0.30 Gas Valve
SP-E-UTL-HCG-Z CONTINUOUS 140 Cyan 9 0.30 Hydro Crossing Ground Elev
SP-E-UTL-HCW-Z CONTINUOUS 7 White 9 0.30 Hydro Crossing Wire Elev
SP-E-UTL-HP SYMBOL 7 White 9 0.30 Hydro Pole
SP-E-UTL-HT CONTINUOUS 7 White 9 0.30 Hydro Tower
SP-E-UTL-LS SYMBOL 7 White 9 0.30 Light Standard
SP-E-UTL-PL CONTINUOUS 50 Yellow 9 0.30 Pipeline
SP-E-UTL-PO SYMBOL 7 White 9 0.30 Pole - other

app9-surveys Page 7 of 9
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
SP-E-UTL-PW SYMBOL 50 Yellow 9 0.30 Pole Well
SP-E-UTL-TB SYMBOL 50 Yellow 9 0.30 Utility Terminal Box
SP-E-UTL-UB CABLE 40 Orange 9 0.30 Underground Bell
SP-E-UTL-UG CABLE 40 Orange 9 0.30 Underground Gas
SP-E-UTL-UH CABLE 40 Orange 9 0.30 Underground Hydro
SP-E-UTL-UM SYMBOL 50 Yellow 9 0.30 Underground Utility Marker
SP-E-UTL-UT CABLE 40 Orange 9 0.30 Underground Utility - other
SP-E-UTL-VE SYMBOL 50 Yellow 9 0.30 Vent
SP-E-UTL-WE SYMBOL 140 Cyan 9 0.30 Well
SP-E-UTL-WV SYMBOL 140 Cyan 9 0.30 Water Valve
SP-E-UTL-T TEXT25 2 Yellow 254 0.25 Utilities Text
==============
Vegetation Layers
==============
SP-E-VEG-HE HEDGE 100 Green 9 0.30 Hedge
SP-E-VEG-P CONTINUOUS 90 Green 9 0.30 Bush Symbology
SP-E-VEG-TR SYMBOL 90 Green 9 0.30 Trees
SP-E-VEG-WD BUSH 90 Green 9 0.30 Woods Detail
SP-E-VEG-WO BUSH 90 White 9 0.30 Woods Overhang (Ground)
SP-E-VEG-WT CONTINUOUS 50 Yellow 9 0.30 Woods Trunkline
SP-E-VEG-T TEXT25 2 Yellow 254 0.25 Vegetation Text
==============
Profile Layers
==============
SP-P-ALI-CL CONTINUOUS 3 Green 253 0.40 Profile Information
SP-P-ALI-DRN CONTINUOUS 63 Yellow 253 0.40 Drainage Information
SP-P-ALI-DRN-T TEXT25 2 Yellow 254 0.25 Profile Text
SP-P-ALI-GRID CONTINUOUS 1 Red 251 0.20 Profile Grid
SP-P-ALI-GRID-T TEXT25 2 Yellow 254 0.25 Profile Chainage

app9-surveys Page 8 of 9
Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
====================
LEGAL SURVEYS Layers
====================
SP-L-MON SYMBOL 20 Red 9 0.30 Horizontal Control Points
SP-L-MON-BM SYMBOL 20 Red 9 0.30 Bench Marks
SP-G-MON-T TEXT25 2 Yellow 254 0.25 Monument Text
SP-L-25MM CONTINUOUS 2 Yellow 254 0.25 0.25mm Line
SP-L-25MM-SDASH SHORTDASH 2 Yellow 254 0.25 0.25mm Line
SP-L-25MM-LDASH LONGDASH 2 Yellow 254 0.25 0.25mm Line
SP-L-40MM CONTINUOUS 3 Green 253 0.40 0.40mm Line
SP-L-40MM-LDASH LONGDASH 3 Green 253 0.40 0.40mm Line
SP-L-50MM CONTINUOUS 4 Cyan 8 0.50 0.50mm Line
SP-L-PART CONTINUOUS 6 Magenta 135 0.75 0.75mm Line
SP-L-TEXT TEXT 2 Yellow 254 0.25 Legal Text
SP-L-SYMBOLS SYMBOL 2 Yellow 254 0.25 Legal Symbols

app9-surveys Page 9 of 9
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-10

LAYER STANDARDS

For

STRUCTURAL DRAWINGS
STRUCTURAL DESIGN LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC )

Discipline (AA): The following abbreviations are used:


ST - Structural Design

Status (B): The following abbreviations are used:


N - New Construction G - General E - Existing F - Future R - Removal

Feature (CCC): The feature portion of the layer name is generally defined by a single component.

Associated Layer (CC): The following abbreviations are used:


(This layer is optional) T - Text D - Dimension P - Pattern RB - Rebar

NOTE: These layers are generated only when a user decides to select the "By Pick" option when inserting dimensions, text,
pattern (hatching) or rebar for a feature. The proprieties of these layers are similar to the general layers for dimension
(ST-G-DIM), text (ST-G-TEXT), pattern (hatch) (ST-G-HATCH) and the reinforcing steel (ST-E-REBAR and ST-N-REBAR).
See the On-line help for the Structural customisation for more details.

For example, if a user has 2 features on a drawing for a new bridge say abutment and pier. The two features will be on the
ST-N-ABUT and ST-N-PIER layers. The customisation has two options for selecting layers for the dimensions for these
features. In option 1, the dimensions for the abutment and pier can be placed in the general layer ST-G-DIM. In option 2,
the user selects dimension by pick and the customisation will generate a ST-N-ABUT-D layer for the abutment dimensions
and a ST-N-PIER-D layer for the dimensions for the pier. The proprieties of the ST-N-ABUT-D and ST-N-PIER-D layers
are the same as the proprieties for the ST-G-DIM layer.

app10-structural Page 1 of 5
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
===============
Common Layers
===============
BORDER CONTINUOUS 6 Magenta 135 0.75 Borders
DWGINFO CONTINUOUS 7 White 9 0.30 Drawing Info
VPORTS CONTINUOUS 4 Cyan 8 0.50 View Port
===============
General Layers
===============
ST-G-SYMBOLS CONTINUOUS 40 Orange 9 0.30 Structural symbols
ST-G-CENTLN CENTER2 1 Red 251 0.20 Center Line
ST-G-CONS CONTINUOUS 53 254 0.25 Construction lines 0.25mm
ST-G-60MM CONTINUOUS 5 Blue 135 0.60 Detail Linework 0.60mm
ST-G-50MM CONTINUOUS 4 Cyan 8 0.50 Detail Linework 0.50mm
ST-G-40MM CONTINUOUS 3 Green 253 0.40 Detail Linework 0.40mm
ST-G-30MM CONTINUOUS 7 White 9 0.30 Detail Linework 0.30mm
ST-G-25MM CONTINUOUS 2 Yellow 254 0.25 Detail linework 0.25mm
ST-G-DIM CONTINUOUS 1 Red 251 0.20 All dimensions
ST-G-TEXT CONTINUOUS 7 White 9 0.30 All General Text Annotation
ST-G-HATCH CONTINUOUS 1 Red 251 0.20 All hatching
ST-G-MARKUP CONTINUOUS 7 White 9 0.30 Markup
ST-G-MISC CONTINUOUS 7 White 9 0.30 entities not covered by Standard
ST-G-SCANNED CONTINUOUS 7 White 9 0.30 Scanned
===============
Reinforcing Steel
===============
ST-E-REBAR CONTINUOUS 5 252 0.60 Reinforcing Steel
ST-N-REBAR CONTINUOUS 5 Blue 252 0.60 Reinforcing Steel
===============
Substructures
===============
ST-E-ABUT CONTINUOUS 40 Grey 9 0.30 Abutment and Wingwall
ST-E-BRG CONTINUOUS 50 Grey 9 0.30 Bearing
ST-E-CONTOUR HIDDEN 113 Grey 253 0.40 Contours

app10-structural Page 2 of 5
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
ST-E-EARTHEXT CONTINUOUS 40 Grey 9 0.30 Existing earth
ST-E-EARTHMOD CONTINUOUS 40 Grey 9 0.30 Modified earth
ST-E-FOOT CONTINUOUS 50 Grey 9 0.30 Footing
ST-E-PIER CONTINUOUS 40 Grey 9 0.30 Pier
ST-E-PILE CONTINUOUS 104 Grey 8 0.50 Pile
ST-E-RSOIL CONTINUOUS 40 Grey 9 0.30 Retained Soil System
ST-E-RWALL CONTINUOUS 210 Grey 9 0.30 Retaining Wall
ST-E-TEMP CONTINUOUS 40 Grey 9 0.30 Temporary Work
ST-N-ABUT CONTINUOUS 40 Orange 9 0.30 Abutment and Wingwall
ST-N-BRG CONTINUOUS 50 Yellow 9 0.30 Bearing
ST-N-CONTOUR HIDDEN 113 Green 253 0.40 Contours
ST-N-EARTHEXT CONTINUOUS 40 Orange 9 0.30 Existing earth
ST-N-EARTHMOD CONTINUOUS 40 Orange 9 0.30 Modified earth
ST-N-FOOT CONTINUOUS 50 Yellow 9 0.30 Footing
ST-N-PIER CONTINUOUS 40 Orange 9 0.30 Pier
ST-N-PILE CONTINUOUS 104 Green 8 0.50 Pile
ST-N-RSOIL CONTINUOUS 40 Orange 9 0.30 Retained Soil System
ST-N-RWALL CONTINUOUS 210 Magenta 9 0.30 Retaining Wall
ST-N-TEMP CONTINUOUS 40 Orange 9 0.30 Temporary Work
===============
Super Structures
===============
ST-E-APPR CONTINUOUS 80 Grey 9 0.30 Approach Slab
ST-E-ASPH CONTINUOUS 160 Grey 9 0.30 Asphalt and waterproofing
ST-E-BWAL CONTINUOUS 140 Grey 9 0.30 Barrier and Parapet wall 0.30mm
ST-E-CABL CONTINUOUS 160 Grey 9 0.30 Cable and Tendon
ST-E-DECK CONTINUOUS 20 Grey 9 0.30 Deck
ST-E-EXJT CONTINUOUS 230 Grey 9 0.30 Expansion Joint 0.30mm
ST-E-GIRD CONTINUOUS 40 Grey 9 0.30 Girder - X-Frame - P. T. Deck 0.30mm
ST-E-TRUSS CONTINUOUS 50 Grey 9 0.30 Truss 0.30mm
ST-N-APPR CONTINUOUS 80 Green 9 0.30 Approach Slab
ST-N-ASPH CONTINUOUS 160 Blue 9 0.30 Asphalt and waterproofing
ST-N-BWAL CONTINUOUS 140 Cyan 9 0.30 Barrier and Parapet wall 0.30mm
ST-N-CABL CONTINUOUS 160 Blue 9 0.30 Cable and Tendon

