Vous êtes sur la page 1sur 46

ALARMLAR

VE
ZMLER

1
NDEKLER

1 Kabinet Software Seviyelerini Anlamak...................................................................................... 5


2 Hardware Kontrol......................................................................................................................... 6
2.1 Equipment ............................................................................................................................ 6
2.2 RBS 3418 RRU RET......................................................................................................... 7
2.3 CBU ve ETMFX kartlar...................................................................................................... 8
2.4 RAX ve TX kartlar.............................................................................................................. 9
2.5 TX ve OBIF........................................................................................................................ 10
3 RADIO Network ........................................................................................................................ 12
3.1 Radio Network Genel Grnm ........................................................................................ 12
3.2 Sektor Carrier Sinyalizasyon............................................................................................. 13
4 IP Transport.............................................................................................................................. 14
5 Alarm Event ve Loglar............................................................................................................ 15
5.1 Alarm List .......................................................................................................................... 15
5.2 Alarm Log .......................................................................................................................... 16
5.3 Event Log ........................................................................................................................... 17
5.4 OSS Alarm List Viever ...................................................................................................... 18
6 Alarm zm ........................................................................................................................... 19
6.1 Alarm inceleme ve zm................................................................................................. 20
6.1.1 OSS Alarm List - Grn ....................................................................................... 20
6.1.2 RNC de AMOS Grn.......................................................................................... 21
6.1.3 EMAS Grn ........................................................................................................ 22
6.2 CPI Alex dokmanlar ile Alarm zm....................................................................... 23
6.3 En ok Karlalan 10 Alarm ............................................................................................ 25
6.3.1 Ethernet Switch Port Fault ......................................................................................... 25
6.3.2 AuxPlugInUnit_CommunicationLostWithRet........................................................... 26
6.3.3 AntennaBranch_FeederCurrentTooLowInBranchA .................................................. 26
6.3.4 AuxPlugInUnit_CommunicationLostWithAsc .......................................................... 26
6.3.5 OpticalInterfaceLink_OpticalInterfaceLinkFailure ................................................... 27
6.3.6 UpLinkBaseBandPool_ULHWLessThanULCapacity ve
DownLinkBaseBandPool_DLHWLessThanDLCapacity.......................................................... 27
6.3.7 AntennaBranch_AntennaSystemProblemInBranchB ................................................ 27
6.3.8
AuxPlugInUnit_NewAuxiliaryUnitDetectedNotCorrespondingToTheDefinedConfigu
ration 28
6.3.9 RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit................................ 28
6.3.10 NbapCommon_Layer3SetupFailure........................................................................... 28
6.4 Node B RNC de Grlen Tipik Alarmlar ....................................................................... 28
6.4.1 Heartbeat failure......................................................................................................... 29
6.4.2 License Key Fault....................................................................................................... 29
6.4.3 AuxPlugInUnit_PiuConnectionLost .......................................................................... 29
6.4.4 DbccDevice_GammaDownLinkFailure..................................................................... 29
6.4.5 Carrier_NumberOfCarriersExceedsLicensedLimit.................................................... 29
6.4.6 Carrier_RejectSignalFromHardware.......................................................................... 29
6.4.7 Eul_NbapMessageFailure .......................................................................................... 29
6.4.8 Hsdsch_NbapMessageFailure .................................................................................... 30
6.4.9 ObifDeviceGroup_GammaLinkFailure ..................................................................... 30
2
6.4.10 Plug-In Unit General Problem.................................................................................... 30
6.4.11 Power Failure Left Slot .............................................................................................. 30
6.4.12 Rach_NbapMessageFailure........................................................................................ 30
6.4.13 RetDevice_RetFailure ................................................................................................ 30
6.4.14 TrDeviceSet_GeneralHWError.................................................................................. 31
6.4.15 UbchDeviceSet_GeneralSWError.............................................................................. 31
6.4.16 Utrancell_ExternalResourceUnavailable ................................................................... 31
6.4.17 Utrancell_NbapMessageFailure ................................................................................. 31
6.4.18 Utrancell_RBSLocalCellNotAdded ........................................................................... 31
6.4.19 Utrancell_ServiceUnavailable.................................................................................... 31
6.4.20 RruDeviceGroup_GammaLinkFailure....................................................................... 31
6.4.21 Emergency Unlock of Software Licensing ................................................................ 32
6.4.22 Utrancell_NbapReconfigurationFailure ..................................................................... 32

Appendix
Alarm and Event List Alarms ..............................................................................................33
Alarm and Event List Events .............................................................................................40
.

3
Alarm zebilmek iin;nce bize verilen bilginin-Alarmn deerlendirilmesi ,
Normal - olamas gereken deer ile karlatrlmas, varsa bal olduu dier
Alarm , bal olduu Hardware ve Software Seviyesine gre deerlendirilmesi
gerekir.

4
Bu kapsamda

1 Kabinet Software Seviyelerini Anlamak


Node B ler farkli SW seviyesinde alabiliyorlar bunu anlamak iin: Kabinete EMAS ile balanmak
gerekiyor
Software Upgrade package yada Software UP penceresinde listelenen paketlerden Active olan
paket ismine baklr

SW ad Seviyesi

CXP9012073/1_R11C07 P.6.1.0 (RBS 3418)


CXP9012073/1_R10AV/9 P6.1.0-13 (RBS 3206)
CXP9012959/1_R6BN/1 P.7.0.0 (RBS 3206)
CXP9012959/1_R6BN/3 P.7.0.1 (RBS 3206)
CXP9012959/1_R9AF03 P.7.0.2 (RBS 3206- RBS 3418)

SW seviyesine bal olarak ekran grnleri ve Men deki yerleri baz farkllklar
gsterebilir.

5
2 Hardware Kontrol
Node B Integration Basicsdeki kurallara uygun ekilde configure edilmi kabinetteki ekipman
grnleri

2.1 Equipment
Kapal hali

6
2.2 RBS 3418 RRU RET

7
2.3 CBU ve ETMFX kartlar

8
2.4 RAX ve TX kartlar

9
2.5 TX ve OBIF

10
11
3 RADIO Network

3.1 Radio Network Genel Grnm

12
3.2 Sektor Carrier Sinyalizasyon

13
4 IP Transport

14
5 Alarm Event ve Loglar

5.1 Alarm List

15
5.2 Alarm Log

16
5.3 Event Log

17
5.4 OSS Alarm List Viever

18
6 Alarm zm
Node B zerinde oluabilecek alarmlar ve zmleri Ericcson Customer Product Information
dosyalarnda (ALEX) ayrntlar ile belirtmektedir.

Node B alarm ve Event listesi

Alarmlar OSS zerinden Alarm List Viever veya Temip Maximo Optima gibi Raporlama
programlar ile ekilir.

rnek :

Temip Raporlama Programndan alnm bir rapor: Temip_040609_1840

Youn RNC ve RBS mdahalesinden sonra sadece 3 gn sonra alnm bir baka rapor:
Temip_070609_1910

Alarm zmnde :
Kabinet iinde ve dnda hangi ekipmanlarn hangi ekipmanlar ile balantili alt dikkate
alnarak zm yoluna gidilmelidir.

19
6.1 Alarm inceleme ve zm
Aadaki resimde MBW02R1 RNC ye bal olarak alan HALBA 3G Node B ile ilgili alarmlar
grlmektedir.

6.1.1 OSS Alarm List - Grn

Bu saha ile ilgili i emri Maximo zerinden alacak ve mudahale istenecektir.

Genel olarak alarmlara mdahale sreleri

Critical Alarm : Alarm 4-6 saat ierisinde zlmelidir.


Major Alarm : Alarm 24-36 saat ierisinde zlmelidir
Minor Alarm : Alarm 2- 7 gn ierisinde zlmelidir.
Warning : ilk saha ziyaretinde incelenmelidir.

Sahada birden fazla alarm olmas halinde en yksek ncelikli alarm dan balayarak tm alarmlar
giderilmelidir.

Baz durumlarda Alarm Event liste gre dk ncelik verilmi baz alarmlarn Node Bye ve
Network etkisi beklenenden daha yksek olabilmekte ve iemri ncelii ykseltilebilmektedir.

20
6.1.2 RNC de AMOS Grn

Alm iemrinde sahaya gitmeden mmknse operasyon merkezi ile irtibata geilerek sahada
mevcut olan TM alarmlar hakknda bilgi alnr.

Bu ilem OSS RNC zerinden AMOS denilen bir program ile yaplabilir.

Yukardaki resimde HALBA sahasna RNC ile balanmasndan sonra Node B zerinde grnen
alarmlar ve olas nedenleri sralanmaktadr.
Nr of active alarms are: 7
================================================================================================
Sever Specific Problem Cause Mo-Reference
================================================================================================
Maj AntennaBranch_AntennaSystemProblemInBranchB equipment_malfunction SectorAntenna=1,AntennaBranch=B
Maj AntennaBranch_AntennaSystemProblemInBranchB equipment_malfunction SectorAntenna=3,AntennaBranch=B
Maj AntennaBranch_FeederCurrentTooLowInBranchA equipment_malfunction SectorAntenna=1,AntennaBranch=A
Maj AntennaBranch_FeederCurrentTooLowInBranchA equipment_malfunction SectorAntenna=3,AntennaBranch=A
Maj AuxPlugInUnit_CommunicationLostWithRet equipment_malfunction SectorAntenna=1,AuxPlugInUnit=2
Maj AuxPlugInUnit_CommunicationLostWithRet equipment_malfunction SectorAntenna=3,AuxPlugInUnit=2
Maj OpticalInterfaceLink_OpticalInterfaceLinkFailure equipment_malfunction OpticalInterfaceLink=2-UL
>>> Total: 7 Alarms (0 Critical, 7 Major)

Yukaridaki resimde Ayrca Sahann IP adreside yeralmaktadr


Alarm bilgileri ve olas nedenleri (Cause) incelendiinde cihaz arzas olduu grlyor.
Saha ziyareti kanlmaz.
21
6.1.3 EMAS Grn
Saha ziyareti yapmadan , adres, irtibat, sahaya giri bilgileri kontrol edilir.
Ayrca gerekli olabilecek malzemeler ve bilgisayar alnr.
Node B ye balanabilmek iin sahann IP adresi ve gerekli olabilecek Username Password temin
edilir.
Kabinete Node B_Integration Basic te anlatlan ayarlar yaplarak balanlr.
Alarm List ten Alarmlar , oluma tarihleri ve Hangi ekipmandan geldiklerine dair ayrntl bilgi
bulunur.

Okunan alarm tanmlar , olas nedenleri ,ekipmanlar ve bazende kabinetin SW seviyelerine bal
olarak alarm zme yollar izlenir.

22
6.2 CPI Alex dokmanlar ile Alarm zm

Ericsson Node B iin ngrd btn alarmlar ve olas zm yontemlerini kabinet tiplerine gre
ayrm ve Herbir kabinet tipi iin Urn , Montaj, Yedekparca, Bakm Arza bilgilerini ieren Alex
dosyalar hazrlamtr.

23
Hemen her alarm iin, ilgili alarmlar, Alarm loglarda neler grlecei, Bu alarmn dzeltilmesi iin
neler yaplmas gerektii ayrntlar ile anlatlmtr.

24
6.3 En ok Karlalan 10 Alarm
Aada Hazirann ilk haftasnda NodeB kaynakl alarmlardan enok karlalanlar sralanmtr.

Alarm DeffinitionText # pc Where


Ethernet Switch Port Fault 919 RBS
AuxPlugInUnit_CommunicationLostWithRet 297 RBS
AntennaBranch_FeederCurrentTooLowInBranchA 248 RBS
AuxPlugInUnit_CommunicationLostWithAsc 238 RBS
OpticalInterfaceLink_OpticalInterfaceLinkFailure 134 RBS
UpLinkBaseBandPool_ULHWLessThanULCapacity 111 RBS
DownLinkBaseBandPool_DLHWLessThanDLCapacity 82 RBS
AntennaBranch_AntennaSystemProblemInBranchB 66 RBS
AuxPlugInUnit_NewAuxiliaryUnitDetectedNotCorrespondingToTheDefinedConfigurati
on 60 RBS
RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit 50 RBS

6.3.1 Ethernet Switch Port Fault


Bu alarm Node B zerinde ETMFX montaj ve gerekli tanmlamalar yapldktan sonra gelen
alarmlardandr.
ETMFX kart zerinde farkl portlardan gelebilir.

4 nolu port:
Bilgisayar EMAS ile Lokalden Node Bye balantnn yapld porttur. Bu porttan alarm
gelmesi, lokal fiziksel balantnn yaplmad anlamna gelir. Operasyonel anlamda bir sorun
tekil etmemektedir ve bu alarm iin i emri retilmemektedir. Alarmn giderilmesi iin 4 nolu
port EMAS ile yada RNC den bloklanabilir ve sonrasnda. Bu bloklama herhangi bir soruna
neden olmayacaktr.

5 nolu port:
Genellikle 3418 kabinetler iin kullanlan 4,5,6 sektrlerin yerald 2. RBS 3418 iin gerekli
olan transmisyon k - kaskat balantnn yapld porttur. Sahaya gelen transmisyon
balants 6 nolu porta girmektedir ve 5. Porttan alnan kaskat, 2. Kabinete 6 nolu porttan
girmektedir. Bu alarm, kaskat balantnn henz yaplmad anlamna gelebilir. Bu alarmn
giderilmesi iin 2. Kabinetin ilavesi beklenmelidir. Eer bu port bloklanrsa 2. Kabinet almaz.

6 nolu port:
Sahaya gelen transmisyon balantsnn girildii porttur.
Bu porttan gelen alarmn bilinen 2 nedeni vardr. Birincisi, normalde 100Mbit Full Duplex
olarak ayarlanm olmas gereken balantnn Transmisyon ekipmanlarnda (TAN-Router)
10Mbit olarak tanmlanmasdr veya Half Duplex- Full Duplex tanmlamasndaki bir hatadr. Bu
durumda TAN tarafndaki tanmlamalar kontrol edilmelidir ( aksiyon TN). kinci durum ise
Sahadaki Transmisyon ekipman (ML TN-NPU3-ETU2) ile kabinet arasnda yanl kablo tipinin
kullanlmasdr. TAN tarafndaki tanmlar doru ise sahada transmisyon kablo kontrol
gerekmektedir.

