Vous êtes sur la page 1sur 3
ene oe D2.5 Column Splices (SFRS columngigeeseeeane) = When tension stress in butt joints with CJP welds exceeds 0.3F,, use tapered transitions * Stress based on flange of smaller column * Tapered transition requirements found in AWS D1.8 Clause 4.2 Tapered Also copies transition per to columns of AWS D1.8 unequal width (4.2) Be eS emg Eom ia Ceca etd | Gee tee stress level D2.5 Column Splices (all columns) "Exceptions: ¢ If flanges and webs are joined using CJP welds, splice may be located no closer to beam-column connection than depth of column * Composite columns Column splice located closer than 4 ft. (but no closer than d,) if made with CJP welds }) ASC Night School - Seismic Design Manual D2.5 Column Splices (all columns) "All column splices shall be located 4 ft or more from beam-to-column connections = Exceptions: Locate at column mid-height if clear height is less than 8 ft. Column a: 4 ft or more splice from connection or at column midheight