app10-structural Page 3 of 5
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
ST-N-DECK CONTINUOUS 20 Red 9 0.30 Deck
ST-N-EXJT CONTINUOUS 230 Red 9 0.30 Expansion Joint 0.30mm
ST-N-GIRD CONTINUOUS 40 Orange 9 0.30 Girder - X-Frame - P. T. Deck 0.30mm
ST-N-TRUSS CONTINUOUS 50 Yellow 9 0.30 Truss 0.30mm
===============
Roadway
===============
ST-E-ALIG CONTINUOUS 70 Grey 9 0.30 Control Alignment
ST-E-PAVT CONTINUOUS 160 Grey 9 0.30 Pavement and Traffic Lanes
ST-E-PROF CONTINUOUS 20 Grey 9 0.30 Road Profile
ST-E-CURB CONTINUOUS 70 Grey 9 0.30 Curb
ST-N-ALIG CONTINUOUS 70 Green 9 0.30 Control Alignment
ST-N-PAVT CONTINUOUS 160 Blue 9 0.30 Pavement and Traffic Lanes
ST-N-PROF CONTINUOUS 20 Red 9 0.30 Road Profile
ST-N-CURB CONTINUOUS 70 Green 9 0.30 Curb
===============
Other Structures
===============
ST-E-CULV CONTINUOUS 160 Grey 9 0.30 Culvert
ST-E-HMPOLE CONTINUOUS 130 Grey 9 0.30 High Mast Lighting Pole and Base 0.30mm
ST-E-SIGN CONTINUOUS 210 Grey 9 0.30 Sign and Sign Support 0.30mm
ST-E-SOILPRT CONTINUOUS 210 Grey 9 0.30 Soil Protection - Concrete Slope Paving
ST-N-CULV CONTINUOUS 160 Blue 9 0.30 Culvert
ST-N-HMPOLE CONTINUOUS 130 Cyan 9 0.30 High Mast Lighting Pole and Base 0.30mm
ST-N-SIGN CONTINUOUS 210 Magenta 9 0.30 Sign and Sign Support 0.30mm
ST-N-SOILPRT CONTINUOUS 210 Magenta 9 0.30 Soil Protection - Concrete Slope Paving
===============
Miscellaneous Features
===============
ST-E-CAMB CONTINUOUS 150 Grey 9 0.30 Camber Diagram
ST-E-ELEC CONTINUOUS 50 Grey 9 0.30 Electrical Embedded Work
ST-E-RAILING CONTINUOUS 160 Grey 9 0.30 Railing
ST-E-RAILWAY CONTINUOUS 20 Grey 9 0.30 Railway
ST-E-UTIL CONTINUOUS 210 Grey 9 0.30 Utility (Bell-Hydro etc.)

app10-structural Page 4 of 5
Pen
Full-Tone Plot Thickness
Layer LineStyle Color# Color Color# (mm) Description
ST-E-WALK CONTINUOUS 160 Grey 9 0.30 Sidewalk
ST-N-CAMB CONTINUOUS 150 Blue 9 0.30 Camber Diagram
ST-N-ELEC CONTINUOUS 50 Yellow 9 0.30 Electrical Embedded Work
ST-N-RAILING CONTINUOUS 160 Blue 9 0.30 Railing
ST-N-RAILWAY CONTINUOUS 20 Red 9 0.30 Railway
ST-N-UTIL CONTINUOUS 210 Magenta 9 0.30 Utility (Bell-Hydro etc.)
ST-N-WALK CONTINUOUS 160 Blue 9 0.30 Sidewalk

app10-structural Page 5 of 5
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-11