25
6.3.2 AuxPlugInUnit_CommunicationLostWithRet

Bu alarm Anten siteminde sk olarak kullanlan RET ekipman ile balant sorunlar yaanmas
halinde ortaya kar. Hem Makro kabinetler (RBS 3206-3106-3216-3116) hem de Main Remote
kabinetler (RBS 3418- 3518) karlalan bir alarmdr.
Makro kabinetlerde
RBS 3206-3106-3216-3116 gibi Makro NodeB kabinetlerde RET gerekli olan enerjiyi cabinet
ierisindeki RU FU kartlarndan Coaksiyel Feeder kablolar zerinden alr. RET in beslenmesi
ve kontrol edilmesi iin Feeder zerinde ASC yada RUI montaj yaplm olmaldr.
Arzann zm iin ;nce ASC RUI ile ilgili bir alarm olup olmad control edilir. Varsa bu
alarm zlr. Daha sonra RET ile ASC-RUI arasndaki data enerji kablosu kontrol edilir.
Gevek ise sklr, Arzal ise deitirilir.
Main Remote kabinetler
RBS 3418- 3518 gibi Main Remote kabinetlerde RRU zerindeki AUX EXT k ile RET
arasndaki data enerji kablosu kontrol edilir. Gevek ise sklr, Arzal ise deitirilir.

6.3.3 AntennaBranch_FeederCurrentTooLowInBranchA
Bu alarm NodeBye Site Equipment Script ile tanmlamas yaplan Feeder kabloya ait zayflama
(Attenuation) ve gecikme (Delay) deerlerinin Node B tarafndan (ASC-RU-RRU) llen
deerlerle karlatrmas ve farkl kmas durumunda retilen bir alarmdr.
Bu alarmn zm Kabinet tipine gore farkllk gsterir
Makro kabinetlerde
RBS 3206-3106-3216-3116 gibi Makro NodeB kabinetlerde ve tm SW seviyelerinde (P6.1.0,
P7.01, P7.02 gibi) RU dan balayarak Antene kadar olan kablolarn fiziksel kontrolu, DTF,
SWR, Insertion Loss testlerinin tekrarlanmas , varsa ASC alarmlar ile birlikte incelenirvarsa
arzalar dzeltilir.Testler sonunda hesaplanan gecikme ve zayflama deerleri ile Kabinet
zerinde tanmlanan deerler karlatrlr gerekiyorsa llen deerlere gre gncellenir.
Bunun yannda Antenna Supervision deerlerinin Site Equipmentte doru girildii kontrol edilir
Antenna Supervision deerleri aadaki tabloya gre dzenlenmi olmaldr
BRANCHA Indoororsharedfeeder 0
Others 10
BranchB IndoororsharedfeederorASCexisting 0
Others 80
Main Remote kabinetler
RBS 3418 -3518 kabinetlerde P7.0.2 seviyesine kadar bu alarm SWden kaynaklanan bir hata -
FAKE bir alarmdr. Eer sahada sadece bu alarm varsa mdahale etmeye gerek yoktur.

6.3.4 AuxPlugInUnit_CommunicationLostWithAsc
Bu alarm Anten siteminde sk olarak kullanlan ASC ekipman ile balant sorunlar yaanmas
halinde ortaya kar. Hemen tum Makro kabinetler (RBS 3206-3106-3216-3116) ile baz Main
Remote kabinet (RBS 3418- 3518) kullanlan anten sistemlerinde karlalan bir alarmdr.

RBS 3206-3106-3216-3116 gibi Makro NodeB kabinetlerde Mobil kullancdan gelen RX


sinyallerini kuvvetlendirmek ve Feeder kaybn en aza indirmek iin ASC kullanlr. ASC almas
iin gerekli olan enerjiyi kabinet ierisindeki RU FU kartlarndan Coaksiyel Feeder kablolar

26
zerinden alr. FU zerindeki ANT A k ASC iin gerekli olan enerji ve control sinyallerinin
alnd konnektordur.
Arzann zm iin ;nce kabinet ierisinde RU FU ile ilgili bir alarm olup olmad kontrol
edilir. Varsa bu alarm zlr. FU - ASC arasndaki Jumper ve Feeder kablolar kotrol edilir. A ve B
kollarnn doru ulara balandii kontrol edilir. Konnektrler control edilerek Gevek ise sklr,
Arzal ise deitirilir.
Site Equipmentde girilen Antenna Supervision deerleri aadaki tabloya gre dzenlenmi
olmaldr
BRANCHA Indoororsharedfeeder 0
Others 10
BranchB IndoororsharedfeederorASCexisting 0
Others 80

6.3.5 OpticalInterfaceLink_OpticalInterfaceLinkFailure
Sadece Main Remote kabinetlerde karlalabilecek bir alarmdr.
Remote unite RRU tayaca data ve Kabinet ii haberleme bilgilerini Main Uniteye Fiber optic
kablolar ile tar.
Optical Interface Link Failure alarm ncelikle ok hassas ve krlgan olan Fiberoptik kablo olmak
zere ; OBIFB kart kart zerinde yeralan SFP konnektor , Optik kablo, ve RRU zerinde yeralan
SFP konnektor ekipmanlarndan bir yada birkann hasarl krk yada kullanlamaz halde olduu
anlamna gelir.
Montaj esnasnda Fiberoptik kablo konnektorlerine dokunarak kirletmekte sk karlalan sorun
kaynaklarndandr
Eer sahadaki tm sektrlerden bu alarm geliyorsa OBIF kartnda problem olabilir. Bu durumda
ncelikli olarak bu karta restart atlmas denenmelidir. Bu restart sorunu zmezse OBIF kart arzal
olabilir yada RRU montaj yaplp yaplmad , OPTK kablolarda krk olup olmad tekrar
control edilmelidir.

6.3.6 UpLinkBaseBandPool_ULHWLessThanULCapacity ve
DownLinkBaseBandPool_DLHWLessThanDLCapacity
Yukardaki iki alarm da kapasite ile ilgili alarmlardr ve RAX-TX kartlarndaki problemler
nedeniyle tetiklenen alarmlardr. Sahann devreye alnmas esnasnda Site Equipment yklenmemi
kabinette grlebilirler. Ayn zamanda RU ve RRU ile ilgili problemlerde de bu alarm gelebilir.
Arzann gideriminde nce kabinete monte edilmi olan RAX ve TX kartlar detayl olarak incelenir.
Sorunlu olduu belirlenen ekipmana restarttan sonu alnamazsa sahaya genel restart denenebilir.
Lisans eksiklii, Uplink iin gerekli EUL Resource ve Downlink iin gerekli HS Resource
deerleri kullanlan kart tiplerine gre RNC ile karlkl kontrol edilir. Dzelmemesi durumunda bu
saha Ericssona iletilmelidir.

6.3.7 AntennaBranch_AntennaSystemProblemInBranchB
FU zerindeki ANT B kna bal olan kablodaki bir feeder kablo hatas durumunda karlalr.

27
Bunun yannda InBuildig sistemlerinde sadece ANT A k kullanldndan yanllkla B k
iinde Antenna Supervision deeri girilmesi durmunda bu hata ile karlaslr.
Arzann gideriminde nce Antenna Spervision parametreleri kontrol edilir. Daha sonra FU ile
Anten arasndaki feeder sistemi gzle control edilir. DTF VSWR testleri tekrarlanarak arzal
ksmlar deitirilir.

6.3.8 AuxPlugInUnit_NewAuxiliaryUnitDetectedNotCorrespondingToTheDefin
edConfiguration
zellikle sahadan, Montaj Arza personeli tarafndan SW upgradei yaplm kabinetlere daha
sonra SW yklemesine ihtiya duyan (hemen tm kartlar) yeni bir kart veya ekipman ilave
edilmesinden sonra grlr. En ok Montaj ve Upgrade ilemi bitmi sahalara daha sonra ASC -
RET montaj yapldktan sonra grlr.
Arzann gideriminde; RNC OSS te kullanlmakta olan bir FTP server zerine gerekli SW
Upgrade paketleri bulundurularak zmlenebilir.
Yada ;sahaya gidilerek Active durumdaki SWUpgrade paketi zelliklerine properties ile girilir.
Arza personelinin bilgisayarnda FTP server program alarak SW Upgrade paketibi barndran
folder ve File part bilgileri gncellenir. Daha sonra Install PIU Type seceneginden Kartn product
kodu secilerek gerekli SW yklenir. Backup alnarak Restart verilir. SWnin yeni taklan karta
yklenerek Kartn aktif hale gelmesi 15-20dak bulabilir.

6.3.9 RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit
Node B zerine montaj yaplm tm HWin uygun O&M, Site Equipmet ve Iub ile dzenlenmesi
gereklidir. Bu HWin alabilmesi iin NodeBye uygun zelliklere sahip lisansnda yklenmesi
gerekir.
Bu alarmn giderilmesinde RNC ile konuarak gerekli Lisansdosyalarnn yuklenip yuklenmedii.
RAX ve TX kartlarnda , Uplink iin gerekli EUL Resource ve Downlink iin gerekli HS
Resource deerleri kullanlan kart tiplerine gre uygun deerlerde ve lisans deeriniamayacak
ekilde ayarland kontrol edilir.

6.3.10 NbapCommon_Layer3SetupFailure
pmNoiseFloor adndaki bir countern dolmas sonucu reyen bir alarmdr. Gncel duruma gre bu
counter, NodeB tarafndaki tanmlamalardan karlmtr. Buna ramen daha once tanmlanp
tranmisyonu zun srekesik kalan sahalardan gelebilecek bir alarmdr.
Bu alarmn giderilmesinde; RNC ile konusarak ilgili Counterin RBS ten silinmesi ve backup alp
restart atarak alarm kaldrmas istenir.

6.4 Node B RNC de Grlen Tipik Alarmlar

Aadaki alarmlar ounlukla Node B alarmlardr. lerinde RNC tarafndan da grlen alarmlar
vardr.
Aklamalar RNCde alsan kiiler iin yazlmtr.

28
6.4.1 Heartbeat failure
Bu alarm 2Mbit balants ile ilgilidir ve bu alarma santral tarafnda alnabilecek bir aksiyon
bulunmamaktadr. Aksiyon TN

6.4.2 License Key Fault


Sahadan gelen bir alarmdir. Lisans yklemesi yaplmadn belirtir. SMO araclyla lisans
ykleyerek bu alarm giderebiliriz. Eer lisans yoksa lisans dosyasnn OSSe eklenmesi iin
aksiyon ENKya yazlr.

6.4.3 AuxPlugInUnit_PiuConnectionLost
lgili HW iin ncelikle santral tarafndan genel bir kontrol gereklidir. Genel bir alarmdr. Uygun
olmayan SW ieren veya Uygun olmayan ekilde sklm bir kartn slotundan bu alarm gelebilir.
Ulalan bulgulara gre BOya aksiyon verilebilir.
Carrier_RxDiveristyLost

lgili sektrn anten ekipmanlarna restart atmak denenmelidir. Sonu alnamazsa sahaya genel
restart atlabilir.

6.4.4 DbccDevice_GammaDownLinkFailure
Tx kaynakl bir problem olmas muhtemeldir. lk mdahale olarak sorunlu grnen TX kartna
restart atlmaldr. Bu mdahale sorunu zmezse RUIF e restart atlmaldr. Restartlar ile bir
sonu alamyorsak nce TX, sonra da RUIF(3206)/OBIF(3418) iin HW test balatmak
gerekmektedir. Sorun yine tekrarlarsa sahaya backup alp test ieren genel restart (cold restart with
test) atlmaldr. Eer problem yine devam ediyorsa bu durum Ericssona bildirilip kart deiimi
istenmelidir. Kart deiimi de sorunu gidermezse CSR aarak Ericssondan zm beklenmelidir.

6.4.5 Carrier_NumberOfCarriersExceedsLicensedLimit
Bu alarm, lisans ykl olmayan sahaya P7.0.2 SW seviyesine upgradeden kaynaklanmaktadr.
Upgrade yaplan sahaya upgradee uygun lisans yklenerek bu alarm giderilebilir. Eer gerekli
lisans OSSte mevcut deilse Ericssondan talep edilmelidir.

6.4.6 Carrier_RejectSignalFromHardware
Alarm aklamasnda belirtilen sektrn anten ekipmanndan (RRU, RU-FU vs.) kaynaklanan
problemdir. Aklamada belirtilen ekipmana restart atlmaldr. lk restart ie yaramazsa 2. Ve 3.
Restartlar denenebilir. Ekipman restartlar ie yaramazsa sahaya genel restart atlmaldr. Problem
devam ediyorsa SW paketi ile lisans uyumsuzluundan kaynaklanma ihtimali vardr. Bu durum
Ericssona yneltilmelidir.

6.4.7 Eul_NbapMessageFailure
RNCde reyen bir alarmdr. lgili sahann EUL kanallarnn almamas nedeniyle oluur.
ncelikli olarak NodeB tarafnda lisans kontrol yaplmaldr. EUL ieren bir lisans ykl olmaldr.

29
Eer lisans olup da almama durumu varsa HS ve EUL kaynaklar kontrol edilmelidir ve kabinet
tipine gre olmas gereken deerlere ayarlanmaldr. Bu dzeltmeye ramen EUL almazsa, RNC
tarafnda Iub datas ierisinde olmas gereken Edch MOsu tanmlanmam olabilir. Bu MO da
tantlp halen sorun devam ediyorsa NodeBde HW kontrol yaplmaldr.

6.4.8 Hsdsch_NbapMessageFailure
lgili sahann HS kanal tanmlar kontrol edilmelidir. Tanmlarda sorun yoksa RAX-TX kartlarnda
problem olabilir. Bu kartlar iin genel kontrol gereklidir.

