Vous êtes sur la page 1sur 4

EU 1991-1-1 Loadings for Purlin & Girt

Dead loads
Self weight of section (CH 250) = 0.28 kN/m
Weight of the roof sheet 0.1x1.5 = 0.15 kN/m

Live loads
Load on sheeting 0.6x1.5 = 0.90 kN/m

Wind loads

Wind load in +X direction


Wind pressure = 0.50 kN/sqm
BASED ON NOTE 2 OF 7.2.9(6) EN 91-1-1 CPI = -0.3
External pressure for Teta = 0 DEGREE F = -1.7,G=-1.2 & H=-0.6
Wind Load in F Region (-1.7-0.3)*0.71 = -1.42 kN/sqm
Wind Load in G Region (-1.2-0.3)*0.71 = -1.07 kN/sqm
Wind Load in H Region (-0.6-0.3)*0.71 = -0.64 kN/sqm

Load in F region for 6m span = -8.52 kN/m


Load in G region for 7.535m span = -8.06 kN/m
Load in H region for 7.535m span = -4.82 kN/m

Applied load in staadpro = -8.52 kN/m

Wind load in -X direction

*EXTERNAL PRESSURE FOR TETA = 180DEGREE F = -2.3,G=-1.3 & H=-0.8


*WIND LOAD IN F REGION (-2.3-0.3)*0.71 = -1.633kN/sqm
*WIND LOAD IN G REGION (-1.3-0.3)*0.71 = -1.14kN/sqm
*WIND LOAD IN H REGION (-0.8-0.3)*0.71 = -0.781kN/sqm
e=11.8
EN 1991-1-1 LOADINGS FOR CCR BUILDING

1. Ground Beam (carries only the perimeter brick wall)

Wall height 4.0 m


Brick Wall 230 mm thk. 5.75 kN/m2 Density 25
Load applied to Ground Beam 23.0 kN/m

2. Roof Slab

Dead Loads
Finishes (water proofing & insulation board) 100 mm thk. 2.0 kN/m2 Density 20
Ceiling & Services 0.5 kN/m2
Imposed Dead Load 2.5 kN/m2
Roof RC slab 175 mm thk. 4.375 kN/m2 Density 25
Total Dead Load (incl.slab selfweight) 6.9 kN/m3
Live Loads
Imposed Live Load 0.0 kN/m2
Non-Accessible Roof 0.6 kN/m2
Total Imposed Load (Roof Slab) 0.600 kN/m2
Service Load
Total Service Load 7.475 kN/m2
Ultimate Load
Total Ultimate Load (1.35DL+1.5LL) 10.18 kN/m2

Roof (Periphery) Beam


Wall height 1.00 m
Brick Wall 230 mm thk. 4.6 kN/m2 Density 20
Load applied to Roof main beam 4.6 kN/m

Load From Cantilever Slab @ Roof Level


Span (L) 1500 mm
Thick slab 150 mm thk. 5.625 kN/m Density 25
Finishes/water proofing 50 mm thk. 1.500 kN/m Density 20
Ceiling & Services 0.075 kN/m
Parapet 230 mm thk. 4.600 kN/m Density 20
Parapet Ht. 1 m
Dead Load 11.80 kN/m

Imposed Live Load 0.9 kN/m


Applied Moment on Beam - Dead Load 8.85 kN.m/m
- Live Load 0.68 kN.m/m

Description
Sl No DL (kN/m2) LL(kN/m2)
At Ground Floor
1
At Roof
2 Air con-condensor 6.875 0.60