LAYER STANDARDS

For

TRAFFIC DRAWINGS
TRAFFIC LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC-D )

Discipline (AA): The following abbreviations are used:


TR - Traffic

Status (B): The following abbreviations are used:


E - Existing Conditions
N - New Construction Conditions
T - Temporary (Schematic)

Feature (CCC-CC): The feature portion of the layer name is generally defined by 2 components.
- the 1st portion indentifies a feature group
- the 2nd portion identifies the feature

The following "feature-group" abbreviations are used:


PMK - Pavement Markings
SIGN - Sign

app11-traffic Page 1 of 4 26/07/2005


Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
General Layers
==============
BORDER CONTINUOUS 6 Magenta 135 0.75 Frame - Title Block Borders
DWGINFO CONTINUOUS 7 White 9 No Plot Drawing Specific Information
VPORTS CONTINUOUS 4 Cyan 8 No Plot View Port - Paper Space Limits
TR-G-CONS CONTINUOUS 8 8 No Plot Construction (working) line
TR-G-DIM CONTINUOUS 132 254 General dimensions
TR-G-HATCH CONTINUOUS 1 251 General hatch pattern
TR-G-TEXT TEXT 3 9 General text
==============
Existing Pavement Markings
==============
TR-E-PMK-ARROWS CONTINUOUS 22 Red 254 0.25 Turning Arrows
TR-E-PMK-BW1 PMK1 3 Green 253 0.40 Broken line for left and right turn lane (3,-3,10)
TR-E-PMK-BW2 PMK1 43 Brown 253 0.40 Continuity line in channelizations (3,-3,20)
TR-E-PMK-BW3 PMK2 43 Brown 253 0.40 Lane dividing line (3,-6,10)
TR-E-PMK-BW4 PMK3 3 Green 253 0.40 Lane dividing line (3,-9,10)
TR-E-PMK-BY1 PMK1 3 Green 253 0.40 Broken yellow for two way left turn lane (3,-3,10)
TR-E-PMK-BY2 PMK2 3 Green 253 0.40 Directional dividing lines (center line) ( 3,-6,10)
TR-E-PMK-CROSSWALK CONTINUOUS 43 Brown 253 0.40 Crosswalk lines
TR-E-PMK-GORE CONTINUOUS 3 Green 253 0.40 Gore area
TR-E-PMK-STOPBAR CONTINUOUS 91 Green 251 0.20 Intersection stop bar
TR-E-PMK-SW1 CONTINUOUS 43 Brown 253 0.40 Edge lines, Lane lines (10cm width)
TR-E-PMK-SW2 CONTINUOUS 3 Brown 253 0.40 Edge line (20cm width)
TR-E-PMK-SY CONTINUOUS 43 Brown 253 0.40 Center line
==============
New Construction Pavement Markings
==============
TR-N-PMK-ARROWS CONTINUOUS 22 254 Turning Arrows
TR-N-PMK-BW1 PMK1 3 Green 253 0.40 Broken line for left and right turn lane (3,-3,10)
TR-N-PMK-BW2 PMK1 43 Brown 253 0.40 Continuity line in channelizations (3,-3,20)
TR-N-PMK-BW3 PMK2 43 Brown 253 0.40 Lane dividing line (3,-6,10)
TR-N-PMK-BW4 PMK3 3 Green 253 0.40 Lane dividing line (3,-9,10)

