stopping ordinary
combustible, electrical, and flammable liquid fires before they can cause significant damage.
Safe for use where people are present. It removes heat and breaks up the fire at the molecular level. And because it
discharges as a gas, it leaves no residue and doesnt require costly clean-up like water or dry chemical systems. Perhaps
the most well respected and globally recognized of all clean agent fire suppressants, HFC-227ea applications range from
computer and electronic rooms to museums and military vehicles.
It effectively extinguishes Class B and C fires by cooling and smothering and it will not conduct electricity back to the
operator.
These rechargeable extinguishers have pressure gauges and require a 6-year maintenance and a 12-year hydrostatic test.
Clean Agent Fire Protection System, which includes the use of HFC-227ea and FM-200,
leaves no residue and doesnt require costly clean-up, unlike sprinklers and other fire protection
systems. And it discharges in 10 seconds or less, extinguishing a fire quickly and effectively.
Clean Agent Fire Suppression Systems are great in applications ranging from
telecommunications and data processing to switch gear rooms, military applications and cell sites
to high-tech medical applications. HFC-227ea fire suppression is also a widely accepted
replacement for Halon 1301.
DESCRIPTION
For speed in suppressing fires, reducing damages, , Fike is the clear choice. Our
Fikes Clean Agent System uses Fikes patented rupture disc valve design offering additional
flexibility, effectiveness and speed. That translates into minimal equipment / facility damage and
little or no business interruption.
Fikes
With a Fike designed fire protection system you can count on speed and efficiency in your fire
protection, and much more.
In addition, Fike can provide the system components and accessories to meet your complete
clean agent fire suppression system requirements. Intelligent control panels, delayed action
devices, early warning smoke detection, warning signs, manual releasing devices, automatic
detection and warning devices and fire alarm panels are all available from Fike.
APPLICATIONS
Computer rooms
Telecommunication centers
Records and data archives
Testing / imaging equipment
Reference material
Chemical laboratories
Clean rooms
Control rooms
Flammable liquid storage
Offshore drilling rigs
Robotic equipment
Textile manufacturing
Electric utility facilities
Media storage
Military vehicles
Art / artifacts / historical collections
Known for quality, dependable fire protection systems, Fike continues to look for ways to
improve the effectiveness of all its safety products. The Impulse Valve Technology greatly
improves the performance of clean agent fire suppression systems over mechanical valve
systems by combining the reliability and efficiency of a rupture disc with the flexibility of
electric actuation. Read more about our Impulse Technology.
DATA CENTERS
LE ARN MORE
TELECOMMUNICATIONS
LE ARN MORE
EDUCATION
LE ARN MORE
FINANCIAL INSTITUTIONS
LE ARN MORE
GOVERNMENT
LEARN MORE
HEALTH CARE
LEARN MORE
HOSPITALITY
LE ARN MORE
MUSEUMS/GALLERIES
LEARN MORE
POWER GENERATION
LEARN MORE
OFFICE BUILDING
Your LocationHome > Products > FIRE SYSTEMS > Gas Release Control System
Product Introduction
The JB-QBL-QM200 fire alarm control panel/agent releasing control panel is developed and manufactured by Fanhai
Sanjiang Electronics. As a fire alarm controller with a gas fire extinguishing function, JB-QBL-QM200 has some
functions and characteristics in full compliance with the requirements of national standards Fire Alarm Control Units
(GB4717-2005) and Automatic Control System for Fire Protection (GB16806-2006). The JB-QBL-QM200 can be
used with a local manual/auto control box, an emergency start/stop control box, a horn/strobe, a release indicator, an
agent drop display panel, a starting air cylinder, an extinguishant cylinder set and some other necessary items to form
a complete alarm and gas fire extinguishing control system. The JB-QBL-QM200 is mainly applied to the pipe
network type or non-pipe network type high/low pressure CO2 fire extinguishing system, FM-200
(heptafluoropropane) fire extinguishing system, foam fire extinguishing system, gas-aerosol fire extinguishing system,
IG541 (INERJEN) gas fire extinguishing system and other fire extinguishing systems using Halon alternatives
(haloalkane). It can be mounted with a common switching value detector to realize fire detection and alarm, and its
internal relay can control gas fire extinguishers as well as relevant alarm devices and linkages directly. It is
extensively applied in places like computer rooms, reference rooms, switchboard rooms, transformer rooms,
communication base stations, etc.
Product Features
1To connect detectors by 2 loops, and our variety of conventional smoke detectors and heat detectors ap
ply to JB-QBL-QM200..
2Its available to preset 0-
30seconds automatic delay for electromagnetic valve (electric detonator)
3To provide standalone output port for electromagnetic drive, and support 3A(24V)start
ing current.
4Keyboard lock password protection to prevent misoperation.
5To provide historical message record, and separately record alarm, trouble and agent-
releasing 999 messages for each
6All-
in trouble monitoring; gas extinguishing control panel recover automatically without man
ual operation after trouble is removed.
7To adopt low power consumption design, and standby power is available for 48hours c
ontinuous work.
8 Applications: Its applied in locations where electrical fire, solid surface fire, liquid su
rface fire and gas fire which can be cut off gas source may occur; it also matches with cab
inet-type or pipenet-
type heptafluoropropane extinguishing device, mixed gas extinguishing device IG541, S-
type aerosol extinguishing device and high-and-low pressure CO2 extinguishing device.
Technical Parameters
JB-QBL-QM200 fire alarm controller gas fire control controller is developed by the Shenzhen City, Sanjiang Electronics Co., Ltd. production and
production. It is a fire extinguishing function of the fire alarm controller, JB-QBL-QM200 features and characteristics in full compliance with national
standards GB4717-2005 "fire alarm controller" and GB16806-2006 "fire linkage control system" requirements, it and the scene Manual / automatic
switching control box, emergency start / stop switching control box, sound and light alarm, bleed indicator light, weightless display disk, start cylinder, fire
extinguisher bottle group composed of complete alarm and gas fire control system.
JB-QBL-QM200 is mainly used for a variety of pipe network or pipe network high / low pressure carbon dioxide fire extinguishing system, FM-
200 (heptafluoropropane) fire extinguishing system, foam fire extinguishing system, aerosol fire extinguishing system, IG541 (smoke) Systems and other
alternative halon (haloalkane) fire extinguishing systems. Can be connected to the ordinary switch detector, fire detection and alarm; through the
Model: JB-QBL-QM200
for a variety of pipe network or pipe network high / low carbon dioxide fire extinguishing system, heptafluoropropane fire extinguishing system, foam
fire extinguishing system, aerosol fire extinguishing system, smoke foaming fire extinguishing system and other alternative halon Of the fire extinguishing
system.
Features:
1, the use of improved code redundancy and digital de-noising technology for smoke density and temperature detection to ensure high stability of the
system;
2, the district control panel to provide a fire alarm output, composite fire alarm output function;
4, 0 to 39 seconds can be preset solenoid valve (squib) automatic start delay time, and providing a starting countdown;
5, low-power design system, backup power continuous working time of greater than 48 hours;
8, distinguished system failure, fire, gas discharge delay deflation of four states, namely, to give the corresponding The sound of light alarm.
Technical parameters:
System capacity: single area, two loops, the number of detectors per loop can be accessed <= 20 (common detector)
output circuit current limiting: solenoid valve drive output circuit: <= 3A, other drive output circuit: <= 1A
installation: wall-mounted