6.4.9 ObifDeviceGroup_GammaLinkFailure
OBIF kartna restart atmak denenmelidir. Sonu alnamazsa sahaya genel restart denenebilir. Tekrar
sonu alnamazsa OBIF deiimi gerekebilir.

6.4.10 Plug-In Unit General Problem


lgili HW iin ncelikle santral tarafndan genel bir kontrol gereklidir. Genel bir alarmdr, ayrntl
inceleme gerektirir.

6.4.11 Power Failure Left Slot


Bu alarm iin sahann santral tarafndan genel kontrol gereklidir. Sahaya BO kontrol gerekebilir.

6.4.12 Rach_NbapMessageFailure
RNCde reyen bir alarmdr. lgili sahann Rach kanallarnn almamasna iaret eder. Bu durum,
NodeB tarafnda RAX kartndaki arzadan kaynaklanabilir. Kabinetteki kartlar kontrol edilmelidir.
RaxDeviceGroup_GeneralSWError

NodeBde reyen bir alarmdr. RAX kartndan kaynaklanmaktadr. lk mdahale olarak bu alarmn
geldii slottaki RAX kartna restart atlmaldr. Sorun devam ederse fcleanff yntemi
uygulanabilir ve ardndan sahaya restart atlmaldr. Halen problem devam ediyorsa aadaki
alarmlardan herhangi birinin daha olup olmad kontrol edilmelidir. Eer bunlardan biri varsa,
alarmlarn fake olma ihtimali vardr ve bu sorun SW upgrade ile zlecektir. Bu durumdaki sahay
Ericssona bildiriniz.

6.4.13 RetDevice_RetFailure
lgili sektrn RET ekipmannda sorun bulunmaktadr. ncelikle bu ekipmana restart denenmelidir.
Sonu alnamazsa RETin bal olduu RU-RRU ekipmanna restart denenebilir. RETi force
calibration ile yeniden kalibre etmek ie yarayan zmlerdendir.Yine de sonu alnamazsa RET
deiimi gerekebilir.

30
6.4.14 TrDeviceSet_GeneralHWError
TX kartnda veya RRU ekipmannda HW bir problem olumutur. Alarm ierii incelenerek
problemin olutuu kart,ekipman vs. deiimi iin sahaya ekip ynlendirilmelidir.

6.4.15 UbchDeviceSet_GeneralSWError
RAX kartnda oluan bir problemdir. Bu karta restart atarak sonu alnamazsa sahaya genel restart
denenebilir. Eer sorun halen devam ediyorsa yukarda bahsedilen fake alarm trnde bir alarm
olma ihtimali yksektir. P7.0.2 SW upgrade ile pekok sahada giderilebilmektedir .

6.4.16 Utrancell_ExternalResourceUnavailable
NodeBdeki NbapCommon_Layer3SetupFailure alarmnn RNCde tetikledii bir alarmdr.
NodeB tarafndaki alarm giderildikten sonra bu alarm da kalkmaktadr.

6.4.17 Utrancell_NbapMessageFailure
RNCde reyen bir alarmdr. lgili sahada kesik olan sektr/sektrlerden gelmektedir. Saha
incelenerek NodeB zerindeki alarma gre gerekli aksiyonlar alnmaldr.

6.4.18 Utrancell_RBSLocalCellNotAdded
RBS ve RNCdeki sektr tanmlamalar arasndaki uyumazlktan kaynaklanmaktadr. Saha 4 sektr
olmas gerekirken NodeB tarafnda 3418 tipinde 2. Kabinetin bulunmamas bu duruma bir rnektir.
Bu alarma neden olabilecek baka bir durum ise, Cell ID bilgilerinin RNC ve RBSte farkl
olmasdr. Bu bilgi iki tarafta da ayn olmaldr. RNC ve NodeB tarafinda control edilmelidir.
NodeB tarafnda ancak Site equipmentin silinip tekrar yklenmesi ile giderilebilir..

6.4.19 Utrancell_ServiceUnavailable
Bu alarm RNCde remektedir ve ilgili sahann tamamnn kesik olduunu belirtmektedir. Bu
durumda ncelikle RNCden sahann Iubsinin alp almad kontrol edilmelidir. Eer Iub
DISABLED durumdaysa 2 ihtimal szkonusudur. Ya RBS tarafnda Iub ykl deildir, ya da
transmisyon kaynakl bir kesinti vardr. Iub ykl deilse yklenerek bu alarmn kalkmas
beklenmektedir. Eer transmisyon kaynakl bir kesinti sz konusuysa bu durumdaki saha ilgili
transmisyon ekibine bildirilmelidir. emri Transmisyon ekibine iletilir.
Sahada HW kaynakl bir probleme rastlanrsa olumu soruna gre aksiyon alnr.

6.4.20 RruDeviceGroup_GammaLinkFailure
Belirtilen sektrn RRU ekipmannda sorun bulunmaktadr. ncelikle bu RRUya restart
denenmelidir. RRUya mdahale sonu vermezse srayla OBIF ve TX kartlarna restart atmak
denenebilir. Eer ana MO ENABLED durumda olup da alt MOlar DISABLED olarak
grnyorsa RRU toplayacak demektir. Ksa bir sre ierisinde tm MOlarn ENABLED
duruma gelmesi beklenmektedir. Tm mdahalelere ramen hibir MO ENABLED olarak
grnmyorsa RRU deiimi gerekmektedir.

31
6.4.21 Emergency Unlock of Software Licensing
Emergency lisans aktif edilmi bir sahadan gelen alarmdr. Bu lisans her bir saha iin 2 kere 1
haftalk olmak zere aktif edilebilir ve bu 1 haftalk sre iinde tm featurelar kullanlabilir. Bu
sre bitiminde saha trafiinin tamam ya da nemli bir ksm kapanabilir. Bu durumdaki bir saha
Ericssona bildirilmelidir ve i emri Ericssona ynlendirilmelidir.

6.4.22 Utrancell_NbapReconfigurationFailure
lgili sahann performans dklnden dolay oluan bir uyardr. RNC tarafndaki parametre
deiiklikleri ile dzeltilebilir.
Bu problemin nedeni, RNC tarafnda ilgili hcre iin tanmlanm transmisyon g deerinin RBS
tarafnda girilen feeder uzunluklar, delay ve attenuation deerlerine gre hesaplanm transmisyon
gc bilgisinin maksimum ve minimum snrlar dnda kalmasdr.

Bu sorunu zerken RBS tarafndaki bilgi referans alnp, RNC tarafna bu deerin girilmesi
gerekmektedir.

32
APPENDIX: Alarm and Event List - Alarms

Alarm and Event List


15/006 51-HRB 105 102/1 Uen

specificProblem eventType probableCause perceivedSeverity Managed Object


VC ete Alarm Indication Signal Comm ALARM_INDICATION_SIGNAL WARNING Aal0TpVccTp
VC ete Loss of Connectivity Comm TRANSMISSION_ERROR MAJOR Aal0TpVccTp
VC ete Remote Defect Indication Comm FAR_END_RECEIVER_FAILURE WARNING Aal0TpVccTp
VC ete Alarm Indication Signal Comm ALARM_INDICATION_SIGNAL WARNING Aal1TpVccTp
VC ete Loss of Connectivity Comm TRANSMISSION_ERROR MAJOR Aal1TpVccTp
VC ete Remote Defect Indication Comm FAR_END_RECEIVER_FAILURE WARNING Aal1TpVccTp
VC ete Alarm Indication Signal Comm ALARM_INDICATION_SIGNAL WARNING Aal2PathVccTp
VC ete Loss of Connectivity Comm TRANSMISSION_ERROR MAJOR Aal2PathVccTp
VC ete Remote Defect Indication Comm FAR_END_RECEIVER_FAILURE WARNING Aal2PathVccTp
VC ete Alarm Indication Signal Comm ALARM_INDICATION_SIGNAL WARNING AAl5TpVccTp
VC ete Loss of Connectivity Comm TRANSMISSION_ERROR MAJOR AAl5TpVccTp
VC ete Remote Defect Indication Comm FAR_END_RECEIVER_FAILURE WARNING AAl5TpVccTp
Accu_CircuitBreaker1Tripped Env FUSE_FAILURE MAJOR Accu
Accu_CircuitBreaker2Tripped Env FUSE_FAILURE MAJOR Accu
Accu_CircuitBreaker3Tripped Env FUSE_FAILURE MAJOR Accu
Accu_CircuitBreaker4Tripped Env FUSE_FAILURE MAJOR Accu
Accu_CircuitBreaker5Tripped Env FUSE_FAILURE MAJOR Accu
Accu_CircuitBreaker6Tripped Env FUSE_FAILURE MAJOR Accu
Accu_ClimateCircuitBreakerTripped Env FUSE_FAILURE MAJOR Accu
Accu_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR Accu
Accu_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR Accu
Accu_LossOfMains Eq COMMERICAL_POWER_FAILURE MAJOR Accu
Accu_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR Accu
Accu_VaristorFault Eq EQUIPMENT_MALFUNCTION MAJOR Accu
AcDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR AcDeviceSet
AcDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR AcDeviceSet
AiDevice_ExternalUnitFailure Eq EQUIPMENT_MALFUNCTION MAJOR AiDevice
AiDevice_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR AiDevice
AiDevice_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR AiDevice
AiDevice_LnaFailure Eq EQUIPMENT_MALFUNCTION MAJOR AiDevice
AiDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR AiDeviceSet
AiDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR AiDeviceSet
AiuDeviceGroup_DpProgramNotConfigured ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR AiuDeviceGroup
AiuDeviceGroup_ExternalUnitFailure Eq EQUIPMENT_MALFUNCTION MAJOR AiuDeviceGroup
AiuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR AiuDeviceGroup
AiuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR AiuDeviceGroup
AiuDeviceGroup_LossOfSynch Eq LOSS_OF_SYNCHRONISATION MAJOR AiuDeviceGroup
AiuDeviceGroup_MpDbCommunicationFailure Eq EQUIPMENT_MALFUNCTION MAJOR AiuDeviceGroup
AiuDeviceGroup_PoorClockSignal Eq TIMING_PROBLEM_M3100 MAJOR AiuDeviceGroup
AiuDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR AiuDeviceGroup
AiuDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR AiuDeviceGroup
AiuDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR AiuDeviceGroup
AiuDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR AiuDeviceGroup
AiuDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR AiuDeviceGroup
AiuDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR AiuDeviceGroup
AlmDevice_ExternalAlarm NotUsed NOT_USED NOT_USED AlmDevice
AlmDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR AlmDeviceSet
AlmDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR AlmDeviceSet
AntennaBranch_AntennaProblemInBranchA Eq EQUIPMENT_MALFUNCTION MAJOR AntennaBranch
AntennaBranch_AntennaProblemInBranchB Eq EQUIPMENT_MALFUNCTION MAJOR AntennaBranch
AntennaBranch_AntennaSystemProblemInBranchA Eq EQUIPMENT_MALFUNCTION MAJOR AntennaBranch
AntennaBranch_AntennaSystemProblemInBranchB Eq EQUIPMENT_MALFUNCTION MAJOR AntennaBranch
AntennaBranch_FeederCurrentTooHighInBranchA Eq EQUIPMENT_MALFUNCTION MAJOR AntennaBranch
AntennaBranch_FeederCurrentTooHighInBranchB Eq EQUIPMENT_MALFUNCTION MAJOR AntennaBranch
AntennaBranch_FeederCurrentTooLowInBranchA Eq EQUIPMENT_MALFUNCTION MAJOR AntennaBranch
AntennaBranch_FeederCurrentTooLowInBranchB Eq EQUIPMENT_MALFUNCTION MAJOR AntennaBranch
AscDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR AscDeviceGroup
AscDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR AscDeviceGroup
AscDeviceGroup_RetPortCurrentTooHigh Eq EQUIPMENT_MALFUNCTION MAJOR AscDeviceGroup
AscDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR AscDeviceGroup
Loss of Cell Delineation Comm LOCAL_NODE_TRANSMISSION_ERROR MAJOR AtmPort
AuxPlugInUnit_CableDisconnectedFromControllingPiu Eq EQUIPMENT_MALFUNCTION MAJOR AuxPlugInUnit
AuxPlugInUnit_CommunicationLostWithAsc Eq EQUIPMENT_MALFUNCTION MAJOR AuxPlugInUnit
AuxPlugInUnit_CommunicationLostWithRet Eq EQUIPMENT_MALFUNCTION MAJOR AuxPlugInUnit
AuxPlugInUnit_GeneralSwError Eq SOFTWARE_ERROR MAJOR AuxPlugInUnit
AuxPlugInUnit_LossOfMains Eq COMMERICAL_POWER_FAILURE MAJOR AuxPlugInUnit
AuxPlugInUnit_NewAuxiliaryUnitDetectedNotCorrespondingToTheDefEq UNAVAILABLE WARNING
inedConfiguration AuxPlugInUnit
AuxPlugInUnit_PiuConnectionLost Eq EQUIPMENT_MALFUNCTION MAJOR AuxPlugInUnit
BbifBoard_ClockDistributionMalfunction Eq CLOCK_SYNCHRONISATION_PROBLEM MAJOR BbifBoard
BbifBoard_GammaLinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR BbifBoard
BbifBoard_MpNpuCommunicationFailure Eq EQUIPMENT_MALFUNCTION MAJOR BbifBoard
BbifBoard_NpuConnectionLost Eq EQUIPMENT_MALFUNCTION MAJOR BbifBoard
BfDevice_BatteryChargingFailure Eq EQUIPMENT_MALFUNCTION MAJOR BfDevice
BfDevice_BatteryMissing ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR BfDevice
BfDevice_BatteryVoltageSupervisionTooLowMainLoadDisconnected Eq EQUIPMENT_MALFUNCTION MAJOR
BfDevice
BfDevice_BatteryVoltageSupervisionTooLowPrioLoadDisconnected Eq EQUIPMENT_MALFUNCTION MAJOR
BfDevice
BfDevice_DcDistributionFailure Eq EQUIPMENT_MALFUNCTION MAJOR BfDevice
BfDevice_HighOperatingTemperatureSupervisionTooHighMainLoadD Eq EQUIPMENT_MALFUNCTION MAJOR
isconnected BfDevice
BfDevice_LowBatteryCapacity Eq BATTERY_CHARGING_FAULT MINOR BfDevice
BfDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR BfDeviceSet
BfDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR BfDeviceSet
Bfu_BatteryChargingFailure Eq EQUIPMENT_MALFUNCTION MAJOR Bfu
Bfu_BatteryVoltageSupervisionTooLowMainLoadDisconnected Eq EQUIPMENT_MALFUNCTION MAJOR Bfu
Bfu_BatteryVoltageSupervisionTooLowPrioLoadDisconnected Eq EQUIPMENT_MALFUNCTION MAJOR Bfu
Bfu_DcDistributionFailure Eq EQUIPMENT_MALFUNCTION MAJOR Bfu
Bfu_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR Bfu