app11-traffic Page 2 of 4 26/07/2005


Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
TR-N-PMK-BY1 PMK1 3 Green 253 0.40 Broken yellow for two ways left turn lane (3,-3,10)
TR-N-PMK-BY2 PMK2 3 Green 253 0.40 Directional dividing lines (center line) ( 3,-6,10)
TR-N-PMK-CROSSWALK CONTINUOUS 43 Brown 253 0.40 Crosswalk lines
TR-N-PMK-GORE CONTINUOUS 3 Green 253 0.40 Gore area
TR-N-PMK-STOPBAR CONTINUOUS 91 Green 251 0.20 Intersection stop bar
TR-N-PMK-SW1 CONTINUOUS 43 Brown 253 0.40 Edge line, lane line (10cm width)
TR-N-PMK-SW2 CONTINUOUS 3 Green 253 0.40 Edge line (20cm width)
TR-N-PMK-SY CONTINUOUS 43 Brown 253 0.40 Center line
==============
Typical Drawing Pavement Markings
==============
TR-T-PMK-ARROWS CONTINUOUS 22 254 Turning Arrows
TR-T-PMK-BW1 PMK1 3 Green 253 0.40 Broken line for left and right turn lane(3,-3,10)
TR-T-PMK-BW2 PMK1 43 Brown 253 0.40 Continuity line in channelizations (3,-3,20)
TR-T-PMK-BW3 PMK2 43 Brown 253 0.40 Lane dividing line (3,-6,10)
TR-T-PMK-BW4 PMK3 3 Green 253 0.40 Lane dividing line (3,-9,10)
TR-T-PMK-BY1 PMK1 3 Green 253 0.40 Broken yellow for two ways left turn lane (3,-3,10)
TR-T-PMK-BY2 PMK2 3 Green 253 0.40 Directional dividing lines (center line) ( 3,-6,10)
TR-T-PMK-CROSSWALK CONTINUOUS 43 Brown 253 0.40 Crosswalk lines
TR-T-PMK-GORE CONTINUOUS 3 Green 253 0.40 Gore area
TR-T-PMK-STOPBAR CONTINUOUS 91 Green 251 0.20 Intersection stop bar
TR-T-PMK-SW1 CONTINUOUS 3 Green 253 0.40 Edge line, lane line (10cm width)
TR-T-PMK-SW2 CONTINUOUS 3 Green 253 0.40 Edge line (20cm width)
TR-T-PMK-SY CONTINUOUS 43 Brown 253 0.40 Center line
==============
Existing Signs
==============
TR-E-SIGN-REG SYMBOL 3 Green 253 0.40 Regulatory Signs
TR-E-SIGN-WARN SYMBOL 3 Green 253 0.40 Warning Signs
TR-E-SIGN-GUID CONTINUOUS 3 Green 253 0.40 Guide Signs
TR-E-SIGN-MUN CONTINUOUS 3 Green 253 0.40 Municipal boundry and population signs
TR-E-SIGN-TEMP CONTINUOUS 3 Green 253 0.40 Temporary conditions and construction signs
TR-E-SIGN-TOUR CONTINUOUS 3 Green 253 0.40 Tourism and tourist route signs
TR-E-SIGN-SPEC CONTINUOUS 3 Green 253 0.40 Special signs (eg. border crossing/temp.signs)

app11-traffic Page 3 of 4 26/07/2005


Pen
Full-Tone Half-Tone Thickness
Layer LineStyle Color# Color Color# (mm) Description
==============
New Construction Traffic Signs
==============
TR-N-SIGN-REG SYMBOL 3 Green 253 0.40 Regulatory Signs
TR-N-SIGN-WARN SYMBOL 3 Green 253 0.40 Warning Signs
TR-N-SIGN-GUID CONTINUOUS 3 Green 253 0.40 Guide Signs
TR-N-SIGN-MUN CONTINUOUS 3 Green 253 0.40 Municipal boundry and population signs
TR-N-SIGN-TEMP CONTINUOUS 3 Green 253 0.40 Temporary conditions and construction signs
TR-N-SIGN-TOUR CONTINUOUS 3 Green 253 0.40 Tourism and tourist route signs
TR-N-SIGN-SPEC CONTINUOUS 3 Green 253 0.40 Special signs (eg. border crossing/temp.signs)
==============
Typical Drawing Traffic Signs
==============
TR-T-SIGN-REG SYMBOL 3 Green 253 0.40 Regulatory Signs
TR-T-SIGN-WARN SYMBOL 3 Green 253 0.40 Warning Signs
TR-T-SIGN-GUID CONTINUOUS 3 Green 253 0.40 Guide Signs
TR-T-SIGN-MUN CONTINUOUS 3 Green 253 0.40 Municipal boundry and population signs
TR-T-SIGN-TEMP CONTINUOUS 3 Green 253 0.40 Temporary conditions and construction signs
TR-T-SIGN-TOUR CONTINUOUS 3 Green 253 0.40 turism and tourist route signs
TR-T-SIGN-SPEC CONTINUOUS 3 Green 253 0.40 Special signs ( e.g. border crossing/temp.signs

app11-traffic Page 4 of 4 26/07/2005


MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-12

LAYER STANDARDS

For

GEOTECHNICAL DRAWINGS
GEOTECHNICAL DESIGN LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC )

Discipline (AA): The following abbreviations are used:


GE - Geotechnical Design

Status (B): The following abbreviations are used:


N - New Construction G - General E - Existing F - Future R - Removal

Feature (CCC): The feature portion of the layer name is generally defined by a single component.

Associated Layer (CC): The following abbreviations are used:


