ene oe
D2.5 Column Splices (SFRS columngigeeseeeane)
= When tension stress in butt joints with CJP welds
exceeds 0.3F,, use tapered transitions
* Stress based on flange of smaller column
* Tapered transition requirements found in AWS
D1.8 Clause 4.2
Tapered Also copies
transition per to columns of
AWS D1.8 unequal width
(4.2) Be eS emg
Eom ia
Ceca etd
| Gee tee
stress levelD2.5 Column Splices (all columns)
"Exceptions:
¢ If flanges and webs are joined using CJP
welds, splice may be located no closer to
beam-column connection than depth of
column
* Composite columns
Column splice located
closer than 4 ft. (but
no closer than d,) if
made with CJP welds
}) ASC Night School - Seismic Design ManualD2.5 Column Splices (all columns)
"All column splices shall be located 4 ft or
more from beam-to-column connections
= Exceptions: Locate at column mid-height if
clear height is less than 8 ft.
Column a: 4 ft or more
splice from connection
or at column
midheight