Alarm and Event List - Alarms 33 / 46


APPENDIX: Alarm and Event List - Alarms

Bfu_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR Bfu


Bfu_HighOperatingTemperatureSupervisionTooHighMainLoadDiscon Eq EQUIPMENT_MALFUNCTION MAJOR
nected Bfu
BfuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR BfuDeviceGroup
BfuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR BfuDeviceGroup
BfuDeviceGroup_HwSwMismatch ProcErr VERSION_MISMATCH MAJOR BfuDeviceGroup
Carrier_DbccDeviceNotPossibleToRelease ProcErr UNDERLYING_RESOURCE_UNAVAILABLE MAJOR Carrier
Carrier_DualModeNotSupported ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Carrier
Carrier_FrequencyBandNotSupported ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Carrier
Carrier_GainTooHigh ProcErr VARIABLE_OUT_OF_RANGE MAJOR Carrier
Carrier_GainTooLow ProcErr VARIABLE_OUT_OF_RANGE MAJOR Carrier
Carrier_MaxDlPowerCapabilityOutOfRange ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Carrier
Carrier_NoCommonChannelSupport ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Carrier
Carrier_NumberOfCarriersExceedsLicensedLimit QoS UNAVAILABLE MAJOR Carrier
Carrier_PowerClassTruncated ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR Carrier
Carrier_RejectSignalFromHardware ProcErr MESSAGE_NOT_EXPECTED MAJOR Carrier
Carrier_RxDiversityLost QoS PERFORMANCE_DEGRADED MAJOR Carrier
Carrier_RxRelationBbToAntennaRefOutOfRange ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Carrier
Carrier_SignalNotReceivedWithinTime ProcErr TIMEOUT_EXPIRED MAJOR Carrier
Carrier_TooLargeDlGainDifference ProcErr VARIABLE_OUT_OF_RANGE MAJOR Carrier
Carrier_TxBranchFailure QoS PERFORMANCE_DEGRADED MAJOR Carrier
ClDevice_ActiveCoolerFanFault Env COOLING_FAN_FAILURE MAJOR ClDevice
ClDevice_ActiveCoolerFault Env COOLING_SYSTEM_FAILURE MAJOR ClDevice
ClDevice_DcInputVoltageFault Eq EQUIPMENT_MALFUNCTION MAJOR ClDevice
ClDevice_ExternalFanFault Env COOLING_FAN_FAILURE MAJOR ClDevice
ClDevice_HeaterFault Eq EQUIPMENT_MALFUNCTION MAJOR ClDevice
ClDevice_InternalFanFault Env COOLING_FAN_FAILURE MAJOR ClDevice
ClDevice_LossOfMains Eq COMMERICAL_POWER_FAILURE MAJOR ClDevice
ClDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR ClDeviceSet
ClDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR ClDeviceSet
Clu_ActiveCoolerFanFault Env COOLING_FAN_FAILURE MAJOR Clu
Clu_ActiveCoolerFault Env COOLING_SYSTEM_FAILURE MAJOR Clu
Clu_DcInputVoltageFault Eq EQUIPMENT_MALFUNCTION MAJOR Clu
Clu_ExternalFanFault Env COOLING_FAN_FAILURE MAJOR Clu
Clu_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR Clu
Clu_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR Clu
Clu_HeaterFault Eq EQUIPMENT_MALFUNCTION MAJOR Clu
Clu_InternalFanFault Env COOLING_FAN_FAILURE MAJOR Clu
Clu_LossOfMains Eq COMMERICAL_POWER_FAILURE MAJOR Clu
CluDeviceGroup_EnclosureDoorOpen Env ENCLOSURE_DOOR_OPEN_M3100 MAJOR CluDeviceGroup
CluDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR CluDeviceGroup
CluDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR CluDeviceGroup
CluDeviceGroup_HwSwMismatch ProcErr VERSION_MISMATCH MAJOR CluDeviceGroup
CuDeviceGroup_AdConverterFailure Eq EQUIPMENT_MALFUNCTION MAJOR CuDeviceGroup
CuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR CuDeviceGroup
CuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR CuDeviceGroup
CuDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR CuDeviceGroup
CuDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR CuDeviceGroup
CuDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR CuDeviceGroup
CuDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR CuDeviceGroup
CuDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR CuDeviceGroup
CuDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR CuDeviceGroup
DbccDevice_GammaDownlinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR DbccDevice
DbccDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR DbccDeviceSet
DbccDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR DbccDeviceSet
DbchDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR DbchDeviceSet
DbchDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR DbchDeviceSet
DeviceGroup_AtmConfigurationMismatch ProcErr VERSION_MISMATCH MAJOR DeviceGroup
DeviceGroup_BackplaneBusCollision ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR DeviceGroup
DeviceGroup_ClockDistributionMalfunction Eq CLOCK_SYNCHRONISATION_PROBLEM MAJOR DeviceGroup
DeviceGroup_ConfigurationMismatchWithAntennaEquipment ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR DeviceGroup
DeviceGroup_DpProgramNotConfigured ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR DeviceGroup
DeviceGroup_EnclosureDoorOpen Env ENCLOSURE_DOOR_OPEN_M3100 MAJOR DeviceGroup
DeviceGroup_EulRequiresHsCodeResourcesInBbPool ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR DeviceGroup
DeviceGroup_ExternalUnitFailure Eq EQUIPMENT_MALFUNCTION MAJOR DeviceGroup
DeviceGroup_FanFailure Eq EQUIPMENT_MALFUNCTION MAJOR DeviceGroup
DeviceGroup_GammaDownlinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR DeviceGroup
DeviceGroup_GammaLinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR DeviceGroup
DeviceGroup_GammaUplinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR DeviceGroup
DeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR DeviceGroup
DeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR DeviceGroup
DeviceGroup_HwNotSupported ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR DeviceGroup
DeviceGroup_HwSwMismatch ProcErr VERSION_MISMATCH MAJOR DeviceGroup
DeviceGroup_IncompatibleGammaBusProtocol ProcErr SOFTWARE_ERROR MAJOR DeviceGroup
DeviceGroup_LossOfSynch Eq LOSS_OF_SYNCHRONISATION MAJOR DeviceGroup
DeviceGroup_MpDbCommunicationFailure Eq EQUIPMENT_MALFUNCTION MAJOR DeviceGroup
DeviceGroup_NumberOfHwEntitiesMismatch ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR DeviceGroup
DeviceGroup_NumberOfProcessingResourcesNotSupported ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR DeviceGroup
DeviceGroup_PoorClockSignal Eq TIMING_PROBLEM_M3100 MAJOR DeviceGroup
DeviceGroup_RaxTxInterfaceCommunicationError Eq EQUIPMENT_MALFUNCTION MAJOR DeviceGroup
DeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR DeviceGroup
DeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR DeviceGroup
DeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR DeviceGroup
DeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR DeviceGroup
DeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR DeviceGroup
DeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR DeviceGroup
DeviceGroup_TxTxCommunicationError Eq EQUIPMENT_MALFUNCTION MAJOR DeviceGroup
DigitalCable_Disconnected Eq EQUIPMENT_MALFUNCTION MAJOR DigitalCable
DownlinkBaseBandPool_DlHwLessThanDlCapacity ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR DownlinkBaseBandPool
Looped Link Comm TRANSMISSION_ERROR WARNING E1PhysPathTerm
PDH Alarm Indication Signal Comm ALARM_INDICATION_SIGNAL WARNING E1PhysPathTerm
PDH Degraded Signal Comm DEGRADED_SIGNAL_M3100 MINOR E1PhysPathTerm
PDH Loss of Frame Comm LOSS_OF_FRAME MAJOR E1PhysPathTerm
PDH Loss of Signal Comm LOSS_OF_SIGNAL MAJOR E1PhysPathTerm
PDH Remote Defect Indication Comm FAR_END_RECEIVER_FAILURE WARNING E1PhysPathTerm
PDH RNCI Comm REMOTE_NODE_TRANSMISSION_ERROR WARNING E1PhysPathTerm

Alarm and Event List - Alarms 34 / 46


APPENDIX: Alarm and Event List - Alarms

Looped Link Comm TRANSMISSION_ERROR WARNING E1PhysTerm


Looped Link Comm TRANSMISSION_ERROR WARNING E1Ttp
PDH Alarm Indication Signal Comm ALARM_INDICATION_SIGNAL WARNING E1Ttp
PDH Degraded Signal Comm DEGRADED_SIGNAL_M3100 MINOR E1Ttp
PDH Loss of Frame Comm LOSS_OF_FRAME Major E1Ttp
PDH Loss of Signal Comm LOSS_OF_SIGNAL MAJOR E1Ttp
PDH Remote Defect Indication Comm FAR_END_RECEIVER_FAILURE WARNING E1Ttp
PDH RNCI Comm REMOTE_NODE_TRANSMISSION_ERROR WARNING E1Ttp
PDH Alarm Indication Signal Comm ALARM_INDICATION_SIGNAL WARNING
E3PhysPathTerm
PDH Degraded Signal Comm DEGRADED_SIGNAL_M3100 MINOR
E3PhysPathTerm
PDH Loss of Frame Comm LOSS_OF_FRAME Major E3PhysPathTerm
PDH Loss of Signal Comm LOSS_OF_SIGNAL MAJOR E3PhysPathTerm
PDH Payload Mismatch Comm PAYLOAD_TYPE_MISMATCH MAJOR E3PhysPathTerm
PDH Remote Defect Indication Comm FAR_END_RECEIVER_FAILURE WARNING E3PhysPathTerm
PDH Unequipped Defect Comm SIGNAL_LABEL_MISMATCH WARNING E3PhysPathTerm
EDbchDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR EDbchDeviceSet
EDbchDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR EDbchDeviceSet
EScDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR EScDeviceSet
EScDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR EScDeviceSet
Ethernet Switch Port Fault QoS LINK_FAILURE MAJOR EthernetSwitchModulePort
Ethernet Switch Port Fault QoS LINK_FAILURE Major EthernetSwitchPort
Equipment Protection Hardware Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR ExchangeTerminal
ET Hardware Fault Eq REPLACEABLE_UNIT_PROBLEM MAJOR ExchangeTerminal
ExternalTma_LnaDegradedInBranchA Eq EQUIPMENT_MALFUNCTION MINOR ExternalTma
ExternalTma_LnaDegradedInBranchB Eq EQUIPMENT_MALFUNCTION MINOR ExternalTma
ExternalTma_LnaFailureBranchA Eq EQUIPMENT_MALFUNCTION MAJOR ExternalTma
ExternalTma_LnaFailureBranchB Eq EQUIPMENT_MALFUNCTION MAJOR ExternalTma
Auto-Configuration of Board Not Possible Eq UNAVAILABLE WARNING Fan
Auxiliary Unit Processor HW Fault Eq PROCESSOR_PROBLEM_M3100 MAJOR Fan
Auxiliary Unit Processor SW Fault ProcErr SOFTWARE_ERROR MINOR Fan
Fan Air Temperature Extremely High Env COOLING_FAN_FAILURE MAJOR Fan
Fan Ambient Temperature High Env COOLING_FAN_FAILURE WARNING Fan
Fan Ambient Temperature Low Env COOLING_FAN_FAILURE WARNING Fan
Fan Ambient Temperature Sensor Failure Env COOLING_FAN_FAILURE MAJOR Fan
Fan Ambient Temperature Too High Env COOLING_FAN_FAILURE MAJOR Fan
Fan Ambient Temperature Too Low Env COOLING_FAN_FAILURE MAJOR Fan
Fan Contact Fault Env COOLING_FAN_FAILURE MAJOR Fan
Fan HW Fault Env COOLING_FAN_FAILURE MAJOR Fan
Fan Power Redundancy Fault Env COOLING_FAN_FAILURE MINOR Fan
Fan Supervision Failure Env COOLING_FAN_FAILURE MAJOR Fan
Fan Supervision Redundancy Fault Env COOLING_FAN_FAILURE MINOR Fan
Fan SW Fault Env COOLING_FAN_FAILURE MAJOR Fan
Fan to Fan Cable Fault Env COOLING_FAN_FAILURE MINOR Fan
Left Fan Stopped Env COOLING_FAN_FAILURE MAJOR Fan
Right Fan Stopped Env COOLING_FAN_FAILURE Major Fan
FanDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR FanDeviceGroup
FanDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR FanDeviceGroup
FanDeviceGroup_LeftFanSpeedTooLow Env COOLING_FAN_FAILURE MINOR FanDeviceGroup
FanDeviceGroup_RightFanSpeedTooLow Env COOLING_FAN_FAILURE MINOR FanDeviceGroup
FanDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR FanDeviceGroup
FanDeviceGroup_SupplyAirTemperatureAbnormallyHigh Env HEATING_OR_VENTILATION_OR_COOLING_SYS MINOR
TEM_PROBLEM FanDeviceGroup
FanDeviceGroup_SupplyAirTemperatureAbnormallyLow Env HEATING_OR_VENTILATION_OR_COOLING_SYS MINOR
TEM_PROBLEM FanDeviceGroup
FanDeviceGroup_SupplyAirTemperatureExceptionallyHigh Env HEATING_OR_VENTILATION_OR_COOLING_SYS MAJOR
TEM_PROBLEM FanDeviceGroup
FanDeviceGroup_SupplyAirTemperatureExceptionallyLow Env HEATING_OR_VENTILATION_OR_COOLING_SYS MAJOR
TEM_PROBLEM FanDeviceGroup
FanDeviceGroup_SupplyAirTemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MAJOR FanDeviceGroup
Fast Ethernet Link Fault Eq REPLACEABLE_UNIT_PROBLEM MAJOR FastEthernet
FcuDeviceGroup_EnclosureDoorOpen Env ENCLOSURE_DOOR_OPEN_M3100 MAJOR FcuDeviceGroup
FcuDeviceGroup_FanFailure Eq EQUIPMENT_MALFUNCTION MAJOR FcuDeviceGroup
FcuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR FcuDeviceGroup
FcuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR FcuDeviceGroup
FcuDeviceGroup_HwSwMismatch ProcErr VERSION_MISMATCH MAJOR FcuDeviceGroup
FcuDeviceGroup_NumberOfHwEntitiesMismatch ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR FcuDeviceGroup
FuDeviceGroup_ConfigurationMismatchWithAntennaEquipment ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR FuDeviceGroup
FuDeviceGroup_ExternalUnitFailure Eq EQUIPMENT_MALFUNCTION MAJOR FuDeviceGroup
FuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR FuDeviceGroup
FuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR FuDeviceGroup
FuDeviceGroup_HwSwMismatch ProcErr VERSION_MISMATCH MAJOR FuDeviceGroup
GammaCable_CableWronglyConnected ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR GammaCable
GammaCable_GammaDownlinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR GammaCable
GammaCable_GammaUplinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR GammaCable
Gigabit Ethernet Link Fault Eq REPLACEABLE_UNIT_PROBLEM MAJOR GigaBitEthernet
HG-AIS Comm ALARM_INDICATION_SIGNAL WARNING HgTtp
HG-BAIS Comm FAR_END_RECEIVER_FAILURE WARNING HgTtp
HG-REC Comm LOSS_OF_MULTI_FRAME MAJOR HgTtp
HsDbchDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR HsDbchDeviceSet
IMA Config Aborted at Far End Comm REMOTE_NODE_TRANSMISSION_ERROR MAJOR ImaGroup
IMA Group Blocked at Far End Comm REMOTE_NODE_TRANSMISSION_ERROR MAJOR ImaGroup
IMA Group Configuration Aborted Comm LOCAL_NODE_TRANSMISSION_ERROR MAJOR ImaGroup
IMA Group Insufficient Links Comm LOCAL_NODE_TRANSMISSION_ERROR MAJOR ImaGroup
IMA Group Insufficient Links at Far End Comm REMOTE_NODE_TRANSMISSION_ERROR MAJOR ImaGroup
IMA Group Start-Up at Far End Comm REMOTE_NODE_TRANSMISSION_ERROR MAJOR ImaGroup
IMA Group Timing Mismatch Comm REMOTE_NODE_TRANSMISSION_ERROR MINOR ImaGroup
IMA Link Out of Delay Synchronization Comm LOCAL_NODE_TRANSMISSION_ERROR MAJOR ImaLink
IMA Link Reception Misconnected Comm LOCAL_NODE_TRANSMISSION_ERROR MAJOR ImaLink
IMA Link Reception Unusable at Far End Comm REMOTE_NODE_TRANSMISSION_ERROR WARNING ImaLink
IMA Link Transmission Misconnected Comm LOCAL_NODE_TRANSMISSION_ERROR MAJOR ImaLink
IMA Link Transmit Unusable at Far End Comm REMOTE_NODE_TRANSMISSION_ERROR WARNING ImaLink
Loss of Cell Delineation on IMA Link Comm LOCAL_NODE_TRANSMISSION_ERROR MAJOR ImaLink
Loss of IMA Frame Comm LOCAL_NODE_TRANSMISSION_ERROR MAJOR ImaLink
Remote Defect Indication on IMA Link Comm REMOTE_NODE_TRANSMISSION_ERROR WARNING ImaLink