(This layer is optional) T - Text D - Dimension P - Pattern RB - Rebar

app12-geotech Page 1 of 5
Pen
Full-Tone Plot
Layer LineStyle Weight Description
Color# Color#
(mm)
===============
Common Layers
===============
BORDER CONTINUOUS 6 135 0.70 Border - Frame - Title Block
DWGINFO CONTINUOUS 7 9 0.00 Drawing Info
VPORTS CONTINUOUS 4 8 0.00 View Ports
GE-N-MAP-SYM-CONT SYMBOL 6 135 0.70 Contract number
GE-N-MAP-SYM-NTH SYMBOL 196 135 0.70 North arrow symbol
GE-N-MAP-SYM-SCE SYMBOL 90 9 0.30 Symbol for source position
==============
Pit Layers
==============
GE-N-PIT-SYM-AUG SYMBOL 1 251 0.20 Symbol for borehole
GE-N-PIT-SYM-BAC SYMBOL 2 254 0.25 Test Pit Dug by Backhoe
GE-E-PIT-SYM-BED SYMBOL 110 9 0.30 Symbol for bed rock
GE-E-PIT-SYM-BLG SYMBOL 21 251 0.20 Symbol for building
GE-E-PIT-SYM-BUS BUSH 120 9 0.30 Symbol for bush
GE-E-PIT-SYM-CON SYMBOL 231 251 0.20 Symbol for coniferous
GE-E-PIT-SYM-DEC SYMBOL 241 251 0.20 Symbol for deciduous
GE-E-PIT-SYM-FAC SYMBOL 1 251 0.20 Symbol for pit face
GE-E-PIT-SYM-FEN FENCE 110 9 0.30 Fence
GE-E-PIT-SYM-HL SYMBOL 21 251 0.20 Symbol for power line
GE-E-PIT-SYM-HWY SYMBOL 91 251 0.20 Symbol for highway
GE-E-PIT-SYM-MAR SYMBOL 1 251 0.20 Symbol for marsh
GE-E-PIT-MISC-TC CONTINUOUS 100 9 0.30 Top of Pit Face
GE-E-PIT-MISC-TS GR-DRIVE 100 9 0.30 Toe of Slope
GE-N-PIT-MISC-LE CONTINUOUS 100 9 0.30 Limit of Extraction
GE-E-PIT-SYM-PIP SYMBOL 21 251 0.20 Symbol for pipeline
GE-E-PIT-SYM-RIV CONTINUOUS 130 9 0.30 Bank of River or Stream
GE-E-PIT-SYM-RR SYMBOL 1 251 0.20 Symbol for rail road
GE-E-PIT-SYM-SLO SYMBOL 120 9 0.30 Symbol for slope arrows
GE-E-PIT-SYM-STR SYMBOL 1 251 0.20 Symbol for structure
GE-E-PIT-SYM-TEL SYMBOL 1 251 0.20 Symbol for telephone line
GE-E-PIT-SYM-TWP GR-ROAD 40 9 0.30 Township road

app12-geotech Page 2 of 5
Pen
Full-Tone Plot
Layer LineStyle Weight Description
Color# Color#
(mm)
GE-N-PIT-TEXT-GRID CONTINUOUS 5 252 0.60 Title grid text
GE-N-PIT-TEXT-TLE CONTINUOUS 226 135 0.70 Title block text
GE-E-PIT-MISC-BNDP CONTINUOUS 6 135 0.70 Permit Boundary
GE-E-PIT-MISC-BNDS DASHED2 6 135 0.70 Permit Setback
GE-E-PIT-MISC-RAST CONTINUOUS 21 251 0.20 Raster Image
GE-E-PIT-SYM-GA CONTINUOUS 90 9 0.30 Gate
GE-E-PIT-MISC-SP GR-DRIVE 40 9 0.30 Stock Piles - Gravel Pits
GE-E-PIT-MISC-C1 CONTINUOUS 255 9 0.30 Contours - Primary
GE-E-PIT-MISC-C2 CONTINUOUS 251 253 0.20 Contours - Secondary
GE-E-PIT-MISC-T TEXT25 2 254 0.25 Contours Text
==============
Typical Layers
==============
GE-N-TYP-BASE-AT CONTINUOUS 1 251 0.20 Asphalt Treated Base
GE-N-TYP-BASE-CT CONTINUOUS 21 251 0.20 Cement treated base
GE-N-TYP-BASE-GRAN CONTINUOUS 231 251 0.20 Granular A Base
GE-N-TYP-BASE-GRO CONTINUOUS 241 251 0.20 Granular O
GE-N-TYP-BASE-OGD CONTINUOUS 1 251 0.20 Open graded drainage layer
GE-N-TYP-BASE-PCC CONTINUOUS 21 251 0.20 Portland Concrete Base
GE-N-TYP-BIN-HDB CONTINUOUS 90 9 0.30 Heavy duty binder course
GE-N-TYP-BIN-HL2 CONTINUOUS 100 9 0.30 HL-2 binder course
GE-N-TYP-BIN-HL3 CONTINUOUS 110 9 0.30 HL-3 binder course
GE-N-TYP-BIN-HL4 CONTINUOUS 120 9 0.30 HL-4 binder course
GE-N-TYP-BIN-HL8 CONTINUOUS 90 9 0.30 HL-8 binder course
GE-N-TYP-BIN-MDB CONTINUOUS 100 9 0.30 Medium Duty Binder Course
GE-N-TYP-BIN-RHM CONTINUOUS 110 9 0.30 Recycled Binder Course
GE-N-TYP-ERTH-CUT CONTINUOUS 1 251 0.20 Earth Cut
GE-N-TYP-ERTH-FIL CONTINUOUS 21 251 0.20 Earth Fill
GE-N-TYP-MISC-BT CONTINUOUS 231 251 0.20 Bituthene tape
GE-N-TYP-MISC-CB CONTINUOUS 241 251 0.20 Catch Basin
GE-N-TYP-MISC-CG CONTINUOUS 21 251 0.20 Curb and gutter
GE-N-TYP-MISC-DB CONTINUOUS 231 251 0.20 Dowel bar
GE-N-TYP-MISC-GEO CONTINUOUS 241 251 0.20 Geotextile
GE-N-TYP-MISC-GR CONTINUOUS 1 251 0.20 Guide rail

