FULL-FLOW Full flow roof & floor outlets,

rainwater drainage system that

OUTLETS
are engineered for flat roof,
parking bays, paved areas
and walkways to ensure a leak
proof drainage system.
FULL-FLOW OUTLETS

180 VERTICAL ROOF OUTLET - CENTRE BOLT

PROD
NO. DN A B C D E F G OUTLET MASS TYPE

3500 80 105 55 300 160 69 38 102 THREADED 7.2 DOME

3505 100 125 85 350 205 75 32 130 THREADED 11 DOME

3800 80 105 - 300 160 69 32 102 THREADED 7.2 FLAT

3805 100 125 - 350 207 75 32 130 THREADED 11 FLAT


NOTE: ALL GRATINGS MANUFACTURED FROM
UNBREAKABLE DUCTILE IRON
FULL-FLOW OUTLETS

180 VERTICAL ROOF OUTLET - EARED

PROD
NO. DN A B C D E F G OUTLET MASS TYPE

3530 150 150 - 375 205 11 71 180 THREADED 16.5 DOME

3830 150 150 - 375 - 11 71 180 THREADED 16.5 FLAT


NOTE: ALL GRATINGS MANUFACTURED FROM
UNBREAKABLE DUCTILE IRON
FULL-FLOW OUTLETS

90 SIDE ROOF OUTLET - CENTRE BOLT

PROD
NO. DN A B C D E F OUTLET MASS TYPE

3579 80 131 55 300 160 71 31 THREADED 7.2 DOME

3585 100 170 85 350 205 97 42 THREADED 11.5 DOME

3590 150 207 85 363 205 121 30 THREADED 16.6 DOME

3879 80 131 - 300 160 71 31 THREADED 7.2 FLAT

3885 100 170 - 350 207 97 42 THREADED 11.5 FLAT

3890 150 2-7 - 363 207 121 30 THREADED 16.6 FLAT


NOTE: ALL GRATINGS MANUFACTURED FROM
UNBREAKABLE DUCTILE IRON
FULL-FLOW OUTLETS

45 SIDE ROOF OUTLET - EARED

PROD
NO. DN A B C D E F G OUTLET MASS TYPE

3570 100 193 85 375 205 60 71 145 THREADED 16.4 DOME

3870 100 193 - 375 205 60 71 145 THREADED 16.4 FLAT


NOTE: ALL GRATINGS MANUFACTURED FROM
UNBREAKABLE DUCTILE IRON
FULL-FLOW OUTLETS

TWO-WAY ROOF OUTLET - CENTRE BOLT


FULL-FLOW OUTLETS

TWO-WAY ROOF OUTLET - CENTRE BOLT

PROD
NO. DN A B C D E F G H I OUTLET MASS

3540 80 194 300 200 63 67 32 32 135 104 THREADED 8.9

3550 100 194 300 200 63 67 32 32 135 130 THREADED 9.2


NOTE: ALL GRATINGS MANUFACTURED FROM
UNBREAKABLE DUCTILE IRON
FULL-FLOW OUTLETS

FLAT GRATES FOR CAR PARK AND BALCONY

PROD NO. SIZE TYPE A B C

SEE 75 CENTREBOLT 160 14 -

CORRESPONDING 100/150 CENTREBOLT 207 15 -

OUTLETS 100/150 EARED 190 18 33


NOTE: ALL GRATINGS MANUFACTURED FROM
UNBREAKABLE DUCTILE IRON
DESIGN POCEDURE

Roof outlet: Select type of outlet from available range

Rain area: Identify applicable graph

Risk assessment: Determine potential damage that could be caused by an excessive


rainwater downpour:

No damage. Use Q5 (5-year recurrence interval graph)

Moderate damage, choose point between Q5 and Q100

Substantial damages, use Q100 graph

No damage allowed, refer to consulting engineer

DESIGN CRITERIA

Graphs allow for build-up of rainwater at outlet up to 100mm deep. Ensure that Waterproofing
can withstand head.

Although the above information has been simplified it is correct to the best of our knowledge.
Various factors may, however, influence the discharge and Saint-Gobain

Pipelines will not be held responsible for any claims. Refer to a consulting engineer if required.
This design information is only applicable to
FULL-FLOW roof outlets

Reference of Document:
1. Scwarts and Cullinan.
Roof drainage of large buildings in South Africa
2. Van Heerden. Vloedvoorspellings en gebou stormwater
www.saint-gobain-pipelines.co.za
Cape Town

Tel: +27(0)21 905 3621

Fax: +27(0)21 905 1996

e-mail: cape.town@saint-gobain-pipelines .co.za

Durban

Tel: +27(0)31 700 8835 / 36

Fax: +27(0)31 700 8314

e-mail: durban@saint-gobain-pipelines .co.za

Port Elizabeth

Tel: +27(0)041 451 3556

Fax: +27(0)041 451 3558

e-mail: pe@saint-gobain-pipelines .co.za

Saint-Gobaian Pipelines South Africa

275 Stephenson Road

Pretoria West

PO Box 2462

Pretoria 0001 RSA

Tel: +27(0)12 380 4600


Fax: +27(0)12 386 2664

e-mail: sales@saint-gobain-pipelines .co.za