Alarm and Event List - Alarms 35 / 46


APPENDIX: Alarm and Event List - Alarms

Loss of Link Redundancy Group 0 QoS LOST_REDUNDANCY MINOR InternalLinkGroup


Loss of Link Redundancy Group 1 QoS LOST_REDUNDANCY MINOR InternalLinkGroup
Loss of Link Redundancy Group 2 QoS LOST_REDUNDANCY MINOR InternalLinkGroup
Loss of Link Redundancy Group 3 QoS LOST_REDUNDANCY MINOR InternalLinkGroup
Switch Internal Link Group 0 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR InternalLinkGroup
Switch Internal Link Group 1 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR InternalLinkGroup
Switch Internal Link Group 2 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR InternalLinkGroup
Switch Internal Link Group 3 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR InternalLinkGroup
InterSubTimingCable_ClockDistributionMalfunction Eq CLOCK_SYNCHRONISATION_PROBLEM MAJOR InterSubTimingCable
IntraCabTimingCable_ClockDistributionMalfunction Eq CLOCK_SYNCHRONISATION_PROBLEM MAJOR IntraCabTimingCable
Contact to Default Router 0 Lost Comm UNAVAILABLE MAJOR IpInterface
Contact to Default Router 1 Lost Comm UNAVAILABLE MAJOR IpInterface
Contact to Default Router 2 Lost Comm UNAVAILABLE MAJOR IpInterface
NTP Server Reachability Fault Comm UNAVAILABLE Major IpSyncRef
Iub_DualStackIubFeatureNotActivated ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Iub
Looped Link Comm TRANSMISSION_ERROR WARNING J1PhysPathTerm
PDH Alarm Indication Signal Comm ALARM_INDICATION_SIGNAL WARNING J1PhysPathTerm
PDH Degraded Signal Comm DEGRADED_SIGNAL_M3100 MINOR J1PhysPathTerm
PDH Loss of Frame Comm LOSS_OF_FRAME MAJOR J1PhysPathTerm
PDH Loss of Signal Comm LOSS_OF_SIGNAL MAJOR J1PhysPathTerm
PDH Remote Defect Indication Comm FAR_END_RECEIVER_FAILURE WARNING J1PhysPathTerm
Emergency Unlock of Software Licensing QoS ALARM_INDICATION_SIGNAL MINOR Licensing
License Key File Fault QoS CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Licensing
LoPowTxCable_Disconnected Eq EQUIPMENT_MALFUNCTION MAJOR LoPowTxCable
M3UA Local AS Down Comm UNAVAILABLE MAJOR M3uaLocalAs
M3UA Remote AS Down Comm UNAVAILABLE MAJOR M3uaRemoteAs
M3UA Remote SP Down Comm UNAVAILABLE MAJOR M3uaRemoteSp
M3UA Association Down Comm UNAVAILABLE MAJOR M3uAssociation
Large Number of Counters QoS PERFORMANCE_DEGRADED WARNING ManagedElement
Maximum Number of Counters Exceeded QoS PERFORMANCE_DEGRADED MINOR ManagedElement
Disk Volume C Full Eq DISK_PROBLEM MAJOR ManagedElement
McpaDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR McpaDeviceGroup
McpaDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR McpaDeviceGroup
McpaDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR McpaDeviceGroup
McpaDeviceGroup_TakenOutOfServiceToProtectCu Env TEMPERATURE_UNACCEPTABLE MAJOR McpaDeviceGroup
McpaDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR McpaDeviceGroup
McpaDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR McpaDeviceGroup
McpaDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR McpaDeviceGroup
McpaDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR McpaDeviceGroup
McpaDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR McpaDeviceGroup
Failure of Protocol Comm COMMUNICATION_PROTOCOL_ERROR MAJOR Mspg
Failure of Protocol Comm COMMUNICATION_PROTOCOL_ERROR MAJOR MspgExtended
MTP3b Link Out of Service Comm UNAVAILABLE WARNING Mtp3bSlAnsi
MTP3b Link Out of Service Comm UNAVAILABLE WARNING Mtp3bSlChina
MTP3b Link Out of Service Comm UNAVAILABLE WARNING Mtp3bSlItu
MTP3b Link Out of Service Comm UNAVAILABLE WARNING Mtp3bSlTtc
MTP3b Route Set Unavailable Comm ROUTING_FAILURE MAJOR Mtp3bSrs
NbapCommon_Layer3SetupFailure Comm COMMUNICATION_SUBSYSTEM_FAILURE CRITICAL NbapCommon
NodeBFunction_16QamLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_64QamLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_DlHwUsageExceedsDlLicenseLevel ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR NodeBFunction
NodeBFunction_DualStackIubLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_EnhancedLayer2LicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_Eul2msTtiLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_EulGrakeLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_HsdpaDynamicCodeAllocationLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_HsdpaFlexibleSchedulerLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_HsdpaIncrementalRedundancyLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_MbmsIubEfficiencyLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_StandardizedRetLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_StandardizedTmaLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
NodeBFunction_UlHwUsageExceedsUlLicenseLevel ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR NodeBFunction
NodeBFunctionDlPowerControlEulLicenseNotValid QoS UNAVAILABLE MAJOR NodeBFunction
ObifDeviceGroup_ClockDistributionMalfunction Eq CLOCK_SYNCHRONISATION_PROBLEM MAJOR ObifDeviceGroup
ObifDeviceGroup_DpProgramNotConfigured ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR ObifDeviceGroup
ObifDeviceGroup_GammaLinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR ObifDeviceGroup
ObifDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR ObifDeviceGroup
ObifDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR ObifDeviceGroup
ObifDeviceGroup_LossOfSynch Eq LOSS_OF_SYNCHRONISATION MAJOR ObifDeviceGroup
ObifDeviceGroup_MpDbCommunicationFailure Eq EQUIPMENT_MALFUNCTION MAJOR ObifDeviceGroup
ObifDeviceGroup_PoorClockSignal Eq TIMING_PROBLEM_M3100 MAJOR ObifDeviceGroup
ObifDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR ObifDeviceGroup
ObifDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR ObifDeviceGroup
ObifDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR ObifDeviceGroup
ObifDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR ObifDeviceGroup
ObifDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR ObifDeviceGroup
ObifDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR ObifDeviceGroup
OpticalInterfaceLink_OpticalInterfaceLinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR OpticalInterfaceLink
OpticalInterfaceLink_TooLongOpticalInterfaceLink Eq EQUIPMENT_MALFUNCTION MAJOR OpticalInterfaceLink
OptoCommCable_OptoCommunicationFailure Eq EQUIPMENT_MALFUNCTION MAJOR OptoCommCable
Invalid Optical Module Eq REPLACEABLE_UNIT_PROBLEM MAJOR Os155SpiTtp
Loss of Frame Comm LOSS_OF_FRAME MAJOR Os155SpiTtp
Loss of Signal Comm LOSS_OF_SIGNAL MAJOR Os155SpiTtp
MS Alarm Indication Signal Comm ALARM_INDICATION_SIGNAL WARNING Os155SpiTtp
MS Degraded Signal Comm DEGRADED_SIGNAL_M3100 MINOR Os155SpiTtp
MS Excessive Bit Error Rate Comm EXCESSIVE_BIT_ERROR_RATE MAJOR Os155SpiTtp
MS Remote Defect Indication Comm FAR_END_RECEIVER_FAILURE WARNING Os155SpiTtp
OSPF - Working Mode Disabled Comm ROUTING_FAILURE MAJOR Ospf
OutDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR OutDeviceSet
OutDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR OutDeviceSet
PauDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR PauDeviceGroup
PauDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR PauDeviceGroup
PauDeviceGroup_HwSwMismatch ProcErr VERSION_MISMATCH MAJOR PauDeviceGroup
PcuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR PcuDeviceGroup
PcuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR PcuDeviceGroup
PcuDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR PcuDeviceGroup