app12-geotech Page 3 of 5
Pen
Full-Tone Plot
Layer LineStyle Weight Description
Color# Color#
(mm)
GE-N-TYP-MISC-JT CONTINUOUS 90 9 0.30 Joint
GE-N-TYP-MISC-LTD CONTINUOUS 1 251 0.20 Load transfer device
GE-N-TYP-MISC-MH CONTINUOUS 21 251 0.20 Manhole
GE-N-TYP-MISC-MIL CONTINUOUS 231 251 0.20 Mill/coldplane
GE-N-TYP-MISC-RIP CONTINUOUS 241 251 0.20 Rip-rap
GE-N-TYP-MISC-R&F CONTINUOUS 100 9 0.30 Rout and Fill
GE-N-TYP-MISC-R&S CONTINUOUS 110 9 0.30 Rout and Seal
GE-N-TYP-MISC-SEW CONTINUOUS 1 251 0.20 Sewer
GE-N-TYP-MISC-SOD CONTINUOUS 21 251 0.20 Sod
GE-N-TYP-MISC-SUB CONTINUOUS 120 9 0.30 Sub Drain
GE-N-TYP-MISC-TAC CONTINUOUS 90 9 0.30 Tack coat
GE-N-TYP-MISC-TIE CONTINUOUS 1 251 0.20 Tie bar
GE-N-TYP-MISC-TPS CONTINUOUS 21 251 0.20 Topsoil
GE-N-TYP-SUB-CLR CONTINUOUS 231 251 0.20 Clear stone
GE-N-TYP-SUB-GRA CONTINUOUS 241 251 0.20 Granular A subbase
GE-N-TYP-SUB-GRB CONTINUOUS 1 251 0.20 Granular B subbase
GE-N-TYP-SUB-SSM CONTINUOUS 21 251 0.20 Select subgrade material
GE-N-TYP-SUBQ-ERTH CONTINUOUS 231 251 0.20 Earth Subgrade
GE-N-TYP-SUBQ-MUS CONTINUOUS 241 251 0.20 Muskeg
GE-N-TYP-SUBQ-ORG CONTINUOUS 1 251 0.20 Organics
GE-N-TYP-SUBQ-RK CONTINUOUS 21 251 0.20 Rock Subgrade
GE-N-TYP-SUBQ-RK-CUT CONTINUOUS 231 251 0.20 Rock Cut
GE-N-TYP-SUBQ-RK-FILL CONTINUOUS 241 251 0.20 Rock Fill
GE-N-TYP-SUBQ-STR CONTINUOUS 1 251 0.20 Rock Shatter
GE-N-TYP-SUBQ-SWP CONTINUOUS 21 251 0.20 Swamp
GE-N-TYP-SUBQ-WAT CONTINUOUS 143 8 0.40 Water
GE-N-TYP-SURF-CIP CONTINUOUS 90 9 0.30 Cold in place resurfacing
GE-N-TYP-SURF-DFC CONTINUOUS 100 9 0.30 DFC surface course
GE-N-TYP-SURF-GRA CONTINUOUS 1 251 0.20 Granular A surface
GE-N-TYP-SURF-HIP CONTINUOUS 110 9 0.30 Hot in place resurfacing
GE-N-TYP-SURF-HL1 CONTINUOUS 120 9 0.30 HL1 surface course
GE-N-TYP-SURF-HL3 CONTINUOUS 90 9 0.30 HL3 surface course
GE-N-TYP-SURF-HL4 CONTINUOUS 100 9 0.30 HL4 surface course
GE-N-TYP-SURF-MIC CONTINUOUS 110 9 0.30 Micro surfacing

app12-geotech Page 4 of 5
Pen
Full-Tone Plot
Layer LineStyle Weight Description
Color# Color#
(mm)
GE-N-TYP-SURF-OFC CONTINUOUS 120 9 0.30 OFC surface course
GE-N-TYP-SURF-PCC CONTINUOUS 90 9 0.30 Portland Concrete Surface
GE-N-TYP-SURF-RHM CONTINUOUS 100 9 0.30 RHM surface course
GE-N-TYP-SURF-ST CONTINUOUS 1 251 0.20 Surface treatment
GE-N-TYP-TEXT-GRID CONTINUOUS 5 252 0.60 Title grid text
GE-N-TYP-TEXT-TLE CONTINUOUS 6 135 0.70 Title block text

app12-geotech Page 5 of 5
MTO AutoCAD Standards Guide January 2004
Version 2004

APPENDIX A-13

LAYER STANDARDS

For

FOUNDATIONS DRAWINGS
FOUNDATIONS DESIGN LAYER DEFINITIONS
- January 2004 -

Application of the IES CAD Layer Standards


( AA-B-CCC-CC )

