Vous êtes sur la page 1sur 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

LEGEND OF FINISHES

SPECIFICATION TABLE:
A A
FLOOR FINISHES
F1 - Trowel finish with Epoxy Coatings

A NORTH Y SECTION F2
F3
- False floor with Anti-Static PVC tiles finish on top
- Anti-Static PVC tiles
ELEVATION F4 - Anti-Slip Ceramic tiles with 100mm high skirting
(Acid / Chemical Resistant - Except Prayer, Ablution,
Kitchen, Toilet and Janitor Room)
F5 - Trowel finish with Heavy Duty Floor Hardener and
A A1 B B1 C D E E1 F G G1 H H1 H2 H3 J Chemical Resistant Epoxy coating
F6 - Cement render
64000 F7 - Carpet
B B
9000 7500 7500 8000 8000 7500 7500 9000 WALL FINISHES

X1
W1 - Plastered and Painted for Brickwall
3000 10000 7875 4125 7000 3000 4150 17850 4000 3000
- Painted only for R.C. Wall
3000 4500 4500 3000 2000 2000 2000 W2 - Ceramic tiles up to door frame height
W3 - 2100 mm high gypsum partition wall with acoustic
3 treatment to specialist detail and specification
CEILING FINISHES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
C1 - Fair-Faced and Painted NOTES
STAIR 2 C2 - Suspended Acoustic Ceiling (1200mm x 600mm)
C3 - Without Ceiling
C4 - Aluminium Strip Ceiling
C C5 - Moisture Resistant Ceiling (1200mm x 600mm) C

100dp
9 FLAT SLAB FLAT SLAB SKIRTING FINISHES
3000

S1 - 100mm high Anti-Static PVC tiles skirting


VOID S2 - 100mm high Ceramic tiles skirting
8a KIBLAT
292
50dp
50dp
GENERAL STORE HVAC
S3
S4
- 100mm high False Floor skirting (Aluminium)
- Without skirting

50dp
FRESH
9000

370dp

UTILITIES
MALE 50dp
LOADING OTR 102 AIR
PRAYER AREA (MCB 1 : OPZ 2) RISER - AUTOCLAVED AERATED CONCRETE BLOCK

50dp

50dp

50dp

50dp

50dp

50dp

50dp
150dp

ROOM 50dp
6000

ABLUTION. - R.C. WALL


150dp
MALE 50dp
TELECOM VOID
ROOM ELECTRICAL
TOILET ROOM UTILITIES - DRYWALL

50dp
JANITOR FEMALE TOILET ELEVATOR FLAT
- FALSE FLOOR
50dp

Ramp up 1 :8 SLAB
HR ELV ELEC
D 8 DOOR SCHEDULE D

Ramp dn
50dp

50dp
HR
D1 - 900mm x 2100mm (h) water resistant solid
3000

FLAT SLAB FLAT SLAB core timber


D2 - 1800mm x 2100mm (h) water resistant solid
7a core timber
7500

AREA MANAGER AREA MANAGER D3 - 750mm x 2100mm (h) 12mm thk. compact
ROOM OER ROOM high pressure laminated cubicle door
OER (OPA - 12) OER
4500

PANTRY (OPA - 13) OPA - 13


11000

OPA - 14 OPA - 12 D4 - 1000mm x 2100mm (h) water resistant solid


core timber
CORRIDOR
AREA D5 - 750mm x 2100mm (h) water resistant solid
7 AREA
MANAGER
ROOM
MANAGER
ROOM FD1A
core timber
- 900mm x 2100mm (h) Insulated 1 hour fire
(OPA - 14) (OPA - 11) CORRIDOR
E rated steel door E
FD2A - 900mm x 2100mm (h) Insulated 2 hours fire
rated steel door
7500

KIBLAT
FEMALE FD1B - 1800mm x 2100mm (h) Insulated 1 hour fire
PRAYER
292

rated steel door


50dp

ROOM
4000

SECTION X
100dp ABL.
X SECTION FD2B - 1800mm x 2100mm (h) Insulated 2 hour fire
rated steel door
150dp