Alarm and Event List - Alarms 36 / 46


APPENDIX: Alarm and Event List - Alarms

PcuDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR PcuDeviceGroup


PcuDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR PcuDeviceGroup
PcuDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR PcuDeviceGroup
PcuDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR PcuDeviceGroup
PcuDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR PcuDeviceGroup
PdDevice_CurrentTooHigh Eq POWER_PROBLEM_M3100 MAJOR PdDevice
PdDevice_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR PdDevice
PdDevice_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR PdDevice
PdDevice_InputVoltageTooHigh Eq POWER_PROBLEM_M3100 MAJOR PdDevice
PdDevice_InputVoltageTooLow Eq POWER_PROBLEM_M3100 MAJOR PdDevice
PdDevice_SoftStarterBreakerFailure Eq EQUIPMENT_MALFUNCTION MAJOR PdDevice
PdDevice_SystemVoltageTooHigh Eq POWER_PROBLEM_M3100 MAJOR PdDevice
PdDevice_SystemVoltageTooLow Eq POWER_PROBLEM_M3100 MAJOR PdDevice
PdDevice_TransistorFailure Eq EQUIPMENT_MALFUNCTION MAJOR PdDevice
Board Overheated QoS HIGH_TEMPERATURE MAJOR PlugInUnit
Hardware Failure Imminent Eq PERFORMANCE_DEGRADED MAJOR PlugInUnit
Disk Volume D Full Eq DISK_PROBLEM MAJOR PlugInUnit
Plug-In Unit General Problem Eq REPLACEABLE_UNIT_PROBLEM MINOR PlugInUnit
Plug-In Unit HW Failure Eq REPLACEABLE_UNIT_PROBLEM MINOR PlugInUnit
Plug-In Unit Synch Hardware Fault Eq REPLACEABLE_UNIT_PROBLEM MAJOR PlugInUnit
Switch Core Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR PlugInUnit
Switch Port Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR PlugInUnit
PowerDistrSystem_MeasurementsNotReceived Eq EQUIPMENT_MALFUNCTION MAJOR PowerDistrSystem
PowerDistrSystem_RejectSignalFromHardware ProcErr MESSAGE_NOT_EXPECTED MAJOR PowerDistrSystem
PowerDistrSystem_SignalNotReceivedWithinTime ProcErr TIMEOUT_EXPIRED MAJOR PowerDistrSystem
PowerSupplySystem_BatteryOverTemperature Eq BATTERY_CHARGING_FAULT MAJOR PowerSupplySystem
PowerSupplySystem_LossOfMains Eq COMMERICAL_POWER_FAILURE MAJOR PowerSupplySystem
PowerSupplySystem_LowBatteryCapacity Eq BATTERY_CHARGING_FAULT MINOR PowerSupplySystem
PowerSupplySystem_MainsOvervoltage Eq POWER_PROBLEM_M3100 MINOR PowerSupplySystem
PowerSupplySystem_MeasurementsNotReceived Eq EQUIPMENT_MALFUNCTION MAJOR PowerSupplySystem
PowerSupplySystem_RadioResourcesShutDown Env BATTERY_DISCHARGING MAJOR PowerSupplySystem
PowerSupplySystem_RejectSignalFromHardware ProcErr MESSAGE_NOT_EXPECTED MAJOR PowerSupplySystem
PowerSupplySystem_RunningOnBatterySupply Env BATTERY_DISCHARGING MINOR PowerSupplySystem
PowerSupplySystem_SignalNotReceivedWithinTime ProcErr TIMEOUT_EXPIRED MAJOR PowerSupplySystem
PowerSupplySystem_SystemOvervoltage Eq POWER_PROBLEM_M3100 MAJOR PowerSupplySystem
PowerSupplySystem_SystemUndervoltage Eq POWER_PROBLEM_M3100 MAJOR PowerSupplySystem
PredefRbsScannerGpeh_FailedToWriteFile ProcErr FILE_ERROR MINOR PredefRbsScannerGpeh
PsDevice_LossOfMains Eq COMMERICAL_POWER_FAILURE MAJOR PsDevice
PsDeviceSet_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR PsDeviceSet
PsDeviceSet_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR PsDeviceSet
PsDeviceSet_LossOfMains Eq COMMERICAL_POWER_FAILURE MAJOR PsDeviceSet
PsDeviceSet_NumberOfHwEntitiesMismatch ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR PsDeviceSet
Psu_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR Psu
Psu_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR Psu
Psu_LossOfMains Eq COMMERICAL_POWER_FAILURE MAJOR Psu
Psu_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR Psu
Psu_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR Psu
Psu_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR Psu
Psu_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR Psu
Psu_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR Psu
PsuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR PsuDeviceGroup
PsuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR PsuDeviceGroup
PsuDeviceGroup_HwSwMismatch ProcErr VERSION_MISMATCH MAJOR PsuDeviceGroup
PsuDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR PsuDeviceGroup
PsuDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR PsuDeviceGroup
PsuDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR PsuDeviceGroup
PsuDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR PsuDeviceGroup
PsuDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR PsuDeviceGroup
RaxDeviceGroup_AtmConfigurationMismatch ProcErr VERSION_MISMATCH MAJOR RaxDeviceGroup
RaxDeviceGroup_BackplaneBusCollision ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RaxDeviceGroup
RaxDeviceGroup_DpProgramNotConfigured ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR RaxDeviceGroup
RaxDeviceGroup_GammaLinkFailure ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RaxDeviceGroup
RaxDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR RaxDeviceGroup
RaxDeviceGroup_GeneralSwError Eq EQUIPMENT_MALFUNCTION MAJOR RaxDeviceGroup
RaxDeviceGroup_HwNotSupported ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RaxDeviceGroup
RaxDeviceGroup_IncompatibleGammaBusProtocol ProcErr SOFTWARE_ERROR MAJOR RaxDeviceGroup
RaxDeviceGroup_LossOfSynch Eq LOSS_OF_SYNCHRONISATION MAJOR RaxDeviceGroup
RaxDeviceGroup_MpDbCommunicationFailure Eq EQUIPMENT_MALFUNCTION MAJOR RaxDeviceGroup
RaxDeviceGroup_PoorClockSignal Eq TIMING_PROBLEM_M3100 MAJOR RaxDeviceGroup
RaxDeviceGroup_RaxTxInterfaceCommunicationError Eq EQUIPMENT_MALFUNCTION MAJOR RaxDeviceGroup
RaxDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR RaxDeviceGroup
RaxDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR RaxDeviceGroup
RaxDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR RaxDeviceGroup
RaxDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR RaxDeviceGroup
RaxDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR RaxDeviceGroup
RaxDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR RaxDeviceGroup
RbsLocalCell_CellRangeExceedsLicensedLimit QoS UNAVAILABLE MAJOR RbsLocalCell
RbsLocalCell_MaxNumEulUsersExceedsLicensedLimit QoS UNAVAILABLE MAJOR RbsLocalCell
RbsLocalCell_MaxNumHsdpaUsersExceedsLicensedLimit QoS UNAVAILABLE MAJOR RbsLocalCell
RbsLocalCell_MaxNumHsPdschCodesExceedsLicensedLimit QoS UNAVAILABLE MAJOR RbsLocalCell
RbsLocalCell_OcnsTransmissionFailure ProcErr TRANSMISSION_ERROR WARNING RbsLocalCell
RbsSynchronization_RejectSignalFromHardware ProcErr MESSAGE_NOT_EXPECTED MAJOR RbsSynchronization
RbsSynchronization_SignalNotReceivedWithinTime ProcErr TIMEOUT_EXPIRED MAJOR RbsSynchronization
RbsSynchronization_TimingUnitsNotSynchronized Eq REPLACEABLE_UNIT_PROBLEM WARNING RbsSynchronization
RetDevice_ElectricalAntennaTiltOutOfRange ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR RetDevice
RetDevice_RetFailure Eq EQUIPMENT_MALFUNCTION MAJOR RetDevice
RetDevice_RetProfileParameterError Eq EQUIPMENT_MALFUNCTION MINOR RetDevice
RetDevice_SignalNotReceivedWithinTime ProcErr TIMEOUT_EXPIRED MAJOR RetDevice
RetDeviceSet_RetFailure Eq EQUIPMENT_MALFUNCTION MAJOR RetDeviceSet
RetuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR RetuDeviceGroup
RetuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR RetuDeviceGroup
RetuDeviceGroup_RetPowerConsumptionTooHigh Eq EQUIPMENT_MALFUNCTION MAJOR RetuDeviceGroup
RfCable_Disconnected Eq EQUIPMENT_MALFUNCTION MAJOR RfCable
RfifDeviceGroup_ClockDistributionMalfunction Eq CLOCK_SYNCHRONISATION_PROBLEM MAJOR RfifDeviceGroup
RfifDeviceGroup_DpProgramNotConfigured ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RfifDeviceGroup
RfifDeviceGroup_GammaLinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR RfifDeviceGroup

Alarm and Event List - Alarms 37 / 46


APPENDIX: Alarm and Event List - Alarms

RfifDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR RfifDeviceGroup


RfifDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR RfifDeviceGroup
RfifDeviceGroup_IncompatiblePowerClippingAlgorithm ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR CRITICAL RfifDeviceGroup
RfifDeviceGroup_IncorrectCableForDeliveredClock Eq EQUIPMENT_MALFUNCTION MAJOR RfifDeviceGroup
RfifDeviceGroup_IncorrectCableForReceivedClock Eq EQUIPMENT_MALFUNCTION MAJOR RfifDeviceGroup
RfifDeviceGroup_LossOfSynch Eq LOSS_OF_SYNCHRONISATION MAJOR RfifDeviceGroup
RfifDeviceGroup_MpDbCommunicationFailure Eq EQUIPMENT_MALFUNCTION MAJOR RfifDeviceGroup
RfifDeviceGroup_PoorClockSignal Eq TIMING_PROBLEM_M3100 MAJOR RfifDeviceGroup
RfifDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR RfifDeviceGroup
RfifDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR RfifDeviceGroup
RfifDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR RfifDeviceGroup
RfifDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR RfifDeviceGroup
RfifDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR RfifDeviceGroup
RfifDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR RfifDeviceGroup
RruDeviceGroup_ConfigurationMismatchWithAntennaEquipment ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RruDeviceGroup
RruDeviceGroup_FanFailure Eq EQUIPMENT_MALFUNCTION MAJOR RruDeviceGroup
RruDeviceGroup_GammaLinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR RruDeviceGroup
RruDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR RruDeviceGroup
RruDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR RruDeviceGroup
RruDeviceGroup_HwNotSupported ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RruDeviceGroup
RruDeviceGroup_NumberOfHwEntitiesMismatch ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RruDeviceGroup
RruDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR RruDeviceGroup
RruDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR RruDeviceGroup
RruDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR RruDeviceGroup
RruDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR RruDeviceGroup
RruDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR RruDeviceGroup
RruDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR RruDeviceGroup
RuDeviceGroup_ExternalUnitFailure Eq EQUIPMENT_MALFUNCTION MAJOR RuDeviceGroup
RuDeviceGroup_GammaDownlinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR RuDeviceGroup
RuDeviceGroup_GammaUplinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR RuDeviceGroup
RuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR RuDeviceGroup
RuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR RuDeviceGroup
RuDeviceGroup_HwNotSupported ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RuDeviceGroup
RuDeviceGroup_LossOfSynch Eq LOSS_OF_SYNCHRONISATION MAJOR RuDeviceGroup
RuDeviceGroup_NumberOfHwEntitiesMismatch ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RuDeviceGroup
RuDeviceGroup_PoorClockSignal Eq TIMING_PROBLEM_M3100 MAJOR RuDeviceGroup
RuDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR RuDeviceGroup
RuDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR RuDeviceGroup
RuDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR RuDeviceGroup
RuDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR RuDeviceGroup
RuDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR RuDeviceGroup
RuDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR RuDeviceGroup
RuifDeviceGroup_ClockDistributionMalfunction Eq CLOCK_SYNCHRONISATION_PROBLEM MAJOR RuifDeviceGroup
RuifDeviceGroup_DpProgramNotConfigured ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR RuifDeviceGroup
RuifDeviceGroup_GammaDownlinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR RuifDeviceGroup
RuifDeviceGroup_GammaUplinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR RuifDeviceGroup
RuifDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR RuifDeviceGroup
RuifDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR RuifDeviceGroup
RuifDeviceGroup_LossOfSynch Eq LOSS_OF_SYNCHRONISATION MAJOR RuifDeviceGroup
RuifDeviceGroup_MpDbCommunicationFailure Eq EQUIPMENT_MALFUNCTION MAJOR RuifDeviceGroup
RuifDeviceGroup_PoorClockSignal Eq TIMING_PROBLEM_M3100 MAJOR RuifDeviceGroup
RuifDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR RuifDeviceGroup
RuifDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR RuifDeviceGroup
RuifDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR RuifDeviceGroup
RuifDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR RuifDeviceGroup
RuifDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR RuifDeviceGroup
RuifDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR RuifDeviceGroup
SaiuDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR SaiuDeviceGroup
SaiuDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR SaiuDeviceGroup
SaiuDeviceGroup_HwSwMismatch ProcErr VERSION_MISMATCH MAJOR SaiuDeviceGroup
SCCP Remote Subsystem Unavailable Comm UNAVAILABLE WARNING SccpApRemote
Sector_FrequencyBandNotSupported ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Sector
Sector_MissingRetProfile ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR Sector
Sector_RejectSignalFromHardware ProcErr MESSAGE_NOT_EXPECTED MAJOR Sector
Sector_SignalNotReceivedWithinTime ProcErr TIMEOUT_EXPIRED MAJOR Sector
SectorAntenna_FeederCurrentTooHigh Eq EQUIPMENT_MALFUNCTION MAJOR SectorAntenna
SectorAntenna_FeederCurrentTooLow Eq EQUIPMENT_MALFUNCTION MAJOR SectorAntenna
Credentials Enrollment Fault QoS CONFIGURATION_OR_CUSTOMIZING_ERROR WARNING Security
Credentials Validity Fault QoS CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Security
Local AA DB Installation Fault QoS CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR Security
Password File Fault QoS CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR Security
Security Level Fault QoS CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR Security
Trusted Certificate Installation Fault QoS CONFIGURATION_OR_CUSTOMIZING_ERROR MINOR Security
Auto-Configuration of Board Not Possible Eq UNAVAILABLE WARNING Slot
SPM General Problem Eq EQUIPMENT_MALFUNCTION MINOR Spm
SPM High Temperature Env HIGH_TEMPERATURE MINOR Spm
SPM HW Failure Eq PROCESSOR_PROBLEM_M3100 MINOR Spm
StrxDeviceGroup_DpProgramNotConfigured ProcErr CONFIGURATION_OR_CUSTOMIZING_ERROR MAJOR StrxDeviceGroup
StrxDeviceGroup_GammaLinkFailure Eq EQUIPMENT_MALFUNCTION MAJOR StrxDeviceGroup
StrxDeviceGroup_GeneralHwError Eq EQUIPMENT_MALFUNCTION MAJOR StrxDeviceGroup
StrxDeviceGroup_GeneralSwError ProcErr SOFTWARE_ERROR MAJOR StrxDeviceGroup
StrxDeviceGroup_LossOfSynch Eq LOSS_OF_SYNCHRONISATION MAJOR StrxDeviceGroup
StrxDeviceGroup_MpDbCommunicationFailure Eq EQUIPMENT_MALFUNCTION MAJOR StrxDeviceGroup
StrxDeviceGroup_PoorClockSignal Eq TIMING_PROBLEM_M3100 MAJOR StrxDeviceGroup
StrxDeviceGroup_SoftwareDownloadFailure ProcErr SOFTWARE_DOWNLOAD_FAILURE MAJOR StrxDeviceGroup
StrxDeviceGroup_TemperatureAbnormallyHigh Env HIGH_TEMPERATURE MINOR StrxDeviceGroup
StrxDeviceGroup_TemperatureAbnormallyLow Env LOW_TEMPERATURE MINOR StrxDeviceGroup
StrxDeviceGroup_TemperatureExceptionallyHigh Env TEMPERATURE_UNACCEPTABLE MAJOR StrxDeviceGroup
StrxDeviceGroup_TemperatureExceptionallyLow Env TEMPERATURE_UNACCEPTABLE MAJOR StrxDeviceGroup
StrxDeviceGroup_TemperatureSupervisionFailure Eq EQUIPMENT_MALFUNCTION MINOR StrxDeviceGroup
Alarm Indication Signal - P Comm ALARM_INDICATION_SIGNAL WARNING Sts1SpeTtp
Connectivity RDI - P Comm FAR_END_RECEIVER_FAILURE WARNING Sts1SpeTtp
Loss of Pointer - P Comm LOSS_OF_POINTER MAJOR Sts1SpeTtp
Payload Mismatch - P Comm PAYLOAD_TYPE_MISMATCH MAJOR Sts1SpeTtp
Payload RDI - P Comm FAR_END_RECEIVER_FAILURE WARNING Sts1SpeTtp
Server RDI - P Comm FAR_END_RECEIVER_FAILURE WARNING Sts1SpeTtp

