Vous êtes sur la page 1sur 3

ATTACHMENT 5

Pressure (barg) Temperature (C) Hydrate Difference Required


Phase Fuel Gas Sources Upstream Downstream Upstream Downstream Temperature Temperature Temperature to avoid Result
Valve Valve Valve Valve (C) (C) Hydrate (C)
Primary Normal Operation 74.5 31.0 20.1 -2.1 -21.6 19.5 -16.6 Will NOT Form
Settle-out Condition 140.0 31.0 29.4 -17.5 -21.6 4.0 -16.6 Will Form
Secondary
Export Condition 206.2 31.0 48.8 -9.3 -21.6 12.3 -16.6 Will NOT Form
Early Life-1
Gendalo-1020 Well 89.6 31.0 10.0 -20.3 7.8 -28.1 12.8 Will Form
Tertiary Gendalo-1130 Well 89.6 31.0 49.0 24.3 10.1 14.3 15.1 Will NOT Form
Maha Well 34.5 31.0 10.0 8.2 4.1 4.1 9.1 Will Form
Primary Outlet DPCU 74.5 31.0 17.6 -4.7 -21.6 16.9 -16.6 Will NOT Form
Settle-out Condition 139.4 31.0 29.4 -17.0 -21.6 4.6 -16.6 Will Form
Secondary
Export Condition 206.2 0.0 48.8 -9.3 -21.6 12.3 -16.6 Will NOT Form
Early Life-2 Gendalo-1020 Well 89.6 31.0 9.9 -20.3 7.8 -28.1 12.8 Will Form
Gendalo-1130 Well 89.6 31.0 49.0 24.3 10.3 14.0 15.3 Will NOT Form
Tertiary
Maha Well 34.5 31.0 10.0 8.2 4.2 4.0 9.2 Will Form
Gandang Well 89.6 31.0 10.0 -19.3 5.7 -24.9 10.7 Will Form
Primary Outlet DPCU 66.9 31.0 39.9 24.0 -21.2 45.2 -16.2 Will NOT Form
Settle-out Condition 124.9 31.0 29.4 -12.2 -21.2 8.9 -16.2 Will NOT Form
Secondary
Export Condition 183.7 31.0 48.8 -4.5 -21.2 16.6 -16.2 Will NOT Form
Mid Life Gendalo-1020 Well 34.5 31.0 9.9 8.0 6.0 1.9 11.0 Will Form
Gendalo-1130 Well 34.5 31.0 49.0 47.5 10.8 36.7 15.8 Will NOT Form
Tertiary
Maha Well 34.5 31.0 10.0 8.2 4.3 3.9 9.3 Will Form
Gandang Well 34.5 31.0 10.0 8.2 5.0 3.2 10.0 Will Form
Primary Normal Operation 66.9 31.0 39.2 23.5 -21.6 45.1 -16.6 Will NOT Form
Settle-out Condition 78.1 31.0 29.4 7.5 -21.6 29.1 -16.6 Will NOT Form
Secondary
Export Condition 105.1 31.0 48.7 19.4 -21.6 41.0 -16.6 Will NOT Form
Late Life Gendalo-1020 Well 34.5 31.0 9.8 7.9 6.2 1.7 11.2 Will Form
Gendalo-1130 Well 34.5 31.0 48.1 46.4 10.9 35.6 15.9 Will NOT Form
Tertiary
Maha Well 34.5 31.0 10.0 8.2 4.4 3.8 9.4 Will Form
Gandang Well 34.5 31.0 10.0 8.2 5.1 3.1 10.1 Will Form

Table 5.0-1: Hydrate Mitigation Results


Notes:
1. The secondary fuel gas source tends to form hydrate after the gas let down to 450 psig.
2. The Gandang wells are not online during early life-1.
3. If the difference temperature between operating and hydrate temperature is less than 5C (10F) then the hydrate is considered to form.
4. The settle-out pressure of secondary source during start up is estimated proportionally based on Interface data. The Interface data is presented in Attachment-9.
RESULT
PHASE OF LIFE
EARLY LIFE-1 EARLY LIFE-2 MID LIFE
FUEL GAS SOURCES Flag T (C) Flag T (C) Flag T (C)
Primary Outlet DPCU X 19.5 X 16.9 X 45.2
Export Condition O 4.0 O 4.6 X 8.9
Secondary Settle-out Condition X 12.3 X 12.3 X 16.6
Gendalo-1020 Well O -28.1 O -28.1 O 1.9
Gendalo-1130 Well X 14.3 X 14.0 X 36.7
Maha Well O 4.1 O 4.0 O 3.9
Tertiary Gandang Well - - O -24.9 O 3.2

Fuel Gas Source Mass rate (kg/h)


Secondary Settle-out 1
Tertiary Gendalo-1 12.5
LATE LIFE
Flag T (C)
X 45.1
X 29.1
X 41.0
O 1.7
X 35.6
O 3.8
O 3.1

Vous aimerez peut-être aussi