OER OER
150dp

OPA - 15 FD1C - 1800mm x 2500mm (h) Insulated 1 hour fire


6 ADMIN
OPA - 11
OTR 101 FLAT SLAB rated steel door
ROOM (MCB 1 : OPZ 1) FD2C - 1800mm x 2500mm (h) Insulated 2 hours fire
OPC-1
4000

rated steel door


ADMIN FD1E - 1000mm x 2500mm (h) Insulated 1 hour fire
F
WEST D
ROOM
OPC-1 rated steel door
5a F
8000

FRS2A - 3000mm x 3000mm (h) 2 hours fire rated


ELEVATION
17 18 19 20 21 22 23 24 25 26
AREA MANAGER
DN STAIR 1 ROOM roller shutter
(OPA - 15)
4000

3 WAITING
ROOM
WINDOW SCHEDULE
WD1 - 1200mm x 1200mm 8mm thk. clear glass with dry film
HR EAST
64000

Ramp up 1 : 8
B tinted with sliding frame
5
16 15 14 13 12 11 10 9 8 7 6

AREA MANAGER
ROOM ELEVATION WD3 - 1200mm x 600mm 8mm thk. clear glass with dry film
tinted with alum. frame top hung
(OPA - 16)
WD4 - 2400mm x 2100mm 8mm thk. clear glass with
5500

GENERAL fixed alum. frame


MEETING UP
WD6 - 1200mm x 600mm 8mm thk. clear glass with
8000

ROOM
fixed alum. frame
10000

G WD7 - 1200mm x 1800mm 10mm thk. clear glass with G


4a HR
6 7 8 9 10 11 12 13 14 15 16
fixed alum. frame
2500

CORRIDOR OER OER WD8 - 1800mm x 600mm 8mm thk. clear glass with dry film
OPA - 16 OPA - 21 STAIR
3 tinted with alum. frame top hung
4 TOILET ACCESSORIES
1500

DN

26 25 24 23 22 21 20 19 18 17
WC - V.C. Water Closet with Cistern/Flush Valve c/w
Accessories.
3a FLAT SLAB SR - Chrome Plated Shower Rose.
7500

B - V.C. Wash Hand Basin with Chrome Plated


6000

AREA Water Tap & Accessories.


FUTURE AREA MANAGER ROOM
MANAGER ROOM (OPA - 21) SH - V.C. Wall Mounted Soap Dish.
TH - V.C. Wall Mounted Toilet Roll Holder.
H DOC & LIBRARY
(OPZ-2)
U - V.C. Urinal Bowl c/w Accessories. H
3 TAP - Chrome Plated Bip-Tap.
13000

FUTURE OER VENDOR/LICENSOR FT - Stainless Steel Floor Trap.


AREA MANAGER AREA MANAGER ROOM
OER ROOM OER ROOM OPA - 22 uFT - u.P.V.C. Floor Trap.
4500

(OPA - 23) OPA - 23 (OPA - 22) HB - Chrome Plated Hand Bidet c/w Accessories.
MIR - 6mm thk. 1st. Quality Mirror on 3mm thk.
7500

Waterproofed Plywood Backing with Aluminium


2a CORRIDOR
SWM
Framing.
- Sanitary Waste Disposal (Mercerizer).
3000

FLAT SLAB
HD - Automatic Hand Dryer.
HR
NOTES :
2
Digitally signed by Digitally signed by
Digitally signed by Irwan
Kanvinchelvan A/L
Dzafir Bin Sudirman Moghana Sundaram
Kanagarajah
Date: 2017.03.09 16:31:46 Date: 2017.03.09 Date: 2017.03.09 16:32:49
+08'00'
HR 16:32:19 +08'00' +08'00'

PRINTING/ ELEC. 1. All Dimensions are in Millimeter and all Levels are in Meter
I PHOTOCOPY/ ADMIN ADMIN UTILITIES INC. DIST. FLAT U.N.O. 3 09-MAR-17 IFC - ISSUED FOR CONSTRUCTION IRW MOG KAN I
SCANNING ROOM ROOM LOADING RM/ ROOM/ VISITOR SLAB
DOC & LIBRARY ROOM OPC-2 OPC-2 AREA RISER RISER ROOM CONFERENCE 2. Car Parking shall be allocated and develope by package 2 12-JAN-17 IFC - ISSUED FOR CONSTRUCTION SHJ MOG KAN
6000