Discipline (AA): The following abbreviations are used:


FD - Foundation Design

Status (B): The following abbreviations are used:


N - New Construction G - General E - Existing F - Future R - Removal

Feature (CCC): The feature portion of the layer name is generally defined by a single component.

Associated Layer (CC): The following abbreviations are used:


(This layer is optional) T - Text D - Dimension P - Pattern RB - Rebar

app13-foundations Page 1 of 3
Pen
Full-Tone Plot
Layer LineStyle Weight Description
Color# Color#
(mm)
==============
Layers
==============
BORDER CONTINUOUS 6 135 0.70 Border - Frame - Title Block
DWGINFO CONTINUOUS 7 9 0.00 Drawing Info
VPORTS CONTINUOUS 4 8 0.00 View Ports
FD-E-BASE100-T SYMBOL 132 254 0.25 Sheet Scale = 100'
FD-E-BASE50-T SYMBOL 132 254 0.25 Sheet Scale = 50'
FD-E-CHART_FRAME SYMBOL 254 254 0.25 Sheet Border
FD-E-CHART_TEXT-T CONTINUOUS 132 254 0.25 Sheet Text
FD-E-CONEPLOT1 SYMBOL 92 254 0.25 Cone Graph On p.1
FD-E-CONEPLOT2 SYMBOL 92 254 0.25 Cone Graph On p.2
FD-E-CONEPLOT3 SYMBOL 92 254 0.25 Cone Graph On p.3
FD-E-CONEPLOT4 SYMBOL 92 254 0.25 Cone Graph On p.4
FD-E-CONEPLOT5 SYMBOL 92 254 0.25 Cone Grapg On p.5
FD-E-DESC1-T CONTINUOUS 2 254 0.25 Description Text On p.1
FD-E-DESC2-T CONTINUOUS 2 254 0.25 Description Text On p.2
FD-E-DESC3-T CONTINUOUS 2 254 0.25 Description Text On p.3
FD-E-DESC4-T CONTINUOUS 2 254 0.25 Description Text On p.4
FD-E-DESC5-T CONTINUOUS 2 254 0.25 Description Text On p.5
FD-E-ELEVSCAL1 SYMBOL 142 254 0.25 Elevation Text On p.1
FD-E-ELEVSCAL2 SYMBOL 142 254 0.25 Elevation Text On p.2
FD-E-ELEVSCAL3 SYMBOL 142 254 0.25 Elevation Text On p.3
FD-E-ELEVSCAL4 SYMBOL 142 254 0.25 Elevation Text On p.4
FD-E-ELEVSCAL5, SYMBOL 142 254 0.25 Elevation Text On p.5
FD-E-GNDWATER1 SYMBOL 212 254 0.25 Ground Water On p.1
FD-E-GNDWATER2 SYMBOL 212 254 0.25 Ground Water On p.2
FD-E-GNDWATER3 SYMBOL 212 254 0.25 Ground Water On p.3
FD-E-GNDWATER4 SYMBOL 212 254 0.25 Ground Water On p.4
FD-E-GNDWATER5 SYMBOL 212 254 0.25 Ground Water On p.5
FD-E-LOGO SYMBOL 254 254 0.25 MTO Logo
FD-E-SAMPLES1 SYMBOL 2 254 0.25 Soil Samples On p.1
FD-E-SAMPLES2 SYMBOL 2 254 0.25 Soil Samples On p.2
FD-E-SAMPLES3 SYMBOL 2 254 0.25 Soil Samples On p.3

app13-foundations Page 2 of 3
Pen
Full-Tone Plot
Layer LineStyle Weight Description
Color# Color#
(mm)
FD-E-SAMPLES4 SYMBOL 2 254 0.25 Soil Samples On p.4
FD-E-SAMPLES5 SYMBOL 2 254 0.25 Soil Samples On p.5
FD-E-VANES1 SYMBOL 2 254 0.25 Vanes On p.1
FD-E-VANES2 SYMBOL 2 254 0.25 Vanes On p.2
FD-E-VANES3 SYMBOL 2 254 0.25 Vanes On p.3
FD-E-VANES4 SYMBOL 2 254 0.25 Vanes On p.4
FD-E-VANES5 SYMBOL 2 254 0.25 Vanes On p.5

app13-foundations Page 3 of 3