Alarm and Event List - Alarms 38 / 46


APPENDIX: Alarm and Event List - Alarms

Trace Identifier Mismatch - P Comm PATH_TRACE_MISMATCH MAJOR Sts1SpeTtp


Unequipped Defect - P Comm SIGNAL_LABEL_MISMATCH MAJOR Sts1SpeTtp
Trace Identifier Mismatch - P Comm PATH_TRACE_MISMATCH MAJOR Sts3CspcTtp
Unequipped Defect - P Comm SIGNAL_LABEL_MISMATCH MAJOR Sts3CspcTtp
Alarm Indication Signal - P Comm ALARM_INDICATION_SIGNAL WARNING Sts3CspeTtp
Connectivity RDI - P Comm FAR_END_RECEIVER_FAILURE WARNING Sts3CspeTtp
Payload Mismatch - P Comm PAYLOAD_TYPE_MISMATCH MAJOR Sts3CspeTtp
Payload RDI - P Comm FAR_END_RECEIVER_FAILURE WARNING Sts3CspeTtp
Server RDI - P Comm FAR_END_RECEIVER_FAILURE WARNING Sts3CspeTtp
Loss of Pointer - P Comm LOSS_OF_POINTER MAJOR Sts3CspeTtp.
Power Failure Left Slot Eq POWER_PROBLEM_M3100 MAJOR Subrack
Power Failure Right Slot Eq POWER_PROBLEM_M3100 MAJOR Subrack
SCB System Clock Path HW Fault Eq REPLACEABLE_UNIT_PROBLEM MAJOR SwitchCoreUnit
Switch Internal Link Port 0 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR SwitchCoreUnit
Switch Internal Link Port 1 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR SwitchCoreUnit
Switch Internal Link Port 2 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR SwitchCoreUnit
Switch Internal Link Port 3 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR SwitchCoreUnit
Switch Internal Link Port 0 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR SwitchExtensionUnit
Switch Internal Link Port 1 Fault Eq REPLACEABLE_UNIT_PROBLEM MINOR SwitchExtensionUnit

Alarm and Event List - Alarms 39 / 46


APPENDIX: Alarm and Event List - Events

Alarm and Event List


15/006 51-HRB 105 102/1 Uen

specificEvent Description Managed Object


AiuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is AiuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
AiuDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is AiuDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
AiuDeviceGroup_SuccessfulRecoveryActionPerformedBoardRA restart of the whole Device Board or Auxiliary Unit has been performed. AiuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
AscDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is AscDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
AscDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is AscDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
AscDeviceGroup_SuccessfulRecoveryActionPerformedBoard When a hardware test is manually initiated, an event notification is sent when the test is AscDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
AuxPlugInUnit_NewAuxiliaryUnitDetectedMatchesTheDefinedAn Auxiliary Plug-in Unit is replaced by an older, or newer, version and is unlocked. AuxPlugInUnit

The event is issued if reconfigurations were required and have been performed.
AuxPlugInUnit_NewAuxiliaryUnitDetectedNoPredefinedConfigAn Auxiliary Plug-in Unit is replaced by an older or newer version and an attempt to unlock AuxPlugInUnit
the unit is made.

The event is issued if no predefined configuration exists.


AuxPlugInUnit_SuccessfulRecoveryActionPerformedReestab AuxPlugInUnit
A switching of communication path to Auxiliary Unit or Non-processing Unit has been
performed.

The Auxiliary Unit or Non-processing Unit can be connected to two Device Boards. If the link
between the Main Processor and Auxiliary Unit or Non-processing Unit goes down, the Main
Processor can set up a communication path through the other Device Board.
AuxPlugInUnit_SuccessfulRecoveryActionPerformedSwitched AuxPlugInUnit
A switching of communication path to Auxiliary Unit or Non-processing Unit has been
performed.

The Auxiliary Unit or Non-processing Unit can be connected to two Device Boards. If the link
between the Main Processor and Auxiliary Unit or Non-processing Unit goes down, the Main
Processor can set up a communication path through the other Device Board.
BbifBoard_SuccessfulRecoveryActionPerformedReestablishe BbifBoard
A switching of communication path to Auxiliary Unit or Non-processing Unit has been
performed.

The Auxiliary Unit or Non-processing Unit can be connected to two Device Boards. If the link
between the Main Processor and Auxiliary Unit or Non-processing Unit goes down, the Main
Processor can set up a communication path through the other Device Board.
BfuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is BfuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
BfuDeviceGroup_SuccessfulRecoveryActionPerformedBoard A restart of the whole Device Board or Auxiliary Unit has been performed. BfuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
CluDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is CluDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
CluDeviceGroup_SuccessfulRecoveryActionPerformedBoard A restart of the whole Device Board or Auxiliary Unit has been performed. CluDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
CuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is CuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds

Alarm and Event List - Events 40 / 46


APPENDIX: Alarm and Event List - Events

specificEvent Description Managed Object


CuDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is CuDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
CuDeviceGroup_SuccessfulRecoveryActionPerformedBoardRA restart of the whole Device Board or Auxiliary Unit has been performed. CuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
DeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is DeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
DeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is DeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor.
DeviceGroup_SuccessfulRecoveryActionPerformedBoardResA restart of the whole Device Board has been performed. DeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
E1PhysPathTerm_NoCRC4Mfa In CRC-4 mode, AUTOMATIC, the frame alignment algorithm has entered the state: Assume E1PhysPathTerm
CRC-4-to-non-CRC-4 interworking.
PHY_E1Ppt_MI_AUTOLOCK_IND A port is locked. E1PhysPathTerm
E1Ttp_NOCRC4MFA In CRC-4 mode, AUTOMATIC, the frame alignment algorithm has entered the state: Assume E1Ttp
CRC-4-to-non-CRC-4 interworking.
PHY_E3Ppt_MI_AUTOLOCK_IND A port is locked. E3PhysPathTerm
A Non-Local MAU Has Been Chosen as the Active Client Split Ethernet Server is not executing on the same MP as the Split Ethernet Client. EthernetLink
Fan_New Fan detected, matches the defined configuration The new hardware can be used. No reconfiguration was needed, or the node reconfigured Fan
itself automatically.
Fan_New Fan detected, no predefined configuration exist This fan cannot be used. There is no software allocation for the fan. Fan
FanDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is FanDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
FanDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is FanDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
FanDeviceGroup_SuccessfulRecoveryActionPerformedBoardA restart of the whole Device Board or Auxiliary Unit has been performed. FanDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
FcuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is FcuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
FcuDeviceGroup_SuccessfulRecoveryActionPerformedBoard A restart of the whole Device Board or Auxiliary Unit has been performed. FcuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
FuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is FuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
FuDeviceGroup_SuccessfulRecoveryActionPerformedBoardRA restart of the whole Device Board or Auxiliary Unit has been performed. FuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
Link switched Traffic has moved from one link to the other link. GigaBitEthernet
One of two links outage One Ethernet link has failed. (One link is still in operation.) GigaBitEthernet
One of two links outage ceased One failed Ethernet link has recovered. (Two links are now in operation.) GigaBitEthernet
InterSubTimingCable_SuccessfulRecoveryActionPerformedS A switching of BB Clock source has been performed. InterSubTimingCable

All RAX and TX boards always get their BB clock from either the BBIF1 or BBIF2. The clock
source can be switched between these two boards.
IntraCabTimingCable_SuccessfulRecoveryActionPerformedS A switching of BB Clock source has been performed. IntraCabTimingCable

All RAX and TX boards always get their BB clock from either the BBIF1 or BBIF2. The clock
source can be switched between these two boards.
Ip over ATM Link Supervision Failed The operational state of the MO has become DISABLED. IpAtmLink
Ip over ATM Link Supervision Recovered The operational state of the MO has become ENABLED. IpAtmLink
Default router switch The default router for traffic has changed. IpInterface
PHY_J1Ppt_MI_AUTOLOCK_IND A port is locked. J1PhysPathTerm
Licensing_CapacityChange A license-controlled capacity has changed value. Licensing
Licensing_FaultyFormatVersion The format version is faulty in the license key file. Licensing
Licensing_FaultyLicenseKey A license key is faulty in the license key file. Licensing
Licensing_FaultySeqNum The sequence number is faulty in the license key file. Licensing
Licensing_FaultySignature The signature is faulty in the license key file. Licensing
Licensing_FeatureChange A license-controlled feature has changed state. Licensing
Licensing_FingerPrintMismatch The fingerprint on the node does not match the fingerprint in the license key file. Licensing
Licensing_MultipleLicenses Multiple license keys are found in the license key file. Licensing

Alarm and Event List - Events 41 / 46


APPENDIX: Alarm and Event List - Events

specificEvent Description Managed Object


Push Log Failed Information has been lost for a log, because it was deleted before it could be transferred to Log
the FTP server. The log is specified in additionalInfo.
OAM_Recovery_Progress The percentage of the completion of the OAM Recovery Process. ManagedElement
McpaDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is McpaDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
McpaDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is McpaDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
McpaDeviceGroup_SuccessfulRecoveryActionPerformedBoa A restart of the whole Device Board or Auxiliary Unit has been performed. McpaDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
Mspg_ProtectionSwitch A switch to the standby board or port has been made. This board or port is now handling Mspg
traffic.
Mspg_ProtectionSwitchFailure An attempt to switch to the standby board or port has failed. Mspg
PHY_MSPGMI_K2MISMATCH_IND The K2 MISMATCH protocol state is entered. Mspg
NodeBFunction_DlHwUsageLimitedToLicensedLevel UL and DL BB capacity is not immediately limited by levels specified in BB capacity LKs. NodeBFunction
When the grace period is over, the capacity is restricted to the licensed level and the event is
issued.
NodeBFunction_MainProcessorRestarted The main processor is restarted for one of the following reasons: NodeBFunction
Power on
Reset button
SW initiated
Watch dog
Undefined
NodeBFunction_MpTrafficApplicationRestarted NodeBFunction
The Main Processor Traffic Application is restarted.

The event is issued whenever the restart of an active Main Processor Traffic Application is
performed by the application itself, or triggered by a restart of the Main Processor in the RBS.
NodeBFunction_NodeRestarted The node is restarted for one of the NodeBFunction
following reasons:
Power on
Reset button
SW initiated
Watch dog
Undefined
NodeBFunction_OaMApplicationRestarted This event is issued any time the restart of an active O&M Application is performed by the NodeBFunction
application itself, that is not triggered by a processor restart.

The event is also issued when a passive O&M Application is activated.


NodeBFunction_SuccessfulProgramSwitchOverOfMpTrafficA Probable cause is one of the following: NodeBFunction
Manually Ordered
Main Processor Failure/Restart
NodeBFunction_ToaweDchMismatch Radio Link Reconfiguration or Radio Link Setup is rejected, because the parameter NodeBFunction
ToAWE_DCH > (200 ms - toaeDch)
NodeBFunction_ToaweDchOutOfRange Radio Link Reconfiguration or Radio Link Setup is rejected, because the parameter NodeBFunction
ToAWE_DCH > 200 ms
NodeBFunction_ToaweFachMismatch Common Channel Reconfiguration or Common Transport Channel Setup is rejected, NodeBFunction
because the parameter ToAWE_FACH > (200 ms - toaeCch)
NodeBFunction_ToaweFachOutOfRange Common Channel Reconfiguration or Common Transport Channel Setup is rejected, NodeBFunction
because the parameter ToAWE_FACH > 200 ms
NodeBFunction_ToawePchMismatch Common Channel Reconfiguration or Common Transport Channel Setup is rejected, NodeBFunction
because the parameter ToAWE_PCH > (200 ms - toaeCch)
NodeBFunction_ToawePchOutOfRange Common Channel Reconfiguration or Common Transport Channel Setup is rejected, NodeBFunction
because the parameter ToAWE_PCH > 200 ms
NodeBFunction_ToawsDchMismatch Radio Link Reconfiguration or Radio Link Setup is rejected, because the parameter NodeBFunction
ToAWS_DCH > toaeDch
NodeBFunction_ToawsFachMismatch Common Channel Reconfiguration or Common Transport Channel Setup is rejected, NodeBFunction
because the parameter ToAWS_FACH > toaeCch
NodeBFunction_ToawsPchMismatch Common Channel Reconfiguration or Common Transport Channel Setup is rejected because NodeBFunction
the parameter because the parameter ToAWS_PCH > toaeCch
NodeBFunction_UlHwUsageLimitedToLicensedLevel UL and DL BB capacity is not immediately limited by levels specified in BB capacity NodeBFunction
LKs.When the grace period is over, the capacity is restricted to the licensed level and the
event is issued.
ObifDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is ObifDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
ObifDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is ObifDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
ObifDeviceGroup_SuccessfulRecoveryActionPerformedBoardA restart of the whole Device Board or Auxiliary Unit has been performed. ObifDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
ObifDeviceGroup_SuccessfulRecoveryActionPerformedReestThis event is sent when there is a short period of gamma link failure. ObifDeviceGroup

Alarm and Event List - Events 42 / 46


APPENDIX: Alarm and Event List - Events

specificEvent Description Managed Object


OpticalInterfaceLink_OilDelayChanged This event is sent when there is a significant change in OIL cable length during operation, OpticalInterfaceLink
probably due to a big temperature change or mechanical stress affecting several hundred
meters of the cable.
PHY_Os155Spi_MI_AUTOLOCK_IND A port is locked. Os155SpiTtp
PauDeviceGroup_SuccessfulRecoveryActionPerformedBoardA restart of the whole Device Board or Auxiliary Unit has been performed. PauDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
Pccpch_DownLinkChannelResourceRedundancySwitchOver New hardware has been allocated. The channels BCH and PCCPCH have been set up on thePccpch
new hardware, and have started sending system information.