(OPZ-1) ROOM VOID contractor. (nos. of car parks required - 60 car parks.
nos. of car parks provided - 76 car parks.) 1 15-JUL-16 IFC - ISSUED FOR CONSTRUCTION SHJ MOG KAN
9000

HVAC 3. Abbreviations :
FRESH
AIR S.O.P - Set Out Point
0 20-MAY-16 IFC - ISSUED FOR CONSTRUCTION SHJ MOG KAN
RISER
1a FLAT SLAB
VOID

FLAT SLAB
WC
S
- Water Closet
- Shower
C 31-MAR-16 IFR - ISSUED FOR REVIEW SHJ MOG KAN
B 29-JAN-16 IFR - ISSUED FOR REVIEW SHJ MOG KAN
3000

FFL - Finish Floor Level


FFLL - Finish Floor Lower Level A 30-NOV-15 IFR - ISSUED FOR REVIEW SHJ MOG KAN
1 EL - Elevation Level
100dp

X1 RS - Roller Shutter Door Rev Date Status - Revision Memo Written by Checked by Approved by
J AAC - Autoclaved Aerated Concrete Block J
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
4. Flat roof shall be designed and constructed with effective In accordance with Article 41 of the Conditions of Contract, the ownership in this document shall vest in OWNER. No part of this
STAIR 4
document may be reproduced, stored in a retrieval system or transmitted in any form or by any means (electronic, mechanical

SE
Water Proofing System to ensure no Leaking of Water.
photocopying, recording or otherwise) without the permission of OWNER.

CT
5. All HVAC Room walls shall be 250mm brick wall with finish

IO
and to be provided 2 nos. of floor traps. CONFIDENTIAL Not to disclose without authorization.

N
6. Package Contractor shall further confirm S.O.P. upon
Construction stage.
7. Room door size shall be further confirmed during detail
design with regard to Equipment size.
8. FLOOR FINISHES - All Toilets Floor and Wets Area Shall
C SOUTH Y SECTION Have 1 Layer of Brushbond Type Cementitious
OUI JV is a Consortium of Fluor Daniel International (Malaysia) Sdn Bhd and
Technip Geoproduction (M) Sdn Bhd PRPC Utilities and Facilities Sdn Bhd
Waterproofing Strictly to Manuf's Specs. & Requirement
K KIBLAT ELEVATION to Architect's Approval.
PETRONAS RAPID PROJECT, PENGERANG K
292
MCB FIRST FLOOR PLAN 9. CEILING FINISHES - All Ceiling Height Shall Be 3000mm
Height on both ground and first floor Unless Otherwise PACKAGE 14 - UTILITIES, INTERCONNECTING, OFFSITE UNITS
MAIN CONTROL BUILDING (6710-MCB-601) Stated.
10. All R.W.D.P. Shall Be (100mm,150mm, 200mm) with
Scale 1 : 200 Full Accessories Strictly to Manuf's Specs. & Requirement ARCHITECTURAL DRAWING
Unless Otherwise Stated.
11. Generally, the External Wall are Painted with Weather MAIN CONTROL BUILDING (6710-MCB-601)
Sheild Emulsion Paint to Architect's Approval.
12. False floor height shall be 800mm minimum except FIRST FLOOR PLAN
OTR Room shall be 600mm minimum.
13. Electrical information is preliminary, electrical room DOC. CLASS : X SCALE : 1 : 200 SHEET : 1 OF 1
dimension to be confirmed upon receiving vendor
L REVISION FORMAT
information. CONTRACTOR L
14. Trenches layout to refer M & E drawings. Doc. Ref.
RAPID-P0014-0007-ELE-DWG-6710-1036
15. Air Cooled Chillers layout to refer M & E drawings.
RAPID-P0014-0007-HVA-DWG-6710- 1001 & 1002.
OWNER
Doc. Ref.
RAPID - P0014 - 0007 - ARC - DWG - 6710 - 1103 3 A1
Project Package Originator Discipline Doc. Type Unit No Serial No

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Vous aimerez peut-être aussi