Document No.

FILTER A037-020-02-DS-1911
PROCESS DATA SHEET Rev. No. 1
Page 1 of 1
PROJECT LPG P/L FROM BPCR/HPCR TO URAN BOTTLING PLANT CLIENT BPCL, MUMBAI
UNIT URAN RECEIPT TERMINAL FOR URAN BOTTLING PLANT JOB NO. A037 UNIT NO. 020
ITEM NO. 020-GN-BK-101 A/B (1W+1S) SERVICE LPG
TYPE BASKET TYPE
OPERATING CONDITIONS
FLOW RATE
NORMAL M3/HR 264 - 281
MAXIMUM M3/HR 290 - 309 1
INLET PRESSURE KG/CM2G 16.5
INLET TEMPERATURE DEG C 16 - 37
ALLOWABLE PRESSURE DROP KG/CM2 0.2 (CLEAN) / 0.5(DIRTY)
SIZE OF PARTICLES TO BE REMOVED MICRON 100
FILTRATION EFFICIENCY 98%
FLUID PROPERTIES @ P & T
DENSITY KG/M3 569.1 -533.2
VISCOSITY CP 0.156 - 0.12 1
PRESENCE OF CORROSIVE COMPONENTS NIL
MECHANICAL DATA
DESIGN PRESSURE KG/CM2G 37.5 1
DESIGN TEMPERATURE DEG C 65
MATERIAL OF CONSTRUCTIO
BODY KCS
FILTER ELEMENT SS
CORROSION ALLOWANCE
BODY MM 3
FILTER ELEMENT MM NIL
NOZZLE DETAILS
SERVICE SIZE INCHES RATING REMARKS
INLET 10 D1A NOTE-5
OUTLET 10 D1A NOTE-5
VENT 2 D1A
DRAIN 2 D1A
UTILITY CONNECTION 2 D1A
FLUSHING CONNECTION -
SAFETY VALVE INLET -
NOTES
1. FOR DETAILS REFER TO P&ID NO. A037-02-41-010-1115.
2. FILTER ELEMENT MUST WITHSTAND A DIFFERENTIAL PRESSURE OF 3.0 KG/CM2 WITHOUT BREAKING OR FAILURE.
3. COMPANION FLANGE AT INLET AND OUTLET OF FILTER SHALL BE SUPPLIED BY VENDOR.
4. FILTER COVER (DOOR) SHALL BE QUICK OPENING / CLOSING TYPE. DOOR OPENING MECHANISM TO BE CONSTRUCTED
SUCH THAT THE DOOR CANNOT BE OPENED UNLESS THE FILTER IS FULLY DEPRESSURISED.
5. FILTER SHALL BE DESIGNED FOR A MAXIMUM FLOW RATE OF 350 TPH CORRESPONDING TO MAXIMUM THROUGHPUT
POSSIBLE WITH THE DIA, THICKNESS AND DESIGN CONDITIONS IN PIPELINE.INLET AND OUTLET NOZZLES SHALL BE
DESIGNED ACCORDINGLY. HOWEVER, THE PRESENT FLOW RATE SHALL BE 165 TPH.
6. DELETED. 1

1 29.04.2010 REVISED & ISSUED FOR ENGINEERING VSP VKP GA


0 13.04.2010 ISSUED FOR COMMENTS/ENGINEERING VSP VKP GA
Prepared Reviewed Approved
Rev. No. Date Purpose
By By By
Format No,3-0241-1011 Rev. 0 Copyrights EIL - all rights reserved