An FM event is sent to indicate a successful switch over to the other TXB.


PcuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is PcuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
PcuDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is PcuDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
PcuDeviceGroup_SuccessfulRecoveryActionPerformedBoardA restart of the whole Device Board or Auxiliary Unit has been performed. PcuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
PowerSupplySystem_BatteryTestResult A battery test has been performed. PowerSupplySystem

Additional information displayed:


Start reason: Initial/Manually/Automatic/AC failure
Battery capacity, given in Ah
Battery backup time, given in minutes
PsuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is PsuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
PsuDeviceGroup_SuccessfulRecoveryActionPerformedBoardA restart of the whole Device Board or Auxiliary Unit has been performed. PsuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
RaxDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is RaxDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
RaxDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is RaxDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
RaxDeviceGroup_SuccessfulRecoveryActionPerformedBoardA restart of the whole Device Board or Auxiliary Unit has been performed. RaxDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
RbsSynchronization_NodeSynchronizationRedundancySwitchThis event is issued at successful automatic switch over of distributing Timing Unit to stand- RbsSynchronization
by unit.

The cause of the switch over can be:


The Timing Unit Device supervision indicates loss of synchronisation
A HW failure is detected on the Timing Unit Plug In Unit
The distributing Timing Unit is Dependency Locked by the user
RetuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is RetuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
RetuDeviceGroup_SuccessfulRecoveryActionPerformedBoar A restart of the whole Device Board or Auxiliary Unit has been performed. RetuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
RfifDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is RfifDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
RfifDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is RfifDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
RfifDeviceGroup_SuccessfulRecoveryActionPerformedBoard A restart of the whole Device Board or Auxiliary Unit has been performed. RfifDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
RfifDeviceGroup_SuccessfulRecoveryActionPerformedReestaThis event is sent when there is a short period of gamma link failure. RfifDeviceGroup

Alarm and Event List - Events 43 / 46


APPENDIX: Alarm and Event List - Events

specificEvent Description Managed Object


RfifDeviceGroup_SuccessfulRecoveryActionPerformedSwitchA switching of BB Clock source has been performed. RfifDeviceGroup

All RAX and TX boards always get their BB clock from either the BBIF1 or BBIF2. The clock
source can be switched between these two boards.
RruDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is RruDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
RruDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is RruDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
RruDeviceGroup_SuccessfulRecoveryActionPerformedBoard A restart of the whole Device Board or Auxiliary Unit has been performed. RruDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
RuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is RuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
RuDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is RuDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
RuDeviceGroup_SuccessfulRecoveryActionPerformedBoardRA restart of the whole Device Board or Auxiliary Unit has been performed. RuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
RuifDeviceGroup_ SuccessfulRecoveryActionPerformedReesThis event is sent when there is a short period of gamma link failure. RuifDeviceGroup
RuifDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is RuifDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
RuifDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is RuifDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
RuifDeviceGroup_SuccessfulRecoveryActionPerformedBoardA restart of the whole Device Board or Auxiliary Unit has been performed. RuifDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
SaiuDeviceGroup_SuccessfulRecoveryActionPerformedBoardA restart of the whole Device Board or Auxiliary Unit has been performed. SaiuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
Download of Local AA Database completed The reqested local AA database was successfully installed Security
Download of Local AA Database failed The requested local AA database was not installed Security
Download of Trusted Certificates completed The requested certificate(s) was(were) successfully installed Security
Download of Trusted Certificates failed The requested certificate(s) was(were) not installed. Security
Node Credentials expiring Node Credentials will expire. See attribute, certExpirWarnTime. Security
Node Credentials installed Node Credentials are installed. Security
Node Credentials rolled back The enrollment action has been rolled back, the new credentials have been discarded and theSecurity
credentials used before enrollment started, if any, have been reinstated.
SlotNew PIU detected, matches the defined configuration The new hardware can be used. No reconfiguration was needed, or the node reconfigured Slot
itself automatically.
SlotNew PIU detected, no predefined configuration exist This slot cannot be used. There is no software allocation for the slot. Slot
StrxDeviceGroup_ SuccessfulRecoveryActionPerformedReesThis event is sent when there is a short period of gamma link failure. StrxDeviceGroup
StrxDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is StrxDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
StrxDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is StrxDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
StrxDeviceGroup_SuccessfulRecoveryActionPerformedBoardA restart of the whole Device Board or Auxiliary Unit has been performed. StrxDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
BPDU Guard, Port Blocked Bridge Port Data Unit Guard blocks an Edge Port. SwitchPortStp
BPDU Guard, Port Unblocked Bridge Port Data Unit Guard unblocks an Edge Port. SwitchPortStp
Edge Port Mode transition to EDGE_OFF A port with attribute, edgePortMode set to AUTO_EDGE or ADMIN_EDGE_ON, transits to SwitchPortStp
EDGE_OFF.
Edge Port Mode transition to EDGE_ON A port with attribute, edgePortMode set to AUTO_EDGE or ADMIN_EDGE_ON, transits to SwitchPortStp
EDGE_ON.
STP Role transition to ALTERNATE Spanning Tree Protocol role transits from ROOT to ALTERNATE. SwitchPortStp
STP Role transition to ROOT Spanning Tree Protocol role transits from ALTERNATE to ROOT. SwitchPortStp
NssSynchronization_SynchRefChanged A new reference has been selected as the active reference. Synchronization
NssSynchronization_SystemClockStatusChanged The state of the system clock has changed. Synchronization
PHY_T1Ppt_MI_AUTOLOCK_IND A port is locked. T1PhysPathTerm
PHY_T3Ppt_MI_AUTOLOCK_IND A port is locked. T3PhysPathTerm

Alarm and Event List - Events 44 / 46


APPENDIX: Alarm and Event List - Events

specificEvent Description Managed Object


TrxDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is TrxDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
TrxDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is TrxDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
TrxDeviceGroup_SuccessfulRecoveryActionPerformedBoardRA restart of the whole Device Board or Auxiliary Unit has been performed. TrxDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
TuDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is TuDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
TuDeviceGroup_SuccessfulRecoveryActionPerformedBoardRA restart of the whole Device Board or Auxiliary Unit has been performed. TuDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
TxDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is TxDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
TxDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is TxDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
TxDeviceGroup_SuccessfulRecoveryActionPerformedBoardRA restart of the whole Device Board or Auxiliary Unit has been performed. TxDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.
Creating a Configuration Version Creation of a configuration version has been requested. UpgradePackage
Entering normal mode The upgrade phase is finished and the state of the node is set to normal mode, that is, fault- UpgradePackage
tolerant mode, and the upgrade supervision timer is stopped.
Entering upgrade mode UpgradePackage
The upgrade phase is initiated and the system state is set to upgrade mode: the rollback CV
is created, fault-tolerant mode is set, and the upgrade supervision timer is set.
Executing an application unique trigger An undefined application-specific action is executing. UpgradePackage
Executing trigger Confirmed Confirmation that the node is in a normal state (normally after manual confirmation of the UpgradePackage
upgrade).
Executing trigger Convert Configuration data is converted. UpgradePackage
Executing trigger Execute The switch to new software is to be executed. UpgradePackage
Executing trigger Finish Old loader information and old persistent data are cleaned up. Old programs are also UpgradePackage
removed.
Executing trigger Initiate UpgradePackage
New programs are created, and old programs are prepared for being taken out of operation.
Executing trigger Preload Software that is preloadable is preloaded on device boards. UpgradePackage
Execution of upgrade failed The execution of upgrade failed for some reason. A rollback may occur and the node may UpgradePackage
restart.
Java Virtual Machine (JVM) restart requested A restart of the JVM has been requested. UpgradePackage
Node restart requested A node restart has been requested. UpgradePackage
Node upgrade requested A reboot node upgrade has been requested. A CV is created and is set as startable before UpgradePackage
the node is restarted.
Reboot PIU upgrade requested A reboot PIU upgrade has been requested, that is, one or more PIUs will be restarted. UpgradePackage
Reconfiguring MOs MOs, as defined in the upgrade control file, are reconfigured, for example: PiuType, UpgradePackage
Repertoire, ReliableProgramUniter, PlugInUnit, and SwAllocation.
Soft PIU upgrade requested A soft PIU upgrade has been requested, that is, a number of programs are started, stopped UpgradePackage
or upgraded.
Start or stop of program(s) requested One or more programs are to be started or stopped. UpgradePackage
Upgrade executed The execution of upgrade is finished. UpgradePackage
Upgrade requested An upgrade action has been requested, for example, rebootNodeUpgrade. UpgradePackage
UpgradePackage AUE confirmed with warning An Application Upgrade Engine has confirmed with a warning. UpgradePackage
UpgradePackage AUE failure An Application Upgrade Engine has reported a failure or has not answered within the UpgradePackage
expected time.
UpgradePackage AUE progress Progress indication from an Application Upgrade Engine that is part of the upgrade. UpgradePackage
UpgradePackage Creating a Configuration Version Creation of a configuration version has been requested. UpgradePackage
UpgradePackage Entering normal mode The upgrade phase is finished and the state of the node is set to normal mode, that is, fault- UpgradePackage
tolerant mode, and the upgrade supervision timer is stopped.
UpgradePackage Entering upgrade mode The upgrade phase is initiated and the system state is set to upgrade mode: the rollback CV UpgradePackage
is created, fault-tolerant mode is set, and the upgrade supervision timer is set.

UpgradePackage Executing an application unique trigger An undefined application-specific action is executing. UpgradePackage
UpgradePackage Executing trigger Confirmed Confirmation that the node is in a normal state (normally after manual confirmation of the UpgradePackage
upgrade).
UpgradePackage Executing trigger Convert Configuration data is converted. UpgradePackage
UpgradePackage Executing trigger Execute The switch to new software is to be executed. UpgradePackage
UpgradePackage Executing trigger Finish Old loader information and old persistent data are cleaned up. Old programs are also UpgradePackage
removed.
UpgradePackage Executing trigger Initiate New programs are created, and old programs are prepared for being taken out of operation. UpgradePackage

UpgradePackage Executing trigger Preload Software that is preloadable is preloaded on device boards. UpgradePackage

Alarm and Event List - Events 45 / 46


APPENDIX: Alarm and Event List - Events

specificEvent Description Managed Object


UpgradePackage Execution of upgrade failed The execution of upgrade failed for some reason. A rollback may occur and the node may UpgradePackage
restart.
UpgradePackage Java Virtual Machine (JVM) restart A restart of the JVM has been requested. UpgradePackage
requested
UpgradePackage Node restart requested A node restart has been requested. UpgradePackage
UpgradePackage Node upgrade requested A reboot node upgrade has been requested. A CV is created and is set as startable before UpgradePackage
the node is restarted.
UpgradePackage Reboot PIU upgrade requested A reboot PIU upgrade has been requested, that is, one or more PIUs will be restarted. UpgradePackage
UpgradePackage Reconfiguring MOs MOs, as defined in the upgrade control file, are reconfigured, for example: PiuType, UpgradePackage
Repertoire, ReliableProgramUniter, PlugInUnit, and SwAllocation.
UpgradePackage Soft PIU upgrade requested A soft PIU upgrade has been requested, that is, a number of programs are started, stopped UpgradePackage
or upgraded.
UpgradePackage Start or stop of program(s) requested One or more programs are to be started or stopped. UpgradePackage
UpgradePackage Upgrade executed The execution of upgrade is finished. UpgradePackage
UpgradePackage Upgrade requested An upgrade action has been requested, for example, rebootNodeUpgrade. UpgradePackage
UpgradePackage Verification before execution of upgrade Basic checks are made to make sure that the upgrade can be executed, for example: UpgradePackage
checksum of load-module files, a check that the required number of CVs can be created and
supported, and a check for faulty PIUs.
UpgradePackage Waiting for confirm upgrade The execution of upgrade is halted while waiting for confirmation from the client. UpgradePackage
UpgradePackage Warning: Handling of the final ConfigurationThe handling of the final CV failed. This problem does not cause the upgrade to fail. UpgradePackage
Version failed
UpgradePackage Warning: Unexpected condition detected Unexpected condition detected during execution of the upgrade. This problem does not UpgradePackage
cause the upgrade to fail.
Verification before execution of upgrade Basic checks are made to make sure that the upgrade can be executed, for example: UpgradePackage
checksum of load-module files, a check that the required number of CVs can be created and
supported, and a check for faulty PIUs.
Waiting for confirm upgrade The execution of upgrade is halted while waiting for confirmation from the client. UpgradePackage
Warning: Handling of the final Configuration Version failed The handling of the final CV failed. This problem does not cause the upgrade to fail. UpgradePackage
Warning: Unexpected condition detected Unexpected condition detected during execution of the upgrade. This problem does not UpgradePackage
cause the upgrade to fail.
PHY_Vc12Ttp_MI_AUTOLOCK_IND A port is locked. Vc12Ttp
PHY_Vt1.5Ttp_MI_AUTOLOCK_IND A port is locked. Vt15Ttp
XalmDeviceGroup_HardwareTestEndIndication When a hardware test is manually initiated, an event notification is sent when the test is XalmDeviceGroup
complete.

Additional information given:


Result: Passed, Failed or Undetermined
Test Time: Test execution time in seconds
XalmDeviceGroup_PreloadFailed When upgrading the SW in an RBS, if any Load Module should fail to preload, an event is XalmDeviceGroup
generated for each failed preloading of a Load Module to an Auxiliary Processor or Device
Processor
XalmDeviceGroup_SuccessfulRecoveryActionPerformedBoarA restart of the whole Device Board or Auxiliary Unit has been performed. XalmDeviceGroup

The purpose is to restore the unit's HW and SW. A limited HW test is performed as a part of
the restart.

Alarm and Event List - Events 46 / 46

Vous aimerez peut-être aussi