Ultimate Design Bending Moment for Long Slender Column/Pier/Pile

Mmax = 7108 kN-m


Ultimate axial force, Ned = 12790 kN Mmin/Mmax = 1
M,RD ---> Ultimate moment, M = 15132.58 kN-m Mmin = 7108 kN-m
Meqp = 1277 kN-m First order B.M. in quasi-permanent load combination in SLS
Column clear height, l = 37349 mm ( ,to) = 1 Final creep coefficient
Effective length factor, F = 1.5 d = h/2 + is = 1372.552 mm Effective depth (Refer eq. 11.8 of IRC:112-2011)
Effective length, le = Fl = 56023.5 mm First Order Moments
Initial Ecc. due to imperfection, e1 = 0 mm M01=Mmin+e1NEd = 7108 kN-m
M02=Mmax+e1NEd = 7108 kN-m
Slenderness, = lo/I = 131.82 rm=M01/M02 = 1.000
Slenderness limit llim=20ABC/ n = 19.899 15.4C/ n C=1.7-rm = 0.700
n = Ned/(Acfcd) = 0.293 Relative axial (normal) force
= Asfyd/(Acfcd) = 0.441 Mechanical reinforcement ratio
As : total area of reinforcement = 44220 mm^2 B = (1+2w) = 1.372
Ac : area of concrete cross-section = 2269800.7 mm^2 ef = ( ,to)Meqp/Med = 0.180 Effective creep ratio
fck : Charac.Compressive Strength = 40 N/mm^2 A = 1/(1+0.2 ef) = 0.965 (Refer Cl. 11.2.1 of IRC:112-2011)
fcd : Design Compressive Strength = 17.87 N/mm^2 nu = 1+w = 1.441
fyd : factored Design Strength of Reinf. = 434.8 N/mm^2 nbal = 0.4 Value of n at maximum moment of resistance
Es : Elsticity Modulus of Reinf. = 200 GPa Kr = (nu-n)/(nu-nbal) = 1 1 Correction factor depending on axial force
= 0.35+fck/200- /150 = -0.369 (Refer eq. 11.11 of IRC:112-2011)
K = 1+ ef = 1.000 1 Factor for taking account of Creep
Maximum curvature = 4.50119E-06 from analysis

1/r = Kr K (1/ro) = Kr K (fyd/Es0.45d) = 0.000


c = 9.870 Contant, for given moment distribution
e2 = (1/r) le / c = 1119.287
Moe = max(0.6M02+0.4M01,0.4M02) = 7108 kN-m (Refer eq. 11.5 of IRC:112-2011)
M2 = NEd e2 = 14315.686 kN-m Nominal second Order Moment (Refer eq. 11.5 of IRC:112-2011)
M0ed = 7108 kN-m
Med = 21423.686 kN-m
Med/Mmax = 3.014

Vous aimerez peut-être aussi