MANUAL
ACCESS
BLACK PRIMER
APPLICATOR Operation
3-WAY BALL VALVE POSITIONS (TOP VIEW)
7
4 Fill the Five-Gallon
Pressure Pot with Solvent
6
1. See Figure 1. Make sure that the ball valve (2) is in
5
the off position.
2. Close the flow control valve (8).
3. Adjust the air regulator (6) to 0 psi/bar. Pull on the
ring of the pressure relief valve (5) to relive pressure
from the pressure pot.
4. Unlock and remove the cover (7). Inspect the O-ring
on the cover for damage and replace if necessary.
5. Fill the pressure pot to the desired level. Install and
lock the cover (7).
6. Adjust the air regulator (6) to the desired pressure.
Figure 1 Typical Pressure Pot Components
7. Open the flow control valve (8).
Table 1 Components
Item Description 8. Turn the 3-way ball valve (2) to desired position
when necessary.
1 Manual access solvent line
2 Three-way balldirects solvent to either the
manual access or black primer applicator;
turns off solvent to the system Maintenance
3 Black primer applicator solvent line
4 Inline filterfilters solvent Refer to Table 2.
Parts
See Figure 2 and the following parts list.
6 1
16 2
17 3
15 4
5
FLOW
8
7
13 14
8
8
12
11 9
10
Figure 2 Parts
MANUAL ACCESS
PRESSURE
CONTROL
BALL VALVE
AIR SUPPLY
Notes: